S-302.pdf

PDF 396 KB Posted

Attached to
FY16 DODEA PN AM0033 Replace Elementary School Federal contract opportunity
Solicitation number
W912DS-16-R-0010
Issued by
Department of the Army Corps of Engineers Engineering District New York

About this file

Amendment 0008 S-302

View the file

Other files for this federal contract opportunity

Other files attached to FY16 DODEA PN AM0033 Replace Elementary School, newest first.
File Type Posted
DS-16-R-0010-0009.pdf PDF
A-602.pdf PDF
S-104.pdf PDF
A-123.pdf PDF
A-105.pdf PDF
2016-08-03_WPES_Amend_6_Submittal_Volume1C.pdf PDF
A-413.pdf PDF
2016-08-03_WPES_Amend_6_Submittal_Volume_1B.pdf PDF
W912DS-16-R-0010-0007_(2).pdf PDF
32_31_13_CHAIN_LINK_FENCES_AND_GATE.pdf PDF
27_51_16_PUBLIC_ADDRESS_AND_MISCELLANEOUS_AUDIO_VIDEO_SYSTEMS.pdf PDF
DELETE_Section_09_67_23.13_STANDARD_RESINOUS_FLOORING.pdf PDF
23_70_03.00_10_HEATING_AND_UTILITIES_SYSTEMS _CENTRAL_STEAM.pdf PDF
32_18_16.13_PLAYGROUND_AND_PROTECTIVE_SURFACING.pdf PDF
23_07_00_THERMAL_INSULATION_FOR_MECHANICAL_SYSTEMS.pdf PDF
23_05_15_COMMON_PIPING_FOR_HVAC.pdf PDF
06_61_16_SOLID_POLYMER_(SOLID_SURFACING)_FABRICATIONS.pdf PDF
23_52_00_HEATING_BOILERS.pdf PDF
09_67_23.14_CHEMICAL_RESISTANT_RESINOUS_FLOORING.pdf PDF
23_09_23_LONWORKS_DIRECT_DIGITAL_CONTROL_FOR_HVAC_AND_OTHER_BUILDING_CONTROL_SYSTEMS.pdf PDF
05_40_00_COLD-FORMED_METAL_FRAMING.pdf PDF
2016-08-03_WPES_Amend_6_Submittal_Volume_2B.pdf PDF
2016-08-03_WPES_Amend_6_Submittal_Volume_1A.pdf PDF
2016-08-03_WPES_Amend_6_Submittal_Volume_1B.pdf PDF
2016-08-03_WPES_Amend_6_Submittal_Volume1C.pdf PDF
SWPPP_Final.pdf PDF
Pages_from_New_Elementary_School_-_Geotech_Report.pdf PDF
DPW_Equipment_Inventory_Amendment6.xlsx XLSX spreadsheet
W912DS-16-R-0010-Amendment_0006.pdf PDF
Amendment_0006_Q A.pdf PDF
W912DS-16-R-0010-0005.pdf PDF
site_visit_Sign_in_Sheet.pdf PDF
J A_Name_Brand_USMA_West_Point_Elem_School_Redacted.pdf PDF
A-107_LEVEL_1_-_UNIT_C_FLOOR_PLAN.pdf PDF
A-108_LEVEL_1_-_UNIT_D_FLOOR_PLAN.pdf PDF
A-812_SIGNAGE_ELEVATIONS_AND_DETAILS.pdf PDF
A-609_ALUMINUM_CURTAINWALL_ELEVATIONS.pdf PDF
A-811_SIGNAGE_ELEVATIONS_AND_DETAILS.pdf PDF
R-0010_Site_Visit_Location.pdf PDF
Amendment_1___A-720_-_ROOM_FINISH_SCHEDULE_-_LEVEL_1.pdf PDF
Amendment_1___A-421_-_LEVEL_1_-_UNIT_A_EQUIPMENT_PLAN.pdf PDF
Amendment_1___Fire_Alarm_Drawings_REV1_-1.pdf PDF
Amendment_1___A-428_-_CASEWORK_PLANS_AND_DETAILS.pdf PDF
W912DS-16-R-0010_SOLICITATION_Amendment_0001.pdf PDF
2016-08-03_WPES_RTA_Submittal_Volume_1.pdf PDF
WPES_Specs_VOL_1_Revised.pdf PDF
W912DS-16-R-0010_SOLICITATION.pdf PDF
WPES_Specs_VOL_2.pdf PDF
2016-08-03_WPES_RTA_Submittal_Volume_2.pdf PDF
2016-08-03_WPES_RTA_Civil_Bid_Option_Sheets.pdf PDF
Show all 50

FY16 DODEA PN AM0033 Replace Elementary School has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1' - 4" 1"

F.O. CMU

F.O. BUILDING

FINISHED GRADE -

SEE CIVIL DWGS.

