COMMUNICATION SYMBOLS
FLOOR BOX WITH (2) CATEGORY 6 CABLES
WAP
WIRELESS ACCESS POINT - (2) CATEGORY 6 CABLES ABOVE
CEILING. TERMINATE CABLES TO AN RJ45 MODULAR PLUG. LEAVE
10' CABLE SLACK MINIMUM, AT EACH LOCATION. MOUNT TO WALL
6" ABOVE CEILING WHEREVER POSSIBLE. OTHERWISE SUSPEND
FROM CONTRACTOR PROVIDED HANGER
GENERAL NOTES:
1. SCOPE OF WORK FOR NETWORK AND COMMUNICATIONS
AS INDICATED ON DRAWINGS ARE FOR CORE/SHELL ONLY.
2. ALL OTHER WORK INDICATED ON DRAWINGS ARE FOR
REFERENECE ONLY.
3. REFER TO DRAWING T-401 FOR MDF/IDF ROOM LAYOUT.
4. REFER TO DIVISION 27 SPECIFICATIONS FOR STRUCTURED
CABLING REQUIREMENTS.
5. ALL WORK SHALL ADHERE TO ALL NATIONAL AND LOCAL
CODES AND GOVERNMENT AND INDUSTRY STANDARDS.
6. CABLE TRAY FOR HORIZONTAL AND BACK BONE CABLING
SHALL BE PROVIDED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR (DIVISION 26).
7. CONDUIT, SLEEVES, BACK BOXES, TMGB, TGB AND ELECTRICAL
OUTLETS SHALL BE PROVIDED AND INSTALLED BY THE
ELECTRICAL CONTRACTOR (DIVISION 26). COORDINATE WITH
ELECTRICAL DRAWINGS.
NETWORK AND COMMUNICATIONS ABBREVIATIONS:
AFF ABOVE FINISHED FLOOR
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
AWG AMERICAN WIRE GAUGE
C CONDUIT
CCTV CLOSED CIRCUIT TELEVISION
CLG CEILING
COAX COAXIAL CABLE
EIA ELECTRONIC INDUSTRIES ASSOCIATION
EM EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
FB FLOOR BOX
FC FINISHED CEILING
GND GROUND
IDF INTERMEDIATE DISTRIBUTION FRAME
IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS
JB JUNCTION BOX
LAN LOCAL AREA NETWORK
MDF MAIN DISTRIBUTION FRAME
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OF OPTICAL FIBER
PB PULL BOX
POS POINT OF SALE
PT POKE-THRU
PVC POLYVINL CHLORIDE SCHEDULE 40 OR AS NOTED
STP SHIELDED TWISTED PAIR
TBB TELECOMMUNICATIONS BONDING BACKBONE
TBD TO BE DETERMINED
TGB TELECOMMUNICATIONS GROUNDING BUS BAR
TMGB TELECOMMUNICATIONS MAIN GROUNDING BUS BAR
TYP TYPICAL
TV TELEVISION
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UTP UNSHIELDED TWISTED PAIR
WP WEATHER PROOF
CPE CUSTOMER PREMISE EQUIPMENT
OSP OUTSIDE PLANT
SM SINGLE MODE
(1) CATEGORY 6 CABLE - HI-IMPACT WITH WALL PLATE. INSTALL
CABLE TO ROOM 233 AV RACK. PROVIDE DEEP BACK BOX WITH
MINIMUM 1"C TO CORRIDOR CABLE TRAY OR ACCESSIBLE
CEILING AREA.
C
MOUNTING HEIGHTS:
W
- WALL PHONE - 48" A.F.F.
8. ALL CAT 6 CABLING AT THE WORK AREA END SHALL HAVE A
MINIMUM OF 10'-0" OF SLACK TO ACCOMODATE FLEXIBILITY IN
FUTURE RECONFIGURATIONS. COORDINATE SLACK LENGTH
WITH OWNER PRIOR TO TERMINATION OF CABLES.
POE POWER OVER ETHERNET
CATV CABLE TELEVISION
# = NUMBER OF CATEGORY 6 CABLES, OTHER THAN TWO,
TO DESIGNATED IDF
(2) CATEGORY 6 CABLES TO DESIGNATED IDF @18" AFF UNLESS
NOTED OTHERWISE ON FLOOR PLANS.
PROVIDE BACK BOX WITH 1"C TO CORRIDOR CABLE TRAY OR
ACCESSIBLE CEILING AREA.
CATEGORY 6 CABLES TO DESIGNATED IDF. LEAVE 10' SLACK AT
WORK AREA. @18" AFF UNLESS NOTED OTHERWISE ON FLOOR
PLANS
# = NUMBER OF CABLES (OTHER THAN TWO)
W WALL PHONE - (1) CATEGORY 6 CABLE TO DESIGNATED IDF.
PROVIDE BACK DEEP BOX WITH MINIMUM 1"C TO CORRIDOR
CABLE TRAY OR ACCESSIBLE CEILING AREA.
RW ROOM WIZARD
(1) CAT 6 CABLE - TO ROOM 233 AV RACK (WALL)
#=QUANTITY GREATER THAN ONE. PROVIDE DEEP BACK BOX WITH
MINIMUM 1"C TO CORRIDOR CABLE TRAY OR ACCESSIBLE CEILING
AREA. HI IMPACT OUTLET.
C#
-18" A.F.F. UNLESS NOTED
OTHERWISE ON FLOOR PLANS
C -18" A.F.F. UNLESS NOTED OTHERWISE
ON FLOOR PLANS
TV -60" A.F.F. UNLESS NOTED
OTHERWISE ON FLOOR PLANS
(1) COAX CABLE - RG6 WITH F-CONNECTOR WALL PLATE.
INSTALL CABLE TO NEAREST IDF. PROVIDE DEEP BACK BOX
WITH MINIMUM 1"C TO CORRIDOR CABLE TRAY OR
ACCESSIBLE CEILING AREA.
TV
9. ALL CAT 6 CABLING TO BE TERMINATED USING THE T568B
WIRING CONFIGURATION.
10. USE WHITE CABLE FOR VOICE ONLY (ANALOG) LOCATIONS, AND
BLUE CABLE FOR DATA (DIGITAL) LOCATIONS.
11. THE STANDARD ADMINISTRATIVE OUTLET BOX SHALL BE
DOUBLE GANG WITH A DOUBLE GANG FACEPLATE. EACH
ADMINISTRATIVE OUTLET SHALL CONSIST OF 2 CAT 6 RATED
MODULAR CONNECTORS. WIRE ALL COPPER OUTLETS, PATCH
PANELS, AND CONNECTORS PER T568B FOR NEW
CONSTRUCTION.
12. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL PATCH
CABLES. PROVIDE (2) PATCH CORDS FOR EVERY CATEGORY 6
CABLE INSTALLED, AND (1) PATCH CORD FOR EACH FIBER
STRAND INSTALLED. CATEGORY 6 SHALL BE 10' FOR WORK
AREA, AND 10' FOR TR. OPTICAL FIBER SHALL BE 3 METERS.
(1) HDMI CABLE FROM SOURCE AS NOTED. PROVIDE DEEP BACK
BOX WITH MINIMUM 1"C TO CORRIDOR CABLE TRAY OR
ACCESSIBLE CEILING AREA.
H
CABLE TRAY LEGEND:
7' - 8"
12" x 4"
BASKET TRAY
ELEVATION
TRAY WIDTH x TRAY HEIGHT
TRAY TYPE
OUTLET TYPE:
WP = HUBBELL WP826MPHI NEMA 3R WEATHERPROOF OUTLET COVER.
REQUIRES BR106OW OUTLET FRAMES.
13. CABLING TO SYSTEM FURNITURE SHALL BE ENCLOSED IN
FLEXIBLE DUCT TO THE POINT OF ENTRY OF THE
FURNITURE RACEWAY. FACEPLATES SHALL BE COMPATIBLE
WITH SYSTEM FURNITURE MANUFACTURER.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-001
T E
L E
C O
M M
U N
IC
A
T
IO
N S
G E
N E
R A
L N
O T
E S
S
Y M
B O
L S
A
N D
A B
B R
E V
IA
T
IO
N
S
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal molokia John Oneill Disclaimer 082118
DN
DN
1 2 4 5 6
A
B
D
E
Cx
Dx
7 8 9
F
9.6
A.2
6x
A.5
9.1
T-401
D2
G
A.1
6x
A.5
BREAK/ KITCHEN
MACHINE SHOP
HYPOBARIC
PROCEDURE
ROOM
HYPERBARIC
PROCEDURE
ROOM - 1
HYPERBARIC
PROCEDURE
ROOM - 2
OFFICE
OFFICE
OFFICE
MECHANICAL
OFFICE
CLEAN ROOM
OFFICE
OFFICE
OFFICE
TECH OFFICE
DIRECTOR
DEPUTY
DIRECTOR
NCOIC
RECEPTION
ADMINISTRATIVE
OFFICER
NAVY RSD
ADMIN ASST
RESIDENTS
OFFICE
OFFICE
SUPPLY
COPY AREA
DAH OFFICE
X-RAY
ANIMAL PREP
SURGERY
INSTRUMENT
PREP/SCRUB
COLD FEED
STORAGE
IT
WOMEN'S LOCKER
ROOM
MEN'S LOCKER
ROOM
ELEVATOR
MACHINE ROOM
STUDY/LIBRARY
CONFERENCE
ROOM
WELD SHOP
COMPRESSOR
MEDICAL SUPPLY
STERILIZER
VACUUM ROOM
EXAM
LOADING DOCK
NAVY LAB
RODENT HOLDING
174A
PROCEDURE/
RODENT HOLDING
174B
RODENT HOLDING
174C
RODENT SUITE #1
PROCEDURE/
RODENT HOLDING
174E
RODENT HOLDING
174D
STORAGE/
RODENT HOLDING
174F
STORAGE/
RODENT HOLDING
176A
PROCEDURE/
RODENT HOLDING
176B
RODENT HOLDING
176C
RODENT HOLDING
176D
PROCEDURE/
RODENT HOLDING
176E
RODENT HOLDING
176F
RODENT SUITE #2
JC
JC
CORRIDOR
CORRIDOR
FORMALIN
STORAGE ROOM
NAVY SUITE
CORRIDOR
ELEVATOR
MACHINE ROOM
EXIT STAIR
EXIT STAIR B
CYL MANIFOLD
JC
ELEVATOR #1
ELEVATOR #2
INSTRUMENTATION
MAINTENANCE
SHOCK TUBE #3
PROCEDURE
ROOM
SHOCK TUBE #2
HOLDING
CORRIDOR
ENTRY VESTIBULE
TELECOM
CONFERENCE
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
ANTE ROOM
ANTE ROOM
SHOCK TUBE #1
JC
VESTIBULE
ELECTRICAL
ROOM
CORRIDOR
EXIT STAIR
EXIT STAIR
OFFICE
CORRIDOR
ELECTRICAL
CLOSET
194B
SECURITY OFFICE
132B
6x
A.5
C
T-401
A2
SCALE: 1/8"=1'-0"
08 4
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
A B
C
PLAN NORTH
KEYPLAN
J .S
T
IP
E
T-101
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
O V
E R
A L L
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
WAP
WAP
WAP
WAP WAP WAP
W
A P
1 2 4 5 6
A
B
6x
A.5 x
8' - 3 27/32"
12"
BASKET TRAY
4"
6x
A.5
W
W
W
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TECH OFFICE
DIRECTOR
DEPUTY
DIRECTOR
X-RAY
CONFERENCE
ROOM
NAVY SUITE
CONFERENCE
EXIT STAIR
CORRIDOR
1-1/4" CONDUIT FROM PODIUM
FLOOR BOX, TO ABOVE
CEILING, FOR AV AND
NETWORK CABLING
1-1/4" CONDUIT FROM PODIUM FLOOR
BOX, TO ABOVE CEILING, FOR AV AND
NETWORK CABLING
COORDINATE OUTLET HEIGHT WITH
SMART BOARD INSTALLATION
48" AFF MOUNTING HEIGHT. TYPICAL
PROVIDE A POLYCOM
SOUNDSTATION IP 7000,
WITH (5) CEILING HUNG
MICROPHONES.
6x
A.5
OUTLET @ 7'-0" AFF
(2) CATEGORY 6 CABLES
TO PODIUM FLOOR BOX.
OUTLET @ 7'-0" AFF
(2) CATEGORY 6 CABLES
TO PODIUM FLOOR BOX.
OUTLET @ 6'-6" AFF
(2) CATEGORY 6 CABLES
TO PODIUM FLOOR BOX.
H H
M A
T C
H L
IN
E
A
T
-1 B
MATCHLINE
/A1 T-101A2
M A
T C
H L
IN
E
A
T
-1 B
C
SEE ELECTRICAL DRAWINGS FOR
PATHWAYS AND FLOOR BOX
INFORMATION.
