SCALE: 3/16"=1'-0"
FLOOR PLAN - PHASE 2
FIRE EXTINGUISHER - 10# 2-A:10-B:C IN RECESSED CABINET
(2) 2x4 SPF #2 THIS HALF
(3) 2x4 SPF #2 THIS HALF
(2) 2x6 SPF #2 THIS HALF
(4) 2x4 SPF #2 THIS HALF
PER APPROVED PACKAGE
COLUMN STRAPPING SCHEDULE
INSTALL TWO STEEL STRAPS AT EACH STUD OF EACH COLUMN.
ALL COLUMN STUDS SHALL BE GLUE/NAILED TOGETHER.
COLUMN STUDS SHALL NOT BE NOTCHED OR BORED.
PVA GLUE WITH 100% COVERAGE SHALL BE USED.
ADD RIDGE BEAM BEARING STIFFENER
STRUCTURAL HEADER ABOVE OPENING
NOTES:
1.
3.
2.
E
G
C
A
(3) 2x4 SPF #2 EACH HALF
(2) 2x4 SPF #2 EACH HALF
(2) 2x6 SPF #2 EACH HALF
(4) 2x4 SPF #2 EACH HALFF
H
D
B
(3) 2x6 SPF #2 THIS HALFJ (3) 2x6 SPF #2 EACH HALFK
A
54321
B
C
D
E
B A
S E
C
IV
IL
E
N G
IN
E
E R
/D E
P U
T Y
C H
IE
F
E N
G
IN
E E
R
IN
G F
L
IG
H T
C
E P
C H
IE
F
C O
N T
R A
C T
S S
E C
T
IO
N
C E
P M
R E
C O
M M
E N
D E
D
R E
C O
M M
E N
D E
D
A P
P R
O V
E D
R E
V D
A T
E E
N G
IN
E
E R
\D E
S
IG
N E
R
D R
A W
N B
Y
S C
A L
E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
C O
N T
R A
C T
N U
M B
E R
D E
S
IG
N T
E A
M C
E P
M
U S
IN
G
A G
E N
C Y
C H
E C
K E
D B
Y
H O
E F
E R
W Y
S O
C K
I A
R C
H
IT
E C
T S
3/
/2
JE DUNN + HWA
CLEARWATER, FL 33756
CONSULTING ENGINEER
1765 CARNEGIE AVENUE
Ph: (727) 505-9941
JAMES E. BRADLEY, P.E.
J E B
0' 4' 8' 16' 32'
1/8" = 1'-0"
0' 2' 4' 8' 16'
1/4" = 1'-0"
0' 1' 2'
3/4" = 1'-0"
4'0' 1'
1 1/2" = 1'-0"
2' 2'1'6"6"3"0' 6"
3" = 1'-0"
1'3"
