Plans_Consolidated_Dormitory_Cavalier_AFS_2_of_3.pdf
PDF 7 MB Posted
- Attached to
- Consolidated Dormitory at Cavalier AFS, ND Federal contract opportunity
- Solicitation number
- W9128F-17-B-0003
About this file
Plans 2 of 3
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| ABSTRACT_-IFB_W9128F-_17-B-0003.pdf | ||
| Am_0002.pdf | ||
| Am_0002-Drawing.pdf | ||
| Site_Visit_Attendee_List.pdf | ||
| Am_0001.pdf | ||
| Specs_Consolidated_Dormitory_Cavalier_AFS_1_of_2.pdf | ||
| Plans_Consolidated_Dormitory_Cavalier_AFS_1_of_3.pdf | ||
| Specs_Consolidated_Dormitory_Cavalier_AFS_2_of_2.pdf | ||
| Plans_Consolidated_Dormitory_Cavalier_AFS_3_of_3.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
D
2 3
C
4 5
A
B
M A
R K
A P
P R
D A
T E
F
IL
E N
U M
B E
R
S
IZ
E
S U
B M
IT
T E
D B
Y
P L
O T S
C A
L E
P L
O T D
A T
E
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
C O
N T
R A
C T N
O
IDENTIFICATION
SHEET
D A
T E
A P
P R
®of Engineers
US Army Corps of Engineers
US Army Corps
OMAHA DISTRICT
ES501 NOT TO SCALE
1 CONDUIT DUCTBANK
ES501 NOT TO SCALENOT TO SCALE
BOLLARD DETAILS
NOT TO SCALE
ES501 NOT TO SCALE
2 CONDUIT DUCTBANK
NOT TO SCALEES501 NOT TO SCALENOT TO SCALE
ES501 NOT TO SCALE
3 PHASE PADMOUNT TRANSFORMER
H1 H2 H3
H1A
H2A
H3A
H1B
H2B
H3B
X1
X2
X3
XO
M in
PAD & CONDUIT LAYOUT (TYP)
1"
IN TRANSFORMER
SECONDARY BARRIER
DESIGN SPECIFIC
4" SECONDARY CONDUITS
WITH BELL END WHEN REQURED
3/4" CT METERING CONDUIT
GROUND ROD 3/4" X 10'
WITH END BELL
4" PRIMARY CONDUITS
IN WINDOW
4" DEEP PEA GRAVEL
IN OPENING USE
DO NOT POUR CONCRETE
GROUND LOOP DETAIL
TRANSFORMER TANK
TOP VIEW
CONDUIT
PRIMARY
CONDUIT
SECONDARY
After Torqued Protrusion Max 1" Bolt
Bushing Transformer
To
W/ELSP CURRENT LIMITING FUSE
INTERNAL BAY-O-NET FUSING
3 LOAD BREAK SWITCHES
INTERNAL LOOP FEED
W/ ELS-P CURRENT LIMITING FUSE
BAY-O-NET OIL IMMERSED IN SERIES
TAP CHANGER
"3 SWITCH"
200 AMP LOAD BREAK
GAUGES TYP
ARRESTER REQUIRED (TYP OF 3)
DATA TAG
RULE 350F
GROUND NESC
CU LOOP
MIN. # 2
GROUND ROD 3/4" X 10'
GRADE
LINE
(NEMA)
(N E
M A
1 - 3 /4 "
TEST POINT ALL ELBOWS
MAXIMUM CONDUIT 3" ABOVE PAD
PROVIDE 200 AMP INSERTS
BURNDY TYPE KC OR EQUAL
GROUNDING CONNECTOR
MECHANICAL TRANSFORMER
SEE NOTE 3
FOAM SEAL ALL CONDUITS
TRANSFORMER GROUND
MECHANICAL TYPE KC
3/4" X 10" GROUND ROD
CLOSING BOLT
PENTAGON HEAD
Plated Steel Hex Nut Lock Washer Flat Washer 1 5/8"OD Steel Bolt 1 / 2" Plated
CONNECTIONS
ALL MECHANICAL
GROUND ROD TO
CONTINUES FROM
#2 GROUND LOOP
CLARITY. SEE EP601 FOR REQUIREMENTS.
SECONDARY CONNECTION NOT SHOWN FOR
ARRESTER GROUNDS
CABLE SHEILDS
GRADE LINE
(MIN)
18" DIA.
CONDUIT)
(CONTRACTOR SHALL CAP
ROD CONNECTION BY OTHERS
SPARE CONDUIT FOR GROUND
ANCHOR BOLTS AS REQ'D
REBAR, 4-#4
#3 TIES
ANCHOR FIXTURE
OUTLINE OF CONCRETE
MANUFACTURER
AND LOCATION PER
ANCHOR BOLT SIZE
18" DIA. BASE (MIN)
BASE PLATE R 1/4" X 8" (NOM) X 8" (NOM)
BOLLARD BOLT PATTERN
THREADED INSERT TO
LOCATION TO BE PROVIDED
BY FIXTURE MANUFACTURER
BOLLARD - TOP VIEW
BALLAST BOX
BOLLARD
LIGHT FIXTURE
8"
(NOMINAL)
FIXTURES
SITE LIGHTING
MATCH OTHER
BRONZE TO
SHALL BE DARK
BOLLARD FINISH
BOLLARD
TO ADJACENT
BRANCH CIRCUIT
3/4"C
2P
3" 3" 3"
B U
IL
D
IN
G
F O
O T
IN
G S
F
T
G
E T U
N D
E R
A
S R
E Q
U
IR
E D
FINISHED GRADE
CONCRETE ENCASEMENT
(2) 4" CONDUITS.
SELECT SOIL BACKFILL
SPARE
TRACER WIRE
LABELED "ELECTRIC"
WARNING TAPE
SHEET EP601
INDICATED ON ONE-LINE. SEE
CABLES SIZE AND NUMBER AS
RACEWAYS USED. TYPICAL.
DUCT SPACER. SIZE FOR
1C
3" 3"
FINISHED GRADE
CONCRETE ENCASEMENT
4" CONDUIT
SELECT SOIL BACKFILL
TRACER WIRE
(3)1-1/4" INNER DUCTS IN RACEWAY.
"TELECOMMUNICATIONS"
WARNING TAPE LABELED
RACEWAYS USED. TYPICAL.
DUCT SPACER. SIZE FOR
OMAHA DISTRICT
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
A F -3
-0
O M
A H
A D
IS
T R
IC
T
N D
E
S .d g n
C O
N S
O L
ID
A T
E D D
O R
M
IT
O R
Y
C A
V A
L
IE
R A
F S
N D
/0
/2
W F -1
-B -0
ES501
A N
S I
D
S L
O
P F
W
P F
W
S L
O
E L E
C T
R
IC
A L S
IT
E D
E T
A
IL
S
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A
N E
B R
A S
K A
A F -3
-0
O M
A H
A D
IS
T R
IC
T
N D
E
S .d g n
C O
N S
O L
ID
A T
E D D
O R
M
IT
O R
Y
C A
V A
L
IE
R A
F S
N D
/0
/2
W F -1
-B -0
ES501
A N
S I
D
S L
O
P F
W
P F
W
S L
O
E L E
C T
R
IC
A L S
IT
E D
E T
A
IL
S
ES501 NOT TO SCALE
1 CONDUIT DUCTBANK
ES501 NOT TO SCALENOT TO SCALE
BOLLARD DETAILS
NOT TO SCALE
ES501 NOT TO SCALE
2 CONDUIT DUCTBANK
NOT TO SCALEES501 NOT TO SCALENOT TO SCALE
ES501 NOT TO SCALE
3 PHASE PADMOUNT TRANSFORMER
ITEM f'c
FREEZE THAW
EXPOSURE
CLASS
SULFATE
EXPOSURE
CLASS
PERMEABILITY CORROSION
PROTECTION
EXTERIOR PAVEMENT, DOOR STOOPS 4.5 KSI F3 S0 P0 C2
ALL OTHER CONCRETE 4.5 KSI F2 S0 P0 C1
LAP SPLICE LAP SPLICE
LA
P
SP
LI
C E
LA
P
SP
LI
C E
CORNERS
INTERSECTIONS
PLAN
OPTION #1
VERTICAL REINF.
NOT SHOWN
STD. 90° HOOK
WHERE INDICATED
VERTICAL REINF.
NOT SHOWN
PLAN
OPTION #2
STD. 90° HOOK
WHERE INDICATED
CORNER BAR
U.N.O.
STD. 90° HOOK
NOT SHOWN
VERTICAL REINF.
PLAN
WITHOUT CJ
STD. 90° HOOK
U.N.O.
WITH CJ
PLAN
NOT SHOWN
VERTICAL REINF.
DOWEL
TYP.
NOTE:
UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS THE
OPTION OF REINFORCING CORNERS IN ACCORDANCE WITH
OPTION #1 OR OPTION #2.
NOTE:
UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS THE
OPTION OF CONSTRUCTING INTERSECTIONS WITH OR WITHOUT
CONSTRUCTION JOINTS. REINFORCE PER APPLICABLE DETAIL.
S
#8
#9
#11
#6
#10
#7
1'-6"
1'-4"
1'-9"
2'-2"
1'-11"
8'-11"
5'-7"
8'-0"
1'-6"
3'-10"
6'-4"
3'-2" 1'-2"
2'-7"
7'-2"
1'-11"
LENGTH OR
8 x DIA. OF BAR - #9 TO #11 BARS 10 x DIA. OF BAR - #14 & #18 BARS
INSIDE RADIUS OF HOOK:
6 x DIA. OF BAR - #3 TO #8 BARS
#3
SIZE
#5
DEVELOPMENT LENGTHS
#4
BAR
MIN. EMBEDMENT
7"
1'-0"
9"
2'-0"
#7
#8
#6
#4
#5
#9
4'-9"
5'-4"
2'-3"
#10
#11
SIZE
DEVELOPMENT LENGTH
BAR
REINFORCING DEVELOPMENT AND SPLICES
SPLICE LENGTH
OTHER
#3
TOPOTHER TOP
1'-6"
2'-11"
2'-6"
4'-3"
2'-0"
6'-10"
4'-3"
2'-6"
4'-11"
6'-2"
5'-6"
1'-6"
1'-11"
3'-4"
3'-9"
4'-3"
1'-2"
4'-11"
5'-6"
6'-10"
2'-11"
6'-2"
HOOKED BARS
1. REINFORCING BAR DEVELOPMENT AND LAP SPLICE LENGTH SHALL BE AS SHOWN UNLESS OTHERWISE NOTED
ON THE DRAWINGS.
BEAMS OR COLUMNS:
COVER (EQUAL OR MORE) 1.0bd (BAR DIAMETER) CENTER TO CENTER (C-C) SPACING (EQUAL OR MORE) 2.0bd.
