W912BU20B0001_Dwgs-AM1.pdf
PDF 5 MB Posted
- Attached to
- AFMES Warehouse Addition/Alteration, Dover Air Force Base, Delaware Federal contract opportunity
- Solicitation number
- W912BU20B0001-0001
About this file
This solicitation package includes drawings and specifications for an addition and alteration project at an Armed Forces Medical Examiner System facility located at Dover Air Force Base in Delaware. The project scope involves renovations to an existing warehouse including new interior finishes, mechanical and electrical systems, furniture, and signage. The solicitation was issued by the U.S. Army Corps of Engineers Philadelphia District and has a bid opening date of June 18, 2020 at 1:00 PM EDT, with bids due on https://safe.apps.mil/ by 11:00 AM EDT to allow for download before public reading. Late bids submitted after the amended deadline will not be considered.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912BU20B0001_AFMES_Bid Abstract_OF 1419.pdf | ||
| W912BU20B0001_Specs-AM1.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
FEC
FEC
F E
FE
FEC
F
E C
FEC
A-201
K L N P R S TK.5
18.7
M.5 N.3L.9
13.9
18.2
EXISTING
INDUSTRIAL
SPACE
ALIGN
/4
27' - 2" 35' - 3"
A
1000C
D
162A
B
6'
0"
4'
C
LE
A R
12' - 2"
1AS.4
1A1.4 1A1.4
1AS.4
15.5
15.8
M.8 P.2
A-301
A-301
14.3
A-301
A-301
CLEAR ZONE
CLEAR ZONE
1A1.6
9.
22.01
5.01
6.01
"7.05
7.05 3
A-311
10.01
10.01
B
1A0.6
1A0.6
12' - 3"
ALIGN
1A0.3b 1A0.3b
E
1000F
7A
3A0.2
1.04
8'
1AS.6
10.01
5.01
5.015.01
4'
6"
2' - 5"
11.04
EXISTING DIESEL
FUEL TANK
EXISTING
GENERATOR
A-301
A-301
1A1.4
1A1.6 1A1.6 1A1.6 1A1.6
RECEIVING/
RECEPTION
157A
A-501
A-201
7.05
7.05
N.2
7' - 1" 4' - 10" 17' - 6" 10' - 0" 25' - 3" 2' - 6" 16' - 0"
M.2 M.4
10.05
TR
EXIST.
CORRIDOR
EXIST.
STAGING
EXIST. GAS
CYLINDER
EXIST. FIRE
PUMP
EXIST.
LOUNGE
119A
EXIST.
CORRIDOR
EXIST.
RECEIVING &
TRANSPORT
157B
EXIST. HAZ.
MAT.
STORAGE
161B
EXIST. HAZ.
MAT.
STORAGE
161A
EXIST. ELEV.
MACH. RM.
EXIST.
EQUIP.
5' - 0" MIN.
M
IN
ACCESSIONING
1000F
1A1.6
WAREHOUSE
STORAGE
1000A
LOCKED
STORAGE
1000B
CORRIDOR
C010
OFFICE
162A
PB STOR
162B
EQ1EQ1
EQ2EQ2 EQ3EQ3 EQ4EQ4
5.01
5.01
C
LE
A R
8'
A-501
6' - 10" 6' - 0"
1.12
5.05
14.8
P.3 P.4
1A0.4
ALIGN
10.05
A-401
OFFICE
162C
1A0.4 162C
ALIGN
A-501
3' - 6"
A-501
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
KEY PLAN
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/4
/2
:3
:4
P M
A-111
1S T
F L
O O
R P
L A
N
R M
S A
S G
A S
G
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
SCALE: 1/8" = 1'-0"
1ST FLOOR PLAN
NOTES - FLOOR PLANS
1 REFER TO SHEET A-001 FOR GENERAL NOTES
AND SYMBOLS
2 DIMENSIONS MARKED AS "CLEAR" DICTATES THE
CLEAR DIMENSION FROM FINISH TO FINISH
3 ALL DIMENSIONS SHOWN ARE TO FACE OF WALL -
TYPICAL UNLESS NOTED OTHERWISE
4 ALL DOORS TO BE INSTALLED 100mm FROM
HINGE SIDE OF WALL - TYPICAL UNLESS NOTED
OR DIMENSIONED OTHERWISE
5 PAINT ALL INTERIOR WALLS, SURFACE MOUNTED
RACEWAY AND CEILINGS.
6 UNLESS NOTED OTHERWISE, EXISTING STEEL
DOORS AND FRAMES TO REMAIN. SERVICE DOOR
TO ENSURE SMOOTH OPERATION. REFER TO
DOOR SCHEDULE FOR HARDWARE
REQUIREMENTS
7 UNLESS NOTED OTHERWISE, SELECTIVELY
REPLACE DAMAGED CEILING TILES WITH NEW
TILES OR TILES SALVAGED FROM ANOTHER
ROOM WHERE POSSIBLE TO MAINTAIN A
CONSISTENT FINISH SURFACE. REINFORCE
SUSPENDED CEILING GRIDS TO ENSURE
STRUCTURAL INTEGRITY.
8 REHABILITATE EXISTING FINISHES AND PROVIDE
NEW FINISHES PER FINISH SCHEDULE
9 REFER TO ENLARGED PLANS FOR DIMENSIONS
WHERE CALLED FOR
10 REFER TO MECHANICAL DRAWINGS FOR ALL
HEATING VENTILATION AND AIR CONDITIONING
EQUIPMENT LOCATIONS AND REQUIREMENTS
11 REFER TO PLUMBING DRAWINGS FOR ALL
FIXTURE TYPES, DRAINAGE, PLUMBING
VENTILATION, SEWAGE PIPING AND EQUIPMENT
LOCATIONS AND REQUIREMENTS
12 REFER TO ELECTRICAL DRAWINGS FOR ALL
POWER, LIGHTING AND ELECTRICAL EQUIPMENT
LOCATIONS AND REQUIREMENTS
13 CONTRACTOR SHALL COORDINATE ALL TRADES
AND WORK INCLUDING BUT NOT LIMITED TO
MECHANICAL PIPING AND DUCTWORK,
CONDUITS, STRUCTURE, AND SPEAKERS
14 REFER TO SCOPE OF WORK FOR BATHROOM
ACCESSORIES
15 WHERE FIRE RATED PARTITIONS INTERSECT
WITH LESSER RATED PARTITIONS OR NON-RATED
PARTITIONS, THE HIGHER RATED PARTITION IS
TO CONTINUE THROUGH THE INTERSECTION TO
MAINTAIN THE HIGHER RATING
16 FILL VOIDS AROUND WALL PENETRATIONS WITH
FIRE STOPPING TO AVOID REDUCTION OF FIRE
RATING
17 PROVIDE WALL BASE WHERE MISSING. BASE TO
MATCH EXISTING OR NEW FLOOR MATERIAL
18 CONTRACTOR SHALL CLEAN, REPAIR AND PAINT
ALL EXISTING DOORS AND DOOR FRAMES
19 FIRE EXTINGUISHERS SHALL BE PROVIDED AND
LOCATED IN ACCORDANCE WITH NFPA 10. THE
MAXIMUM TRAVEL DISTANCE TO THE NEAREST
FIRE EXTINGUISHER FROM ANY POINT IN THE
BUILDING SHALL NOT EXCEED 22.8 METERS.
EXISTING FIRE EXTINGUISHERS SHALL BE
TESTED AND MAY BE RE-USED IF FULLY
OPERATIONAL.
20 ROOM NUMBERING: ROOM NUMBERING IS TO BE
COORDINATED WITH THE CONTRACTING
OFFICER. SEE AI601 FOR SIGN DETAILS.