2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930
TPF TYNDALL - SOUTH
AMBULANCE SERVICES BLDG
A S
I N
D
IC
A T
E D
J A
M E
S E
B
R A
D L
E Y
P
.E
W
-1
-R -6
W
-1
-D -6
J .L
.B
J E
D U
N N
J .E
.B
S U
B M
IT
T
A L
C O
R R
E C
T E
D F
IN
A
L A
M E
N D
M E
N T
& ASSOCIATES
HILBORN, WERNER, CARTER
1627 SOUTH MYRTLE AVE.
CLEARWATER, FLORIDA 33756
THIRD PARTY:
F L
O O
R P
L A
N
P H
A S
E
T Y
N D
A L
L A
F B
A M
B U
L A
N C
E S
E R
V
IC
E S
B L
D G
TSA
2.0-PII
M
A G
N O
L
IA
C
IR
C L
E T
Y N
D A
L L
A F
B
F L
S y m b o l D es cr ip ti o n
T ra ck in g N o
A ct io n
D at e
1 HOUR
FIRE
50 STC
SOUND
GENERIC
WALLS AND INTERIOR PARTITIONS, WOOD-FRAMED
GYPSUM WALLBOARD, WOOD STUDS
ONE LAYER 5/8" TYPE X PLAIN OR PREDECORATED GYPSUM WALLBOARD,
WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE
APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2 X 4 WOOD
STUDS 16" O.C.; JOINTS OF SQUARE EDGE, BEVEL EDGE OR PREDECORATED
WALLBOARD MAY BE LEFT EXPOSED. NOTE: ONE SIDE OF WALL MUST HAVE
RC-1 CHANNELS
JOINTS STAGGERED 16" ON OPPOSITE SIDES. (LOAD-BEARING)
Thickness: 5 1/4"
Approx. Weight: 7 psf
Fire Test: UL R1319-4, -6, 6-17-52;
UL R2717-39, 1-20-66;
UL R3501-52, 3-15-66,
UL Design U305;
ULC Design W301
Sound Test: OR 64-8, 2-4-64
GA FILE NO. WP 3605
UL DESIGN U305
50 STC SOUND
w/BATT INSULATION
AND RC-1 CHANNELS
1 HOUR
FIRE
34 to 46 STC
SOUND
GENERIC
WALLS AND INTERIOR PARTITIONS, WOOD-FRAMED
GYPSUM WALLBOARD, WOOD STUDS
ONE LAYER 5/8" TYPE X PLAIN OR PREDECORATED GYPSUM WALLBOARD,
WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE
APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2 X 4 WOOD
STUDS 16" O.C.; JOINTS OF SQUARE EDGE, BEVEL EDGE OR PREDECORATED
WALLBOARD MAY BE LEFT EXPOSED.
JOINTS STAGGERED 16" ON OPPOSITE SIDES. (LOAD-BEARING) Thickness: 4 7/8"
Approx. Weight: 7 psf
Fire Test: UL R1319-4, -6, 6-17-52;
UL R2717-39, 1-20-66;
UL R3501-52, 3-15-66,
UL Design U305;
ULC Design W301
Sound Test: OR 64-8, 2-4-64
GA FILE NO. WP 3605
UL DESIGN U305
46 STC SOUND w/BATT
INSULATION
DOOR SCHEDULE
# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS
36"x80" EXT DOOR - STEEL - FLUSH 2 TRPL 2x4 1 1 w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPINGA
37 SNGL 2x4 - 1
B
WINDOW SCHEDULE
# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS
EXT WINDOW - SNGL HUNG - VERT SLIDING 4 TRPL 2x4 1 1
VINYL WHITE FRAME / DIG TINTED LOW-E GLASS w/ROLLER SHADES1
36"x80" INT. DOOR - SOLD CORE - FLUSH w/STEEL FRAME, KEYED LEVER LOCKSET
6 SNGL 2x4 - 1
C
36"x80" w/STEEL FRAME, PRIVACY LEVER LOCKSET
D
36"x60"
INT. DOOR - SOLD CORE - FLUSH
EXT WINDOW - SNGL HUNG - VERT SLIDING 4 TRPL 2x4 - 1
VINYL WHITE FRAME / DIG TINTED LOW-E GLASS w/ROLLER SHADES2
24"x60"
INT WINDOW - HORZ SLIDING - RECEPTIONIST 2 SNGL 2x4 - 1
MILL/CLEAR3
BOTTOM OF WINDOW
AT 34" A.F.F.
60"x36"
48"x80" EXT DOOR - STEEL - FLUSH 1 TRPL 2x6 1 1 w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPING
1 TRPL 2x4 1 136"x80" w/STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPINGE
EXT DOOR - STEEL - FLUSH -
2 SNGL 2x448"x80" w/STEEL FRAME, KEYED LEVER LOCKSETF
INT. DOOR - SOLD CORE - FLUSH
2 SNGL 2x4 - 136"x80" INT. DOOR - SOLD CORE - FLUSH w/STEEL FRAME, PUSH/PULL, CLOSERG
WALL MOUNTED MINI-SPLIT
A/C UNIT; (COOLING ONLY)
FREDRICH (350 CFM); BOTTOM
OF UNIT TO BE AT 80" A.F.F.
