29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf
PDF 478 KB Posted
- Attached to
- Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
- Solicitation number
- W9127S19Q6039
About this file
Part of Attachment I - As-Builts, 29-TPF North Public Health
View the file
Other files for this federal contract opportunity
Show all 50
Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SCALE: 3/16"=1'-0"
PLUMBING PLAN - D.W.V.
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L
E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I A
R C
H
IT
E C
T S
/3
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
S U
B M
IT
T
A L
C O
R R
E C
T E
D F
IN
A
L
J A
M E
S E
B
R A
D L
E Y
P
.E
J .L
.B
J .E
.B
J E
D U
N N
W
-1
-R -6
W
-1
-D -6
A S
I N
D
IC
A T
E D
THIRD PARTY:
& ASSOCIATES
HILBORN, WERNER, CARTER
1627 SOUTH MYRTLE AVE.
CLEARWATER, FLORIDA 33756
P L
U M
B
IN
G P
L A
N
D .W
.V
T Y
N D
A L
L A
F B
P U
B L
IC
H
E A
L T
H B
L D
G
TNP4.0
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
A B C i K MJ L N o P
MEDICAL
STANDARDS
OFFICE
(MSME)
PROVIDER
OFFICE
PHA
TECHNICIAN
WORKSTATION
PHA
TECHNICIAN
WORKSTATION
NURSE
WORKROOM
SOILED
UTILITY
NCOIC
OFFICE
SHPE OFFICE
INTERVIEW
PHA
INTERVIEW
ROOM
STAFF
TOILET
JANITOR'S
CLOSET
30 GAL
W/H
ELECTRICAL
ROOM
COMM
ROOM
PHA/DEPLOYMENT
MED/EXAM
ROOM
LPN
OFFICE
NCOIC
OFFICE
OIC
OFFICE
OPTOMETRIST
OFFICE
VISUAL
FIELD
OPTOMETRIST
OFFICE
SUB-WAITING
TOILET
COPY/FILE
DISTRORECEPTIONWAITING
VISUAL
SCREENING
MULTI-DIAGNOSTIC
ROOM
PUBLIC
HEATH
CENTER
AUDIO
TESTINGTECH
OFFICE /
INT OCC
HEALTH
EXAM
ROOM
EXAM
ROOM
IDMT
EXAM
ROOM
CLEAN
UTILITY
PROVIDER
OFFICE/OICY
PROVIDER
OFFICE
PROVIDER
OFFICE
TECHNOLOGY
OFFICE
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
TECH
TECH
IDMT
TECH
IDMT
TECH
EXAM
ROOM
EXAM
ROOM
EXAM
ROOM
TREATMENT
ROOM
MULTI-DIAGNOSTIC
ROOM
TECH
RECORD
FIXED
SHELVING
TECHNICIAN
OFFICE/INTERVIEW
COMMUNITY
HEALTH
COPY/FILE
DISTRO
DEPLOYMENT
MED OFFICE
COUNSELING
ROOM
TECHNICIAN
OFFICE/INTERVIEW
COMMUNITY
HEALTH
AUDIO
TESTING
FULL
EYE-LANE
FULL
EYE-LANE
FRAMES
CONTACTS
STORAGE
FOLDED
EYE-LANE
FOLDED
EYE-LANE
FITTING
DISPENSING
AREA
I/ D
U N
IT
O/D UNIT
MULTI-DIAGNOSTIC
ROOM
WAITING
RECEPTION RECEPTION
COPY/FILE
DISTRO
STORAGE
STAFF
TOILET
PHA
INTERVIEW
ROOM
PHA
INTERVIEW
ROOM
WAITING
TECH
WORKSTATION
D E F G H
D R
A
IN
3" DRAIN
D R
A
IN
4" DRAIN
/2
D R
A
IN 1 1/2"VTR
3"VTR
1 1/2"VTR
3"C.O.
4"C.O.
1 1/2"VTR
/2
D R
A
IN
4" DRAIN
/2
D R
A
IN
1 1/2"VTR 1 1/2"VTR
2"B.V.
3"VTR
F.D. F.D.
D R
A
IN
4" DRAIN3" DRAIN3" DRAIN3" DRAIN3" DRAIN3" DRAIN
/2
D R
A
IN
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
/2
D R
A
IN
3"C.O.
2"VTR
1 1/2"VTR
1 1/2"VTR
1 1/2"VTR1 1/2"VTR
1 1/2"VTR1 1/2"VTR1 1/2"VTR
1 1/2"VTR
1 1/2"VTR
1 1/2"A.V.
1 1/2"VTR
REFERENCE UTILITY
PLAN 1-CU1.01 FOR
ADDITIONAL WASTE
PIPING INFORMATION
January 27, 2017
VALID
tracbr Text Box Amendment 1 tracbr Rectangle tracbr Text Box 3/15/2017 tim.kitchens Snapshot
File details come from the government source that posted it.