Amendment 1 Explosives Site Plan
ESTCP LIVE DEMONSTRATION PROJECT
SOLID WASTE MANAGEMENT UNIT 7
PUEBLO CHEMICAL DEPOT, PUEBLO, COLORADO
March 2016
Prepared by
Summit Technical Resources-TLI Solutions Joint Venture
For
U.S. Army Corps of Engineers Omaha District, Omaha, NE i
TABLE OF CONTENTS
1.0 SITE
2.0 ANTICIPATED DATES
3.0 PURPOSE
4.0 SITE BACKGROUND AND CURRENT CONDITIONS
5.0 EXECUTING AGENCIES
6.0 SCOPE OF INVESTIGATIVE/CHARACTERIZATION ACTION
7.0 SAFETY CRITERIA
8.0 METHODS OF DISPOSAL
APPENDIX A Maps
APPENDIX B Fragmentation Data Review Forms
Introduction:
This submittal is Amendment 1 to the DDESB-approved Explosive Site Plan for the ESTCP
Demonstration Project Solid Waste Management Unit 7, Pueblo Chemical Depot, Colorado
(Parsons Government Services, Inc., 2015), hereafter referred to as the “approved ESP”.
This Amendment 1 to the Explosives Site Plan (ESP) supersedes all affected sections of the approved ESP as documented in this amendment. All changes and additions to the approved ESP are in bold type-face.
The United States Army Corps of Engineers (USACE) Omaha District has prepared this amendment in response to:
The need for the USACE to contract the anomaly reacquisition and intrusive investigation phase of the Environmental Security Technology Certification
Program (ESTCP) demonstration project and assignment to a new contractor;
Update on the anticipated start date for anomaly reacquisition and intrusive investigation;
Additional safety criteria reference required for USACE Engineering Manual 385-
1-97;
Update and clarifications needed on the methods of disposal; and
Update of the Fragmentation Data Review Forms provided in the approved ESP.
The project objective is to support the ESTCP Munitions Response Live Site
Demonstrations program with intrusive investigation results.
1.0 Site:
No change.
2.0 Anticipated Dates:
a. Start: May 2016.
3.0 Purpose:
No change.
4.0 Site Background and Current Conditions:
No change.
5.0 Executing Agencies:
a. No change
b. No change
c. No change
d. Contractors
6.0 Scope of Investigative Action:
a. The Demonstration Project will include investigation of approximately 8 acres of the 53-acre SWMU 7 site in a series of 8-meter (m) wide transects spaced at 45-m intervals across the site. The following will be performed within the survey transects:
1) A surface sweep will be performed prior to digital geophysical mapping
(DGM) data collection. The surface sweep will include the removal of any identified MEC and any large pieces of metal on the surface which would affect the results of the DGM and classification surveys. It will only be performed over the areas that will be subject to subsequent DGM survey;
2) Blind seeding of either inert munitions or industry standard objects designed to geophysically resemble munitions. Anomaly avoidance procedures will be followed during seeding;
3) DGM data collection using the MetalMapper advanced electromagnetic induction sensor. Anomalies will be identified in the collected data for further investigation via a cued survey also to be performed with the
MetalMapper;
4) Cued MetalMapper data will be collected over the anomalies identified in the DGM survey, and the cued data will be analyzed to construct a ranked dig list that separates anomalies likely to be targets of interest (TOI; MEC, MEC-like munitions debris, and seed items) from anomalies unrelated to
MEC;
5) Intrusive investigation will be performed to allow for ground truth of specific anomalies as requested by data analysts. This ESP amendment clarifies that a different contractor will be performing the intrusive investigation. Phases 1) through 4) above were completed under the approved ESP.
b. No change.