ALL OTHERS:
COVER (EQUAL OR MORE) 1.0bd CENTER TO CENTER SPACING (EQUAL OR MORE) 3.0bd.
2. TOP BARS ARE DEFINED AS HORIZONTAL REINFORCEMENT SUCH THAT MORE THAN 12 INCHES OF FRESH CONCRETE IS CAST
IN THE MEMBER BELOW THE DEVELOPMENT LENGTH OR SPLICE.
3. WHERE DEVELOPMENT AND SPLICE LENGTH DO NOT MEET THE FOLLOWING CONDITIONS DEVELOPMENT ANS SPLICE LENGTHS
A) f'c < 4500 PSI B) fy > 60,000 PSI
C) THE COVER OR C-C BAR SPACING IS NOT AS LISTED ABOVE
D) THE REINFORCING STEEL IS EPOXY COATED
E) LIGHT WEIGHT CONCRETE IS USED.
4. CENTER ON CENTER SPACING (S) IS DEFINED AS BELOW:
- LAPPED REINF.
- MAIN REINF.
OF BAR
12 X DIA.
LE
N
G
TH
D
EV
EL
O
PM
EN
T
LE
N
G
TH
D
EV
EL
O
PM
EN
T
O R
/2 " M
IN
4" X
D
IA
. O F
BA
R
CRITICAL
SECTION
SHALL BE DETERMINED BY ACI 318-11:
F) THE FOLLOWING CONCRETE COVERAGE AND REINFORCING C-C SPACING:
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
A s in di ca te d
2/ 7/
2 0
:3
2 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
K.
R
EP
AS
KE
Y
W .B
O
EC
K
A F7
-3
-0
S-001
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
G E N
ER
A
L
ST
RU
C
T U R
A L
N O
TE
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 0 0
1-
I. DESIGN LOADS
A. DESIGN CODES:
ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
IBC 2012 INTERNATIONAL BUILDING CODE
UFC 3-301-01 STRUCTURAL ENGINEERING (LATEST EDITION)
B. FLOOR LIVE LOAD
1) ATTIC 20 PSF
2) RESIDENTIAL - PRIVATE 40 PSF
3) RESIDENTIAL - PUBLIC 100 PSF
4) MECHANICAL ROOM 125 PSF
C. ROOF LIVE LOAD
1) ROOF CONSTRUCTION 20 PSF
2) ROOF LIVE (DISTRIBUTED OR CONCENTRATED)
a) DISTRIBUTED 20 PSF (REDUCIBLE)
b) CONCENTRATED 300 LBS
D. SNOW LOAD
1) GROUND SNOW, Pg 60 PSF
2) FLAT-ROOF SNOW LOAD, Pf 37.8 PSF
3) EXPOSURE FACTOR, Ce 0.9
4) IMPORTANCE FACTOR, Is 1.0
5) THERMAL FACTOR, Ct 1.0
6) SNOW DENSITY, Y 21.8 PCF
7) UNBALANCED, SLIDING, AND DRIFT: SEE SNOW LOAD DIAGRAMS
E. WIND LOAD
1) BASIC WIND SPEED (3 SECOND GUST) 115 MPH
2) RISK CATEGORY II
3) EXPOSURE CATEGORY C
4) INTERNAL PRESSURE COEFFICIENT, GCpi +/-0.18
5) ROOF AND WALL COMPONENTS AND CLADDING: SEE WIND LOAD DIAGRAMS
F. SEISMIC LOAD
1) RISK CATEGORY II
2) SEISMIC IMPORTANCE CATEGORY, Ie 1.0
3) Ss 0.035g
4) S1 0.015g
5) SITE CLASS D
6) SDS 0.037g
7) SD1 0.024g
8) SEISMIC DESIGN CATEGORY A
9) BASIC SEISMIC FORCE RESISTING SYSTEM:
a) BEARING WALL SYSTEMS: LIGHT-FRAME (WOOD) WALLS SHEATHED WITH WOOD
STRUCTURAL PANELS RATED FOR SHEAR RESISTANCE
10) DESIGN BASE SHEAR 2.82 KIPS
11) SEISMIC RESPONSE COEFFICIENT, Cs 0.006
12) RESPONSE MODIFICATION COEFFICIENT, R 6.5
13) ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
G. GEOTECHNICAL INFORMATION
1) FOUNDATIONS HAS BEEN DESIGNED WITH THE FOLLOWING ASSUMED GEOTECHNICAL SOIL
PROPERTIES. FOUNDATION HAS BEEN VERIFIED WITH THE FINAL GEOTECHNICAL
REPORT PREPARED BY THE GOVERNMENT.
2) FOOTING DEPTH: MINIMUM 8 FEET BENEATH FINISHED EXTERIOR GRADE FOR HEATED
STRUCTURES. 8 FOOT REQUIREMENT IS NOT LISTED IN THE REPORT BUT RATHER
PROVIDED BY THE INSTALLATION.
3) FOOTING TYPE: CONTINUOUS FOOTINGS FOR EXTERIOR WALLS AND THICKENED SLABS
FOR INTERIOR WALLS.
4) NET ALLOWABLE BEARING PRESSURE: 2,000 PSF (ALL FOOTING TYPES)
THIS PRESSURE ASSUMES NOT MORE THAN 2 FEET OF FILL BE ADDED TO THE SITE
TO ACHIEVE FINISHED GRADE. IF MORE THAN 2 FEET OF FILL WILL BE ADDED TO THE
SITE, THE PRESSURE SHALL BE DECREASED BY MULTIPLYING 110 PCF BY EACH FOOT
OF FILL AND SUBTRACTING THIS NUMBER FROM THE ALLOWABLE BEARING PRESSURE.
5) PAVEMENT DESIGN
a) FROST GROUP F3
b) ASPHALT PAVEMENT 5 CBR
c) CONCRETE PAVEMENT 150 PCI
6) ALL COMPACTED FILL INSTALLATION SHALL BE INSPECTED AND APPROVED BY A
REGISTERED GEOTECHNICAL ENGINEER. A REGISTERED GEOTECHNICAL ENGINEER
SHALL INSPECT AND APPROVE BEARING MATERIALS PRIOR TO PLACEMENT OF CONCRETE.
7) BACKFILL AROUND FOUNDATION WALLS SHALL BE PLACED ON EACH SIDE OF THE WALL
IN EQUAL LIFTS.
8) SEE SPECIFICATION SECTION 31 00 00 FOR ADDITIONAL EARTHWORK REQUIREMENTS.
II. GENERAL NOTES
A. REFERENCE ELEVATION 100'-0" = TOP OF FINISHED FLOOR SLAB, SEE CIVIL SHEETS FOR MEAN
SEA LEVEL ELEVATION.
B. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE LOCATIONS OF ALL
EMBEDDED ITEMS, CONDUITS, PIPES, AND OPENINGS.
C. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIRESTOPPING ALL GAPS BETWEEN WALLS
AND OVERLYING FLOORS, DECKING, AND STRUCTURE AS WELL AS OTHER PENETRATIONS AS
REQUIRED BY ARCHITECTURAL, MECHANICAL, AND ELECTRICAL SHEETS, AND BY THE CONTRACT
SPECIFICATIONS.
D. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE BRACING AND SHORING FOR WORK
AT ALL TIMES DURING CONSTRUCTION.
III. REINFORCED CONCRETE
A. DESIGN CODES: BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI-318)
B. MATERIAL STRENGTHS:
1) CONCRETE COMPRESSIVE STRENGTH (f'c) AT 28 DAYS NORMAL WEIGHT:
B. MATERIAL STRENGTHS CONTINUED:
2) REINFORCING STEEL:
BARS (NOT WELDED) ASTM A615, GR. 60 KSI
BARS (WELDED) ASTM A706, GR. 60 KSI
TIES ASTM A615, GR. 60 KSI
WELDED WIRE REINFORCEMENT ASTM A185
C. NOTES
1) ALL CONCRETE OPERATIONS AND REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE
LATEST ACI AND CRSI STANDARDS.
2) REFER TO THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL
EMBEDDED ITEMS AND ACCESSORIES. NO CALCIUM CHLORIDE OR OTHER DELETERIOUS SALTS
ARE PERMITTED IN CONCRETE. NO ALUMINUM EMBEDMENT IS PERMITTED. PROVIDE 3/4"
CHAMFER AT ALL EXPOSED CORNERS.
3) FURNISH THE FOLLOWING CONCRETE COVER ON REINFORCING BARS UNO:
SLAB ON GRADE 1.5" COVER AT TOP
SLABS ON METAL FORMS CENTER MESH IN PORTION OF SLAB
ABOVE METAL FORMS
FOUNDATIONS 3" COVER ON BOTTOM AND SIDES
WALLS 2" UNO
4) PROVIDE THE FOLLOWING CONCRETE FINISHES UNO:
WALLS PER SPECIFICATIONS
FOUNDATIONS PER SPECIFICATIONS
SLABS TO BE EXPOSED PER SPECIFICATIONS
III. REINFORCED CONCRETE CONTINUED...
5) LONGITUDINAL REINFORCING IN THE FOUNDATION SHALL BE PLACED CONTINUOUS
AT CORNERS AND INTERSECTIONS. MATCHING CORNER BARS SHALL BE USED PER
THE TYPICAL CONCRETE REINFORCEMENT DETAILS ON THE CONTRACT DRAWINGS.
6) ALL CONCRETE IS REINFORCED UNLESS SPECIFICALLY CALLED OUT AS UNREINFORCED.
REINFORCE ALL CONCRETE NOT OTHERWISE SHOWN WITH SAME STEEL AS IN SIMILAR
SECTIONS OR AREAS.
7) ALL ADJOINING SURFACES NOT CAST MONOLITHICALLY SHALL BE INTENTIONALLY
ROUGHENED TO 1/4" AMPLITUDE AT EXISTING CONCRETE SURFACE FOR THE ENTIRE
INTERSECTING SURFACE. APPLY BONDING AGENT TO EXISTING CONCRETE PRIOR
TO PLACING NEW CONCRETE.
8) CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL FLOOR DRAINS, FLOOR FINISHES,
CURBS, CONCRETE PADS, AND SLAB DEPRESSIONS WITH ARCHITECTURAL AND
MECHANICAL DRAWINGS.
9) CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND LOCATIONS OF ALL OPENINGS,
PIPE SLEEVES, CURBS, ETC. AS REQUIRED WITH OTHER TRADES PRIOR TO PLACING
CONCRETE.
10) CONTRACTOR SHALL COORDINATE LOCATIONS OF INSERTS AND OTHER ITEMS EMBEDDED
IN CONCRETE WITH ARCHITECTURAL DRAWINGS, MECHANICAL DRAWINGS, AND OTHER
TRADES.