21 FOR PARTITION TYPES AND DOOR SCHEDULE,
SEE SHEET A-601
KEYNOTES
1.04 EXISTING RECESSED FIRE EXTINGUISHER TO
REMAIN
1.12 EXISTING CAROUSEL TO REMAIN
5.01 PAINTED GALVANIZED STEEL BOLLARD FILLED
WITH CONCRETE
5.05 FIXED ALUMINUM ACCESS LADDER
6.01 FIRE-RATED (FSC) PLYWOOD BACKERBOARD
7.05 BUILDING VERTICAL EXPANSION JOINT
ASSEMBLY (FIRE RATING TO MATCH PARTITION)
9.04 SAFETY AISLE EPOXY FLOOR MARKING
10.01 RECESSED FIRE EXTINGUISHER CABINET
10.05 POWERED MOBILE STORAGE SHELVING
11.04 RELOCATE EXISTING MOBILE SCISSOR LIFT.
PROVIDE CHARGING STATION - REFER TO
E-SERIES
22.01 EMERGENCY EYE-WASH STATION, SEE
P-SERIES
SCHEDULE - EQUIPMENT (GFGI)
TAG DESCRIPTION QTY
EQ1 SEMI-AUTOMATIC POLY STRAPPING
MACHINE
EQ2 FORK LIFT BATTERY CHARGER 1
EQ3 AUTOMATIC STRETCH WRAP
MACHINE
EQ4 REFRIGERATOR/FREEZER 1
SCALE: 1/8" = 1'-0"
0 4'-0" 8'-0" 16'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a
SC
H
ED
U
LE
H
EA
D
IN
G C
LA
R
IF
IC
AT
IO
N
J U
N E
A S
G a
Aimee.St.Germain Polygonal Line
FIRST FLOOR
0' - 0"
15.5
FOUNDATION CONDITION:
• PREFINISHED METAL BASE FLASHING
• 2" EXTRUDE POLYSTYRENE (XPS)
INSULATION BOARD, EXTEND 2'-0"
HORIZONTALLY
• CAST IN PLACE CONCRETE
FOUNDATION, SEE S-SERIES
FLOOR CONDITION:
• 1/2" COMPRESSIBLE FILLER
• FINISH FLOOR AS SCHEDULED
• VAPOR RETARDER AND COMPACTED
GRANULAR SUB-BASE, SEE S-SERIES
WALL CONDITION:
• INSULATED METAL WALL PANEL (R-14)
TO MATCH EXISTING
• COLD FORMED NON STRUCTURAL
METAL FRAMING WITH R-13 BATT
INSULATION
• 5/8" GYPSUM WALL BOARD, PAINTED
ROOF CONDITION:
• STANDING SEAM METAL ROOF SYSTEM
ON CONTINUOUS MODIFIED BITUMEN
UNDERLAYMENT (THERMAL/AIR
BARRIER)
• 5/8" COVER BOARD
• (2) LAYERS 2.6" MIN.
POLYISOCYANURATE INSULATION
• 1 1/2" STRUCTURAL DECK
• PREFINISHED METAL GUTTER
A-502
A-502
A-502
PLATFORM
13' - 4"
FIRST FLOOR
0' - 0"
P.2
FLOOR CONDITION:
• 1/2" COMPRESSIBLE FILLER
• FINISH FLOOR AS SCHEDULED
• VAPOR RETARDER AND COMPACTED
GRANULAR SUB-BASE, SEE S-SERIES
• SLOPE GRADE AWAY FROM BUILDING
WALL CONDITION:
• INSULATED METAL WALL PANEL (R-14)
TO MATCH EXISTING
• COLD FORMED NON STRUCTURAL
METAL FRAMING WITH R-13 BATT
INSULATION
• 5/8" GYPSUM WALL BOARD, PAINTED
ROOF CONDITION:
• STANDING SEAM METAL ROOF SYSTEM
ON CONTINUOUS MODIFIED BITUMEN
UNDERLAYMENT (THERMAL/AIR
BARRIER)
• 5/8" COVER BOARD
• (2) LAYERS 2.6" MIN.
POLYISOCYANURATE INSULATION
• 1 1/2" STRUCTURAL DECK
• PREFINISHED METAL GUTTER
• CONTINUOUS SNOW GUARD
DOOR CONDITION:
• OVERHEAD DOOR, SEE DOOR SCHEDULE
• GALVANIZED STEEL JAMB COVER
• METAL FLASHING TO MATCH METAL
PANELS
• PROVIDE COLD FORMED METAL FRAMING
AS REQUIRED TO SUPPORT OVERHEAD
DOOR AND MECHANICAL AIR CURTAIN
INSTALLATION REQUIREMENTS
• BOLLARDS BEYOND, SEE S-SERIES
A-611
LOW ROOF LP
17' - 8"
A-502
BOLLARD - REFER TO S-SERES
ROOF CONDITION:
• STANDING SEAM METAL ROOF SYSTEM
• 1 1/2" STRUCTURAL DECK
• PREFINISHED METAL GUTTER
• CONTINUOUS SNOW GUARD
P.3
PLATFORM
13' - 4"
A-501
FIRST FLOOR
0' - 0"
15.8
FLOOR CONDITION:
• 1/2" COMPRESSIBLE FILLER
• FINISH FLOOR AS SCHEDULED
• VAPOR RETARDER AND COMPACTED
GRANULAR SUB-BASE, SEE S-SERIES
LOUVER CONDITION:
• FIXED ALUMINUM LOUVER, SEE M-SERIES
• METAL FLASHING TO MATCH ADJACENT
PANELS
• SEALANT AND BACKER ROD
• RETURN GYPSUM WALL BOARD AT HEAD
AND JAMBS AS APPLICABLE
• PROVIDE PLASTIC LAMINATE WINDOW
STOOL IN EXPOSED AREAS
ROOF CONDITION:
• FULLY ADHERED EPDM ROOF MEMBRANE
• 5/8" COVER BOARD
• (2) LAYERS 2.6" MIN. POLYISOCYANURATE
INSULATION
• 1 1/2" STRUCTURAL DECK
WALL CONDITION:
• INSULATED METAL WALL PANEL (R-14)
TO MATCH EXISTING
• COLD FORMED NON STRUCTURAL
METAL FRAMING WITH R-13 BATT
INSULATION
• 5/8" GYPSUM WALL BOARD, PAINTED
T.O. PARAPET
23' - 6"
HIGH ROOF
21' - 0"
A-502
A-502
A-611
A-502
PIPE GUARDRAIL
PLATFORM
13' - 4" a
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/4
/2
:3
:4
P M
A-311
W A
L L
S E
C T
IO
N
S
R M
S A
S G
A S
G
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
SCALE: 3/4" = 1'-0"
WALL SECTION
SCALE: 3/4" = 1'-0"
WALL SECTION
SCALE: 3/4" = 1'-0"
WALL SECTION
SCALE: 3/4" = 1'-0"
0 1'-0" 2'-0" 4'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a R
O O
F
AS
SE
M
BL
Y
N O
TE
R
EV
IS
ED
J U
N E
A S
G
FEC
FEC
K L M N P R S TK.5
18.7
M.5 N.3L.9
K.8
13.9
18.2
LOGISTICS
AFMES GEN.
STORAGE
OFFICE
162D
CUBICLE
162E
EXIST.
CORRIDOR
EXIST.
STAGING
EXIST. GAS
CYLINDER
EXIST. FIRE
PUMP
EXIST.
LOUNGE
119A
EXIST.
CORRIDOR
EXIST.
ACCESSIONING
EXIST.
RECEIVING
RECEPTION
157A
EXIST.
RECEIVING &
TRANSPORT
157B
EXIST. HAZ.
MAT.
STORAGE
161B
EXIST. HAZ.
MAT.
STORAGE
161A
EXIST. ELEV.
MACH. RM.
1.04
1.04
1.02
1.01
1.01 1.01
1.031.031.03
1.03
AFMES OPS
STORAGE
162A
FORENSICS
TOX.
STORAGE
162B
DNA
STORAGE
162C
EXISTING DIESEL FUEL TANK
EXISTING
GENERATOR
1.08
1.08 1.08
1.08
1.08 1.08
1.09
CLEAR ZONE
EXIST.
EQUIP.
1.11
1.12
1.13
1.01 1.01
1.15
1.14 1.14
+/- 8' - 0" 1.17
1.16
1.07
1.08 PLAN LEGEND DEMO
EXISTING DOOR AND FRAME TO REMAIN
REMOVE EXISTING DOOR, FRAME AND
HARDWARE
EXISTING WALLS TO REMAIN
REMOVE EXISTING WALLS
NOT IN CONTRACT (NIC)
DEMOLITION NOTES
1. ARCHITECTURAL DEMOLITION NOTE SYMBOLS
ARE GENERAL AND MAY NOT INDICATE ALL
EXISTING CONDITIONS. CONTRACTOR SHALL
NOTIFY THE ARCHITECT OF ANY OMISSIONS,
DISCREPANCIES AND/OR CONFLICTS IN
CONTRACT DOCUMENTS BEFORE PROCEEDING
WITH ANY DEMOLITION OR CONSTRUCTION
WORK.