INSULATION - SEE ARCH. DWGS.

VENEER MASONRY -

SEE ARCH. DWGS.

4" CMU

FILL SOLID WITH GROUT

BELOW FLOOR

TOP OF FOOTING

EL. - SEE PLAN

3" CLR. (TYP.)

8" CMU

VERT. WALL REINF. - SEE

'MASONRY WALL REINFORCING

PLAN' ON SHEET S-010

MORTAR COLLAR JOINT SOLID

BELOW FLOOR

FOOTING - SEE PLAN

AND SCHEDULE

0" (TYP.)

GRID

CL COLUMN BEYOND

CURTAINWALL -

SEE ARCH. DWGS.

CONT. BOND BREAKER

FINISHED FLOOR

EL. - SEE PLAN

SLAB-ON-GRADE

1 1/2" CLR. W.W.F.

POROUS FILL

VAPOR RETARDER

CONT. 16" CMU BOND

BEAM REINF. WITH

2 - #5 TOP AND BOTTOM

CURTAINWALL SUPPORT

ANGLE - SEE DETAILS

ON SHEET S-202 AND

THE ARCH. DWGS. FOR

ADDITIONAL INFORMATION WALL

BEYOND DOOR - SEE ARCH. DWGS. FOR

EXACT SIZE AND LOCATION

SEE 'TYPICAL SLAB-ON-GRADE

DETAILS' FOR ADDITIONAL

REINFORCING AT EXTERIOR

DOORS ON SHEET S-501

(TYP.)

SEE ARCH. DWGS.

1' - 4"

F.O. CMU BELOWF.O. BLDG.

FOR DETAILS

NOT NOTED SEE

SECTION C1/S-302

THERMAL SEPARATION

MATERIAL - SEE ARCH. DWGS.

1 1/2"

EXTERIOR

SLAB - SEE

CIVIL DWGS.

CL HEADED

STUD

REINFORCING -

SEE PLAN

SLOPE

1/4" : 1'-0"

(TOP OF SLAB)

CONT. GALV.

PL5/16x3 1/2 w/ 3/4"Ø x 6"

LONG HEADED

STUD AT 16"o/c

8" CMU -

GROUT SOLID

(TYP.)

8"

CONT. GALV. PL5/16x7 w/ 3/4"Ø x 6" LONG HEADED STUD AT 16"o/c

8" MIN.

FROST SLAB -

SEE PLAN

FINISHED GRADE -

SEE CIVIL DWGS.

TOP OF RETAINING

WALL

CONT. 3/4"

CHAMFER (TYP.)

RAILING AND RAILING

INSERTS (NOT SHOWN) -

SEE ARCH. DWGS.

TOP OF SLAB

EL. - SEE CIVIL DWGS.

#5 AT 12"o/c

CONT. HORIZ.

WATERPROOFING AND

DRAINAGE SYSTEMS -

SEE ARCH. DWGS.

8" CONCRETE

WALL

RETAINING WALL FOOTING - SEE

PLAN AND SCHEDULE FOR

DIMENSIONS AND THICKNESSES

3" CLR.

(TYP.)

2" CLR.

TOP OF FOOTING

EL. - SEE PLAN

LA

P

S P

LI

C

E

#5 AT 12"o/c

VERT. (MIDDLE OF WALL)

SLAB - SEE

CIVIL DWGS. (TYP.)

#5 AT 24"o/c TOP

3 - #5 CONT.

BOTTOM

7 - #5 CONT.

TOP

#4 x 3'-0" WITH STD. 90 DEG. HOOK AT 12"o/c

1 - #4 CONT.)

10" CMU

CONT. 16" CMU BOND

BEAM REINF. WITH

2 - #5 TOP AND BOTTOM

1' - 2"

FOR DETAILS

NOT NOTED SEE

SECTION C1/S-302

EL. - SEE ARCH. DWGS. CHAIN LINK FENCE -

SEE ARCH. DWGS.

4" CMU

HSS - SEE PLAN

HSS POST - SEE PLAN

AND ARCH. DWGS.

2 - 3/4" ADHESIVE ANCHORS (8" EMB.)

GALV. Pc L3 1/2x3 1/2x5/16 x 0'-6" AT 12"o/c VERT.

B.O. HSS

EL. - SEE ARCH. DWGS.

