Text version
UPDN
PP
PP
PP PP
PP PP
PP PP
PP
CR
01-02-PGE10
ELEV
01-02-PGE9
ELEV
B
C
D
E
E
F
G
H
C
03-02-G8-E6
ELEC
03-02-C8-H1
CHUTE
03-02-B8-E5
ELEC
03-02-B8-T3
DATA / TELECOMM
03-02-D10-T4
DATA / TELECOMM
03-02-D10-E7
ELEC
03-02-SE8
ELEV
03-02-SE7
ELEV
03-02-ST3
STAIR
03-02-ST5
STAIR
03-02-H10-01
TERRACE
7.5
03.AS.201
03.AS.301
03.AS.301
03.AS.301
03.AS.301
03.AS.302
03.AS.302
E
SEE - 1/03.AS.102-ASEE - 1/03.AS.102-A
RG.5 03
RG 03
RF.5 03
RF 03
RE.5
RD.5
RC.5 03
RD
RC
RB.5
RB
RA
R1
A.7
03.AS.204
03.AS.204
03.AS.201
27'-1 7/8"
2'-7 1/2"
6'-10 3/8"
11'-3 1/4"8'-0 1/4"2'-8 1/4"19'-0 1/2"
11 1/4" 10'-9" 8'-2" 2'-6 5/8"
1'-4 1/4"6'-2 1/2"6'-10 3/4"
A
AA
AA
A
8'-1"
19'-1 7/8" 6'-6"
6'-8 1/2"
12'-2 1/2" 8'-2 1/2"
1'-10 1/4" 5'-7 1/4"
5'-2 1/2" 8'-10 1/2"
7'-11 3/4"
8 3/4" 8'-8 1/8" 3'-7 3/8" 1/4"
03.AS.402
A
3'-3 3/4"
A
E12
32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 28'-0"
32'-0" 32'-0"
22'-0"
5'-10 1/2" 12'-0"
K4
K4
B4
B4
K4
K4
A4
A4
A1
B4
B4
K4
K4
B4
K4 K4S
K4S
B4
B4
B4
K4 K4S
B4
03.AS.313
XX.AS.502
SIM
B.5
C.2
03.AS.402-A
(@APPROX4'-0")
14EQMODULES
K4
K4S
A4
A4
5'-6"
5'-6"
4'-1" 10 1/2"
A4
5'-6"
5'-9"
A4
A4
5'-6"
5'-6"
6'-11" 5'-6"
1.REFER TO SHEET 00.AS.002 FOR DEVICE MOUNTING HEIGHTS
2.REFER TO SHEET 00.AS.003 FOR BUILDING ENCLOSURE NOTES
AND DESIGN CRITERIA.
3.REFER TO LEVEL 1 PLAN SHEET FOR EXTERIOR WALL
DIMENSIONS AND DETAIL REFERENCES UNLESS SPECIFICALLY
SHOWN ON THIS SHEET.
4.REFER TO XX.600 SERIES FOR DOOR SCHEDULE AND DOOR
DETAILS.
5.REFER TO XX.AS.710 FOR PARTITION DETAILS AND NOTES.
6.: GL52 - IGU WITH INTEGRAL HORIZONTAL BLINDS.
REFER TO SPECS FOR FURTHER INFO
DRAWING NOTES
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E one eighth inch = one foot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/6/2015 6:51:35 P M
03.AS.102-B
LEVEL 2 PLAN - AREA B
DIAGNOSTIC AND TREATMENT
08/31/2012
1/8" = 1'-0" 1LEVEL 2 PLAN - AREA B
A
B 0'4'8'16'32' 0'4'8'16'32'
NORTH
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 118 - POSTED SET03/16/2015
Waiting Area
N
N
N
PP
PP
PP
PP
01-03-PGE7
ELEV
01-03-PGE8
ELEV
01-03-PGE9
ELEV
B
C
D
E
F
G
H
J
C
03-03-A1-T1
DATA / TELECOMM
03-03-B1-E1
ELEC
03-03-F1-E2
ELEC
03-03-G1-T2
DATA / TELECOMM
03-03-C4-E3
ELEC
03-03-F5-E4
ELEC
03-03-D10-H2
CHUTE
03-03-PE6
ELEV
03-03-PE5
ELEV
03-03-SE9
ELEV
03-03-SE10
ELEV
03-03-ST1
STAIR
03-03-ST2
STAIR
7.5
03.AS.201
03.AS.201
03.AS.202
03.AS.301
03.AS.301
03.AS.301
03.AS.301
03.AS.302
03.AS.302
03.AS.202
03.AS.202
E
SEE - 1/03.AS.103-BSEE - 1/03.AS.103-B
03.AS.202
03.AS.203
9'-11 1/4" 2'-9 7/8"
9'-1 5/8"
11'-6 1/4"7 1/4"9'-10 1/4"6'-10 1/4"3'-8 1/2"
19'-7 3/4"
11'-7" 5'-0 7/8"
5'-2 7/8"
10'-11 1/4"
7'-3 3/4" 5'-1 3/4"12'-9 1/2"
9'-0"
9'-7 1/2" 13'-0" 1 1/4"
3'-3" 9'-3 1/4"
A A
A
A
A
A
A
9 1/2"12'-2 1/2"
1'-1" 9'-6"
A
A
A
4'-3 1/2" 10'-9 1/4" 4'-2 3/4"
8'-9 1/2" 1'-1"
13'-6 1/4"5'-1 1/2"
2'-5 1/4"
32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 28'-0"
31'-9" 32'-0"
32'-0" 22'-0"
10'-0" 32'-0"
32'-0" 10'-0"
K4S
B4
K4
K4
G1
A4
K4
K4
B4
B4
B4
B4
K4
K4K4
K4
B4
GG1
B4
K4
K4
B4
B4
B4
B4
B4S
B4
GG1
B4 B4
XX.AS.524
03.AS.401
03.AS.401.A
4.6
9'-11" 2'-1"
17 MODULES @ 4'-0"
68'-0" 3'-5 1/4" 8'-6 3/4"
K4
K4
2'-5 1/4"
3'-9 1/2"
2'-7 1/4" 12'-2 3/4"
11'-7" 4'-10 1/2"
5'-5 1/4"
K4 K4
B4
K4
A4 6'-1"
6'-4"
A4
A4
5'-6"
5'-6"
5'-7" 5'-11 1/2"
A4 5'-6"
7'-4"
A45'-6"
5'-9"
G4G4
2 2
1.REFER TO SHEET 00.AS.002 FOR DEVICE MOUNTING HEIGHTS
2.REFER TO SHEET 00.AS.003 FOR BUILDING ENCLOSURE NOTES
AND DESIGN CRITERIA.
3.REFER TO LEVEL 1 PLAN SHEET FOR EXTERIOR WALL
DIMENSIONS AND DETAIL REFERENCES UNLESS SPECIFICALLY
SHOWN ON THIS SHEET.
4.REFER TO XX.600 SERIES FOR DOOR SCHEDULE AND DOOR
DETAILS.
5.REFER TO XX.AS.710 FOR PARTITION DETAILS AND NOTES.
6.: GL52 - IGU WITH INTEGRAL HORIZONTAL BLINDS.
REFER TO SPECS FOR FURTHER INFO
DRAWING NOTES
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E one eighth inch = one foot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/12/2015 2:35:03 PM
C
:\R evit Local Files\AS-C
EN
TR
AL_dan.o'riley.rvt
03.AS.103-A
LEVEL 3 PLAN - AREA A
DIAGNOSTIC AND TREATMENT
08/31/2012
1/8" = 1'-0" 1LEVEL 3 PLAN - AREA A
A
B 0'4'8'16'32' 0'4'8'16'32'
NORTH
CDI No.1208/31/2012 JSI No. 04111/16/2012
DN
DN UP
UP
N NIC
01-03-PGE10
ELEV
01-03-PGE9
ELEV
B
C
D
E
F
G
H
C
03-03-G8-E5
ELEC
03-03-B8-E6
ELEC
03-03-B8-T3
DATA / TELECOMM
03-03-D10-T4
DATA / TELECOMM
03-03-D10-E6
ELEC
03-03-C8-H1
CHUTE
03-03-SE8
ELEV
03-03-SE7
ELEV
03-03-ST3
STAIR
03-03-ST5
STAIR
7.5
03.AS.201
03.AS.301
03.AS.301
03.AS.301
03.AS.301
03.AS.302
03.AS.302
E
SEE - 1/03.AS.103-ASEE - 1/03.AS.103-A
RG.5 03
RG 03
RF.5 03
RF 03
RE.5
RD.5
RC.5 03
RD
RC
RB.5
RB
RA
R1
03.AS.204
03.AS.204
16'-8 1/2" 10'-8"
2'-7 1/2"
7'-5"
11 1/4" 10'-9" 8'-2" 2'-6 5/8"
8'-3 5/8"
12'-2 1/2" 8'-2 1/2"
A
AA
A
8'-11"9'-9 7/8"3'-8 5/8"
AA
19'-7 1/8" 6'-0 3/4"
6'-8 1/2"
A
A
A
3'-3 3/4"
1'-5 1/4"
7'-9"5'-4 1/2"
6'-1" 5'-2"
1'-7"
32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 32'-0" 28'-0"
32'-0" 32'-0"
22'-0" 10'-0"
B4
B4
K4
K4
K4
K4
A4
A4
B4
K4
K4
K4S
B4S
B4
B4
K4
K4
B4
B4
B4
K4S
K4
03.AS.402
03.AS.402-A
B4
B4
7'-9" 11'-6 1/2"
K4
K4
K4
B4
K4S
A4
A4
5'-6"
5'-6"
10 1/2" 4'-1"
A4
5'-6"
5'-9"
A4
A4
5'-6"
5'-6"
6'-11" 5'-6"
1.REFER TO SHEET 00.AS.002 FOR DEVICE MOUNTING HEIGHTS
2.REFER TO SHEET 00.AS.003 FOR BUILDING ENCLOSURE NOTES
AND DESIGN CRITERIA.