7.0 Safety Criteria:
No change.
a. No change.
b. No change.
c. No change.
d. No change.
e. All Material Potentially Presenting Explosive Hazard (MPPEH) procedures will be in accordance with DoD 4140.62 and USACE Engineer Manual (EM) 385-1-97. All
MPPEH will be assessed and its explosive safety status determined and documented prior to transfer within DoD or release from DoD control. Prior to release to the public, MPPEH will be documented by authorized and technically qualified personnel as Material Documented as Safe (MDAS) after 100% inspection and an independent
100% re-inspection to determine that it is safe from an explosives safety perspective.
f. No change.
Table 7-1
Minimum Separation Distances (MSD)
(No change)
8.0 Methods of Disposal:
a. No change.
b. No change.
c. Tamping (single or multiple items) may be used IAW DDESB TP 16 and the BEM version 6.3.3 or later, if released. The reports will be available on site for all mitigation methods used.
d. Explosives will be provided by an on-call licensed local explosives vendor on an as-needed basis. MEC will be marked and guarded until disposal is accomplished. Explosives will not be stored on site at any time.
e. No change.
f. No change
g. No change
h. The UXO Team will normally detonate munitions encountered, in place. The exception is when technically qualified personnel who are performing the functions of the Senior Unexploded Ordnance Supervisor (SUXOS) and
Unexploded Ordnance Safety Officer (UXOSO) determine that the risk associated with movement is acceptable, and movement is necessary for the protection of people, property, or critical assets, or the efficiency of the activities being conducted. In such cases, the SUXOS and UXOSO responsible for the
MEC activities may evaluate the munition and authorize its movement within the sited MRS.
A-1
APPENDIX A
(No Change)
B-1
APPENDIX B
Fragmentation Data Review Forms
1. Projectile, 155 mm, High Explosive (HE), M101 (TNT)
2. Projectile, 155 mm, High Explosive (HE), M107 (Comp B)
3. Projectile, 155 mm, High Explosive (HE), M107 (TNT)
Munition Information and Fragmentation Characteristics
Theoretical Calculated Fragment Distances
Minimum Thickness to Prevent Perforation
Overpressure Distances
Sandbag and Water Mitigation Options
Fragmentation Data Review Form
Category: Surface-Launched HE Rounds
Munition: 155 mm M101
Case Material: Steel, Mild
Secondary Database Category: Projectile
Munition Case Classification: Robust
DODIC: D485
Individual Last Updated Record:
Explosive Type: TNT
Explosive Weight (lb): 14.6
Diameter (in): 6.1250
Maximum Fragment Weight (Intentional) (lb):
1.0548
Critical Fragment Velocity (fps): 4035
HFD [Hazardous Fragment Distance: distance to no more than 1 hazardous fragment per 600 square feet] (ft):
MFD-V [Maximum Fragment Distance, Vertical] (ft): 2208
MFD-H [Maximum Fragment Distance, Horizontal] (ft): 2894
Inhabited Building Distance (1.2 psi), K40 Distance: 98
Unbarricaded Intraline Distance (3.5 psi), K18 Distance: 44
Intentional MSD (0.0655 psi), K328 Distance: 802
4000 psi Concrete (Prevent Spall): 14.62
Mild Steel: 2.82
Hard Steel: 2.31
Aluminum: 5.39
LEXAN: 11.10
Plexi-glass: 9.91
Bullet Resist Glass: 9.14
Kinetic Energy 10⁶ (lb-ft²/s²): 6.6543
Required Wall & Roof Thickness (in) Not Permitted
Expected Max. Throw Distance (ft): Not Permitted
Minimum Separation Distance (ft): Not Permitted
Water Containment System: Not Permitted
Minimum Separation Distance (ft): Not Permitted
Date Record Created: 12/8/2010
Last Date Record Updated: 7/11/2011
Date Record Retired:
Database Revision Date 9/22/2015
Intentional Unintentional
Design Fragment Weight (95%) (Unintentional) (lb):
0.2710
7.33
2.85
1.43
1.17
7.30
4.99
5.69
Distribution authorized to the Department of Defense and U.S. DoD contractors only for Administrative-Operational Use (17 October 2002). Other requests shall be referred to the Chairman, Department of Defense Explosives Safety Board, Room 856C, Hoffman
Building I, 2461 Eisenhower Avenue, Alexandria, VA 22331-0600.
