29_02_TNA2.0_Floor_Plan.pdf

PDF 3 MB Posted

Attached to
Tyndall AFB Temporary Modular Medical Facility Federal contract opportunity
Solicitation number
W9127S19Q6039
Issued by
Department of the Army Corps of Engineers Engineering District Little Rock

About this file

Part of Attachment I - As-Builts, 29-TPF North Public Health

View the file

Other files for this federal contract opportunity

Other files attached to Tyndall AFB Temporary Modular Medical Facility, newest first.
File Type Posted
55_TQ4.11D_-_FFE_PLAN_-_TPF_PHASE_2,_AREA_D.pdf PDF
49_23__TCP1.5_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV2.0_STANDARD_RAMP_AND_STAIR_DETAILS_STAMPED.pdf PDF
49_24__TPF2.0-PI_Full_Building_Plan-Phase_1.pdf PDF
1-V1.01_SURVEY_PLAN.pdf PDF
49_23__TCP1.3_Combined_Clinic_TPF_RCP.pdf PDF
55_TQ4.01_-_FFE_JSN_LEGEND.pdf PDF
1-V1.05_SURVEY_PLAN.pdf PDF
49_21__TFP3.3_Combined_Clinic_TPF_Fire_Suppression_Notes_and_Details.pdf PDF
49_21__TFP4.3_Combined_Clinic_TPF_Fire_Alarm_Details_and_Notes.pdf PDF
55_TQ3.11A_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_A.pdf PDF
1-V1.07_SURVEY_PLAN.pdf PDF
1-V1.02_SURVEY_PLAN.pdf PDF
49_24__TPF2.0_Full_Building_Plan.pdf PDF
49_23__TCP1.4-PII_Combined_Clinic_TPF_RCP-PHASE_II.PDF PDF
1-V1.06_SURVEY_PLAN.pdf PDF
49_24__TPF6.0_Overall_Plumbing_Plan_-_Supply.pdf PDF
49_21__TFP3.1_Combined_Clinic_TPF_Fire_Suppression_Plan_Phase_1.pdf PDF
49_23__TCP1.1_Combined_Clinic_TPF_RCP.pdf PDF
49_25__TPFV1.0_COVER_SHEET_STAMPED.pdf PDF
49_25__TPFV8.0_CANOPY_ASSEMBLY_AND_FOOTING_DETAILS_STAMPED.pdf PDF
55_TQ3.11D_-_FFE_PLAN_-_TPF_PHASE_1,_AREA_D.pdf PDF
36_10_TSP2.0_Plumbing_Schematics.pdf PDF
29_02_TNA3.0_Reflective_Ceiling_Plan.pdf PDF
36_14_TSFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE4.0_MDP_-_One_Line_Diagram.pdf PDF
36_09_TSA3.0-PII_Reflective_Ceiling_Plan.pdf PDF
29_04_TNE1.0_Elec_Plan.pdf PDF
36_12_TSM1.0-PII_Mechanical_HVAC_Plan.pdf PDF
43_16_TCCA2.0_Floor_Plan.pdf PDF
36_10_TSP4.0_Plumbing_Plan_-_DWV_Phase_1.pdf PDF
36_11_TSE1.0-PII_Electrical_Plan.pdf PDF
36_09_TSA2.1_Interior_Elevations.pdf PDF
29_02_TNA1.0_Exterior_Elevations.pdf PDF
43_16_TCCA3.0_Reflective_Ceiling_Plan.pdf PDF
36_09_TSA2.0-PII_Floor_Plan_-_Phase_2.pdf PDF
36_12_TSM1.0_Mechanical_HVAC_Plan.pdf PDF
29_03_TNP4.0_Plumbing_Plan_-_DWV.pdf PDF
29_01_TNC1.0_Cover_Sheet-Notes.pdf PDF
29_03_TNP1.0_Plumbing_Schematics.pdf PDF
43_19_TCCX2.0_Roof_Drain_Details.pdf PDF
43_19_TCCX1.0_Building_Cross_Section.pdf PDF
29_07_TNFD1.0_Foundation_Plan_and_Details.pdf PDF
36_11_TSE1.1_Electrical_Panel_Schedules.pdf PDF
36_10_TSP3.0_Plumbing_Plan_-_Supply_Phase_1.pdf PDF
W9127S19Q6039_Tyndall_TMMF_Combined_Synopsis_Solicitation_13Aug19.pdf PDF
Tyndall_TMMF_Statement_of_Work_13Aug19.pdf PDF
Attachment_F_-_Codes_&_Criteria.pdf PDF
Attachment_D_-_DHA_LAN_WLAN_Guides.pdf PDF
Attachment_A_-_Siting_&_Parking.pdf PDF
Show all 50