OUTDOOR CONDENSING UNT; FREDRICH
#MR12CH; OUTSIDE CONDENSING UNIT
(12,300 BTUH COOLING ONLY); ALL
CONDENSATE LINES AND WIRING TO
INDOOR UNITS ARE TO BE SITE
INSTALLED BY SMM; UNIT IS SHIPPED
LOOSE AND SITE INSTALLED
DN
LINE PLENUM WALL WITH
MIN. 1/2" GYPSUM, TYP.
3/0x5/0VS
11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"
6"
11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"
3'-10"
11'-2"
186'-8"
A B C D E F G H i J K L M N o P
4/0x6/8
3/0x6/8
/0 x6 /8
3/0x6/8
/0 x6 /8
3/0x6/8
3/0x6/8
/0 x6 /8
3/0x6/83/0x6/8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
3/0x6/8
3/0x6/8
42"G.B.
"G .B
"V .G
.B
"G .B
36"G.B.
18"V.G.B.
/0 x6 /8
3/0x6/8
3/0x6/8
3/0x6/8
/0 x6 /8
/0 x6 /8
3/0x6/8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
/0 x6 /8
3/0x6/8 3/0x6/8
3/0x6/8
/0 x6 /8
/0 x6 /8
STORAGE
12'-8" 8'-0"7'-0" 14'-6" 5'-0" 19'-7"
3/0x6/8
10'-0" 10'-0" 9'-5"
10'-10"23'-8"29'-4"5'-10"5'-0"9'-9"9'-11"10'-0"10'-0"14'-4"5'-0"16'-8"
5'-0"
5'-0"
10'-10"
12'-0"
7'-4" 9'-8" 13'-4"
18'-0" 5'-0" 12'-0"
14'-6"
9'-8"
25'-10"5'-0"
14'-4"
7'-4" 10'-6" 5'-0"
23'-4"10'-0"
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
36" OPENING
FOR REFRIG
ICE MAKER
CONNECTION
W3030
B30SB36
W3615
NCO
OFFICE
(SHARED)
PERSONAL
PROPERTY
LOCKERS
PATIENT
TOILET
"G .B
36"G.B.
18"V.G.B.
STAFF
TOILET JANITOR'S
CLOSET
MOP
SINK
30 GAL
W/H
STAFF
LOUNGE /
CONFERENCE
ROOM
WAITING
COMM
ROOM
SHIPPING/
RECEIVING
TECHNICAL
SUPERVISOR
SHARED
NCOIC
OFFICE
OIC
OFFICE
CENTRAL
STORAGE
M/TLT
MICRO
BIOLOGY
JANITOR
MOP
SINK
30 GAL
W/H
F/TLT
SPECIMEN
TOILET
WAITING
RECEPTION
COPY/FILE
DISTRO
TECH
TECH
BLOOD
DRAW AREA
CORE
LAB
STAFF
LOUNGE/TEAM
CONFERENCE
ROOM
/0 x5 /0
V S
/0 x5 /0
V S
/0 x5 /0
V S
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
2/0x5/0VS
11" 3'-4"
4" 4" 4" 4" 4" 4"
6"
/2
11'-2"6"
LINE PLENUM WALL WITH
MIN. 1/2" GYPSUM, TYP.
LINE PLENUM WALL WITH
MIN. 1/2" GYPSUM, TYP.