2. BEFORE STARTING WORK, THE CONTRACTOR
SHALL CHECK AND VERIFY DIMENSIONS AND
ELEVATIONS, SURVEY ALL EXISTING
CONDITIONS, PREPARE A LIST OF EXISTING
DAMAGED AREAS VERIFIED BY DATED
PHOTOGRAPHS AND SIGNED BY CONTRACTOR
AND OTHERS CONDUCTING INVESTIGATION.
3. EXISTING WALL, FLOOR AND CEILING MATERIALS
AND/OR FINISHES SCHEDULED TO REMAIN
WITHIN THE AREA OF NEW WORK SHALL BE
PATCHED AND REPAIRED AS REQUIRED TO
RECEIVE NEW SCHEDULED FINISHES OR MATCH
ADJACENT FINISHES.
4. THE OWNER SHALL REMOVE ALL
MISCELLANEOUS WALL MOUNTED EQUIPMENT
AND ACCESSORIES, ETC. PRIOR TO THE START
OF DEMOLITION.
5. EQUIPMENT AND FURNISHINGS REMOVED AND
NOT SCHEDULED FOR RELOCATION SHALL BE
TURNED OVER TO THE OWNER'
REPRESENTATIVE.
6. WHERE NEW FINISHES ARE INDICATED TO BE
PROVIDED BY THE FINISH SCHEDULE,
CONTRACTOR SHALL REMOVE EXISTING
FINISHES INCLUDING LIGHT FIXTURES AND
ELECTRICAL DEVICES NOT SCHEDULED OR
INDICATED TO REMAIN. REFER TO OTHER
DRAWINGS, SCHEDULES AND NOTES FOR
ADDITIONAL INFORMATION. WHERE EXISTING
CERAMIC TILE OCCURS AND IS NOT SCHEDULED
TO REMAIN, THE CONTRACTOR SHALL REMOVE
AND REPAIR OR FILL IN AS REQUIRED TO
ACCOMMODATE INSTALLATION OF SCHEDULED
FINISH.
7. WHERE EXISTING WALL, CEILING OR FLOOR
FINISHES ARE TO REMAIN AND ARE DISTURBED
BY DEMOLITION AND/OR NEW CONSTRUCTION,
THEY SHALL BE REPAIRED AS REQUIRED TO
MATCH ORIGINAL INTEGRITY AND ADJACENT
CONSTRUCTION. REFER TO FINISH SCHEDULE
FOR ADDITIONAL INFORMATION.
8. THE CONTRACTOR SHALL REMOVE, STORE AND
SECURE ALL SALVAGED ITEMS AS INDICATED BY
THE DEMOLITION NOTES OR AS DIRECTED BY
THE OWNER'S REPRESENTATIVE.
9. EXISTING CONSTRUCTION SCHEDULED TO
REMAIN WHICH IS DISTURBED IN ANY WAY BY
THE CONTRACTOR IN ORDER TO ACCOMMODATE
NEW WORK SHALL BE REPAIRED TO ORIGINAL
INTEGRITY AND FINISH TO MATCH EXISTING
FINISHES OR NEW FINISHES AS SCHEDULED.
10. THE CONTRACTOR SHALL COORDINATE WORK
AND ESTABLISH APPROVAL FROM THE OWNER'S
REPRESENTATIVE FOR THE PROCEDURES AND
METHODS OF DEMOLITION REGARDING NOISE
CONTROL AND THE USE OF BUILDING FACILITIES,
INCLUDING TOILETS, HEATING, AIR
CONDITIONING, ELECTRICAL, ETC. THE EXISTING
ELEVATORS MAY NOT BE USED FOR
CONSTRUCTION PURPOSES. THE CONTRACTOR
SHALL PROVIDE THEIR OWN CONSTRUCTION
ELEVATOR AT THE LOCATION DETERMINED BY
THE OWNER'S REPRESENTATIVE. THE
CONTRACTOR SHALL PROVIDE A SEPARATE
TEMPORARY CONSTRUCTION ACCESS.
11. WHERE NEW OPENINGS ARE REQUIRED IN
EXISTING WALLS, THE CONTRACTOR SHALL
PROVIDE NEW LINTELS AS DETAILED.
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
KEY PLAN
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/4
/2
:3
:5
P M
AD111
A R
C H
II
T
E C
T U
R A
L
D E
M O
L
IT
IO
N
P L
A N
S T
F L
O O
R
R M
S A
S G
A S
G
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
SCALE: 1/8" = 1'-0"
DEMOLITION - 1ST FLOOR PLAN
KEYNOTES
1.01 REMOVE EXISTING EXTERIOR WINDOW AND
FRAME ASSEMBLY
1.02 REMOVE EXISTING OVERHEAD ROLLING DOOR
ASSEMBLY. PATCH AND REPAIR WALL AND
FLOOR CONSTRUCTION AS REQUIRED
1.03 REMOVE EXISTING ACOUSTICAL CEILING PANEL
ASSEMBLY, LIGHT FIXTURES AND ASSOCIATED
WIRING, AND MECHANICAL EQUIPMENT AND
DUCTWORK IN THIS AREA. SEE M, E & P-SERIES
DRAWINGS FOR ADDITIONAL INFORMATION
1.04 EXISTING RECESSED FIRE EXTINGUISHER TO
REMAIN
1.07 REMOVE EXISTING CANOPY STRUCTURE AND
FOUNDATIONS. PATCH AND REPAIR ADJACENT
CONSTRUCTION AS REQUIRED
1.08 WHERE PORTION OF EXISTING CONSTRUCTION
TO REMAIN ABUTS CONSTRUCTION TO BE
DEMOLISHED, REMOVE PORTION OF EXISTING
CONSTRUCTION AS REQUIRED. PATH AND
PROVIDE TO COMPONENTS AS NECESSARY TO
MATCH EXISTING ADJACENT CONSTRUCTION
AND FINISHES
1.09 EXISTING SCISSOR LIFT TO BE RELOCATED
1.11 REMOVE EXISTING FIRE EXTINGUISHER
1.12 EXISTING CAROUSEL TO REMAIN
1.13 REFER TO M-SERIES FOR EQUIPMENT
DEMOLITION
1.14 REMOVE EXISTING MOBILE STORAGE SHELVING
AND FLOOR TRACKS. PATCH FLOOR AS
REQUIRED
1.15 REMOVE EXISTING WIRE MESH PARTITION AND
GATE. PATCH FLOOR AS REQUIRED
1.16 REMOVE PORTION OF EXISTING MOBILE
STORAGE SHELVING AND (1) FLOOR TRACK.
PATCH EXISTING CONCRETE FLOOR AS
REQUIRED.
1.17 EXISTING MOBILE STORAGE SHELVING AND (3)
FLOOR TRACKS TO REMAIN.
SCALE: 1/8" = 1'-0"
0 4'-0" 8'-0" 16'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a
KE
YN
O
TE
R
EV
IS
ED
J U
N E
A S
G a
STORM PROFILE
SCALE: 1"=10 H, 1"=2V
-0+05 0+00 0+05 0+10 0+15 0+20 0+25 0+30 0+35 0+40 0+45 0+50 0+55 0+60 0+65 0+70 0+75 0+80 0+85 0+90 0+95 1+00 1+05 1+10 1+15 1+20 1+25 1+30 1+35 1+40 1+45 1+50 1+55 1+60 1+65 1+70 1+75 1+80 1+85 1+90 1+95
-0+05 0+00 0+05 0+10 0+15 0+20 0+25 0+30 0+35 0+40 0+45 0+50 0+55 0+60 0+65 0+70 0+75 0+80 0+85 0+90 0+95 1+00 1+05 1+10 1+15 1+20 1+25 1+30 1+35 1+40 1+45 1+50 1+55 1+60 1+65 1+70 1+75 1+80 1+85 1+90 1+95
CONN
IN
V.
6" O
UT
.17 S
E
N
.49 E
.72
60.38 L.F. 6"
STM. HDPE @ 0.25%
CO-3
IN
V.
6"
IN
.02
N W
IN
V.
6" O
UT
.02 N
E
N
.19 E
.70
RI
M
.68
44.61 L.F. 6"
STM. HDPE @ 0.25%
CO-2
IN
V.
6"
IN
.91
S W
IN
V.
" O
UT
.91 S
E
N
.39 E
.48
RI
M
.76
48.66 L.F. 10"
STM. HDPE @ 0.25%
CO-1
IN
V.