SEE SHEET T-505
DETAILS D1 AND D5
FOR MORE INFORMATION
SCALE: 1/8"=1'-0"
08 4
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-101A1
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
A
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-101A1
A1
TELECOM FIRST FLOOR - PART A1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
WAP WAP
WAP
WAP
1 2 4 5 6
B
D
E
Cx
Dx
F
6x x
8' - 3 27/32"
12"
BASKET TRAY
4" x
8' - 10"
12"
BASKET TRAY
4" x
8' - 10"
6"
BASKET TRAY
4" x
8' - 10"
6"
BASKET TRAY
4" x
8' - 3"
6"
BASKET TRAY
4" x
8' - 3"
6"
BASKET TRAY
4"
W
+60"
6x
W
W
W
W
W
W
BREAK/ KITCHEN
DIRECTOR
DEPUTY
DIRECTOR
NCOIC
RECEPTION
ADMINISTRATIVE
OFFICER
NAVY RSD
ADMIN ASST
RESIDENTS
OFFICE
SUPPLY
COPY AREA
X-RAY
ANIMAL PREP
SURGERY
INSTRUMENT
PREP/SCRUB
IT
WOMEN'S LOCKER
ROOM
MEN'S LOCKER
ROOM
ELEVATOR
MACHINE ROOM
MEDICAL SUPPLY
NAVY LAB
CORRIDOR
CYL MANIFOLD
JC
ELEVATOR #1
ENTRY VESTIBULE
LARGE ANIMAL
HOLDING ROOM
CORRIDOR
6x x
7' - 6"
12"
LADDER TRAY
2"
MATCHLINE
/A1 T-101A1
MATCHLINE
/A1 T-101B1
MATCHLINE
/A1 T-101B3
MATCHLINE
/A1 T-101A3
WALL PHONE IN WEATHERPROOF
GAITRONICS ENCLOSURE
x
8' - 10"
12"
BASKET TRAY
4" CORRIDOR
CORRIDOR
LOADING DOCK
CORRIDOR
NAVY LAB
+49"
TV
WP
+46"
WP
+46" WP
WP
WP+46"
+44"
WP
WP
WP
+49"
C
WP
WP
B2
E-101A3
SEE ELECTRICAL DRAWINGS FOR
PATHWAYS AND FLOOR BOX
INFORMATION.
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-101A2
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
A
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-101A2
A1
TELECOM FIRST FLOOR - PART A2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
WAP
WAP
WAP
1 2 4 5 6
E
F
6x
HYPOBARIC
PROCEDURE
ROOM
OFFICE
OFFICE
SUPPLY
COPY AREA
DAH OFFICE
STERILIZER
VACUUM ROOM
EXAM
LOADING DOCK
FORMALIN
STORAGE ROOM
ELEVATOR
MACHINE ROOM
EXIT STAIR
ELEVATOR #2
COLD FEED
STORAGE
x
8' - 10"
12"
BASKET TRAY
4" x
8' - 10"
6"
BASKET TRAY
4" x
8' - 10"
6"
BASKET TRAY
4" x
8' - 3"
6"
BASKET TRAY
4"
G
6x
W
W
W
W
W
W
SECURITY OFFICE
132B
6x x
8' - 10"
12"
BASKET TRAY
4"
MATCHLINE
/A1 T-101A2
M A
T C
H L
IN
E
A
T
-1 B
M A
T C
H L
IN
E
A
T
-1 B
WALL PHONE IN WEATHPROOF ENCLOSURE
+50"
ANALOG LINE
FOR ELEVATOR
INSTALL TO EXISTING
PANEL
+46"
+46"
WP
WP
WP
SEE ELECTRICAL DRAWINGS FOR
PATHWAYS AND FLOOR BOX
INFORMATION.
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-101A3
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
A
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-101A3
A1
TELECOM FIRST FLOOR - PART A3
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP WAP
WAP WAP
A
B
7 8 9
9.6
6x
A.5
9.1 x
8' - 3"
6"
BASKET TRAY
4"
A.1
6x
A.5
11111
W
W
W
WELD SHOP
COMPRESSOR
RODENT HOLDING
174A
PROCEDURE/ RODENT
HOLDING
174B
RODENT HOLDING
174C
RODENT SUITE #1
PROCEDURE/ RODENT
HOLDING
174E
RODENT HOLDING
174D
STORAGE/ RODENT HOLDING
174F
STORAGE/ RODENT HOLDING
176A
PROCEDURE/ RODENT
HOLDING
176B
RODENT HOLDING
176C
RODENT HOLDING
176D
PROCEDURE/ RODENT
HOLDING
176E
RODENT HOLDING
176F
RODENT SUITE #2
JC
JC
CORRIDOR
ANTE ROOM
ANTE ROOM
SHOCK TUBE #1
JC
VESTIBULE
6x
A.5
M A
T C
H L
IN
E
A
T
-1 A
M A
T C
H L
IN
E
A
T
-1 A
MATCHLINE
/A1 T-101B2
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP+46"
WP
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
WP
WPWPWPWPWP
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-101B1
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
B
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-101B1
A1
TELECOM FIRST FLOOR - PART B1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP WAP
B
D
E
Cx
Dx
7 8 9
F
A.2
6x x
8' - 3"
6"
BASKET TRAY
4"
6x
11111
W
W
W
W
MACHINE SHOP
MECHANICAL
OFFICE
CLEAN ROOM
CORRIDOR
CORRIDOR
INSTRUMENTATION
MAINTENANCE
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
ANTE ROOM
ANTE ROOM
SHOCK TUBE #1
JC
VESTIBULE
EXIT STAIR
6x
MATCHLINE
/A1 T-101B1
MATCHLINE
/A1 T-101A1
MATCHLINE
/A1 T-101B3
MATCHLINE
/A1 T-101A3 x
8' - 3"
6"
BASKET TRAY
4"
WP WP
WP
WP WP WP
WP
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-101B2
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
B
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-101B2
A1
TELECOM FIRST FLOOR - PART B2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
E
7 8 9
F
6x
HYPOBARIC
PROCEDURE
ROOM
149 HYPERBARIC
PROCEDURE
ROOM - 1
HYPERBARIC
PROCEDURE
ROOM - 2
CORRIDOR
EXIT STAIR
x
8' - 3"
6"
BASKET TRAY
4"
G
6x
W
W
6x
MATCHLINE
/A1 T-101B2
M A
T C
H L
IN
E
A
T
-1 A
W
FINAL LOCATION OF CAMERA TO
BE COORDINATED WITH GOVERNMENT.
SEE DETAIL A1/T-504 FOR MORE
INFORMATION.
