Soffit_Sections.pdf
PDF 884 KB Posted
- Solicitation number
- W9128F-16-T-E011
About this file
Soffit Sections
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ALIGN
WD DESK,
3/4" WOOD ON 3/4"
SUBSTRATE WITH
SOLID WOOD EDGE
WD FIXED SHELF
LINE OF WD
DIVIDER BEYOND
WD FASCIA,
SCRIBE TO
CEILING
PARTITION,
RE: AI.400
SERIES PLANS
CEILING,
RE: AI.410 SERIES RCPS
2' -6
3'
-0
3' -0
1'
-0
9' -6
"1'-0"
EQ
EQ
XX.AI.720
2'-0"
WD WINDOW SHELF,
3/4" WOOD ON 3/4"
SUBSTRATE WITH SOLID
WOOD EDGE
FIXED WD SHELF,
3/4" WOOD ON 3/4"
SUBSTRATE WITH SOLID
WOOD EDGE
LINE OF
FRAME BEYOND
XX.AI.720
WD FRAME
XX.AI.720
SIM
WD PANEL
NO REVEALS AT
MENTAL HEALTH UNIT
3/4" 2'-10 1/4"
1/
2"
ADJUSTABLE
CLOSURE
3'-0"
4"
EQ
EQ
1/4" SEALANT
1" 1"
2' -4
/2
9'
-0
6"
9' -6
SOLID WOOD
BENCH
LINE OF FRAME
BEYOND
WD PANEL BASE
XX.AI.720
WD PANEL
NO REVEALS AT
MENTAL HEALTH UNIT
WD FRAME
XX.AI.720
SIM
ADJUSTABLE
CLOSURE
XX.AI.720
SIM
1' -6
9'
-0
6"
9' -6
1/2" RADIUS, ALL
EXPOSED WOOD CORNERS
WD BENCH AND BACK
WD PANEL
FRAMING AS REQ'D
4" 3/
4"
1"
3/4" LINE OF FRAME BEYOND
1"
2' -4
/2
3 1/4" 1'
-6
3'-0"
MTL CLOSURE
4"
2' -4
/2
WD PANEL
OUTLET,
RE: ES DWGS
WD DESK,
WD ON MDF
SUBSTRATE
LINE OF FRAME
BEYOND
WD FRAME
WD PANEL
SOLID WOOD EDGE
NO REVEALS AT
MENTAL HEALTH UNIT
XX.AI.720
SIM
XX.AI.720
1' -6
3/4" 2'-10 1/4"
EQ EQ
1/
2"
ADJUSTABLE
CLOSURE
3'-0"
1"
9' -6
9' -0
6"
LOCKABLE CABINET
DOOR
EQ
EQ
EQ
2'
-0
/2
LEVELING DEVICE
WD SHELF,
ON SUBSTRATE WITH
SOLID WOOD EDGE
PROVIDE BLOCKING AND
STRUCTURE AS REQ'D
WD FIXED SHELF,
3/4" WOOD ON 3/4" SUBSTRATE
WITH SOLID WOOD EDGE
WD PANEL
NO REVEAL AT
MENTAL HEALTH UNIT
3/4"
3/ 4"
1" 1"
4"
3 1/4"
9' -6
6"
ADJUSTABLE
CLOSURE
1/4" SEALANT
WD PANEL
3'-0"
140' - 0"
LEVEL 3 SIGNAGE
140' - 0"
LEVEL 3 SIGNAGE
4"
2"
PLAM BASE
CABINET BUMPER
PLAM DOOR
RCP
9'-6" AFF
SOFFIT
9'-0" AFF
FINISH CEILING,
RE: AI.410 SERIES RCP
EXTERIOR WALL,
RE: AS DRAWINGS
RADIANT PANEL,
RE: MP DWGS
SHADE (EXCEPT FOR
MH PATIENT ROOMS)
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
BATT INSULATION
5/8" GYP BD ON
2-1/2" STUDS
PANEL CROSS BRACING
AS REQ.
PL01 FRAME
PL01 FRAME
3'-0"
3/4" 3 1/4" 3 7/8" 2'-0 1/4" 3 7/8"
SHIM AS REQD.
