Text version

CLOSE

R.H. SERVOMOTOR

U N

IT

UNIT

L.H. SERVOMOTOR

"16

GOV. CABINET

CLOSE

NOTES:

REFERENCE DRAWINGS:

B-81255-00-02

PIPING - TURBINE GOVERNORSMB15-87E119.2

ARRANGEMENT

GATE SERVOMOTOR OIL PRESSURE PIPING A-37030-66-01

RESTORING CABLE TELESCOPIC GUIDE PIN TYPE

SEE NOTE 3.

SEE SHEET E-709 FOR WIRING DETAIL.

ENCLOSURE AND WIRING PENETRATIONS TO BE NEMA 4X.

NEW MLDT TERMINAL BLOCK ENCLOSURE.

10 FEET OF MLDT SIGNAL LEADS.

3. FIELD MOUNT ENCLOSURE TO TURBINE PIT WALL WHERE SHOWN. MOUNT WITHIN

SERVOMOTOR PIPING.

2. FIELD ROUTE CONDUIT. MOUNT TO TURBINE PIT WALL. DO NOT MOUNT BACK TO

1. SEE GENERAL NOTES ON G-004.

SEE NOTE 2

SEE DRAWING M-201 FOR FURTHER DETAIL

SEE ELECTRICAL SPECIFICATIONS

NEW MLDT SIGNAL CONDUIT

P

IT

L

IN

E R

R

12'-10"8'-2"

"16 91'-11

"4 112'-1

9'-6" 22'-6"

SERVOMOTOR STROKE LENGTH

"2 12'-6

OPENING PORT

CLOSING PORT

OPENING PORT

8" PRESSURE TO OPEN

TO CLOSE

8" PRESSURE

PORT

CLOSING

IN OPEN POSITION

SERVOMOTOR SHOWN

PRESSURE TANK

PIPING TO

SEE DRAWING M-201 FOR FURTHER DETAIL.

FEED WIRE THROUGH EXISTING RACEWAY.

TERMINATE CONDUIT.

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

T

S

E V

E N R

M

IL

E S P

E

A N

S I F

/0

/2

B B

P .0

M -1

X X

X .d g n

G

H D

C J L

R

B R

IA

N B

E L L P

E

IN

S

T A

L L

P L

A N V

IE

W

G A

T E M

L D

M-101

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

B

E N

D D

A M

G

H D

C S

W H

:1

B B

P -1 .0

-3 -0 /8

" = 1'-0"2

1SCALE:

PLAN VIEW

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

M-101SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 8:43:42 AM

OMAHA DISTRICT

NOTES:

EHI AND GATE ISOLATION

SUPPLY PRESSURE FOR

SUPPLY PORT TO PROVIDE

USE AUXILIARY VALVE

CONTROL CABINET

AMERICAN GOVERNOR

OIL SUMP PENETRATION

RE-USE EXISTING

AS NEEDED

VALVE ISOLATING PLUNGERS

FOR GATE DISTRIBUTING

NEW TUBING AND FITTINGS

GATE LVDT

SEE NOTE 3

VALVE ISOLATING PLUNGERS

FOR GATE DISTRIBUTING

TUBING AND FITTINGS

NEW THREE-WAY VALVE,

ADAPTER PLATE

PILOT VALVE

48 19 00.00 26 FOR DETAIL

SEE SPECIFICATION SECTION

GOVERNOR CONTROL CABINET

NEW MOUNTING STRUCTURE FOR

PRESSURIZED OIL

SECTION 48 19 00.00 26 FOR DETAIL

PLATE SEE SPECIFICATION

AUX VALVE COVER

FIXTURE, SEE NOTE 4

MOUNTING

GATE LVDT

VALVE, SEE NOTE 3

NEW SHUT-OFF

TESTING OF PRESSURE SWITCHES

VALVE AND MANIFOLD FOR

TEST PORT BETWEEN ISOLATION

PROVIDE PRESSURE SWITCH

SWITCH MANIFOLD

NEW OIL PRESSURE

MSS SP-58.

