PROJECT MAP

VICINITY MAP

PROJECT PHOTOGRAPH

S T

E V

E N R

M

IL

E S P

E

A N

S I F

/0

/2

L U

K E R

A Y

N O

R P

E

W F -1

-R -0

B B

P -1 .0

-0 /1

B

P .0

G -0

X X

X .d g n

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

T G

H

D C J L

R

P R

O J E

C T L

O C

A T

IO

N A

N D V

IC

IN

T Y M

A P

S

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

B

IG

B

E N

D D

A M

/0

/2

W F -1

-R -0

BIG BEND DAM

PROJECT LOCATION

G-001

B B

P -1 .0

-0 /1

DIGITAL GOVERNOR UPGRADE

BIG BEND DAM

MISSOURI RIVER, SOUTH DAKOTAOmaha District of Engineers

US Army Corps

G

H D

C S

W H

:1

G

H D

C S

W H

:1

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

G-001SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:13:39 PM

OMAHA DISTRICT

G-004

G-003

G-002

G-001

BBP1.04_G-004XXX.dgn

BBP1.04_G-003XXX.dgn

BBP1.04_G-002XXX.dgn

BBP1.04_G-001XXX.dgn

MECHANICAL GENERAL NOTES AND LEGEND

INDEX TO REFERENCE DRAWINGS

INDEX TO DRAWINGS

PROJECT LOCATION AND VICINITY MAPS

M-602

M-601

M-511

M-501

M-211

M-201

M-111

M-101

BBP1.04_M-602XXX.dgn

BBP1.04_M-601XXX.dgn

BBP1.04_M-511XXX.dgn

BBP1.04_M-501XXX.dgn

BBP1.04_M-211XXX.dgn

BBP1.04_M-201XXX.dgn

BBP1.04_M-111XXX.dgn

BBP1.04_M-101XXX.dgn

ED801

ED711

ED710

ED709

ED708

ED707

ED706

ED705

ED704

ED703

ED702

ED701

ED621

ED620

ED619

ED618

ED617

ED616

ED615

ED614

ED613

ED612

ED611

ED610

ED609

ED608

ED607

ED606

ED605

ED604

ED603

ED602

ED601

ED201

E-802

E-801

E-714

E-713

E-712

E-711

E-710

E-709

E-708

E-707

E-706

E-705

E-704

E-703

E-702

E-701

E-621

E-620

E-619

E-618

E-617

E-616

E-615

E-614

E-613

E-612

E-611

E-610

E-609

E-608

E-607

E-606

E-605

E-604

E-603

E-602

E-601

E-201

E-101

MD901

MD602

MD601

MD501

MD211

MD201

MD101

BBP1.04_MD901XXX.dgn

BBP1.04_MD602XXX.dgn

BBP1.04_MD601XXX.dgn

BBP1.04_MD501XXX.dgn

BBP1.04_MD211XXX.dgn

BBP1.04_MD201XXX.dgn

BBP1.04_MD101XXX.dgn

GOVERNOR ACTUATOR CABINET - REMOVAL

AUTOMATIC AIR BALANCING SCHEMATIC - REMOVAL

GOVERNOR - HYDRAULIC DIAGRAM - REMOVAL

PMG RETROFIT DETAIL - REMOVAL

GOVERNOR ACTUATOR CABINET - ELEVATION - REMOVAL

GATE RESTORING CABLE - ELEVATION - REMOVAL

GATE RESTORING CABLE - PLAN VIEW - REMOVAL

BBP1.04_ED801XXX.dgn

BBP1.04_ED711XXX.dgn

BBP1.04_ED710XXX.dgn

BBP1.04_ED709XXX.dgn

BBP1.04_ED708XXX.dgn

BBP1.04_ED706XXX.dgn

BBP1.04_ED705XXX.dgn

BBP1.04_ED704XXX.dgn

BBP1.04_ED703XXX.dgn

BBP1.04_ED702XXX.dgn

BBP1.04_ED701XXX.dgn

BBP1.04_ED621XXX.dgn

BBP1.04_ED620XXX.dgn

BBP1.04_ED619XXX.dgn

BBP1.04_ED618XXX.dgn

BBP1.04_ED617XXX.dgn

BBP1.04_ED616XXX.dgn

BBP1.04_ED615XXX.dgn

BBP1.04_ED614XXX.dgn

BBP1.04_ED613XXX.dgn

BBP1.04_ED612XXX.dgn

BBP1.04_ED611XXX.dgn

BBP1.04_ED610XXX.dgn

BBP1.04_ED609XXX.dgn

BBP1.04_ED608XXX.dgn

BBP1.04_ED607XXX.dgn

BBP1.04_ED606XXX.dgn

BBP1.04_ED605XXX.dgn

BBP1.04_ED604XXX.dgn

BBP1.04_ED603XXX.dgn

BBP1.04_ED601XXX.dgn

BBP1.04_ED201XXX.dgn

BBP1.04_E-802XXX.dgn

BBP1.04_E-801XXX.dgn

BBP1.04_E-714XXX.dgn

BBP1.04_E-712XXX.dgn

BBP1.04_E-711XXX.dgn

BBP1.04_E-710XXX.dgn

BBP1.04_E-709XXX.dgn

BBP1.04_E-708XXX.dgn

BBP1.04_E-706XXX.dgn

BBP1.04_E-705XXX.dgn

BBP1.04_E-704XXX.dgn

BBP1.04_E-703XXX.dgn

BBP1.04_E-702XXX.dgn

BBP1.04_E-701XXX.dgn

BBP1.04_E-621XXX.dgn

BBP1.04_E-618XXX.dgn

BBP1.04_E-617XXX.dgn

BBP1.04_E-616XXX.dgn

BBP1.04_E-615XXX.dgn

BBP1.04_E-614XXX.dgn

BBP1.04_E-608XXX.dgn

BBP1.04_E-607XXX.dgn

BBP1.04_E-606XXX.dgn

BBP1.04_E-605XXX.dgn

BBP1.04_E-604XXX.dgn

BBP1.04_E-603XXX.dgn

BBP1.04_E-601XXX.dgn

BBP1.04_E-201XXX.dgn

BBP1.04_E-101XXX.dgn

AUTOMATIC AIR BALANCING- SCHEMATIC - INSTALL

GOVERNOR - HYDRAULIC SCHEMATIC - INSTALL

GATE MLDT DETAIL - INSTALL

PMG RETROFIT DETAIL - INSTALL

GOVERNOR ACTUATOR CABINET - ELEVATION - INSTALL

GATE MLDT ELEVATION - INSTALL

GOVERNOR ACTUATOR CABINET - PLAN VIEW - INSTALL

GATE MLDT - PLAN VIEW - INSTALL