IV. STRUCTURAL STEEL
A. CAST-IN-PLACE ANCHOR RODS: ASTM F1554, GR. 36, UNO
B. WELDING ELECTRODES FOR ALL WORK SHALL BE E70XX.
C. ALL STRUCTURAL STEEL AND THEIR CONNECTIONS SHALL BE DETAILED, FABRICATED, AND ERECTED ACCORDING TO THE LATEST VERSION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
MANUAL OF STEEL CONSTRUCTION.
D. ALL WELDING SHALL BE DONE BY AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS.
V. STRUCTURAL WOOD
A. DESIGN, FABRICATION, AND CONSTRUCTION OF WOOD FRAMING MUST CONFORM WITH:
1) AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC) "TIMBER CONSTRUCTION MANUAL"
(6TH EDITION, 2012).
2) AMERICAN WOOD COUNCIL (AWC) "NATIONAL DESIGN SPECIFICATIONS (NDS)
FOR WOOD CONSTRUCTION" (2012 EDITION).
B. UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS SAWN LUMBER GRADING SHALL BE
AS FOLLOWS:
1) 2X JOISTS DFL-NORTH (OR HF) NO 2
2) PLATES/BLOCKING DFL-NORTH (OR HF) NO 2
3) PLATES ON CONC (PRESSURE TREAT) DFL-NORTH NO 1
4) WALL AND FLOOR SHEATHING DFL-NORTH OR SP
C. GRADE STAMP SHALL BE VISIBLE ON EVERY PIECE OF LUMBER IN PLACE (EXCLUDING BLOCKING).
D. POSTS, STUDS, CHORDS, STRUTS, AND OTHER FRAMING MEMBERS SHALL BE SAWN DOUGLAS-FIR-LARCH (NORTH) NO. 2 OR OTHER GRADE AND SPECIES HAVING THE MINIMUM BASE DESIGN VALUES IN THE NATIONAL DESIGN SPECIFICATION SUPPLEMENT TABLE 4A AS LISTED BELOW (BEFORE APPLYING ADJUSTMENT FACTORS):
1) FB = 850 PSI (BENDING)
2) FT = 500 PSI (TENSION PARALLEL TO GRAIN)
3) FV = 180 PSI (SHEAR PARALLEL TO GRAIN)
4) FC = 1400 PSI (COMPRESSION PARALLEL TO GRAIN)
5) FC (PERP) = 625 PSI (COMPRESSION PERPENDICULAR TO GRAIN)
6) E = 1,600,000 PSI (MODULUS OF ELASTICITY FOR DEFLECTION)
7) EMIN' = 580,000 PSI (MODULUS OF ELASTICITY FOR STABILITY
E. STRUCTURAL GLUED LAMINATED TIMBER (SGLT) SHALL BE HORIZONTALLY LAMINATED MEMBERS
MANUFACTURED IN ACCORDANCE WITH THE "TIMBER CONSTRUCTION MANUAL" OF THE AITC.
1) LUMBER SHALL BE SOUTHERN PINE OR DOUGLAS FIR-KD 24F-1.8E OR OTHER GRADE AND SPECIES HAVING THE MINIMUM BASE DESIGN VALUES IN THE NATIONAL DESIGN SPECIFICATION SUPPLEMENT TABLE 5A AS
LISTED BELOW (BEFORE APPLYING ADJUSTMENT FACTORS):
a) FB = 2400 PSI (POSITIVE BENDING ABOUT X-AXIS)
b) FV = 230 PSI (SHEAR PARALLEL TO GRAIN)
c) FC (PERP) = 650 PSI (COMPRESSION PERPENDICULAR TO GRAIN)
d) E = 1,800,000 PSI (MODULUS OF ELASTICITY FOR DEFLECTION)
e) EMIN' = 950,000 PSI (MODULUS OF ELASTICITY FOR STABILITY
2) ADHESIVES TO BE IN ACCORDANCE WITH AMERICAN NATIONAL STANDARD ANSI/AITC A190.1
F. EXPOSED TRUSSES AND FRAMING IN THE COMMUNITY ROOM AND ON THE ENTRYWAY ROOF CANOPY SHALL BE NORTHERN WHITE CEDAR NO. 1 WITH MINIMUM BASE DESIGN VALUES IN THE NATIONAL DESIGN SPECIFICATION
SUPPLEMENT TABLE 4A AS LISTED BELOW (BEFORE APPLYING ADJUSTMENT FACTORS):
1) FB =575 PSI (BENDING)
2) FT = 325 PSI (TENSION PARALLEL TO GRAIN)
3) FV = 120 PSI (SHEAR PARALLEL TO GRAIN)
4) FC = 600 PSI (COMPRESSION PARALLEL TO GRAIN)
5) FC (PERP) = 370 PSI (COMPRESSION PERPENDICULAR TO GRAIN)
6) E = 700,000 PSI (MODULUS OF ELASTICITY FOR DEFLECTION)
7) EMIN' = 260,000 PSI (MODULUS OF ELASTICITY FOR STABILITY
G. LAMINATED VENEER LUMBER (LVL) USED FOR HEADERS IN BEARING WALLS SHALL HAVE THE MINIMUM ALLOWABLE
STRESSES AS LISTED BELOW:
1) FB =2600 PSI (BENDING)
2) FV = 285 PSI (SHEAR PARALLEL TO GRAIN)
3) FC = 2500 PSI (COMPRESSION PARALLEL TO GRAIN)
4) FC (PERP) = 750 PSI (COMPRESSION PERPENDICULAR TO GRAIN)
5) E = 1,800,000 PSI (MODULUS OF ELASTICITY FOR DEFLECTION)
H. ALL CONNECTIONS FOR JOISTS, BEAMS, TRUSSES, AND MANUFACTURED WOOD FRAMING TO BE MADE
WITH APPROPRIATE METAL HANGARS, FRAMING ANGLES, CONNECTORS, STRAPS, ETC:
1) BOLTS OR LAG SCREWS PER ASTM A325 SPECIFICATIONS
2) NAILS TO BE COMMON NOT BOX (NAILS TO BE GALVANIZED)
3) THE QUANTITY AND SIZE OF NAILS AND OTHER FASTENERS CONNECTING WOOD MEMBERS
MUST NOT BE LESS THAN THE FASTENING SCHEDULE ON SHEET S-002.
I. SPECIAL INSPECTIONS
1) CONTINUOUS SPECIAL INSPECTION DURING ALL FIELD GLUING OF ELEMENTS OF THE LATERAL
FORCE RESISTING SYSTEM IS REQUIRED.
2) PERIODIC SPECIAL INSPECTION IS REQUIRED FOR NAILING, BOLTING, ANCHORING, AND OTHER
FASTENING OF COMPONENTS WITHIN THE MAIN WIND FORCE RESISTING SYSTEM INCLUDING
WOOD SHEAR WALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, AND HOLD-DOWNS.
VI. SPECIAL INSPECTION NOTES (IBC 2012)
A. FABRICATORS PER SECTION 1704.2.
B. SPECIAL INSPECTION IS NOT REQUIRED FOR WORK PERFORMED BY AN APPROVED FABRICATOR PER IBC
SECTION 1704.2.5.2.
C. CONTINUOUS SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON THE SITE AT ALL TIMES OBSERVING THE WORK REQUIRING SPECIAL INSPECTION. PERIODIC SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON SITE AT ALL TIME INTERVALS NECESSARY TO CONFIRM THAT ALL WORK
REQUIRING SPECIAL INSPECTION IS IN COMPLIANCE.
D. ALL WELDS SHALL BE VISUALLY INSPECTED PER AWS D1.1/D1.1M:2010, STRUCTURAL WELDING CODE - STEEL.
E. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE
OF COMPLIANCE.
F. INSPECTION OF DRILLED CONCRETE ANCHORS, INCLUDING EXPANSION AND ADHESIVE GROUTED ANCHORS, SHALL INCLUDE VISUAL VERIFICATION OF DRILLED HOLE DEPTH, SPACING, EDGE DISTANCES AND HOLE CLEANING. FOR GROUTED ANCHORS, GROUT INSTALLATION SHALL BE OBSERVED AND GROUT PRODUCT
G. INCLUDE SPECIAL INSPECTION REQUIREMENTS IN CONTRACTOR'S QUALITY CONTROL (CQC) PLAN.
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
CONNECTION LOCATION
1. JOIST TO SILL OR GIRDER 3 - 8d TOENAIL
INTERNATIONAL BUILDING CODE (IBC) 2012
TABLE 2304.9.1 FASTENING SCHEDULE
COMMON NAILS (1)