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-101B3
F
IR
S T
F L O
O R
T E
L E
C O
M M
U N
I C A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
B
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-101B3
A1
TELECOM FIRST FLOOR - PART B3
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
1 2 4 5 6
A
B
D
E
Cx
Dx
7 8 9
F
10 11
9.6 13
A.2
6x
A.5
9.1
G
A.1
6x
A.5
LARGE ANIMAL
HOLDING
LARGE ANIMAL
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING /
STORAGE
NON HUMAN
PRIMATE
HOLDING /
STORAGE
MEN'S LOCKER
ROOM
WOMEN'S LOCKER
ROOM
LAUNDRY
JANITOR CLOSET
ENRICHMENT
STORAGE
KITCHEN (FOOD
PREP)
X-RAY / DENTAL
MEDICAL SUPPLY
TREATMENT/
ANIMAL PREP
SURGERY
OR SCRUB/PREP
ICU
AIR LOCK
SOILED CAGE
WASH
CLEAN CAGE
WASH
STORAGE
SECURITY
EQUIPMENT
OFFICE
MECHANICAL
MECHANICAL
EXIT STAIR
EXIT STAIR B
CORRIDOR
AIR LOCK
AIR LOCK
CORRIDOR
CORRIDOR
ELEVATOR #1
ELEVATOR #2
CORRIDOR
PROCEDURE
ROOM
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
ANTE ROOM
ANTE ROOM
LARGE ANIMAL
HOLDING
LARGE ANIMAL
HOLDING
STORAGE
LARGE ANIMAL
HOLDING
PROCEDURE
ROOM
ANTE ROOM
ANTE ROOM
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING /
STORAGE
NON HUMAN
PRIMATE
HOLDING
ANTE ROOM
LARGE ANIMAL
HOLDING
EXIT STAIR
EXIT STAIR
MECHANICAL
UPPER
251B
CORRIDOR
6x
A.5
CORRIDOR
AV RACK
LOCATION
SEE DETAIL A4 AND B1
ON SHEET T-505
TWO 4" CONDUITS
FROM 2ND FLOOR CEILING
TO TR 137 BELOW.
FOR WORK AREA CABLING.
C
SCALE: 1/8"=1'-0"
08 4
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
A B
C
PLAN NORTH
KEYPLAN
J .S
T
IP
E
T-102
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
O V
E R
A L L
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/8" = 1'-0"T-102
A1
TELECOM SECOND FLOOR - OVERALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
1 2 4 5 6
A
B
6x
A.5
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING / STORAGE
NON HUMAN PRIMATE
HOLDING / STORAGE
AIR LOCK
STORAGE
NON HUMAN PRIMATE
HOLDING / STORAGE
ANTE ROOM
EXIT STAIR
6x
A.5
W
W
6x
A.5
MATCHLINE
/A1 T-102A2
M A
T C
H L
IN
E
A
T
-1 B
M A
T C
H L
IN
E
A
T
-1 B
WP
WP
WP
WP
+46"
WP
C
WP
WP
WP
C
WP
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-102A1
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
A
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-102A1
A1
TELECOM SECOND FLOOR - PART A1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
WAP
WAP WAP
1 2 4 5 6
B
D
E
Cx
Dx
F
6x
LARGE ANIMAL HOLDING
LARGE ANIMAL HOLDING
MEN'S LOCKER ROOM
WOMEN'S LOCKER ROOM
LAUNDRY
JANITOR CLOSET
ENRICHMENT STORAGE
KITCHEN (FOOD PREP)
STORAGE
CORRIDOR
ELEVATOR #1
CORRIDOR
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING
LARGE ANIMAL HOLDING
LARGE ANIMAL HOLDING
LARGE ANIMAL HOLDING
ANTE ROOM
LARGE ANIMAL HOLDING
6x
W
W
W
W
6x
MATCHLINE
/A1 T-102A1
MATCHLINE
/A1 T-102B1
MATCHLINE
/A1 T-102B3
MATCHLINE
/A1 T-102A3
WP
WP
WP
WP
WP
W
C
C
C
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-102A2
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
A
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-102A2
A1
TELECOM SECOND FLOOR - PART A2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
WAP
1 2 4 5 6
E
F
6x
G
6x
W
W
W
6x
NON HUMAN
PRIMATE
HOLDING
SOILED CAGE
WASH
CLEAN CAGE
WASH
STORAGE
SECURITY
EQUIPMENT
OFFICE
EXIT STAIR
CORRIDOR
CORRIDOR
ELEVATOR #1
ELEVATOR #2
CORRIDOR
228.1
B1
T-505
MATCHLINE
/A1 T-102A2
M A
T C
H L
IN
E
A
T
-1 B
M A
T C
H L
IN
E
A
T
-1 B
WP
WP
WP
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-102A3
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
A
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-102A3
A1
TELECOM SECOND FLOOR - PART A3
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
C
A
B
7 8 9 10 11
6x
A.5
9.1
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING
X-RAY / DENTAL
CORRIDOR
ANTE ROOM
ANTE ROOM
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING
MECHANICAL
A.1
6x
A.5
W
6x
A.5
M A
T C
H L
IN
E
A
T
-1 A
M A
T C
H L
IN
E
A
T
-1 A
MATCHLINE
/A1 T-102B2
WP
WP
WP
WP WP
WP
WP
WP
WP WP
WP
WP
WP
C
C
C
C C
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-102B1
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
B
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-102B1
A1
TELECOM SECOND FLOOR - PART B1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
WAP
WAP
WAP
WAP
WAP
WAP
B
D
E
Cx
Dx
7 8 9
F
6x
X-RAY / DENTAL
MEDICAL SUPPLY
TREATMENT/ ANIMAL PREP
SURGERY
OR SCRUB/PREP
ICU
AIR LOCK
MECHANICAL
AIR LOCK
CORRIDOR
PROCEDURE ROOM
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING
PROCEDURE ROOM
6x
W
W
6x
MATCHLINE
/A1 T-102B1
MATCHLINE
/A1 T-102A1
MATCHLINE
/A1 T-102B3
MATCHLINE
/A1 T-102A3
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
+46"
WP
C
+46"
WP
WP
WP
WP
C
+46"
WP
WP
C
C
WP
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-102B2
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
B
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-102B2
A1
TELECOM SECOND FLOOR - PART B2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
E
7 8 9
F
10 11 126x
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING
AIR LOCK
ANTE ROOM
ANTE ROOM
NON HUMAN PRIMATE
HOLDING
NON HUMAN PRIMATE
HOLDING
G
6x6x
MATCHLINE
/A1 T-102B2
MATCHLINE
/A1 T-102A2
WP
WP
+46"
WP
WP
WP
+46"
WP
WP
WP
WP
C
C
C
C
02 4 8134
SCALE: 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
KEYPLAN
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
CA1
A2
A3
B1
B2
B3 PLAN NORTH
J .S
T
IP
E
T-102B3
S E
C O
N D
F L O
O R
T E
L E
C O
M M
U N
IC
A
T
IO
N S
C A
B L
IN
G P
L A
N
P A
R T
B
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/4" = 1'-0"T-102B3
A1
TELECOM SECOND FLOOR - PART B3
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
E
IT
WALLS COVERED WITH 3/4"x4'x8' A/C
GRADE FLAME RETARDANT PLYWOOD
6" VERTICAL CABLE
MANAGEMENT. TYPICAL
TELECOM
GROUND BUSBAR
(TMGB)
CONNECTION TO
MAIN ELECTRICAL
GROUND
ROOM 137
POWER PANEL
LB1H
W
2-POST RACK.