CABLE AND CONDUIT SCHEDULE - REMOVAL

UNIT CONTROL BOARD NO. 1 WIRING ACTUATOR PANEL - REMOVAL

UNIT CONTROL BOARD NO. 1 WIRING INSTRUMENT PANEL - REMOVAL

UNIT 1 WIRING DIAGRAMS GENERATOR, TURBINE & TRANSFORMER CONNECTION DIAGRAM - REMOVAL

14.4KV GENERATOR SWITCHGEAR WIRING VCB 124 - REMOVAL

NOT USED

RELAY BOARD WIRING PANEL 1RB - REMOVAL

RELAY BOARD 11G1B WIRING PANEL 2RB, PARTIAL - REMOVAL

RELAY BOARD 11G1A WIRING PANEL 2RB, PARTIAL - REMOVAL

RELAY BOARD WIRING PANEL 2RB - REMOVAL

INSTRUMENT BOARD REAR PANEL WIRING PANEL 2IBS - REMOVAL

INSTRUMENT BOARD WIRING PANEL 2IB - REMOVAL

AUTOMATIC SYNCHRONIZING SCHEMATIC DIAGRAM UNITS 1 THRU 4 - REMOVAL

EXCITATION SYSTEM RELAY OUTPUT STATUS - REMOVAL

EXCITATION SYSTEM REG. INPUT SIGNAL INTERFACE GEN. SHUTDOWN & INT. LIGHTING & REC. - REMOVAL

WIRING DIAGRAMS CONTROL SCHEMATIC DIAGRAM TRANSFORMER AUXILIARIES, SH. 1 - REMOVAL

WIRING DIAGRAMS CO2 SYSTEMS SCHEMATIC DIAGRAM - REMOVAL

EXCITATION SYSTEM EXCITER CONTROL DIAGRAM SHEET 1 - REMOVAL

UNIT AUXILIARY CONTROL DIAGRAMS SHEET 2 - REMOVAL

UNIT AUXILIARY CONTROL DIAGRAMS SHEET 1 - REMOVAL

UNIT 7 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNOR - REMOVAL

UNITS 5-8 CONTROL DIAGRAM, SHEET 4 VCB 524 - 824 - REMOVAL

UNIT 5 CONTROL DIAGRAM, SHEET 3 AUTO START STOP - REMOVAL

UNIT 5 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNOR - REMOVAL

UNITS 5 CONTROL DIAGRAM, SHEET 1 GENERATOR PROTECTIVE RELAYING - REMOVAL

UNITS 1-4 CONTROL DIAGRAMS, SHEET 4 VCB 124 - 424 - REMOVAL

UNIT 1 CONTROL DIAGRAM, SHEET 3 AUTO START STOP - REMOVAL

UNIT 1 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNORS - REMOVAL

UNITS 1-4, 6,7&8 CONTROL DIAGRAM, SHEET 1 PROTECTIVE RELAYING - REMOVAL

THREE LINE DIAGRAMS GROUND RELAYING & METERING PT'S - REMOVAL

THREE LINE DIAGRAMS GROUND RELAYING & METERING CT'S - REMOVAL

NOT USED

ONE LINE DIAGRAM SHEET 1 - REMOVAL

CONTROL ROOM INSTRUMENT & RELAY BOARD - REMOVAL

GOVERNOR NETWORK DIAGRAM - INSTALL

CABLE AND CONDUIT SCHEDULE - INSTALL

DIGITAL GOVERNOR CABINET TERMINAL CONNECTIONS - INSTALL

NOT USED

DIGITAL GOVERNOR CABINET OUTPUT RELAYS - INSTALL

UNIT CONTROL BOARD NO. 1 WIRING ACTUATOR PANEL - INSTALL

UNIT CONTROL BOARD NO. 1 WIRING INSTRUMENT PANEL - INSTALL

UNIT 1 WIRING DIAGRAMS GENERATOR, TURBINE & TRANSFORMER CONNECTION DIAGRAM - INSTALL

14.4KV GENERATOR SWITCHGEAR WIRING VCB 124 - INSTALL

NOT USED

RELAY BOARD WIRING PANEL 1RB - INSTALL

RELAY BOARD 11G1B WIRING PANEL 2RB, PARTIAL - INSTALL

RELAY BOARD 11G1A WIRING PANEL 2RB, PARTIAL - INSTALL

RELAY BOARD WIRING PANEL 2RB - INSTALL

INSTRUMENT BOARD REAR PANEL WIRING PANEL 2IBS - INSTALL

INSTRUMENT BOARD WIRING PANEL 2IB - INSTALL

AUTOMATIC SYNCHRONIZING SCHEMATIC DIAGRAMS UNITS 1 THRU 4 - INSTALL

NOT USED

NOT USED

WIRING DIAGRAMS CONTROL SCHEMATIC DIAGRAM TRANSFORMER AUXILIARIES, SH. 1 - INSTALL

WIRING DIAGRAMS CO2 SYSTEMS SCHEMATIC DIAGRAM - INSTALL

EXCITATION SYSTEM EXCITER CONTROL DIAGRAM SHEET 1 - INSTALL

UNIT AUXILIARY CONTROL DIAGRAMS SHEET 2 - INSTALL

UNIT AUXILIARY CONTROL DIAGRAMS SHEET 1 - INSTALL

NOT USED

NOT USED

NOT USED

NOT USED

NOT USED

UNITS 1-8 CONTROL DIAGRAMS, SHEET 4 VCB 124 - 824 - INSTALL

UNITS 1-8 CONTROL DIAGRAM, SHEET 3 DIGITAL GOVERNOR OUTPUT RELAYS- INSTALL

UNITS 1-8 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNORS - INSTALL

UNITS 1-8 CONTROL DIAGRAM, SHEET 1 PROTECTIVE RELAYING - INSTALL

THREE LINE DIAGRAMS GROUND RELAYING & METERING PT'S - INSTALL

THREE LINE DIAGRAMS GROUND RELAYING & METERING CT'S - INSTALL

NOT USED

ONE LINE DIAGRAM SHEET 1 - INSTALL

CONTROL ROOM INSTRUMENT & RELAY BOARD - INSTALL

CONTROL ROOM LAYOUT PARTIAL PLAN - EL. 1363.0 - INSTALL

INDEX OF CONTRACT DRAWINGS

NO.

SHEET TITLE

NO.

SHEET TITLE

GENERAL

MECHANICAL DEMOLITION

ELECTRICAL DEMOLITION

MECHANICAL INSTALLATION

ELECTRICAL INSTALLATION

FILE NO.FILE NAME FILE NAME FILE NO.