Fragmentation Method: Naturally Fragmenting
Record Created By: MMC
Public Traffic Route Distance (2.3 psi); K24 Distance: 59
TNT Equivalent (Pressure): 1
TNT Equivalent Weight - Pressure (lbs): 14.600
Item Notes
This is the same as the TNT filled 155 mm M107 except that the M101 has a wider rotating band. Therefore the model for the TNT filled 155 mm M107 was used for this round.
TNT Equivalent (Impulse): 1
TNT Equivalent Weight - Impulse (lbs): 14.600
Cylindrical Case Weight (lb): 73.50184
Required Wall & Roof Thickness (in) Not Permitted
Expected Max. Throw Distance (ft): Not Permitted
Minimum Separation Distance (ft): Not Permitted
Single Sandbag Mitigation
Double Sandbag Mitigation
Note: Per V5.E3.2.2.1 of DoD 6055.09-M the minimum sited K328 distance may be no smaller than 200 ft.
Water Mitigation
Note: Use Sandbag and Water Mitigation in accordance with all applicable documents and guidance. If a donor charge larger than 32 grams is utilized, the above mitigation options are no longer applicable. Subject matter experts may be contacted to develop site specific mitigation options.
Theoretical Calculated Fragment Distances
Minimum Thickness to Prevent Perforation
Overpressure Distances
Sandbag and Water Mitigation Options
Fragmentation Data Review Form
Category: Surface-Launched HE Rounds
Munition: 155 mm M107 (Composition B filled)
Case Material: Steel, Mild
Secondary Database Category: Projectile
Munition Case Classification: Robust
DODIC: D571
Individual Last Updated Record: SDH
Explosive Type: Composition B
Explosive Weight (lb): 15.448
Diameter (in): 6.1024
Maximum Fragment Weight (Intentional) (lb):
0.6641
Critical Fragment Velocity (fps): 3584
HFD [Hazardous Fragment Distance: distance to no more than 1 hazardous fragment per 600 square feet] (ft):
MFD-V [Maximum Fragment Distance, Vertical] (ft): 2022
MFD-H [Maximum Fragment Distance, Horizontal] (ft): 2630
Inhabited Building Distance (1.2 psi), K40 Distance: 105
Unbarricaded Intraline Distance (3.5 psi), K18 Distance: 47
Intentional MSD (0.0655 psi), K328 Distance: 858
4000 psi Concrete (Prevent Spall): 14.45
Mild Steel: 2.74
Hard Steel: 2.25
Aluminum: 5.30
LEXAN: 10.69
Plexi-glass: 9.43
Bullet Resist Glass: 8.58
Kinetic Energy 10⁶ (lb-ft²/s²): 5.4935
Required Wall & Roof Thickness (in) 36
Expected Max. Throw Distance (ft): 220
Minimum Separation Distance (ft): 220
Water Containment System: 1100 gal tank
Minimum Separation Distance (ft): 275
Date Record Created: 9/21/2004
Last Date Record Updated:
Date Record Retired:
Database Revision Date 9/22/2015
Intentional Unintentional
Design Fragment Weight (95%) (Unintentional) (lb):
0.1372
6.68
2.61
1.29
1.06
6.73
4.39
5.10
Distribution authorized to the Department of Defense and U.S. DoD contractors only for Administrative-Operational Use (17 October 2002). Other requests shall be referred to the Chairman, Department of Defense Explosives Safety Board, Room 856C, Hoffman
Building I, 2461 Eisenhower Avenue, Alexandria, VA 22331-0600.
