29_03_TNP1.0_Plumbing_Schematics.pdf
PDF 550 KB Posted
- Attached to
- Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
- Solicitation number
- W9127S19Q6039
About this file
Part of Attachment I - As-Builts, 29-TPF North Public Health
View the file
Other files for this federal contract opportunity
Show all 50
Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
(C E
P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N (C
E P
M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L E
D E
S
IG
N T
E A
M C
E P
M
/2
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
W -1
-R
-6
C O
N T
R A
C T
N U
M B
E R
W -1
-D
-6
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O E F E R W Y S O C K I
A R C H
IT
E C T S
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL - NORTH
PUBLIC HEALTH BLDG
S U
B M
IT
T
A L
C O
R R
E C
T E
D F
IN
A
L
J A
M E
S E
B
R A
D L E
Y P
.E
J .L
.B
J .E
.B
J E
D U
N N
A S
I N
D
IC
A T
E D
P L U
M B
IN
G
S C
H E
M A
T
IC
S
T Y
N D
A L L A
F B
P U
B L
IC
H E
A L T
H B
L D
G
TNP1.0
M
A G
N O
L
IA
C
IR
C L E
T Y
N D
A L L
A F
B
F L
S y m b o l
D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
SUPPLY LINE NOTES:
1. SUPPLY LINE SIZING IS BASED ON AN ASSUMED AVAILABLE PRESSURE OF
60 PSI AT THE LOCATION OF THE INLET(S) SHOWN AFTER ANY DEDUCTIONS
FOR PRESSURE LOSS DUE TO METER, TAP INTO MAIN, WATER PRESSURE
REDUCING VALVES, SPECIAL EQUIPMENT SUCH AS BACKFLOW PREVENTOR,
FILTER, SOFTENER, ETC. THIS AVAILABLE PRESSURE MUST BE VERIFIED
PRIOR TO CONSTRUCTION. IF A BOOSTER PUMP IS NEEDED TO ACHIEVE
REQUIRED PRESSURE THEN THE BUILDING OWNER IS RESPONSIBLE FOR
DESIGN AND INSTALLATION OF PUMP SYSTEM.
2. SUPPLY LINE INLET(S) SHOWN ON THESE PLANS ARE ASSUMED TO
EXTEND ONLY TO EXTERIOR WALL. ALL SERVICE SUPPLY LINES UP TO THE
INLET(S) ARE DESIGNED BY OTHERS AND SITE INSTALLED UNLESS
OTHERWISE SPECIFIED.
3. SUPPLY LINE SIZING MUST BE REDESIGNED IF THE BUILDING DOES NOT
COMPLY WITH ANY OF THE ABOVE ASSUMPTIONS.
4. UNLESS OTHERWISE SPECIFIED ALL SUPPLY LINES ARE 1"Ø MINIMUM TO
FLUSHOMETER VALVE WATER CLOSETS AND 3/4"Ø MINIMUM TO ALL
OTHER FIXTURES. UNLESS OTHERWISE SPECIFIED ALL STUB-UPS ARE 1"Ø TO
FLUSHOMETER WATER CLOSETS, 3/4"Ø TO FLUSH VALVE URINALS AND
1/2"Ø TO ALL OTHER FIXTURES.
5. EACH URINAL SHALL NOT REQUIRE MORE THAN 15 PSI OF PRESSURE (12
GPM) TO ACTIVATE THE FLUSHOMETER VALVE.
6. EACH WATER CLOSET SHALL NOT REQUIRE MORE THAN 25 PSI OF
PRESSURE (25 GPM) TO ACTIVATE THE FLUSHOMETER VALVE.60 PSI AT MAIN INLET AND SHOULD BE VERIFIED
AN ASSUMED AVAILABLE PRESSURE OF 46 TO
SPECIFIED. SUPPLY LINE SIZING IS BASED ON
PRIOR TO CONSTURCTION.