MANUFACTURE FOR PIPE HANGERS, INSERTS AND SUPPORTS SHALL CONFORM TO

THE TUBING DURING SUDDEN PRESSURE CHANGES. MATERIAL, DESIGN AND

TO SUPPORT THE OIL PRESSURE LINES AND PREVENT VIBRATION AND MOVEMENT OF

8. PROVIDE ALL NECESSARY PIPE HANGERS AND SUPPORTS (NOT SHOWN) AS REQUIRED

VALVE COVER PLATE AND BOLTS.

AND EXISTING GOVERNOR CABINET STEEL BASE - FOR ACCESS TO NEW AUX.

7. MINIMUM CLEARANCE OF 3 INCHES REQUIRED BETWEEN NEW CONTROL CABINET

SUBMITTED FOR APPROVAL BY THE GOVERNMENT.

6. THE USE OF PIPE THREAD SEALANT (TYPE AND JOINT LOCATIONS USED) SHALL BE

FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS.

SECTION 48 19 00.00 26.

5. EHI MOUNT TO BE DESIGNED BY THE INSTALL CONTRACTOR PER SPECIFICATION

THE INSTALL CONTRACTOR PER SPECIFICATION SECTION 48 19 00.00 26.

AND DIMENSIONS. MOUNTING BRACKET AND CONNECTION DETAIL TO BE DESIGNED BY

STOP NUT FIXTURE (EXISTING CASTED PART). FIELD VERIFY EXISTING CONDITIONS

4. GATE LVDT MOUNTING DESIGN TO INCORPORATE EXISTING DISTRIBUTING VALVE

LOCKING HANDLES, SUITABLE FOR USE WITH STANDARD PADLOCKS.

SECTION 48 19 00.00 26. VALVES TO BE MANUALLY OPERATED AND PROVIDED WITH

BE USED FOR MAINTENANCE. VALVES SHALL BE SELECTED IN ACCORDANCE WITH

3. THREE-WAY VALVES AND ISOLATING SHUT-OFF VALVES SHALL BE PROVIDED AND WILL

DUPLEX FILTERS AND MANIFOLD BLOCK.

2. EHI INCLUDES GATE PROPORTIONAL VALVES, SHUTDOWN SANDWICH VALVE,

1. SEE GENERAL NOTES ON G-004.

AIR LINES NOT SHOWN FOR CLARITY

VALVE ASSEMBLY

NEW AIR BRAKE

PROPOSED LOCATION IS PREFERRED.

AND CALIBRATION.

SELECT NEW LOCATION FOR EASE OF MAINTENANCE

PROVIDED BRACKET.

TRANSDUCER (GFE) TO NEW CONTRACTOR

INSTALL NEW GOVERNOR OIL PRESSURE

PROVIDE AND FIELD ROUTE NEW AIR PRESSURE PIPING.

NEW CONTRACTOR PROVIDED BRACKET.

RELOCATE 2 BRAKE AIR PRESSURE SWITCHES TO

NEW CONTRACTOR PROVIDED BRACKET.

RELOCATE 3 GOVERNOR OIL PRESSURE SWITCHES TO

SEE NOTE 2

EHI ASSEMBLY

SEE NOTE 5

NEW EHI MOUNT

FRONT SIDE

BACK SIDE

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

/0

/2

B B

P .0

M -1

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

IN

S

T A

L L

M-111

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

E N

D D

A M

B R

IA

N B

E L L P

E

C A

B

IN

E T P

L A

N V

IE

W

G

V E

R N

O R A

C T

U A

T O

R B

B P -1 .0

-3 -0 /8

NTS

PLAN VIEW - ACTUATOR CABINET

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

M-111SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:16:12 PM

EL. 1363.0'

EL. 1353.25'

RESTORING CABLE

EL. 1361.58'

NOTES:

REFERENCE DRAWINGS:

RESTORING CABLE TELESCOPIC GUIDE PIN TYPEB-81255-00-02

PIPING - TURBINE GOVERNORSMB15-87E119.2

ARRANGEMENT

GATE SERVOMOTOR OIL PRESSURE PIPINGA-37030-66-01

TURBINE PIT PHOTO A TURBINE PIT PHOTO B

SEE NOTE 3.

SEE SHEET E-709 FOR WIRING DETAIL.

ENCLOSURE AND WIRING PENETRATIONS TO BE NEMA 4X.

NEW MLDT TERMINAL BLOCK ENCLOSURE.