Tyndall AFB Temporary Modular Medical Facility has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 3/16"=1'-0"

FLOOR PLAN

DOOR SCHEDULE

# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS

36"x80" EXT DOOR - STEEL - FLUSH 1 TRPL 2x4 1 1 w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPINGA

50 SNGL 2x4 - 1

B

WINDOW SCHEDULE

# SIZE DESCRIPTION QTY HEADER JACKS KINGS COMMENTS

EXT WINDOW - SNGL HUNG - VERT SLIDING 6 TRPL 2x4 1 1

VINYL WHITE FRAME / DIG TINTED LOW-E GLASS w/ROLLER SHADES1

36"x80" INT. DOOR - SOLD CORE - FLUSH w/STEEL FRAME, KEYED LEVER LOCKSET

3 SNGL 2x4 - 1

C 36"x80" w/STEEL FRAME, PRIVACY LEVER LOCKSET

SOUND GASKET; STC 47

RATED DOOR

1 TRPL 2x6 1 2

D 72"x80" EXT DOOR - STEEL - FLUSH w/20"x30" SAFETY GLASS VIEW PANEL, STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPING

36"x60"

INT. DOOR - SOLD CORE - FLUSH

EXT WINDOW - SNGL HUNG - VERT SLIDING 6 TRPL 2x4 - 1

VINYL WHITE FRAME / DIG TINTED LOW-E GLASS w/ROLLER SHADES2

24"x60"

INT WINDOW - HORZ SLIDING - RECEPTIONIST 3 SNGL 2x4 - 1

MILL/CLEAR3

BOTTOM OF WINDOW

AT 34" A.F.F.

60"x36"

(2) 2x4 SPF #2 THIS HALF

(3) 2x4 SPF #2 THIS HALF

(2) 2x6 SPF #2 THIS HALF

(4) 2x4 SPF #2 THIS HALF

PER APPROVED PACKAGE

COLUMN STRAPPING SCHEDULE

INSTALL TWO STEEL STRAPS AT EACH STUD OF EACH COLUMN.

ALL COLUMN STUDS SHALL BE GLUE/NAILED TOGETHER.

COLUMN STUDS SHALL NOT BE NOTCHED OR BORED.

PVA GLUE WITH 100% COVERAGE SHALL BE USED.

ADD RIDGE BEAM BEARING STIFFENER

STRUCTURAL HEADER ABOVE OPENING

NOTES:

1.

3.

2.