" I
N
.79 N
W
IN
V.
" O
UT
.79
N E
N
.94 E
.96
RI
M
.42
34.59 L.F. 10"
STM. HDPE @ 0.25%
EX.
EX MH
IN
V.
" I
N
.70 S
W
IN
V.
" I N
.70
N E
IN
V.
" O
UT
.70 S
E
N
.01 E
.18
RI
M
.90
SCALE:
CLEANOUT TO GRADE
N.T.S.
SCALE:
ROOF DRAIN COLLECTOR
N.T.S.
SCALE:
NEW 24" PVC DRAIN BASIN
N.T.S.
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L O
T
D
A T
E
P L O
T
S
C A
L E
S U
B M
I T
T E
D
B
Y
D W
N
B
Y
D E
S I G
N E
D
B
Y
C K
D
B
Y
D A
T E
S I Z
E
E
F I L E
N
A M
E
X
S O
L I C
I T
A T
I O
N
N
O
C O
N T
R A
C T
O
C A
T E
G O
R Y
D
E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R
A
I
F
R
B
S
E
A R
M E
D
F
O R
C E
S
M
E D
I C
X A
M I N
S
Y S
T E
M
F
A C
I L
I T
Y
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
S
T
E D
W B
U B
U S
A
R M
Y
E
N G
I N
E E
R
D
I S
T R
I C
T
C O
R P
S
O
F
E
N G
I N
E E
R S
1 2 3 4 5
W B
U D a A
M D
T
J U
A W
V
A
M
J O
P J P
W
A W
V
C D
W G
C-502
SI
TE
A
ND
U
TI
LI
TY
D
ET
AI
LS
AN
D
ST
OR
M
SE
W
ER
P
RO
FI
LE
SCALE:
STORM SEWER PROFILE
AS SHOWN
A
D D
D
D
W
N S
P O
T
E
A N
O U
T
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
CAST IRON SOLID RISER PIPE
AutoCAD SHX Text
CAST IRON STANDARD WYE BRANCH
AutoCAD SHX Text
CAST IRON 45° BEND
AutoCAD SHX Text
CAP END OF WYE BRANCH
AutoCAD SHX Text
FLUSH END CAP CAST GRAY IRON (SEE NOTE 3.)
AutoCAD SHX Text
AutoCAD SHX Text C-502
AutoCAD SHX Text NOTE: 1. PROVIDE 18" DIA. COLLAR IN UNPAVED AND PROVIDE 18" DIA. COLLAR IN UNPAVED AND AGGREGATE AREAS. 2. CLEANOUT WITHIN TRAFFIC AREA: PROVIDE (H-20) CLEANOUT WITHIN TRAFFIC AREA: PROVIDE (H-20) LOAD RATED FRAME AND COVER. 3. SANITARY SEWER CLEANOUT FRAME & COVER SANITARY SEWER CLEANOUT FRAME & COVER SHALL MEET KENT COUNTY STANDARDS.
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
1" ABOVE SURROUNDING GROUND (GRASS)
AutoCAD SHX Text 9"
AutoCAD SHX Text 9"
AutoCAD SHX Text
DOWNSPOUT (REFER TO ARCHITECTURAL PLANS FOR DETAILS)
AutoCAD SHX Text
BUILDING WALL
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
ROOF DRAIN COLLECTOR INSTALLED @ 0.25% MIN. SLOPE (6" DIA. HDPE PIPE)
AutoCAD SHX Text
MATCH EXISTING CAST IRON SHOE (NEENAH R-4925-F OR APPROVED EQUAL)
AutoCAD SHX Text
MANUFACTURER'S STANDARD TRANSITIONAL COUPLING
AutoCAD SHX Text
6" DIA. 45° HDPE ELBOW
AutoCAD SHX Text
6" DIA. HDPE PIPE
AutoCAD SHX Text
ALL FITTINGS AND CONNECTIONS SHALL BE WATER TIGHT
AutoCAD SHX Text C-502
AutoCAD SHX Text
AutoCAD SHX Text
SEE PLAN SHEET FOR COLLECTOR LOCATION
AutoCAD SHX Text
10" DIA. HDPE PIPE
AutoCAD SHX Text
6" DIA. 45° HDPE ELBOW
AutoCAD SHX Text 18" SQUARE CONC. SLAB 6" THICK W/6"X6"-10/10 WWF (CONCRETE SLAB NOT REQUIRED IF CLEANOUT IS LOCATED IN CONCRETE PAVEMENT)
AutoCAD SHX Text C-502
AutoCAD SHX Text
AutoCAD SHX Text NEW 10" ROOF DRAIN COLLECTOR TO NEW PVC DRAIN BASIN INV. EL. = 18.8 (OR AT LEAST 0.1' HIGHER THAN EXISTING 12" OUTLET PIPE)
AutoCAD SHX Text
NEW PVC DRAIN BASIN
AutoCAD SHX Text NOTES: 1. PRIOR TO CONSTRUCTION OF THE NEW 24" DRAIN BASIN, PRIOR TO CONSTRUCTION OF THE NEW 24" DRAIN BASIN, FIELD VERIFY EXISTING PIPE HORIZONTAL LOCATIONS AND INVERT ELEVATIONS AT THE EXISTING DRAIN BASIN. 2. SEE SHEET C-101 FOR HORIZONTAL LOCATION OF NEW SEE SHEET C-101 FOR HORIZONTAL LOCATION OF NEW 10" ROOF DRAIN COLLECTOR PIPE. 3. DRAIN BASIN IS NOT H-25 OR H-20 LOAD RATED.DRAIN BASIN IS NOT H-25 OR H-20 LOAD RATED.
AutoCAD SHX Text
EXISTING 12" ROOF DRAIN OUTLET PIPE (FIELD VERIFY LOCATION)
AutoCAD SHX Text
EXISTING 10" ROOF DRAIN COLLECTOR PIPE (FIELD VERIFY LOCATION)
AutoCAD SHX Text
EXISTING 6" ROOF DRAIN COLLECTOR PIPE (FIELD VERIFY LOCATION)
AutoCAD SHX Text
NEW 10" ROOF DRAIN COLLECTOR PIPE
AutoCAD SHX Text
EXISTING 12" OUTLET PIPE (FIELD VERIFY LOCATION)
AutoCAD SHX Text
EXISTING 6" ROOF DRAIN COLLECTOR PIPE (FIELD VERIFY LOCATION)
AutoCAD SHX Text
SOLID TOP CAST IRON COVER
AutoCAD SHX Text
FLUSH WITH AGGREGATE
AutoCAD SHX Text C-502
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING AND PROPOSED GRADE
AutoCAD SHX Text
STANDARD WYE BRANCH CLEANOUT WITH PLUG
AutoCAD SHX Text a
FEC
F E
FE
FEC
F
E C
FEC
K L M N P R S TK.5
18.7
M.5 N.3L.9
K.8
13.9
18.2
15.5
15.8
M.8 P.2
14.3
N.2M.2 M.4
OFFICE
162A
EXISTING
INDUSTRIAL
SPACE
PB STOR
162B
LOCKED
STORAGE
1000B
CORRIDOR
C010
WAREHOUSE
STORAGE
1000A
ACCESSIONING
1000F
RECEIVING/
RECEPTION
157A
TR
MS1MS1
CORRIDOR
C020
PR4PR4 PR4PR4 PR4PR4
PR8PR8
PR8PR8
PR10PR10
PR8PR8PR8PR8
PR10PR10
PR10PR10
PR10APR10A
PR4PR4
MS2MS2
14.8
P.3 P.4
10' - 6" 10' - 6"
PR10PR10 PR10PR10
PR4PR4
6"
8"
6"
OFFICE
162C
MS3MS3
WR1WR1 WR1WR1 WR1WR1
WR1WR1WR1WR1WR1WR1
WR1WR1 WR1WR1 WR1WR1
WR1WR1
WR1WR1WR1WR1
WR1WR1WR1WR1
WR1WR1
WR1WR1
WR2WR2 WR2WR2
WR1WR1
WR1WR1WR2WR2WR2WR2WR2WR2
3'
3'
WR1WR1WR1WR1WR1WR1
WR1WR1 WR1WR1 WR1WR1
WR1WR1WR1WR1WR1WR1
WR1WR1
WR1WR1 WR1WR1
WR1WR1 WR1WR1
WR1WR1
WR1WR1
WR2WR2
WR2WR2
WR2WR2
WR2WR2
WR2WR2 WR1WR1
WR1WR1
55' - 0"
20' - 0"
1. FURNITURE IS N.I.C. AND SHOWN FOR
REFERENCE ONLY.
