Am0002 - Drawings - FR Zebra Mussel.pdf

PDF 786 KB Posted

Attached to
Zebra Mussel Mitigation, Fort Randall Federal contract opportunity
Solicitation number
W9128F21Q0033
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

View the file

Other files for this federal contract opportunity

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

UNIT 8

M

14"6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

M

UNIT 7

6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

T O T

U R

B

IN

E

T O P

E N

S T

O C

K T

U N

N E

L

1"

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S T

O T

A

IL

R A

C E

M

UNIT 6

M

14"6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

M

UNIT 5

6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

T O T

U R

B

IN

E

T O P

E N

S T

O C

K T

U N

N E

L

1"

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S T

O T

A

IL

R A

C E

M

UNIT 4

M

14"6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

M

UNIT 3

6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

T O T

U R

B

IN

E

T O P

E N

S T

O C

K T

U N

N E

L

1"

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S T

O T

A

IL

R A

C E

M

UNIT 2

M

14"6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

T O T

U R

B

IN

E

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S T

O T

A

IL

R A

C E

M

UNIT 1

6"

PS

T O P

O N

D L

IN

E

T O G

E N

A

IR

C

O O

L

IN

G C

O

IL

S

T O G

E N

B E

A R

IN

G C

O O

L E

R

F R

O M G

E N

B E

A R

IN

G C

O O

L E

R

T O T

U R

B

IN

E

T O P

E N

S T

O C

K T

U N

N E

L

6"

2"

M

F R

O M G

E N

A

IR

C

O O

L

IN

G C

O

IL

S T

O T

A

IL

R A

C E

M

T O T

U R

B

IN

E

T O P

E N

S T

O C

K T

U N

N E

L

1"

T O T

A

IL

R A

C E

T O T

U R

B

IN

E

1"

T O T

A

IL

R A

C E

T O T

U R

B

IN

E

T O P

E N

S T

O C

K T

U N

N E

L

1"

T O T

A

IL

R A

C E

EL 1244.0

TANK

SUPPLY

HEATER

WATER

T O A

IR

C

O N

D S -1

D

1"1"

1"

1" 1"

PENSTOCK(TYP. OF 8)

T O P

E N

S T

O C

K T

U N

N E

L

14" RWS

10" RWS

12" RWR

1"

T O E

M E

R

W A

T E

R S

U P

P L

Y

COIL

UNIT S-1K

AIR COND.

TO & FROM

1" RWS/R

C W S

U P

P L

Y

C W R

E T

U R

N

FLOW RATE (GPM) 0 - 33000 0 - 33000 0 - 33000 0 - 33000

1GENERATOR UNIT # 2 3 4 5 6 7 8

0 - 20 0 - 20 0 - 20 0 - 20

(TYP. OF 4)

AND QUILL ASSEMBLY

INJECTION TUBING

ASSEMBLY (TYP. OF 4)

INSERTION TYPE FLOW METER

0 - 4.16

(TYP. OF4)

SPILL CONTAINMENT

CONTROL, SECONDARY

METERING PUMP SKID,

CU. CONCENTRATION(PPB)

LIQUID CBP (ML/MIN) 0 - 4.16 0 - 4.16 0 - 4.16

M

A H

A

N E

F

IL

E N

A M

E

C

A P

IT

O L A

V E

F

IL

E N

U M

B E

R

F R

H

M -1

.d g n

A H

A D

IS

T R

IC

T

F O

R T R

A N

D A

L L D

A M S

O U

T H D

A K

O T

A

Z E

B R

A M

U S

S E

L M

IT

IG

A T

IO

N S

Y S

T E

M

A N

S I

D

K .P

A R

K

K .P

A R

K

R A

W W

A T

E R F

L O

W D

IA

G R

A M

M-101

M-101

N.T.S.

POWERHOUSE RAW WATER FLOW DIAGRAM

PIPING DIAGRAM HEREAFTER OMITTED ON THIS SHEET

AS SCHEMATICALLY SHOWN ON THIS SHEET.

INTAKE SUPPLY LINES AT GENERATOR UNIT #2, #4, #6, #8

EACH SYSTEM IS TO BE INSTALLED IN 14" RAW WATER

SYSTEM ARE TO BE PROVIDED UNDER THIS CONTRACT.

