A-811_SIGNAGE_ELEVATIONS_AND_DETAILS.pdf
PDF 564 KB Posted
- Attached to
- FY16 DODEA PN AM0033 Replace Elementary School Federal contract opportunity
- Solicitation number
- W912DS-16-R-0010
About this file
W912DS-16-R-0010 A-811 SIGNAGE ELEVATIONS AND DETAILS
View the file
Other files for this federal contract opportunity
Show all 50
FY16 DODEA PN AM0033 Replace Elementary School has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TYPE A TYPE B TYPE C TYPE D
TYPE E TYPE F
TYPE K
TYPE H
TYPE J
TYPE G
MAXIMUM
OCCUPANCY
XXX
TYPE O
8"
8"
10"
TYPE L
TYPE N
8"
8" 8" 8"
1' - 0"
/2
11"
11"
/2
TYPE M
TYPE P1
8"
11"
/2
810810
TYPE P TYPICAL
2' - 4"
TYP EVACUATION INSERT
BUILDING SYSTEMS
Structural Beam
Exhaust Air
Supply Water
Return Water
Fire Protection
Supply Air
Cable Tray
The piping and ducts above the ceiling carry air and water to the building.
The beams help hold up the building. The cable trays carry internet and phone lines around the school.
LOOK UP!
SIGN HEADING
1' - 1 1/2" 1/4" 8" 1/4" 6"
5"
DIAGRAM OR IMAGE
/8
/4
/8
/8
1/8" 1' - 2 3/4" 1/8" 5/8"
835 836
836836
SEE TYPICAL FOR DIMENSIONS
837838 837
TYPE P2
TOPOGRAPHY
The thick curvy lines you see at your feet show the elevation, or height, of the ground before this school was built!
LOOK AT
YOUR FEET!
829829
836836
SEE TYPICAL FOR DIMENSIONS
840841
841841841841841841
841841
+0"
+9/16"
+8/16"
+7/16"
+6/16" +4/16"
+3/16"
+2/16"
+1/16"
+5/16"
RESTROOM
RESTROOM
GIRLS 2537 BOYS 2537 STAIRS 2537
EMERGENCY
IN CASE OF FIRE
USE STAIRS
DO NOT USE ELEVATORS
ROOM NAME
ROOM NAME
EVACUATION MAP
DIRECTORY
MUSIC STUDIO
ELEVATOR
STAIRS
MULTI-PURPOSE ROOM1
9"
4"
DAVID P. ISBELL A
I
N I
G
RI
V
FOHTLAE
W
N O
M M
O C
No.
ARCH TI ECT
US Army Corps of Engineers ®
SHEET OF
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S D
R A
W N
B Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A 1909 CYPRESS AVENUE
VIRGINIA BEACH, VA 23451
(757) 417 - 0140
1 2 3 4 5
/1
/2
:4
:5
P
M C
R e v it
\1 -A
W P
E S
A
R C
H jt o ro
-s p ri n g s .r v t
579350
A-811
S
IG
N A
G E
E L E
V A
T
IO
N S
A N
D D
E T
A
IL
S
W E
S T
P O
IN
T
E L E
M E
N T
A R
Y S
C H
O O
L R
E P
L A
C E
M E
N T
N E
W Y
O R
K N
Y
W A
L L E
R T
O D
D
S A
D L E
R A
R C
H
IT
E C
T S
C
Y P
R E
S S
A V
E N
U E
V
IR
G
IN
IA
B
E A
C H
V
A
F E
B
M M
T
W T
S
W W
S
A
U G
U S
T
-A
3 AUGUST 2016
3" = 1'-0"
SIGNAGE LEGEND
0 1" 6" 9"2" 3" 4" 5" 1'
3"=1'-0"
GRAPHIC SCALE
SHEET KEYNOTES
801 1/8" CLEAR MATTE ACYRLIC,
SUBSURFACE PAINTED
804 RAISED SYMBOLS
805 BRAILLE
806 EXTERIOR SIGN
807 WINDOW INSERT FOR EVACUATION
ROUTE. SEE TYPICAL EVACUATION
INSERT DETAIL ON THIS SHEET.
808 RAISED TEXT, SIZE 1-1/4"H
809 RAISED TEXT, SIZE 5/8"H
810 1 1/2" TALL INSERT WINDOW FOR
CHANGEABLE PAPER INSERTS BY
CUSTOMER
811 RAISED TEXT, SIZE 1-1/2" H
812 RAISED TEXT, SIZE 1" HIGH
828 PROVIDE AN EVACUATION MAP ON
8 1/2" X 11" WHITE PAPER FOR
EACH TYPE K SIGN LOCATION.