3.REFER TO LEVEL 1 PLAN SHEET FOR EXTERIOR WALL
DIMENSIONS AND DETAIL REFERENCES UNLESS SPECIFICALLY
SHOWN ON THIS SHEET.
4.REFER TO XX.600 SERIES FOR DOOR SCHEDULE AND DOOR
DETAILS.
5.REFER TO XX.AS.710 FOR PARTITION DETAILS AND NOTES.
6.: GL52 - IGU WITH INTEGRAL HORIZONTAL BLINDS.
REFER TO SPECS FOR FURTHER INFO
DRAWING NOTES
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E one eighth inch = one foot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/12/2015 3:14:09 PM
C
:\R evit Local Files\AS-C
EN
TR
AL_M
injae.Kim
.rvt
03.AS.103-B
LEVEL 3 PLAN - AREA B
DIAGNOSTIC AND TREATMENT
08/31/2012
1/8" = 1'-0" 1LEVEL 3 PLAN - AREA B
A
B 0'4'8'16'32' 0'4'8'16'32'
NORTH
CDI No.1208/31/2012
RFI Sketches
DNUP
UP
FD
FD
FD
FD
01-01-PGE3
ELEV
01-01-PGE4
ELEV
01-01-PGE5
ELEV
01-01-PGE6
ELEV
04-01-C3-E1
ELEC
04-01-C3-T1
DATA / TELECOMM04-01-D3-H1
CHUTE
04-01-F2-T2
DATA / TELECOMM
04-01-F3-E2
ELEC
04-01-ST1
STAIR
04-01-ST2
STAIR
04-01-PE4
ELEV
04-01-PE3
ELEV
04-01-SE4
ELEV
04-01-SE3
ELEV
04-01-SE17
ELEV
04-01-J2-01
TERRACE
04-01-RJR1-01
DAY RM
R1
R2
A
B
C
D
E
F
G
H
J
RA
RB
RC
RE
RF
RH
RJ
RD
04-01-D1-03
PATIENT RM, ISO
04-01-E2-02
ANTEROOM
04-01-E1-02
PAT TLT, ISO
04-01-D1-01
PATIENT RM
04-01-D2-01
PAT TLT
04-01-E1-01
PATIENT RM
04-01-D1-02
PAT TLT
04-01-D1-03B
PATIENT RM
04-01-E2-01
PAT TLT
04-01-H1-01
PATIENT RM
04-01-H1-02
PAT TLT
04-01-F1-01
PATIENT RM
04-01-F1-02
PAT TLT
04-01-F1-03
PATIENT RM
04-01-G2-01
PAT TLT
04-01-G1-01
PATIENT RM
04-01-G1-02
PAT TLT
04-01-G2-02
CLEAN LINEN
04-01-G1-03
PATIENT RM
04-01-H2-01
PAT TLT
04-01-E1-03
PATIENT RM
04-01-F2-01
PAT TLT, ISO
04-01-RCR1-05
PATIENT RM
04-01-RGR1-01
PAT TLT
04-01-RER1-02
PATIENT RM
04-01-RHR1-04
PAT TLT
04-01-RER1-04
PAT TLT
04-01-RDR1-02
PATIENT RM, ISO
04-01-RHR1-01
PAT TLT
04-01-RER1-05
PATIENT RM
04-01-RDR1-04
PAT TLT
04-01-RDR1-05
PATIENT RM
04-01-RGR1-04
PAT TLT
04-01-RHR1-02
PATIENT RM
04-01-RFR1-04
PAT TLT
04-01-RHR1-03
PUBLIC TLT
04-01-RFR1-01
PAT TLT
04-01-RFR1-02
PATIENT RM
04-01-RER1-01
PAT TLT
04-01-RFR1-03
HAC
04-01-RDR1-01
PAT TLT
04-01-A2-02
VISITOR LOUNGE
04-01-E3-01
NURSE STATION
04-01-E3-02
EXAM/TREATMENT
04-01-B3-03
NURSE
SPECIALIST
04-01-E3-04
QUIET
04-01-D3-03
NOURISH
04-01-A2-01
ENTRANCE/WAIT
04-01-A3-04
PUBLIC TLT
04-01-B3-02
OFFICE
04-01-B3-04
OFFICE
04-01-A3-01
ELEV VEST
04-01-D2-02
OBSERV
04-01-RER1-03
OBSERV
04-01-A2-04
VIEWING
04-01-RJR1-01
DAY RM
04-01-RAR1-01
LITTER STOR
04-01-D3-04
MED
04-01-A1-02
PAT TLT
04-01-A2-03
PAT TLT
04-01-B1-01
PATIENT RM
04-01-B1-02
PAT TLT
04-01-B2-01
PAT TLT
04-01-B1-03
PATIENT RM
04-01-RBR1-02
PAT TLT
04-01-RBR1-03
PAT TLT
04-01-RBR1-01
PATIENT RM
04-01-RCR1-01
PAT TLT
04-01-RCR1-04
PAT TLT
04-01-C3-03
W.C. ALCOVE
04-01-B3-01
OFFICE
04-01-A3-02
EQUIP STOR
04-01-D3-01
SOILED UTIL
04-01-E3-03
CLEAN UTIL
04-01-B3-06
OFFICE
04-01-C1-02
PAT TLT
04-01-C2-01
PAT TLT
04-01-C1-01
PATIENT RM
04-01-RBR1-04
PATIENT RM
04-01-RCR1-02
PATIENT RM
04-01-B3-05
EQUIP STOR
04-01-F1-04
STAFF TLT
04-01-RGR1-03
STAFF TLT
04-01-C3-01
CLEAN LINEN
04-01-RGR1-06
EQUIP STOR
04-01-A3-05
OFFICE
04-01-RGR1-08
STAFF
04-01-C3-04
LITTER STOR
04-01-RDR1-03
ANTEROOM
04-01-G3-01
PAT LAUNDRY 04-01-C2-02
CORRIDOR
04-01-C2-02
CORRIDOR
04-01-E2-03
CORRIDOR
04-01-RGR1-02
PATIENT RM
04-01-A3-03
HAC
04-01-D3-02
X-RAY EQUIP
ALCOVE
04-01-D3-05
ELEV VEST
04-01-C3-05
EKG ALCOVE
04-01-RFR1-05
PATIENT RM
04-01-RGR1-05
PATIENT RM
04-01-G3-02
CHARTING
ALCOVE
04-01-RCR1-03
STAFF TLT
04-01-E2-03
CORRIDOR
04-01-C2-02
CORRIDOR
04-01-C2-02
CORRIDOR
04-01-C2-02
CORRIDOR
04-01-C2-02
CORRIDOR
04-01-A3-06
VEST
04-01-C2-02
CORRIDOR
04-01-E2-03
CORRIDOR
04-01-RAR1-05
CORRIDOR
04-01-E3-06
CRASH CART
ALCOVE
04-01-E3-05
CRASH CART
ALCOVE
04-01-RAR1-02
CORRIDOR
04-01-RAR1-03
CORRIDOR
04-01-RAR1-04
CORRIDOR
K
04.AI.401-A
04.QH.401-A
04.AI.401-B
04.QH.401-B
RG
A
A
AB
B
A
B
A
A
A
A AAAAAA A
A
A
A
A
AA
A
A
A
AA
A A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A A
A
A
AA?
A
A
A
A A
A
A
A
A A A
AAAA
A
A
A
A
A
A
A
A
A A
A
A A
A
A
A
A
A
A
AA
A
A
B
A
B
B
A
A
18'-5 7/8"
WSF07
WSF08 WSF08
4K4K
4K4K
WSF07 RES5-2
WSF07 RES5-2
WSF08
WSF07
WSF08
WSF07
WSF07
WSF08
WSF02 WSF08
WSF07
CPT01
MTL03/
PL01/
SSM06
GL04
P06
P06
P06
P06
P06
P06P06
P06P06
P06
P06
P06P06
P07
P07
P07
P06
P06
P06
P06
P06
P0
P0
P0
P0
P0
P0
P0
P0
P0
P0
WSF07
AA
BB
C
A
12'-6" 21'-7 1/2" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0"
A
24'-3"
A
5'-1 1/4"5'-1 1/4"
5'-1 1/4"5'-1 1/4"
A4
A4
1.REFER TO ‘AS’ DRAWINGS FOR CORE/SHELL INFORMATION INDICATED
WITH HALF TONE GRAPHIC.
2.REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
3.REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS,
AND TYPICAL MOUNTING HEIGHTS LEGEND.
4.REFER TO SHEETS XX.AI.736 THROUGH XX.AI.736-A FOR DOOR, FRAME
AND WINDOW TYPES.
5.REFER TO 600 SERIES SHEETS BY BUILDING FOR DOOR AND FRAME
SCHEDULES.
6.FINISH INFORMATION SHOWN ON THE 100 SERIES PLANS IS LIMITED TO
FLOOR PATTERN TRANSITION LOCATIONS. REFER TO ROOM FINISH
SCHEDULES, SPECIFICATION SECTIONS 0906XX FOR COMPLETE LISTING
OF ROOM FINISHES.
7.FLOOR FINISH LINES SHALL ALIGN TO FINISH FACE OF PARTITIONS,
COLUMN GRIDS, OR CENTERLINE OF WINDOW MULLIONS AS INDICATED
ON PLANS, UNLESS DIMENSIONED OTHERWISE. WHERE FLOOR FINISHES
MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY
BENEATH THE CENTER OF THE DOOR PANEL.
8.FLOOR FINISHES AND PATTERNS SHALL CONTINUE UNDER ALL OPEN
CASEWORK AND WORKSURFACES.
9.REFER TO SHEET XX.AI.771 FOR FLOOR TRANSITION AND FINISH DETAILS.
PLAN NOTES
10.REFER TO SHEET XX.AI.731 FOR PARTITION TYPES.