2. BRIDGING TO JOIST 2 - 8d TOENAIL EACH END
3. 1" X 6" SUBFLOOR OR LESS TO EACH JOIST 2 - 8d FACE NAIL
4. WIDER THAN 1" X 6" SUBFLOOR TO EACH JOIST 3 - 8d FACE NAIL
5. 2" SUBFLOOR TO JOIST OR GIRDER 2 - 16d BLIND AND FACE NAIL
6. SOLE PLATE TO JOIST OR BLOCKING 16d @ 16" O.C. TOENAIL EACH END
SOLE PLATE TO JOIST OR BLOCKING AT BRACED WALL PANEL 3 - 16d @ 16" O.C. BRACED WALL PANELS
7. TOP PLATE TO STUD 2 - 16d END NAIL
8. STUD TO SOLE PLATE
4 - 8d TOENAIL
2 - 16d END NAIL
9. DOUBLE STUDS 16d @ 24" O.C. FACE NAIL
10. DOUBLE TOP PLATES
16d @ 16" O.C. TYPICAL FACE NAIL
8 - 16d LAP SPLICE
11. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE 3 - 8d TOENAIL
12. RIM JOIST TO TOP PLATE 8d @ 6" O.C. TOENAIL
13. TOP PLATES, LAPS AND INTERSECTIONS 2 - 16d FACE NAIL
14. CONTINUOUS HEADER, TWO PIECES 16d 16" O.C. ALONG EDGE
15. CEILING JOISTS TO PLATE 3 - 8d TOENAIL
16. CONTINUOUS HEADER TO STUD 4 - 8d TOENAIL
17. CEILING JOISTS, LAPS OVER PARTITIONS (SEE TABLE 2308.10.4.1) 3 - 16d FACE NAIL
18. CEILING JOISTS TO PARALLEL RAFTERS (SEE TABLE 2308.10.4.1) 3 - 16d FACE NAIL
19. RAFTER TO PLATE (SEE TABLE 2308.10.4.1) 3 - 8d TOENAIL
20. 1" DIAGONAL BRACE TO EACH STUD AND PLATE 2 - 8d FACE NAIL
21. 1" X 8" SHEATHING TO EACH BEARING 3 - 8d FACE NAIL
22. WIDER THAN 1" X 8" SHEATHING TO EACH BEARING 3 - 8d FACE NAIL
23. BUILT-UP CORNER STUD 16d @ 24" O.C.
24. BUILT-UP GIRDER AND BEAMS
20d @ 32" O.C. FACE NAIL AT TOP & BOTTOM
STAGGERED ON OPPOSITE SIDES
2 - 20d FACE NAIL AT ENDS AND AT EACH
SPLICE
25. 2" PLANKS 16d AT EACH BEARING
26. COLLAR TIE TO RAFTER 3 - 10d FACE NAIL
27. JACK RAFTER TO HIP
3 - 10d TOENAIL
2 - 16d FACE NAIL
28. ROOF RAFTER TO 2-BY RIDGE BEAM
2 - 16d TOENAIL
2 - 16d FACE NAIL
29. JOIST TO BAND JOIST 3 - 16d FACE NAIL
30. LEDGER STRIP 3 - 16d FACE NAIL @ EACH JOIST
31. WOOD STRUCTURAL PANELS AND PARTICLEBOARD (2)
6d (3, 12)
SUBFLOOR AND WALL SHEATHING (TO FRAMING)
1/2" AND LESS
8d (4) OR 6d (5)19/32" TO 3/4"
8d (3)7/8" TO 1"
10d (4) OR 8d (5)1 1/8" TO 1 1/4"
6d (5)
SINGLE FLOOR (COMBINATION SUBFLOOR-UNDERLAYMENT TO
FRAMING
3/4" AND LESS
8d (5)
10d (4) OR 8d (5)
7/8" TO 1"
1 1/8" TO 1 1/4"
6d (6)
8d (6)
32. PANEL SIDING (TO FRAMING)
1/2" OR LESS
5/8"
6d
8d
33. FIBERBOARD SHEATHING (7)
1/2"
25/32"
4d (10)
6d (11)
34. INTERIOR PANELING
1/4"
3/8"
NO. 11 GAGE ROOFING NAIL (8)
NO. 11 GAGE ROOFING NAIL (8)
(1) COMMON OR BOX NAILS ARE PERMITTED TO BE USED EXCEPT WHERE OTHERWISE STATED.
(2) NAILS SPACED 6 INCHES ON CENTER AT EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES AT SUPPORTS WHERE SPANS ARE 48 INCHES OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS REFER TO IBC 2012 SECTION 2305. NAILS FOR WALL SHEATHING ARE PERMITTED TO BE COMMON, BOX OR CASING.
(2) STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16 INCH.
(3) COMMON OR DEFORMED SHANK
(4) COMMON
(5) DEFORMED SHANK
(6) CORROSION-RESISTANT SIDING OR CASING NAIL
(7) FASTENERS SPACED 3 INCHES ON CENTER AT EXTERIOR EDGES AND 6 INCHES ON CENTER AT INTERMEDIATE SUPPORTS, WHEN USED AS STRUCTURAL SHEATHING. SPACING SHALL BE 6 INCHES ON CENTER ON THE EDGES AND 12 INCHES ON CENTER AT INTERMEDIATE
SUPPORTS FOR NONSTRUCTURAL APPLICATIONS.
(8) CORROSION-RESISTANT ROOFING NAILS WITH 7/16" DIAMETER HEAD AND 1 1/2" LENGTH FOR 1/2" SHEATHING AND 1 3/4" LENGTH FOR
25/32" SHEATHING
(9) CORROSION-RESISTANT STAPLES WITH 7/16" CROWN OR 1" CROWN AND 1 1/4" LENGTH FOR 1/2" SHEATHING AND 1 1/2" LENGTH OR 25/32" SHEATHING. PANEL SUPPORTS AT 16 INCHES (20 INCHES IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS
OTHERWISE MARKED).
(10) CASING (1 1/2" X 0.080") OR FINISH (1 1/2" X 0.072") NAILS SPACED 6 INCHES ON PANEL EDGES, 12 INCHES AT INTERMEDIATE SUPPORTS.
(11) PANEL SUPPORTS AT 24 INCHES. CASING OR FINISH NAILS SPACED 6" ON PANEL EDGES, 12" AT INTERMEDIATE SUPPORTS.
(12) FOR ROOF SHEATHING APPLICATIONS, 8d NAILS ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS
(13) STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16".
(14) FASTENERS SPACED 4" ON CENTER AT EDGES, 8" AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND WALL SHEATHING AND 3" ON
CENTER AT EDGES, 6" AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING.
(15) FASTENERS SPACED 4" ON CENTER AT EDGES, 8" AT INTERMEDIATE SUPPORTS
8" 8"
1/
2"
1 1/2"
1 1/2"
NOTES:
1. ADJACENT NAILS ARE DRIVEN FROM
OPPOSITE SIDES OF THE COLUMN.
2. BUILT-UP COLUMN NAIL SPACING SHOWN IS
AS REQUIRED BY NDS 2012 CHAPTER 15.
6" 6"
6"
1/ 2"
1"
1"
BUILT-UP COLUMN
WITH (2) 2X4
BUILT-UP COLUMN
WITH (4) 2X4
60D COMMON NAIL, TYP
10D COMMON NAIL,
TYP
8" 8"
1/
2"
1 1/2"
1 1/2"
BUILT-UP COLUMN
WITH (2) 2X6
10D COMMON NAIL,
TYP
1"
1 1/2"
1 1/2"1 1/2"
1 1/2"
1" 1 1/2"
NAIL ON
OPPOSITE
SIDE, TYP
NAIL ON SIDE
SHOWN, TYP
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
A s in di ca te d
2/ 7/
2 0
:3
3 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-002
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
FA
S T
EN
IN
G S
C H
ED
U
LE
A
N D
O V E
R
EX
C A
VA
T I O
N
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 0 0
2-
NOTES:
1. THE FASTENING SCHEDULE ON THIS SHEET SHOWS MINIMUM REQUIREMENTS UNLESS NOTED
OTHERWISE. SEE DETAILS ON OTHER STRUCTURAL SHEETS FOR ADDITIONAL NAILING REQUIREMENTS.
3" = 1'-0"S-002
1 BUILT-UP COLUMN NAILING DETAIL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
3 3
1 1
3 333
3 3
3 3
3 3
2 2
2 2
TY
P
6'
0"
TYP
6' - 0"
TYP6'
- 0
ROOF CANOPY IS
OVERHANG ZONE 3
COMPONENTS & CLADDING
WIND ROOF UPLIFT PRESSURE SCHEDULE
LOCATION
TRIBUTARY AREAS
10 SF 20 SF 50 SF 100 SF
ZONE 1
ZONE 2
ZONE 3
OVERHANG
ZONE 2
OVERHANG
ZONE 3
-29.21 +18.39
-50.85 +18.39
-75.20 +18.39
-64.38 +18.39
-104.95 +18.39
-28.54 +17.04
-46.80 +17.04
-69.79 +17.04
-64.38 +17.04
-95.49 +17.04
-27.19 +14.34
-41.39 +14.34
-64.38 +14.34
-64.38 +14.34
-81.96 +14.34
-26.51 +12.98
-37.33 +12.98
-58.97 +12.98
-64.38 +12.98
-72.49 +12.98
NOTES:
1. ALL WIND LOADS ARE UNFACTORED LOADS.
COMPONENTS & CLADDING WALL WIND PRESSURE SCHEDULE
LOCATION
TRIBUTARY AREAS
10 SF 20 SF 50 SF 100 SF
ZONE 4
ZONE 5
-34.62 +31.92
-42.74 +31.92
-33.27 +30.57
-39.76 +30.57
-30.57 +28.40
-35.98 +28.40
-29.89 +27.05
-33.27 +27.05
200 SF
-28.54 +25.70
-30.30 +25.70
500 SF
-26.51 +23.80
-26.51 +23.80
NOTES:
1. ALL WIND LOADS ARE UNFACTORED LOADS.TYP
6' - 0"
5 5 5
5 54
(TYP)
6' - 0"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
A s in di ca te d
2/ 7/
2 0
:3
3 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
K.
R
EP
AS
KE
Y
W .B
O
EC
K
A F7
-3
-0
S-003
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
C O
M P O
N
EN
TS
C
LA
D D
IN
G W
IN
D
L O
A D
D
IA
G
RA
M S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 0 0
3-
1" = 10'-0"S-003
1 ROOF WIND UPLIFT ZONES
PLAN NORTH
0 1' 2'
2' 4'1'0
1" = 10'-0"S-003
3 EAST & WEST WALLS WIND PRESSURE ZONES
1" = 10'-0"S-003
2 SOUTH WALL WIND PRESSURE ZONES
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
EB C D
20 PSF
EB C D
14.8 PSF
6 PSF 6 PSF
NOTE:
1. SEE NOTE 3
EB C D
37.8 PSF 37.8 PSF
NOTE:
1. SEE NOTES 4 AND 5.
EB C D
CASE A: 22.4 PSF
CASE B: 31.1 PSF
CASE A: 20.6 PSF
CASE B: 17.7 PSF
EC D
20 PSF
EC D
14.8 PSF
6 PSF
6 PSF NOTE:
1. SEE NOTE 3.
EC D
37.8 PSF
37.8 PSF
NOTE:
1. SEE NOTES 4 AND 5.
EC D
CASE A: 20.6 PSF
CASE B: 17.7 PSF
CASE A: 22.4 PSF
CASE B: 31.1 PSF
4 5
6 PSF6 PSF
NOTE:
1. SEE NOTE 3.
4 5
37.8 PSF37.8 PSF
NOTE:
1. SEE NOTES 4 AND 5.
4 5
31.1 PSF31.1 PSF
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
A s in di ca te d
2/ 7/
2 0
:3
3 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-004
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
R O
O F
TR
U
SS
L
O
AD
I N G
D I A
G R
A M
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 0 0
4-
3/16" = 1'-0"S-004
1 TRUSS RT1 LIVE LOAD (L)
3/16" = 1'-0"S-004
2 TRUSS RT1 DEAD LOAD (D)
3/16" = 1'-0"S-004
3 TRUSS RT1 SNOW LOAD (S)
3/16" = 1'-0"S-004
4 TRUSS RT1 WIND LOAD (W)
3/16" = 1'-0"S-004
5 TRUSS RT2 LIVE LOAD (L)
3/16" = 1'-0"S-004
6 TRUSS RT2 DEAD LOAD (D)
3/16" = 1'-0"S-004
7 TRUSS RT2 SNOW LOAD (S)
3/16" = 1'-0"S-004
8 TRUSS RT2 WIND LOAD (W)
1/4" = 1'-0"S-004
9 TRUSS RT3 DEAD LOAD (D)
1/4" = 1'-0"S-004
10 TRUSS RT3 SNOW LOAD (S)
1/4" = 1'-0"S-004
11 TRUSS RT3 WIND LOAD (W)
NOTES:
1. DETAILS ON THIS SHEET ARE INTENDED ONLY TO INDICATE MINIMUM UNFACTORED LOADS TO BE USED FOR TRUSS DESIGN. SEE OTHER SHEETS FOR ROOF SLOPES, OVERHANGS, CANTILEVERS, BEARING
WALL LOCATIONS AND BEARING WALL LOCATIONS.
2. TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING LRFD LOAD COMBINATIONS AND OTHER
LOAD COMBINATIONS IN ASCE 7-10:
1.4D 1.2D+1.6L+0.5S 1.2D+1.6S+0.5L 0.9D+W
3. DEAD LOAD SHOWN INCLUDES ROOFING AND ATTIC LOADS. WEIGHT OF TRUSS MEMBERS ARE NOT SHOWN.
TRUSS MANUFACTURER SHALL INCLUDE THE DEAD LOAD WEIGHT OF TRUSS MEMBERS USED IN THEIR
DESIGN IN LOAD DETERMINATIONS.
4. TRUSS MANUFACTURER SHALL INCLUDE THE FOLLOWING PARTIAL SNOW LOADING SCENARIOS
PER ASCE 7-10:
A. CASE 1: FULL BALANCED SNOW LOAD ON EITHER EXTERIOR SPAN AND HALF THE BALANCED
SNOW LOAD ON ALL OTHER SPANS.
B. CASE 2: HALF THE BALANCED SNOW LOAD ON EITHER EXTERIOR SPAN AND FULL BALANCED
SNOW LOAD ON ALL OTHER SPANS.
C. CASE 3: ALL POSSIBLE COMBINATIONS OF FULL BALANCED SNOW LOAD ON ANY TWO
ADJACENT SPANS AND HALF THE BALANCED SNOW LOAD ON ALL OTHER SPANS.
PARTIAL LOAD PROVISIONS NEED NOT BE APPLIED TO STRUCTURAL MEMBERS THAT SPAN
PERPENDICULAR TO THE RIDGELINE.
5. TRUSS MANUFACTURER SHALL INCLUDE THE UNBALANCED SNOW LOADING SCENARIOS
DESCRIBED IN ASCE 7-10 PARAGRAPH 7.6.
0 4' 8' 12'
4' 8'0 2'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
B
A
C
D
4 5
A.5
S-301
S-3011
S-301
5" 5"5"
5"
5" 5" 5" 5"
4" SLAB W/ #3@12" E.W. OR W.W.F.
REINFORCEMENT W/ 0.1 IN²/FT EA
WAY W/ MAX 12" SPACING E.W. AT
SLAB MID-DEPTH, TYP
S-301
SIM
S-301
S-301
STRUCTURAL STOOP SLAB
LEGEND:
S-301
SIM
S-302
11' - 8" 17' - 0" 11' - 2" 17' - 4" 11' - 2" 17' - 0" 11' - 8"
1'
0" 1'
0"
5'
2'
0"
6'
4"
4' - 0"
5'
0"
6'
4"
4' - 0"
7' - 4"
4'
0"
7" 7"
1' - 9" 8' - 3"
8" FOUNDATION WALL
4" STRUCTURAL SLAB
10" STRUCTURAL SLAB
12" STRUCTURAL SLAB
10" STRUCTURAL SLAB (2" DEPRESSION)
4" STRUCTURAL SLAB (2" DEPRESSION)
NOTE:
1. 2" DEPRESSION AT ENTRANCES SHALL HAVE TOP OF SLAB AT ELEVATION 99'-10".
2. PROVIDE A TRANSITION SLOPE OF 1V:3H IN TRANSITION AREAS BETWEEN DIFFERENT SLAB
THICKNESS. THE THICKER SLAB SHALL FILL THE ENTIRE EXTENTS SHOWN.
38' - 1 5/8" 3' - 0" 13' - 7 3/4" 3' - 0" 38' - 1 5/8"
/2
/2
3" 3"
3" 3"
3'
8" 5'
3'
8"
1"
10' - 7 1/2" 12' - 6" 12' - 6" 12' - 4" 12' - 4" 12' - 6" 12' - 6" 10' - 7 1/2"
CONSTRUCTION OR CONTROL JOINT
S-301
SIM
S-301
2' - 0"
8" STEM
WALL, TYP
(2) 3'-0" #4 @
REENTRANT CORNERS
@ SLAB MID-DEPTH, TYP
(2) 1.5"X5.5"
BUILT-UP
WOOD COL, TYP
(2) 1.5"X5.5"
BUILT-UP WOOD
COL, TYP
(2) 1.5"X5.5"
BUILT-UP WOOD
COL, TYP
(2) 1.5"X5.5"
BUILT-UP
WOOD COL, TYP
5' - 3 3/4" 5' - 3 3/4"5' - 3 3/4" 5' - 3 3/4"
1/
4"
1' - 8 1/2"
1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2"
1/
2"
1/
2"
1/ 2"
1/
2"
CONTROL JOINT, TYP
EXTERIOR EQUIPMENT
PAD (CU-1). SEE
MECHANICAL AND 10/S-302.
INTERIOR
EQUIPMENT
PADS. SEE
MECHANICAL
AND 9/S-302.
AHU-1
GF-1 &
ET-1
GWH-1
CU-1
PROVIDE 6"
EQUIPMENT
PAD FOR
AHU-1
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/1
6"
'-0
2/ 7/
2 0
:3
4 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-100
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
F O
UN
D A
TI
O N
A N
D
SL
AB
P
LA
N
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 1 0
0-
3/16" = 1'-0"S-100
1 FOUNDATION PLAN
PLAN NORTH
0 4' 8' 12'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
TRUSS BEARING
EL: 109'-4"
TRUSS BEARING
EL: 109'-4"
E
F
B
A
C
D
4 5
A.5
1'
0" 1'
0"
5'
2'
0"
R T1
R T1
R T1
R T1
R T1
R T1
R T1
R T1
R T2
R T2
R T2
R T2
R T2
R T2
R T1
R T1
R T1
R T1
R T1
R T1
R T1
R T1
R T1
RT3
RT3
RT3
RT3
RT3
5.5"X13.5" GLULAM BEAM
5.5"X11.5" GLULAM BEAM
5.5"X13.5" GLULAM BEAM
5.5"X11.5" GLULAM BEAM
(EL: 109'-4")
(EL: 109'-4")
5.5"x11.5" GLULAM BEAM
(EL: 109'-4")
5.5"X11.5" GLULAM BEAM
(EL: 109'-4")
(EL: 109'-4")
(EL: 109'-4")
4' - 0" TYP
8'
0" T
YP
ATTIC DIAPHRAGM SHEATHING
AND BLOCKING. SEE 1/S-304.
PROVIDE 1.5"X3.5"
BLOCKING AT 24" O.C., TYP
S-303
S-303
S-303
S-303
VALLEY, TYP
11' - 8" 17' - 0" 11' - 2" 17' - 4" 11' - 2" 17' - 0" 11' - 8"
TR
U
SS
B
EA
R
IN
G
E L .
: 1
-6
SE
E
S-
FO
R R
T3 T
R U
SS
P
R O
FI
LE
S
4.5"X10.5" GLULAM BEAM
S-303
S-303
S-303
4'-3"
SEE S-201 FOR RT1 TRUSS PROFILE
(9) SPACES @ 4'-0" O.C.
SEE S-201 FOR RT2 TRUSS PROFILE
(5) EQ SPACES)
SEE S-201 FOR RT1 TRUSS PROFILE
(9) SPACES @ 4'-0" O.C. 4'-3"
16'-6"
RELIEF AIR DUCT THROUGH
ROOF, SEE MECH. PROVIDE
BLOCKING AS NEEDED
ATTIC ACCESS HATCH
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/1
6"
'-0
2/ 7/
2 0
:3
4 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
K.
R
EP
AS
KE
Y
W .B
O
EC
K
A F7
-3
-0
S-110
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
R O
O F
FR
A
M
IN
G P
LA
N
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 1 1
0-
3/16" = 1'-0"S-110
1 ROOF FRAMING PLAN
TRUSS MANUFACTURER NOTES:
1. ALL PREFABRICATED TRUSSES SHALL BE FABRICATED BY AN INTERNATIONAL CODE COUNCIL (ICC)
APPROVED TRUSS MANUFACTURER.
2. THE CONTRACTOR SHALL SUBMIT FOR APPROVAL DESIGN CALCULATIONS FOR ALL TRUSSES. THE CALCULATIONS SHALL SHOW THE TYPE OF TRUSS, COMPLETE TRUSS PROFILE, DIAGRAMS OF ALL
LOADS USED IN THE DESIGN OF THE TRUSS, AND LOCATIONS OF BEARING WALLS. PROVIDE
COMPLETE INFORMATION ABOUT ANY COMPUTER SOFTWARE USED IN THE CALCULATIONS.
3. ALL CALCULATIONS AND SHOP DRAWINGS SHALL BE SIGNED BY A STRUCTURAL ENGINEER LICENSED
WITH A PE IN THE STATE OF NORTH DAKOTA.
4. TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE FOLLOWING FOR ALL LOADS IMPOSED
INCLUDING LATERAL LOADS AND MECHANICAL EQUIPMENT LOADS. :
AITC TIMBER CONSTRUCTION MANUAL (TCM), 6TH EDITION, 2012
IBC 2012
ANY APPLICABLE LOCAL APPROVED CODES AND ORDINANCES
TRUSS PLATE INSTITUTE (TPI) MOST CURRENT STANDARDS
5. TRUSS FABRICATOR SHALL REVIEW ALL ARCHITECTURAL DRAWINGS AND MEET ARCHITECTURAL
PROFILES AS INDICATED.
6. ERECTION DRAWINGS SHALL INDICATE ALL REQUIRED PERMANENT BRACING FOR TRUSS MEMBERS AND ALL REQUIRED TEMPORARY BRACING TO ADEQUATELY BRACE ALL TRUSSES DURING CONSTRUCTION.
7. TIE DOWNS SHALL BE PROVIDED IN ACCORDANCE WITH THE TRUSS MANUFACTURER
RECOMMENDATIONS FOR FASTENING TRUSSES TO ALL LOAD BEARING WALLS.
8. TRUSS CONNECTIONS TO SIPS BY SIP MANUFACTURER. COORDINATE CONNECTIONS WITH TRUSS
MANUFACTURER.