E

G

C

A

(3) 2x4 SPF #2 EACH HALF

(2) 2x4 SPF #2 EACH HALF

(2) 2x6 SPF #2 EACH HALF

(4) 2x4 SPF #2 EACH HALFF

H

D

B

(3) 2x6 SPF #2 THIS HALFJ (3) 2x6 SPF #2 EACH HALFK

A

54321

B

C

D

E

B A

S E

C

IV

IL

E

N G

IN

E

E R

/D E

P U

T Y

C H

IE

F

E N

G

IN

E E

R

IN

G F

L

IG

H T

C

E P

C H

IE

F

C O

N T

R A

C T

S S

E C

T

IO

N

C E

P M

R E

C O

M M

E N

D E

D

R E

C O

M M

E N

D E

D

A P

P R

O V

E D

R E

V D

A T

E E

N G

IN

E

E R

\D E

S

IG

N E

R

D R

A W

N B

Y

S C

A L E

S O

L

IC

IT

A

T

IO

N N

U M

B E

R

C O

N T

R A

C T

N U

M B

E R

D E

S

IG

N T

E A

M C

E P

M

U S

IN

G

A G

E N

C Y

C H

E C

K E

D B

Y

H O

E F

E R

W Y

S O

C K

I A

R C

H

IT

E C

T S

/3

/2

JE DUNN + HWA

CLEARWATER, FL 33756

CONSULTING ENGINEER

1765 CARNEGIE AVENUE

Ph: (727) 505-9941

JAMES E. BRADLEY, P.E.

J E B

0' 4' 8' 16' 32'

1/8" = 1'-0"

0' 2' 4' 8' 16'

1/4" = 1'-0"

0' 1' 2'

3/4" = 1'-0"

4'0' 1'

1 1/2" = 1'-0"

2' 2'1'6"6"3"0' 6"

3" = 1'-0"

1'3"

2500 INDUSTRIAL STREET LEESBURG, FL 34748 (352) 728-2930

TPF TYNDALL - NORTH

PUBLIC HEALTH BLDG

S U

B M

IT

T

A L

C O

R R

E C

T E

D F

IN

A

L

J A

M E

S E

B

R A

D L E

Y

P .E

J .L

.B

J .E

.B

J E

D U

N N

W -1

-R

-6

W -1

-D

-6

A S

I N

D

IC

A T

E D

THIRD PARTY:

& ASSOCIATES

HILBORN, WERNER, CARTER

1627 SOUTH MYRTLE AVE.

CLEARWATER, FLORIDA 33756

F L O

O R

P L A

N

T Y

N D

A L L A

F B

P U

B L

IC

H E

A L T

H B

L D

G

TNA2.0

M

A G

N O

L

IA

C

IR

C L E

T Y

N D

A L L A

F B

F

L

S y m b o l

D es cr ip ti o n T ra ck in g N o

A ct io n

D at e

2 TRPL 2x4 1 1

E 36"x80" EXT DOOR - STEEL - FLUSH -

AND REMOVABLE MULLION

w/STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPING

1 HOUR

FIRE

50 STC

SOUND

GENERIC

WALLS AND INTERIOR PARTITIONS, WOOD-FRAMED

GYPSUM WALLBOARD, WOOD STUDS

ONE LAYER 5/8" TYPE X PLAIN OR PREDECORATED GYPSUM WALLBOARD,

WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE

APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2 X 4 WOOD

STUDS 16" O.C.; JOINTS OF SQUARE EDGE, BEVEL EDGE OR PREDECORATED

WALLBOARD MAY BE LEFT EXPOSED. NOTE: ONE SIDE OF WALL MUST HAVE

RC-1 CHANNELS

JOINTS STAGGERED 16" ON OPPOSITE SIDES. (LOAD-BEARING)

Thickness: 5 1/4"

Approx. Weight: 7 psf

Fire Test: UL R1319-4, -6, 6-17-52;

UL R2717-39, 1-20-66;

UL R3501-52, 3-15-66,

UL Design U305;

ULC Design W301

Sound Test: OR 64-8, 2-4-64

GA FILE NO. WP 3605

UL DESIGN U305

50 STC SOUND

w/BATT INSULATION

AND RC-1 CHANNELS

1 HOUR

FIRE

34 to 46 STC

SOUND

GENERIC

WALLS AND INTERIOR PARTITIONS, WOOD-FRAMED

GYPSUM WALLBOARD, WOOD STUDS

ONE LAYER 5/8" TYPE X PLAIN OR PREDECORATED GYPSUM WALLBOARD,

WATER-RESISTANT GYPSUM BACKING BOARD, OR GYPSUM VENEER BASE

APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2 X 4 WOOD

STUDS 16" O.C.; JOINTS OF SQUARE EDGE, BEVEL EDGE OR PREDECORATED

WALLBOARD MAY BE LEFT EXPOSED.