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

S I F

B B

P .0

G -0

X X

X .d g n

G

H D

C J L

R

IN

D E

X T

O D

R A

W

IN

G

G-002

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

E N

D D

A M

G

H D

C S

W H

:1

BBP-1.04-0/4

BBP-1.04-0/3

BBP-1.04-0/2

BBP-1.04-0/1

/0

/2

B B

P -1 .0

-0 /2

BBP-1.04-3-0/7

BBP-1.04-3-0/6

BBP-1.04-3-0/5

BBP-1.04-3-0/4

BBP-1.04-3-0/3

BBP-1.04-3-0/2

BBP-1.04-3-0/1

BBP-1.04-3-0/15

BBP-1.04-3-0/14

BBP-1.04-3-0/13

BBP-1.04-3-0/12

BBP-1.04-3-0/11

BBP-1.04-3-0/10

BBP-1.04-3-0/9

BBP-1.04-3-0/8

BBP-1.04-6-9A70/1

BBP-1.04-6-9A20/4

BBP-1.04-6-9A20/3

BBP-1.04-6-9E20/1

BBP-1.04-6-9A46/1

BBP-1.04-6-9A43/4

BBP-1.04-6-9A43/3

BBP-1.04-6-9A43/2

BBP-1.04-6-9A43/1

BBP-1.04-6-9A54/2

BBP-1.04-6-9A54/1

BBP-1.04-6-9A28/1

BBP-1.04-6-9A24/9

BBP-1.04-6-9A24/8

BBP-1.04-6-9A24/7

BBP-1.04-6-9A24/6

BBP-1.04-6-9A24/5

BBP-1.04-6-9A24/4

BBP-1.04-6-9A24/3

BBP-1.04-6-9H24/1

BBP-1.04-6-9A24/2

BBP-1.04-6-9G24/3

BBP-1.04-6-9G24/2

BBP-1.04-6-9G24/1

BBP-1.04-6-9E24/3

BBP-1.04-6-9E24/2

BBP-1.04-6-9E24/1

BBP-1.04-6-9A24/1

BBP-1.04-6-9A20/2

BBP-1.04-6-9A20/1

BBP-1.04-6-9A21/1

BBP-1.04-6-0A0/1

S T

E V

E N R

M

IL

E S P

E

L U

K E R

A Y

N O

R P

E

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

G-002SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:13:57 PM

MB-OPN83E564.1.dgn

MB-OPN83E563.dgn

MB-OPN83E562.dgn

MB-OPN83E561.dgn

MB-OPN83E560.dgn

7322-150105 SHEET 1 OF 1

5225-160225 SHEET 3 OF 17

5225-160225 SHEET 2 OF 17

5225-160225 SHEET 14 OF 17

5225-160225 SHEET 13 OF 17

5225-160225 SHEET 16 OF 17

MB-OPN83E1122_3.dgn

MB-OPN83E1121_6.dgn

5225-160225 SHEET 17 OF 17

5225-160225 SHEET 12 OF 17

MB-OPN83E323D.dgn

MB-OPN83E1831_5.dgn

MB-OPN83E931D_6.dgn

MB-OPN83E931C_7.dgn

MB-OPN83E932CG2_0.dgn

MB-OPN83E932CG1_0.dgn

MB-OPN83E932C_9.dgn

MB-OPN83E932B_4.dgn

MB-OPN83E932A_8.dgn

MB-OPN83E351_3.dgn

MB-OPN83E345I_3.dgn

MB-OPN83E345H.dgn

MB-OPN83E367.dgn

MB24-83E311_2.dgn

MB-OPN83E345F_1.dgn

MB-OPN83E321_4.dgn

MB-OPN83E320_5.dgn

MB-OPN83E317A_6.dgn

MB-OPN83E315C_7.dgn

MB-OPN83E315B_6.dgn

MB-OPN83E315A_5.dgn

MB-OPN83E315_5.dgn

MB-OPN83E311C_7.dgn

MB-OPN83E311B_6.dgn

MB-OPN83E311A_5.dgn

MB-OPN83E311_6.dgn

MB-OPN83E396_1.dgn

MB-OPN83E395_6.dgn

MB-OPN83E301_5.dgn

MB-OPN83E902.4

MB-OPN84E122.2

CABLE TRAYS GENERATOR BAY PLAN EL. 1363.0

CABLE TRAYS CABLE GALLERY - BAYS 5 THRU 8 PLAN EL. 1352.0

CABLE TRAYS CABLE GALLERY - BAYS 1 TRHU 4 PLAN EL. 1352.0

CABLE TRAYS SECTIONS AND DETAILS

CABLE TRAYS SPREADER ROOM & BAY 3 PLAN EL. 1342.0

COMMUNICATIONS ARCHITECTURE DIAGRAM USACE WNO GOVERNOR RETROFITS

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

UNIT CONTROL BOARD NO. 1 WIRING ACTUATOR PANEL