2. PALLET RACKS & MOBILE SHELVING SYSTEMS
ARE CFCI.
3. PALLET RACKS ARE TO ACCOMODATE 48" DEEP
PALLETS. FINAL QUANTITY AND SPACING OF
SHELVES MUST BE COORDINATED WITH THE
GOVERNMENT BASED ON PALLET LOAD HEIGHT.
4. WIRE RACKS ARE TO BE PROVIDED WITH FIXED
TOP AND BOTTOM WIRE SHELVES AND (2)
INTERMEDIATE ADJUSTABLE SHELVES.
5. SEE A-111 FOR GFGI SCHEDULED EQUIPMENT.
NOTES - FURNITURE
a
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
KEY PLAN
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/4
/2
:3
:5
P M
IF110
IN
T
E R
IO
R
F U
R N
IT
U
R E
A N
D E
Q U
IP
M
E N
T
S
T F
L O
O R
P L
A N
A L
M L
J B
L J B
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
SCALE: 1/8" = 1'-0"
INTERIOR FURNITURE AND EQUIPMENT - 1ST FLOOR PLAN
SCHEDULE - SHELVING
TAG DESCRIPTION QTY
MS1 MOBILE SHELVING UNIT - 156"H 1
MS2 MOBILE SHELVING UNIT - 80"H 1
MS3 MOBILE SHELVING UNIT
(EXISTING - 80"H)
PR4 PALLET RACK - 4'L x 16'H 5
PR8 PALLET RACK - 8'L x 16'H 4
PR10 PALLET RACK - 10'L x 16'H 5
PR10A PALLET RACK - 10'L x 12'H 1
WR1 ADJUSTABLE WIRE RACK UNIT -
6'L x 6'H x 2'D
WR2 ADJUSTABLE WIRE RACK UNIT -
4'L x 6'H x 2'D
SCALE: 1/8" = 1'-0"
0 4'-0" 8'-0" 16'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a D
IM
ES
N
IO
N S
AD
D
ED
J U
N E
A S
G a a
NOTE: CONTRACTOR TO CONFIRM ALL EXISTING FLOORING CONDITIONS & PROVIDE
APPROPRIATE TRANSITIONS.
T8
SUBSTRATE
EXISTING MCTCARPET
RUBBER ADAPTOR STRIP
T9
SUBSTRATE
METAL STRIP
CARPET
RESINOUS
FLOORING
1st SPECIAL
FORCES
ATTACHMENT
DELTA
NOTE: MOUNTING OPTIONS VARY
PER SIGN TYPE. MOST INTERIOR
SIGNS CAN BE EASILY INSTALLED
USING A COMBINATION OF CLEAR
SILICONE ADHESIVE AND DOUBLE
SIDED FOAM TAPE OR CONCEALED
MECHANICAL FASTENERS.
WHERE THERE IS LESS THAN 18"
CLEAR SPACE ON THE LATCH SIDE
OF A SINGLE DOOR, OR ON THE
RIGHT SIDE OF DOUBLE DOORS,
SIGNS SHALL BE LOCATED ON THE
NEAREST ADJACENT WALL.
WHERE THERE IS A SIDE LIGHT
WINDOW LOCATED ADJACENT TO
THE DOOR, MOUNT THE SIGN TO
THE GLASS AND PROVIDE A
MATCHING BACKER PLATE OF THE
SAME SHAPE AS THE SIGN ON THE
GLASS TO CONCEAL MOUNTING
DEVICE.
3"
M A
X . T
O B
O T
T O
M O
F T
E X
T
EXIT & TYPICAL SIGNS
M
IN
. T O
B O
T T
O M
O F
T E
X T
EXIT
To Be Determined
To Be Determined
To Be Determined
8 1/2"
9"
3" 6"
9"
1-1/2" TACTILE ROOM
NUMBER
WITH BRAILLE HELVETICA
NEUE 55 ROMAN
PRINTABLE INSERT -
3/4" MESSAGE
HELVETICA NEUE 55
ROMAN
INTERIOR APPLICATIONS
EXIT
8 1/2"
9"
3" 3/4" TACTILE TEXT
WITH BRAILLE,
HELVETICA NEUE 55
ROMAN.NOTE: MOUNT SIGN ON DOOR.
STAINLESS STEEL
CORNER GUARD
WP1 - WALL PROTECTION
WP1 - WALL PROTECTION
TOP TRIM
WALL BASE AS SCHEDULED
OUTSIDE CORNER
CEILING
T O
M A
T C
H E
X
IS
T
IN
G
V
IF
W A
LL
P
R O
T E
C T
IO
N
D
IM
E N
S
IO
N S
EPOXY WALL BASE TO WALL - TYPICAL
STAINLESS
TRANSITION STRIP
WALL FINISH AS
SCHEDULED
RESINOUS
FLOORING
W A
L L
FLOOR
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/4
/2
:3
:5
P M
IN001
IN
T
E R
IO
R
F
IN
IS
H
S C
H E
D U
L E
S D
E T
A
IL
S A
N D
S
IG
N A
G E
A L
M L
J B
L J B
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
NOTES - FINISH
1 SEE TECHNICAL SPECIFICATIONS & INTERIOR
FINISH DRAWINGS FOR INTERIOR FINISH
INFORMATION.
2 INTERIOR FLOOR PLAN SHOWN IN THE 'IN'
SERIES ARE FOR FINISH LOCATIONS ONLY.
REFER TO ARCHITECTURAL DRAWINGS FOR
DIMENSIONS AND CONSTRUCTION
INFORMATION.
3 MATERIAL FLOOR AND WALL TRANSITIONS ARE
TO BE COORDINATED WITH SELECTED
PRODUCTS AND INSTALL PER MANUFACTURER'S
RECOMMENDATIONS. PROVIDE BARRIER FREE
TRANSITIONS AT ALL FLOOR CHANGES. SEE
TRANSITION DETAILS, IN001, FOR MORE
INFORMATION.
4 METAL GRILLS, DIFFUSERS, PANEL BOXES AND
REGISTERS LOCATED WITHIN OCCUPIED AREAS
ARE PAINTED TO MATCH THE ADJACENT WALL
FINISH AS NOTED ON THE FINISH SCHEDULE.
5 SEE IN001 FOR INTERIOR MATERIAL & COLOR
SCHEDULE, INTERIOR ROOM FINISH SCHEDULE,
AND INTERIOR DETAILS.
6 REFER TO INTERIOR FINISH DRAWINGS FOR
ACCENT WALL LOCATIONS / EXTENTS.
7 PROVIDE FLEXIBLE SEALANT AT WALL AND
FLOOR JOINT WHERE THERE IS NO WALL BASE
REQUIRED.
8 CONTROL JOINTS WILL MATCH THE COLOR OF
THE ADJACENT FLOORING MATERIAL.
9 REFER TO ARCHITECTURAL REFLECTED CEILING
PLANS, SERIES AR100, FOR CEILING HEIGHTS.
10 EXPOSED CEILINGS ARE PAINTED ENTIRELY;
INCLUDING EXPOSED STRUCTURE, DECK,
DUCTWORK, CONDUIT, PIPING, ETC. GYPSUM
BOARD CEILINGS AND SOFFITS ARE PAINTED AS
SCHEDULED.
