Am_0002-Drawing.pdf

PDF 52 KB Posted

Attached to
Consolidated Dormitory at Cavalier AFS, ND
Solicitation number
W9128F-17-B-0003
Issued by

About this file

Amendment 0002 Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GRID

6 1/2" 6 1/2" SIPS PANEL WALL W/ GWB

BOTH SIDES - SEE WALL TYPES

WALL FINISH AS SCHEDULED

- BOTH SIDES

WALL FINISH AS SCHEDULED

- BOTH SIDES

WOOD STUD WALL - SEE WALL

TYPES

PATH OF RATED BOUNDARY

AS SHOWN ON "F" SHEETS -

MAINTAIN CONTINUOUS,

RATED CONSTRUCTION ALONG

ENTIRE PATH

GRID

GRID

3/ 8"

1/

8"

1/

2"

6 1/2"

5/

8"

7/ 8"

1/

8"

1/ 2"

2" 7/

8"

1/

4"

1/ 4"

VWC AND CHAIR RAIL BELOW - AS SCHEDULED

6 1/2" SIPS PANEL WALL W/ 5/8" GWB

BOTH SIDES - TYP - SEE WALL TYPES

WALL FINISH AS SCHEDULED - BOTH SIDES

COLUMN FRAMING - SEE STRUCTURAL

ALIGN WALL SO THAT RESILIENT CHANNELS

ALIGN W/ FACE OF COLUMN FRAMING

WALL TYPE AS SCHEDULED

SEAL ALL JOINTS BETWEEN SIPS PANELS,

DIMENSIONAL LUMBER AND RIGID INSULATION @

EXTERIOR WALLS PER SIPS MANUFACTURER

RECOMMENDATIONS

VWC AND CHAIR RAIL BELOW

- AS SCHEDULED

FRAMING @ CORNER FOR

GWB AS REQ'D

STRUCTURAL SHEETING -

SEE "S" SHEETS

BATT INSULATION IN CAVITY

CORNER BEAD @ GWB CORNER - TYP

TY

P

4"

GRID

GRID

6 1/2"

1/

2"

3"

DOOR AND FRAME AS SCHEDULED

JAMB STUD - TYP

BATT INSULATION IN CAVITY AS

SCHEDULED - TYP

ALIGN FRAMING AND SIPS

PANELS TO ALLOW FOR

CONTINUOUS

APPLICATION OF GWB

5/8" GWB - SEE ROOM FINISH

SCHEDULE FOR FINISH

6 1/2" SIPS PANEL @ EXTERIOR

WALLS - TYP

SEAL ALL JOINTS BETWEEN SIPS

PANELS, DIMENSIONAL LUMBER AND

RIGID INSULATION @ EXTERIOR

WALLS PER SIPS MANUFACTURER

RECOMMENDATIONS

6 1/2" SIPS PANEL @ EXTERIOR

WALLS - TYP

5/8" GWB - SEE ROOM FINISH

SCHEDULE FOR FINISH

CONITINUOUS WEATHER

BARRIER OVER SIPS PANEL W/

FIBER CEMENT SIDING - SEE

ELEVATIONS FOR TYPE

SIPS FASTENERS - SIZE AND

SPACING AS REQ'D BY SIPS

MANUFACTURER

FIBER CEMENT TRIM - CAULK

AND PAINT ALL JOINTS BETWEEN

TRIM AND SIDING - TYP

MANUFACTURED STONE VENEER W/

SILL - HEIGHTS VARY - (BID OPTION)

- SEE ELEVATIONS - PROVIDE

SEALANT JOINT WHERE

PERPENDICULAR WALLS INTERSECT

BUILDING INTERIOR

BUILDING INTERIOR

BUILDING EXTERIOR

2 1/2"

1/

2"

GRID

GRID

6 1/2"

1/ 2"

5/8" GWB - TYP - SEE ROOM

FINISH SCHEDULE FOR FINISH

6 1/2" SIPS PANEL @ EXTERIOR

WALLS - TYP

CONITINUOUS WEATHER BARRIER

OVER SIPS PANEL W/ FIBER CEMENT

SIDING - SEE ELEVATIONS FOR TYPE

MANUFACTURED STONE

VENEER SILL BELOW - (BID

OPTION) - SEE ELEVATIONS

MITER STONE SILL AT CORNERS -

FILL JOINT W/ SEALANT OR AS

RECOMMENDED BY

MANUFACTURER

FIBER CEMENT TRIM - CAULK

AND PAINT ALL JOINTS

BETWEEN TRIM AND SIDING - TYP

SEAL ALL JOINTS BETWEEN SIPS

PANELS, DIMENSIONAL LUMBER AND

RIGID INSULATION @ EXTERIOR WALLS

PER SIPS MANUFACTURER

RECOMMENDATIONS

6 1/2" SIPS PANEL @ EXTERIOR

WALLS - TYP

DIMENSIONAL LUMBER

FRAMING AS REQ'D

SIPS FASTENERS - SIZE AND

SPACING AS REQ'D BY SIPS

MANUFACTURER

MANUFACTURED STONE

VENEER SILL BELOW - (BID

OPTION) - SEE ELEVATIONS

CONITINUOUS WEATHER

BARRIER OVER SIPS PANEL

W/ FIBER CEMENT SIDING -

SEE ELEVATIONS FOR TYPE

BUILDING INTERIOR

BUILDING EXTERIOR

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

C

KD

B Y:

US Army Corps of Engineers ®

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

'-0

4/

/ 2

4:

: 2

PM

C

AV

A L I

ER

A

F S

N D.

-0

9-

W

F-

-B

-0

OMAHA DISTRICT

AC

T

AC

T

BR

G

A F7

-3

-0

A-500

O M

AH

A

D

IS

TR

IC

T O

M

AH

A , N

EB

R

AS

K A

BR

G

PL

AN

D

ET

A

IL

S

C O

N

SO

LI

D

AT

ED

D O

RM

IT

O

RY

A- 5 0

0-

3" = 1'-0"A-500

1 RATED WALL @ SIPS DTL

3" = 1'-0"A-500

2 DTL @ SIPS TO COLUMN

3" = 1'-0"A-500

3 TYP EXTERIOR INSIDE CORNER DTL

3" = 1'-0"A-500

4 TYP EXTERIOR OUTSIDE CORNER DTL

0 3" 6" 9" 12"

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

A M

- R

EV

IS

ED

A

N D

R

ED

R

AW

N

A

PR

AC

T

File details come from the government source that posted it. Updated .