11.MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
12.REFER TO SHEET 00.AI.003 FOR WALL PROTECTION LEGEND AND
NOTES.
13.REFER TO SCHEDULE OF FINISHES FOR CORNER GUARD CODES.
14.REFER TO 100 SERIES PLANS FOR DOOR AND WINDOW
DESIGNATIONS.
15.REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
16.IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY
AND IS EXCLUDED FROM CDI 12. CONSTRUCTION OF THESE SPACES AND
PURCHASING OF MATERIALS, INCLUDING ALL ARCHITECTURE,
ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, IT, AND OTHER
UTILITIES IS DEFERRED UNTIL THE EQUIPMENT IS SELECTED AND THE
FINAL CONSTRUCTION DOCUMENTS FOR THESE SPACES ARE ISSUED.
17.REFER TO SHEET XX.AS.786 FOR ELEVATOR CAB FINISH INFORMATION
18.PRIMARY NORTH/SOUTH WALL ARE ON RADIAL GRID REFER TO 05.SS.000
FOR RADIAL GRID GEOMETRY.
19. AT IBS, LEVEL 2, ALL HANDRAILS AND FIRE EXTINGUISHER CABINETS
ARE TO BE SECURITY TYPE.
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/13/2015 8:43:03 PM
C
:\R evit Local Files\AI-C
EN
TR
AL_sim on.cygielski.rvt
04.AI.101
LEVEL 1 PLAN
INPATIENT BUILDING (SOUTH)
08/31/2012
1/8" = 1'-0" 1LEVEL 1 PLAN
NORTH
0'4'8'16'32' 0'4'8'16'32'
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 118 - POSTED SET03/16/2015
UP
FD
FD
FD
FD
FD
FD
FD
FD
FD FD
FD FD
01-02-PGE3
ELEV
01-02-PGE4
ELEV
01-02-PGE5
ELEV
01-02-PGE6
ELEV
04-02-C3-E1
ELEC
04-02-C3-T1
DATA / TELECOMM
04-02-D3-H1
CHUTE
04-02-F2-T2
DATA / TELECOMM
04-02-F3-E2
ELEC
04-02-ST1
STAIR
04-02-ST2
STAIR
04-02-PE4
ELEV
04-02-PE3
ELEV
04-02-SE4
ELEV
04-02-SE3
ELEV
04-02-RAR2-01
TERRACE
04-02-J2-01
TERRACE
04-02-A1-01
TERRACE
R1
R2
A
B
C
D
E
F
G
H
J
RA
RB
RC
RE
RF
RH
RJ
RD
03-02-D10-H2
CHUTE
03-02-PE6
ELEV
04-02-H3-01
STAFF LOUNGE
04-02-RFR1-04
PATIENT RM
04-02-B1-01
PAT RM
BARIATRIC
04-02-H1-02
PAT TLT
04-02-H1-01
PATIENT RM 04-02-B1-04
PATIENT RM
04-02-A1-02
PAT TLT
04-02-RGR1-01
PATIENT RM
04-02-C1-02
PAT TLT
04-02-C1-03
PAT TLT
04-02-C1-04
PATIENT RM
04-02-RCR1-04
PATIENT RM
04-02-D1-02
PAT TLT
04-02-D1-03
PAT TLT04-02-D1-04
PATIENT RM
04-02-RAR1-04
PATIENT RM
04-02-E1-02
PAT TLT
04-02-E1-04
DAY RM
04-02-G1-04
PATIENT RM
04-02-G1-03
PAT TLT
04-02-F1-03
PAT TLT
04-02-RGR1-04
PATIENT RM
04-02-F1-02
PAT TLT
BARIATRIC
04-02-F1-04
PAT RM
BARIATRIC 04-02-C1-01
PATIENT RM
04-02-B1-02
PAT TLT
BARIATRIC
04-02-G1-02
PAT TLT
04-02-D1-01
PATIENT RM
04-02-RGR1-02
PAT TLT
04-02-RGR1-03
PAT TLT
04-02-E1-01
PATIENT RM
04-02-RFR1-03
PAT TLT
04-02-RER1-03
PAT TLT 04-02-RER1-01
PATIENT RM
04-02-RDR1-04
PATIENT RM
04-02-RDR1-02
PAT TLT
04-02-RDR1-03
PAT TLT 04-02-RDR1-01
PATIENT RM
04-02-F1-01
PATIENT RM
04-02-RCR1-02
PAT TLT
04-02-RCR1-03
PAT TLT
04-02-RCR1-01
PATIENT RM
04-02-RAR1-03
PAT TLT
04-02-RBR1-04
PAT RM
BARIATRIC
04-02-RHR1-03
PAT TLT
BARIATRIC
04-02-RBR1-01
PATIENT RM
04-02-A2-01
WAIT
04-02-A2-03
PUBLIC TLT
04-02-G2-02
INTERVIEW
04-02-RDR1-08
MED GAS STOR
04-02-F2-01
OFFICE
04-02-F3-03
OFFICE
04-02-F2-02
OFFICE
04-02-RHR1-02
PAT STOR 04-02-F3-02
STAFF TLT
04-02-B2-01
DINING
04-02-F2-02B
OFFICE
04-02-RDR1-05C
OFFICE
04-02-B3-01
DINING
04-02-B2-02
NURSE STATION
04-02-A3-01
STAFF TLT
04-02-A1-03
DAY RM
04-02-RAR1-02
DAY RM
04-02-D2-02
SECLUSION RM
04-02-D2-06
ANTEROOM
04-02-B3-03
NURSE STATION
04-02-RCR1-05
GROUP RM
04-02-RFR1-02
HAC
04-02-D2-01
SECLUSION RM
04-02-E2-04
CLEAN UTIL
04-02-E3-08
WORK
04-02-C2-04B
DICTATION
04-02-E2-02B
OFFICE
04-02-E2-02C
OFFICE
04-02-RCR1-08B
PAT TLT
04-02-E2-01
GROUP
RM/OT/ASSESSMENT
04-02-C2-03
WORK
04-02-C2-02
GROUP RM
04-02-RDR1-05
OFFICE
04-02-E2-03
SECLUSION TLT
04-02-F3-01
DINING
04-02-E1-03
EQUIP STOR
04-02-RDR1-05B
OFFICE
04-02-G2-05
OFFICE
04-02-E3-09
SOILED UTIL
04-02-RBR1-02
PAT TLT
04-02-B1-03
PAT TLT
04-02-A2-02
PUBLIC TLT
04-02-G2-03
OFFICE
04-02-RFR1-01
ACTIVITIES
04-02-G1-01
PAT RM
BARIATRIC
04-02-RCR1-06
MED
04-02-D2-03
CRASH CART
ALCOVE
04-02-B3-04
HAC
04-02-E3-06
EQUIP STOR
04-02-G3-01
STAFF LOCKERS
04-02-RCR1-08
PAT SHOWER
04-02-A2-04
LAUNDRY
04-02-F3-04
EXAM
04-02-FR1-02
STAFF TLT
04-02-RDR1-05D
OFFICE
04-02-C2-04
OFFICE
04-02-B1-05
CORRIDOR
04-02-RAR1-05
CORRIDOR
04-02-RCR1-07
CORRIDOR
04-02-C3-01
CORRIDOR
04-02-E2-05
CORRIDOR
04-02-F2-03
CORRIDOR
04-02-RER1-05
CORRIDOR
04-02-RDR1-07
CORRIDOR
04-02-RCR1-08C
VEST
04-02-B2-03
INTERVIEW
04-02-B3-05
CLEAN LINEN
04-02-RDR1-06
INTERVIEW
04-02-RHR1-04
GROUP RM
04-02-C2-01
CORRIDOR
04-02-D2-04
CORRIDOR
04-02-E3-11
CORRIDOR 04-02-E3-10
CORRIDOR
04-02-A1-05
CORRIDOR
04-02-A2-06
CORRIDOR
04-02-A2-07
ELEV VEST
04-02-RBR1-05
PAT TLT
BARIATRIC
04-02-A1-04
PATIENT RM
04-02-A3-02
CORRIDOR
04-02-A2-08
CORRIDOR
04-02-E3-11
CORRIDOR
04-02-E3-11
CORRIDOR
04-02-RER1-05
CORRIDOR
04-02-RER1-04
DAY/GROUP
04-02-E3-07
MED
04-02-E2-02
NURSE STATION
04-02-RER1-02
PAT LAUNDRY
04-02-F3-01
DINING
04-02-E3-05
CORRIDOR
04-02-E3-05
CORRIDOR
04-02-RER1-05
CORRIDOR
04-02-H1-03
PAT STOR
04-02-RHR1-01
PATIENT RM
K
04.AI.402-B
04.QH.402-A
04.QH.402-B
RG
A
A
B
A
A
A
A
B
A
A
A A
A
AA
A
A
A
A
A A
A A
A
A
A
AA
A
A
AA
AAA
A
A
A
A
A A
A
AAA
A
A
A
A
A
A
A
A
A
A
A
A A A
A
A
A
A
A
A
A
A
A
A
B
A
C
AA
A
A
A
A
A
B
A A
A
B
A
A
A
A
AA
A
A
B
A
A
AAAAAAAAAAAA
A
A A
A
A
A
A
B
A
18'-5 7/8"
WSF08
WSF07
4F
B
WSF07
WSF08
WSF08
WSF02
WSF02
WSF08
WSF07
WSF08
WSF02WSF08
RES5-2WSF07
RES5-2WSF07
RES5-2WSF07
WSF07WSF08WSF02
1'-0" TYP.
1'-0"TYP.
WSF08
WSF07
FAB02 FAB02
FAB02
FAB02
FAB02
P05
P05P05
P05
P05
P05
P05
P05P05
P05P05
P05
P05
P0
P0
P0
P0
P0
P0
P0
P0
P0
P05
P0 5 P05
P05
P05
P04
P04 P04
WSF08
WSF02
P04 P04
B
A
A
4C
4F
4D
11'-11 1/2"
12'-6" 21'-7 1/2" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0" 35'-0"2'-9"
A
04.AI.402-A
A
1.REFER TO ‘AS’ DRAWINGS FOR CORE/SHELL INFORMATION INDICATED
WITH HALF TONE GRAPHIC.