SCALE: NTS
INTERIOR TRANSITION STRIPS
SCHEDULE - FINISH - MATERIAL & COLOR
FINISH MATERIAL DESCRIPTION MANUFACTURER STYLE / TYPE COLOR SIZE REMARKS
ACT1 ACOUSTIC CEILING TILE USG HALCYON CLIMAPLUS 98225 WHITE 24" x 24" x 1"; 9/16" GRID WHITE
CG1 CORNER GUARD KOROGUARD STAINLESS STEEL GS30 #4 SATIN FINISH 3" WINGS ALL OUTSIDE CORNERS AT WP1
CG2 CORNER GUARD - END CAP KOROGUARD STAINLESS STEEL #4 SATIN FINISH 'U' ENDCAP
CPT1 CARPET TILE INTERFACE EQUATOR II RAIN 9871 50CM X 50CM BRICK INSTALL
EF1 STANDARD RESINOUS FLOORING STONHARD STONCLAD HT SILVER GRAY SEE SPECIFICATIONS 4"H INTEGRAL COVE BASE WITH METAL
TOP CAP
ETR EXISTING FINISH TO REMAIN N/A N/A N/A N/A N/A
N/A SIGNAGE INPRO VARIES DARK GREY ON BEIGE 0117 MATCH EXISTING SIGNAGE
N/A WOOD DOORS BIRCH MATCH EXISTING
P1 PAINT - FIELD WALL SHERWIN WILLIAMS VARIES, SEE SPECIFICATIONS SW6141 SOFTER TAN
P2 PAINT - FIELD CEILING SHERWIN WILLIAMS VARIES, SEE SPECIFICATIONS SW7007 CEILING BRIGHT WHITE
RB1 RESILIENT BASE JOHNSONITE TRADITIONAL WETLANDS 150 4"H TRADITIONAL COVED AT HARD/RESILIENT SURFACES, STRAIGHT AT CARPET
SDT1 STATIC-CONTROL RESILIENT FLOORING FORBO COLOREX SD SAHARA 24.25" X 24.25" X 0.80" IT ROOM
WP1 WALL PROTECTION ACROVYN .060N HIGH IMPACT WALL
COVERING
858 PUMICE 4'-0" ABOVE FINISHED FLOOR PROVIDE ALL REQUIRED TRIM PIECES FOR
FINISHED SYSTEM
INTERIOR ROOM FINISH SCHEDULE
NUMBER NAME FLOOR WALL BASE WALL CEILING REMARKS
157A RECEIVING/ RECEPTION EF1 - P1 P2
162 EXISTING INDUSTRIAL SPACE EF1 - P1/WP1 P2 CG1; WP1 & CG1 AT COLUMNS
162A OFFICE CPT1 RB1 P1 ACT1 CG1
162B PB STOR EF1 - P1 P2 CG1
162C OFFICE CPT1 RB1 P1 ACT1
1000A WAREHOUSE STORAGE EF1 - P1/WP1 P2 CG1
1000B LOCKED STORAGE EF1 - P1 P2
1000F ACCESSIONING EF1 RB1 P1 ETR
1002 TR SDT1 RB1 P1 P2
C010 CORRIDOR EF1 - P1/WP1 P2 CG1
C020 CORRIDOR EF1 - P1/WP1 P2 CG1
SCALE: 1/2" = 1'-0"
SIGN INSTALLATION DETAILS
SCALE: NTS
ROOM ID WITH INSERT - TYPE A
SCALE: NTS
EXIT - TYPE B
SCALE: NTS
EXISTING SIGNAGE PHOTO
NOTES - SIGNAGE
1 REFER TO ABAAS REQUIREMENTS & IN001
REGARDING SIGN MOUNTING HEIGHT, USE OF
PICTOGRAMS, FINISH & CONTRAST.
2 SIGN FINISHES, STYLES & COLORS ARE TO
MATCH EXISTING INTERIOR BUILDING SIGNAGE.
3 SIGNS ARE MOUNTED 3" FROM LATCH SIDE OF
DOOR FRAME OR OPENING AND MOUNTED
PERPENDICULAR TO THE LATCH SIDE OR DOOR
OPENING WHERE WALL SPACE DOES NOT
ALLOW. CENTERLINE OF SIGNS TO BE MOUNTED
AT 60" AFF. SEE IN001 FOR MOUNTING
INFORMATION.
4 SIGNS MOUNTED ON GLASS TO HAVE MATCHING
BACKER PLATE OF THE SAME SHAPE AS THE
SIGN AND SHALL MATCH THE COLOR OF THE
SIGN.
5 SIGNS MOUNTED ON THE EXTERIOR MUST BE
CONSTRUCTED OF DURABLE
FACTORY-FINISHED BAKED ENAMEL WITH
REFLECTIVE SHEETING. FASTENERS SHALL BE
CONCEALED AND RUST PROOF.
6 PROVIDE REQUIRED MOUNTINGS / HANGING
MECHANISMS FOR SPECIFIED SIGNS PER
MANUFACTURERS RECOMMENDATIONS FOR
LOAD.
7 SURFACE APPLIED VINYL LETTERS OR
GRAPHICS THAT CAN BE RUBBED OFF OR
DAMAGED AND EXPOSED PAPER INSERTS ARE
PROHIBITED.
8 CONTRACTOR TO PROVIDE SOFTWARE,
ADDITIONAL MESSAGE SLOTS FOR FUTURE
INSERTS & ATTIC STOCK FOR SIGNS;
COORDINATE WITH OWNER.
9 UNLESS NOTED OTHERWISE, TEXT ON SIGNS
ARE IN ALL CAPITAL LETTERS.
10 CONTRACTOR TO CONFIRM THAT THE
GOVERNMENT HAS REVIEWED AND APPROVED
ALL SIGNAGE MESSAGE VERBIAGE, FINAL ROOM
NUMBERS AND FINAL ROOM NAMES; PRIOR TO
ORDERING SIGNAGE PACKAGE.
11 CONTRACTOR TO COORDINATE NUMERICAL
REPRESENTATIONS AND SIGN VERBIAGE WITH
OWNER FOR APPROVAL PRIOR TO FABRICATION.
12 EXTERIOR SIGNS MUST CONFORM TO
MANUFACTURER RECOMMENDATIONS FOR
APPLICATION AND ARE TO COMPLY WITH BASE
STANDARDS.
13 EXTERIOR DOORS SHALL RECEIVE ROOM
NUMBER PLAQUE ON EXTERIOR HEADER OF
DOOR FRAME; UNLESS DIRECTED OTHERWISE
BY GOVERNMENT / OWNER.
14 CONTRACTOR TO PROVIDE FLAG SIGNS
INDICATING DEFIBRILLATORS, FIRE
EXTINGUISHERS, FIRST AID KITS AND EYEWASH
STATION LOCATIONS. SIGNAGE TO BE PROVIDED
AT EACH LOCATION OF CORRESPONDING
SAFETY EQUIPMENT.
SCALE: NTS
DETAIL - EXISTING WALL
PROTECTION/CORNER GUARD
SCALE: 1/2" = 1'-0"
DETAIL - WALL PROTECTION /
CORNER GUARD CONDITION
SCHEDULE - INTERIOR SIGNAGE
SIGN #
SIGN
TYPE
ROOM
NUMBER ROOM NAME SIGN MESSAGE / "DESCRIPTION" COMMENTS
1 A 162A OFFICE "162A / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
2 A 162 EXISTING INDUSTRIAL SPACE "162 / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
3 A 162B PB STOR "162B / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
4 A 163 GAS CYLINDER "163 / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
5 B 162 EXISTING INDUSTRIAL SPACE EXIT MOUNTED ON DOOR
6 A 1000B LOCKED STORAGE "1000B / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
7 A 1000A WAREHOUSE STORAGE "1000A / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
8 B C010 CORRIDOR EXIT MOUNTED ON DOOR
9 A 1002 TR "1002 / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
10 B 1000A WAREHOUSE STORAGE EXIT MOUNTED ON DOOR
11 A 1000F ACCESSIONING "1000F / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
12 A 157A RECEIVING/ RECEPTION "157A / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
13 A 162C OFFICE "162C / PRINTABLE INSERT (ROOM / OCCUPANTS NAME AND TITLE (DETERMINED BY OWNER)"
SCALE: 1/2" = 1'-0"
0 1'-0" 2'-0" 4'-0"
SCALE: NTS
DETAIL - INTERIOR WALL TRANSITION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a
SP
EL
LI
N G
C O
R R
EC
TE
D
J U
N E
A S
G a
SUPPLY AIR FLEX DUCT
(LOW PRESSURE) MAX.
LENGTH 5'-0"
REHEAT COIL WHERE
SPECIFIED SEE PIPING DETAIL
FOR SPECIALTIES
DISCHARGE ATTENUATOR
WHERE SPECIFIED
FLEX INLET DUCT
(MEDIUM PRESSURE)
MAX. LENGTH 2'-0"
PRESSURE TAPS FOR FIELD
AIR FLOW SETTINGS
OUTLET VOLUME
DAMPER
PROVIDE RIGID INSULATED ROUND
DUCT FOR RUNOUTS OVER 8'-0"
FROM MAIN(TYPICAL ALSO FOR
DISCHARGE DUCT)
AIR TERMINAL BOX TYPICAL ANY
TYPE (SEE SCHEDULES FOR
CAPACITIES)
EXTERNALLY WRAP INSULATION
OVER SUPPLY AIR INLET DUCT.