4"
MTL61 CLOSURE
TO ALLOW
EXTERIOR WALL
MOVEMENT
PAINTED
GYP BD, P10
XX.AI.720
OUTLET,
RE: ES DWGS
PLAM PANEL
140' - 0"
LEVEL 3 SIGNAGE
140' - 0"
LEVEL 3 SIGNAGE
2' -6
XX.AI.720
PLAM FRAME
RADIANT PANEL,
RE: MP DWGS
PLAM SHELF
PLAM PANEL
1' -4
1'
-6
4"
1/8" QUIRK
3/4" 3 1/4"
3'-0"
EQ EQ
9' -0
6"
9' -6
XX.AI.720
LINE OF FRAME
BEYOND
XX.AI.720
1/8" QUIRK
3/4" 3 1/4"
3'-0"
2' -6
4"
6"
XX.AI.720
4' -0
4'
-8
4"
PLAM ADJUSTABLE
SHELF
COAT ROD
PLAM ADJUSTABLE
SHELF
LINE OF PLAM
FRAME BEYOND
PLAM DOOR
6" 9'
-0
XX.AI.720
CLOTH WINDOW
SHADES
PLAM SHELF, PROVIDE
BLOCKING AND
SUPPORT AS NECESSARY.
SEE PLAN FOR EXTENT OF
SHELF
XX.AI.720
3'-0"
3/4"3 1/4"
2'-11"
1"
9' -6
1/
8"
3/ 4"
1/
4" 3/
4"
SHOP ROUTERED POCKET
TO ACCEPT 3/8" SUBSRATE,
ATTACH WITH ADHESIVE
3/8" SUBSTRATE,
PRE-FASTENED TO GYP
WITH COUNTERSUNK
SCREWS
FINISH CEILING,
RE: AI.410 SERIES RCPS
PAINTED REVEAL
CABINET BUMPER
1/
4"
3/ 8"
3/4" SUBSTRATE,
PRE FASTENED
TO GYP BD WITH
COUNTERSUNK SCREWS
SHOP ROUTERED POCKET
TO ACCEPT 3/8" SUBSTRATE,
ATTACH WITH ADHESIVE
3/4" 1/4"FRAME
CEILING PANEL
PAINTED REVEAL
3/ 4"
1/
4"
3/ 8"
FRAME
ANGLE WITTH PREMANUFACTURED
SLOT PER MANUFACTURERS SPEC
SPRING HANGAR
1/4" 3/4"
CEILING PANEL
3/4" SUBSTRATE,
PRE FASTENED
TO GYP BD WITH
COUNTERSUNK SCREWS
SHOP ROUTERED POCKET
TO ACCEPT 3/8" SUBSTRATE,
ATTACH WITH ADHESIVE
5/8" GYP ON 3/4" STUDS
FINISH CEILING
RE: AI.410 SERIES RCPS
EXPOSED SURFACES
TO BE FINISHED
EXTERIOR WALL
MULLION,
RE: AS DWGS
1/ 8"
4"
1/8"
1/8" QUIRK
CONTINUOUS
PAINTED MTL
ANGLE CLOSURE
TO MATCH
MULLION
3/4" 3 1/4"
PLAM PANEL
GAP FOR
EXPANSION
MOVEMENT
PLAM
SHELF
3/ 4"
1/
4"
3/4"1'-2 1/4"
EXTERIOR
WALL MULLION,
RE: AS DWGS
CONTINUOUS PAINTED
MTL ANGLE CLOSURE TO
MATCH MULLION
DESK SURFACE
3/4" 3 1/4"
RCP
9'-6" AFF
SOFFIT
9'-0" AFF
3/4" WD PANELEXTERIOR WALL,
RE: AS DRAWINGS
3/4" WD PANEL
RADIANT PANEL,
RE: MP DWGS
3/4"
3'-0"
3 1/4" 3 7/8" 2'-0 1/4" 3 7/8"
SHIM AS REQD.
ADJUSTABLE CLOSURE
4"
CONCEALED
SECURITY FASTENER
1/4" SEALANT
MTL61 CLOSURE
TO ALLOW
EXTEIOR WALL
MOVEMENT
1/
2"
WD PANEL
LIGHT FIXTURE,
RE: ES DWGS
COORDINATE POCKET WITH
SELECTED FIXTURE
COORDINATE LIGHT FIXTURE POCKET
WITH SELECTED FIXTURE
3 1/2"8 1/2"
4"
7/8"1' - 4 1/4"7/8"1"
RCP
9'-6" AFF
SOFFIT
9'-0" AFF
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
EXTERIOR WALL
RE: AS DWGS
RADIANT PANEL,
RE: RCP PLAN
PANEL CROSS
BRACING AS REQ.