2.REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
3.REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS,
AND TYPICAL MOUNTING HEIGHTS LEGEND.
4.REFER TO SHEETS XX.AI.736 THROUGH XX.AI.736-A FOR DOOR, FRAME
AND WINDOW TYPES.
5.REFER TO 600 SERIES SHEETS BY BUILDING FOR DOOR AND FRAME
SCHEDULES.
6.FINISH INFORMATION SHOWN ON THE 100 SERIES PLANS IS LIMITED TO
FLOOR PATTERN TRANSITION LOCATIONS. REFER TO ROOM FINISH
SCHEDULES, SPECIFICATION SECTIONS 0906XX FOR COMPLETE LISTING
OF ROOM FINISHES.
7.FLOOR FINISH LINES SHALL ALIGN TO FINISH FACE OF PARTITIONS,
COLUMN GRIDS, OR CENTERLINE OF WINDOW MULLIONS AS INDICATED
ON PLANS, UNLESS DIMENSIONED OTHERWISE. WHERE FLOOR FINISHES
MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY
BENEATH THE CENTER OF THE DOOR PANEL.
8.FLOOR FINISHES AND PATTERNS SHALL CONTINUE UNDER ALL OPEN
CASEWORK AND WORKSURFACES.
9.REFER TO SHEET XX.AI.771 FOR FLOOR TRANSITION AND FINISH DETAILS.
PLAN NOTES
10.REFER TO SHEET XX.AI.731 FOR PARTITION TYPES.
11.MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
12.REFER TO SHEET 00.AI.003 FOR WALL PROTECTION LEGEND AND
NOTES.
13.REFER TO SCHEDULE OF FINISHES FOR CORNER GUARD CODES.
14.REFER TO 100 SERIES PLANS FOR DOOR AND WINDOW
DESIGNATIONS.
15.REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
16.IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY
AND IS EXCLUDED FROM CDI 12. CONSTRUCTION OF THESE SPACES AND
PURCHASING OF MATERIALS, INCLUDING ALL ARCHITECTURE,
ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, IT, AND OTHER
UTILITIES IS DEFERRED UNTIL THE EQUIPMENT IS SELECTED AND THE
FINAL CONSTRUCTION DOCUMENTS FOR THESE SPACES ARE ISSUED.
17.REFER TO SHEET XX.AS.786 FOR ELEVATOR CAB FINISH INFORMATION
18.PRIMARY NORTH/SOUTH WALL ARE ON RADIAL GRID REFER TO 05.SS.000
FOR RADIAL GRID GEOMETRY.
19. AT IBS, LEVEL 2, ALL HANDRAILS AND FIRE EXTINGUISHER CABINETS
ARE TO BE SECURITY TYPE.
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/13/2015 8:43:28 PM
C
:\R evit Local Files\AI-C
EN
TR
AL_sim on.cygielski.rvt
04.AI.102
LEVEL 2 PLAN
INPATIENT BUILDING (SOUTH)
08/31/2012
1/8" = 1'-0" 1LEVEL 2 PLAN
NORTH
0'4'8'16'32' 0'4'8'16'32'
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 05807/22/2013 JSI No. 09707/02/2014
Existing Windows Contain Integral Blinds
O
FD
01-03-PGE3
ELEV
01-03-PGE4
ELEV
01-03-PGE5
ELEV
01-03-PGE6
ELEV
04-03-C3-E1
ELEC04-03-D3-H1
CHUTE
04-03-F2-T2
DATA / TELECOMM
04-03-F3-E2
ELEC
04-03-C3-T1
DATA / TELECOMM
04-03-ST1
STAIR
04-03-ST2
STAIR
04-03-PE4
ELEV
04-03-PE3
ELEV
04-03-SE4
ELEV
04-03-SE3
ELEV
04-03-J2-01
TERRACE
R1
R2
A
B
C
D
E
F
G
H
J
RA
RB
RC
RE
RF
RH
RJ
RD
03-03-D10-H2
CHUTE
03-03-PE6
ELEV
04-03-D2-02
STAFF
TLT/SHOWER04-03-D2-03
STAFF LOCKERS
04-03-D2-05
EKG ALCOVE
04-03-B1-01
PAT RM
BARIATRIC
04-03-B1-02
PAT TLT
04-03-B1-03
PAT TLT
04-03-B1-04
PATIENT RM04-03-C1-01
PATIENT RM
04-03-C1-02
PAT TLT
04-03-C1-03
PAT TLT
04-03-C1-04
PATIENT RM
04-03-D1-01
PATIENT RM, NEG
PRES
04-03-D1-02
PAT TLT
04-03-D1-03
PAT TLT
04-03-D1-04
PATIENT RM
04-03-E1-01
PATIENT RM, NEG
PRES
04-03-E1-02
PAT TLT
04-03-E1-03
PAT TLT
04-03-E1-04
PATIENT RM
04-03-F1-01
PATIENT RM, NEG
PRES
04-03-F1-02
PAT TLT
04-03-F1-03
PAT TLT
04-03-F1-04
PATIENT RM
04-03-G1-01
PATIENT RM
04-03-G1-02
PAT TLT
04-03-G1-03
PAT TLT
04-03-G1-04
PATIENT RM
04-03-H1-01
POS PRES
PATIENT RM
04-03-H1-02
PAT TLT
04-03-H1-03
POS PRES
ANTEROOM
04-03-RDR1-02
PAT TLT
04-03-RHR1-03
PAT TLT
04-03-RCR1-04
POS PRES
PATIENT RM
04-03-RGR1-04
PATIENT RM 04-03-RGR1-02
PAT TLT
04-03-RGR1-03
PAT TLT
04-03-RGR1-01
PATIENT RM
04-03-RFR1-01
PATIENT RM
04-03-RFR1-02
PAT TLT
04-03-RFR1-03
PAT TLT
04-03-RDR1-04
PATIENT RM, NEG
PRES
04-03-RER1-04
PATIENT RM
04-03-RER1-02
PAT TLT
04-03-RER1-03
PAT TLT
04-03-RFR1-04
PATIENT RM, NEG
PRES
04-03-RER1-01
PATIENT RM
04-03-RHR1-02
PAT TLT
04-03-RDR1-03
PAT TLT
04-03-RAR1-04
PATIENT RM, NEG
PRES BARIATRIC
04-03-RHR1-04
PATIENT RM
04-03-RCR1-03
PAT TLT
04-03-RHR1-01
PATIENT RM
04-03-RDR1-01
PATIENT RM
04-03-RBR1-02
PAT TLT
04-03-RBR1-03
PAT TLT
04-03-RBR1-01
PATIENT RM
04-03-RBR1-04
PATIENT RM
04-03-RAR1-02
PAT TLT
04-03-RAR1-03
PAT TLT
04-03-RAR1-01
PATIENT RM
04-03-A3-03
STAFF TLT
04-03-E2-05
X-RAY MACH
ALCOVE
04-03-E2-02
CRASH CART
ALCOVE
04-03-F3-02
HAC
04-03-C2-04B
OFFICE
04-03-A1-03
OFFICE
04-03-C2-04
OFFICE
04-03-D2-06B
OFFICE
04-03-C2-03B
OFFICE 04-03-A2-01
WAIT
04-03-G2-04
STAFF TLT
04-03-H2-01
STAFF
LOUNGE/LOCKERS
04-03-B2-02
OFFICE
04-03-B3-02
CLEAN LINEN
04-03-C2-01
SOILED UTIL
04-03-B3-05
CLEAN UTIL
04-03-F3-08
MED GAS STOR
04-03-D3-02
OFFICE
04-03-E3-02
MED
04-03-F2-01
WORK
04-03-E3-06
SOILED UTIL
04-03-E3-05
CLEAN LINEN
04-03-E2-03
CLEAN UTIL
04-03-E3-01
NURSE STATION
04-03-G2-03
CLEAN UTIL
04-03-A1-01
CONF
04-03-A3-01
PUBLIC TLT
04-03-A3-02
PUBLIC TLT
04-03-E3-03
CRASH CART
ALCOVE
04-03-E2-01
NURSE STATION
04-03-G3-02
CRASH CART
ALCOVE
04-03-A3-05
ELEV VEST
04-03-G2-01
NURSE STATION
04-03-A1-02
OFFICE
04-03-B3-01
EQUIP STOR
04-03-G2-05
EQUIP STOR
04-03-F3-09
NOURISH
04-03-F3-03
CONSULT
04-03-D2-06C
OFFICE
04-03-D2-06
OFFICE
04-03-B2-06
MED
04-03-B3-03
NURSE STATION
04-03-B2-03
NURSE STATION
04-03-F3-04
W.C. ALCOVE
04-03-B3-04
NOURISH
04-03-C2-02B
OFFICE
04-03-C2-02
OFFICE
04-03-C3-02B
OFFICE
04-03-D3-01
OFFICE
04-03-D3-01B
OFFICE 04-03-C3-02
OFFICE
04-03-D3-01C
OFFICE
04-03-F3-01
W.C. ALCOVE
04-03-C3-01
OFFICE
04-03-D3-02B
OFFICE
04-03-A3-06
HAC
04-03-C2-03
OFFICE
04-03-D2-04
FOOD CART
ALCOVE
04-03-C2-05
MONITORING
04-03-RCR1-02
POS PRES
ANTEROOM
04-03-A1-05
CORRIDOR
04-03-B2-08
CORRIDOR
04-03-RBR1-05
CORRIDOR
04-03-A3-04
CORRIDOR
04-03-RFR1-01B
CORRIDOR
04-03-RFR1-01B
CORRIDOR
04-03-F3-01B
CORRIDOR
04-03-RCR1-05
CORRIDOR
04-03-B3-06
CRASH CART
ALCOVE
04-03-RGR1-55
CLEAN LINEN
04-03-A2-02
WAIT
04-03-A1-05
CORRIDOR
04-03-B2-05
HEART CART
ALCOVE
04-03-C2-06
MONITORING
04-03-B2-01
EXAM
04-03-B2-08
CORRIDOR
04-03-B2-08
CORRIDOR
04-03-B2-08
CORRIDOR
04-03-RBR1-05
CORRIDOR
04-03-RFR1-01B
CORRIDOR
04-03-RFR1-01B
CORRIDOR
04-03-RFR1-01B
CORRIDOR
04-03-G2-01
NURSE STATION
04-03-F3-01B
CORRIDOR
04-03-F3-01B
CORRIDOR
04-03-E3-07
NURSE
STATION_STOR
04-03-E2-04
NURSE
STATION_STOR
04-03-B2-04
NURSE
STATION_STOR
04-03-B3-07
NURSE
STATION_STOR
04-03-B3-07
NURSE
STATION_STOR
K
04.AI.403-A
04.AI.403-B
04.QH.403-A
04.QH.403-B
RG
A
A
A
A
B
A
A
A
A
A
AAAAAA
A
A
A AAA
A
B
A
A
A
AA
A
A
AA
AA
A
A
A
A
A
A
A
A
A
A
B
A
A
A
A
A
A
A
A
A
A
A
A A
B
A
A
A
A A
A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
A
A
A
A
A
A
A
A
A
A A
AAA
A
A
A
A
A
A
A
A
A A
C
18'-5 7/8"
WSF07
WSF07
WSF07
WSF07
4H
4J 4J
4H 4H
4J
4H
4J
4H
4J
4H 4H
4J4J4J
4H
4H 4H
4J4J
4J 4J
4H 4H
4H
4H
4J 4J
4J
4H
4H 4H
4J4J
4H 4H
4J4J
4H 4H
4J4J
4H 4H
4J4J
4H 4H
4J4J
4H 4H
4J4J
4H
4J
B
P05
P05
P05
P05
P05
P05
P05
P05 P05
P05
P05
P05
P05
P0
P0
P0
P0
P0
P0
P0
P0 5 P0
P0
P04 P04
P04 P04
P04
P04 P04
RES5-2
WSF07 RES5-2
WSF07 RES5-2
WSF02 WSF08WSF08 WSF02WSF02WSF08WSF02WSF08 WSF02
WSF08
WSF07
WSF08
WSF08
WSF07
WSF08
WSF07
P05
P05
P05
P05
P05
B
A
4D
35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"21'-7 1/2"
A
A
B
1.REFER TO ‘AS’ DRAWINGS FOR CORE/SHELL INFORMATION INDICATED
WITH HALF TONE GRAPHIC.