PROVIDE CEILING ACCESS TO
EACH TERMINAL BOX IN
NON-ACCESSIBLE CEILINGS.
PROVIDE A MIN. OF 18" (OR 2X INLET DIA. FOR
INLETS >10" D.) OF STRAIGHT, HARD DUCT
BEFORE INLET. POSITION ANY TRANSITIONS
BEFORE INLET DUCT.
VOLUME CONTROLLER
'NYLON' TIES
HANGER STRAP
CEILINGDAMPER OPERATOR
AIR
FLOW
DISCHARGE PLENUM (SEE PLAN
FOR ARRANGEMENTS)
OR MAY BE DIRECTLY DUCTED
MV
HWR
HWS
COIL
MANUAL AIR VENT
PRESSURE GAUGE
THERMOMETER IN WELL (TYP)
2-WAY ATC VALVE
MANUAL CALIBRATED
BALANCING VALVE (TYP)
ISOLATION VALVE (TYP)
PRESSURE/TEMPERATURE PORT (TYP)
STRAINER (TYP)
TYPICAL UNION FOR SMALLER PIPE
SIZES, FLANGES FOR LARGER SIZES
3/4" DRAIN VALVE WITH HOSE
CONNECTION, CAP, & CHAIN (TYP)
RISER RUNOUT
BRANCH PIPING TAKE-OFF
SUPPLY AND RETURN MAINS
ISOLATION VALVE (TYP)
2" AND BELOW: BALL VALVE
2-1/2" AND ABOVE: BUTTERFLY
VALVE
BRANCH PIPING: PIPING
FROM MAIN CONNECTING
TWO OR MORE DEVICES
FLOOR LEVEL
SUPPLY AND
RETURN MAINS
ISOLATION VALVE (TYP)
2" AND BELOW: BALL VALVE
2-1/2" AND ABOVE: BUTTERFLY VALVE
DRAIN VALVE (BALL VALVE)W/
HOSE BIBB ADAPTOR (TYP)
BALANCING VALVE
NON COMPRESSIVE EXTRUDED
POLYSTYRENE INSULATION.
CONTRACTOR TO COORDINATE
COMPRESSIVE STRENGTH WITH
EQUIPMENT WEIGHT.
SECURE AT BASE AND
CAP 12" O.C.
PRE-FAB SUPPORT RAIL
ROOFING UP UNDER
METAL CAP
12" MIN.
ROOF INSULATION
ROOFING
STEEL ROOF DECK
NOTE:
1. WOOD NAILERS, ROOFING AND ANY ADDITIONAL
STRUCTURAL SUPPORT BY GENERAL CONTRACTOR.
.3-1/2"
1-1/2"
METAL CAP
DRAIN PAN
CLEAN OUT
PLUG
PITCH DOWN
TOWARDS DRAIN DRAIN LINE SIZE FULL SIZE
OF DRAIN PAN OUTLET
"X"
"Y"
DRAIN PLUG
POSITIVE PRESSURE APPLICATION
(BLOW THROUGH UNIT)
"X" = TOTAL FAN SP + 2"
"Y" = 2" MINIMUM
NEGATIVE PRESSURE APPLICATION
(DRAW THROUGH UNIT)
"X" = 1/2 "Y"
"Y" = TOTAL FAN SP + 2"
BIRDSCREEN PRE-FAB CURB
EXHAUST DUCT
MOTORIZED DAMPER
ROOF
ACCESS DOOR
SEE ARCH. DWG. FOR
FLASHING DETAILS
NOTE:
FAN CONTAINS VIBRATION ISOLATORS FOR SUPPORTING
THE DRIVE ASSEBLY AND FAN WHEEL.
CONDUIT
WIRING BY OTHERS
EQUIPMENT BASE
OR LEG
NEOPRENE PAD
ISOLATION MOUNTS
STRUCTURAL PLATFORM
ANCHOR TO STRUCTURAL PLATFORM
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/5
/2
:2
:3
P M
M-502
M E
C H
A N
IC
A
L
D E
T A
IL
S
D W
H A
J K
B D
M
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
SCALE: NTS2
AIR TERMINAL BOX INSTALLATION
SCALE: NTS4
COIL PIPING W/2-WAY VALVES DETAIL
SCALE: NTS3
TYPICAL PIPING TAKE-OFF DETAILS
SCALE: NTS6
SUPPORT RAIL
SCALE: NTS7
CONDENSATE TRAP/DRAIN DETAIL
SCALE: NTS1
ROOF MOUNTED CENTRIFUGAL EXHAUST FAN DETAIL
SCALE: NTS5
AHU MOUNTING DETAIL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a A
M D
T
J
U N
E
B D
M a
Brandon.Maseth Image
K L M
M.8
N
P.2
P R S T
15.5
1 2
3 4
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
8 2
14.3
15.8
N.2M.4M.2
(TYP.)
(TYP.)
(TYP.)
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
KEY PLAN
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/5
/2
:2
:3
P M
MD111
M E
C H
A N
IC
A
L
D E
M O
L
IT
IO
N
P L
A N
S T
F L
O O
R
D W
H A
J K
B D
M
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
KEYNOTES
1 REMOVE AND RELOCATE EXISTING SERVER
ROOM AIR COOLED CONDENSER. MOVE AND
RE-ENABLE ONE UNIT AT A TIME TO MAINTAIN
COOLING. COORDINATE AND SCHEDULE
OUTAGES WITH GOVERNMENT.
2 PROVIDE TEMPORARY AIR CONDITIONING FOR
TIMES WHEN AIR CONDITIONING IS OUT OF
SERVICE.
3 REMOVE AND RELOCATE EXISTING
TELECOMMUNICATIONS AIR COOLED
CONDENSING UNIT. COORDINATE AND
SCHEDULE OUTAGES WITH GOVERNMENT.
4 REMOVE EXISTING REFRIGERANT PIPING.
RECLAIM AND RECYCLE REFRIGERANT. CAP
OPEN ENDS OF PIPING DURING CONSTRUCTION.
PROVIDE RECYCLYING DOCUMENTATION TO
GOVERNMENT.
6 REMOVE EXISTING DUCTWORK IN ITS ENTIRETY
INCLUDING BUT NOT LIMITED TO HANGERS,
ANCILLARY SUPPORTS, ANCHORS, INSULATION.
PROVIDE AND SEAL SHEETMETAL CAPS ON
OPEN ENDS OF DUCTWORK DURING
CONSTRUCTION.
7 REMOVE EXISTING VAV BOX IN ITS ENTIRETY
INCLUDING BUT NOT LIMITED TO HANGERS,
ANCILLARY SUPPORTS, ANCHORS, INSULATION,
ASSOCIATED THERMOSTAT, WIRING, CONDUIT
AND CONTROLS.
8 COORDINATE AIR DISTRIBUTION OUTAGES WITH
GOVERNMENT.
9 COORDINATE WORK IN THIS AREA WITH
GOVERNMENT CONTRACT REPRESENTATIVE.
10 CAP OPEN END OF DUCT WITH LIKE THICKNESS
SHEET METAL. SEAL AIR TIGHT. TYPICAL OF 2.