PANEL "A"
150 AMP
120/208v, 1Ø
F
PANEL "B"
150 AMP
120/208v, 1Ø
PANEL "C"
150 AMP
120/208v, 1Ø
PANEL "D"
150 AMP
120/208v, 1Ø
PANEL "E"
150 AMP
120/208v, 1Ø
PANEL "F"
150 AMP
120/208v, 1Ø
PANEL "G"
150 AMP
120/208v, 1Ø
PANEL "H"
150 AMP
120/208v, 1Ø
PANEL "i"
150 AMP
120/208v, 1Ø
PANEL "J"
150 AMP
120/208v, 1Ø
PANEL "K"
150 AMP
120/208v, 1Ø PANEL "L"
150 AMP
120/208v, 1Ø
PANEL "M"
150 AMP
120/208v, 1Ø
PANEL "N"
150 AMP
120/208v, 1Ø
PANEL "o"
150 AMP
120/208v, 1Ø
PANEL "P"
150 AMP
120/208v, 1Ø
B B
B
F
D
HK
A
E
EB
C
C
C
DD
C
C
CC
C
C
C
C
D
C
C
C
C
C
D
C G
C
C
C
H
3'-0"
11'-4"
F.D.
w/T.P.
1 1/2"VTR
3"VTR
3"VTR
P
LU
M B
W A
LL
F.D.
w/T.P.
B
B
B
D
D
B
7'-10"
2'-6"
3'-4" 7'-0"
3'-4"
3'-0"
C
F
B
C
B
B B
5'-2"
F
H J
1'-0"
F F
F
B
F
EXERCISE
AREA
F
B B
6'-0"8'-6"
6'-0"8'-6"
B
B
B
B
H
B
B
6'-0"8'-6"
6'-0"8'-6"
1'-7"
4" 4"
B
B
B
2"B.V.
P
LU
M B
W A
LL
1'-0"
H H H HB B B
F.D.
w/T.P.
D
D
D
D
5'-8"
D
D
D
D
D D
D
B
B
B
B
B
B
B
B
B
B
B
B B
D
F.D.
w/T.P.
D
5'-4"3'-2"4'-6"
8'-8"1'-0"10'-0"
F
B-102
82.50 SF
V.C.T.
B-104
343.75 SF
V.C.T.
B-101
94.50 SF
CARPET
S-102
126.67 SF
CARPET
V.C.T.
V.C.T.
G-109a
63.89 SF
V.R.G.
G-109b
46.67 SF
V.R.G.
A-107
61.83 SF
V.R.G.
G-108
35.00 SF
V.R.G.
A-106
114.67 SF
V.C.T.
G-107
80.00 SF
CARPET
G-106
80.00 SF
CARPET
G-101
153.75 SF
V.C.T.
G-103
565.76 SF
V.C.T.
G-103
556.28 SF
V.C.T.
A-101
145.00 SF
CARPET
A-102
145.00 SF
V.C.T.
G-105
166.75 SF
V.C.T.
G-104
166.75 SF
V.C.T.
A-105
170.00 SF
V.C.T.
A-104
60.00 SF
V.R.G.
A-103
170.00 SF
V.C.T.
K-107
164.33 SF
V.C.T.
K-103
314.33 SF
V.C.T.
K-104
108.00 SF
V.C.T.
K-104a
108.00 SF
V.C.T.
K-101
279.00 SF
V.C.T.
K-102
52.50 SF
V.R.G.
K-108
225.50 SF
V.C.T.
K-109
102.00 SF
CARPET
K-111
106.72 SF
CARPETK-112
151.67 SF
V.C.T.
P-106
520.67 SF
CARPET
113.34 SF
CARPET
K-105a
106.67 SF
V.C.T.
K-105
735.00 SF
V.C.T.
P-101
195.00 SF
V.C.T.
A-108
281.64 SF
V.C.T.
V.C.T.
V.C.T.
V.C.T.
V.C.T.
P-102
98.82 SF
CARPET
P-103
140.83 SF
CARPET
V.C.T.
V.C.T.
V.C.T.
A
EXIT B
W.P.
w/P.C.
EXIT B
W.P.
w/P.C.
EXIT B
EXIT BEXIT BEXIT BEXIT B
W.P.
w/P.C.
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
15'-8"
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
60"x12"(D) LAMINATED
COUNTER AT 34" A.F.F.