Fragmentation Method: Naturally Fragmenting
Record Created By: MC
Public Traffic Route Distance (2.3 psi); K24 Distance: 63
TNT Equivalent (Pressure): 1.16
TNT Equivalent Weight - Pressure (lbs): 17.920
Item Notes
TNT Equivalent (Impulse): 1.14
TNT Equivalent Weight - Impulse (lbs): 17.611
Cylindrical Case Weight (lb): 73.50184
Required Wall & Roof Thickness (in) Not Permitted
Expected Max. Throw Distance (ft): Not Permitted
Minimum Separation Distance (ft): Not Permitted
Single Sandbag Mitigation
Double Sandbag Mitigation
Note: Per V5.E3.2.2.1 of DoD 6055.09-M the minimum sited K328 distance may be no smaller than 200 ft.
Water Mitigation
Note: Use Sandbag and Water Mitigation in accordance with all applicable documents and guidance. If a donor charge larger than 32 grams is utilized, the above mitigation options are no longer
Theoretical Calculated Fragment Distances
Minimum Thickness to Prevent Perforation
Overpressure Distances
Sandbag and Water Mitigation Options
Fragmentation Data Review Form
Category: Surface-Launched HE Rounds
Munition: 155 mm M107 (TNT filled)
Case Material: Steel, Mild
Secondary Database Category: Projectile
Munition Case Classification: Robust
DODIC: D571
Individual Last Updated Record:
Explosive Type: TNT
Explosive Weight (lb): 14.6
Diameter (in): 6.1024
Maximum Fragment Weight (Intentional) (lb):
1.0548
Critical Fragment Velocity (fps): 4035
HFD [Hazardous Fragment Distance: distance to no more than 1 hazardous fragment per 600 square feet] (ft):
MFD-V [Maximum Fragment Distance, Vertical] (ft): 2208
MFD-H [Maximum Fragment Distance, Horizontal] (ft): 2894
Inhabited Building Distance (1.2 psi), K40 Distance: 98
Unbarricaded Intraline Distance (3.5 psi), K18 Distance: 44
Intentional MSD (0.0655 psi), K328 Distance: 802
4000 psi Concrete (Prevent Spall): 14.62
Mild Steel: 2.82
Hard Steel: 2.31
Aluminum: 5.39
LEXAN: 11.10
Plexi-glass: 9.91
Bullet Resist Glass: 9.14
Kinetic Energy 10⁶ (lb-ft²/s²): 6.6543
Required Wall & Roof Thickness (in) Not Permitted
Expected Max. Throw Distance (ft): Not Permitted
Minimum Separation Distance (ft): Not Permitted
Water Containment System: Not Permitted
Minimum Separation Distance (ft): Not Permitted
Date Record Created: 2/4/2010
Last Date Record Updated:
Date Record Retired:
Database Revision Date 9/22/2015
Intentional Unintentional
Design Fragment Weight (95%) (Unintentional) (lb):
0.2710
7.33
2.85
1.43
1.17
7.30
4.99
5.69
Distribution authorized to the Department of Defense and U.S. DoD contractors only for Administrative-Operational Use (17 October 2002). Other requests shall be referred to the Chairman, Department of Defense Explosives Safety Board, Room 856C, Hoffman
Building I, 2461 Eisenhower Avenue, Alexandria, VA 22331-0600.
Fragmentation Method: Naturally Fragmenting
Record Created By: SDH
Public Traffic Route Distance (2.3 psi); K24 Distance: 59
TNT Equivalent (Pressure): 1
TNT Equivalent Weight - Pressure (lbs): 14.600
Item Notes
TNT Equivalent (Impulse): 1
TNT Equivalent Weight - Impulse (lbs): 14.600
Cylindrical Case Weight (lb): 73.50184
Required Wall & Roof Thickness (in) Not Permitted
Expected Max. Throw Distance (ft): Not Permitted
Minimum Separation Distance (ft): Not Permitted
Single Sandbag Mitigation
Double Sandbag Mitigation
Note: Per V5.E3.2.2.1 of DoD 6055.09-M the minimum sited K328 distance may be no smaller than 200 ft.
Water Mitigation
Note: Use Sandbag and Water Mitigation in accordance with all applicable documents and guidance. If a donor charge larger than 32 grams is utilized, the above mitigation options are no longer