UNIT CONTROL BOARD NO. 1 WIRING INSTRUMENT PANEL

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

WIRING DIAGRAM - FRANCIS USACE NOW GOVERNOR RETROFITS

UNIT 1 WIRING DIAGRAMS GENERATOR, TURBINE & TRANSFORMER CONNECTION DIAGRAM

14.4KV GENERATOR SITCHGEAR WIRING VCB 124

RELAY BOARD REAR PANEL WIRING PANEL 1RBS

RELAY BOARD WIRING PANEL 1RB

RELAY BOARD 11G1B WIRING PANEL 2RB, PARTIAL

RELAY BOARD 11G1A WIRING PANEL 2RB, PARTIAL

RELAY BOARD WIRING PANEL 2RB

INSTRUMENT BOARD REAR PANEL WIRING PANEL 2IBS

INSTRUMENT BOARD WIRING PANEL 2IB

AUTOMATIC SYNCHRONIZING SCHEMATIC DIAGRAMS UNITS 1 THRU 4

RELAY OUTPUT STATUS

REG. INPUT SIGNAL INTERFACE GEN. SHUTDOWN & INT. LIGHTING & REC.

WIRING DIAGRMS CONTROL SCHEMATIC DIAGRAMS TRANSFORMER AUXILIARIES, SH. 1

WIRING DIAGRAMS CO2 SYSTEMS SCHEMATIC DIAGRM

EXCITATION SYSTEM EXCITER CONTROL DIAGRAM SHEET 1

UNIT AUXILIARY CONTROL DIAGRAMS SHEET 2

UNIT AUXILIARY CONTROL DIAGRAMS SHEET 1

UNIT 7 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNOR

UNITS 5-8 CONTROL DIAGRAM, SHEET 4 VCB 524 - 824

UNIT 5 CONTROL DIAGRAMS, SHEET 3 AUTO START STOP

UNIT 5 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNOR

UNITS 5 CONTROL DIAGRAMS, SHEET 1 GENERATOR PROTECTIVE RELAYING

UNITS 1-4 CONTROL DIAGRAM, SHEET 4 VCB 124 - 424

UNIT 1 CONTROL DIAGRAMS, SHEET 3 AUTO START STOP

UNIT 1 CONTROL DIAGRAM, SHEET 2 TURBINE AND GOVERNORS

UNITS 1-4, 6,7&8 CONTROL DIAGRAMS, SHEET 1 PROTECTIVE RELAYING

WIRING DIAGRAMS THREE LINE DIAGRAM SECONDARY POTENTIAL CIRCUITS - SH 1

WIRING DIAGRAMS THREE LINE DIAGRAM CT WIRING - SHEET 1

ONE LINE DIAGRAM SHEET 1

INSTRUMENT BOARD ASSEMBLY

POWER PLANT GENERATOR BAYS 4,5,& 6 PARTIAL PLAN-EL. 1363.0

B-81255-00-02

B-37030-00-06

A-81093-00-05

A-37030-00-07

A-37030-00-01

A-37030-66-01

MB15-87E119.2

RESTORING CABLE TELESCOPIC GUIDE PIN TYPE

P.M.G. DRIVE SUB-ASSEMBLY

ASSEMBLY OF GATE RELAY VALVE SIZE - 8"

GOVERNOR GENERATOR UNIT ASSEMBLY 20" HOUSING

OUTLINE OF GOVERNOR CABINET FOR BIG BEND

GATE SERVOMOTOR OIL PRESSURE PIPING ARRANGEMENT

PIPING - TURBINE GOVERNORS

E V

E N R

M

IL

E S P

E

A N

S I F

W F -1

-R -0

P .0

G -0

X X

X .d g n

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

T G

H

D C J L

R

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

B

IG

B

E N

D D

A M

G-003

IN

D

E X T

O R

E F

E R

E N

C E D

R A

W

IN

G S

L U

K E R

A Y

N O

R

TITLEFILE NO.

INDEX OF REFERENCE DRAWINGS

TITLEFILE NO.

G

H D

C S

W H

:1

MECHANICAL REFERENCE

ELECTRICAL REFERENCE

/0

/2

B B

P -1 .0

-0 /3

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

G-003SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:14:09 PM

GENERAL REMOVAL NOTES:

GENERAL INSTALL NOTES:

FURNISHED.

