This federal contract opportunity announcement provides details for the FY21 Gymnasium Building 1795 Repairs project at Aliamanu Military Reservation in Oahu, Hawaii. The U.S. Army Corps of Engineers, Honolulu District intends to issue a sealed bid solicitation on or around June 7, 2021 via beta.SAM.gov for design-bid-build construction services. The project scope involves concrete spall repair, louver replacement, window repair and gym flooring patch repairs. The NAICS code is 236220 for commercial and institutional building construction, with a small business size standard of $39.5M average annual revenue. The government intends to award a firm fixed-price contract and will accept bids until approximately late July 2021. The estimated period of performance is 270 calendar days with a project magnitude between $500,000 to $1M, subject to availability of funds. The solicitation will be set aside for woman-owned small businesses.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C T

N

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W A

D

G

Y M

N A

S I U

M

B

U I L D

I N

G

R

E P

A I R

S

A L I A

M A

U

M

I L I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W A

D

A N

S I

D

C o S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I

U

S

A

O

T

T

R

J.

A

D

A

H

A

R

G-001

GYMNASIUM

(NIC)

LIBRARY

(NIC)

RECREATION CENTER

(NIC)

FY21 GYMNASIUM BUILDING 1795 REPAIRS

ALIAMANU MILITARY RESERVATION, OAHU, HAWAII

CONTRACT NO.: W9128A-19-D-0010

OAHU

KAHUKU POINT

CITY

PEARL

WAHIAWA

WAIANAE

WAIPAHU

NANAKULI

EWA

POINT

KAENA

HALEIWA

WAIMEA

KAILUA BAY

KANEOHE

HONOLULU

AIEA

KAAAWA

LAIE

PROJECT

LOCATION

PACIFIC OCEAN

OAHU MAP (NTS)

LOCATION MAP (NTS)

CONTRACTOR ACCESS ROUTE

PROJECT SUBMITTAL

DESIGN COMPLETE SUBMITTAL

6/1/2021

ARCHITECT:

INK ARCH, LLC

650 IWILEI ROAD, SUITE 288

HONOLULU, HI 96817

PH: (808) 536-1174

PROJECT TEAM

STRUCTURAL:

KAI HAWAII, INC

50 SOUTH BETERTANIA ST, C-119C

HONOLULU, HI 96813

PH: (808) 553-2210

PROJECT SCOPE

DEMOLISH LOUVERS ON EAST AND WEST SIDE, AS INDICATED

REFURBISH EXISTING SLIDING GLASS WINDOWS IN PLACE, AS INDICATED

DEMOLISH AND REPLACE JOINT SEALANT, AS INDICATED

PAINT ENTIRE EXTERIOR FACADE

PARTIAL CONCRETE SPALL AND CRACK REPAIRS, AS INDICATED

PARTIAL GYM FLOORING REPAIR, AS INDICATED

WORK INCLUDES BUT IS NOT LIMITED TO:

K

A

U

H

I

R

D

B

O

U

G

A

I

N

V

I

L

L

E

L

O

P

A

L

I

A

M

A

I

V

E

H

F

E

E

W

A

Y

AD101

A1

SITE PLAN (NTS)

COMMUNITY

CENTER

(NIC)

SITE LOCATION

BLDG 1795

GYM

PROPOSED CONTRACTOR PARKING (8) STALLS

P

A

R

K

I

T

A-101

A1

PROPOSED 10' X 20'

COSA

(CHAIN-LINK FENCE

W/ WEIGHTED

POSTS, NO GROUND

PENETRATIONS)

APPROXIMATE

LOCATION OF TREE

TRUNK

A

K

P

U

UNMANNED

GUARD SHACK

H

E

A

D

W

S

T

E

W

A

P R

O J E

T

L E

O

A H

U

M

A P

L O

C A

T I O

N

M

A P

S I T

E

P

L A

N

P

R O

J E

A

M

P

R O

J E

O

P E

P R

O J E

B

M I T

T A

L

TRUE

NORTH

TRUE

NORTH

TRUE

NORTH

E

A

S

T

APPROXIMATE

LOCATION OF

TEMPORARY

WALKWAY

ALTERNATE

ROUTE

APPROXIMATE

LOCATION OF

CONSTRUCTION

AREA BARRICADE

ALTERNATE

ROUTE

NOTE:

1. CONTRACTOR TO

COORDINATE WITH USER

THE FINAL LOCATIONS OF

THE CONSTRUCTION AREA

BARRICADE, AND

TEMPORARY WALKWAYS

FOR ALTERNATE ROUTES.

2. CONTRACTOR SHALL

CONTACT FED FIRE CHIEF

AMISONE

MONA.AMISONE@NAVY.MIL

PRIOR TO CONSTRUCTION

TO CONDUCT A SITE

INSPECTION.

ALIAMANU

MILITARY

RESERVATION

INDEX TO DRAWINGS

G-002

GENERAL NOTES

1. LAWS AND ORDINANCES: AS USED HEREIN SHALL MEAN ALL COUNTY, STATE AND NATIONAL

CODES, ORDINANCES, STANDARDS, RULES AND REGULATIONS OF ANY NATURE WHICH ARE

PERTINENT TO, OR REGULATORY OVER, THE WORK COVERED BY THE CONTRACT DOCUMENTS

OF THIS PROJECT. ALL CONTRACTORS SHALL COMPLY FULLY WITH ALL APPLICABLE LAWS AND

ORDINANCES. ALL CONSTRUCTION SHALL CONFORM TO THE CURRENT BUILDING CODE AND THE

LATEST BY EACH AGENCY HAVING JURISDICTION OF THE PROJECT.

2. CONFLICT: ANYTHING MENTIONED IN THE SPECIFICATIONS AND NOT SHOWN ON THE DRAWINGS, OR SHOWN ON THE DRAWINGS AND NOT MENTIONED IN THE SPECIFICATIONS SHALL BE OF LIKE

EFFECT AS IF SHOWN OR MENTIONED IN BOTH. IN CASE OF DISCREPANCY IN THE FIGURES, IN

THE DRAWINGS, OR IN THE SPECIFICATIONS, THE MATTER SHALL BE PROMPTLY SUBMITTED TO

THE CONTRACTING OFFICER, WHO SHALL PROMPTLY MAKE A DETERMINATION IN WRITING. ANY

ADJUSTMENT BY THE CONTRACTOR WITHOUT SUCH A DETERMINATION SHALL BE AT ITS OWN

RISK AND EXPENSE. (PER UFC 1-300-09N AND FAR 52.236-21)

3. CONDITIONS OF THE WORK: THE INFORMATION INDICATED ON THE DRAWINGS ARE BASED ON

LIMITED FIELD INVESTIGATIONS AND ON THE AVAILABLE RESOURCES AT THE TIME OF DOCUMENT

PREPARATION. AS A RESULT, THE ACCURACY AND COMPLETENESS OF THE INFORMATION IS NOT

GUARANTEED. THE CONTRACTOR SHALL, THEREFORE VERIFY THE DIMENSIONS SHOWN ON THE

DRAWINGS WITH ACTUAL FIELD MEASUREMENTS, EXAMINE THE JOB SITE, VERIFY ALL FIELD

CONDITIONS AND PROVIDE THE LABOR AND MATERIALS REQUIRED TO COMPLETE THE REQUIRED

WORK. ALL WORK SHALL BE PERFORMED IN A PROFESSIONAL MANNER THAT IS OF ACCEPTABLE

WORKMANSHIP OF THE RESPECTIVE TRADES. THE CONTRACTOR SHALL NOTIFY THE

CONTRACTING OFFICER, PRIOR TO THE COMMENCEMENT OF WORK, IF THERE ARE ANY

DIMENSIONAL DISCREPANCIES, OR IF THERE ARE ANY CONDITIONS THAT EXIST WHICH MAY

PREVENT THE CONTRACTOR'S PERFORMANCE OF WORK, AND/OR OF ANY AND ALL ADDITIONAL

WORK THAT MAY BE REQUIRED AS A RESULT OF THE OBSERVED CONDITIONS.

4. OMISSIONS: OMISSIONS OF THE DRAWINGS, OR SPECIFICATIONS, OR THE OMISSIONS OF

DETAILS OF WORK WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE

DRAWINGS AND SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT

RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED, OR INCORRECTLY DESCRIBED

DETAILS OF THE WORK, BUT SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH

AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS. THE CONTRACTOR SHALL NOTIFY THE

CONTRACTING OFFICER, VERBALLY OF SUCH OMISSIONS AND PROVIDE A WRITTEN STATEMENT

OF THE OMISSIONS WITHIN (5) WORKING DAYS OF VERBAL NOTIFICATION.

5. INTENT OF THE DRAWINGS: THE DRAWINGS ARE INTENDED TO DEFINE AND ESTABLISH THE

PHYSICAL REQUIREMENTS OF THE PROJECT, I.E., THE DESIGN, LOCATIONS AND DIMENSIONS OF

THE WORK, BASED ON RECOGNIZED STANDARDS, EVEN IF NOT ACTUALLY SHOWN, BUT

REASONABLY INFERRED. ALL WORK SHOWN IS "NEW" UNLESS OTHERWISE NOTED AS "EXISTING."

THE CONTRACTOR SHALL REVIEW AND VERIFY THE INFORMATION ON ALL DRAWINGS BEFORE

PERFORMING THE WORK AND NOTIFY THE CONTRACTING OFFICER, OF ANY DISCREPANCIES. THE

CONTRACTOR SHALL COORDINATE THE WORK OF ALL SUBCONTRACTORS/TRADES TO ACHIEVE

THE DESIGN INTENT AND SPECIFIED REQUIREMENTS AND IS RESPONSIBLE TO COMPLETE ANY

AND ALL WORK ASSOCIATED WITH SUCH COORDINATION.

6. COMPLETION OF THE WORK: THE CONTRACTOR SHALL IN THE WORK OF ALL TRADES, PERFORM

ANY AND ALL CUTTING, PATCHING, REPAIRING, RESTORING AND THE LIKE NECESSARY TO

COMPLETE THE WORK AND RESTORE ANY DAMAGED OR AFFECTED SURFACES RESULTING FROM

THE WORK OF THIS CONTRACT TO THEIR ORIGINAL CONDITION TO THE SATISFACTION OF THE

CONTRACTING OFFICER. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES OF CONSTRUCTION, INCLUDING, BUT NOT LIMITED

TO SAFETY PRECAUTION.

7. CLEAN UP: THE CONTRACTOR SHALL CLEAN AND REMOVE ANY TRASH, DIRT, DEBRIS AND

SPILLAGE ARISING FROM THE WORK DAILY, INCLUDING: CLEANING OF DIRT, PUTTY, PAINT, DUST, ETC. FROM AREAS, COUNTER TOPS, DOOR AND WINDOW FACES AND FRAMES.

8. DIMENSIONS: UNLESS OTHERWISE NOTED IN THE CONSTRUCTION DOCUMENTS, ALL

DIMENSIONS ARE TAKEN TO THE FACE OF EXISTING STRUCTURE, OR FACE OF CONSTRUCTION.

WRITTEN DIMENSIONS PREVAIL, DO NOT SCALE DRAWINGS. SHOULD DIMENSIONAL

DISCREPANCIES BE FOUND, CONTACT CONTRACTING OFFICER FOR CLARIFICATION PRIOR TO

PROCEEDING WITH THE WORK.

9. PREVENT DAMAGE: THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT

DAMAGE TO EXISTING AND COMPLETED STRUCTURES AND SHALL BE FULLY RESPONSIBLE FOR

ANY DAMAGE TO EXISTING STRUCTURES CAUSED BY HIS OPERATIONS.

10. DO NOT BLOCK EXITS: THE CONTRACTOR SHALL NOT BLOCK OR OBSTRUCT ANY EXIT WAYS

DURING THE EXECUTION OF WORK THROUGHOUT THIS PROJECT.

11. EXISTING UTILITIES: THE CONTRACTOR SHALL COORDINATE AND VERIFY THE LOCATIONS OF ALL

UNDERGROUND OR OVERHEAD UTILITY LINES TO AVOID CONFLICTS DURING ALL STAGES OF

CONSTRUCTION.

12. HAZARDOUS MATERIALS: THE GOVERNMENT WILL TEST ANY UNFORESEEN ASBESTOS

CONTAINING OR ANY OTHER HAZARDOUS MATERIAL ENCOUNTERED OR SUSPECTED, AND

DEPENDING ON THE RESULTS THE GOVERNMENT MAY ISSUE A MOD FOR ABATEMENT AND

DISPOSAL. BURNING OF ANY DEBRIS IS NOT PERMITTED. EXPLOSIVES ARE NOT ALLOWED.

HAZARDOUS MATERIAL SHALL BE ADDRESSED UNDER THIS WORK AND BASED ON THE SURVEY

RESULTS.

13. WOOD: ALL NEW WOOD SHALL BE TERMITE TREATED. ALL PAINT ON WOOD SURFACES SHALL

CONTAIN A MILDEWCIDE ADDITIVE.

14. DISSIMILAR METAL PROTECTION: THE CONTRACTOR SHALL PROVIDE DISSIMILAR METAL

PROTECTION.

15. SAFE OPERATIONS: THE CONTRACTOR SHALL ENSURE THAT ANY AND ALL CONSTRUCTION

ACTIVITIES DO NOT IMPACT OR INTERFERE WITH NORMAL OR SAFE OPERATIONS AT THE

PROJECT SITE.

16. RENOVATION WORK: THE CONTRACTOR SHALL PROPERLY SHORE BUILDING WALLS, CEILINGS

AND ANY OTHER COMPONENTS AFFECTED BY RENOVATION AS REQUIRED TO MAINTAIN A SAFE

AND STABLE STRUCTURE.

17. DEMOLITION WORK: MATERIALS RESULTING FROM THE DEMOLITION WORK SHALL BECOME THE

PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF IN ACCORDANCE WITH

APPLICABLE FEDERAL, STATE AND LOCAL LAWS, RULES AND REGULATIONS.

18. SOUND AND NOISE CONTROL: THE CONTRACTOR SHALL NOTIFY AND COORDINATE WITH THE

CONTRACTING OFFICER ALL WORK THAT WILL GENERATE EXCESSIVE NOISE WHICH MAY

DISRUPT THE FUNCTIONS OF ALL SURROUNDING ACTIVITIES, INCLUDING ADJACENT BUILDINGS.

19. DEFINITIONS: "FURNISH" MEANS "FURNISH ONLY". MATERIALS OR ITEMS TO BE FURNISHED

SHALL BE CONSIGNED TO THE CONTRACTOR AND DELIVERED TO THE SITE. "INSTALL" MEANS

"INSTALL ONLY" FURNISHED MATERIALS OR ITEMS. SUCH MATERIALS OR ITEMS SHALL BE

RECEIVED AT THE SITE, UNLOADED, STORED, PROTECTED, AND INSTALLED IN PLACE, INCLUDING

FINAL CONNECTION, UNLESS SUCH WORK IS SPECIFICALLY EXCLUDED. "PROVIDE" MEANS

"FURNISH AND INSTALL" COMPLETE, IN PLACE AND READY FOR USE, INCLUDING FINAL

CONNECTIONS. WORDS "CONTRACTOR SHALL" ARE IMPLIED AND SHALL BE SO UNDERSTOOD

WHEREVER A DIRECTION IS STATED IN IMPERATIVE MOOD AND DIRECTION "PROVIDE" IS USED.

UNLESS SPECIFICALLY STATED AS "EXISTING", ALL MATERIALS SHALL BE NEW IN ALL CASES

WHEN NOTES ARE ADDED TO DRAWINGS. ALSO, USES OF "FURNISH" AND "PROVIDE"

AUTOMATICALLY MEANS "NEW" UNLESS SPECIFICALLY STATED AS "EXISTING".

20. CONTRACTOR SAFETY: THE CONTRACTOR IS REQUIRED TO HAVE A WRITTEN COMPANY SAFETY

POLICY MANUAL AND SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL SAFETY LAWS AND

REGULATIONS GOVERNED UNDER THE EM385-1-1, (SAFETY AND HEALTH REQUIREMENTS

MANUAL). THE CONTRACTOR SHALL TAKE ALL NECESSARY AND PRUDENT PRECAUTIONS AND

SAFETY MEASURES WHEN WORKING ON ANY PORTIONS OF THE BUILDING IN ELEVATED OFF

GROUND/ FLOOR CONDITIONS.

21. USER SAFETY: THE CONTRACTOR SHALL NOTE THAT ADJACENT BUILDINGS WILL BE IN USE

DURING CONSTRUCTION. CONTRACTOR SHALL BARRICADE WORK AREAS PER SPECIFICATIONS

AND TAKE OTHER APPROPRIATE MEASURES AS REQUIRED BY THE USER TO PROTECT THE

USERS AND THE PUBLIC DURING CONSTRUCTION.

22. NOISE: THE CONTRACTOR WILL BE SUBJECT TO NOISE CONTROL REQUIREMENTS OF THE USER.

THESE REQUIREMENTS MAY AFFECT SCHEDULING AND WORK PERFORMANCE.

23. EXISTING SITE CONDITIONS AND EXISTING LANDSCAPING: THE CONTRACTOR SHALL FIELD

VERIFY ALL SITE CONDITIONS PRIOR TO BIDDING ON THE PROJECT, INCLUDING BUT NOT LIMITED

TO, THE EXISTING TOPOGRAPHY, TREES, SHRUBS, LANDSCAPING, AND OTHER CONDITIONS

SURROUNDING THE EXISTING BUILDING WHICH MAY AFFECT THE WORK. BASED UPON THE

EXISTING CONDITIONS, THE CONTRACTOR SHALL PROVIDE APPROPRIATE WORK METHODS.

EXISTING LANDSCAPING IS NOT SHOWN ON THE DRAWINGS.

24. REPAIR LANDSCAPING: THE CONTRACTOR, AT THEIR SOLE EXPENSE, SHALL REPAIR ALL

LANDSCAPING (INCLUDING SOIL, WALKWAYS, PAVEMENTS, AND CURBING) WHICH ARE DAMAGED

DURING THE WORK..

25. TREE PROTECTION ZONE FENCING: TREE PROTECTIVE ZONE FENCING AROUND EXISTING TREES

SHALL BE INSTALLED PRIOR TO COMMENCING CONSTRUCTION OPERATIONS. FENCING SHALL

CONSIST OF ORANGE COLORED PLASTIC FENCING MATERIAL AND SHALL BE FOUR-FEET HIGH.

SIX-FOOT METAL POSTS (DRIVEN TWO-FEET DEEP) SHALL BE EVENLY SPACED AT TEN-FEET O.C.

MAXIMUM. THE ORANGE PLASTIC FENCING MATERIAL SHALL BE SECURELY FASTENED TO THE

POSTS TO MINIMIZE SAGGING BETWEEN THE POSTS. ATTACH REQUIRED SIGNAGE TO FENCE

MATERIAL.

26. MULCH: INSTALL FOUR-INCH LAYER OF ORGANIC MULCH WITHIN TREE PROTECTION ZONE (TPZ).

NO HEAVY EQUIPMENT IS ALLOWED INSIDE TPZ. MULCH SHALL NOT EXCEED FOUR-INCH

PARTICLE SIZE.

27. LIMITATION OF CONSTRUCTION ACTIVITIES BENEATH TREE CROWN AND OUTSIDE OF THE TREE

PROTECTION ZONE FENCING: ALL CONTRACTORS SHALL LIMIT ACTIVITIES UNDER THE CROWN OF

TREES TO ONLY THOSE ACTIVITIES EXPLICITLY REQUIRED TO COMPLETE THE CONSTRUCTION

ACTIVITIES AS SPECIFIED UNDER AND/OR ADJACENT TO TREE CROWNS. MATERIAL STOCKPILING, VEHICLE PARKING, TEMPORARY ROADWAYS, CONSTRUCTION MATERIAL MIXING OR DUMPING, PORTABLE LATRINES AND FIELD OFFICES SHALL NOT BE TEMPORARILY OR PERMANENTLY

LOCATED UNDER TREE CROWNS EXCEPT IN AREAS WITH PRE-EXISTING PAVING AND/OR IN

AREAS SPECIFICALLY APPROVED BY THE CONTRACTING OFFICER.

28. FUGITIVE DUST: THE CONTRACTOR SHALL TAKE REASONABLE PRECAUTIONS TO MINIMIZE

FUGITIVE DUST GENERATED FROM CONSTRUCTION ACTIVITIES. PLEASE SEE HAWAII

ADMINISTRATIVE RULES 11-60.1-33, "FUGITIVE DUST" FOR A DESCRIPTION OF REASONABLE

PRECAUTIONS: HTTP://HEALTH.HAWAII.GOV/OPPPD/FILES/2015/06/11-60.1.PDF

29. PAINTING: IN THE EVENT CONDITIONS ARISE WHERE PAINTING SCOPE OF WORK IS NOT CLEARLY

DEFINED, THE GREATER QUALITY AND QUANTITY SHALL PREVAIL AND BE PROVIDED BY THE

CONTRACTOR AT NO ADDITIONAL COSTS. ALL EXPOSED STEEL, WHETHER LEFT EXPOSED

INTENTIONALLY OR UNINTENTIONALLY, WHETHER FACTORY PRIMED OR UN-PRIMED, SHALL BE

INSPECTED FOR RUST OR DAMAGES, AND SURFACE PREPARED (PER PAINT MANUFACTURER'S

RECOMMENDATIONS), AND SHALL BE TREATED WITH A COMMERCIAL GRADE RUST INHIBITOR.

THE FINISH PAINTING OF THESE SURFACES SHALL BE PER SPECIFICATIONS. SHOULD THE

CONTRACTOR DISCOVER UNDERLYING AND EXTENSIVE DAMAGE SURFACES, THE CONTRACTOR

SHALL IMMEDIATELY DOCUMENT AND SUBMIT IN WRITING, A REQUEST FOR INFORMATION ("RFI")

FOR FURTHER DIRECTIONS PRIOR TO PROCEEDING IN THE AFFECTED AREA.

30. EXTERIOR UPPER ROOF CEILING PANELS: SHOULD THE CONTRACTOR DISCOVER WARPED,

MISSING, AND/OR LOOSE CEILING PANELS, THE CONTRACTOR SHALL IMMEDIATELY DOCUMENT

AND INFORM THE GOVERNMENT OF THE CONDITION.

ARCHITECTURAL SYMBOLS

DETAIL REFERENCING

DRAWING NUMBER

SHEET NUMBER

SECTION REFERENCING

DRAWING NUMBER

SHEET NUMBER

TITLE

SCALE: 1/4" = 1'-0"

A

A-

DRAWING TITLE

A-

GRID IDENTIFIER

(HORIZONTAL)

GRID IDENTIFIER

(VERTICAL)

WINDOW IDENTIFICATION

NUMBER

A

L

LOUVER IDENTIFICATION

NUMBER

A-

ABV ABOVE

ALUM ALUMINUM

BLDG BUILDING

COL COLUMN

CONC CONCRETE

COSA CONSTRUCTION OFFICE

STORAGE AREA

DEMO DEMOLISH/

DEMOLITION

DS DOWNSPOUT

DWG DRAWING

ELEC ELECTRICAL

INFO INFORMATION

MET METAL

NIC NOT IN CONTRACT

NTS NOT TO SCALE

PLYWD PLYWOOD

RCP REFLECTED CEILING

PLAN

RD ROAD

RO ROUGH OPENING

SCHED SCHEDULE

SF/SQ FT SQUARE FEET

SHT(S) SHEET(S)

STRUCT STRUCTURAL

TYP TYPICAL

UON UNLESS OTHERWISE

NOTED

# NUMBER; POUND

& AND

ARCHITECTURAL ABBREVIATIONS

GENERAL

SHEET

NO. SHEET ID. SHEET TITLE

GENERAL

1 G-001 PROJECT TITLE, OAHU MAP, LOCATION MAP, SITE PLAN, PROJECT TEAM, PROJECT SCOPE, PROJECT

SUBMITTAL

2 G-002 GENERAL NOTES, INDEX TO DRAWINGS, ARCHITECTURAL ABBREVIATIONS, SYMBOLS

STRUCTURAL

SHEET

NO. SHEET ID. SHEET TITLE

3 S-001 GENERAL NOTES, REPAIR SCHEDULE, TYPICAL REPAIR DETAILS

4 S-201 REPAIR ELEVATIONS

ARCHITECTURAL

SHEET

NO. SHEET ID. SHEET TITLE

5 AD101 DEMOLITION FLOOR PLAN

6 AD201 DEMOLITION EXTERIOR ELEVATIONS

7 AD901 EXISTING REFERENCE PHOTOS

8 A-101 FLOOR PLAN

9 A-102 REFLECTED CEILING PLAN AND UPPER ROOF REFLECTED CEILING PLAN

10 A-201 EXTERIOR ELEVATIONS

11 A-202 INTERIOR ELEVATIONS

12 A-601 LOUVER SCHEDULE AND TYPES, WINDOW SCHEDULE AND TYPES, FINISH AND MATERIAL SCHEDULE

13 A-602 LOUVER DETAILS, WINDOW DETAILS, MISCELLANEOUS DETAILS

G E

N E

R A

L

N

O T

E S

I N

D E

X

T

O

D

R A

W I N

G S

A R

C H

I T

E C

T U

R A

L

A

B B

R E

V I A

T I O

N S

S

Y M

B O

L S

NORTH ARROW

PLAN

NORTH

T

R

XXX

ROOM IDENTIFICATION

XX

MATERIAL FINISH

TAG

ROOM NAME

ROOM NUMBER

(SEE MATERIAL FINISH

SCHEDULE, FOR ADDITIONAL

INFORMATION)

(SEE WINDOW

SCHEDULE, FOR

ADDITIONAL

INFORMATION)

(SEE LOUVER SCHEDULE,

FOR ADDITIONAL

INFORMATION)

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

DETAIL

REPAIR SCHEDULE

DESCRIPTION

A3/S-001

A3/S-001

REPAIR MARK AND ESTIMATED QUANTITIES

CRACK GREATER THAN

0.010" AND LESS THAN

0.125" (L.F.)

CRACK GREATER THAN

OR EQUAL TO 0.125" (L.F.)

R1

NOTES:

1. REPAIR SHALL BE SQUARE OR RECTANGULAR IN SHAPE. DO NOT

DAMAGE REINFORCING STEEL WHEN SAWCUTTING.

2. CONCRETE SURFACE TO RECEIVE REPAIR MORTAR SHALL BE

ROUGHENED TO 18" AMPLITUDE.

3. CLEAN EXPOSED REINFORCING BY HAND OR WITH POWER TOOLS SO IT IS

FREE OF LOOSE RUST AND OTHER LAITANCE PER SSPC-SP2 OR

SSPC-SP3.

4. COAT EXPOSED REINFORCING WITH 2 COATS OF BONDING AGENT. EACH

COAT SHALL BE 20 MILS THICK.

5. COAT CONCRETE SURFACE WITH 20 MIL THICK BONDING AGENT.

SURFACE SHALL BE SATURATED SURFACE DRY (SSD) AND CLEANED FREE

OF LAITANCE, DUST AND OTHER BOND INHIBITNG MATERIAL.

6. THICKNESS OF LAYERS OF REPAIR MORTAR SHALL BE AS LIMITED BY THE

MANUFACTURER. SCRATCH SURFACE OF INTERMEDIATE LAYERS TO

RECEIVE ADDITIONAL LAYERS.

7. REPAIR AREA SHALL BE CURED A MINIMUM OF 14 DAYS BEFORE THE

SURFACE IS PRIMED AND PAINTED.

CONCRETE

SURFACE

OUTLINE OF

CONCRETE SPALL

1" MIN ALL

AROUND

EXISTING

REINFORCING

STEEL

SURFACE PROFILE

P A

T C

H

IN

G M

A T

E R

IA

L L

IM

IT

S

E X

IS

T

IN

G

H O

L L O

W

S O

U N

D

IN

G L

IM

IT

S

LIMITS OF

EXISTING

SPALL OR

DELAMINATION

4" MIN ANNULAR

SPACE BEHIND

EXISTING

REBARS,

TYP

4"

SECTION

SAWCUT 12" DEEP, MIN

AND CHIP AWAY

CONCRETE TO SOUND

SUBSTRATE. PROVIDE 3 4"

MIN SPACE BEHIND ANY

EXPOSED REBARS.

C3

TYPICAL CONCRETE SPALL REPAIR DETAIL

NOT TO SCALE

(E) CONCRETE

WALL

NOTES:

1. PREPARE SURFACE BY REMOVING DUST,

LAITANCE, GREASE, CURING COMPOUNDS, WAXES,

IMPREGNATIONS, FOREIGN PARTICLES,

EFFLORESCENCE AND OTHER BOND INHIBITING

MATERIALS FROM THE SURFACE ADJACENT TO

CRACKS BY MECHANICAL MEANS.

2. REMOVE LOOSE DEBRIS WITH OIL FREE

COMPRESSED AIR.

3. SUBSTRATE SHALL BE SATURATED SURFACE DRY

(SSD) WITH NO STANDING WATER PRIOR TO

APPLICATION OF CRACK SEALANT.

(E) CRACK (E) CRACK

4" MIN

CRACKS GREATER THAN OR EQUAL TO 0.125"

P

R E

P A

R E

S U

R F

A C

E

M

IN

M

IN

ROUTE 18" MIN

WIDE GROOVE AND

APPLY SEAL COAT

OF EPOXY OVER

CRACK. INSTALL

INJECTION PORTS

AND PRESSURE

INJECT CRACK

SEALANT

APPLY SEAL COAT

OF EPOXY OVER

CRACK. INSTALL

INJECTION PORTS

AND PRESSURE

INJECT CRACK

SEALANT

CRACKS GREATER THAN 0.010"

AND LESS THAN 0.125"

(E) CONCRETE

WALL

(E) CONCRETE

WALL

P R

E P

A R

E S

U R

F A

C E

M

IN

M

IN

A3

TYPICAL CONCRETE CRACK REPAIR DETAIL

NOT TO SCALE

F3

REPAIR SCHEDULE

NOT TO SCALE

GENERAL:

A. WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE

BUILDING CODE AS STATED BELOW. HOWEVER, WHERE

REFERENCE IS MADE TO PERFORMANCE CONFORMING TO

OTHER STANDARDS THE MORE STRINGENT SHALL APPLY.

1. THE DEPARTMENT OF DEFENSE, UFC 1-200-01, 8

OCTOBER 2019, INCLUDING CHANGE 1, 1 OCTOBER 2020:

AMENDED IBC, 2018

B. THE CONTRACTOR SHALL COMPARE ALL THE CONTRACT

DOCUMENTS WITH EACH OTHER AND REPORT IN WRITING TO

THE CONTRACTING OFFICER ALL INCONSISTENCIES AND

OMISSIONS.

C. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND

VERIFY FIELD CONDITIONS AND SHALL COMPARE SUCH FIELD

MEASUREMENTS AND CONDITIONS WITH THE DRAWINGS

BEFORE COMMENCING WORK. REPORT IN WRITING TO THE

CONTRACTING OFFICER ALL INCONSISTENCIES AND

OMISSIONS.

D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

COORDINATING THE WORK OF ALL TRADES.

E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR METHODS

OF CONSTRUCTION, WORKMANSHIP AND JOB SAFETY. THE

CONTRACTOR SHALL PROVIDE TEMPORARY SHORING AND

BRACING AS REQUIRED FOR STABILITY OF STRUCTURAL

MEMBERS AND SYSTEMS.

F. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

PROTECTION OF THE ADJACENT PROPERTIES, STRUCTURES,

STREETS AND UTILITIES DURING THE CONSTRUCTION

PERIOD.

G. DETAILS NOTED AS TYPICAL ON THE STRUCTURAL

DRAWINGS SHALL APPLY IN ALL CONDITIONS UNLESS

SPECIFICALLY SHOWN OR NOTED.

CONCRETE REPAIR:

A. BONDING AGENT AND REINFORCING ANTI-CORROSION

COATING:

1. BONDING AGENT AND REINFORCING ANTI-CORROSION

COATING SHALL BE EPOXY-MODIFIED, CEMENTITIOUS

MATERIAL THAT SERVES BOTH AS A BONDING AGENT

FOR THE REPAIR MORTAR AND AN ANTI-CORROSION

COATING FOR REINFORCING.

2. FOLLOW MANUFACTURER’S SPECIFICATIONS FOR

RECOMMENDED TIME BETWEEN APPLICATION OF

BONDING AGENT AND PATCHING MORTAR.

3. THE MINIMUM BOND STRENGTH PROVIDED BY THE

BONDING AGENT SHALL BE 2,400 PSI AFTER 14 DAYS

(ASTM C882/C882M).

B. REPAIR MORTAR:

1. REPAIR MORTAR SHALL BE POLYMER-MODIFIED CEMENT

MORTAR, BE SUITABLE FOR HORIZONTAL, VERTICAL AND

OVERHEAD SURFACES, AND CONTAIN FIBER

REINFORCING AND CORROSION INHIBITOR.

2. THE MINIMUM COMPRESSIVE STRENGTH SHALL BE 5,500

PSI AFTER 28 DAYS (ASTM C109/C109M).

3. THE MINIMUM BOND STRENGTH SHALL BE 2,000 PSI

AFTER 28 DAYS (ASTM C882/C882M).

4. REPAIR MORTAR AND BONDING AGENT/REINFORCEMENT

PROTECTIONS SHALL BE SUPPLIED BY THE SAME

MANUFACTURER AND SHALL BE FULLY COMPATIBLE

WITH EACH OTHER.

C. CRACK REPAIR SEALANT:

1. REPAIR SEALANT SHALL BE TWO COMPONENT, HIGH

MODULUS, LOW VISCOSITY, EPOXY RESIN ADHESIVE.

2. THE MINIMUM BOND STRENGTH PROVIDED BY THE

BONDING AGENT SHALL BE 4,000 PSI AFTER 2 DAYS

(ASTM C882/C882M).

D. REPAIR PRODUCTS SHALL BE INSTALLED IN ACCORDANCE

WITH THE MANUFACTURER'S PUBLISHED INSTRUCTIONS.

E. THE CONTRACTOR SHALL RESTORE TO THEIR ORIGINAL

CONDITION OR BETTER ALL IMPROVEMENTS DAMAGED AS A

RESULT OF THE REPAIR WORK.

F. ALL REPAIR WORK SHALL MATCH ADJACENT SURFACES IN

COLOR, TEXTURE AND ARCHITECTURAL DESIGN.

G. LOCATIONS AND QUANTITIES OF CONCRETE DEFICIENCIES

ARE SHOWN TO PROVIDE AN ESTIMATE OF THE EXTENT AND

TYPE OF REPAIR THAT EXISTS. PRIOR TO THE START OF

CONSTRUCTION THE CONTRACTOR SHALL SOUND

CONCRETE SURFACES TO IDENTIFY AND LOCATE LOOSE OR

DELAMINATED CONCRETE AND CRACKS. ALL DISCOVERED

DEFICIENCIES SHALL BE RECORDED ON SHOP DRAWINGS

AND SUBMITTED TO THE CONTRACTING OFFICER FOR

REVIEW.

H. SHOP DRAWINGS SUBMITTED SHALL INCLUDE DATE AND

TIME OF INSPECTION, LOCATIONS OF DEFICIENCY, SQUARE

FEET OF SPALLED AREA, AND WIDTH AND LINEAL FEET OF

CRACKS. SHOP DRAWINGS SHALL ALSO INCLUDE A TOTAL

SUMMARY OF SQUARE FEET OF SPALL REPAIR AND LINEAL

FEET OF CRACK REPAIR SIMILARLY AS SHOWN ON THE

REPAIR SCHEDULE.

I. CONTRACTOR SHALL PERIODICALLY MONITOR THE SPALLS

AND CRACKS NOTED IN THEIR SHOP DRAWINGS DURING

CONSTRUCTION AND NOTIFY THE CONTRACTING OFFICER IN

WRITING ANY INCREASE IN SIZE OF EXISTING SPALLS AND

CRACKS AND THE OCCURRENCE OF NEW DEFICIENCIES.

SPALL (S.F.) C3/S-001

R2

R3

R4

R5

R6

R7

R8

R9

R10

R11

R12

R13

R14

R15

R16

R17

R18

R19

R20

R21

R22

R23

R31

R32

R33

R34

R35

R36

R37

R38

R39

R40

R41

R42

R43

R44

R45

R46

R47

CONTINGENCY TOTAL

R48

S-001

G E

N E

R A

L N

O T

E S

R

E P

A

IR

S C

H E

D U

L E

T

Y P

IC

A

L R

E P

A

IR

D E

T A

IL

S

JM C

A

D S

O L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T

E D

B Y

D A

T E

C O

N T

R A

C T

N O

C

H E

C K

E D

B Y

D R

A W

N B

Y

IS

S

U E

D A

T E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers ®

BLDG 1795

W

A

-1

-D -0

G

Y M

N A

S

IU

M B

U

IL

D

IN

G

R

E P

A

IR

S A

L

IA

M A

N U

M

IL

IT

A

R Y

R E

S E

R V

A T

IO

N

O

A H

U

H I

IN

K

A R

C H

L L C

H O

N O

L U

L U

H

A W

A

II

P H

O N

E (8

-1

I W

IL

E

I R

O A

D S

U

IT

E

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

H O

N O

L U

L U

H

A W

A

II

A L

IA

M

A N

U M

IL

IT

A R

Y R

E S

E R

V A

T

IO

N

W

A

-1

-D -0

A N

S I

D

/0

/2

JM JM

P:

\D ra fti ng \2

1-

-0

6_

-2 al ia m an u c ad

\W

A_

_D

_0

0_ S-

1.

dw g, /6

/2

3:

:3

PM

, t am an ah a

C1

REPAIR EXTERIOR ELEVATION - EAST

SCALE 1/8" = 1'-0"

E1

REPAIR EXTERIOR ELEVATION - WEST

SCALE 1/8" = 1'-0" E6

REPAIR EXTERIOR ELEVATION - SOUTH

SCALE 1/8" = 1'-0"

C6

REPAIR EXTERIOR ELEVATION - NORTH

SCALE 1/8" = 1'-0"

A B C D E F G

G F E D C B A 5 4 3 2 1

1 2 3 4 5

LEGEND:

R31

R5

R6

R2

R6

R37

R48

R1 INDICATES REPAIR MARK, SEE F3/S-001

OPEN TO

EXISTING

LANAI

OPEN TO

EXISTING

LANAI

R8

R47R10

R9

R13

O' 8' 16' 24'4'

O' 8' 16' 24'4' O' 8' 16' 24'4'

O' 8' 16' 24'4'

(E)

CONCRETE

COLUMN

(E) CONCRETE

SLAB

(E) CONCRETE

WALL

(E)

CONCRETE

COLUMN

(E) CONCRETE

SLAB

(E) CONCRETE

WALL

(E)

CONCRETE

COLUMN

(E)

CONCRETE

COLUMN

INDICATES EXISTING ITEM(E)

R1

R3

R32

R4

R33 R35 R36

R7

R38 R39

R40

R11

R34

R12

R15

R14

R16

R41

R42

R43

R44

R45

R46

B C D E F

A1

REPAIR INTERIOR ELEVATION - EAST

SCALE 1/8" = 1'-0"

R17 R22R18 R21 R23

R20 R19

O' 8' 16' 24'4'

JM C

A

D S

O L

IC

IT

A

T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

M A

R K

S

IZ

E

S U

B M

IT

T

E D

B Y

D A

T E

C O

N T

R A

C T

N O

C

H E

C K

E D

B Y

D R

A W

N B

Y

IS

S

U E

D A

T E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers ®

BLDG 1795

W

A

-1

-D -0

G

Y M

N A

S

IU

M B

U

IL

D

IN

G

R

E P

A

IR

S A

L

IA

M A

N U

M

IL

IT

A

R Y

R E

S E

R V

A T

IO

N

O

A H

U

H I

IN

K

A R

C H

L L C

H O

N O

L U

L U

H

A W

A

II

P H

O N

E (8

-1

I W

IL

E

I R

O A

D S

U

IT

E

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

H O

N O

L U

L U

H

A W

A

II

A L

IA

M

A N

U M

IL

IT

A R

Y R

E S

E R

V A

T

IO

N

W

A

-1

-D -0

A N

S I

D

/0

/2

JM JM

S-201

R E

P A

IR

E

L E

V A

T

IO

N S

P:

\D ra fti ng \2

1-

-0

6_

-2 al ia m an u c ad

\W

A_

_D

_0

0_ S-

1.

dw g, /6

/2

3:

:3

PM

, t am an ah a

±20'-0" ±23'-0" ±23'-0" ±20'-0"

±86'-0"

GENERAL SHEET NOTES

SHEET DEMO KEYNOTES

LEGEND / SYMBOL

A

1 2 3 4

B

C

D

E

F

G

EXISTING STORAGE #1

EXISTING STORAGE #2

EXISTING ELEC

EXISTING GYMNASIUM

EXISTING LANAI

EXISTING CONTROL DESK

EXISTING ROOF LINE

ABOVE SHOWN DASHED

EXISTING TRENCH

DRAIN TO REMAIN

EXISTING ROLL UP DOOR

EXISTING DOOR

TO REMAIN, TYP

EXISTING ROLL

UP DOOR

EXISTING

CONC COL TO

REMAIN, TYP

A1

SCALE: 1/8" = 1'-0"

DEMOLITION FLOOR PLAN

AD101

EXISTING CONCRETE COLUMNS

EXISTING WALL

D E

M O

L I T

I O

N

F

L O

P

A

N

EXISTING DS TO REMAIN,

TYP

EXISTING DOOR AND

DOOR HARDWARE TO

REMAIN, TYP

EXISTING GYM

FLOORING TO REMAIN,

UON

(±11 SF)

(±3 SF)

(±3 SF)

EXISTING WALL LIGHT TO

REMAIN, TYP

APPROXIMATE AREA OF WOOD PLANK

FLOORING REPAIR (AREA IN SQ FT)

EXISTING SIDEWALK TO

REMAIN

EXISTING

LANDSCAPING TO

REMAIN

EXISTING

LANDSCAPING TO

REMAIN

EXISTING

LANDSCAPING TO

REMAIN

EXISTING TILE FLOORING

TO REMAIN, TYP

(NIC)

(NIC)

(NIC)

(NIC)

A. SEE DEMOLITION EXTERIOR ELEVATIONS AND STRUCT

DWGS FOR ADDITIONAL DEMOLITION WORK.

B. SEE SHEET A-601, "WINDOW REFURBISHMENT NOTES" FOR

ADDITIONAL INFORMATION.

D1. REPAIR WOOD PLANKS IN APPROXIMATE LOCATION, SEE

SHEET A-101 FOR ADDITIONAL INFORMATION

D2. DEMOLISH AND REMOVE ALUMINUM LOUVERS, SEE DEMO

EXTERIOR ELEVATIONS FOR MORE INFORMATION.

D3. DEMOLISH AND REMOVE EXISTING EXTERIOR WALL HARD

TILE BASE AND EXCESS MORTAR, COMPLETE. SMOOTH

SURFACE TO MATCH EXISTING ADJACENT CONCRETE

WALL, PREP TO ACCEPT PAINT.

D4. REMOVE EXISTING 3/4" THICK (VERIFY) WOOD PLANK

FLOORING WITH EXPOSED FASTENERS

D5. DEMOLISH AND REMOVE EXISTING DOOR THRESHOLD

D6. DEMOLISH AND REMOVE EXISTING INTERIOR WALL HARD

TILE BASE AND EXCESS MORTAR, COMPLETE. SMOOTH

SURFACE TO MATCH EXISTING ADJACENT CONCRETE

WALL, DO NOT PAINT

(FOR THIS SHT ONLY)

D1

D1

(±4 SF)

D1

(±10 SF)

D4

D1

D2

ABV

D2

ABV

D2

ABV

D2

ABV

D2

ABV

D2

ABV

D2

ABV

D2

ABV

EXISTING SLIDING

WINDOW TO REMAIN, TYP,

SEE DEMO ELEVATIONS

FOR ADDITIONAL WORK

EXISTING SLIDING

WINDOW TO REMAIN, TYP,

SEE DEMO ELEVATIONS

FOR ADDITIONAL WORK

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

PLAN

NORTH

T

R

AD901

XXXX

X

PHOTO REFERENCE

APPROXIMATE PHOTO DIRECTION

PHOTO IDENTIFICATION NUMBER

SHEET REFERENCE

AD901

AD901

AD901

D6

TYP

AD901

D5

D5

D5

DEMO / REMOVE

D3

TYP

DEMO WALL TILE BASE ON EXISTING COLUMNS

D3

TYP

D3 TYP

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

GENERAL SHEET NOTES DEMOLITION SHEET KEYNOTES

D1. DEMOLISH AND REMOVE EXISTING LOUVER, COMPLETE

D2. DEMOLISH AND REMOVE EXISTING ALUM C-CHANNEL @ INTERIOR SIDE

D3. EXISTING ALUM VERTICAL STEEL TUBE TO REMAIN (CONTRACTOR TO

VERIFY HEAD AND SILL CONDITION FOR CORROSION)

D4. DEMOLISH AND REMOVE EXISTING SEALANT AND BACKER ROD (WHERE

OCCURS)

D5. PROVIDE SPALL OR CRACK REPAIR ON EXISTING CONCRETE, SEE

STRUCT SHTS FOR ADDITIONAL INFO

D6. DEMOLISH AND REMOVE EXISTING CONTINUOUS SEALANT AND BACKER

ROD AROUND PERIMETER OF EXISTING WINDOW AS REQUIRED.

EXISTING SLIDING WINDOW TO REMAIN IN PLACE

D7. DEMOLISH AND REMOVE EXISTING INSECT SCREEN, COMPLETE

LEGEND

AD201

E1

SCALE: 1/8" = 1'-0"

DEMOLITION EXTERIOR ELEVATION - WEST

E6

SCALE: 1/8" = 1'-0"

DEMOLITION EXTERIOR ELEVATION - SOUTH (FRONT)

B1

SCALE: 1/8" = 1'-0"

DEMOLITION EXTERIOR ELEVATION - EAST

B6

SCALE: 1/8" = 1'-0"

DEMOLITION EXTERIOR ELEVATION - NORTH

D E

M O

L I T

I O

N

E

X T

E R

I O

R

E

L E

V A

T I O

N S

G F E D C B A 5 4 3 2 1

OPEN TO

EXISTING

LANAI

OPEN TO

EXISTING

LANAI

D2D1TYP

D4

D2

D3

D1TYP

TYP D4TYP

D4TYP D4TYP

GROUND

FLOOR LINE

±0.00

TOP OF COL

TOP OF

UPPER ROOF

TOP OF ROOF

GROUND

FLOOR LINE

±0.00

TOP OF

COL

TOP OF UPPER

ROOF

TOP OF

ROOF

GROUND

FLOOR LINE

±0.00

TOP OF

COL

TOP OF UPPER

ROOF

TOP OF

ROOF

GROUND

FLOOR LINE

±0.00

TOP OF COL

TOP OF

UPPER ROOF

TOP OF ROOF

GROUND LINE

EXISTING TILE TO

REMAIN, TYP

EXISTING ROOF

AWNING AND

EXISTING LOUVERS

TO REMAIN, TYP, PREP

TO ACCEPT PAINT

EXISTING METAL

PANEL AND

FRAME,TO

REMAIN, TYP

EXISTING WALL

LIGHT, DO NOT

PAINT, TYP

EXISTING

GUTTER,

DOWNSPOUT,

AND STRAPS TO

REMAIN, TYP

D3

EXISTING TILE TO

REMAIN, TYP

EXISTING ROOF

AWNING AND EXISTING

LOUVERS TO REMAIN,

TYP, PREP TO ACCEPT

PAINT

EXISTING WALL

LIGHT, DO NOT

PAINT, TYP

EXISTING

GUTTER,

DOWNSPOUT,

AND STRAPS TO

REMAIN, TYP

EXISTING METAL

PANEL AND

FRAME,TO

REMAIN, TYP

EXISTING

CORRUGATED

METAL PANELS

TO REMAIN, TYP

EXISTING

CORRUGATED

METAL PANELS

TO REMAIN, TYP

EXISTING ELEC

PANEL TO

REMAIN

GROUND LINE

EXISTING TILE

TO REMAIN, TYP

EXISTING METAL

PANEL AND FRAME

TO REMAIN, TYP

EXISTING ALUM

LOUVERS TO

REMAIN, TYP

EXISTING

STANDING SEAM

MET ROOF TO

REMAIN, TYP

EXISTING ROLL UP

DOOR TO REMAIN,

TYP, PREP TO

ACCEPT PAINT

EXISTING MET DOOR

TO REMAIN, TYP, PREP

TO ACCEPT PAINT

EXISTING METAL

GRATE TO

REMAIN, TYP

EXISTING TILE

TO REMAIN, TYP

EXISTING METAL

PANEL AND FRAME

TO REMAIN, TYP

EXISTING ALUM

LOUVERS TO

REMAIN, TYP

EXISTING ROLL UP

DOOR TO REMAIN,

TYP, PREP TO

ACCEPT PAINT

EXISTING MET DOOR

TO REMAIN, TYP

GROUND LINE

EXISTING

STANDING SEAM

MET ROOF TO

REMAIN, TYP

EXISTING MET DOOR

TO REMAIN, TYP

D5TYP

DEMOLISH AND REMOVE ITEMS

DEMOLISH AND REMOVE SEALANT

AND BACKER ROD (WHERE

OCCURS)

APPROXIMATE SPALL AREA, SEE

STRUCT DWGS FOR MORE

INFORMATION

D6TYP

D6 TYP

EXISTING

CONCRETE

WALL WITH

REVEAL, TYP

REMOVE AND STORE EXISTING

SIGNAGE FOR REINSTALLATION

±24.33

±38.75

±43.50

±24.33

±38.75

±43.50

±24.33

±38.75

±43.50

±24.33

±38.75

±43.50

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

(FOR THIS SHT ONLY)

A B C D E F G 1 2 3 4 5

EXISTING

GUTTER, TYP

EXISTING

DOWNSPOUT AND

LEADER, TYP

A. GUTTERS, AND DOWNSPOUTS (INCLUDING DOWNSPOUT LEADERS): ALL GUTTERS AND

DOWNSPOUTS SHALL BE THOROUGHLY CLEANED AND FLUSHED FREE OF ALL DEBRIS.

ENSURE ENTIRE DRAINAGE SYSTEMS ARE WATERTIGHT AND ARE FUNCTIONING

PROPERLY. PREVENT ANY, AND ALL DEBRIS FROM DISRUPTING THE DRAINAGE FLOW

THROUGHOUT THE DURATION OF THE PROJECT. SHOULD THE CONTRACTOR DISCOVER

ANY UNFORESEEN DAMAGES OR CORROSION OF GUTTERS AND DOWNSPOUTS, OR

LEADERS, CONTRACTOR SHALL IMMEDIATELY DOCUMENT AND SUBMIT IN WRITING, A

REQUEST FOR INFORMATION ("RFI") FOR FURTHER DIRECTIONS PRIOR TO PROCEEDING

IN THE AFFECTED AREA.

B. CONTRACTOR TO FIELD VERIFY PAINT WORK CONDITIONS. CONTRACTOR TO SAND TO

SMOOTH SURFACE RUST TO ACCEPT PAINT. CONTRACTOR SHALL BE RESPONSIBLE TO

PREP ALL SURFACES PER MANUFACTURERS RECOMMENDATIONS. SEE GENERAL NOTE

#29, SHEET G-002 FOR ADDITIONAL INFORMATION.

C. SEE SHEET A-601, "WINDOW REFURBISHMENT NOTES" FOR ADDITIONAL INFORMATION.

D7

D8. DEMOLISH AND REMOVE EXISTING DOOR THRESHOLD COMPLETE

D9. DEMOLISH AND REMOVE EXISTING WALL HARD TILE BASE AND EXCESS

MORTAR, COMPLETE. SMOOTH SURFACE TO MATCH EXISTING

ADJACENT CONCRETE WALL, PREP TO ACCEPT PAINT.

D8

D8

D8

D9TYP

D9TYP

D9TYP

D9TYP

EXISTING

CONCRETE WALL

WITH REVEAL, TYP

D5TYP

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

AD901

X

I S

T I N

G

R

E F

E R

E N

H O

T O

S

SCALE: NTS

EXISTING REFERENCE PHOTOS

SCALE: NTS

EXISTING REFERENCE PHOTOS

SCALE: NTS

EXISTING REFERENCE PHOTOS

SCALE: NTS

EXISTING REFERENCE PHOTOS

SCALE: NTS

EXISTING REFERENCE PHOTOS

SCALE: NTS

EXISTING REFERENCE PHOTOS

REPLACE MISSING

CEILING PANELS

ACT

PAINT EXISTING GUTTERS,

DOWNSPOUTS AND STRAPS

PT

EXISTING METAL

PANEL AND FRAME,

DO NOT PAINT

EXISTING METAL

PANEL AND FRAME,

DO NOT PAINT

CLEAN EXISTING WINDOWS, SEE

WINDOW REFURBISHMENT

NOTES ON SHEET A-601

DEMOLISH AND REMOVE EXISTING

LOUVER, ALUM C-CHANNEL, AND

INSECT SCREEN, COMPLETE

PAINT EXISTING EXTERIOR

STEEL CHANNELS

PT

SCALE: NTS

EXISTING REFERENCE PHOTOS

DEMOLISH AND REMOVE

EXISTING WALL HARD TILE BASE

PAINT EXISTING EXTERIOR

STEEL ANGLES

PT

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

±20'-0" ±23'-0" ±23'-0" ±20'-0"

±86'-0"

GENERAL SHEET NOTES

SHEET KEYNOTES

1. REFINISH WOOD PLANK FLOORING: SAND TO BARE

WOOD TO ELIMINATE/REDUCE CUPPING OF EXISTING

WOOD PLANKS. SEAL WITH AN OIL-MODIFIED

POLYURETHANE SPORT FLOOR SEALER AND FINISH

WITH A PREMIUM TWO-COMPONENT WATERBORNE

FLOOR FINISHING PRODUCT (COMPATIBLE WITH

SEALER). COMPLETED WORK SHALL MATCH EXISTING

ADJACENT FLOORING SURFACE.

2. REMOVE AND REPLACE EXISTING 3/4" THICK (VERIFY)

WOOD PLANK FLOORING. ANCHOR / FASTEN, SAND AND

FINISH AS REQUIRED AND AS RECOMMENDED PER

WOOD COURT FLOORING MANUFACTURER TO MATCH

EXISTING ADJACENT SURFACE. SEE TECHNICAL SPEC

SECTION 09 64 66 FOR ADDITIONAL INFORMATION.

3. CLEAN EXISTING TRENCH DRAIN OF DEBRIS AND

MAINTAIN THROUGHOUT DURATION OF THIS PROJECT.

TRENCH DRAIN AND GATE TO REMAIN.

4. REFURBISH EXISTING WINDOW, SEE "WINDOW

REFURBISHMENT NOTES" SHEET A-601.

5. PROVIDE CONTINUOUS SEALANT ALONG EXISTING

METAL FLOORING EDGE TRIM AND ADJACENT VERTICAL

CONCRETE WALL SURFACE

LEGEND

EXISTING STORAGE #1

EXISTING STORAGE #2

EXISTING ELEC

EXISTING GYMNASIUM

EXISTING LANAI

EXISTING CONTROL DESK

W06

W04

W03

W01

W02

W05

A

1 2 3 4

B

C

D

E

F

G

A1

SCALE: 1/8" = 1'-0"

FLOOR PLAN

A-101

WINDOW AS SCHED, SEE SHEET A-601 FOR

MORE INFORMATION

EXISTING DOOR TO REMAIN

F L

O O

R

P

L A

N

APPROXIMATE AREA OF WOOD PLANK

FLOORING REPAIR (AREA IN SQ FT)

SEE GENERAL SHEET NOTE 'B', THIS SHEET,

FOR ADDITIONAL INFORMATION

EXISTING ROOF LINE

ABOVE SHOWN DASHED

EXISTING ROLL UP DOOR

(NIC)

EXISTING DOOR

TO REMAIN, TYP

EXISTING ROLL

UP DOOR

(NIC)

EXISTING DS TO REMAIN,

TYP

EXISTING DOOR

AND DOOR

HARDWARE TO

REMAIN, TYP

EXISTING WOOD PLANK

FLOORING

EXISTING CONCRETE COLUMN

EXISTING

CONC COL TO

REMAIN, TYP

EXISTING WALL LIGHT TO

REMAIN, TYP

EXISTING SIDEWALK TO

REMAIN

EXISTING

LANDSCAPING

EXISTING

LANDSCAPING

EXISTING

LANDSCAPING

EXISTING TILE FLOORING

TO REMAIN, TYP

(NIC)

(NIC) (NIC)

(FOR THIS SHT ONLY)

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

PLAN

NORTH

T

R

B

C

D

A. SEE SHEET A-601, "WINDOW REFURBISHMENT NOTES"

FOR ADDITIONAL INFORMATION.

B. WHERE COURT FLOORING IS DAMAGED OR DISTURBED

(INCLUDING THE TAPE MARKINGS/ STRIPING) AS A

RESULT OF THE WORK EFFORTS OF THIS PROJECT. THE

CONTRACTOR SHALL REMOVE AND REPLACE THE WOOD

FLOORING OR STRIPING AS RECOMMENDED BY THE

FLOOR COURT MANUFACTURER TO MATCH THE EXISTING

ADJACENT SURFACE.

C. SEE EXTERIOR ELEVATIONS FOR LOUVER

IDENTIFICATIONS.

(±11 SF)

(±3 SF)

(±3 SF)

(±4 SF)

(±10 SF)

CONTINUOUS SEALANT AT EXISTING

CONCRETE COLUMN / WALL

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

±20'-0" ±23'-0" ±23'-0" ±20'-0"

±86'-0"

±4'-0"

±74'-0"

SHEET KEYNOTES

PAINT NOTE

EXISTING GYMNASIUM

EXISTING LANAI

A

1 2 3 4

B

C

D

E

F

G

A1

SCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN AND UPPER ROOF REFLECTED CEILING PLAN

A-102

R E

F L

E C

T E

D

C

E I L

I N

G

P

L A

N

A

P

O

F

R E

F L

E C

T E

D

C

E I L

I N

G

P

L A

N

UPPER ROOF

DO NOT PAINT

INTERIOR

TRUSS AND

UNDERSIDE

OF

STRUCTURE

1. PAINT EXISTING EXTERIOR STEEL CHANNEL

2. PAINT EXISTING METAL GUTTER AND STRAPS

3. PAINT UNDERSIDE OF METAL DECK

TYP

TYP

TYP

TYP

PT

PT

DO NOT PAINT

INTERIOR

TRUSS AND

UNDERSIDE

OF

STRUCTURE

DO NOT PAINT

INTERIOR

TRUSS AND

UNDERSIDE

OF

STRUCTURE

(FOR THIS SHT ONLY)

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

PLAN

NORTH

T

R

EXISTING LIGHTS, DO NOT

PAINT, TYP

A. CONTRACTOR TO FIELD VERIFY PAINT WORK CONDITIONS.

CONTRACTOR TO SAND TO SMOOTH SURFACE RUST TO

ACCEPT PAINT. CONTRACTOR SHALL BE RESPONSIBLE TO

PREP ALL SURFACES PER MANUFACTURERS

RECOMMENDATIONS. SEE GENERAL NOTE #29, SHEET G-002

FOR ADDITIONAL INFORMATION.

B. CONTRACTOR TO REMOVE BIRD/INSECT NESTS ON EXTERIOR

OF THE BUILDING

PT

TYP

REPLACE MISSING

CEILING TILE PANELS,

VERIFY SIZE AND

COUNT IN FIELD

ACT

PAINT EXISTING EXTERIOR

METAL ANGLE, TYP

PT

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

SHEET KEYNOTES

A-201

A B C D E F

E1

SCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - WEST

E X

T E

R I O

R

E

L E

V A

T I O

N S

E6

SCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - SOUTH (FRONT)

B1

SCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - EAST

B6

SCALE: 1/8" = 1'-0"

EXTERIOR ELEVATION - NORTH

G

G F E D C B A 5 4 3 2 1

1 2 3 4 5

1. URETHANE SEALANT AND BACKER ROD, PAINT TO MATCH

WALL COLOR, SEE DETAIL F1/A-602 AND F3/A-602

2. STORM LOUVER, AS SCHED

3. PAINT CORRUGATED METAL PANELS, ALL SIDES, TYP

4. PAINT CONCRETE, SEE STRUCT DWGS FOR MORE

INFORMATION ON SPALL AND CRACK REPAIR

5. PAINT METAL CHANNELS, SEE RCP FOR MORE INFO

6. PAINT GUTTERS, DOWNSPOUTS, AND STRAPS

7. PAINT MET DOOR FRAME, MET DOOR, TRANSOM PLYWD

PANEL, AND WOOD TRIM

8. PAINT METAL GRATE

9. PAINT METAL ROLL UP DOOR AND FRAME

OPEN

OPEN

TYP

GROUND LINE

GROUND

FLOOR LINE

±0.00

TOP OF COL

TOP OF

UPPER ROOF

TOP OF ROOF

±24.33

±38.75

±43.50

GROUND

FLOOR LINE

±0.00

TOP OF

COL

TOP OF

UPPER

ROOF

TOP OF

ROOF

±24.33

±38.75

±43.50

GROUND

FLOOR LINE

±0.00

TOP OF COL

TOP OF

UPPER ROOF

TOP OF ROOF

GROUND

FLOOR LINE

±0.00

TOP OF COL

TOP OF

UPPER ROOF

TOP OF ROOF

EXISTING ELEC

PANEL, DO NOT

PAINT

EXISTING WALL

LIGHT, DO NOT

PAINT, TYP

TYP

TYP

EXISTING CONCRETE

SLAB, DO NOT PAINT, TYP

EXISTING TILE, DO NOT

PAINT, TYP

TYP

EXISTING METAL PANEL

AND FRAME, DO NOT

PAINT, TYP

TYP

TYP

TYP

GROUND LINE

TYP

TYP

EXISTING TILE, DO NOT

PAINT, TYP

EXISTING METAL

PANEL AND

FRAME, DO NOT

PAINT, TYP

GROUND LINE

TYP

TYP

EXISTING TILE,

DO NOT PAINT,

TYP

EXISTING METAL

PANEL AND FRAME,

DO NOT PAINT, TYP

EXISTING ALUM

LOUVERS, DO

NOT PAINT, TYP

EXISTING

STANDING SEAM

MET ROOF, DO

NOT PAINT, TYP

TYP

EXISTING ROLL UP

DOOR, DO NOT

PAINT, TYP

TYP

TYP

GROUND LINE

TYP

TYP

EXISTING TILE,

DO NOT PAINT,

TYP

EXISTING METAL

PANEL AND FRAME,

DO NOT PAINT, TYP

EXISTING ALUM

LOUVERS, DO

NOT PAINT, TYP

EXISTING

STANDING SEAM

MET ROOF, DO

NOT PAINT, TYP

TYP

TYP

A-602

D3

±24.33

±38.75

±43.50

±24.33

±38.75

±43.50

PT

PT

PT

PT

PT

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

PT

EXISTING

GUTTER, TYP

EXISTING

DOWNSPOUT AND

LEADER, TYP

A. GUTTERS, AND DOWNSPOUTS (INCLUDING DOWNSPOUT LEADERS): ALL GUTTERS AND DOWNSPOUTS

SHALL BE THOROUGHLY CLEANED AND FLUSHED FREE OF ALL DEBRIS. ENSURE ENTIRE DRAINAGE

SYSTEMS ARE WATERTIGHT AND ARE FUNCTIONING PROPERLY. PREVENT ANY, AND ALL DEBRIS FROM

DISRUPTING THE DRAINAGE FLOW THROUGHOUT THE DURATION OF THE PROJECT. SHOULD THE

CONTRACTOR DISCOVER ANY UNFORESEEN DAMAGES OR CORROSION OF GUTTERS AND

DOWNSPOUTS, OR LEADERS, CONTRACTOR SHALL IMMEDIATELY DOCUMENT AND SUBMIT IN WRITING, A REQUEST FOR INFORMATION ("RFI") FOR FURTHER DIRECTIONS PRIOR TO PROCEEDING IN THE

AFFECTED AREA.

B. SEE SHEET A-601, "WINDOW REFURBISHMENT NOTES" FOR ADDITIONAL INFORMATION.

C. CONTRACTOR TO FIELD VERIFY PAINT WORK CONDITIONS. CONTRACTOR TO SAND TO SMOOTH

SURFACE RUST TO ACCEPT PAINT. CONTRACTOR SHALL BE RESPONSIBLE TO PREP ALL SURFACES

PER MANUFACTURERS RECOMMENDATIONS. SEE GENERAL NOTE #29, SHEET G-002 FOR ADDITIONAL

INFORMATION.

GENERAL SHEET NOTES LEGEND

SEALANT

APPROXIMATE SPALL REPAIR

AREA, SEE STRUCTURAL

DRAWINGS FOR ADDITIONAL

INFORMATION

A-602

A3

A-602

B3

TYP

TYP

TYP

SEALANT, TYP

SEALANT, TYP SEALANT,

TYP

TYP

TYP

SEALANT, TYP

A-602

A3

A-602

A3

L

L

L

L

L

L

L

L

PT

9 9

10. PAINT EXISTING METAL AWNINGS (TOP, SIDES, AND

UNDERSIDES) OVER EXISTING LOUVERS (DO NOT

PAINT LOUVERS), TYP

11. SPALL REPAIR, TYP (SEE LEGEND)

12. REINSTALL EXISTING BUILDING PLAQUE SIGNAGE

BACK TO ORIGINAL LOCATION AND CONDITION ( DO

NOT PAINT)

EXISTING LOUVERS, DO

NOT PAINT, TYP

EXISTING LOUVERS, DO

NOT PAINT, TYP

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

T Y

P

A-202

A

B1

SCALE: 1/8" = 1'-0"

INTERIOR ELEVATIONS

B

C D

I N

T E

R I O

R

E

L E

V A

T I O

N S

GENERAL SHEET NOTES SHEET KEYNOTES

1. STORM LOUVER, AS SCHED

2. PAINT METAL GRATE ON ALL EXPOSED SIDES

TYP

TYP

GROUND

FLOOR LINE

±0.00

TOP OF COL

±24.33

GROUND

FLOOR LINE

±0.00

TOP OF COL

±24.33

GROUND

FLOOR LINE

±0.00

GROUND

FLOOR LINE

±0.00

EXISTING LOUVERS TO

REMAIN, TYP

EXISTING METAL PANEL

AND FRAME TO REMAIN,

TYP

EXISTING VERTICAL JOINT

SEALANT ON INTERIOR

SIDE TO REMAIN, TYP

EXISTING STEEL

SECURITY ENCLOSURE

TO REMAIN, TYP

EXISTING CONC TO

REMAIN, TYP

EXISTING STEEL TRUSS

TO REMAIN, TYP

EXISTING TILE TO

REMAIN, TYP

EXISTING SLIDING

WINDOW BEYOND,

SHOWN DASHED, TYP

EXISTING FRAMED

MIRROR TO REMAIN

A. INTERIOR PAINT PATCH WORK REQUIRED WHERE CONCRETE WALL PAINT IS DAMAGED OR MISSING DUE TO DEMOLITION WORK OR NEW

STORM LOUVER INSTALLATION. PAINT SHALL MATCH EXISTING. PAINT PATCH WORK TO TERMINATE AT SURFACE BREAKS OR AT

LOUVER SILL HEIGHT WHICHEVER IS LOWER.

B. SEE SHEET A-601, "WINDOW REFURBISHMENT NOTES" FOR ADDITIONAL INFORMATION.

(FOR THIS SHT ONLY)

SCALE: 1/8"=1'-0"

4' 8' 12' 16' 20' 24'0

PAINT CONCRETE, SEE STRUCT

DWGS FOR MORE INFORMATION ON

SPALL AND CRACK REPAIR, TYP

PT

PT

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

H

W

W

H

H

W

W

H

H

W

WINDOW SCHEDULE

A-601

LOUVER SCHEDULE

LOUVER TYPES

WINDOW TYPES

WINDOW

NUMBER TYPE

SIZE

(APPROXIMATE

ROUGH OPENING)

MATERIAL

DETAIL (SEE SHEET A-602)

WINDOW COVERINGS REMARKSWIDTH HEIGHT FRAME GLAZING HEAD JAMB MULLION SILL

W01 1 ±8'-6 1/2" ±6'-8" EXISTING ALUM EXISTING F5/A-602 D5/A-602 - A5/A-602 N/A

W02 1 ±8'-6 1/2" ±6'-8" EXISTING ALUM EXISTING F5/A-602 D5/A-602 - A5/A-602 N/A

W03 3 ±5'-2 1/2" ±6'-8" EXISTING ALUM EXISTING F5/A-602 D5/A-602,

B3/A-602

- A5/A-602 N/A

W04 2 ±13'-0" ±6'-8" EXISTING ALUM EXISTING F5/A-602 D5/A-602 - A5/A-602 N/A

W05 2 ±13'-0" ±6'-8" EXISTING ALUM EXISTING F5/A-602 D5/A-602 - A5/A-602 N/A

W06

±8'-6 1/2" ±6'-8"

EXISTING ALUM EXISTING F5/A-602 D5/A-602 - A5/A-602 N/A

LOUVER

NUMBER TYPE

SIZE (APPROXIMATE

ROUGH OPENING)

MATERIAL

DETAIL (SEE SHEET A-602)

LOUVER COVERINGS REMARKSWIDTH HEIGHT FRAME HEAD JAMB MULLION SILL

L01 1 ±8'-6 1/2" ±10'-5 1/2" ALUM F7/A-602 D7/A-602

A7/A-602

BIRD SCREEN

L02 2 ±13'-0" ±10'-5 1/2" ALUM

F7/A-602

D7/A-602

B7/A-602

A7/A-602

BIRD SCREEN

L03 2 ±13'-0" ±10'-5 1/2" ALUM

F7/A-602

D7/A-602

B7/A-602

A7/A-602

BIRD SCREEN

L04 1

±8'-6 1/2"

±10'-5 1/2" ALUM

F7/A-602

D7/A-602

A7/A-602

BIRD SCREEN

L05 1 ±8'-6 1/2" ±10'-5 1/2" ALUM

F7/A-602

D7/A-602

A7/A-602

SECURITY SCREEN/BIRD SCREEN

L06 2 ±13'-0" ±10'-5 1/2" ALUM

F7/A-602

D7/A-602

B7/A-602

A7/A-602

SECURITY SCREEN/BIRD SCREEN

L07 2 ±13'-0" ±10'-5 1/2" ALUM F7/A-602 D7/A-602 B7/A-602 A7/A-602 SECURITY SCREEN/BIRD SCREEN

L08 1 ±8'-6 1/2" ±10'-5 1/2" ALUM F7/A-602 D7/A-602 - A7/A-602 SECURITY SCREEN/BIRD SCREEN

EXISTING DOOR

EXISTING METAL

PANEL, TYP

LOUVER AS SCHED,

TYP

EXISTING METAL

PANEL, TYP

LOUVER AS SCHED,

TYP

GROUND LEVEL

EXISTING METAL

PANEL, TYP

GROUND LEVEL

WINDOW AS

SCHED, TYP

EXISTING METAL

PANEL, TYP

GROUND LEVEL

EXISTING METAL

PANEL, TYP

LOUVER AS SCHED,

TYP

GROUND LEVEL

L O

U V

H

E D

U L

E

A

P

E S

W

I N

D O

W

S C

H E

D U

P

E S

F

I N

I S

H

A

T

E R

I A

L

S C

H E

D U

L E

WINDOW TYPE 1 WINDOW TYPE 2 WINDOW TYPE 3

EXISTING SLIDING

GLASS WINDOW

(2) EXISTING SLIDING

GLASS WINDOW

EXISTING SLIDING GLASS

SLIDING WINDOW

FIXED FIXED FIXED FIXED

LOUVER TYPE 1

FIXED STORM

LOUVER

LOUVER TYPE 2

FIXED STORM

LOUVER W/ MULLION

FINISH AND MATERIAL SCHEDULE

1. CONTRACTOR TO FIELD MEASURE ALL OPENINGS TO CONFIRM DOOR, WINDOW, GLAZING AND LOUVER

SIZES PRIOR TO ORDERING MATERIALS NECESSARY TO COMPLETE THE TASK AT HAND.

2. EXISTING CEILING TILE PANELS APPEAR TO BE 5/8" THICK, FIBERGLASS, WITH SCRUBBABLE, UV-PROTECTED, WITH VINYL FILM FACING, HUMIDITY/SAG AND MOLD/MILDEW RESISTANT.

CONTRACTOR TO VERIFY.

NOTES

WINDOW REFURBISHMENT NOTES

1. THE CONTRACTOR SHALL BE REQUIRED TO FURNISH ALL NECESSARY LABOR, EQUIPMENT, TOOLS, AND

MATERIAL FOR CLEANING THE WINDOW GLAZING AND FRAMES (BOTH INTERIOR AND EXTERIOR FACES)

FOR ALL EXISTING WINDOWS "W01" THROUGH "W06", AS WELL AS THE EXISTING WINDOWS ON THE

NORTH AND SOUTH SIDES OF THE BUILDING. THIS WORK SHALL INCLUDE (BUT NOT LIMITED TO):

CLEAN ALL WINDOW FRAMES OF EVIDENCE OF DIRT, GRIME, ENVIRONMENTAL CONTAMINANTS,

AND CORROSION WITH AN INDUSTRY STANDARD, COMMERCIAL-GRADE ALUMINUM CLEANER,

COMPATIBLE WITH THE WINDOW FRAME, USING AN APPROPRIATE CLEANING METHOD (PER

MANUFACTURER'S RECOMMENDATIONS).

RESTORE ALL WINDOW FRAMES USING A HIGH PERFORMANCE, SILICONE AND ACRYLIC POLYMER

BASED, TWO-CLEAR COAT, METAL PROTECTION COATING SYSTEM (PER MANUFACTURER'S

RECOMMENDATIONS).

CLEAN ALL WINDOW SLIDER TRACKS AND WEEP HOLES. ENSURE WEEP HOLES ARE FREE OF ALL

DUST AND DEBRIS. WINDOW SHALL FUNCTION AS INTENDED

ALL GASKETING SHALL BE REPLACED WITH NEW - MATCH EXISTING

GLASS SHALL BE CLEANED WITH A MILD DETERGENT. GLASS IS CLEAN WHEN ALL WINDOW

SURFACES ARE WITHOUT STREAKS, FILM, DEPOSITS AND STAINS

WINDOWS SHALL BE CLEANED IN SUCH A MANNER WITH MINIMUM INCONVENIENCE AND

DISTURBANCE TO BUILDING OCCUPANTS

THE CONTRACTOR SHALL PROTECT ALL SURROUNDING INTERIOR SURFACES FROM WATER

DAMAGE

LUBRICATE SLIDER TRACKS AND WHEELS WITH SILICONE SPRAY

2. THE COMPLETION OF THE WINDOW REFURBISHMENT WORK SHALL HAVE AN END RESULT OF WINDOWS

THAT ARE CLEAN, COMPLETELY FUNCTIONAL, AND OPERATIONAL, AND WITH CONTROLLED WATER

INFILTRATION AND DISBURSEMENT BY DIRECTING ALL MOISTURE TO THE SILL THAT WILL WEEP WATER

BACK TO THE EXTERIOR.

3. THE WORK SHALL BE SUBJECT TO INSPECTION AND APPROVAL BY THE CONTRACTING OFFICER OR

DESIGNATED AGENT.

MULLION @

INTERIOR,SHOWN

DASHED

MULLION @

INTERIOR, SHOWN

DASHED, TYP

CODE

MATERIAL

PAINT

FORMULA

CODE FINISH/SHEEN COLOR ADDITIONAL REMARKS

FS-01

FLOOR

SEALER - - - - GYM FLOORING

PT-01

EXTERIOR

PAINT SEE SPEC SATIN

MATCH

EXISTING -

CONCRETE WALLS, METAL DOOR

FRAME, DOOR, TRANSOM

PT-02

EXTERIOR

PAINT SEE SPEC SEMI GLOSS

MATCH

EXISTING -

STEEL C CHANNELS, METAL

WALL GRATE

PT-03

EXTERIOR

PAINT SEE SPEC SEMI GLOSS

MATCH

EXISTING -

CORRUGATED METAL PANEL,

GUTTERS, DS, AND STRAPS

PT-04

EXTERIOR

PAINT SEE SPEC SEMI GLOSS

MATCH

EXISTING - METAL DECKING

ACT-1 ACOUSTICAL

CEILING TILE - TEXTURED WHITE

CONTRACTOR

TO VERIFY

MATCH EXISTING TILE, SEE NOTE

#2 BELOW

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

±1/2"

±1/2"

SHEET KEYNOTES

1. STORM LOUVER, AS SCHEDULED

2. EXISTING CONCRETE WALL

3. BIRD SCREEN (PER LOUVER MANUFACTURER), AS

SCHEDULED

4. EXISTING ALUMINUM MULLION POST

5. SHIM, AS REQUIRED

6. CONTINUOUS SEALANT AND BACKER ROD

7. EXISTING ALUMINUM HEADER

8. EXISTING METAL PANEL

9. SECURITY SCREEN, WHERE OCCURS, SEE LOUVER

SCHEDULE

10.EXISTING ALUMINUM SLIDING WINDOW

11.EXISTING ALUMINUM FRAME

12.EXISTING CONCRETE COLUMN

13.URETHANE PAINTABLE SEALANT W/ BACKER ROD

14.EXISTING SEALANT AND BACKER ROD, AND SHIM

15.EXISTING METAL GRATE, SHOWN DASHED

16.FASTENER, AS REQUIRED

17.EXISTING WOOD TRIM

18.EXISTING DOOR AND FRAME

19.MULLION, PER MANUFACTURER REQUIREMENTS, SHOWN

DASHED

20.COMMERCIAL RAIN DRIP

- MATERIAL: 6063-T6 ALUMINUM ALLOY AND TEMPER

RETAINER

- COLOR: CLEAR ANODIZED

- WIDTH: 2 1/2"

- HEIGHT: 5/8"

21.COMMERCIAL DOOR BOTTOM SWEEP WITH RAIN DRIP

- MATERIAL: 6063-T6 ALUMINUM ALLOY AND TEMPER

RETAINER

- COLOR: CLEAR ANODIZED

- WIDTH: 2"

- HEIGHT: 9/16"

22.COMMERCIAL THRESHOLD

- MATERIAL: 6063-T6 ALUMINUM ALLOY AND TEMPER

RETAINER

- COLOR: MILL FINISH

- WIDTH: 4"

- HEIGHT: 1/2"

23.THRESHOLD SET IN CONTINUOUS BED OF SEALANT, WITH

ADDITIONAL CONTINUOUS SEALANT ALONG LEADING

FRONT EDGE OF THRESHOLD AND ALONG PROFILE OF

BOTH SIDE JAMB FRAMES AT FLOOR LINE, SEE DETAIL

D1/A-602

(FOR THIS SHT ONLY)

F7

SCALE: 3" = 1'-0"

LOUVER DETAIL - HEAD

A7

SCALE: 3" = 1'-0"

@ EXISTING METAL PANEL

D7

SCALE: 3" = 1'-0"

LOUVER DETAIL - JAMB

B7

SCALE: 3" = 1'-0"

LOUVER DETAIL - MULLION

A-602

L O

U V

T

A I L

S

W

I N

D O

W

D

E T

A I L

S

M I S

C E

L L

A N

E O

T

A I L

S

EXTERIORINTERIOR

EXTERIORINTERIOR

EXTERIORINTERIOR

EXTERIORINTERIOR

BOTH SIDES,

TYP

BOTH

SIDES,

TYP

F5

SCALE: 3" = 1'-0"

WINDOW DETAIL - HEAD

EXISTING STEEL

TUBE

D5

SCALE: 3" = 1'-0"

WINDOW DETAIL - JAMB

A5

SCALE: 3" = 1'-0"

WINDOW DETAIL - SILL

F3

SCALE: 3" = 1'-0"

JOINT SEALANT DETAIL

TYP

EXTERIOR

INTERIOR

WHERE

OCCURS

EXISTING SEALANT

AND BACKER ROD

WHERE

OCCURS

FACE OF EXISTING

CONCRETE

COLUMN WHERE

OCCURS

L O

U V

Z

E

H

E D

U L

E D

L O

U V

Z

E

H

E D

U L

E D

L O

U V

Z

E

H

E D

B5

SCALE: 3" = 1'-0"

WINDOW DETAIL - JAMB

D3

SCALE: 3" = 1'-0"

DOOR DETAIL - JAMB

BELOW

EXISTING STEEL

POST

BOTH SIDES,

TYP

BOTH SIDES,

TYP

EXTERIORINTERIOR

EXTERIORINTERIOR

EXTERIORINTERIOR

EXTERIORINTERIOR

CONT

SEALANT

EXISTING

WEEP HOLE

EXTERIOR

INTERIOR

EXISTING

STEEL POST

EXISTING

SEALANT AND

BACKER ROD

9"3"

SCALE: 3"=1'-0"

1'6"0

CONT SEALANT

W/ BACKER ROD

EXISTING CONC

PRECAST PANELS

ALUM WINDOW SILL

B3

SCALE: 3" = 1'-0"

HEAD/WEATHER STRIP

DOOR DETAIL -

EXTERIORINTERIOR

EXTERIORINTERIOR

EXISTING

QUARRY

TILE

A3

SCALE: 3" = 1'-0", 6" = 1'-0"

THRESHOLD/WEATHER STRIP

DOOR DETAIL -

EXISTING

CONC SLAB

SEALANT

LOUVER DETAIL - SILL

F1

NOT TO SCALE

PERSPECTIVE DETAIL

JOINT SEALANT

D1

NOT TO SCALE

PERSPECTIVE DETAIL

THRESHOLD

EXTERIOR

INTERIOR

SCALE: 6"=1'-0"

6"3"0

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

BLDG 1795

W

A

D

M

N A

S I U

M

B

U I L

D I N

G

R

E P

A I R

S

A L

I A

M A

L

I T

A R

Y

R

E S

E R

V A

T I O

N

O

A H

U

H

I

W

A

D

A N

S I

D

C o

S

D K

O R

S C

O T

T

R

J

H

A R

A D

A

A

I A

SIGNATURE

No. 14637

ARCHITECT

PROFESSIONAL

LICENSED

H

A

W

A

I I , U

S

O

T

T

R

J.

A

D

A

H

File details come from the government source that posted it. Updated .