11 TEMPORARY CONDITIONING SHALL CONSIST OF
8 TONS R.
12 TEMPORARY CONDITIONING SHALL CONSIST OF
12 TONS R FOR EACH UNIT.
SCALE: 1/8" = 1'-0"
MECHANICAL DEMOLITION - 1ST FLOOR PLAN
SCALE:
4' - 0" 8' - 0" 16' - 0"
1/8" = 1' - 0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a A
M D
T
J
U N
E
B D
M a a
Brandon.Maseth Image
M.2
M.2
15.8
15.8
P.2
P.2
M
M
14.314.3
15.515.5
1'
2' - 8" 4' - 5" 4' - 10" 17' - 6" 10' - 0" 25' - 3"
M.4
M.4
M.8
M.8
N.2
N.2
13.9 13.9
L.9
L.9
M.5 N P R
9'
1'
1'
2' - 8" 4' - 5" 4' - 10" 6' - 9" 10' - 9" 3' - 3" 6' - 9" 23' - 3"
2' - 0"
28' - 0"
W F
WF20
W F
(-1'-10")
1'
-1 0"
(-1'-10")
1'
-1 0"
(-1'-10")WF20
F5.5 F5.0
F8.0
F5.0F5.5F5.5
F5.0 F5.0
WF20
W F
1' -1
0"
BOLLARD (TYP)
RE: 11/S-501
S-10
RE: NOTE 14
RE: NOTE 14
S-311
S-311
S-311
S-311
S-311
FACE OF
EXISTING BLDG
FACE OF
EXISTING BLDG
NEWEXISTING
E X
IS
T
IN
G
N E
W
S-311
1' - 5"
FACE OF
EXISTING BUILDING
S-311
C2
C2
C2
S-311
F5.5
C2
RE: NOTE 15
1'
0"
C1 1' - 10"
C2
1'
1'
C
O R
B E
LS
FACE OF
EXISTING BUILDING
S-311
C3C3
C2
1'
0"
1' - 10"
C J, T Y
P
CJ, TYP
16' - 0"
3' - 0"
F6.0
C4
C4
F6.0
C4
F4.0
RE: NOTE 13
C4
FD
2' - 6"
GB1
GB1
P.3 P.4
14.8
S-311
CLEAR ZONE, R
E: A
RCH
RE: NOTE 10
(TYP)
6A
S-311
RE: NOTE 10
(TYP)
3' - 0" 1'-6" MIN
3' - 0" 1'-6" MIN
S-311
STEP FTG
STEP FTG
RE: NOTE 18
WF20 (-2' - 10")
WF20 (-1' - 10")
FOUNDATION PLAN NOTES:
1. RE: DRAWING S-001 FOR GENERAL NOTES AND
DESIGN CRITERIA.
2. COORDINATE DIMENSIONS, WALL OPENINGS,
ELEVATIONS, SECTIONS, AND DETAILS WITH
ARCHITECTURAL DRAWINGS.
3. THE CONTRACTOR IS TO COORDINATE
DIMENSIONS, WALL OPENINGS, ELEVATIONS,
SECTIONS, DETAILS, AND NEW EQUIPMENT
WITH ARCHITECTURAL DRAWINGS AND FIELD
CONDITIONS. DO NOT SCALE DRAWINGS.
VERIFY ALL DIMENSIONS WITH EXISTING
CONDITIONS AND REPORT ALL DISCREPANCIES
TO ARCHITECT.
4. TOP OF SLAB ELEVATION = RE: CIVIL. THIS IS
THE DATUM ELEVATION = 0’-0”. ALL
ELEVATIONS ARE REFERENCED FROM THIS
ELEVATION.
5. TOP OF CONCRETE FOOTING ELEVATIONS =
-1'-6" (TYP UNO).
6. TOP OF GRADE BEAM
ELEVATIONS = -1'-6" (TYP, UNO).
7. S-# DENOTES A REINFORCED CONCRETE SLAB-
ON-GRADE PLACED OVER A VAPOR RETARDER
AND 4" DRAINAGE BASE COURSE MATERIAL.
a. S-10 = 10” THICK CONCRETE REINFORCED
WITH #4 @ 10" O.C. EW.
b. VAPOR BARRIER UNDER SLAB ON GRADE TO
BE 10 MIL MINIMUM THICKNESS AND MUST
BE SEALED AT FOUNDATION PERIMETER
AND AT ALL PENETRATIONS.
8. CJ DENOTES SLAB CONTROL JOINT. SPACE
SLAB CONTROL JOINTS AT COLUMNS, AND
EQUALLY BETWEEN COLUMNS, AS SHOWN AT
A SPACING NOT EXCEEDING 18’-0” WITH A
LENGTH TO WIDTH RATIO NO GREATER THAN
1.5:1.0 RE: 1/S-501.
9. PROVIDE SLAB ISOLATION JOINT AT ALL
COLUMNS. RE: 3/S-501.
10. PROVIDE ADDITIONAL SLAB REINFORCEMENT
AT ALL RE-ENTRANT CORNERS AND
DISCONTINUOUS SLAB JOINTS. RE: 4/S-501.
11. RE: DRAWING S-501 FOR TYPICAL FOUNDATION
AND SLAB DETAILS.
12. FD INDICATES APPROXIMATE LOCATION OF
FLOOR DRAIN. COORDINATE MECHANICAL
PENETRATIONS W/ M/E/P DRAWINGS.
13. FOUNDATIONS AND SLAB ON GRADES ARE TO
BE PLACED ON SOIL IMPROVED AGGREGATE
PIERS. RE: NOTE F-2 ON S-001. PROVIDE 5'-0"
CLEARANCE FROM CENTERLINE OF
AGGREGATE PIER TO FACE OF EXISTING
BUILDING VENEER DUE TO VIBRATION IMPACTS
TO EXISTING BUILDING. AGGREGATE PIERS
MAY BE CLOSER TO EXISTING BUILDING
PROVIDED THAT VIBRATION LIMITS NOTED IN
THE SPECIFICATIONS ARE NOT EXCEEDED.
FINAL DESIGN AND AGGREGATE PIER
LOCATIONS IS BY SPECIALTY CONTRACTOR.
14. EXISTING CONCRETE PADS TO REMAIN.
FIELD VERIFY LOCATIONS.
15. HIGH DENSITY STORAGE. RE: ARCH FOR
LOCATION. SPACE SURFACE MOUNTED RAILS
AS REQUIRED TO NOT EXCEED 1375 PLF RAIL
LINE LOAD. GC TO COORDINATE SURFACE
MOUNTED RAIL LOCATIONS WITH HIGH DENSITY
STORAGE MFR.
16. FD INDICATES APPROXIMATE LOCATION OF
FLOOR DRAIN. COORDINATE MECHANICAL
PENETRATIONS WITH M/E/P DRAWINGS.
17. GB# DENOTES GRADE BEAM.
RE: SCHEDULE ON S-502.
18. STEP FOOTING FOR SANITARY LINE.
RE: PLUMBING FOR LOCATION. RE: 7/S-501 FOR
STEPPED FOOTING DETAIL.
FOOTING LEGEND
FXX (X'-X")
COLUMN FTG MARK
(RE: SCHED ON S-601)
T/FTG EL
(IF DIFFERENT
FROM TYP)
PIER = FTGCL
P
IE
R
F T
G C L
PX (X'-X")
PIER MARK
(RE: SCHED ON S-601)
COL MARK
(RE:SCHEDULE
ON S-601)
T/PIER EL
(IF DIFFERENT
FROM TYP)
PNN
1 2 3 4 5
A
B
C
D
PLATE REFERENCE
NUMBER
SHEET OF
P L
O T
D A
T E
P
L O
T S
C A
L E
S U
B M
IT
T
E D
B Y
D W
N B
Y
D E
S
IG
N E
D B
Y : C
K D
B Y
D A
T E
S
IZ
E
E
F
IL
E N
A M
E
"X
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
C A
T E
G O
R Y
C O
D E
US ARMY CORPS
OF ENGINEERS
PHILADELPHIA
DISTRICT
D O
V E
R A
IR
F
O R
C E
B A
S E
A R
M E
D F
O R
C E
S M
E D
IC
A
L E
X A
M
IN
E R
S Y
S T
E M
F A
C
IL
IT
Y
A S
N O
T E
D
-0
-0
W
B
U -2
-B
-0
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
C O
R P
S O
F E
N G
IN
E
E R
S
KEY PLAN
1 2 3 4 5
-D o v e r
A F
M E
S W a re h o u s e
W
B
U -1
-D
-0
/5
/2
:5
:3
P M
SB111
F O
U N
D A
T
IO
N P
L A
N S
L A
B P
L A
N
N L
B D
Y H
D R
B
IS
S
U E
D F
O R
C O
N S
T R
U C
T
IO
N
-0
-1
1/8" = 1'-0"
FOUNDATION PLAN
SCALE: 1/8" = 1'-0"
0 4'-0" 8'-0" 16'-0"
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R a C
L A
R
IF
IE
D
H
IG
H D
E N
S
IT
Y S
T O
R A
G E
R A
IL
S
J
U N
E
D R
B a
02 JUNE 2020
| A111 |
| A311 |
| AD111 |
| C502 |
| Sheets and Views |
| C-502 |
| IF110 |
| 172884-Dover AFMES Warehouse - IF110 - INTERIOR FURNITURE AND EQUIPMENT - 1ST FLOOR PLAN |
| IN001 |
| M502 |
| 172884 - Sheet - M-502 - MECHANICAL - DETAILS |
| MD111 |
| SB111 |
| Sheets |
| SB111 - FOUNDATION PLAN / SLAB PLAN |
File details come from the government source that posted it. Updated .