FLOORS:
NOTE: FLOOR JOISTS IN
UNITS "G & H" FROM 32'-0"
TO 40'-0" TO BE 12" O.C.
EXIT B
EXIT B
EXIT B
(2) 2" CONDUITS
UP THRU FLOOR
I/D UNIT
O/D UNIT
2"VTR
1 1/2"A.V.
/0 x6 /8
42"G.B.
"G .B
"V .G
.B
STAFF
TOILET
D6
P
LU
M B
W A
LL
2"VTR
F.D.
w/T.P.
B-103
61.83 SF
V.R.G.
/0 x6
/8
F
3/0x6/8
C
ON-CALL
ROOM
B-105
66.00 SF
V.C.T.
8'-10"
/0 x6 /8
C
KITCHEN
B-104a
42"G.B.
"G .B
"V .G
.B
"24"
DOOR
"24"
DOOR
2"B.V.
F.D.
w/T.P.
3"VTR
36"
DOOR
P
LU
M B
W A
LL
42"G.B.
"G .B
"V .G
.B
2"B.V.
F.D.
w/T.P.
3"VTR
36"
DOOR
K-105b
42"G.B.
"G .B
"V .G
.B
MOP
SINK
STAFF
TOILET
"V
T R
F.D.
w/T.P.
1 1/2"VTR
JANITOR
A-106
38.50 SF
V.R.G.
K-106
30.00 SF
V.R.G.
F.D.
w/T.P.
H
3/0x6/8
C
P
LU
M B
W A
LL
/0 x6 /8
C
SITE INSTALLED CORRIDORSITE INSTALLED CORRIDORSITE INSTALLED CORRIDORSITE INSTALLED CORRIDOR
/2 "V
T R
/0 x6 /8
C
A A1.0
B A1.0
D A1.0 A1.0
3/0x6/8
/0 x6 /8
D
6'-4"2'-6"
9'-10"
4'-7"
P
LU
M B
W A
LL
5'-0"
/0 x6 /8 C
P-105
75.83 SF
V.C.T.
3/0x6/8
C
A-646
110.00 SF
CARPET
C
D
3/0x6/8
C
C
8'-8"
G-107
118.08 SF
V.C.T.
"G .B
36"G.B.
18"V.G.B.
F.D.
w/T.P.
PATIENT
TOILET
3"VTR
1 1/2"VTR
27'-0"
28'-10"
12'-0" 6
B
3'-5"
/2
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
(4
LA
Y
E R
/4 x
P
LY
W
O O
D
HSMR
STORAGE
30'-10"
1'-10"
STORAGE
9'-8"
/0 x6 /8
C
3/0x6/8
C 2'-10"2'-6" 4'-5"
747.40 SF
V.C.T.2
26'-4"
31'-2"
168.42 SF
V.C.T.
FIT
170.00 SF
V.C.T.
LIBRARY
79.33 SF
V.C.T.
3/0x6/8
C
OFFICEOFFICE
STORAGE
BEE
WORK ROOM
OFFICE
LAB
VACANTVACANT
BMET
VACANT
VACANT
VACANT
VACANT
VACANT
/0 x6 /8
C
DN
DN
B
B
B
36" OPENING
FOR REFRIG
ICE MAKER
CONNECTION
W3030
B30 SB36
W3615 W1830
B18
1 1/2"VTR
30 GAL
W/H
ACCESS
36"x48"
3/0x6/8
C
5'-7" 4'-0" 2'-1"
NON-STRUCT
HEADER; SITE
INSTALL DOOR
7'-4"
M
IN
3'-2"
3'-10" 4'-11" 4'-11"
3'-4"
3/0x6/8
17'-0"
11'-8"
B
6'-6"
ACCESS
36"x48"
5'-0"4'-8"
/0 x6 /8
10'-0"
G
SB36B36
1 1/2"VTR
D-4
+72" A.F.F.
J
E-4
SB30
1 1/2"A.V.
