Am0001 Drawing G-103.pdf
PDF 401 KB Posted
- Solicitation number
- W9128F21R0004
About this file
This document contains a drawing and site plan for a federal construction contract opportunity with the U.S. Army Corps of Engineers. The drawing depicts the layout for temporary containment areas that will be established to support the installation of four GSU transformers at the Fort Randall Dam and Reservoir in South Dakota. Specific requirements include preparing ground surfaces and excavating areas for the temporary containment berms, installing temporary fencing and power from the switchyard, and ensuring the containment areas can accommodate all work areas and provide safe touch voltage. The related federal contract opportunity is solicitation number W9128F21R0004 for GSU transformer installation services at Fort Randall Dam, with an estimated award date in fiscal year 2021. The contracting agency is the Department of the Army Corps of Engineers Engineering District Omaha.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA
NEW CONTAINMENT
AREA
NEW CONTAINMENT
CABLE TUNNEL
EXISTING
FENCE
EXISTING
73'-0"
TYP
SEE NOTE 3
SEE NOTE 3
SEE NOTE 4
CONTAINMENT AREA
NEW TEMPORARY
SEE NOTE 4
CONTAINMENT AREA
NEW TEMPORARY
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
AUTO-TRANSFORMER
BANK 'E'
TRANSFORMER
UNTANKING
HOUSE
AREA
NEW CONTAINMENT
AREA
NEW CONTAINMENT
SWITCHYARD ACCESS GATE
UNTANKING HOUSE
TRANSFORMER
TUNNEL
EXISTING CABLE
SEE NOTE 3
SEE NOTE 3
SEE NOTE 4
CONTAINMENT AREA
NEW TEMPORARY
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
CONTAINMENT AREA.
CONTAINMENT TO REACH ALL AREAS OF THE TEMPORARY
AREA. PROVIDE ADEQUATE SLACK AT THE TEMPORARY
GROUND MAT TO THE EDGE OF THE TEMPORARY CONTAINMENT
5. PROVIDE A #4/0 GROUND CONDUCTOR FROM THE SWITCHYARD
PLACEMENT PER SECTION 31 00 00.00 26
PREPARE GROUND SURFACE FOR TEMPORARY CONTAINMENT
TEMPORARY CONTAINMENT PLACEMENT. EXCAVATE AND
FOR A MORE DETAILED VIEW OF THE NEW CONTAINMENT AND
A 54' BY 14' TEMPORARY OIL CONTAINMENT BERM. SEE S-101
4. THE TEMPORARY CONTAINMENT AREA MUST ACCOMMODATE
OR BE OF NON-CONDUCTIVE MATERIAL.
GROUNDED TO PROVIDE SAFE TOUCH VOLTAGE PER IEEE 80
TRANSFORMER STORAGE AREA. TEMPORARY FENCE MUST BE
INSTALLATION. PROVIDE TEMPORARY FENCE AROUND THE
CONDITION AFTER COMPLETION OF THE TRANSFORMER
REINSTALLED AND GROUNDED BACK TO ITS ORIGINAL
AND TRANSFORMER INSTALLATION. FENCE MUST BE
TO ACCOMMODATE TEMPORARY TRANSFORMER STORAGE
3. REMOVE EXISTING FENCE EAST OF EACH TRANSFORMER
TEMPORARY CONTAINMENT AREA.
TEMPORARY CONTAINMENT TO REACH ALL AREAS OF THE
SPECIFICATIONS. PROVIDE ADEQUATE SLACK AT THE
CONTAINMENT AREA IN ACCORDANCE TO NFPA 70 AND THE
POWER LOCATIONS IDENTIFIED TO THE EDGE OF TEMPORARY
2. PROVIDE AND ROUTE TEMPORARY POWER FROM THE 120VAC
PROVIDED BY THE TRANSFORMER SUPPLY CONTRACTOR.
PER SPECIFICATIONS. OIL CONTAINMENT WILL BE
1. TEMPORARY CONTAINMENT AREA MUST BE PREPARED
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10 11 12 13
H
J
SHEET ID
F
IL
E N
A M
E
D R
A W
IN
G N
O
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
G
S U T
R A
N S
F O
R M
E R I
N S
T A
L L
S W
IT
C H
Y A
R D
M
IS
S O
U R I
R
IV
E R
F O
R T R
A N
D A
L L D
A M A
N D R
S V
R
W F
R
F R
G .0
G -1
.d g n
F R
G -1 .0
-0 /5
E
V A
U G
H N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
G-103
S T
E V
E N R
M
IL
E S P .E
A N
S I F
/1
/2
PLAN
NORTH
M T
H O
M P
S O
N
T
M C
G
IL
V R
E Y P .E
L O
C A
T
IO
N S
P
L A
N
T E
M P
O R
A R
Y C
O N
T A
IN
M E
N T A
R E
A
PLAN
NORTH
SCALE: 1" = 30'- 0"
SCALE: 1" = 30'- 0"
NOTES:
SITE PLAN
TRANSFORMER A AND B
SITE PLAN
TRANSFORMER C AND D
TRANSFORMER A
TRANSFORMER B
TRANSFORMER C
TRANSFORMER D
A M
G
E N
E R
A L R
E V
IS
IO
N
-1
-2
AREA
NEW CONTAINMENT
AREA
NEW CONTAINMENT
CABLE TUNNEL
EXISTING
FENCE
EXISTING
73'-0"
TYP
SEE NOTE 3
SEE NOTE 3
SEE NOTE 4
CONTAINMENT AREA
NEW TEMPORARY
SEE NOTE 4
CONTAINMENT AREA
NEW TEMPORARY
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
AUTO-TRANSFORMER
BANK 'E'
TRANSFORMER
UNTANKING
HOUSE
AREA
NEW CONTAINMENT
AREA
NEW CONTAINMENT
SWITCHYARD ACCESS GATE
UNTANKING HOUSE
TRANSFORMER
TUNNEL
EXISTING CABLE
SEE NOTE 3
SEE NOTE 3
SEE NOTE 4
CONTAINMENT AREA
NEW TEMPORARY
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
LOCATION
APPROXIMATE
RECEPTACLE
120VAC
CONTAINMENT AREA.