3/4" MDF BACKED METAL
PANEL. MTL61 FINISH
BATT INSULATION
1'-7"
MTL61 CLOSURE
TO ALLOW
EXTERIOR WALL
MOVEMENT
EXTERIOR
WALL MULLION,
RE: AS DWGS
CONTINUOUS PAINTED
MTL ANGLE CLOSURE TO
MATCH MULLION
DESK SURFACE
3/4" 3 1/4"
R2
2' -4
/2
"WD PANEL
OUTLET,
RE: ES DWGS
WD DESK,
WD ON MDF
SUBSTRATE
LINE OF FRAME
BEYOND
WD FRAME
WD PANEL
SOLID WOOD EDGE
NO REVEALS AT
MENTAL HEALTH UNIT
ADJUSTABLE
CLOSURE
1' -6
1/
2" 4"
XX.AI.720
XX.AI.720
SIM
3'-0"
EQEQ3 1/4"3/4"
1"
9' -0
6"
9' -6
1/4" SEALANT
PAINTED
GYP BD, P10
BATT
INSULATION
ALUM ANGLE BY
RADIANT PANEL
MANUF.,
ALL SIDES,
MITER CORNERS
EXTERIOR WALL,
RE: AS DWGS
PANEL CROSS
BRACING
AS REQ.
3/4" 1 3/4"2'-0 1/4"3 1/4"
4" CEILING
FINISH
RE: RCP
SOFFIT
9'-0" AFF
2'-6"
WALL
BEYOND
RE: PLANS
RADIANT PANEL,
RE: MP DWGS
MTL61 CLOSURE
TO ALLOW
EXTERIOR WALL
MOVEMENT
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key PlanCONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R
ES
D
AT
IB
S
IB
N
EN
C
C
LC
C
BN
C
BC
C
BS
PS
N
PV
N
PV
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/ 6/
:1
7:
P
M XX.AI.720
MILLWORK DETAILS
08/31/2012
1/2" = 1'-0"9 SECTION - DESK AT MH
1/2" = 1'-0"3 SECTION - SHELVING AT MH
1/2" = 1'-0"5 SECTION - SEATING AT MH
1 1/2" = 1'-0"13 DETAIL - SEATING AT MH
1/2" = 1'-0"2 SECTION - DESK AT MH
1/2" = 1'-0"8 SECTION - SHELVING AT MH
3" = 1'-0"21 DETAIL - WARDROBE BASE
1 1/2" = 1'-0"10 DETAIL - RADIANT PANEL AT PATIENT ROOM (RFI2303)
1/2" = 1'-0"1 SECTION
1/2" = 1'-0"4 SECTION
1/2" = 1'-0"7 SECTION - WARDROBE
3" = 1'-0"20 DETAIL - WARDROBE HEAD
3" = 1'-0"19 DETAIL - SOFFIT
3" = 1'-0"14 DETAIL - SOFFIT
3" = 1'-0"17 DETAIL - PLAM SHELF
1 1/2" = 1'-0"23 DETAIL - CORNER PLAN
3" = 1'-0"22 DETAIL- CLOSURE @ PUNCHED OPENING
1 1/2" = 1'-0"12 DETAIL - RADIANT PANEL AT MH
3" = 1'-0"15 DETAIL - SHELF W/ LIGHT
CDI No.12 08/31/2012 JSI No. 049 01/25/2013 JSI No. 097 07/02/2014 JSI No. 106 09/11/2014 JSI No. 118 - POSTED SET 03/16/2015
1 1/2" = 1'-0"11 DETAIL - RADIANT PANEL (CORRIDOR) (RFI2303)
3" = 1'-0"16 DETAIL- CLOSURE @ CURTAIN WALL
1/2" = 1'-0"6 SECTION - DESK AT MH
1 1/2" = 1'-0"10A DETAIL - RADIANT PANEL AT EXTERIOR
5/8" GYP BD ON MTL STUDS
RADIANT PANEL, RE: MECH.
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
CURTAIN WALL -
RE: AS DWGS
PANEL CROSS BRACING
AS REQ.
ALIGN
A.C.T. CLG
VARIES, RE: PLAN
B.O. GYP BD
VARIES, RE: PLAN
7 5/8" 2' - 0 1/8" 5 1/4" 1' - 0"
O R
A S
R E
Q U
IR
E
D T
O I N
S T
A L L
R A
D
IA
N T
P A
N E
L
T Y
P
EXTRUDED MTL 61 CLOSURE PLATE TO
MATCH WIDTH OF SILL EXTENSION,
SECURE TO CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER SOFFIT
FINISH, PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
2" 6"
2"
4" 2 1/2"
1/2"
1" 8"
1"
WV01
1/4"x8"x8" STL PLATE, PT
SHIM AND WD BLKG
AS REQUIRED
STL PLATE - PT.