2.REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
3.REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS,
AND TYPICAL MOUNTING HEIGHTS LEGEND.
4.REFER TO SHEETS XX.AI.736 THROUGH XX.AI.736-A FOR DOOR, FRAME
AND WINDOW TYPES.
5.REFER TO 600 SERIES SHEETS BY BUILDING FOR DOOR AND FRAME
SCHEDULES.
6.FINISH INFORMATION SHOWN ON THE 100 SERIES PLANS IS LIMITED TO
FLOOR PATTERN TRANSITION LOCATIONS. REFER TO ROOM FINISH
SCHEDULES, SPECIFICATION SECTIONS 0906XX FOR COMPLETE LISTING
OF ROOM FINISHES.
7.FLOOR FINISH LINES SHALL ALIGN TO FINISH FACE OF PARTITIONS,
COLUMN GRIDS, OR CENTERLINE OF WINDOW MULLIONS AS INDICATED
ON PLANS, UNLESS DIMENSIONED OTHERWISE. WHERE FLOOR FINISHES
MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY
BENEATH THE CENTER OF THE DOOR PANEL.
8.FLOOR FINISHES AND PATTERNS SHALL CONTINUE UNDER ALL OPEN
CASEWORK AND WORKSURFACES.
9.REFER TO SHEET XX.AI.771 FOR FLOOR TRANSITION AND FINISH DETAILS.
PLAN NOTES
10.REFER TO SHEET XX.AI.731 FOR PARTITION TYPES.
11.MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
12.REFER TO SHEET 00.AI.003 FOR WALL PROTECTION LEGEND AND
NOTES.
13.REFER TO SCHEDULE OF FINISHES FOR CORNER GUARD CODES.
14.REFER TO 100 SERIES PLANS FOR DOOR AND WINDOW
DESIGNATIONS.
15.REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
16.IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY
AND IS EXCLUDED FROM CDI 12. CONSTRUCTION OF THESE SPACES AND
PURCHASING OF MATERIALS, INCLUDING ALL ARCHITECTURE,
ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, IT, AND OTHER
UTILITIES IS DEFERRED UNTIL THE EQUIPMENT IS SELECTED AND THE
FINAL CONSTRUCTION DOCUMENTS FOR THESE SPACES ARE ISSUED.
17.REFER TO SHEET XX.AS.786 FOR ELEVATOR CAB FINISH INFORMATION
18.PRIMARY NORTH/SOUTH WALL ARE ON RADIAL GRID REFER TO 05.SS.000
FOR RADIAL GRID GEOMETRY.
19. AT IBS, LEVEL 2, ALL HANDRAILS AND FIRE EXTINGUISHER CABINETS
ARE TO BE SECURITY TYPE.
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/13/2015 8:44:01 PM
C
:\R evit Local Files\AI-C
EN
TR
AL_sim on.cygielski.rvt
04.AI.103
LEVEL 3 PLAN
INPATIENT BUILDING (SOUTH)
08/31/2012
1/8" = 1'-0" 1LEVEL 3 PLAN
NORTH
0'4'8'16'32' 0'4'8'16'32'
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 05807/22/2013 JSI No. 118 - POSTED SET03/16/2015
1 111
DN
UP
FD
04-01-SE17
ELEV
05-01-C3-E2
ELEC
05-01-F2-T1
DATA / TELECOMM
05-01-F3-E1
ELEC
05-01-C3-T2
DATA / TELECOMM
05-01-D3-H1
CHUTE
05-01-J1-01
TERRACE
05-01-ST2
STAIR
05-01-ST1
STAIR
05-01-PE2
ELEV
05-01-PE1
ELEV
05-01-SE2
ELEV
05-01-SE1
ELEV
05-01-RAR1-07
CORRIDOR
05-01-RHR1-01
HORTICULTURE
05-01-RAR1-01
CORRIDOR
05-01-A1-E3
ELEC
J
H
G
F
E
D
C
B
A
RG
RH
RJ
RF
RE
RD
RC
RB
RA
R2
R1
05-01-C2-02
STOR
05-01-B2-02
CYSTOSCOPY
05-01-B3-02
EXAM/TREAT
05-01-G2-04
STOR
05-01-B2-01
RECOVERY
05-01-D1-01
PHYS THERAPY
05-01-G1-02
SECR/WAIT
05-01-H1-01
OFFICE
05-01-F2-03
OFFICE 05-01-E1-01
THERAPEUTIC
POOL
05-01-RJR1-01
MEDITATION
05-01-RHR1-01
HORTICULTURE
05-01-RGR1-01
PATIENT ED
05-01-RCR1-01
HOME LEARNING
05-01-B3-07
PAT TLT
05-01-A2-01
WAIT
05-01-F3-01
INTERVIEW
05-01-RGR1-02
OFFICE
05-01-G2-06
OFFICE
05-01-G1-01
OFFICE
05-01-H1-02
OFFICE
05-01-F1-03
OFFICE
05-01-RDR1-03
CONF
05-01-G1-03
OFFICE
05-01-F2-02
OFFICE
05-01-E3-02
FEMALE
DRESSING
05-01-D3-02
ELEV VEST
05-01-G2-05
EQUIP STOR
05-01-C3-03
CLEAN UTIL
05-01-C3-02
SOILED UTIL
05-01-B3-03
DRESSING
05-01-B3-04
PAT SHOWER
05-01-A2-03
NURSE STATION
05-01-A3-05
OFFICE
05-01-B3-05
PAT TLT
05-01-A3-06
HAC
05-01-RBR1-01
PHARMACY
05-01-B3-08
PAT TLT
05-01-C1-01
OFFICE
05-01-A1-01
EXAM/TREATMENT
05-01-A1-02
EXAM/TREATMENT
05-01-A1-03
EXAM
05-01-B1-01
EXAM/TREATMENT
05-01-B1-02
EXAM/TREATMENT
05-01-RHR1-03
STAFF LOUNGE
05-01-G3-01
OFFICE
05-01-G2-02
HOME CARE
COORD
05-01-G2-03
HOME CARE
COORD
05-01-G2-01
OFFICE
05-01-C1-03
OFFICE
05-01-RGR1-03
OFFICE
05-01-F3-02
OFFICE
05-01-C1-02
OFFICE
05-01-A1-04
RECEPT
05-01-RAR1-08
PAT STOR
05-01-B1-03
EXAM/TREATMENT
05-01-D3-01
OFFICE
05-01-A3-01
PUBLIC TLT
05-01-B3-06
CLEAN LINEN
HOLD
05-01-RER1-01
OCC THERAPY
05-01-RDR1-02
BEDROOM
05-01-RDR1-01
TLT
05-01-RCR1-02
TLT
05-01-RFR1-03
ROLL IN SHOWER
05-01-RFR1-02
ACTIVITIES
05-01-A3-02
PUBLIC TLT
05-01-C2-01
INSTRUMENT
CLEANING
05-01-RAR1-02
WAIT
05-01-RAR1-06
DINING/SERVING
05-01-H2-02
STAFF TLT
05-01-RCR1-03
CLOSET
05-01-E3-01
TLT
05-01-RFR1-01
TLT
05-01-F1-01
MALE DRESSING
05-01-G3-02
HAC
05-01-H2-01
OFFICE
05-01-RHR1-02
STAFF LOCKERS
05-01-RAR1-04
STORAGE
05-01-RAR1-05
MULTIPURPOSE
05-01-RAR1-09
INTERNET CAFÉ
05-01-B1-04
CORRIDOR
05-01-A3-07
ELEV VEST
05-01-RAR1-11
CORRIDOR
05-01-RAR1-01
CORRIDOR
05-01-B3-01
CORRIDOR
05-01-RAR1-01
CORRIDOR
05-01-C3-01
UROLOGY
05-01-RAR1-03
CONF
05-01-RAR1-10
SERVERY
05-01-RAR1-07
CORRIDOR
05-01-FR1-03
CORRIDOR
05-01-F1-04
CORRIDOR
05-01-B1-04
CORRIDOR
05-01-RAR1-01
CORRIDOR
05-01-F1-04
CORRIDOR
05-01-D1-01
PHYS THERAPY
05-01-FR1-03
CORRIDOR
05-01-RBR1-02
PHARMACY
K
05.AI.401-A
05.AI.401-B
05.QH.401-A
05.QH.401-C
05.QH.401-C
05.QH.401-B
AAAAAAA
A
A
B
A
A
A
A
A
B
A
AA
A AA
A
AA
B
AA
AAAAAA
AAAAA
A
A
A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A A
A
B
A
A
A
A A A
A ?