ALL OTHER EQUIPMENT IDENTIFIED AS NEW SHALL BE INSTALL CONTRACTOR

SYMBOL INDICATES ITEMS SUPPLIED AS GOVERNMENT FURNISHED EQUIPMENT.

7. PAINT ALL ITEMS PER SECTION 09 90 00.00 26.

INSTALLATION DETAILS PER SECTION 48 19 00.00 26.

TO FACILITATE A BETTER INSTALLATION. SUBMIT PRESSURE PIPE ROUTING AND

BE THE MOST PRACTICABLE ROUTING. SLIGHT MODIFICATION MAY BE ALLOWED

6. NEW PRESSURE PIPE ROUTING SHOWN ON THE INSTALL DRAWINGS MAY NOT

DRAWING SHALL GOVERN.

DIFFERS FROM THIS DRAWING, THE INFORMATION ON THE INDIVIDUAL

DEVICE NUMBERS AND LEGEND APPEAR ON AN INDIVIDUAL DRAWING AND

THIS DRAWING ARE APPLICABLE FOR ALL DRAWINGS. HOWEVER, IF SYMBOLS,

5. HYDRAULIC SCHEMATIC SYMBOLS, DEVICE NUMBERS AND LEGEND SHOWN ON

4. SEE SPECIFICATION SECTION 48 19 00.00 26 FOR DETAILS OF INSTALLATION.

FOR CLARITY AND/OR MAY NOT BE TO SCALE.

3. SOME COMPONENTS AND FEATURES ON THE FOLLOWING DRAWINGS ARE OMITTED

ON THE FOLLOWING INDIVIDUAL MECHANICAL DRAWINGS.

2. NOT ALL SYMBOLS SHOWN ON THIS DRAWING ARE REFERENCED

INDICATED BY HEAVIER WEIGHT LINES OR TEXT AS NOTED.

1. ON "M-###" SHEETS, NEW EQUIPMENT TO BE INSTALLED OR PROVIDED IS

FOR DETAILS OF HYDRAULIC-MECHANICAL GOVERNOR EQUIPMENT REMOVAL.

3. SEE SPECIFICATION SECTION 02 41 19.00 26 AND INSTALL TASK ORDER

FOR CLARITY.

2. SOME COMPONENTS AND FEATURES ON THE REMOVAL DRAWINGS ARE OMITTED

INDICATED BY HEAVIER LINE WEIGHTS,CLOUDING,TEXT AND/OR AS NOTED.

