Amendment 0006.pdf

PDF 818 KB Posted

Attached to
Muns Maintenance Storage Facility
Solicitation number
W912DQ20R4003
Issued by

About this file

This is an amendment to a solicitation for construction services. The amendment provides changes to plans and specifications for maintenance facility construction at Whiteman Air Force Base in Missouri. It extends the response due date from March 30, 2020 to May 7, 2020 at 11:00 AM local time. The amendment replaces various plan sheets and drawings. It also replaces the price proposal table. The solicitation is seeking a complete and integrated electronic security system compatible with the base's central monitoring system. The Department of the Army Corps of Engineers Engineering District Kansas City is the issuing agency.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

MUNS Maintenance Facility at Whiteman AFB, Missouri.

The purpose of this amendment is to add changes to the plans and specif ications, and to extend the due date.

See SF 30, Block 14 Continuation Page.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 5

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 29-Apr-2020

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912DQ20R4003

X 9B. DATED (SEE ITEM 11)

27-Feb-2020

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO.

5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

29-Apr-2020

CODE

USACE, KANSAS CITY +

FEDERAL BLDG. CT-M RM 647; 601 E 12TH ST

KANSAS CITY MO 64106-2896

W912DQ 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912DQ20R4003

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE (SF 30)

The following have been added by full text:

AMENDMENT-0006

The SOLICITATION is amended as follows:

NOTE: Deleted text is shown in RED with strikethrough. Added text is shown in GREEN with underline.

1. SPECIFICATIONS:

The following paragraph has changed:

Section 01 11 00 – Summary of Work

Delete Section 01 11 00 in its entirety and replace with 01 11 00 Updated.

Add Munitions MX CSP Version 1 document as an attachment to the 01 11 00 specification.

Section 07 61 14.00 20 – STEEL STANDING SEAM ROOFING Paragraph 2.1 – Roofing Panels

Sheets must provide not less than 12 inches of coverage (width) in place. Provide panels with a minimum corrugation height of 2.25 1.5 inches (nominal). Make provisions for expansion and contraction at either ridge or eave, consistent with the type of system to be used.

- Paragraph 2.6 – Underlayment for Wood Subtrates

ASTM D22/D226M, Type perforated, covered by water-resistant rosin sized building paper.

ASTM E84/ASTM, E96/E96M, Provide a highly permeable self – adhered roofing underlayment air barrier.

Section 03 45 00 – PRECAST ARCHITECTUAL CONCRETE Paragraph 2.4.7.3 – Exposed Aggregate Finish

Delete Paragraph 2.4.7.3 in its entirety.

Section 08 33 23 - OVERHEAD COILING DOORS Paragraph 2.2.1.2 – Insulated Curtain

Form Curtains from manufacturer's standard shapes of interlocking slats. Supply slat system with a minimum R-value of 4 when calculated in accordance with ASHRAE FUN IP. Slats to consist of a urethane core not less than 11/16-inch thick, completely enclosed within metal facings. Ensure the exterior face of slats are the same gauge as specified for curtains. Select an interior face not lighter than 0.0219-inches. The insulated slat assembly requires a flame spread rating of not more than 25 and a smoke development factor of not more than 50 when tested in accordance with ASTM E84.

Section 08 36 13 – SECTIONAL OVERHEAD DOORS Paragraph 2.4.1.1- Insulated Sections

Change the “U” Factor to 0.013605. Delete 27

Section 12 51 00.00 23 – FURNITURE, FIXTURES, AND EQUIPMENT (FF&E) REQUIREMENTS Paragraph 2.4.2.2 -

Change 20 amp to 15 amp

Section 12 51 00.00 23 - FURNITURE, FIXTURES, AND EQUIPMENT (FF&E) REQUIREMENTS Paragraph 2.4.2.1- Panels

D. 6: Change 4 knockouts to 3 knockouts

Section 28 10 05 – ELECTRONIC SAFETY AND SECURITY Paragraph 2.1- Electronic Security Systems (ESS)

Remove:

Provide a complete and integrated electronic security system (ESS) that the meet requirements within. ESS must be compatible with the Installation's central monitoring system and monitored at the Installation central monitoring station. ESS consisting of the following subsystems and features:

Replace:

Provide a complete and integrated electronic security system (ESS) that the meet requirements within. ESS must be compatible with the Installation's central monitoring system and monitored at the Installation central monitoring station. The system shall be capable of working when the connection between the Central Station and facility is lost. This failure to communicate will be reported to both the Central Station and local interface equipment. The Central Station shall be capable of monitoring the ACS, IDS, and CCTV at any time. This system shall be able to report all alarms, send status reports, and CCTV feed to the Base Central Station. In general when the facility is unoccupied the system will report all alarms and change in status to the Central Station. When the facility is occupied only alarms related to the doors will be reported as an alarm. ESS consisting of the following subsystems and features

2. DRAWINGS:

The purpose of this amendment is to exchange Plan Sheets/Drawings for the following:

A. Replace the Plan Sheet IN700 with attached.

B. Replace the following Schedule Sheet A-600 with attached.

C. Replace Plan Sheet A-600_A-601 with the attached.

D. Replace the following Plan Sheet ES101 with attached.

E. Replace the following Plan Sheet A-620 with attached.

F. Replace the following Plan Sheet A-511 with attached.

G. Replace the following Plan Sheet A-510 with attached.

H. Replace the following Plan Sheet A-550 with attached.

I. NARRATIVE CHANGE to Sheet FX100 – Delete and Replace:

5. ALL SPRINKLER PIPING SHALL BE PITCHED FOR DRAINAGE OF

SYSTEM.

PROVIDE AND INSTALL DRAIN VALVES AND WASTE LINES FOR ALL SPRINKLERS AS

REQUIRED BY CODE. DAYLIGHT WASTE LINE WITH A SPLASH BOX TO THE REAR OR SIDES

OF THE BUILDING. MULTIPLE DRAINS MAY BE NECESSARY DUE TO ELEVATION CHANGES.

5. PROVIDE AND INSTALL DRAIN VALVES AND WASTE LINES FOR ALL

SPRINKLERS AS REQUIRED BY CODE. DAYLIGHT WASTE LINE WITH A

SPLASH BOX TO THE REAR OR SIDES OF THE BUILDING. MULTIPLE DRAINS

MAY BE NECESSARY DUE TO ELEVATION CHANGES.

J. Replace the following Plan Sheet S-330 with attached.

K. Replace the following Plan Sheet S-331 with attached.

3. PRICE PROPOSAL:

See attached Price Proposal Table.

4. TIME: Date and Time for receipt of Proposals is changed to May 7, 2020, at 11:00AM local time.

5. AMENDMENT: Offerors are required to acknowledge receipt of this amendment on the Bidding Form in the space provided. Failure to acknowledge all amendments may cause rejection of the bid.

6. TERMS AND CONDITIONS: All other terms and conditions remain unchanged and in full force.

The following have been deleted:

AMENDMENT-0005

SECTION 00 10 00 - SOLICITATION

The required response date/time has changed from 30-Mar-2020 10:00 AM to 07-May-2020 11:00 AM.

(End of Summary of Changes)