3' - 2"
INSULATED MTL PANEL -
RE: AS DWGS
MTL STUD FRAMING
MTL STUD FRAMING
ATC
GYP BD
RADIANT PANEL, RE: MECH.
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
CURTAIN WALL SYSTEM -
RE: AS DWGS
EXTRUDED MTL 61 CLOSURE PLATE TO
MATCH WIDTH OF SILL EXTENSION,
SECURE TO CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER SOFFIT
FINISH, PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
PANEL CROSS BRACING AS REQ.
ALIGN
A.C.T. CLG
VARIES, RE: PLAN
5 3/4" 2' - 0 1/8" 5 1/4"
3' - 0"
( 7 5/8" @ L3 CBC WEST )
ALIGN
INSULATED MTL PANEL -
RE: AS DWGS
MTL STUD BRACING
MTL STUD
A.C.T.
GYP BD
RADIANT PANEL, RE: MECH.
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
CURTAIN WALL SYSTEM - RE: AS DWGS
EXTRUDED MTL 61 CLOSURE PLATE TO
MATCH WIDTH OF SILL EXTENSION,
SECURE TO CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER SOFFIT
FINISH, PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
PANEL CROSS BRACING AS REQ.
ALIGN
A.C.T. CLG
VARIES, RE: PLAN
B.O. GYP BD
VARIES, RE: PLAN
7 5/8" 2' - 0 1/8" CLG OPENING 5 1/4"
3' - 2"
(5 3/4" @ L3 CBN EAST)
(3' - 0" @ L3 CBN EAST)
INSULATED MTL PANEL - RE AS DWGS
OPERABLE PANEL
MTL STUD BRACING
AS REQUIRED, EA. SIDE
MTL STUD
A.C.T.
GYP BD
BATT INSULATION
STEEL BRACING,
RE: STRUCT
STEEL BEAM, RE: STRUCT
OPERABLE PANEL
TRACK AND
HANGER SYSTEM
GYP. REVEAL , EA. SIDE
B.O. CEILING
RE: PLAN
EQ EQ
VARIES - RE: RCP
MTL STUD FRAMING
ACT
GYP BD
RADIANT PANEL, RE: MECH.
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
CURTAIN WALL,
RE: AS DWGS
PANEL CROSS
BRACING AS REQ.
2 1/4"2' - 0 1/8"2 1/4"1"
ACT CLG
VARIES, RE: PLAN
B.O. GYP BD
VARIES, RE: PLAN
2' - 5 5/8"
INSULATED MTL PANEL -
RE: AS DWGS
5/8" GYP BD OVER MTL STUDS
RADIANT PANEL, RE: MECH.
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
CURTAIN WALL SYSTEM -
RE: AS DWGS
EXTRUDED MTL 61 CLOSURE PLATE TO
MATCH WIDTH OF SILL EXTENSION,
SECURE TO CURTAIN WALL HEAD W/
HIGH BOND ACRYLIC TAPE AFTER SOFFIT
FINISH, PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
PANEL CROSS BRACING AS REQ.
ALIGN
A.C.T. CLG
VARIES, RE: PLAN
1" 5 3/4" 2' - 0 1/8"
MTL STUD FRAMING
INSULATED MTL PANEL -
RE: AS DWGS
MTL STUD
FRAMING
GYP BD
RADIANT PANEL -
RE: MECH.
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL SIDES,
MITER CORNERS
CURTAIN WALL,
RE: AS DWGS
PANEL CROSS
BRACING AS REQ.
1" 2 5/8"
OPENING
2' - 0 1/8"2 1/4"
ACT CLG
9' - 10"
B.O. GYP BD
9' - 9"
2 LAYERS OF
1/2" GYP BD
EXTRUDED MTL 61 CLOSURE PLATE TO
MATCH WIDTH OF SILL EXTENSION,
SECURE TO CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER SOFFIT FINISH,
PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
2' - 6"
ALIGN
INSULATED MTL PANELD -
RE: AS DWGS
5/8" GYP BD ON MTL STUDS
A.C.T. CLG
VARIES, RE: PLAN
B.O. GYP BD
VARIES, RE: PLAN
2" 6"
2"
4" 2 1/2"
RE: RCP
VARIES1/2"
1" 8"
1"
WV01
1/4"x8"x8" STL PLATE, PT
SHIM AND WD BLKG
AS REQUIRED
STL PLATE - PT.