TYPICAL
SECURITY PANELS
12"x2" CABLE TRAY 7'-6" A.F.F.
CABLE MANAGER FOR 2-POST RACK
WALL PHONE
4'-0" A.F.F.
2-POST RACK
TELECOM GROUND BAR
7'-0" A.F.F.
OCCUPANCY SENSOR
4'-0" A.F.F.
DUPLEX RECEPTACLE
1'-6" A.F.F.
DUPLEX RECEPTACLE
1'-6" A.F.F.
BMS PANELS
SECURITY PANEL
E
E
11 12
2-POST RACK
1/0 AWG BACKBONE
CONNECTION TO
ROOM 137
VERTICAL WIRE
MANAGER
DOUBLE DOORS
TELECOM
GROUND BUSBAR
(TGB)
WALLS COVERED WITH
3/4"x4'x8' A/C GRADE FLAME
RETARDANT PLYWOOD
W
12"x2" CABLE TRAY 7'-6" A.F.F.
DUPLEX RECEPTACLE
1'-6" A.F.F.
OCCUPANCY SENSOR
4'-0" A.F.F.
DUPLEX RECEPTACLE
1'-6" A.F.F.
WALL PHONE
4'-0" A.F.F.
TELECOM GROUND BAR
7'-0" A.F.F.
2-POST RACK
CABLE MANAGER FOR 2-POST RACK
(2) 4" CONDUITS
9'-10" A.F.F.
(1) 1" CONDUIT
9'-0" A.F.F.
(2) 2" CONDUITS
9'-0" A.F.F.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-401
T E
L E
C O
M M
U N
IC
A
T
IO
N S
E N
L A
R G
E D
P L A
N S
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
1/2" = 1'-0"T-401
D2
TR-1 ROOM 137
T-401
C4
TR-1 ROOM 137
ELECTRICAL PANELS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1
1/2" = 1'-0"T-401
A2
TR-2 ROOM 193
T-401
A4
TR-2 ROOM 193
molokia JohnOneill_031417_seal
BUILDING 503
ROOM GS20
TR-1 ROOM 137TR-2 ROOM 193
NEW 48 STRAND SINGLEMODE
EXISTING 200 PAIR MUST BE PULLED
BACK AND REINSTALLED, FOR NEW
IN-BUILDING CONDUIT ROUTING.
12 STRAND
SINGLEMODE
FUSION SPLICE IN RACK
ENCLOSURE
MECHANICAL TERMINATION IN RACK
ENCLOSURE
EXISTING UNDERGROUND
PATHWAY
MECHANICAL TERMINATION IN RACK
2 OR 3. TO BE COORDINATED WITH
GOVERNMENT, AT TIME OF
INSTALLATION.
BUILDING 500
EXISTING SINGLE MODE & MULTI MODE.
MUST BE PULLED BACK AND REINSTALLED
FOR NEW IN-BUILDING CONDUIT ROUTING
WIRE MESH BASKET TYPE
CABLE TRAY
ALL THREAD ROD
SECURED TO FIBER
TROUGH STRINGER
STRUT ABOVE
PLASTIC
THREADED ROD
COVER
CABLE HANGER
TRAPEZE KIT,
USED UNDER
FIBER TROUGH
GENERAL NOTES:
1. CABLE TRAY SHALL MEET NEMA CLASS 8C.
2. ONLY FACTORY SPLICE PLATES, EXPANSION PLATES AND MOUNTING HARDWARE SHALL BE USED.
3. CABLE TRAY SHALL NOT BE USED AS A WALKWAY.
4. SEE PLANS FOR CABLE TRAY SIZES.
5. BOND/GROUND WIRE TRAY BASKET IN ACCORDANCE WITH SPECIFICATION AND DETAILS SHOWN ON ##
WIRE MESH BASKET
TRAY TYPE CABLE
TRAY
90 DEGREE SPLICE BAR AND
HARDWARE FROM
MANUFACTURER
WIRE MESH BASKET
TYPE CABLE TRAY
ATTACHED WITH SPLICE
WASHER, NUTS, AND
BOLT
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-501
N E
T W
O R
K A
N D
C O
M M
U N
IC
A
T
IO
N S
F
IB
E R
O P
T
IC
C A
B L E
B A
C K
B O
N E
A N
D C
A B
L E
T R
A Y
D E
T A
IL
S
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
6" = 1'-0"T-501
A1
WIRE BASKET UNDER FIBER TROUGH HANGER DETAIL
6" = 1'-0"T-501
A3
WIRE BASKET 90 DEGREE RADIUS DETAIL
6" = 1'-0"T-501
A5
WIRE BASKET RADIUS DETAIL
NTST-501
C1
NEW AND EXISTING BACKBONE CABLING
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
APPROVED MANUFACTURERS:
THHN/THWN WIRES FOR SERVICE OF 600 VOLTS AND LESS SHALL
BE MANUFACTURED BY AMERICAN INSULATED WIRE
CORPORATION, SOUTHWIRE, GENERAL CABLE, AETNA
INSULATED WIRE, CERRO WIRE AND CABLE, OR SUPERIOR
ESSEX.