SIGNAL LEADS

WITHIN 3 FEET OF MLDT

FLEX CONDUIT MAY BE USED

REDUNDANT MLDTS

SEE NOTES 4 AND 5 FOR DETAIL

RESTORING POST ADAPTER PLATE

NEW MLDT BRACKET AND

SEE SPECIFICATION SECTION 48 19 00.00 26 FOR FURTHER DETAIL.

BENDING OR BREAKING OF MLDT RODS.

ALLOW FREE ROTATION OF PLATE, TO AVOID

PLATE ATTACHMENT TO RESTORING POST STUD SHALL

AT ALL TIMES DURING OPERATION.

PLATE SHALL KEEP BOTH ROD ENDS AT EQUAL LINEAR POSITIONS

5. PROVIDE NEW MLDT RESTORING POST ATTACHMENT PLATE.

REUSE RESTORING POST STUD IF POSSIBLE.

SUPPORT BRACKETS IF POSSIBLE.

4. REUSE ANY PREVIOUSLY INSTALLED CONDUIT

SIGNAL LEADS.

WHERE SHOWN. MOUNT WITHIN 10 FEET OF MLDT

3. FIELD MOUNT ENCLOSURE TO TURBINE PIT WALL

MOUNT TO EXISTING SERVOMOTOR OIL PIPING.

2. FIELD ROUTE CONDUIT. MOUNT TO TURBINE PIT WALL. DO NOT

1. SEE GENERAL NOTES ON G-004.

TURBINE PIT PHOTO B

ROUTE THROUGH EXISTING RACEWAY

SEE TURBINE PIT PHOTO A

SEE NOTE 2

NEW MLDT SIGNAL CONDUIT

FIELD ROUTE NEW MLDT CONDUIT

PROPOSED LOCATION IS APPROXIMATE

NEW MLDT TERMINAL BOX FEED MLDT SIGNAL CABLE THROUGH EXISTING RACEWAY.

TERMINATE FIELD ROUTED CONDUIT.

/0

/2

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

B B

P .0

M -2

X X

X .d g n

G

H D

C J L

R

B R

IA

N B

E L L P

E G

H D

C S

W H

IN

S

T A

L L

E L E

V A

T

IO

N V

IE

W

G A

T E M

L D

T

M-201

:1

D

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

E N

D D

A M

B B

P -1 .0

-3 -0 /1

SCALE: 1"=1'-0"

ELEVATION VIEW

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

M-201SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 8:43:51 AM

25242322

26 27 28 29 19

33 343231

4039383735

R G RG

R

R

G A

G RAG R

BG R

BG R

BG R

6"

"2

ACTUATOR SECTIONGAUGE AND INSTRUMENT SECTION

CABLE TRAY ADAPTER

WIRING DUCT

EMERG. LIGHT, 60W. INCAN., (TYP.)

EL. 1363.0

FINISHED FLOOR

WIRINNG DUCTS

NOTES:

REFERENCE DRAWINGS:

INSTRUMENTS & CONTROLS ON GOVERNOR CABINET

DESCRIPTIONITEM

1 FLUOR. LIGHTING FIXTURE, HOLOPHANE #9012-4-NL

AIR BRAKE DUPLEX PRESSURE GAUGE

15 AIR BRAKE CONTROL

17 ACTUATOR SECTION LIGHT SWITCH

19 CO BREAK GLASS STATION

21 ANNUNCIATOR PANEL

TELEPHONE

23 GENERATOR GUIDE BRG. TEMP. INDICATOR

GENERATOR THRUST BRG. TEMP. INDICATOR

25 TURBINE BEARING OIL TEMP. INDICATOR

TURBINE BEARING TEMPERATURE INDICATOR

27 DRAFT TUBE VACUUM GAUGE

GENERATOR THRUST BRG. OIL TEMP. INDICATOR

29 TURBINE BEARING OIL PRESSURE GAUGE

SPIRAL CASE PRESSURE GAUGE

31 CO DELAYED BANK CUTOUT CONTROL SWITCH

CANOPY LIGHT SWITCH

33 ANNUNCIATOR TEST AND RESET SWITCH

INTAKE GATES EMERG. LOWER CONTROL SWITCH

35 GENERATOR THRUST BRG. H.P. LUB. OIL PUMP CONTROL SW.

HORN CUTOUT SWITCH

37 GENERATOR SPACE HEATERS CONTROL SWITCH

GENERATOR THRUST BRG. OIL PRESS. IND. LIGHT

39 UNIT COOLING WATER VALVE CONTROL SWITCH

DRAFT TUBE WATER DEPRESSOR VALVES CONTROL SW.