A A
AB
A
A
A
A
A
B
B
A
A
BB
A
B
B
AA
B
B
C
B
C
7'-11 5/8"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"21'-7 1/2"12'-6"
EQ3'-10 5/8"EQ3'-10 5/8"EQ3'-10 5/8"EQ3'-10 5/8"
11'-11 3/8" 18'-6"
24'-3"
36'-25/8"
36'-11/4"
36'-11/4" 36'-11/4"
36'-11/4"
36'-11/4"
36'-11/4"
36'-11/4"
17'-8"
WSF07
WSF08
05.AI.401-C
05.AI.401-C
P06P06P06P06P06P06
P07
P07
P06
P06
P07
P0
P0
P0
P0
P0
CC03
DRAPERY
MTL01/PL01/SSM07
FOOD SERVICE
CUSTOM FRONT &
TRAY SLIDE
WSF07
CPT01
WSF07CPT01
RES5-2WSF07
WSF07
WSF08
WSF08WSF02WSF02WSF08
WSF08WSF02
WSF07
WSF08
WSF08
WSF07
WSF07
WSF08
RES5-2WSF07
MTL03/
PL01/
SSM06
WSF08WSF07
FG01
1'-0" TYP.
1'-0" TYP.
5D
5F
5K
5H
N6.9
N6.9
E.5
A
A
5C
5J
5EB
A
C
1.REFER TO ‘AS’ DRAWINGS FOR CORE/SHELL INFORMATION INDICATED
WITH HALF TONE GRAPHIC.
2.REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
3.REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS,
AND TYPICAL MOUNTING HEIGHTS LEGEND.
4.REFER TO SHEETS XX.AI.736 THROUGH XX.AI.736-A FOR DOOR, FRAME
AND WINDOW TYPES.
5.REFER TO 600 SERIES SHEETS BY BUILDING FOR DOOR AND FRAME
SCHEDULES.
6.FINISH INFORMATION SHOWN ON THE 100 SERIES PLANS IS LIMITED TO
FLOOR PATTERN TRANSITION LOCATIONS. REFER TO ROOM FINISH
SCHEDULES, SPECIFICATION SECTIONS 0906XX FOR COMPLETE LISTING
OF ROOM FINISHES.
7.FLOOR FINISH LINES SHALL ALIGN TO FINISH FACE OF PARTITIONS,
COLUMN GRIDS, OR CENTERLINE OF WINDOW MULLIONS AS INDICATED
ON PLANS, UNLESS DIMENSIONED OTHERWISE. WHERE FLOOR FINISHES
MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY
BENEATH THE CENTER OF THE DOOR PANEL.
8.FLOOR FINISHES AND PATTERNS SHALL CONTINUE UNDER ALL OPEN
CASEWORK AND WORKSURFACES.
9.REFER TO SHEET XX.AI.771 FOR FLOOR TRANSITION AND FINISH DETAILS.
PLAN NOTES
10.REFER TO SHEET XX.AI.731 FOR PARTITION TYPES.
11.MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
12.REFER TO SHEET 00.AI.003 FOR WALL PROTECTION LEGEND AND
NOTES.
13.REFER TO SCHEDULE OF FINISHES FOR CORNER GUARD CODES.
14.REFER TO 100 SERIES PLANS FOR DOOR AND WINDOW
DESIGNATIONS.
15.REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
16.IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY
AND IS EXCLUDED FROM CDI 12. CONSTRUCTION OF THESE SPACES AND
PURCHASING OF MATERIALS, INCLUDING ALL ARCHITECTURE,
ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, IT, AND OTHER
UTILITIES IS DEFERRED UNTIL THE EQUIPMENT IS SELECTED AND THE
FINAL CONSTRUCTION DOCUMENTS FOR THESE SPACES ARE ISSUED.
17.REFER TO SHEET XX.AS.786 FOR ELEVATOR CAB FINISH INFORMATION
18.PRIMARY NORTH/SOUTH WALL ARE ON RADIAL GRID REFER TO 05.SS.000
FOR RADIAL GRID GEOMETRY.
19. AT IBS, LEVEL 2, ALL HANDRAILS AND FIRE EXTINGUISHER CABINETS
ARE TO BE SECURITY TYPE.
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/13/2015 8:44:35 PM
C
:\R evit Local Files\AI-C
EN
TR
AL_sim on.cygielski.rvt
05.AI.101
LEVEL 1 PLAN
INPATIENT BUILDING (NORTH)
08/31/2012
1/8" = 1'-0" 1LEVEL 1 PLAN
NORTH
0'4'8'16'32' 0'4'8'16'32'
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 05807/22/2013 JSI No. 118 - POSTED SET03/16/2015
DN
UP
FD FD
05-02-C3-E1
ELEC
05-02-C3-T1
DATA / TELECOMM
05-02-F3-E2
ELEC
05-02-F2-T2
DATA / TELECOMM
05-02-D3-H1
CHUTE
05-02-J1-01
TERRACE
05-02-ST2
STAIR
05-02-ST1
STAIR
05-02-PE2
ELEV
05-02-PE1
ELEV
05-02-SE2
ELEV
05-02-SE1
ELEV
J
H
G
F
E
D
C
B
A
RG
RH
RJ
RF
RE
RD
RC
RB
RA
R2
R1
05-02-B3-07
EQUIP STOR
05-02-A1-01
PAT RM
BARIATRIC
05-02-A1-02
PAT TLT
05-02-A1-03
PAT TLT
05-02-A1-04
PATIENT RM
05-02-B1-01
PATIENT RM
05-02-B1-02
PAT TLT
05-02-B1-03
PAT TLT
05-02-B1-04
PATIENT RM
05-02-C1-01
PATIENT RM
05-02-C1-02
PAT TLT
05-02-C1-03
PAT TLT
05-02-C1-04
PATIENT RM
05-02-D1-01
PATIENT RM, NEG
PRES
05-02-D1-02
PAT TLT
05-02-D1-03
PAT TLT
05-02-D1-04
PATIENT RM, NEG
PRES
05-02-E1-01
PATIENT RM, NEG
PRES
05-02-E1-02
PAT TLT
05-02-E1-03
PAT TLT
05-02-E1-04
PATIENT RM
05-02-F1-01
PATIENT RM
05-02-F1-02
PAT TLT
05-02-F1-03
PAT TLT
05-02-F1-04
PATIENT RM
05-02-G1-01
PATIENT RM
05-02-G1-02
PAT TLT
05-02-G1-03
PAT TLT
05-02-G1-04
PATIENT RM
05-02-H1-01
PATIENT RM
05-02-H1-02
PAT TLT
05-02-H2-02
NURSE
SUBSTATION
05-02-G2-03
STAFF TLT
05-02-G3-03B
INTERVIEW
05-02-RHR1-04
OFFICE
05-02-F3-01
HAC
05-02-RHR1-02
POS PRES
ANTEROOM
05-02-RHR1-03
PAT TLT
05-02-RHR1-01
POS PRES
PATIENT RM
05-02-RGR1-04
PATIENT RM
05-02-RGR1-02
PAT TLT
05-02-RGR1-03
PAT TLT
05-02-RFR1-02
PAT TLT
05-02-RFR1-03
PAT TLT
05-02-RFR1-01
PATIENT RM
05-02-RER1-02
PAT TLT
05-02-RER1-03
PAT TLT 05-02-RER1-01
PATIENT RM, NEG
PRES
05-02-RDR1-01
PATIENT RM, NEG
PRES BARIATRIC
05-02-RDR1-02
PAT TLT
05-02-RDR1-03
PAT TLT
05-02-RDR1-04
PATIENT RM
05-02-RCR1-04
PATIENT RM
05-02-RCR1-02
PAT TLT
05-02-RCR1-03
PAT TLT
05-02-RCR1-01
PATIENT RM 05-02-RBR1-04
PATIENT RM
05-02-RBR1-02
PAT TLT
05-02-RBR1-03
PAT TLT
05-02-RBR1-01
PATIENT RM 05-02-RAR1-04