EXISTING
IDF
RM 137
NEW IDF
RM 193
TGB
TMGB
MINIMUM #4/0 AWG
CONTINUOUS FROM DEMARC
TO IDF
TO ELECTRICAL ENTRANCE FACILITY
MAIN BUILDING GROUND
EXISTING AWG
CONNECTION
EXISTING ELECTRICAL PANEL
TELECOMMUNICATIONS MAIN
GROUNDING BUSBAR
STAND-OFF BRACKET
COPPER GROUND BAR
INSULATORS
CABLE TAG (TYP BOTH ENDS)
XXX
DO NOT
DISCONNECT
LEAD
TO TELECOM
CONDUITS
TO TELECOM SERVICE PANEL
XC. WARNING SIGNAGE
XD. BOND CONDUCTOR
COMPRESSION CRIMP
CABLE TAGS
XA. TMGB
TO GROUND
BUS BAR
FOURTH CRIMP
THIRD CRIMP
D O
N O
T
L E
A D
D
IS
C O
N N
E C
T
SECOND CRIMP
FIRST CRIMP
(8 m m
(125mm)
5"
WARNING
X X
X
#4(21.2mm²)
INSULATED GREEN
BONDING
CONDUCTOR (TYP)
GROUNDING ELECTRODE
CONDUCTOR TO
ELECTRICAL ENTRANCE
FACILITY
MOUNT TMGB
UNDER CABLE
TRAY (UNO)
TMGB
TO TELECOM
LADDER RACKS
AND CABLE TRAY
TO TELECOM CONDUITS
TELECOMMUNICAT
IONS MAIN
GROUNDING
BUSBAR
ENGRAVED WHITE LABEL
WITH RED
LETTERING TO BE
INSTALLED NEAR TMGB
& TGB
COMPRESSION
CONNECTOR (TYP BOTH
ENDS)
CLEAR HEAT SHRINK OMITTED FOR CLARITY
CRIMPING LOCATION (TYP BOTH ENDS)
OPEN SLOT: ENSURE
CABLE IS INSERTED
COMPLETELY INTO LUG
COMPRESSION
CONNECTOR
(TYP BOTH ENDS)
NO MORE THAN 3/16"(4MM)
PROTRUDING FROM
END OF LUG
IF THESE CONNECTORS OR
CABLES ARE LOOSE
OR MUST BE REMOVED
PLEASE CALL THE
BUILDING
TELECOMMUNICATIONS
MANAGER
REFER TO
ELECTRICAL DWG
X
FOR SIZING AND
ROUTING OF
GROUNDING
CONDUCTOR
BUILDING
ELECTRICAL
GROUNDING
SYSTEM.
DEDICATED TELCOM
SERVICE PANEL
EQUIPMENT
RACK
GROUNDING
STRIP
LADDER RACK
CEILING
FLOOR SLAB
NOTE:
D3
TO TELECOM CONDUITS/SLEEVES
TELECOM/SLEEVES
CONDUIT(S) WITH
FIRE STOP PROVIDED BY
FIRE
STOP CONTRACTOR
TMGB
(TELECOMMUNICATIONS
MAIN GROUNDING BUSBAR)
COPPER "C-TAP" CLAM CRIMP
CONNECTOR (TYPICAL)
#4(21.2mm²)
INSULATED GREEN
CONDUCTOR)
#6 (13.3mm²) AWG GREEN
INSULATED CONDUCTOR
(TYPICAL)
1/0 INSULATED
GREEN
CONDUCTOR
ALL NETWORK SWITCHES
REQUIRE SEPARATE #6 GROUND
BETWEEN GROUNDING PAD ON
SWITCH AND GROUND STRIP ON
EACH RACK.
T-503
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-502
T E
L E
C O
M M
U N
IC
A
T
IO
N S
G R
O U
N D
IN
G
S Y
S T
E M
S
IN
G L E
L I N
E P
L A
N A
N D
D E
T A
IL
S
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
12" = 1'-0"T-502
D2
TYPICAL GROUNDING BUSBAR DETAIL
12" = 1'-0"T-502
D5
GROUNDING SCHEME DETAIL
NTST-502
C3
GROUNDING SYSTEM SINGLE LINE PLAN
*SIZE CONDUCTORS, PER TIA REQUIREMENTS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
2RU WIRE MANAGER
PRIMARY OPTICAL FIBER
CISCO 4507
BY GOVERNMENT
RACK 1
COPPER BACKBONE
RACK 2
FIRST FLOOR WIRELESS ACCESS POINT CABLING
FIRST FLOOR WORK AREA CABLING
EXISTING MULTIMODE FIBER
OPTICAL FIBER
SPLICE DRAWER
FIRST FLOOR WORK AREA CABLING
FIRST FLOOR WORK AREA CABLING
FIRST FLOOR WORK AREA CABLING
FIRST FLOOR WORK AREA CABLING
SECOND FLOOR WORK AREA CABLING
SECOND FLOOR WORK AREA CABLING
SECOND FLOOR WIRELESS ACCESS POINT CABLING
6" VERTICAL CABLE MANAGER
FIRST FLOOR WORK AREA CABLING
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-503
R A
C K
P R
O F
IL
E
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B S
P E
N C
E R
B M
E S
K
IL
L
NTST-503
B2
PHASE 3 RACK ELEVATIONS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/1
/1
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
GAITRONICS
255-003 - GRAY
WITH RJ45 CONNECTOR
FLOOR BOX/POKE
THRU POWER/DATA
FURNITURE FEED
(2) RJ-45
TYPE JACKS
SYSTEMS FURNITURE FACEPLATE
(COODINATE LOCATION AND FACEPLATE
TYPES WITH SYSTEMS FURNITURE VENDOR)
SYSTEMS FURNITURE
(2) BLANK INSERTS
(2) 18/2 FROM CAMERA TO POWER SUPPLY IN TR 197
(1) RG6 FROM CAMERA TO
BAVM MODULATOR IN ROOM 233
BAVM-1
TR
ROOM 193
ALTRONIX
ALTV248UL
POWER SUPPLY
ROOM 233
PELCO
FD5-V SERIES
ACTUAL LOCATION
TBD
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-504
T E
L E
C O
M M
U N
IC
A
T
IO
N S
D E
T A
IL
S
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B M
E S
K
IL
L
B M
E S
K
IL
L
B M
E S
K
IL
L
NTST-504
D1
AVAYA 9611G PHASE 2
PROVIDE (1) 9611G TELEPHONE
AT EACH (2) CATEGORY 6, AND WALL PHONE, LOCATION
SHOWN ON FLOOR PLANS.
COORDINATE FINAL LOCATIONS AND QUANTITIES WITH
TSRM DOCUMENT .