FOR DETAILS

NOT NOTED SEE

SECTION C1/S-302

CONT. 8" CMU BOND

BEAM REINF. WITH

2 - #5 BOTTOM

1' - 4"

8" CMU

4" CMU4" CMU

EL. - SEE ARCH. DWGS.

10" CONCRETE WALL

EL. - SEE PLAN

CHAIN LINK FENCE -

SEE ARCH. DWGS.

1' - 2"

14" CONCRETE WALL

WATERPROOFING AND

DRAINAGE SYSTEMS -

SEE ARCH. DWGS.

RETAINING WALL

FOOTING - SEE PLAN

AND SCHEDULE

DOVETAIL SLOTS FOR

MASONRY ANCHORS

FOR DETAILS

NOT NOTED SEE

SECTION A1/S-302

#4 AT 12"o/c

CONT. HORIZ.

#5 AT 12"o/c VERT.

EACH FACE

11 - #5 CONT. TOP

#7 AT 24"o/c TOP

4 - #5 CONT. BOTTOM

B.O. HSS

FOR DETAILS

NOT NOTED SEE

SECTION C1/S-3.02

FINISHED FLOOR

EL. - SEE PLAN

EXIST. VENEER

MASONRY

EXIST. CMU WALL

EXIST. CONC.

SLAB-ON-GRADE

EXIST. CONC.

WALL FOOTING

EXIST. CONC.

FOUNDATION WALL

B.E.J. VARIES -

SEE PLAN

SEE PLAN

M

IN

#5 AT 12"o/c CONT.

HORIZ. T. AND B.

#5 WITH STD. 90° HOOK

AT 12"o/c T. AND B.

IN-PLACE MICROPILE

FOR DETAILS

NOT NOTED SEE

SECTIONS C1/S-302

AND C3/S-302

8" CONCRETE WALL

6' - 0"

1'

2"

2" CLR.

3" CLR. (TYP.)

#4 AT 8"o/c

CONT. HORIZ.

#5 AT 6"o/c

T. AND B.

B.E.J. VARIES -

SEE PLAN(E) F.O. BLDG.

ABOVE

#6 AT 8"o/c M.O.W.

#5 AT 12"

CONT. HORIZ.

THE INFORMATION REGARDING THE

EXISTING CONSTRUCTION WAS

OBTAINED FROM THE RECORD

DRAWINGS PREPARED BY QUINLIVAN,

PIERIK & KRAUSE DATED APRIL 28,

2000. ALL INFORMATION SPECIFYING

EXISTING CONDITIONS MUST BE

VERIFIED BY THE GENERAL

CONTRACTOR. THE

AFOREMENTIONED DRAWINGS WILL

BE MADE AVAILABLE TO THE

CONTRACTOR UPON REQUEST.

SPEIGHT, MARSHALL

& FRANCIS, P.C.

STRUCTURAL ENGINEERS

2125 McCOMAS WAY. SUITE 103 VIRGINIA BEACH VA. 23456

PHONE (757) 427-1020 WWW.SMANDF.COMFAX (757) 427-5919

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A 1909 CYPRESS AVENUE

VIRGINIA BEACH, VA 23451

(757) 417 - 0140

1 2 3 4 5

/4

/2

:5 :4

P

M

579153

S-302

S E

C T

IO

N

S

W E

S T

P O

IN

T

E L E

M E

N T

A R

Y S

C H

O O

L R

E P

L A

C E

M E

N T

U S

M A

W

E S

T P

O

IN

T N

E W

Y O

R K

N E

W Y

O R

K N

Y

W A

L L E

R T

O D

D

S A

D D

L E

R A

R C

H

IT

E C

T S

C

Y P

R E

S S

A V

E N

U E

V

IR

G

IN

IA

B

E A

C H

V

A

J S

C

R P

F

S M

F

D W

S

A

U G

U S

T

3 AUGUST 2016

3/4" = 1'-0"S-101

C1 SECTION

3/4" = 1'-0"S-101

C2 SECTION

3/4" = 1'-0"S-109

C4 SECTION

3/4" = 1'-0"S-105

C3 SECTION

FOR DETAILS

NOT NOTED SEE

SECTION C3/S-302

3/4" = 1'-0"S-104

A1 SECTION

3/4" = 1'-0"S-101

B3 SECTION

3/4" = 1'-0"S-101

A2 SECTION

3/4" = 1'-0"S-105

B4 SECTION

3/4" = 1'-0"S-302

A3 SECTION

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

D E L

E T E

D

FROM A

RT

COURTYARD

R

E V

IS

IO

N

/2 7/

File details come from the government source that posted it. Updated .