STUB-UPS SHALL BE 1/2" UNLESS OTHERWISE
ALL SUPPLY LINES SHALL BE 3/4" AND ALL
SUPPLY RISER
COLD
HOT
SCALE: N.T.S.
MODULE
PERIMETER
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE
MATELINE
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
MODULE A
MODULE B
MODULE C
MODULE D
MODULE E
MODULE F
MODULE G
MODULE H
MODULE I
MODULE J
MODULE K
MODULE L
MODULE M
MODULE N
MODULE O
MODULE P
SINK
SINK
LAV
LAV
LAV
WC
LAV
WC
LAV
LAV
LAV
LAV
LAV
LAV
LAV
MOP
SINK
LAV
LAV
1/2"
/2
"1 /2
3/4"
/2
"1 /2
VALVE
T&P
30 GAL.
W/H
1"
A-112
1"
"1
1"
1" 1/2"
SINK
1/2"
/2
"1 /2
1/2"
1/2"
1/2"
3/4"
3/4"
1/2" 1/2"
LAV
LAV 3/4"
3/4"
1/2" 1/2"
LAV
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
3/4"
WF
1/2"
1"
1"
1"
1" 3/4"
3/4"
3/4"
1"
1"
1/2"
/2
"1 /2
1/2"
/2
"1 /2
/2
"1 /2
1/2"
1/2"
1/2"
1/2"
1/2"
1/2"
1"
1 1/4"
1 1/4"
1"
3/4"
1/2"
1/2"
/2
/2
/2
WC
/2
/2
1 1/4"
1 1/4"
1 1/4"
1 1/4"
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
" 1 /2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
/2
F.D.
w/T.P.
F.D.
w/T.P.
F.D.
w/T.P.
F.D.
w/T.P.
REFERENCE TPF-5.0
FOR OVERALL WASTE
PIPING ISOMETRIC
1"
1"
1"
1"
1"
3/4"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1/2"
3/4"
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
FLOW
HOT RETURN
42" min.
T
O C
T R
R O
LL
to p
6" max
42" min. 12" m a x.
m in m a x.
t o m in m a x ce n te r
C O
N T
R O
L
D
IS
P E
N
SE
39"-41" m in
18"
Se a t max.
15" min
/2 m in
24" min
42" max to p
/2 m a x
15" MIN.
M
IN
M
IN
6" MAX.8" MIN.
M
A X
T
O O
R
IF
IC
E
T O
O R
IF
IC
E
5" MAX.
HI/LOW DRINKING
FOUNTAIN
15" MIN.
1 1/4" to 1 1/2" MAX.
DIA. S.S. GRAB BARS
FLUSH HANDLE
LOCATED ON
ACCESSIBLE SIDE
OF TOILET
MIN. 1 1/2" GAP BETWEEN
TANK AND GRAB BAR
PROTRUDING TOILET
PAPER DISPENSER
H.C. ACCESSIBLE ELONGATED
TOILET w/SPLIT-FRONT TYPE
SEAT
1 1/4" to 1 1/2" MAX.
DIA. S.S. GRAB BARS
ALL EXPOSED PIPES INCLUDING DRAIN
MUST BE INSULATED WITH LAVATORY
GUARD BY TRUEBRO OR AN
APPROVED EQUAL
MIRROR
H.C. APPROVED
LEVER FAUCET
PAPER TOWEL
DISPENSER
SCALE: 1/2"=1'-0"
RESTROOM (TOILET) PLUMBING FIXTURE ELEVATIONS
SCALE: 1/2"=1'-0"
HI/LOW DRINKING FOUNTAIN ELEVATIONS
A
TNP1.0
B
TNP1.0
RE: TLV2.0 FOR NURSE
CALL LOCATION
P D
F c re a te d w it h p d fF a c to ry t ri a l v e rs io n w w w
.p d ff a c to ry .c o m tim.kitchens Snapshot tim.kitchens Rectangle tim.kitchens Rectangle
File details come from the government source that posted it.