A.C.T. CLG
VARIES, RE: PLAN
FINISH CLG MATL
RE: SCHED
MTL STUD FRAMING
BOX BEAM
5/8" GYP. ON MTL STUD
FRAMING, ALL SIDES.
PAINT RE: SCHED
MTL STUDS IN
PERPENDICULAR WALL
BEYOND, FULL HEIGHT
TO INTERSTITIAL DECK
7'-2" AFF, UNO
8'-0" AFF, UNO
GYP. BD BEYOND -
PAINT RE: SCHED
RE: RCP
1 1/2" = 1'-0"1
RADIANT PANEL CEILING
DETAIL
1 1/2" = 1'-0"2
RADIANT PANEL CEILING
DETAIL
1 1/2" = 1'-0"3
RADIANT PANEL CEILING
DETAIL
1 1/2" = 1'-0"4
OPERABLE PARTITION HEAD
1 1/2" = 1'-0"6
RADIANT PANEL CEILING
DETAIL
1 1/2" = 1'-0"5
RADIANT PANEL CEILING
DETAIL
1 1/2" = 1'-0"7
RADIANT PANEL CEILING
DETAIL
1 1/2" = 1'-0"8
GYP BD BULKHEAD DETAIL
1 1/2" = 1'-0"9
GYP BD BOX BEAM @
OPENING
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E th re e t h ir ty
-s e c o n d i n c h o n e f o o t
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/8
/2
:5 :0
P
M C
U s e rs
\r ja re c k i\ D o c u m e n ts
\A I-
T Y
P
IC
A L D
E T
A
IL
S rj a re c k i.
rv t
XX.AI.762
CEILING DETAILS
08/31/2012CDI No.12 08/31/2012
JSI No. 093 06/05/2014
JSI No. 118 - POSTED SET 03/16/2015
TEMPERED GLASS
EXTEND FRAMING TO
STRUCTURE ABOVE
HOLD HORIZONTAL
FRAMING UP 1" AT
GLAZING LOCATION
CONT. GLAZING CHANNEL
CONTINUOUS BLOCKING
5/8" GYP. BD. ON 4" METAL
STUD FRAMING, TYP.
EQEQ
XX.AI.740
SIM
3' - 2"
ACT CEILING - GYP BD SOFFIT
RADIANT PANEL - 9' - 8" A.F.F.
RADIANT PANEL W/ CROSS
BRACING AS REQD -
RE: 23 / XX.AI.761, MECH
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MFR, ALL SIDES,
MITER CORNERS
INTERSTITIAL LEVEL
ELEV. VARIES
CURTAIN WALL SYSTEM -
RE: AS DWGS
FIRE SAFING -
RE: AS DWGS
EXTRUDED MTL 61 CLOSURE
PLATE TO MATCH WIDTH OF
SILL EXTENSION, SECURE TO
CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER
SOFFIT FINISH, PROVIDE PTFE
(TEFLON) TAPE AT SURFACE IN
CONTACT W/ SOFFIT
5/8" GYP BD ON
4" MTL STUDS
5/8" GYP BD W/
CONT. J-MOLD EACH
SIDE ON MTL STUDS
4" MTL STUDS. SECURE
TO CONT. STL ANGLE AT
INTERSTITIAL LEVEL
5 1/4" 2' - 0 1/8" 7 5/8" 1"
BRACE TO STRUCT.
ATC
ALIGN
INSULATED MTL PANEL -
RE: AS DWGS
ACT - GYP BD SOFFIT
VARIES, RE: RCP
RADIANT PANEL W/ CROSS
BRACING AS REQD -
RE: 23 / XX.AI.761, MECH
BATT INSULATION
ALUM ANGLE BY RADIANT PANEL
MFR, ALL SIDES, MITER CORNERS
INTERSTITIAL LEVEL
ELEV. VARIES
CURTAIN WALL SYSTEM -
RE: AS DWGS
FIRE SAFING -
RE: AS DWGS
3' - 2"
5 1/4" 2' - 0 1/8" 7 5/8" 1"
EXTRUDED MTL 61 CLOSURE
PLATE TO MATCH WIDTH OF
SILL EXTENSION, SECURE TO
CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER
SOFFIT FINISH, PROVIDE PTFE
(TEFLON) TAPE AT SURFACE
IN CONTACT W/ SOFFIT5/8" GYP BD ON
4" MTL STUDS
5/8" GYP BD W/ CONT.
J-MOLD EACH SIDE
ON MTL STUDS
4" MTL STUDS, SECURE
TO CONT. STL ANGLE AT
INTERSTITIAL LEVEL
ALIGN
ATC
BRACE TO STRUCT
9' - 6"
A.F.F.