INCLUDE WALL MOUNT ADAPTER WHERE NECESSARY
NTST-504
D3 T568B Wiring Scheme
NTST-504
B1
FORT DETRICK LABELING SCHEME
NTST-504
D5 Weatherproof Enclosure
12" = 1'-0"T-504
A5
FURNITURE DETAIL
6" = 1'-0"T-504
A1
OUTDOOR CAMERA
NOT TO SCALE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/3
/1
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1
REVISED ENTIRE SHEET
molokia JohnOneill_031417_seal
PODIUM
FRONT WALL TV
SIDE WALL TV 1
SIDE WALL TV 2
HDMI
HDMI
HDMI
HDMI
VGA/AUDIO
MINI-DP
COMPOSITE AV
INPUTS OUTPUT
HDMI
HDMI
SPLITTER
SECOND FLOOR
12' - 0"
SECOND FLOOR
12' - 0"
2' - 3 1/2"
3' x 3' PLYWOOD13RU OPEN RACK
LEGEND:
CUSTOMER SWITCH
CATEGORY 6 PATCH PANEL
FOR NHP TV LOCATIONS
CABLE MANAGEMENT
WRAIR SWITCH
WALL MOUNT RACK
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
J .S
T
IP
E
T-505
A V
D E
T A
IL
S
A N
D D
I A G
R A
M S
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B R
M
B R
M
C h e c k e r
12" = 1'-0"T-505
D5
CONFERENCE ROOM AV
T-505
D1 Conference Room AV
3' x 3' PLYWOOD BACKBOARD
1/2" = 1'-0"T-505
B1 Room 233 AV Rack
12" = 1'-0"T-505
A1
Z-BAND
HDMI CABLE
CATEGORY 6 CABLE
CATEGORY 6
PATCH CABLE
12" = 1'-0"T-505
A4
AV RACK ELEVATION
70" FLAT SCREEN MONITOR50" FLAT SCREEN MONITOR
PODIUM
CATEGORY 6
TO NHP ROOMS
NETWORK SWITCH BY
GOVERNMENT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
DN
DN
WAP
WAP
1 2 4 5 6
A
B
D
E
Cx
Dx
7 8 9
F
9.6
A.2
6x
A.5
9.1
G
A.1
6x
A.5
6x
A.5
BREAK/ KITCHEN
MACHINE SHOP
HYPOBARIC
PROCEDURE
ROOM
HYPERBARIC
PROCEDURE
ROOM - 1
HYPERBARIC
PROCEDURE
ROOM - 2
OFFICE
OFFICE
OFFICE
MECHANICAL
OFFICE
CLEAN ROOM
OFFICE
OFFICE
OFFICE
TECH OFFICE
DIRECTOR
DEPUTY
DIRECTOR
NCOIC
RECEPTION
ADMINISTRATIVE
OFFICER
NAVY RSD
ADMIN ASST
RESIDENTS
OFFICE
OFFICE
SUPPLY
COPY AREA
DAH OFFICE
X-RAY
ANIMAL PREP
SURGERY
INSTRUMENT
PREP/SCRUB
COLD FEED
STORAGE
IT
WOMEN'S LOCKER
ROOM
MEN'S LOCKER
ROOM
ELEVATOR
MACHINE ROOM
STUDY/LIBRARY
CONFERENCE
ROOM
WELD SHOP
COMPRESSOR
MEDICAL SUPPLY
STERILIZER
VACUUM ROOM
EXAM
LOADING DOCK
NAVY LAB
RODENT HOLDING
174A
PROCEDURE/
RODENT HOLDING
174B
RODENT HOLDING
174C
RODENT SUITE #1
PROCEDURE/
RODENT HOLDING
174E
RODENT HOLDING
174D
STORAGE/
RODENT HOLDING
174F
STORAGE/
RODENT HOLDING
176A
PROCEDURE/
RODENT HOLDING
176B
RODENT HOLDING
176C
RODENT HOLDING
176D
PROCEDURE/
RODENT HOLDING
176E
RODENT HOLDING
176F
RODENT SUITE #2
JC
JC
CORRIDOR
CORRIDOR
FORMALIN
STORAGE ROOM
NAVY SUITE
CORRIDOR
ELEVATOR
MACHINE ROOM
EXIT STAIR
EXIT STAIR B
CYL MANIFOLD
JC
ELEVATOR #1
ELEVATOR #2
INSTRUMENTATION
MAINTENANCE
SHOCK TUBE #3
PROCEDURE
ROOM
SHOCK TUBE #2
HOLDING
CORRIDOR
ENTRY VESTIBULE
TELECOM
CONFERENCE
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
LARGE ANIMAL
HOLDING ROOM
ANTE ROOM
ANTE ROOM
SHOCK TUBE #1
JC
VESTIBULE
ELECTRICAL
ROOM
CORRIDOR
EXIT STAIR
EXIT STAIR
OFFICE
CORRIDOR
ELECTRICAL
CLOSET
194B
SECURITY OFFICE
132B
TR1-1-1-A&B
TR1-1-2-A&B
TR1-1-3-A&BTR1-1-4-A&BTR1-1-5-A&B
TR1-1-6-A&B
TR1-1-7-A&B
TR1-1-8-A&B
TR1-1-9-A&B
TR1-1-10-A&B
TR1-1-11-A&B
TR1-1-12-A&B
TR1-1-13-A&B
TR1-1-14-A&BTR1-1-15-A&B
TR1-1-23-A&B
TR1-1-24-A&B
TR1-2-25-A&B
TR1-1-16-A&B
TR1-1-17-A&B TR1-1-18-A&B
TR1-1-19-A&B
TR1-1-20-A&B
TR1-1-21-A&B
TR1-2-26-A&B
TR1-2-27-A&B
TR1-2-28-A&B
TR1-2-29-A&B
TR1-2-30-A&B
TR1-2-31-A&B
TR1-2-32-A&B
TR1-2-33-A&B
TR1-2-34-A&B TR1-2-36-A&B
TR1-2-35-A&B
TR1-2-38-A&B
TR1-2-37-A&B
TR1-2-40-A&B
TR1-2-39-A&B
TR1-2-41-A&BTR1-2-42-A&B
TR1-2-46-A&B
TR1-2-43-A&B
TR1-2-44-A&B
TR1-2-45-A&B
TR1-2-47-A&B
TR1-2-48-A&B
TR1-3-57-A&B
TR1-3-58-A&B
TR1-3-59-A&B
TR1-3-60-A&B TR1-3-52-A&B
TR1-3-53-A&B
TR1-3-54-A&B
TR1-3-55-A&B
TR1-3-56-A&B TR1-3-67-A&B
TR1-3-68-A&B
TR1-3-51-A&B
TR1-3-50-A&B
TR1-3-49-A&B
TR1-1-22-A&B
TR1-3-62-A&B
TR1-3-61-A&B
TR1-3-63-A&B TR1-3-64-A&B TR1-3-66-A&B
TR1-3-65-A&B
TR1-3-69-A&B
TR1-3-70-A&B
TR1-3-71-A&B
TR1-3-72-A&B
TR1-4-73-A&B
TR1-4-74-A&B
TR1-4-75-A&B
TR1-4-77-A
TR1-4-78-A
TR1-4-79-A
TR1-4-76-A&B
TR1-4-80-A