TOTAL FOUR(4) SETS OF LIQUID CBP DISTRIBUTION

C .F

O S

M E

R

C .F

O S

M E

R

A P

R

IL

W F

Q

A

M -G

E N

E R

A L R

E V

IS

IO

N

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

M M M M

M M M M

A H

A

N E

F

IL

E N

A M

E

C

A P

IT

O L A

V E

F

IL

E N

U M

B E

R

F R

H

M -1

.d

A H

A D

IS

T R

IC

T

F O

R T R

A N

D A

L L D

A M S

O U

T H D

A K

O T

A

Z E

B R

A M

U S

S E

L M

IT

IG

A T

IO

N S

Y S

T E

M

A N

S I

D

K .P

A R

K

M-102

PORT

ASSEMBLY AND

INJECTION QUILL

UNIT 1 UNIT 2 UNIT 3 UNIT 4

UNIT 5 UNIT 6 UNIT 7 UNIT 8

CONTRACTION JOINT (TYP)

CONTRACTION JOINT (TYP)

CONTRACTION JOINT (TYP)

MATCH LINE

MATCH LINE

CONTRACTION JOINT (TYP)

& GROUT PAD

COMPRESSED AIR TANK

M-102

3/32"=1'

OVERALL SYSTEM ARRANGEMENT

O V

E R

A L L S

Y S

T E

M A

R R

A N

G E

M E

N T

KEY PLAN

F

L O

W

UNIT 1 UNIT2 UNIT3 UNIT4 UNIT5 UNIT6 UNIT7 UNIT8SUPPORT AREA

N.T.S

DISCONNECT (TYP. OF 4)

FURNISHED 110/240 VAC

GOVERNMENT

ASSEMBLY

METER

TYPE FLOW

INSERTION

K .P

A R

K A

P R

IL

70'-0" 70'-0"70'-0"70'-0"

73'-0"70'-0"70'-0"70'-0"

22'-0"

& SECTIONS

ENLARGED PLAN

M-103 FOR

SEE SHEET

CONTRACTION JOINT (TYP)

CONTRACTION JOINT (TYP)

C .F

O S

M E

R

C .F

O S

M E

R

PUMP MOTORS

AHU AND DUCTWORK (TYP. OF 8)

DOWNSTREAM SIDE CORRIDOR

EQUIPMENT IMPASSABLE THRU

DOWNSTREAM SIDE CORRIDOR

EQUIPMENT IMPASSABLE THRU

RELOCATED BY GOVERNMENT.

EXTINGUISHER TO BE

WALL MOUNTED EXISTING FIRE

ITEMS ON THE WALL.

TO AVOID INTERFERENCE WITH EXISTING

SHIFT SYSTEM APPROX. 10 FT TO PLAN EAST

EACH AHU AND DUCKWORK.

WALL MOUNTED ITEMS SUCH AS PIPING, CONDUITS, ELECTRICAL PANELS, AND ETC. NEAR

BE COORDINATED ON SITE WITH O&M MANAGER TO AVOID INTERFERENCES WITH VARIOUS

STRUCTURES ON THE EQUIPMENT FLOOR (EL 1244.0). FINAL EQUIPMENT LOCATIONS SHALL

INJECTION SYSTEM, BUT DOES NOT SHOW ALL EXISTING EQUIPMENT, PIPING, AND OTHER

NOTE: THIS SHEET DEPICTS TENTATIVE LOCATION AND ARRANGEMENT OF EACH CHEMICAL

W F

Q

A M

-G

E N

E R

A L R

E V

IS

IO

N

CHEMICAL TOTES.

#6, AND #8) EXCLUDING 275 GALLONS

(TOTAL FOUR (4) SETS FOR UNIT # 2, #4,

CONTAINMENT AND METERING PUMP SKID

SYSTEM-SECONDARY SPILL

LIQUID CBP DISTRIBUTION

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

A N

S I

D

A H

A

N E

F

IL

E N

A M

E

C

A P

IT

O L A

V E

F

IL

E N

U M

B E

R

F R

H

M -1

.d

A H

A D

IS

T R

IC

T

F O

R T R

A N

D A

L L D

A M S

O U

T H D

A K

O T

A

Z E

B R

A M

U S

S E

L M

IT

IG

A T

IO

N S

Y S

T E

M

A N

S I

D

K .P

A R

K

K .P

A R

K

M-103

M-103

3/8"=1'

M-103

3/8"=1'

M-103

3/16"=1'

TYPICAL INSTALLATION- PLAN VIEW

SECTION VIEW-A

SECTION VIEW-B

EQUIPMENT FLOOR EL.1244.0

EQUIPMENT FLOOR EL.1244.0

EQUIPMENT FLOOR EL.1244.0

BY CONTRACTOR

ELECTRICAL CONNECTION

CONTAINMENT

SPILL

SECONDARY

CONTAINMENT

SPILL

SECONDARY

PUMP SKID

METERING

SS RIGID TUBING

SS RIGID TUBING SS RIGID TUBING

SS RIGID TUBING

CONTAINMENT

SPILL

SECONDARY

MECHANICAL KEYNOTES

RECOMMENDATIONS. PROVIDE SUFFICIENT NUMBER OF ISOLATION VALVES, UNIONS, AND FLEX TUBING TO ALLOW PUMP REPLACEMENT.

INSTALL METERING PUMP WALL SKID USING NECESSARY HARDWARE IN ACCORDANCE WITH PUMP SKID MANUFACTURER'S

SUPPORT STAINLESS STEEL CHEMICAL INJECTION TUBING FROM THE EXISTING PIPE RACK.

STEEL CLEVIS STYLE HANGERS, RODS, BOLTS, AND NUTS, AND/OR BEHRINGER/STAUFF STYLE CLAMPS.