41 ANNUNCIATOR RELAY CABINET (BEHIND PANEL)

TURBINE BRG. OIL PUMPS CONTROL SWITCH

43 GOVERNOR MOTOR CONTACTOR

GAUGE AND INSTRUMENT SECTION LIGHT SWITCH

45 AUXILIARY RELAY 4B, 6 CONTACTS

AUXILIARY RELAY 4A, 6 CONTACTS

47 AUXILIARY RELAY 20DY, 2 CONTACTS

AUXILIARY RELAY 20DX1, 2 CONTACTS

49 AUXILIARY RELAY 63X, 6 CONTACTS

AUXILIARY RELAY 63BPX, 6 CONTACTS

51 TIME DELAY RELAY 65MSY

TIME DELAY RELAY 65MSX

52 AUXILIARY RELAY 20DX2, 2 CONTACTS

NEW HMI

PANELS. SEE NOTE 2

NEW FLUSH-MOUNTED

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

CONTROL CABINET

AMERICAN GOVERNOR

INSTALL NEW

2 NOT USED

3 NOT USED

8 NOT USED

NOT USED11

ITEM 1, (TYP.)

SEE NOTE 1

REMOVABLE PANELS

SHEAR PIN ANNUNCIATOR SWITCH

AUXILIARY RELAY 63X, RESEAL IN

G

M A

X

NOT USED

NOT USED

RELOCATED AIR BRAKE SWITCH

NOT USED

NOT USED

S E

E N

O T

E

S E

E N

O T

E

OUTLINE OF GOVERNOR CABINET FOR BIG BEND A-37030-00-01

5. FIELD VERIFY HMI SCREEN HEIGHT WILL BE APPROXIMATELY 5'8" OR LESS.

SHEET M-111.

4. PRESSURE SWITCHES (ITEM 64) NOT SHOWN ON THIS DRAWING. REFER TO

BOLTS.

GOVERNOR CABINET STEEL BASE - FOR ACCESS TO NEW AUX. VALVE COVER PLATE AND

3. MINIMUM CLEARANCE OF 3" REQUIRED BETWEEN NEW CONTROL CABINET AND EXISTING

NEW PANELS TO MOUNT FLUSH WITH GOVERNOR CABINET.

CABINET COLLAR PANEL AND THE MODIFIED FRONT PANEL. CONTRACTOR TO FABRICATE

INSTALLATION OF CONTROL CABINET, VERIFY MEASUREMENTS FOR THE CONTROL

2. FIELD VERIFY ATTACHMENT METHOD OF EXISTING CABINET PANELING. AFTER

1. SEE GENERAL NOTES ON G-004.

W

G

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

B B

P .0

M -2

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

IN

S

T A

L L

M-211

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

B

E N

D D

A M

B R

IA

N B

E L L P

E

A C

T U

A T

O R C

A B

IN

E T E

L E

V A

T

IO

N

G O

V E

R N

O R

/0

/2

W F -1

-R -0

P -1 .0

-3 -0 /1

" = 1'-0"2

1SCALE: 1

FRONT VIEW

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

M-211SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:16:40 PM

DOME LIGHT

TERMINAL BLOCK COMPARTMENT

20" O.D.

X 0.06 THICK, P/N 98017A200 OR EQUAL

(6) WASHER 0.64 O.D. X 0.36 I.D.

P/N 918474A031 OR EQUAL

- 16 UNC HEX JAM NUT8

3(2)

CASTING SHOWN (SEE NOTE 5)

" THREAD ENGAGEMENT INTO2

" LENGTH4

3 - 16 UNC ROD, 28

3(2)

A1-TEK RH1320-001

(ZVPU) SPEED SENSOR PROBES

(2) NEW ZERO VELOCITY PICKUPS

SEE NOTE 5

REFERENCE DRAWINGS:

A-37030-00-07GOVERNOR GENERATOR UNIT ASSEMBLY 20" HOUSING

A-37030-00-06P.M.G. DRIVE SUB-ASSEMBLY

AND SHOW ON SHOP DRAWINGS.