CONTAINMENT TO REACH ALL AREAS OF THE TEMPORARY
AREA. PROVIDE ADEQUATE SLACK AT THE TEMPORARY
GROUND MAT TO THE EDGE OF THE TEMPORARY CONTAINMENT
5. PROVIDE A #4/0 GROUND CONDUCTOR FROM THE SWITCHYARD
PLACEMENT PER SECTION 31 00 00.00 26
PREPARE GROUND SURFACE FOR TEMPORARY CONTAINMENT
TEMPORARY CONTAINMENT PLACEMENT. EXCAVATE AND
FOR A MORE DETAILED VIEW OF THE NEW CONTAINMENT AND
A 54' BY 14' TEMPORARY OIL CONTAINMENT BERM. SEE S-101
4. THE TEMPORARY CONTAINMENT AREA MUST ACCOMMODATE
OR BE OF NON-CONDUCTIVE MATERIAL.
GROUNDED TO PROVIDE SAFE TOUCH VOLTAGE PER IEEE 80
TRANSFORMER STORAGE AREA. TEMPORARY FENCE MUST BE
INSTALLATION. PROVIDE TEMPORARY FENCE AROUND THE
CONDITION AFTER COMPLETION OF THE TRANSFORMER
REINSTALLED AND GROUNDED BACK TO ITS ORIGINAL
AND TRANSFORMER INSTALLATION. FENCE MUST BE
TO ACCOMMODATE TEMPORARY TRANSFORMER STORAGE
3. REMOVE EXISTING FENCE EAST OF EACH TRANSFORMER
TEMPORARY CONTAINMENT AREA.
TEMPORARY CONTAINMENT TO REACH ALL AREAS OF THE
SPECIFICATIONS. PROVIDE ADEQUATE SLACK AT THE
CONTAINMENT AREA IN ACCORDANCE TO NFPA 70 AND THE
POWER LOCATIONS IDENTIFIED TO THE EDGE OF TEMPORARY
2. PROVIDE AND ROUTE TEMPORARY POWER FROM THE 120VAC
PROVIDED BY THE TRANSFORMER SUPPLY CONTRACTOR.
PER SPECIFICATIONS. OIL CONTAINMENT WILL BE
1. TEMPORARY CONTAINMENT AREA MUST BE PREPARED
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10 11 12 13
H
J
SHEET ID
F
IL
E N
A M
E
D R
A W
IN
G N
O
®of Engineers
US Army Corps ®of Engineers
US Army Corps
D R
A W
IN
G N
O
F
IL
E N
A M
E
P O
R T
L A
N D
O R
E G
O N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
O M
A H
A D
IS
T R
IC
T
G
U T
R A
N S
F O
R M
E R I
N S
T A
L L
S W
IT
C H
Y A
R D
M
IS
S O
U R I
R
IV
E R
F O
R T R
A N
D A
L L D
A M A
N D R
S V
R
W F
R
F
G .0
G -1
.d g n
F R
G -1 .0
-0 /5
E
V A
U G
H N
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
H Y
D R
O E
L E
C T
R
IC
D
E S
IG
N C
E N
T E
R
G-103
S T
E V
E N R
M
IL
E S P .E
A N
S I F
/1
/2
PLAN
NORTH
M T
H O
M P
S O
N
T
M C
G
IL
V R
E Y P .E
L O
C A
T
IO
N S
P
L A
N
T E
M P
O R
A R
Y C
O N
T A
IN
M E
N T A
R E
A
PLAN
NORTH
SCALE: 1" = 30'- 0"
SCALE: 1" = 30'- 0"
NOTES:
SITE PLAN
TRANSFORMER A AND B
SITE PLAN
TRANSFORMER C AND D
TRANSFORMER A
TRANSFORMER B
TRANSFORMER C
TRANSFORMER D
A M
G
E N
E R
A L R
E V
IS
IO
N
-1
-2
| FRG4_1.003_G-103 - Amendment 1 |
| FRG4_1.003_G-103 - Amendment 1 - B&W |
File details come from the government source that posted it. Updated .