1. ON "MD###" SHEETS, EXISTING EQUIPMENT TO BE REMOVED IS

E V

E N R

M

IL

E S P

E

A N

S I E

/0

/2

G

H D

C S

W H

M E

C H

A N

IC

A L

:1

W F -1

-R -0

B B

P -1 .0

-0 /4

B B

P .0

G -0

X X

X .d g n

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

G

H D

C E

V H

D

IG

IT

A L G

O V

E R

N O

R U

P G

R A

D E

P O

W E

R H

O U

S E

C O

L U

M B

IA

R

IV

E R

B

IG

B

E N

D D

A M

G-004

B R

IA

N B

E L L

AC

CYLINDER, DOUBLE ACTING

CONTROL, SPRING

CYLINDER, SINGLE ACTING

CONTROL, LEVER

CONTROL, PEDAL

CONTROL, MANUAL

CONTROL, PUSHBUTTON

CONTROL, DETENT

COOLER, LIQUID COOLED

COOLER

BULKHEAD CONNECTION

PILOT CONTROLLED OPENING

PILOT CONTROLLED CLOSING

CHECK VALVE

CHECK VALVE

CHECK VALVE

SPRING LOADED

CARTRIDGE VALVE

CHECK VALVE

FIXED DISPLACEMENT

AIR COMPRESSOR

ACCUMULATOR

LINE, FLEXIBLE

HEATER

FILTER WITH BYPASS

ELECTRIC LINE

ELECTRIC MOTOR

FILTER OR DIFFUSER

SHUT-OFF VALVE, NORMALLY OPEN

SHUT-OFF VALVE, NORMALLY CLOSED

SHUTTLE VALVE

QUICK DISCONNECT COUPLING

PROPORTIONAL VALVE

PUMP, VARIABLE DISPLACEMENT

PUMP, FIXED DISPLACEMENT

PUMP, HAND OPERATED

PRESSURE SOURCE

PLUGGED PORT

MEASUREMENT, FLOW SHUT-OFF VALVE, 3-WAY

SNUBBER

FLOAT VALVE

PRESSURE TRANSDUCER

PRESSURE

MEASUREMENT,

TEMPERATURE

MEASUREMENT,

ADJUSTABLE

PRESSURE SWITCH

VALVE ADJUSTABLE

PRESSURE REDUCING

VALVE ADJUSTABLE

PRESSURE RELIEF

GOVERNOR PRESSURE TANK

2-WAY, 2-POSITION

DIRECTIONAL CONTROL VALVE

3-WAY, 2-POSITION

DIRECTIONAL CONTROL VALVE

3-WAY, 3-POSITION

DIRECTIONAL CONTROL VALVE

4-WAY, 2-POSITION

DIRECTIONAL CONTROL VALVE

4-WAY, 3-POSITION

DIRECTIONAL CONTROL VALVE

INDICATOR

FILTER WITH PLUGGED

INDICATORS

ELECTRICAL CLOGGING

FILTER WITH VISUAL AND

ADJUSTABLE

FLOW CONTROL VALVE,

ADJUSTABLE WITH BYPASS

FLOW CONTROL VALVE

ELECTRICAL SOLENOID

CONTROL,

MATERIAL INDICATIONS

EXISTING CONCRETE

GRAPHIC SYMBOLS LEGEND SECTION SYMBOLS

SECTION

VIEW

SHEET WHERE THE SECTION OR DETAIL IS TAKEN

THE SECTION OR DETAIL APPEARS ON THE SAME

BOTTOM HALF OF SYMBOL IS LEFT BLANK WHEN

IDENTIFICATION NUMBER

SECTION OR DETAIL

SECTION OR DETAIL IS DRAWN

PLATE NUMBER ON WHICH

SECTION OR DETAIL IS TAKEN

PLATE NUMBER ON WHICH

M E

C H

A N

IC

A L G

E N

E R

A L N

O T

E S

A N

D L

E G

E N

D

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

M-105

A

M-506

SECTION

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

G-004SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 11:09:43 AM

"2 12'-6

12'-10"8'-2"

"16 91'-11

P

IT

L

IN

E R

R

OPENING PORT

CLOSE

R.H. SERVOMOTOR

CLOSING PORT

U N

IT

UNIT

L.H. SERVOMOTOR

OPENING PORT

8" PRESSURE TO OPEN

TO CLOSE

8" PRESSURE

GOV. CABINET

"4 112'-1

"8 55'-10

PORT

CLOSING

CLOSE

"4 112'-1

NOTES:

REFERENCE DRAWINGS:

9'-6" 22'-6"

RESTORING CABLE TELESCOPE GUIDE

RESTORING CABLE CONN.

"16

SHEAVE, (TYP.)

RESTORING CABLE

1" RESTORING CABLE CONDUIT

FOR RE INSTALLATION

RETAIN NUT AND STUD

TO THE SPECIFICATIONS.

FOR WELDED MOUNTS, CUT FLUSH, GRIND SMOOTH, AND TOUCH UP PAINT ACCORDING

CABLE, SHEAVES, AND MOUNTING HARDWARE COMPLETELY, INCLUDING FASTENERS.

3. CONTRACTOR TO REMOVE ALL RESTORING CABLE COMPONENTS, TO INCLUDE CONDUIT,

2. DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

1. SEE GENERAL NOTES ON G-004.

B-81255-00-02

PIPING - TURBINE GOVERNORSMB15-87E119.2

ARRANGEMENT

GATE SERVOMOTOR OIL PRESSURE PIPING A-37030-66-01

RESTORING CABLE TELESCOPIC GUIDE PIN TYPE

PRESSURE TANK

PIPING TO

RETAIN THIS CONDUIT SUPPORT

/0

/2

B R

IA

N B

E L L P

E

B B

P -1 .0

-3 -0 /1

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

B B

P .0

M D

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

R E

M O

V A

L C

A B

L E P

L A

N V

IE

W

G A

T E R

E S

T O

R

IN

G

MD101

:1

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

E N

D D

A M

" = 1'-0"2

1SCALE:

PLAN VIEW

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

MD101SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 11:09:53 AM

EL. 1363.0'

EL. 1353.25'

RESTORING CABLE

EL. 1361.58'

NOTES:

REFERENCE DRAWINGS:

GOVERNOR CABINET

1" RESTORING CABLE CONDUIT

ACCORDING TO THE SPECIFICATIONS.

MOUNTS, CUT FLUSH, GRIND SMOOTH, AND TOUCH UP PAINT

HARDWARE COMPLETELY, INCLUDING FASTENERS. FOR WELDED

TO INCLUDE CONDUIT, CABLE, SHEAVES, AND MOUNTING

3. CONTRACTOR TO REMOVE ALL RESTORING CABLE COMPONENTS,

2. DIMENSIONS SHOWN ARE FOR REFERENCE ONLY.

1. SEE GENERAL NOTES ON G-004.

B-81255-00-02

PIPING - TURBINE GOVERNORSMB15-87E119.2

ARRANGEMENT

GATE SERVOMOTOR OIL PRESSURE PIPINGA-37030-66-01

RESTORING CABLE TELESCOPIC GUIDE PIN TYPE

RESTORING CABLE SHEAVE, TYP. RESTORING CABLE PIPE SUPPORT, TYP.

RETAIN THIS PIPE SUPPORT

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

B B

P .0

M D

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

R E

M O

V A

L

MD201

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B

E N

D D

A M

B R

IA

N B

E L L P

E

C A

B L E E

L E

V A

T

IO

T

E R

E S

T O

R

IN

G

/0

/2

B B

P -1 .0

-3 -0

/2SCALE: 1"=1'-0"

ELEVATION VIEW

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

MD201SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:14:42 PM

25242322

26 27 28 29 19

4 2 5

333231

4039383735

1211 13

W

R G RG

R

R

G A

G RAG R

BG R

BG R

BG R

9'-6" MAX.

6" "2

ACTUATOR SECTIONGAUGE AND INSTRUMENT SECTION

CABLE TRAY ADAPTER

WIRING DUCT

EMERG. LIGHT, 60W. INCAN., (TYP.)