WALL MOUNTED
BABY CHANING
STATION, TYP. of (2)
2'-6"
2'-10"
13'-0"
2"VTR
F.D.
w/T.P.
2"B.V.
2"B.V.
1 1/2"VTR
EYEWASH
STATION TO BE
ADDED TO SINK
B
D
CANOPY
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
SEE TCCA2.0 FOR
ADDITIONAL DETAILS
SEE TCCA2.0 FOR
ADDITIONAL DETAILS
NOTE: DO NOT INSTALL
REMOTE HEADS IN CORRIDOR
INSTALL PLATES, TYP.
C
5'-0"
3/0x6/8
C
ON-CALL
ROOM
B-106
66.00 SF
V.C.T.
8'-10"
C
TSA2.1
B
TSA2.1
A
TSA2.1
D
TSA2.1
E
TSA2.1
E
TSA2.1
E
TSA2.1
F
TSA2.1
H
TSA2.1
G
TSA2.1
J
TSA2.1
K
TSA2.1
M
TSA2.1
L
TSA2.1
N
TSA2.1
P
TSA2.1
E
TSA2.1
Q
TSA2.1
R
TSA2.1
DN
3'-0"
S
IN
K
SINK S
IN
K
1 1/2"ISLAND
VENT
2"VTR
D-4
D-4
5'-0"
NOTE: CORE LAB FLOOR DEFLECTION
"L/240" TO BE LESS THAN 1/8 INCH
M
IN
/2 "V
T R
M
IN
18"
MIN.
10"
B U
LK
H
E A
D
B U
LK
H
E A
D
BULKHEAD
B U
LK
H
E A
D
B U
LK
H
E A
D
B U
LK
H
E A
D
D-4
STAINLESS STEEL
WALL MOUNTED
HAND SINK
5'-1"
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED
PER MFG'R SPEC'S w/7.5 kW HEAT
STRIP; 850 CFM @ .4 IWC ESP
w/DEHUMIDIFIER AND C.R.V. (50%
FRESH AIR INTAKE); 208v 1Ø; w/2
INCH MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP;
1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE AND DEHUMIDIFIER ; 208v
1Ø; w/2 INCH MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED
PER MFG'R SPEC'S w/7.5 kW HEAT
STRIP; 1000 CFM @ .4 IWC ESP
w/25% FRESH AIR INTAKE; 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 850
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
3.5 TON WALL HUNG HVAC UNIT
(MD#:W42A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1200
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT (MD#:W30A2-A10XP)
INSTALLED PER MFG'R SPEC'S w/7.5 kW HEAT STRIP;
850 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE; 208v
1Ø; w/2 INCH MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT (MD#:W36A2-A10XP)
INSTALLED PER MFG'R SPEC'S w/7.5 kW HEAT STRIP;
1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE;
208v 1Ø; w/2 INCH MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP;
1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE AND DEHUMIDIFIER ; 208v
1Ø; w/2 INCH MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP;
850 CFM @ .4 IWC ESP w/25% FRESH
AIR INTAKE; 208v 1Ø; w/2 INCH
MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 850
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
2.5 TON WALL HUNG HVAC UNIT
(MD#:W30A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP;
850 CFM @ .4 IWC ESP w/25% FRESH
AIR INTAKE; 208v 1Ø; w/2 INCH
MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
3.0 TON WALL HUNG HVAC UNIT
(MD#:W36A2-A10XP) INSTALLED PER
MFG'R SPEC'S w/7.5 kW HEAT STRIP; 1000
CFM @ .4 IWC ESP w/DEHUMIDIFIER AND
C.R.V. (50% FRESH AIR INTAKE); 208v 1Ø;
w/2 INCH MERV-8 PLEATED FILTER
/0 x6 /8
C
F.D.
w/T.P.
EMERGENCY DRENCH
SHOWER/EYEWASH STATION
A-5 B-5 B-5 tim.kitchens Snapshot