PATIENT RM
05-02-RAR1-02
PAT TLT
05-02-RAR1-03
PAT TLT
05-02-RAR1-01
PAT RM
05-02-A2-02
CLASSROOM/CONF
05-02-C3-01
STAFF LOUNGE
05-02-B2-08
BED
05-02-B2-03
TLT
05-02-B2-02
TLT
05-02-B2-05
BED
05-02-B3-04
TLT
05-02-B3-01
BED
05-02-B2-01
TLT
05-02-B3-02
BED
05-02-B3-03
BED
05-02-B3-06
TLT
05-02-B3-05
TLT
05-02-B2-06
BED
05-02-B2-04
TLT
05-02-B2-07
BED
05-02-C2-01
CONF
05-02-E2-06
CONSULT
05-02-A2-01
WAIT
05-02-A3-02
PUBLIC TLT
05-02-G3-01B
OFFICE
05-02-E3-07
EDUCATOR
05-02-D3-04
OFFICE
05-02-E2-07
NOURISH
05-02-E2-01
NURSE STATION
05-02-D3-02
OFFICE
05-02-E2-08
MED GAS STOR
05-02-E2-04
SOILED UTIL
05-02-E2-05B
CLEAN UTIL
05-02-E3-05
NURSE STATION
05-02-D2-02
STAFF LOCKERS
05-02-D2-04
STAFF TLT
05-02-D2-05
STAFF TLT
05-02-D2-03
STAFF
LOUNGE/LOCKERS
05-02-F3-02B
OFFICE
05-02-A3-01
GREETER
05-02-F3-03
X-RAY MACH
ALCOVE
05-02-F2-01
OFFICE
05-02-A3-07
W.C. ALCOVE
05-02-C3-02
OFFICE
05-02-A3-03
PUBLIC TLT
05-02-G3-01
OFFICE
05-02-C3-02B
OFFICE
05-02-D3-03
OFFICE
05-02-E3-07B
ONCOLOGY CNS
05-02-G2-05
OFFICE
05-02-G3-03
STOR
05-02-C2-03
LINEN CLOSET05-02-E2-05
MED
05-02-D3-04B
OFFICE
05-02-D2-06
FOOD CART
ALCOVE
05-02-F2-01B
OFFICE
05-02-F3-02
OFFICE
05-02-D3-03B
DISCHARGE
PLANNER
05-02-RAR1-05
CORRIDOR
05-02-D2-08
CORRIDOR
05-02-E1-05
CORRIDOR
05-02-G2-06
CORRIDOR
05-02-F3-04
CORRIDOR
05-02-C2-04
CORRIDOR
05-02-B3-08
CORRIDOR
05-02-A2-03
CORRIDOR
05-02-A3-04
ELEV VEST
05-02-A3-06
HAC
05-02-E3-08
CLEAN LINEN
05-02-E1-05
CORRIDOR
05-02-D2-07
EKG ALCOVE
05-02-C2-02
OFFICE
05-02-D1-05
CORRIDOR
05-02-G2-04
WORK
05-02-E2-06B
CRASH CART
ALCOVE
05-02-F2-02
EQUIP STOR
05-02-E2-09
CRASH CART
ALCOVE
05-02-E2-06C
LACTATION
05-02-D2-08
CORRIDOR
05-02-D2-08
CORRIDOR
05-02-F3-04
CORRIDOR
05-02-F3-04
CORRIDOR
05-02-E1-05
CORRIDOR
05-02-RFR1-04
PATIENT RM
05-02-RGR1-01
PATIENT RM
05-02-RER1-04
PATIENT RM
05-02-E3-05A
NURSE
STATION_STOR
05-02-E2-01A
NURSE
STATION_STOR
K
05.AI.402-A
05.AI.402-B
05.QH.402-A
05.QH.402-B
A
AAA
A
A
AAA
B
A
A
A
AA
A A
A
AAAAAAA AAAA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
AA
A
A A
AA A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A
A
A B
A
B A
A
A
A
A
A A
A
A
A
A
A
A
A
A
A
A
AA
A A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
A
A
AA
A
7'-11 5/8"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"21'-7 1/2"12'-6"2'-9"
36'-25/8"
36'-11/4"
36'-11/4" 36'-11/4"
36'-11/4"
36'-11/4"
36'-11/4"
36'-11/4"
17'-8"
18'-6" 24'-3"
2'-10"
WSF08
WSF07
B
RES5-2
WSF07
RES5-2
WSF07 RES5-2
WSF07 RES5-2
WSF02WSF02WSF08 WSF02WSF08 WSF02 WSF08WSF02
WSF08
WSF07
WSF07
WSF08
WSF07
WSF08
WSF08
WSF07
P05P05
P05P05
P05P05
P05P05
P05P05
P05P05
P05P05
P05
P05P05 P05
P05
P05
P05
P0
P0
P0
P0
P0
P0
P0
P0
P0
P0
P06
P06
P06
P06
P06
P06 P06
P04 P04
P04
P04
1'-0" TYP.
01-02-A9-04
CORRIDOR,
PATNT
A
A
A
11'-11 1/2"
1.REFER TO ‘AS’ DRAWINGS FOR CORE/SHELL INFORMATION INDICATED
WITH HALF TONE GRAPHIC.
2.REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
3.REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS,
AND TYPICAL MOUNTING HEIGHTS LEGEND.
4.REFER TO SHEETS XX.AI.736 THROUGH XX.AI.736-A FOR DOOR, FRAME
AND WINDOW TYPES.
5.REFER TO 600 SERIES SHEETS BY BUILDING FOR DOOR AND FRAME
SCHEDULES.
6.FINISH INFORMATION SHOWN ON THE 100 SERIES PLANS IS LIMITED TO
FLOOR PATTERN TRANSITION LOCATIONS. REFER TO ROOM FINISH
SCHEDULES, SPECIFICATION SECTIONS 0906XX FOR COMPLETE LISTING
OF ROOM FINISHES.
7.FLOOR FINISH LINES SHALL ALIGN TO FINISH FACE OF PARTITIONS,
COLUMN GRIDS, OR CENTERLINE OF WINDOW MULLIONS AS INDICATED
ON PLANS, UNLESS DIMENSIONED OTHERWISE. WHERE FLOOR FINISHES
MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY
BENEATH THE CENTER OF THE DOOR PANEL.
8.FLOOR FINISHES AND PATTERNS SHALL CONTINUE UNDER ALL OPEN
CASEWORK AND WORKSURFACES.
9.REFER TO SHEET XX.AI.771 FOR FLOOR TRANSITION AND FINISH DETAILS.
PLAN NOTES
10.REFER TO SHEET XX.AI.731 FOR PARTITION TYPES.
11.MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
12.REFER TO SHEET 00.AI.003 FOR WALL PROTECTION LEGEND AND
NOTES.
13.REFER TO SCHEDULE OF FINISHES FOR CORNER GUARD CODES.
14.REFER TO 100 SERIES PLANS FOR DOOR AND WINDOW
DESIGNATIONS.
15.REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
16.IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY
AND IS EXCLUDED FROM CDI 12. CONSTRUCTION OF THESE SPACES AND
PURCHASING OF MATERIALS, INCLUDING ALL ARCHITECTURE,
ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, IT, AND OTHER
UTILITIES IS DEFERRED UNTIL THE EQUIPMENT IS SELECTED AND THE
FINAL CONSTRUCTION DOCUMENTS FOR THESE SPACES ARE ISSUED.
17.REFER TO SHEET XX.AS.786 FOR ELEVATOR CAB FINISH INFORMATION
18.PRIMARY NORTH/SOUTH WALL ARE ON RADIAL GRID REFER TO 05.SS.000
FOR RADIAL GRID GEOMETRY.
19. AT IBS, LEVEL 2, ALL HANDRAILS AND FIRE EXTINGUISHER CABINETS
ARE TO BE SECURITY TYPE.