PLAN NORTH
0 4' 8' 12'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
(2) 1.5"X5.5" BUILT-
UP WOOD COL, TYP
(2) 1.5"X5.5" BUILT-
UP WOOD COL, TYP
(2) 1.5"X5.5" BUILT-
UP WOOD COL, TYP
(2) 1.5"X5.5" BUILT-
UP WOOD COL, TYP
2 (1.5"X5.5") BUILT-UP
WOOD COL, TYP3/
S-
IN
TE
R
IO
R S
IP
S
H
EA
R W
AL
L
EX
TE
N T
SI
M
. 3 /S
-2
IN
TE
R
IO
R S
IP
S
H
EA
R W
AL
L
EX
TE
N T
1/S-210
INTERIOR CORRIDOR SHEAR WALL EXTENT
SIM. 1/S-210
INTERIOR CORRIDOR SHEAR WALL EXTENT
2 (1.5"X5.5") BUILT-
UP WOOD COL, TYP
S-305
S-305
2/S-211
SOUTH SIP SHEAR WALL EXTENT
1/S-211
NORTH SIP SHEAR WALL EXTENT
GLULAM DRAG STRUT/BEAM
BEARING TRUSSES
2/ S-
W E
S T
S
IP
S H
E A
R W
A
LL
E X
TE
N
T
SI
M
. 2 -S
E A
ST
S
IP
S
H E
AR
W
AL
L
E
XT
EN
T
GLULAM DRAG STRUT/BEAM
BEARING TRUSSES
GLULAM DRAG STRUT/BEAM
BEARING TRUSSES
GLULAM DRAG STRUT/BEAM
BEARING TRUSSES
GLULAM DRAG STRUT/BEAM
BEARING TRUSSES
TYP
TYP
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/1
6"
'-0
2/ 7/
2 0
:3
4 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-120
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
S H
EA
R A
ND
L
O A
D
BE
A
RI
NG
W
A
LL
P
LA
N
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 1 2
0-
NOTES:
1. SIP PANELS BY SIP MANUFACTURER.
2. COORDINATE VERTICAL LOADS WITH TRUSS MANUFACTURER.
3. INTERIOR WALLS SHALL BE DESIGNED FOR A MINIMUM LATERAL LOAD OF 5 PSF.
4. SEE SHEET S-210 AND S-211 FOR VERTICAL CHORD LOCATION AND LOADS.
5. TRUSS AND SIP MANUFACTURER SHALL COORDINATE DESIGN OF TRUSS BEARING ON SIP CONNECTIONS.
6. SIP MANUFACTURER SHALL PROVIDE INTERIOR FRAMING IN SIP PANELS AS REQUIRED BY IBC 2012 AND NDS 2012
IN ADDITION TO INTERIOR FRAMING SHOWN.
PLAN NORTH
0 4' 8' 12'
3/16" = 1'-0"S-120
1 SHEAR AND LOAD BEARING WALL PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
TRUSS BEARING
109'-4"
25' - 7" 5' - 10" 25' - 7"
ATTIC WALKWAY
ROOF SLOPE ROOF SLOPE
NOTES:
1. WOOD TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR THE TRUSS CONFIGURATION WHILE ENSURING THE
MINIMUM ATTIC WALKWAY DIMENSIONS ARE MET.
2. TRUSS AND SIP MANUFACTURER SHALL COORDINATE DESIGN OF TRUSS BEARING ON SIP CONNECTIONS.
SIP PANEL,
SEE ARCH DWGS
SIP PANEL,
SEE ARCH DWGS
INT. LOAD BEARING WALLS,
SEE ARCH DWGS
6'
6" M
IN
MIN 5'-0" CLR12
/2
TRUSSES EXTEND AT
GABLES. SEE 6/S-303
TRUSSES EXTEND AT
GABLES. SEE 6/S-303
EC D
TRUSS BEARING
109'-4"
3' - 8 5/8" 5' - 10" 25' - 7"
ATTIC
WALKWAY
ROOF
SLOPE
ROOF
SLOPE
SIP PANEL,
SEE ARCH DWGS
INT. LOAD BEARING
WALLS, SEE ARCH DWGS
NOTES:
1. WOOD TRUSS MANUFACTURER SHALL BE RESPONSIBLE FOR THE TRUSS CONFIGURATION WHILE ENSURING THE
MINIMUM ATTIC WALKWAY DIMENSIONS ARE MET.
2. TRUSS AND SIP MANUFACTURER SHALL COORDINATE DESIGN OF TRUSS BEARING ON SIP CONNECTIONS.
6'
6" M
IN
/2
MIN 5'-0" CLR
INT. WALL (NOT
LOAD BEARING)
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/8
'-0
2/ 7/
2 0
:3
5 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
K.
R
EP
AS
KE
Y
W .B
O
EC
K
A F7
-3
-0
S-201
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
R O
O F
TR
U
SS
P
R O
FI
L E
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 2 0
1-
3/8" = 1'-0"S-201
1 ROOF TRUSS RT1 PROFILE
3/8" = 1'-0"S-201
2 ROOF TRUSS RT2 PROFILE
0 2' 4' 6'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
4 5
ENTRY TRUSS BRG
115'-6"
8' - 8" 8' - 8"
SIPS TYP EA. SIDE,
SEE ARCH DWGS
NOTES:
1. TRUSS AND SIP MANUFACTURER SHALL COORDINATE DESIGN OF TRUSS BEARING ON SIP CONNECTIONS.
2. CONNECTIONS FOR ROOF TRUSS RT3 ELEMENTS SHALL BE WITH BLACK COATED HEX NUTS AND BOLTS WITH BLACK STEEL PLATES.
3. TRUSS MANUFACTURER SHALL PROVIDE CONNECTION TO GLULAM BEAM FOR BEARING AND UPLIFT FORCES. SIP MANUFACTURER SHALL PROVIDE CONNECTION TO SIP WALL. PROVIDE MINIMUM LRFD BEARING LOAD OF 3.0 KIPS AND MINIMUM LRFD UPLIFT LOAD OF 1.3 KIPS. COORDINATE WITH TRUSS MANUFACTURER FOR EXACT LOADS. CONNECTIONS SHALL BE MADE WITH BLACK COATED HEX NUTS
AND BOLTS WITH BLACK STEEL PLATES.
4.5"X10.5"
GLULAM BEAM,
SEE NOTE 3
BOTTOM CHORD SHALL BE MINIMUM OF 3.5"X7.5", TYP
TOP CHORDS AND WEBS SHALL
BE MINIMUM OF 3.5"X5.5", TYP
S-303
Sim
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/4
'-0
2/ 7/
2 0
:3
5 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
K.
R
EP
AS
KE
Y
W .B
O
EC
K
A F7
-3
-0
S-202
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
R O
O F
TR
U
SS
P
R O
FI
L E
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 2 0
2-
0 1' 2' 3'
3/4" = 1'-0"S-202
1 ROOF TRUSS RT3 PROFILE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
X BRACING
SHALL CROSS 2
TRUSSES, TYP
36'-0" - RT1 TRUSSES
GAP
16'-6" - RT2 TRUSSES
GAP
36'-0" - RT1 TRUSSES
TRUSS WITH X-BRACING (TYP)
TRUSS WITHOUT
X- BRACING (TYP)
SIP PANEL LOAD
BEARING WALL (TYP)
BRACE ALL CHORDS
ON TRUSSES
WHERE SHOWN, TYP
PROVIDE ROOM TO WALKWAY
FROM ATTIC ACCESS HATCH
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/8
'-0
2/ 7/
2 0
:3
5 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-203
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
TR
U
S S B
R A
CI
NG
D
ET
A
IL
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 2 0
3-
NOTES:
1. TEMPORARY AND PERMANENT TRUSS BRACING SHALL BE IN ACCORDANCE WITH BCSI 2013 (BUILDING COMPONENT SAFETY INFORMATION GUIDE TO GOOD PRACTICE FOR HANDLING, INSTALLING, RESTRAINING & BRACING OF METAL PLATE CONNECTED WOOD TRUSSES).
2. TEMPORARY TRUSS BRACING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ANY DAMAGES CAUSED BY INADEQUATE TEMPORARY
TRUSS BRACING SHALL BE AT THE COST OF THE CONTRACTOR.
3. PERMANENT LATERAL BRACING AND X-BRACING SHALL BE DESIGNED AND SUBMITTED BY THE TRUSS MANUFACTURER FOR APPROVAL BY USACE. BRACING SHALL BE PROVIDED IN THE DESIGN ANALYSIS AND TRUSS PLACEMENT PLAN.
4. TEMPORARY BOTTOM CHORD BRACING SHALL BE USED FOR TEMPORARY BRACING AND SHALL BE REMOVED ONCE THE BLOCKING AND SHEATHING IN THE ATTIC FLOOR HAVE BEEN CONSTRUCTED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS.
5. X-BRACING SHALL BE PROVIDED AT LOCATIONS OF PERMANENT LATERAL BRACING AS SPECIFIED BY THE TRUSS MANUFACTURER.
6. X-BRACING SHOWN ARE RECOMMENDED LOCATIONS TO BE USED BY THE TRUSS MANUFACTURER. FINAL LOCATIONS SHALL BE PROVIDED BY
THE TRUSS MANUFACTURER.
PLAN NORTH
S-203
1 TYPICAL PERMANENT WEB MEMBER X-BRACING PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
NOT TO SCALE
NOTES:
1. EAST AND WEST WALLS ARE SIMILAR
2. HORIZONTAL CHORDS AND STRUTS SHALL HAVE A CAPACITY OF 0.2 KIPS IN COMPRESSION AND TENSION FOR UNFACTORED WIND LOADS.
3. VERTICAL CHORDS SHALL HAVE A CAPACITY OF 0.6 KIPS IN UNFACTORED COMPRESSION AND TENSION IN ADDITION TO LOADS DUE TO GRAVITY AND WIND UPLIFT ON THE ROOF.
SECTIONS OF SIP PANEL
ACTING AS SHEAR WALL, TYP
PROVIDE VERTICAL CHORDS
WHERE SHOWN, TYP
UNFACTORED WIND ATTIC
DIAPHRAGM SHEAR LOAD:
100 POUNDS PER FOOT
TOTAL UNFACTORED
WALL SHEAR LOAD
FROM WIND: 3.0 KIPS
HORIZONTAL
CHORD/STRUT, TYP
ANCHOR BRACKET
WITH CAPACITY OF 0.6
KIPS UNFACTORED
LOAD FOR UPLIFT, TYP
EB C D
NOTE:
1. BOTH INTERIOR SIP WALLS ARE SIMILAR.
2. HORIZONTAL CHORDS AND STRUTS SHALL HAVE A CAPACITY OF 0.3 KIPS IN COMPRESSION AND TENSION FOR UNFACTORED WIND LOAD.
3. VERTICAL CHORDS SHALL HAVE A CAPACITY OF 1.0 KIPS IN UNFACTORED COMPRESSION AND TENSION IN ADDITION TO LOADS DUE TO GRAVITY AND WIND UPLIFT ON THE ROOF.