5. LOCATION SHOWN IS APPROXIMATE, INSTALL-CONTRACTOR TO FIELD MEASURE

4. TARGET AIR GAP IS 0.015 - 0.045 INCHES.

PROVIDED BY THE GOVERNMENT.

NUMBER 3700-100908 "TYPICAL INSTALLATION PLAN", TO BE

COMPONENTS AGAINST AMERICAN GOVERNOR COMPANY DOCUMENT

3. CONTRACTOR TO VERIFY REMOVAL/RETROFIT OF PMG

(QTY 2) UPPER DRIVE PIN

(QTY 2) INSULATING WASHER

(QTY 1FT) SPAGHETTI INSULATION

(QTY 2) UPPER DRIVE BUSHING

(QTY 1) BEARING LOCK WASHER

(QTY 2) BEARING

(QTY 6FT) LOCKWIRE

FOR EACH PMG WILL INCLUDE:

FURNISHED PMG REBUILD KITS. REBUILD KITS

2. THE PMGs SHALL BE REBUILT USING GOVERNMENT

1. GENERAL NOTES ON G-004.

TERMINAL BLOCK COMPARTMENT

MECHANICAL OVERSPEED SWITCH

BEARINGS, 4 (TYP.) SEE NOTE 3

NOTES:

"O.D.8

/0

/2

B B

P .0

M -5

X X

X .d g n

G

H D

C S

W H

:1

W F -1

-R -0

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

T

S T

E V

E N R

M

IL

E S P

E

A N

S I F

G

H D

C J L

R

IN

S

T A

L L

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

B

IG

B

E N

D D

A M

B R

IA

N B

E L L P

E

P M

G R

E T

R O

F

IT

D

E T

A

IL

M-501

P -1 .0

-3 -0 /1

GOVERNOR GENERATOR UNIT ASSEMBLY

A

NTS

SECTION A-A

NTS

A

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

M-501SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 8:44:05 AM

RESTORING POST

SERVOMOTOR

RE-USE EXISTING STUD AND NUT

NOTES:

SHOWN FOR CLARITY

SIGNAL CABLES NOT

REFER TO SPECEFICATIONS

MLDT COVERS NOT SHOWN FOR CLARITY.

FULLY EXTENDED (GATES CLOSED)

SERVOMOTOR SHOWN

SUCH THAT NO DEFLECTION IS PRESENT DURING NORMAL OPERATING CONDITIONS.

SHALL BE SUBMITTED FOR APPROVAL. BRACKET AND SUPPORT SHALL BE DESIGNED

SERVOMOTOR. MOUNTING HARDWARE AND ANY REQUIRED DRILLING OR TAPPING

SUBMITTED FOR APPROVAL. STEEL COMPONENTS SHALL BE PAINTED TO MATCH

3. MLDT BRACKET, SUPPORT, AND RESTORING POST ADAPTER DESIGNS SHALL BE

2. MLDT COVERS AND SIGNAL WIRES NOT SHOWN FOR CLARITY.

1. SEE GENERAL NOTES ON G-004.

SERVO LOCK HANDLE.

MLDT RODS WILL NOT INTERFERE WITH OPERATION OF MANUAL

PRIOR TO FABRICATION, FIELD VERIFY DIMENSIONS TO ENSURE

PROVIDE 6" TALL ADAPTER FOR SERVOMOTOR RESTORING POST

MANUAL SERVO LOCK HANDLE.

MLDT RODS MUST NOT INTERFERE WITH

EXPOSED MLDT CONNECTING RODS.

MLDT COVERS ARE NOT REQUIRED TO COVER

SUBMIT DETAIL FOR APPROVAL

ROTATION DURING SERVO STROKE.

PROVIDE MEANS TO PREVENT ADAPTER

WITH EQUIVALENT SIZE AND GRADE.

REPLACE RESTORING POST BOLT

DESIGNED BY CONTRACTOR.

NEW RESTORING POST ADAPTER

ROTATING OR TELESCOPING PARTS OF THE SERVOMOTOR ASSEMBLY.

BRACKET SUPPORT SHALL NOT BE MOUNTED TO ANY

ADDITIONAL BRACKET SUPPORT MAY BE NEEDED FOR RIGIDITY.