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E one eighth inch = one foot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/6/2015 6:41:58 P M
05.AI.102
LEVEL 2 PLAN
INPATIENT BUILDING (NORTH)
08/31/2012
1/8" = 1'-0" 1LEVEL 2 PLAN
NORTH
0'4'8'16'32' 0'4'8'16'32'
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 05807/22/2013 JSI No. 118 - POSTED SET03/16/2015
1 1 1
UP
05-03-C3-E1
ELEC
05-03-C3-T1
DATA / TELECOMM05-03-D3-H1
CHUTE
05-03-F3-E2
ELEC
05-03-F2-T2
DATA / TELECOMM
05-03-ST2
STAIR
05-03-ST1
STAIR
05-03-PE2
ELEV
05-03-PE1
ELEV
05-03-SE2
ELEV
05-03-SE1
ELEV
05-03-J1-01
TERRACE
J
H
G
F
E
D
C
B
A
RG
RH
RJ
RF
RE
RD
RC
RB
RA
R2
R1
05-03-A1-01
PAT RM
BARIATRIC
05-03-A1-02
PAT TLT
05-03-A1-03
PAT TLT
05-03-A1-04
PATIENT RM
05-03-F1-01
PATIENT RM, NEG
PRES
05-03-B1-02
PAT TLT
05-03-B1-03
PAT TLT
05-03-B1-04
PATIENT RM
05-03-C1-01
PATIENT RM
05-03-C1-02
PAT TLT
05-03-C1-03
PAT TLT
05-03-C1-04
PATIENT RM
05-03-H1-01
PATIENT RM
05-03-D1-02
PAT TLT
05-03-D1-03
PAT TLT
05-03-B1-01
PATIENT RM
05-03-E1-01
PATIENT RM, NEG
PRES
05-03-E1-02
PAT TLT
05-03-E1-03
PAT TLT
05-03-E1-04
PATIENT RM
05-03-D1-04
PATIENT RM
05-03-F1-02
PAT TLT
05-03-F1-03
PAT TLT
05-03-F1-04
PATIENT RM
05-03-G1-01
PATIENT RM
05-03-G1-02
PAT TLT
05-03-G1-03
PAT TLT
05-03-G1-04
PATIENT RM
05-03-D1-01
PATIENT RM, NEG
PRES
05-03-H1-02
PAT TLT
05-03-RHR1-02
POS PRES
ANTEROOM
05-03-RHR1-03
PAT TLT
05-03-RDR1-04
PATIENT RM
05-03-H2-01
NURSE
SUBSTATION 05-03-F2-02
EQUIP STOR
05-03-E3-06
OFFICE
05-03-E2-04
CRASH CART
ALCOVE
05-03-F3-02
HAC
05-03-RGR1-04
PATIENT RM
05-03-RGR1-02
PAT TLT
05-03-RGR1-03
PAT TLT
05-03-RGR1-01
PATIENT RM
05-03-RFR1-02
PAT TLT
05-03-RFR1-03
PAT TLT 05-03-RFR1-01
PATIENT RM
05-03-RER1-04
PATIENT RM
05-03-RER1-02
PAT TLT
05-03-RER1-03
PAT TLT
05-03-RAR1-01
PAT RM
05-03-RHR1-01
POS PRES
PATIENT RM
05-03-RDR1-02
PAT TLT
05-03-RDR1-03
PAT TLT
05-03-RDR1-01
PATIENT RM, NEG
PRES BARIATRIC 05-03-RCR1-04
PATIENT RM
05-03-RCR1-02
PAT TLT
05-03-RCR1-03
PAT TLT
05-03-RCR1-01
PATIENT RM 05-03-RBR1-04
PATIENT RM
05-03-RBR1-02
PAT TLT
05-03-RBR1-03
PAT TLT
05-03-RBR1-01
PATIENT RM
05-03-RAR1-04
PATIENT RM
05-03-RAR1-02
PAT TLT
05-03-RAR1-03
PAT TLT05-03-RER1-01
PATIENT RM, NEG
PRES
05-03-B2-01
GYM
05-03-G2-02
LIVING/MULTIPURPOSE
05-03-G2-01
APARTMENT
05-03-E3-04
CLEAN LINEN
05-03-E2-05
CLEAN UTIL
05-03-E2-06
SOILED UTIL
05-03-E2-08
NOURISH
05-03-E2-02
NURSE STATION
05-03-D3-03B
OFFICE
05-03-E2-09
MED GAS STOR
05-03-C2-01
STAFF
05-03-B3-04
SPEECH
05-03-B3-03
STOR
05-03-F2-03
LAUNDRY
05-03-D3-05
OFFICE
05-03-G2-03
DINING
05-03-B3-08B
OFFICE
05-03-B3-07B
EDUCATOR
05-03-D3-03
DISCHARGE
PLANNER
05-03-D2-01
STAFF TLT
05-03-A3-03
PUBLIC TLT
05-03-A3-08
W.C. ALCOVE
05-03-F3-03
X-RAY MACH
ALCOVE
05-03-RHR1-04
OFFICE
05-03-A3-02
PUBLIC TLT
05-03-E3-06B
OFFICE
05-03-D3-01
OFFICE
05-03-D3-01B
OFFICE
05-03-C3-05C
OFFICE
05-03-B3-07
SAFETY COORD
05-03-C3-05B
EDUCATOR
05-03-F2-01
OFFICE
05-03-D2-06
FOOD CART
ALCOVE
05-03-H1-04
ORTHO CAST
STOR
05-03-A3-04
ELEV VEST
05-03-B3-01
OFFICE
05-03-A2-01
WAIT
05-03-E2-03
MED
05-03-F2-01B
OFFICE
05-03-B3-08
OFFICE
05-03-C3-05
COORDINATOR
05-03-D2-08
STAFF
LOUNGE/LOCKERS
05-03-D2-02
STAFF LOCKERS
05-03-D2-05
STAFF TLT
05-03-B2-02
CORRIDOR
05-03-C2-04
CORRIDOR
05-03-B3-09
CORRIDOR05-03-RFR1-04
PATIENT RM
05-03-E3-05
NURSE STATION
05-03-A2-02
CONF
05-03-E2-01
CONSULT
05-03-C3-01
CLOSET
05-03-C3-02
CLOSET05-03-H3-01
TLT
05-03-A3-06
HAC
05-03-B3-06
EQUIP STOR
05-03-A3-05
STOR
05-03-C2-03
CORRIDOR
05-03-C2-03
CORRIDOR
05-03-F3-01
CORRIDOR
05-03-D3-06
CORRIDOR
05-03-D2-07
EKG ALCOVE
05-03-A3-07
LACTATION
05-03-H1-03
STAFF TLT
05-03-A3-01
CORRIDOR
05-03-E2-06B
CRASH CART
ALCOVE
05-03-F3-01
CORRIDOR
05-03-F3-01
CORRIDOR
05-03-D3-06
CORRIDOR
05-03-D3-06
CORRIDOR
05-03-C2-03
CORRIDOR
05-03-E3-05A
NURSE
STATION_STOR
05-03-E2-02A
NURSE
STATION_STOR
05-03-G2-01C
APARTMENT_STOR
K
05.AI.403-A
05.AI.403-B
05.QH.403-A
05.QH.403-B
A
A
A
B
A
A
A
B
A
A
A
A
A
A
A
B
AA AAAAAAAAAAAAA
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
AA
A
AA
A
A
A
A A
A
A
A A
A
A
A
A
A
A
A
A
A
A
A
B
A
A A
A
A
A
A
A
A
A
B
A
A
A
A
A
A
A
AA
A A
A
A
A
A
A
A
A
AA
A
A
B
A
A
B
7'-11 5/8"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"35'-0"21'-7 1/2"12'-6"2'-9"
18'-6" 24'-3"
2'-10" 11'-11 1/2"
36'-25/8"
36'-11/4"
36'-11/4" 36'-11/4"
36'-11/4"
36'-11/4"
36'-11/4"
36'-11/4"
17'-8"
WSF08
WSF08
WSF06
WSF07
WSF07
WSF07
B
RES5-2
WSF07
RES5-2
WSF07 RES5-2
WSF07 RES5-2
WSF02 WSF02 WSF02 WSF08
WSF08
WSF07
WSF07
WSF08
WSF07
WSF08
WSF08 WSF02WSF08WSF02
WSF08 WSF02
CPT01 WSF07
P04 P04
P04
P07
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P06
P0
P0
P0
P0
P0
P0
P0
P0
P0
P06
P06
P06
P06
P07 P07
P07
P06
1'-0" TYP.
1' -0
"T
YP
SIM
SIM
A C
1.REFER TO ‘AS’ DRAWINGS FOR CORE/SHELL INFORMATION INDICATED
WITH HALF TONE GRAPHIC.
2.REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
3.REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS,
AND TYPICAL MOUNTING HEIGHTS LEGEND.
4.REFER TO SHEETS XX.AI.736 THROUGH XX.AI.736-A FOR DOOR, FRAME
AND WINDOW TYPES.
5.REFER TO 600 SERIES SHEETS BY BUILDING FOR DOOR AND FRAME
SCHEDULES.
6.FINISH INFORMATION SHOWN ON THE 100 SERIES PLANS IS LIMITED TO
FLOOR PATTERN TRANSITION LOCATIONS. REFER TO ROOM FINISH
SCHEDULES, SPECIFICATION SECTIONS 0906XX FOR COMPLETE LISTING
OF ROOM FINISHES.
7.FLOOR FINISH LINES SHALL ALIGN TO FINISH FACE OF PARTITIONS,
COLUMN GRIDS, OR CENTERLINE OF WINDOW MULLIONS AS INDICATED
ON PLANS, UNLESS DIMENSIONED OTHERWISE. WHERE FLOOR FINISHES
MEET AT DOORWAYS, TRANSITION OF FINISHES SHALL OCCUR DIRECTLY
BENEATH THE CENTER OF THE DOOR PANEL.
8.FLOOR FINISHES AND PATTERNS SHALL CONTINUE UNDER ALL OPEN
CASEWORK AND WORKSURFACES.
9.REFER TO SHEET XX.AI.771 FOR FLOOR TRANSITION AND FINISH DETAILS.
PLAN NOTES
10.REFER TO SHEET XX.AI.731 FOR PARTITION TYPES.
11.MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
12.REFER TO SHEET 00.AI.003 FOR WALL PROTECTION LEGEND AND
NOTES.
13.REFER TO SCHEDULE OF FINISHES FOR CORNER GUARD CODES.
14.REFER TO 100 SERIES PLANS FOR DOOR AND WINDOW
DESIGNATIONS.
15.REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
16.IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY
AND IS EXCLUDED FROM CDI 12. CONSTRUCTION OF THESE SPACES AND
PURCHASING OF MATERIALS, INCLUDING ALL ARCHITECTURE,
ASSOCIATED MECHANICAL, PLUMBING, ELECTRICAL, IT, AND OTHER
UTILITIES IS DEFERRED UNTIL THE EQUIPMENT IS SELECTED AND THE
FINAL CONSTRUCTION DOCUMENTS FOR THESE SPACES ARE ISSUED.
17.REFER TO SHEET XX.AS.786 FOR ELEVATOR CAB FINISH INFORMATION
18.PRIMARY NORTH/SOUTH WALL ARE ON RADIAL GRID REFER TO 05.SS.000
FOR RADIAL GRID GEOMETRY.
19. AT IBS, LEVEL 2, ALL HANDRAILS AND FIRE EXTINGUISHER CABINETS
ARE TO BE SECURITY TYPE.
1112080913
03 04 05 06
Drawing Number
Building Number
Project Number Project Title
Location
DateCheckedDrawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
Date Revisions
123456789101112
D
C
B
A
554-501 REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
01 - C O
N 02 - R
ES
03 - D
AT
04 - IBS
05 - IBN
06 - EN
C 07 - C
LC
08 - C
BN
09 - C
BC
10 - C
BS
11 - PSN
12 - PVN
13 - PVS
1234567891011121314
E one eighth inch = one foot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
3/13/2015 8:44:53 PM
C
:\R evit Local Files\AI-C
EN
TR
AL_sim on.cygielski.rvt
05.AI.103
LEVEL 3 PLAN
INPATIENT BUILDING (NORTH)
08/31/2012
1/8" = 1'-0" 1LEVEL 3 PLAN
NORTH
0'4'8'16'32' 0'4'8'16'32'
CDI No.1208/31/2012 JSI No. 04901/25/2013 JSI No. 05807/22/2013 JSI No. 118 - POSTED SET03/16/2015
File details come from the government source that posted it. Updated .