EL. 1363.0

FINISHED FLOOR

NOTES:

REFERENCE DRAWINGS:

INSTRUMENTS & CONTROLS ON GOVERNOR CABINET

DESCRIPTIONITEM

2 TACHOMETER

FLUOR. LIGHTING FIXTURE, HOLOPHANE #9012-4-NL

5 GOVERNOR OIL PRESSURE GAUGE

PRESSURE TANK OIL LEVEL INDICATOR

TRANSFER VALVE POSITION INDICATOR

AIR BRAKE DUPLEX PRESSURE GAUGE

GATE LIMIT AND GATE POSITION INDICATOR

SPEED DROOP INDICATOR

11 SPEED DROOP CONTROL

SPEED ADJUSTMENT INDICATOR

SPEED ADJUSTMENT CONTROL

GATE LIMIT CONTROL

15 AIR BRAKE CONTROL

17 ACTUATOR SECTION LIGHT SWITCH

TRANSFER VALVE CONTROL

19 CO BREAK GLASS STATION

ELECTRIC CLOCK

21 ANNUNCIATOR PANEL

TELEPHONE

23 GENERATOR GUIDE BRG. TEMP. INDICATOR

GENERATOR THRUST BRG. TEMP. INDICATOR

25 TURBINE BEARING OIL TEMP. INDICATOR

TURBINE BEARING TEMPERATURE INDICATOR

27 DRAFT TUBE VACUUM GAUGE

GENERATOR THRUST BRG. OIL TEMP. INDICATOR

29 TURBINE BEARING OIL PRESSURE GAUGE

SPIRAL CASE PRESSURE GAUGE

31 CO DELAYED BANK CUTOUT CONTROL SWITCH

CANOPY LIGHT SWITCH

33 ANNUNCIATOR TEST AND RESET SWITCH

INTAKE GATES EMERG. LOWER CONTROL SWITCH

35 GENERATOR THRUST BRG. H.P. LUB. OIL PUMP CONTROL SW.

HORN CUTOUT SWITCH

37 GENERATOR SPACE HEATERS CONTROL SWITCH

GENERATOR THRUST BRG. OIL PRESS. IND. LIGHT

39 UNIT COOLING WATER VALVE CONTROL SWITCH

DRAFT TUBE WATER DEPRESSOR VALVES CONTROL SW.

41 ANNUNCIATOR RELAY CABINET (BEHIND PANEL)

TURBINE BRG. OIL PUMPS CONTROL SWITCH

43 GOVERNOR MOTOR CONTACTOR

GAUGE AND INSTRUMENT SECTION LIGHT SWITCH

45 AUXILIARY RELAY 4B, 6 CONTACTS

AUXILIARY RELAY 4A, 6 CONTACTS

47 AUXILIARY RELAY 20DY, 2 CONTACTS

AUXILIARY RELAY 20DX1, 2 CONTACTS

49 AUXILIARY RELAY 63X, 6 CONTACTS

AUXILIARY RELAY 63BPX, 6 CONTACTS

51 TIME DELAY RELAY 65MSY

TIME DELAY RELAY 65MSX

52 AUXILIARY RELAY 20DX2, 2 CONTACTS

3'-2"

"ITEM 1, (TYP.)

54 SHEAR PIN ANNUNCIATOR SWITCH

AUXILIARY RELAY 63X, RESEAL IN

R

G

WIRING DUCTS

MANUAL SHUTDOWN AND RESET P.B.

G

SWING PANEL

COLUMN

CONTROL

DETAIL SEE M-211

REINSTALLATION

AND LIGHT. FOR

RETAIN SWITCH

REMOVE AND

M A

X

3 NOT USED

REMOVABLE PANELS

SEE M-211

FOR RELOCATION.

TO BE RETAINED

48 19 00.00 26, DRAWING MD901, AND DRAWING M-111 FOR FURTHER DETAIL.

THAT THEY ARE READILY ACCESSIBLE FOR CALIBRATION PURPOSES. SEE SECTION

CONTRACTOR TO RELOCATE SWITCHES INSIDE GOVERNOR CABINET SUCH

TO BE REMOVED FROM EXISTING LOCATION, BUT RETAINED.

AND EXISTING BRAKE AIR PRESSURE SWITCHES (2),

2. EXISTING OIL PRESSURE SWITCHES (3),

1. SEE GENERAL NOTES ON G-004.

OUTLINE OF GOVERNOR CABINET FOR BIG BENDA-37030-00-01

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

B B

P .0

M D

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

R E

M O

V A

L

MD211

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B B

P -1 .0

-3 -0 /3

B

IG

B

E N

D D

A M

B R

IA

N B

E L L

C

T U

A T

O R C

A B

IN

E T E

L E

V A

T

IO

N

G O

V E

R N

O R

/0

/2

" = 1'-0"2

1SCALE: 1

ELEVATION

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

MD211SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:14:53 PM

NOTES:

DOME LIGHT

TERMINAL BLOCK COMPARTMENT

"O.D.8

SHAFT

ROTOR AND

REMAIN

GEAR TO

DRIVE

MAIN

SLEEVE

SLIDING

DISASSEMBLY

EXERCISE CAUTION DURING

BEHIND TERMINAL BLOCKS.

REMOVE THE SET SCREW

IN ORDER TO ACCESS AND

REMOVE TERMINAL BLOCKS

CONTRACTOR MAY NEED TO

IS NOT EASILY REMOVED,

NOTE: IF STATOR HOUSING

ELECTRICAL ENCLOSURE.

DRIVE SHAFT

ROTOR WINDINGS

STATOR WINDINGS, (TYP.)

MECHANICAL OVERSPEED SWITCH TO REMAIN

SPEED SWITCHES

20" O.D.

PROVIDED BY THE GOVERNMENT.