PROVIDE VERTICAL CHORDS
WHERE SHOWN, TYP
SECTIONS OF SIP PANEL
ACTING AS SHEAR WALL, TYP
UNFACTORED WIND ATTIC
DIAPHRAGM SHEAR LOAD:
100 POUNDS PER FOOT
TOTAL UNFACTORED
WALL SHEAR LOAD
FROM WIND: 5.5 KIPS
MIN LRFD TRUSS LOAD = 1.3 KIPS PER TRUSS
COORDINATE WITH TRUSS MANUFACTURER FOR EXACT LOAD
HORIZONTAL
CHORD/STRUT, TYP
ANCHOR BRACKET
WITH CAPACITY OF 1.0
KIPS UNFACTORED
LOAD FOR UPLIFT, TYP
SEE SHEET S-305 FOR
WALL CONNECTION
FINISHED FLOOR
100'-0"
8632 4 5
TRUSS BEARING
109'-4"
(4) 2X4 STUDS AT
TRUSS BEARING, TYP
(1) 2X4 STUD
INTERMEDIATE TO
TRUSS BEARING
5.5"X13.5" GLU-LAM BEAM
(2) 2X6 BUILT-UP
COLUMN, SEE S-002
(2) 2X4 HEADERS ON
EDGE. SEE NOTE 2. TRUSSES, TYPATTIC FLOOR
DIAPHRAGM
12' - 6 1/2" 3' - 4" 12' - 6 1/2"3' - 4"8' - 7"3' - 4"12' - 4"16' - 9"12' - 4"3' - 4"8' - 7"
PROVIDE STRUCTURAL SHEATHING ON
CORRIDOR SIDE WITH 6D NAILS SPACED AT 6
INCHES AT PANEL EDGES. SEE ARCHITECTURAL.
ANCHOR BRACKET
WITH CAPACITY OF 1.0
KIPS UNFACTORED
LOAD FOR UPLIFT, TYP
NOTE:
1. SHEAR WALL ON OPPOSITE SIDE OF CORRIDOR IS SIMILAR.
2. HEADER SIZES ARE BASED ON TRUSSES NOT LINING UP ON TOP OF DOORS AS
SHOWN. IF A TRUSS DOES LINE UP ON TOP OF A DOOR PLEASE ADVISE THE COR.
3. VERIFY AND ADJUST DIMENSIONS BASED ON ACTUAL DOOR SIZES.
(2) 2X4 STUDS
@ END OF WALL
2X4 JACK STUD, TYP
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/1
6"
'-0
2/ 7/
2 0
:3
6 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-210
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
SH
E A
R W
A
LL
S
EC
TI
O
N S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 2 1
0-
3/16" = 1'-0"S-210
2 WEST SIP SHEAR WALL
3/16" = 1'-0"S-210
3 INTERIOR SIP SHEAR WALL
0 4' 8' 12'
3/16" = 1'-0"S-210
1 INTERIOR CORRIDOR SHEAR WALL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
8 6 3 2457 1
NOTE:
1. HORIZONTAL CHORDS AND STRUTS SHALL HAVE A CAPACITY OF 0.8 KIPS IN COMPRESSION AND TENSION FOR UNFACTORED WIND LOADS.
2. VERTICAL CHORDS SHALL HAVE A CAPACITY OF 1.9 KIPS IN UNFCATORED COMPRESSION AND TENSION IN ADDITION TO LOADS DUE TO GRAVITY AND WIND UPLIFT ON THE ROOF.
PROVIDE VERTICAL CHORDS
WHERE SHOWN, TYP
SECTIONS OF SIP PANEL
ACTING AS SHEAR WALL, TYP
UNFACTORED WIND ATTIC
DIAPHRAGM SHEAR LOAD:
100 POUNDS PER FOOT
WINDWARD UNFACTORED
WALL SHEAR LOAD FROM
WIND: 1.7 KIPS
UNFACTORED WIND ATTIC DIAPHRAGM
SHEAR LOAD: 100 POUNDS PER FOOT
MIN LRFD TRUSS LOAD = 4.3 KIPS PER TRUSS
MIN LRFD TRUSS UPLIFT LOAD = 2.0 KIPS PER TRUSS
COORDINATE WITH TRUSS MANUFACTURER FOR EXACT LOAD
HORIZONTAL
CHORD/STRUT, TYP
GLULAM BEAM SUPPORTING
TRUSSES TO TRANSFER STRUT
LOAD. SEE SHEET S110, TYP
ANCHOR BRACKET
WITH CAPACITY OF 1.9
KIPS UNFACTORED
LOAD FOR UPLIFT, TYP
TRUSSES BEAR ON GLULAM BEAM TRUSSES BEAR ON GLULAM BEAM
23'-0 1/4"
7'-0 1/4"
8632 4 5 71
NOTE:
1. HORIZONTAL CHORDS AND STRUTS SHALL HAVE A CAPACITY OF 0.7 KIPS IN COMPRESSION AND TENSION FOR UNFACTORED WIND LOADS.
2. VERTICAL CHORDS SHALL HAVE A CAPACITY OF 0.7 KIPS IN UNFACTORED COMPRESSION AND TENSION IN ADDITION TO LOADS DUE TO GRAVITY AND WIND UPLIFT ON THE ROOF.
PROVIDE VERTICAL CHORDS
WHERE SHOWN, TYP SECTIONS OF SIP PANEL
ACTING AS SHEAR WALL, TYP
UNFACTORED WIND ATTIC
DIAPHRAGM SHEAR LOAD:
100 POUNDS PER FOOT
TOTAL UNFACTORED
WALL SHEAR LOAD FROM
WIND: 3.0 KIPS
MIN LRFD TRUSS LOAD = 4.3 KIPS PER TRUSS
MIN LRFD TRUSS UPLIFT LOAD = 2.0 KIPS PER TRUSS
COORDINATE WITH TRUSS MANUFACTURER FOR EXACT LOAD
ANCHOR BRACKET
WITH CAPACITY OF 0.7
KIPS UNFACTORED
LOAD FOR UPLIFT, TYP
HORIZONTAL
CHORD/STRUT, TYP
GLULAM BEAM SUPPORTING
TRUSSES TO TRANSFER STRUT
LOAD. SEE SHEET S110, TYP
TRUSSES BEAR ON GLULAM BEAMTRUSSES BEAR ON GLULAM BEAM
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
/1
6"
'-0
2/ 7/
2 0
:3
6 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-211
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
SH
E A
R W
A
LL
S
EC
TI
O
N S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 2 1
1-
3/16" = 1'-0"S-211
1 NORTH SIP SHEAR WALL
3/16" = 1'-0"S-211
2 SOUTH SIP SHEAR WALL
0 4' 8' 12'
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
FINISHED FLOOR
100'-0"
3' - 0"
CONTROL JOINT
SLAB REINF,
SEE PLAN
#4 @ 12" O.C.E.W.
#3 SPLICE @ 12" O.C.
SLAB REINF, SEE PLAN
2"
1'
0"
4" CAPILLARY
BARRIER
VAPOR BARRIER
FINISHED FLOOR
100'-0"
C D
4" CAPILLARY
BARRIER
#4 @ 12" O.C.E.W.
13' - 2"
3' - 8" 5' - 10" 3' - 8"
1 V 3 H
SLAB REINF,
SEE PLAN
1 V 3 H
VAPOR BARRIER
FINISHED FLOOR
100'-0"
C D
4" CAPILLARY
BARRIER #4 @ 12" O.C.
EA WAY
1 V 3 H
1 V 3 H
CONTRACTION JOINT
SPLICE REINF W/ #3 @ 12" O.C.
3' - 8" 5' - 10" 3' - 8"
2"
VAPOR BARRIER
SUBGRADE
CONCRETE FLOOR SLAB
4"
20 MIL GEOMEMBRANE
VAPOR BARRIER
4" CAPILLARY
WATER BARRIER
FINISHED FLOOR
100'-0"
TOP OF FOOTING
95'-6"
4" CAPILLARY
WATER BARRIER
SIPS PANEL,
SEE ARCH DWGS
1/2" RIGID INSULATION
(3) #4 EQ SPACED
#4 HORIZ. @ 12" O.C.
#4 VERT. @ 10" O.C.
SLAB REINF,
SEE PLAN
2' - 0"
1'
0"
8" 8" 8"
3" C
LR
VAPOR BARRIER
#4 HOOK @ 10" O.C.,
ALTERNATE HOOK
DIRECTION
2" RIGID INSULATION
FINISHED FLOOR
100'-0"
TOP OF FOOTING
95'-6"
4" CAPILLARY
WATER BARRIER#4 @ 12" O.C.E.W.
WALL BEYOND,
SEE ARCH DWGS
1/2" RIGID
INSULATION
#4 VERT. @ 10" O.C.,
#4 HORIZ. @ 12" O.C.
2" DEPRESSION,
SEE PLAN
0.25" V
SLAB REINF,
SEE PLAN
1'-0" H
2' - 0"
8" 8" 8"
1'
0"
3" C
LR
4" @ 12" O.C.E.W.
1'
0"
UNCOMPACTED FILL
COMPACTED FILL TO
BOTTOM OF SIDEWALL
VAPOR BARRIER
#4 HOOK @ 10"
O.C., ALTERNATE
HOOK DIRECTION
6" M
IN
2" RIGID INSULATION
FINISHED FLOOR
100'-0"
TOP OF FOOTING
95'-6"
#4 VERT. @ 10" O.C.,
#4 HORIZ @ 12" O.C.
4" CAPILLARY WATER BARRIER
SLAB REINF, SEE PLAN
#4 @ 12" O.C.E.W.
1/2" RIGID INSULATION
4" SLAB, SEE PLAN
WALL BEYOND, SEE ARCH
0.25" V 1'-0" H
3" C
LR
1'
0"
8" 8" 8"
2' - 0"
2"
SEE PLAN
1'
0"
UNCOMPACTED FILL
COMPACTED FILL TO
BOTTOM OF SIDEWALL
1 V
3 HVAPOR BARRIER
#4 HOOK @ 10" O.C.,
ALTERNATE HOOK
DIRECTION
CONTRACTION
JOINT
6" M
IN
2" RIGID iNSULATION
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
A s in di ca te d
2/ 7/
2 0
:3
6 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
K.
R
EP
AS
KE
Y
W .B
O
EC
K
A F7
-3
-0
S-301
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
FO
U
N D A
TI
O
N S
E C
TI
O N
S A
N D
D
ET
A
IL
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 3 0
1-
3/4" = 1'-0"S-301
6 THICKENED SLAB - ENTRYWAY
3/4" = 1'-0"S-301
4 THICKENED SLAB - CORRIDOR
3/4" = 1'-0"S-301
5 THICKENED SLAB - CORRIDOR DEPRESSION
0 1' 2'
0 4' 8' 12'
0 1' 2' 3'
1" = 1'-0"S-301
7 TYP WATER VAPOR BARRIER DETAIL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
3/4" = 1'-0"S-301
1 TYP. FOUND. WALL SECTION
3/4" = 1'-0"S-301
2 STOOP DETAIL - CORRIDOR
3/4" = 1'-0"S-301
3 STOOP DETAIL - TYPICAL
TH
IC
KN
ES
S (T
3/8"
3/ 4"
T/
O R
/2
SAWCUT SEALANT
RESERVOIR
CENTERED ON
SLAB JOINT
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
SLAB REINF. STOP
2" FROM JOINT, TYP.