TURN COMPUTER FILE OVER TO
SCHOOL ADMINISTRATION.
INFORMATION FOR EXIT PATHS
SHALL BE COORDINATED WITH THE
SCHOOL ADMINISTRATION AND THE
WEST POINT FIRE DEPARTMENT.
829 COLOR TO MATCH PAINT COLOR
P-3.
830 COLOR TO MATCH PAINT COLOR
P-1.
831 WHITE ARIAL TEXT, 1" H
832 WHITE ARIAL TEXT, 1/2" H
833 BLACK ARIAL TEXT, 1/2" H
834 WHITE ARIAL TEXT, 3/4"H
835 IMAGE TO BE REVISED AND
PROVIDED AFTER SYSTEMS HAVE
BEEN INSTALLED.
836 COLOR OF SHAPE TO BE WHITE.
PROVIDE DROP SHADOW AROUND
SHAPE.
837 BACKGROUND TO MATCH PAINT
COLOR P-1 WITH BLACK ARIAL
TEXT OR P-3 WITH WHITE ARIAL
TEXT. IF OPTIONAL ADDITIONAL
CURVE IS USED, A COMBINATION
OF THE TWO COLOR SCHEMES MAY
BE USED.
838 OPTIONAL ADDITIONAL CURVE TO
BE WHITE WITH A DROP SHADOW
AROUND SHAPE, IF USED.
839 NEUTRAL COLORED MAP SHOWING
TOPOGRAPHY LINES- "TOPO MAP"
FROM USGS TOPOGRAPHY MAP OF
SCHOOL SITE
840 AREA COLORED TO MATCH PAINT
COLOR P-3. AREA SHALL BE FLAT
AND EVEN WITH REST OF SIGN.
841 AREA COLORED TO MATCH PAINT
COLOR P-3 AND RAISED 1/16"
ABOVE AREA LOCATED TO ITS
RIGHT.
GENERAL SIGNAGE NOTES
NOTE: THESE GENERAL NOTES APPLY TO ALL SIGNAGE PLANS
A PROVIDE NO SMOKING DECAL ON GLASS AT EACH ENTRANCE
DOOR.
B REFER TO TYPICAL SIGN MOUNTING HEIGHT ELEVATION FOR
INSTALLATION LOCATION OF SIGNS.
C PROVIDE MALE, FEMALE, AND HANDICAP SYMBOL FOR UNISEX
STAFF RESTROOMS.
D PROVIDE BOY, GIRL, AND HANDICAP SYMBOL FOR UNISEX STUDENT
RESTROOMS.
E PROVIDE BOY, AND HANDICAP SYMBOL FOR BOY'S GROUP
RESTROOM.
F PROVIDE GIRL AND HANDICAP SYMBOL FOR GIRL'S GROUP
RESTROOM.
G PROVIDE AN EVACUATION SIGN, TYPE K, IN EACH CLASSROOM
ADJACENT TO DOOR FRAME.
H PROVIDE AN OPAQUE BACK PANEL ON THE INTERIOR SIDE OF THE
ROOM IN LOCATIONS WHERE SIGNS ARE MOUNTED ON GLASS.
BACK PANEL TO BE THE SAME SIZE, MATERIAL AND COLOR OF
ROOM SIGNS.
I SIGNAGE TEXT SHOULD BE COORDINATED WITH END USER BEFORE
FABRICATION.
J ALL TEXT SIZE SHOULD BE 5/8" UNLESS NOTED OTHERWISE.
K PLACEMENT AND MOUNTING HEIGHT OF ALL SIGN TYPE P AND R
SHALL BE VERIFIED AND APPROVED PRIOR TO INSTALLATION.
L ALL SIGNS ARE TO BE CONSTRUCTED OF ACRYLIC PLASTIC,
UNLESS NOTED OTHERWISE. SIGN TYPES P AND R ARE TO BE
DIGITALLY PRINTED ON ACRYLIC PLASTIC.
1/2" = 1'-0"
TYP SIGNAGE INSTALLATION
THE REMAINING TYPE P SIGNS SHALL USE
THE SIGN TYPE P TYPICAL WITH
INFORMATION TO BE PROVIDED. THE
SUBJECT MATTER SHALL BE AS FOLLOWS:
P3 - ART WALL
P4 - HUDSON VALLEY
P5 - DAYLIGHTING
P6 - SOLATUBES
P7 - SOLAR HOT WATER PANELS
P8 - WIND TURBINE AND PHOTOVOLTAIC
PANELS- COW
P9 - MECHANICAL ROOM
P10 - STORM WATER
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
/0
/2
| Sheets |
| A-811 - SIGNAGE ELEVATIONS AND DETAILS |
File details come from the government source that posted it. Updated .