NUMBER 3700-100908 "TYPICAL INSTALLATION PLAN", TO BE

COMPONENTS AGAINST AMERICAN GOVERNOR COMPANY DOCUMENT

2. CONTRACTOR TO VERIFY REMOVAL/RETROFIT OF PMG

1. GENERAL NOTES ON G-004.

SEE DRAWING M-501

GFE PMG RETROFIT KIT

AND BUSHINGS FROM

REPLACED WITH NEW BEARINGS

TO BE REMOVED AND LATER

BEARINGS AND BUSHINGS

REFERENCE DRAWINGS:

GOVERNOR GENERATOR UNIT ASSEMBLY 20" HOUSINGA-37030-00-07

P.M.G. DRIVE SUB-ASSEMBLYA-37030-00-06

/0

/2

B B

P .0

M D

X X

X .d g n

G

H D

C S

W H

:1

W F -1

-R -0

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

O N

H Y

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

IC

T

S T

E V

E N R

M

IL

E S P

E

A N

S I F

G

H D

C J L

R

R E

M O

V A

L

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

B

IG

B

E N

D D

A M

B R

IA

N B

E L L P

MD501

M

G R

E T

R O

F

IT

D

E T

A

IL

B B

P -1 .0

-3 -0 /4

PMG ASSEMBLY

A

SCALE: 3" = 1'-0"

SECTION

A

NTS

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

MD501SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 8:44:31 AM

R

A

IN

SPEED DROOP

SPEED CHANGER

100%

2 3

5 0

GATE POSITION GATE LIMIT

(P)(L)

O P

E N

C L

O S

E

OPEN GATES

DRAIN

DRAIN

TANK

PRESSURE

SET

PUMPING

SUMP

ASSEMBLY

WEIGHT

FLYBALL

MOTOR

DRAIN

DRAIN

PRESSURE SUPPPLY

PRESSURE TO CLOSE

TO OPEN

PRESSURE

SHAFT

TURBINE

UNIT

GENERATOR

E

S

AERCNI

D

E

EPS

E T

A G S

N E

P O

E T

A G

S N

E P

O

VALVE

NEEDLE

GOVERNOR HEAD

MECHANISM

RESTORING

VALVE

AUXILLIARY

PILOT VALVE

PILOT VALVE CAGE

MECHANISM

SPEED DROOP

SHUT DOWN SOLENOID

DASHPOT

VALVE

TRANSFER

DRAIN

FILTERS

RESTORING CABLE

S N

E P

O

VALVE

LIMIT

GATE

GATE SERVOMOTOR

CONTROLET

PISTON

PILOT

STEM

VALVE

DISTRIBUTING

SPOOL

2. COMPONENTS ARE MARKED FOR REMOVAL IN ONE VIEW ONLY.

1. SEE GENERAL NOTES ON G-004.

REFERENCE DRAWINGS

ASSEMBLY OF GATE RELAY VALVE SIZE - 8"A-81093-00-05

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

B R

A S

K A

O M

A H

A D

IS

T R

E V

E N R

M

IL

E S P

E

A N

S I F

/0

/2

B B

P .0

M D

X X

X .d g n

G

H D

C J L

R G

H

D C

S W

H

R E

M O

V A

L

MD601

:1

D

IG

IT

A L G

O V

E R

N O

R I

N S

T A

L L

P O

W E

R H

O U

S E

M

IS

S O

U R I

R

IV

E R

W F -1

-R -0

B B

P -1 .0

-3 -0 /5

B

IG

B

E N

D D

A M

B R

IA

N B

E L L

V

E R

N O

R

H Y

D R

A U

L

IC

D

IA

G R

A M

NTS

HYDRAULIC DIAGRAM

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/5 /2

BORDER VERSION UPDATE [09-2012]

MD601SHEET NAME:g2hdckri Kevin R. ImholtBY USERNAME:DATE AND TIME PLOTTED: 7/5/2016 2:15:16 PM

2. ELECTRICAL WIRING IS SHOWN ON DRAWING E-614

1. SEE GENERAL NOTES ON G-004.

GOV. AIR PRESSURE TANK PHOTO

EXISTING GEAR TO REMAIN

REMOVE SELSYN MOTOR

N.C., FOR AIR ADMISSION

90 DEGREE MANUAL BALL VALVE

N.C., FOR AIR ADMISSION

90 DEGREE MANUAL BALL VALVE

GOV. AIR PRESSURE TANK GOV. OIL ACCUMULATOR

GOVERNOR ACTUATOR CABINET

AIR COMPRESSORS

PRESSURIZED GOV. OIL TO ACTUATOR RESERVOIR

AIR ADMISSION CHECK VALVE

N.C., FOR CONDENSATE DRAIN

MANUAL GLOBE VALVE

/0

/2

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

P O

R T

L A

N D

O R

E G

D R

O E

L E

C T

R

IC

D

E S

IG

N C

E N

T E

R

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

E V

E N R

M

IL

E S P

E

A N

S I F

B B

P .0

M D

X X

X .d g n

G

H D

C J L

R

B R

IA

N B

E L L P

E G

H D

C S

W H

R E

M O

V A

L S

C H

E M

A T

IC

A U

T O

M A

T

IC

A

IR

B

A L

A N

C

IN

G

MD602

:1

IT

A L G

O V

E R

N O

R U

P G

R A

D E

P O

W E

R H

O U

S E

C O

L U

M B

IA

R

IV

E R

W F -1

-R -0

B B

P -1 .0

-3 -0 /6

B

IG

B

E N

D D

A M

AIR ADMISSION CHECK VALVE

O M

A H

A D

IS

T R

IC

T

O M

A H

A

N E

B R

A S

K A

DRAWING PLOT SIZE: ANSI F

D

C

A

B

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

IDENTIFICATION

SHEET

1 2 3 4 5 6

E

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E A

P P

R of Engineers

US Army Corps

/1

/2

BORDER VERSION UPDATE [09-2012]

MD602SHEET NAME:g2hdcjlr Jennifer L. RaetzBY USERNAME:DATE AND TIME PLOTTED: 8/16/2016 11:10:01 AM

File details come from the government source that posted it. Updated .