1'-3" - 3/4" DIA. SMOOTH
DOWELS @ 16" O.C.
PAINTED AND OILED PER
SPECIFICATIONS
T/
SAW CUT SHOWN IS FOR SLABS
WITH/OUT FLOOR COVERING.
FOR SLABS W/ FLOOR
COVERING TOOL 1/8" RADIUS
TH
IC
KN
ES
S (T
3/8"
3/ 4"
T/
O R
/2
SAWCUT SEALANT
RESERVOIR
CENTERED ON
SLAB JOINT W
H
IC
H
EV
ER
IS
G R
EA
TE
R
SLAB REINF
SAW CUT SHOWN IS FOR SLABS
W/OUT FLOOR COVERING. FOR
SLABS W/ FLOOR COVERING
PROVIDE HARDBOARD INSERT
OR 1/8" WIDE SAW CUT
CORNER BARS TO MATCH
HORIZONTAL BARS
SE
E
S-
SP
LI
C E
LE
N
G
TH
2'
0"
EXTRA VERTICAL BAR
CORNER BARS TO MATCH
HORIZONTAL BARS
SE
E
S-
SP
LI
C E
LE
N
G
TH
2'
0"
2' - 0"
SEE S-001
SPLICE LENGTH
FINISHED FLOOR
100'-0"
3' - 0" SQUARE
1'
4"10" DIA.
3'
0"
3" C
LR
2" C
LR
(3) #4 E.F.E.W. SPACED EVENLY
(2) #4 TIES SPACED EVENLY
(3) #4 SPACED EVENLY
BUILT-UP-COLUMN AT CENTER OF
FOUNDATION COLUMN
SLAB REINF.
SEE PLAN
#4 @ 12" O.C.
EA WAY
INTERIOR WALL, SEE ARCH
4" CAPILLARY BARRIER
VAPOR BARRIER
(2) #4 TIES
(3) VERT. #4
SPACED
EVENLY
NAILS BY SIP
MANUFACTURER
CONTINUOUS SEALANT
BY SIP MANUFACTURER
5/8" DIA. ANCHOR
BOLTS AT 22" O.C.
STEM WALL
CAPILLARY BREAK, MIN. 6
MIL POLY OR MIN. 3/4"
PRESSURE TREATED
WOOD UNDER SILL PLATE
AND BOTH FACES
PROVIDE TERMITE SHIELD
FIELD INSTALLED
TREATED BOTTOM
PLATE
SIP WALL
7" M
IN
NOTE: ANCHOR BOLTS MUST
MEET MINIMUM REQUIREMENTS
OF IBC 2012 PARAGRAPH 2308.6.
1/2" DIA. ANCHOR
BOLTS AT MAX. 4'-0"
O.C. PROVIDE MIN. 2
ANCHOR BOLTS PER
BOTTOM PLATE.
2X4 BOTTOM PLATE
CORRIDOR SHEAR WALL
5/8" SHEATHING ON
CORRIDOR SIDE WITH
MIN OF 6D NAILS AT
6" O.C. W/ 1 1/4"
PENETRATION
THICKENED SLAB
AT CORRIDOR
NOTE: ANCHOR BOLTS MUST
MEET MINIMUM REQUIREMENTS
OF IBC 2012 PARAGRAPH 2308.6.
7" M
IN
REINF SLAB,
SEE PLAN
1/2" DIA. ANCHOR
BOLTS AT MAX. 3'-6"
O.C. PROVIDE MIN. 2
ANCHOR BOLTS PER
BOTTOM PLATE.
FIELD INSTALLED
BOTTOM PLATE
SIP WALL
NOTE: ANCHOR BOLTS MUST
MEET MINIMUM REQUIREMENTS
OF IBC 2012 PARAGRAPH 2308.6.
7" M
IN
TO
P
SI
D E S
1" C
LE
AR
U N
O 4"
M
IN
EQUIPMENT DIMENSIONS
AROUND, TYP
6" ALL
HORIZ LEG
EACH END
OF #3 BAR
#3 @ 12" OC AT
PAD PERIMETER
3/4" CHAMFER
ANCHOR BOLTS AT
MECH PAD ONLY
FLOOR SLAB
SLAB REINF
ROUGHEN SLAB
SURFACE
NOTES:
1. SEE MECHANICAL AND ELECTRICAL SHEETS AND S-100 FOR LOCATION OF EQUIPMENT PADS.
2. THE PLAN DIMENSIONS OF EQUIPMENT BASES AND THEIR ANCHOR BOLT LOCATIONS,
SIZES, EMBEDMENTS, AND PROJECTIONS SHALL SUIT THE REQUIREMENTS OF THE
APPROVED EQUIPMENT FURNISHED.
3. CONTRACTOR HAS THE OPTION TO DRILL AND EPOXY EQUIPMENT ANCHOR BOLTS
W/HILTI KIT HY-150 ADHESIVE, OR APPROVED EQUAL.
4. TOP OF PAD SHALL BE LEVEL REGARDLESS OF SLAB SLOPE.
6"
EQUIPMENT
1'-0"
6"
1' -6
8" #5 CONT, TYP
#4 @ 12" EW FOR
6" CONCRETE SLAB
COMPACT FILL
FINISHED GRADE
SEE: CIVIL
CHAMFER EDGE
3'-7 5/8"
SHEET
IDENTIFICATION
1 2 3 4 5
D R
AW
N
B Y:
D
ES
I G N
B Y:
SB
M
T
BY
S
IZ
E :
FI
LE
N
A M
E:
IS
SU
E D
A
TE
C O
N
TR
AC
T
N O
S O
LI
C
IT
AT
IO
N
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
C
KD
B Y:
US Army Corps of Engineers ®
" x
4"
D
C
B
A
FI
LE
N U
M
BE
R
P
LO
T
SC
A
LE
P
LO
T D
AT
E:
A s in di ca te d
2/ 7/
2 0
:3
6 :
A M
C
AV
A L I
ER
A
F S
N D.
-0
9-
W
F-
-B
-0
OMAHA DISTRICT
J.
O
S
BO
R N
J.
O
S
BO
R N
W .B
O
EC
K
A F7
-3
-0
S-302
O M
AH
A
D
IS
TR
IC
T O
M
AH
A , N
EB
R
AS
K A
T.
C
AM
PB
EL
L
FO
U
N D A
TI
O
N S
E C
TI
O N
S A
N D
D
ET
A
IL
S
C O
N
SO
LI
D
AT
ED
D O
RM
IT
O
RY
S- 3 0
2-
3" = 1'-0"S-302
1 CONSTRUCTION JOINT
3" = 1'-0"S-302
2 CONTROL JOINT
1" = 1'-0"S-302
3 TYPICAL FOUNDATION WALL CORNER DETAILS
1" = 1'-0"S-302
4 ISOLATED CORRIDOR FOOTING
1 1/2" = 1'-0"S-302
5 DETAIL A
1 1/2" = 1'-0"S-302
6 SIP FOUNDATION CONNECTION
1 1/2" = 1'-0"S-302
CORRIDOR SHEAR WALL SLAB
CONNECTION
1 1/2" = 1'-0"S-302
7 SIP SLAB CONNECTION
3/4" = 1'-0"S-302
9 TYPICAL INTERIOR EQUIPMENT PAD
1" = 1'-0"S-302
10 TYPICAL EXTERIOR EQUIPMENT PAD DETAIL
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
ENTRY TRUSS BRG
115'-6"
S-303
RT3 TRUSS BY TRUSS
MANUFACTURER
TRUSS CONNECTIONS BY
TRUSS MANUFACTURER, TYP
RAFTERS CONNECTED WITH ROOF
BOUNDARY CLIP PER TRUSS
MANUFACTURER (NOT SHOWN) BLOCKING FOR GYPSUM
BOARD AS NEEDED
4.5"X10.5" GLULAM BEAM,
SEE NOTE 3 ON S-202
GYPSUM BOARD,
SEE ARCH
SIP PANEL,
SEE ARCH
SIP SCREW BY SIP
MANUFACTURER
ANGLED JOIST
HANGAR
ANGLED JOIST
HANGAR TO
CONNECT BLOCKING
TO SIP PANEL
ROOFING, SEE ARCH
BLOCKING
@ 24" O.C.
RT3 TRUSS
RT2 TRUSS PER TRUSS
MANUFACTURER
RAFTER PER TRUSS
MANUFACTURER
ROOF BOUNDARY
CLIP PER TRUSS
MANUFACTURER
RAFTER BY TRUSS
MANUFACTURER
NOTCH SECTION OUT OF SIP
FOR RAFTER CONNECTION
BY SIP MANUFACTURER'S
RECOMMENDATIONS
S-303
JOIST HANGAR
ANGLED JOIST HANGAR
TRUSS CONNECTION BY
TRUSS MANUFACTURER
APA RATED SHEATHING, SEE PLAN
RT3 TRUSS BY TRUSS
MANUFACTURER
SIP WALL PANEL BY
SIP MANUFACTURER
SIP ROOF PANEL BY
SIP MANUFACTURER
2X FRAMING MEMBER
FASCIA
SOFFIT
SIP CAP BY SIP
MANUFACTURER, TYP
NAILS INTO SIPS AND SIP
CAP BY SIP MANUFACTURER
6d NAILS @ 6" O.C. W/ A MIN.
PENETRATION OF 1 1/4"
4 1/2"
TWIST STRAP TIE-DOWN
WITH 1.25 KIPS LRFD
UPLIFT CAPACITY
ROOFING, SEE ARCH
CONTINUOUS SEALANT BY
SIP MANUFACTURER, TYP
CONNECTION PER SIP
MANUFACTURER. DESIGN
FOR WIND SUCTION.
2X BLOCKING
APA RATED SHEATHING,
SEE ROOF FRAMING PLAN
JOIST HANGAR
6d NAILS @ 6" O.C. W/ MIN.
PENETRATION OF 1 1/4"
SIP PANEL
HORIZONTAL
CHORD/STRUT BY
SIP MANUFACTURER
CONNECTION PER SIP
MANUFACTURER. DESIGN
FOR WIND SUCTION.
2' - 0" OVERHANG, TYP
SIP MANUFACTURE SHALL
PROVIDE ADEQUATE
CONNECTION FOR C&C
WIND UPLIFT LOADS
SIP CAP BY…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .