This federal contract opportunity solicitation requests offers for painting tainter gates at the Ozark Lock and Dam. The project has a magnitude between $1 million and $5 million, is set aside for total small businesses, and involves NAICS code 237990 for other heavy and civil engineering construction. Interested offerors can attend a site visit on August 11, 2020 or submit questions through a request for information on www.projnet.org through August 18. The soliciting agency is the U.S. Army Corps of Engineers Little Rock District.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CESWL-EC-DI

SUBJECT: FY2016 Ozark L&D #12, Tainter Gate Inspection Report, Ozark, Arkansas

Gate 1 – Worst Gate in the District

Side Seal Leakage around – Gate 1

Bent WT 6x22.5 – Gate 1

Missing WT Brace – WT6x22.5 – Gate 1

Broken Wide Flange Brace W14x30 – Gate 1

Broken Brace WT6x22.5 – Large tree needs to be removed – Gate 1

Severe Section Loss of the WT 6x22.5 Brace – Gate 1

Large log is destroying the gate – 2 Bent W14x30 Braces – Gate 1

Section Loss of Brace – WT 6x22.5 – Gate 1

Fix Bent Vertical Strut W14x30 – Gate 1

Fix or Replace 2 Bent Beams – W14x30 – Gate 1

Gate 2 – Remove Safety Chain it is getting caught in the trunnion

Test Paint Deterioration – Gate 2

Rust Pits in Skin Plate

Cavitation Pits at the Bottom of the Gate 2

Bent W14x30 Brace – Gate 2

Test Paint is coming off in sheets – Gate 2

Bent and broken flange – W14x30 – Gate 2

Piece of wood hooked to the safety chain stuck in trunnion

Bent & Corroded WT Brace – Gate 2

Cavitation on the bottom knife edge – Gate 2

Bent WT 6x22.5 – Remove Log Safely

Remove channel buoy from bottom tray – Gate 2

Bent & Corroded WT 6x22.5 Brace – Gate 2

Gate 2 embedde Seal – 2nd pour void or gap

Gate 2 – Remove Log from under the bottom girder

Center WT6x22.5 is laying in the bottom Girder – Gate 3

Center WT6x22.5 is laying in the bottom Girder – Gate 3

Corrosion of the end WT rib – Gate 3

Corrosion due to Leaking Side Seal – Gate 3

Bent Vertical Brace W14x30

Bent W14x30 – Remove Log and Repair – Gate 3

Gate 3 – Corroded WT 6x22.5 Brace

Gate 3 – Remove broken member do not use it on the gate

Gate 3 Bent Corroded WT 6x22.5 Brace

Remove Log and fix W14x30

Remove Log and fix W14x30

WT 6x22.5 – Section Loss

Remove Log from the bottom of – Gate 3

Gate 7 – Safety Chain Stuck in the Trunnion – Remove Safety Chain from Pier

Replace or Adjust Side Seal – Gate 7

Gate 7 – Bent WT6x22.5

Corrosion Pits in Strut Arm

Gate 7 – Bent WT6x22.5 Brace

Bent & Corroded WT6x22.5 Brace – Gate 7

Bent & Corroded WT6x22.5 Brace – Gate 7

Bent & Corroded WT6x22.5 Brace

Remove Log from the bottom of Gate 7

Bent W14x30 – Gate 7

Depleted Anodes U/S Gate 7

Cavitation of the bottom lip Gate 7

Corroded Side Seal Angle – Gate 7

Side Seal Leakage on Gate 8

Bent WT6x22.5 – Gate 8

Bent Flange W14x30 – Gate 8

Heavy Corrosion of WT-Ribs and Log – Gate 8

Gate 8 – Remove Log and Repair Flanges

Corroded Side Seal Angle & Wear Plate – Gate 8

Depleted Anodes – Gate 8

Paint is deteriorating on the top strut arm - Gate 9

Gate 9 – Trunnion Casting Yoke

Gate 9 – Remove Large Logs & Repair Braces

Gate 9 – Bent WT

Gate 9 Side seal leakage

Gate 9 - Remove Logs

Gate 9 Heat Straight WT web

Gate 9 - Remove Tire

Gate 9 – Replace Side Seal - Corrosion

Gate 10 – Remove logs and Fix W14x30 Strut Arm Braces W14x30

Gate 10 – Needs to be Painted

Gate 10 - Fatigue Crack or Torsion crack in WT Brace

Gate 10 Replace Anodes

Gate 10 Remove Log below bottom Girder

Gate 10 – Cavitation on the bottom of the skin plate

Gate 11 – Remove log and Repair W14x30

Gate 11 – Leaking Side Seal

Gate 11 – Remove Tree & Repair W14x30 Braces

Gate 11 – Heat Straighten or Replace WT6x22.5 Brace

Gate 11 – Weld Corrosion Hole W14x30

Gate 11 – Remove Log below Bottom Girder

Gate 11- Heat Straighten W14x30 Flanges

Gate 11- Remove Log and Replace WT6x22.5

Gate 11 – Replace WT6x22.5

Gate 11 – Large Log and Bent Braces

Bent Center WT6x22.5

Gate 12 - Remove Log & Repair Braces

Gate 12 – Repair Bent Flanges and WT Braces

Gate 12 – Replace WT6x22.5 Brace

Gate 12 – WT 6x22.5 Braces have corroded webs – Section Loss

Damage Pier 13