INTERSTITIAL FLOOR
151' - 6"
A L
IG
N
A L
IG
N
INTERSTITIAL FLR.
ABOVE
5/8" GYP. BD. ON 4" MTL
STUD FRAMING
ALIGN W/ PARTITION
AT INTERSTITIAL
LEVEL - RE: A.S. DWGS
2"
2"
ALIGN W/ PARTITION AT
INTERSTITIAL LEVEL.
RE: AS DRAWINGS
ACT CEILING
5/8" GYP. BD. ON 4" MTL
STUD FRAMING
INTERSTITIAL
FLOOR ABOVE
GYP BD SOFFIT
VARIES, RE: RCP
INTERSTITIAL FLOOR
151' - 6"
ACT
VARIES, RE: RCP
1' - 0"
8'-0" A.F.F.
INTERSTITIAL FLOOR
151' - 6"
8' - 9" A.F.F.
A L
IG
N
ALIGN W/ PARTITION
AT INTERSTITIAL FLR.
RE: AS DRAWINGS
5/8" GYP. BD. ON 4"
MTL. STUD FRAMING
TYPICAL
1' - 0"
INTERSTITIAL
FLOOR ABOVE
INTERSTITIAL FLOOR
151' - 6"
5/8" GYP BD ON 7/8" HAT
CHANNELS AT 16" O.C.
OVER 2 1/2" 'C' STUDS AT
48" O.C.ACT CEILING
5/8" GYP. BD. ON 4" MTL
STUD SOFFIT FRAMING
INTERSTITIAL
FLOOR ABOVE
8' - 6"
A.F.F.
8' - 0"
A.F.F.
10' - 0"
A.F.F.
9' - 0"
A.F.F.
PARTITION TYPE AS
SCHEDULED
BULKHEAD W/ BOX
HEADER. RE:
SCHEDULE
WALL WHERE
OCCURS
1' - 0"
RECESSED LIGHT
FIXTURE
8' - 0"
A.F.F.
INTERSTITIAL FLOOR
151' - 6"
8' - 9"
A.F.F.
A L
IG
N
1' - 0"
ACT CEILING
5/8" GYP. BD. ON 4"
MTL STUDS, TYP
INTERSTITIAL
FLOOR ABOVE
PARTITION TYPE AS
SCHEDULED
ALIGN W/ PARTITION AT
INTERSTITIAL LEVEL.
RE: AS DRAWINGS
BULKHEAD W/ BOX
HEADER. RE:
SCHEDULE
WALL WHERE
OCCURS
1' - 0"
GYP BD SOFFIT
VARIES, RE: RCP
INTERSTITIAL FLOOR
VARIES, RE: STRUCT
ACT
VARIES, RE: RCP
GYP BD SOFFIT
VARIES, RE: RCP
5/8" GYP BD ON 7/8" HAT
CHANNELS AT 16" O.C.
OVER 2-1/2" MTL STUD
FRAMING AT 48" O.C.
ACT CEILING
5/8" GYP. BD. ON 4"
MTL STUD FRAMING
INTERSTITIAL
FLOOR ABOVE
ACT CEILING
110' - 0"
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MFR, TYP ALL
SIDES, MITER CORNERS
RADIANT PANEL W/
CROSS BRACING
AS REQD -
RE: 23 / XX.AI.761, MECH
CURTAIN WALL SYSTEM -
RE : AS DRAWINGS
FIRE SAFING -
RE: AS DRAWINGS
4" METAL STUDS.
SECURE TO CONT.