TR1-4-81-A
TR1-4-82-A
TR1-4-86-A
TR1-4-85-A
TR1-4-84-A
TR1-4-87-A
TR1-4-88-A
TR1-4-89-A
TR1-4-83-A&B
TR1-4-90-A&B
TR1-4-91-A&B
TR1-4-92-A&B
TR1-4-94-A&B
TR1-4-93-A&B
TR1-4-95-A&B
TR1-5-98-A
TR1-4-
96-A&B
TR1-5-
97-A
TR1-5-
99-A
(1) RG6 @60" AFF
TO TR
COIL FOR FUTURE USE
TR1-5-
100-A
TR1-5-
102-A
TR1-5-
103-A
TR1-5-
104-A
TR1-5-
105-A
TR1-5-
107-A
TR1-5-
106-A
TR1-5-
108-A
TR1-5-
109-A
TR1-5-
110-A
TR1-5-
112-A&B
TR1-5-
114-A&B
TR1-5-
113-A&B
TR1-5-
115-A&B
TR1-5-
116-A&B
TR1-5-
117-A&B
TR1-5-
118-A&BTR1-5-
119-A
TR1-5-
111-A
TR1-5-
101-A
TR1-5-
120-A&B
TR1-5-
121-A&B
TR1-5-
122-A&B
TR1-5-
123-A&B
TR1-5-
124-A&B
TR1-5-
125-A&B
TR1-5-
126-A&B
TR1-5-
127-A&B
TR1-5-
128-A&B
TR1-6-
129-A&B
TR1-6-
130-A&B
TR1-6-
131-A&B
TR1-6-
132-A&B
C
SCALE: 1/8"=1'-0"
08 4
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
A B
C
PLAN NORTH
KEYPLAN
J .S
T
IP
E
T-506
F
IR
S T
F L O
O R
R O
U T
IN
G
A N
D T
A G
G
IN
G P
L A
N
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B R
M
B R
M
C h e c k e r
1/8" = 1'-0"T-506
TELECOM FIRST FLOOR - OVERALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
C
WAP
1 2 4 5 6
A
B
D
E
Cx
Dx
7 8 9
F
10 11
9.6 13
A.2
6x
A.5
9.1
G
A.1
6x
A.5
6x
A.5
LARGE ANIMAL
HOLDING
LARGE ANIMAL
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING /
STORAGE
NON HUMAN
PRIMATE
HOLDING /
STORAGE
MEN'S LOCKER
ROOM
WOMEN'S LOCKER
ROOM
LAUNDRY
JANITOR CLOSET
ENRICHMENT
STORAGE
KITCHEN (FOOD
PREP)
X-RAY / DENTAL
MEDICAL SUPPLY
TREATMENT/
ANIMAL PREP
SURGERY
OR SCRUB/PREP
ICU
AIR LOCK
SOILED CAGE
WASH
CLEAN CAGE
WASH
STORAGE
SECURITY
EQUIPMENT
OFFICE
MECHANICAL
MECHANICAL
EXIT STAIR
EXIT STAIR B
CORRIDOR
AIR LOCK
AIR LOCK
CORRIDOR
CORRIDOR
ELEVATOR #1
ELEVATOR #2
CORRIDOR
PROCEDURE
ROOM
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
ANTE ROOM
ANTE ROOM
LARGE ANIMAL
HOLDING
LARGE ANIMAL
HOLDING
STORAGE
LARGE ANIMAL
HOLDING
PROCEDURE
ROOM
ANTE ROOM
ANTE ROOM
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING
NON HUMAN
PRIMATE
HOLDING /
STORAGE
NON HUMAN
PRIMATE
HOLDING
ANTE ROOM
LARGE ANIMAL
HOLDING
EXIT STAIR
EXIT STAIR
MECHANICAL
UPPER
251B
CORRIDOR
RISER
FROM TR BELOW
TR1-8-133-A&B
TR1-8-134-A&B
TR1-8-135-A&B
TR1-8-136-A&B
TR1-8-137-A&B
TR1-8-138-A&B
TR1-8-139-A&B
TR1-8-140-A&B
TR1-8-141-A&B
TR1-8-142-A&B
TR1-8-143-A&B
TR1-8-
144-A&B
TR1-8-145-A&B
TR1-8-
146-A&B
TR1-8-147-A&B
TR1-8-147-A&B
TR1-8-
149-A&B
TR1-8-
148-A&B
TR1-8-
150-A&B
TR1-8-
151-A&B
TR1-8-
152-A&B
TR1-8-
153-A&B
TR1-8-
154-A&B
TR1-8-
155-A&B
TR1-8-
156-A&B
TR1-9-
157-A&B
TR1-9-
158-A&B
TR1-9-
159-A&B
TR1-9-
161-A&B
TR1-9-
160-A&B
TR1-9-
162-A&B
TR1-9-
163-A&B
TR1-9-
164-A&B
TR1-9-
165-A&B
TR1-9-
166-A&B
TR1-9-
167-A&B
TR1-9-
168-A&B
TR1-9-
169-A&B
TR1-9-
170-A&B
TR1-9-
171-A&B
TR1-9-
173-A&B
TR1-9-
172-A&B
TR1-9-174-A TR1-9-175-A TR1-9-176-A
TR1-9-177-A
TR1-9-178-A
TR1-9-179-A
TR1-9-180-A
233-1-1-A
233-1-2-A
233-1-3-A 233-1-4-A 233-1-5-A
233-1-6-A
233-1-7-A 233-1-8-A
233-2-9-A
233-2-10-A
233-2-11-A
233-2-12-A
233-2-13-A
233-2-14-A
233-2-15-A
233-2-16-A
233-3-17-A
TR1-9-181-A
TR1-9-182-A
TR1-9-183-A
TR1-9-184-A
TR1-9-185-A
TR1-9-186-A
TR1-9-187-A
J-HOOKS ON 2ND FLOOR
TYPICAL
C
TR1-9-188-A&B
TR1-9-189-A&B
TR1-9-190-A
TR1-9-191-A
SCALE: 1/8"=1'-0"
08 4
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A R
C H
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
A
2 3 4 5 6
B
C
D
E
PHASE -
M a rc h
W -1
-R
-6
-0
W -1
-C
-6
A B
C
PLAN NORTH
KEYPLAN
J .S
T
IP
E
T-507
S E
C O
N D
F L O
O R
R O
U T
IN
G
A N
D T
A G
G
IN
G P
L A
N
W R
A
IR
B U
IL
D
IN
G
L
IT
T L E
R O
C K
D
IS
T R
IC
T
L
IT
T L E
R O
C K
A
R K
A N
S A
S
B R
M
B R
M
C h e c k e r
1/8" = 1'-0"T-507
TELECOM SECOND FLOOR - OVERALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
P H
A S
E
S U
B M
IS
S
IO
N
/2
/1
C O
R R
E C
T E
D P
H A
S E
S
U B
M
IS
S
IO
N /1
/1 molokia JohnOneill_031417_seal
File details come from the government source that posted it.