TUBING SUPPORTS SHALL BE STAINLESS

COMPLETE FINAL ELECTRICAL CONNECTIONS. ALL ELECTRICAL WORK SHALL BE IAW NFPA 70.

PROVIDE ALL NECESSARY TRANSFORMERS, RECTIFIERS, AND PRE-WIRED JUNCTION BOXES, CONDUITS, CABLES, AND WIRING TO

A P

R

IL

CHEMICAL DISTRIBUTION TUBING

316L STAINLESS STEEL

AND CONTROL

PUMP SKID

METERING

CONNECTION

ELECTRICAL

AND QUILL ASSEMBLY

INJECTION PORT

VALVES

ISOLATION

TUBING W/

SS FLEX

VALVES

W/ ISOLATION

SS FLEX TUBING

W/ ISOLATION VALVE

FLOW METER ASSEMBLY

INSERTION TYPE

VALVE

W/ ISOLATION

ASSEMBLY

FLOW METER

INSERTION TYPE

VALVES

W/ ISOLATION

SS FLEX TUBING

VALVES

W/ ISOLATION

SS FLEX TUBING

VALVES

W/ ISOLATION

SS FLEX TUBING

W/ ISOLATION VALVE

FLOW METER ASSEMBLY

INSERTION TYPE

8'-3"13'-9"

10'-0"

TURBINE PIT

AHU

OIL COOLER

& GEN. BEARING

3" TO TURBINE BEARING

OIL COOLER

FROM GEN. BEARING

2" TO TURBINE BEARING

14" GATE VALVE

14" MOTORIZED ISOLATION VALVE

14" RWS

14" DUPLEX STRAINER

12" RWR

14" RWS

13 FT ABOVE FLOOR

CL. PIPES APPROX.

(NEAR EACH PUMP SKID)

120/240VAC DISCONNECT

GOVERNMENT FURNISHED

AND CONTROL

PUMP SKID

METERING

WORK.

MUST BE READABLE FROM PERSON STANDING ON FLOOR. RESTORE THE INSULATION TO ORIGINAL STATE AFTER COMPLETE THE

4-20 mA ANALOG (FLOW RATE) INPUT TO/FROM PUMP CONTROLLER TO MODULATE THE LIQUID CBP INJECTION RATE. LOCAL DISPLAY

PERFORM NECESSARY HOT WORK ON 14" RAW PIPE AND PROVIDE INSERTION TYPE MAGNETIC FLOWMETER (LOOP POWERED). PROVIDE

BEHRINGER/STAUFF STYLE CLAMPS. .

SECURE TUBING AND METERING PUMP SKID TO WALL USING WEDGE TYPE EXPANSIVE CONCRETE ANCHORS, BRACKETS, AND/OR

C .F

O S

M E

R

T Y

P

IC

A L I

N S

T A

L L

A T

IO

N P

L A

N A

N D S

E C

T

IO

N V

IE

W S

C .F

O S

M E

R

DISCONNECT

120/240VAC

FURNISHED

GOVERNMENT

MAIN RW HEADER

PIPE RACK AND BELOW

ROUTE TUBING ABOVE

W F

Q

INJECTION PORT

QUILL ASSEMBLY AND

CHEMICAL INJECTION

AFTER COMPLETE THE WORK.

INJECTION QUILL WITHOUT THE RAW WATER SYSTEM SHUTDOWN IN THE FUTURE. SECURE TUBING TO WALL. RESTORE THE INSULATION

ISOLATION VALVES, FLEXIBLE TUBING, AND UNIONS IN THE VERTICAL SECTION ABOVE TO ALLOW REPAIR/ REPLACEMENT OF THE

QUILL MUST BE APPROXIMATELY TO THE CENTERLINE OF THE 14" RAW WATER SUPPLY PIPE. PROVIDE SUFFICIENT NUMBER OF

ISOLATION VALVE TO INSTALL INJECTION QUILL. INSTALL INJECTION QUILL PER MANUFACTURER'S STANDARD. INSERT DEPTH OF THE

PERFORM NECESSARY HOT WORK ON 14" RAW WATER PIPE AND PROVIDE MINIMUM 1" THREADED INJECTION PORT WITH FULL PORT

CONTRACT)

INCLUDED IN THIS

CBP TOTE(NOT

275 GALLONS LIQUID

THIS CONTRACT)

INCLUDED IN

TOTE(NOT

LIQUID CBP

AND 8500 LBS LOAD CAPACITY.

SECONDARY SPILL CONTAINMENT MUST HAVE A VALVED DRAIN, 110% OF SUMP CAPACITY (BASED ON 275 GALLONS CHEMICAL VOLUME), THIS CONTRACT)

INCLUDED IN

TOTE(NOT

LIQUID CBP

A M

-G

E N

E R

A L R

E V

IS

IO

N

B

M-103

A

M-103

FRH2M-101
FRH2M-102
FRH2M-103

File details come from the government source that posted it. Updated .