STEEL ANGLE AT
INTERSTITIAL LEVEL
INTERSTITIAL LEVEL
111' - 6"
ACT CEILING
5/8" GYP BD W/ J-MOLD
EACH SIDE
1"7 5/8"2' - 0 1/8"9 1/4"
3' - 6"
ALIGN
WD BEAM -
RE: 7,12/XX.AI.766
EXTRUDED MTL 61 CLOSURE
PLATE TO MATCH WIDTH OF SILL
EXTENSION, SECURE TO CURTAIN
WALL HEAD W/ HIGH BOND ACRYLIC
TAPE AFTER SOFFIT FINISH,
PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
5/8" GYP BD OVER
4" MTL STUDS
5 1/4" @
03.AI.412-E
03.AI.413-E
3' - 0" @
03.AI.412-E
03.AI.413-E
5 5/8" @
03.AI.412-E
03.AI.413-E
INSULATED MTL PANEL -
RE AS DWGS
5/8" GYP BD ON 7/8" HAT CHANNELS
AT 16" O.C. OVER 2-1/2" MTL STUDS
@ 48" O.C. SUSPENDED FROM
STRUCTURE ABOVE
RADIANT PANEL W/ CROSS
BRACING AS REQD -
RE: 23 / XX.AI.761, MECH
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MFR, ALL SIDES,
MITER CORNERS
GYP SOFFIT
VARIES, RE: RCP
INTERSTITIAL LEVEL
ELEV. VARIES
GLAZING, INSULATED
PANEL & CURTAIN WALL
SYSTEM - RE: AS DWGS
FIRE SAFING -
RE: AS DWGS
2' - 0 1/8" 7 5/8" 1"
EXTRUDED MTL 61 CLOSURE PLATE
TO MATCH WIDTH OF SILL
EXTENSION, SECURE TO CURTAIN
WALL HEAD W/ HIGH BOND ACRYLIC
TAPE AFTER SOFFIT FINISH,
PROVIDE PTFE (TEFLON) TAPE AT
SURFACE IN CONTACT W/ SOFFIT
5/8" GYP BD ON
4" MTL STUDS
5/8" GYP BD W/ CONT.
J-MOLD EACH SIDE
ON METAL STUDS
4" MTL STUDS. SECURE
TO CONT. STL ANGLE AT
INTERSTITIAL LEVEL
ALIGN
2' - 8 3/4"
INSULATED MTL PANEL -
RE: AS DWGS
INTERSTITIAL FLOOR
STRUCTURE ABOVE
CONTRACTOR DESIGNED
EQUIPMENT SUPPORT
GRID CLG / GYP BD CLG
VARIES, SEE RCP
5/8" GYP BD ON 7/8" HAT
CHANNELS OVER 2 1/2"
'C' STUDS SUSPENDED
FROM STRUCTURE ABOVE
GASKETED WALL ANGLE
TO ALIGN W/ GYP BD CLG
RE: RCP
VARIES
INTERSTITIAL FLOOR
151' - 6"
AT03 CEILING SYSTEM
UNISTRUT CHANNEL @ 2'-2" O.C.
LIGHT FIXTURE OR DIFFUSER AS OCCURS
UNISTRUT CROSS BRACING. COORDINATE LOCATION TO CLEAR LIGHTS AND DIFFUSERS
XX.AI.761
XX.AI.761
2' - 2"
INTERSTITIAL FLOOR
STRUCTURE ABOVE
GRID CLG / GYP BD CLG
VARIES, SEE RCP
5/8" GYP BD ON 7/8" HAT
CHANNELS OVER 2 1/2"
'C' STUDS SUSPENDED
FROM STRUCTURE ABOVE
GASKETED WALL ANGLE
TO ALIGN W/ GYP BD CLG
INTERSTITIAL FLOOR
151' - 11"
AT03 CEILING SYSTEM
LEVEL 3 INTERSTITIAL
151' - 6"
TYPICAL
ABOVE O.R.
ATC - GYP BD SOFFIT
VARIES, RE: RCP
INTERSTITIAL LEVEL
ELEV. VARIES
ATC
5 1/4" 2' - 0 1/8" 5 5/8" 1"
3' - 0"
RADIANT PANEL W/ CROSS
BRACING AS REQD -
RE: 23 / XX.AI.761, MECH
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MFR, ALL SIDES,
MITER CORNERS
CURTAIN WALL SYSTEM -
RE: AS DWGS
FIRE SAFING -
RE: AS DWGS
EXTRUDED MTL 61 CLOSURE
PLATE TO MATCH WIDTH OF
SILL EXTENSION, SECURE TO
CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER
SOFFIT FINISH, PROVIDE PTFE
(TEFLON) TAPE AT SURFACE
IN CONTACT W/ SOFFIT
5/8" GYP BD W/ CONT.
J-MOLD EACH SIDE
ON MTL STUDS
4" MTL STUDS, SECURE
TO CONT. STL ANGLE AT
INTERSTITIAL LEVEL
ALIGN
BRACE TO STRUCT
5/8" GYP BD ON
4" MTL STUDS
INSULATED MTL PANEL -
RE: AS DWGS
ACT CEILING
VARIES - RE: RCP
INTERSTITIAL LEVEL
ELEV. VARIES
GYP BD SOFFIT
RADIANT PANEL - 9' - 8" A.F.F.