DESIGN SHALL MOUNT TO EXISTING RESTORING CABLE CONDUIT SUPPORT.

DESIGN SHOWN IS FOR REFERENCE ONLY.

NEW CONTRACTOR DESIGNED MLDT BRACKET.

MLDT BRACKET ASSEMBLY SUPPORT.

INSIDE RETAINED RESTORING CABLE SHEAVE SUPPORT, TO BE USED FOR

PROVIDE SPACERS AS NEEDED TO CENTER MLDT BRACKET ASSEMBLY SUPPORT

FOR DISASSEMBLY OF SERVOMOTOR COVER.

USING EXISTING COVER BOLTS TO ALLOW

MOUNT TO SERVOMOTOR FRONT FACE

ALL CONNECTIONS FOR BRACKET SUPPORTS TO BE WELDED.

CABLE SHEAVE SUPPORT.

RE-USE EXISTING RESTORING

4.0 MA 20MA

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

A

S I F

B B

P .0

M -5

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

IN

S

T A

L L

M-511

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

E N

D D

M

T

E M

L D

T

D E

T A

IL

/0

/2

B B

P -1 .0

-3 -0 /1

S T

E V

E N R

M

IL

E S P

E

B R

IA

N B

E L L P

E

NTS

ELEVATION - GATE MLDT

NTS

PLAN - GATE MLDT

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

M-511SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 8:44:14 AM

NOTES:

P

A

T

B

S

U

AP B T

A B

P

A

T

B

S

U

AP B T

A B

PX PLUG

POP UP

CLOSE

GATES

OPEN

GATESB

A

B

A

A BA B

NO.

SUPPLY

PRESSURE

SYSTEM

OPEN GATES

TO CLOSE

SET

PUMPINGTANK

PRESSURE

SUMP

TO SUMP

P R

E S

S U

R E T

O O

P E

N

PLUG

PRESSURE TO CLOSE

P R

E S

S U

R E S

U P

P P

L Y

DRAIN

COVER PLATE

AUX VALVE

GATE SERVOMOTOR

VALVE. SEE NOTE 2

SUPPLY SHUT-OFF

NEW PRESSURE

(DO NOT MODIFY)

TIMING NUTS

CLOSING RATE-

ASSEMBLY

REDUNDANT MLDT

PLUGPLUG

3-WAY BALL VALVEDUPLEX EHI FILTER ASSEMBLY

48 19 00.00 26 FOR DETAIL

SEE SPECIFICATION SECTION

LVDT MOUNTING BRACKET

LVDT ASSEMBLY

MANIFOLD WITH FILTERS

SANDWICH SHUTDOWN VALVE

SOLENOID OPERATED

GATE PROPORTIONAL VALVE

PISTON

PILOT

STEM

SPOOL

CONTROLET

DISTRIBUTING VALVE

DRAIN

TO SUMP

CONTROL. SEE NOTE 2

AND ISOLATING POPPET

DISTRIBUTING VALVE

NEW 3-WAY VALVE,

HYDRAULIC SCHEMATIC

NO.

MANIFOLD AND SWITCHES

NEW PRESSURE SWITCH

SWITCH MANIFOLD

VALVE TO PRESSURE

SUPPLY SHUT-OFF

NEW PRESSURE

STANDARD PADLOCKS.

OPERATED AND PROVIDED WITH LOCKING HANDLES, SUITABLE FOR USE WITH

BE SELECTED IN ACCORDANCE WITH SECTION 48 19 00.00 26. VALVES TO BE MANUALLY

VALVES SHALL BE PROVIDED AND WILL BE USED FOR MAINTANANCE. VALVES SHALL

2. VALVES FOR ISOLATING PLUNGERS AND PRESSURE SUPPLY SHUT-OFF

1. SEE GENERAL NOTES ON G-004.

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

/0

/2

B B

P .0

M -6

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

IN

S

T A

L L

M-601

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B B

P -1 .0

-3 -0 /1

B

IG

B

E N

D D

A M

B R

IA

N B

E L L P

E

V

E R

N O

R H

Y D

R A

U L

IC

S C

H E

M A

T

IC

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

M-601SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 8:44:22 AM

File details come from the government source that posted it. Updated .