RADIANT PANEL W/ CROSS
BRACING AS REQD -
RE: 23 / XX.AI.761, MECH
BATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL
SIDES, MITER CORNERS
CURTAIN WALL SYSTEM -
RE: AS DWGS
FIRE SAFING -
RE: AS DWGS
EXTRUDED MTL 61 CLOSURE
PLATE TO MATCH WIDTH OF
SILL EXTENSION, SECURE TO
CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER
SOFFIT FINISH, PROVIDE PTFE
(TEFLON) TAPE AT SURFACE IN
CONTACT W/ SOFFIT
5/8" GYP BD ON
4" MTL STUDS
5/8" GYP BD W/
CONT. J-MOLD EACH
SIDE ON MTL STUDS
4" MTL STUDS. SECURE
TO CONT. STL ANGLE AT
INTERSTITIAL LEVEL
ATC
ALIGN
1"7 5/8"2' - 0 1/8"5 1/4"
3' - 2"
INSULATED MTL PANEL -
RE: AS DWGS
GYP BD CEILING
VARIES - RE: RCP
INTERSTITIAL LEVEL
ELEV. VARIES
GYP BD SOFFIT
RADIANT PANEL - 9' - 8" A.F.F.
ALIGN
3' - 2"
1"7 5/8"2' - 0 1/8"5 1/4"
RADIANT PANEL W/ CROSS
BRACING AS REQD -
RE: 23 / XX.AI.761, MECHBATT INSULATION
ALUM ANGLE BY RADIANT
PANEL MANUF., ALL
SIDES, MITER CORNERS
CURTAIN WALL SYSTEM -
RE: AS DWGS
FIRE SAFING -
RE: AS DWGS
EXTRUDED MTL 61 CLOSURE
PLATE TO MATCH WIDTH OF
SILL EXTENSION, SECURE TO
CURTAIN WALL HEAD W/ HIGH
BOND ACRYLIC TAPE AFTER
SOFFIT FINISH, PROVIDE PTFE
(TEFLON) TAPE AT SURFACE
IN CONTACT W/ SOFFIT
5/8" GYP BD ON
4" MTL STUDS
5/8" GYP BD W/
CONT. J-MOLD EACH
SIDE ON MTL STUDS
4" MTL STUDS. SECURE
TO CONT. STL ANGLE AT
INTERSTITIAL LEVEL
5/8" GYP BD ON 7/8" HAT
CHANNELS AT 16" O.C.
OVER 2-1/2" MTL STUDS @
48" O.C. SUSPENDED
FROM STRUCTURE ABOVE
INSULATED MTL PANEL -
RE: AS DWGS
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E o n e a n d o n e h a lf i n c h e s o n e f o o t
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/1
/2
:3 :5
P
M C
U s e rs
\r ja re c k i\ D o c u m e n ts
\A I-
D A
T rj a re c k i.
rv t
XX.AI.763
CEILING DETAILS
08/31/2012
1 1/2" = 1'-0"5
GLASS WINDOW / GYP SOFFIT
1 1/2" = 1'-0"3
TYP RADIANT PANEL AT
SOUTH EXTERIOR
1 1/2" = 1'-0"4
TYP RADIANT PANEL AT
EXTERIOR
1 1/2" = 1'-0"11
SOFFIT ENCLOSURE
BETWEEN SKYLIGHTS
1 1/2" = 1'-0"8
SKYLIGHT AT CORRIDOR
1 1/2" = 1'-0"9
SKYLIGHT SOFFIT AT GYP CLG
1 1/2" = 1'-0"13
SOFFIT DETAIL AT FALSE
SKYLIGHT
1 1/2" = 1'-0"10
SOFFIT DETAIL AT SKYLIGHT
1 1/2" = 1'-0"12
SOFFIT DETAIL AT FALSE
SKYLIGHT
1 1/2" = 1'-0"1
TYP RADIANT PANEL AT GYP
SOFFIT
1 1/2" = 1'-0"2
TYP RADIANT PANEL AT FULL
GYP
1 1/2" = 1'-0"6
OR UNISTRUT/CEILING
TRANSITION DTL
1 1/2" = 1'-0"7
O.R. CLG TRANSITION DETAIL
1 1/2" = 1'-0"16
TYP RADIANT PANEL AT
EXTERIOR
1 1/2" = 1'-0"14
TYP RADIANT PANEL AT
EXTERIOR
1 1/2" = 1'-0"15
TYP RADIANT PANEL AT
EXTERIOR
CDI No.12 08/31/2012
JSI No. 118 - POSTED SET 03/16/2015
| XX.AI.720_JSI 118 |
| XX.AI.762_JSI 118 |
| XX.AI.763_JSI 118 |
File details come from the government source that posted it. Updated .