JOINTS STAGGERED 16" ON OPPOSITE SIDES. (LOAD-BEARING) Thickness: 4 7/8"

Approx. Weight: 7 psf

Fire Test: UL R1319-4, -6, 6-17-52;

UL R2717-39, 1-20-66;

UL R3501-52, 3-15-66,

UL Design U305;

ULC Design W301

Sound Test: OR 64-8, 2-4-64

GA FILE NO. WP 3605

UL DESIGN U305

46 STC SOUND w/BATT

INSULATION

1 TRPL 2x4 1 1

F 48"x80" EXT DOOR - STEEL - FLUSH -w/STEEL FRAME, CLOSER, PANIC HARDWARE, THRESHOLD, WEATHERSTRIPPING

7 SNGL 2x4 - 1

G 36"x80" w/STEEL FRAME, KEYED LEVER LOCKSET

INT. DOOR - SOLD CORE - FLUSH -

SOUND GASKET; STC 47

RATED DOOR

1 SNGL 2x4 - 1

H 48"x80" w/STEEL FRAME, KEYED LEVER LOCKSET

INT. DOOR - SOLD CORE - FLUSH -

WALL MOUNTED MINI-SPLIT

A/C UNIT; (COOLING ONLY)

FREDRICH (350 CFM); BOTTOM

OF UNIT TO BE AT 80" A.F.F.

OUTDOOR CONDENSING UNT; FREDRICH

#MR12CH; OUTSIDE CONDENSING UNIT

(12,300 BTUH COOLING ONLY); ALL

CONDENSATE LINES AND WIRING TO

INDOOR UNITS ARE TO BE SITE

INSTALLED BY SMM; UNIT IS SHIPPED

LOOSE AND SITE INSTALLEDA B C i K MJ L N o P

3/0x6/8

42"G.B.

3/0x6/8 3/0x6/8

/0 x6 /8

3/0x6/8

3/0x6/8 3/0x6/8

3/0x6/8

3/0x6/8 3/0x6/8 3/0x6/8

"V .G

.B

"G .B

3/0x6/8 3/0x6/8 3/0x6/8

3/0x6/8

3/0x6/8 3/0x6/83/0x6/8

/0 x6 /8

/0 x6 /8

/0 x6 /8

3/0x6/8

3/0x6/8 3/0x6/8 3/0x6/83/0x6/8

3/0x6/83/0x6/83/0x6/83/0x6/8

3/0x6/8 3/0x6/8

/0 x6 /8

/0 x6 /8

/0 x6 /8

/0 x6 /8

3/0x6/8

3/0x6/8

/0 x6 /8

/0 x6 /8

3/0x6/8 3/0x6/8

3/0x6/83/0x6/8

3/0x6/8 3/0x6/8

/0 x6 /8

3/0x6/83/0x6/8

3/0x6/83/0x6/83/0x6/84/0x6/8 3/0x6/83/0x6/8

8'-0" 14'-4"

42"G.B.

"G .B

"V .G

.B

10'-10" 5'-0" 8'-0" 9'-6" 9'-6" 9'-6" 37'-0" 8'-0" 8'-0" 9'-9"15'-0"

5'-5"

10'-10"9'-0"9'-0"9'-0"9'-0"8'-8"9'-0"9'-0"9'-0"6'-4"7'-10"7'-10"7'-8"10'-0"10'-4"6'-0"10'-8"9'-0"9'-10"

" 1

5'-0" 5'-4"9'-4"27'-0"

18'-4 1/16" 1

14'-0" 14'-0" 13'-4"

5'-0"12'-4"5'-0"9'-0"9'-0"5'-0"11'-0"3'-0"14'-4" 12'-4"10'-0"

10'-10"

9'-5" 9'-6" 9'-5"

10'-4" 8'-0" 8'-0"

7'-1" 7'-1"

14'-4"14'-4"

5'-0"

MEDICAL

STANDARDS

OFFICE

(MSME)

PROVIDER

OFFICE

PHA

TECHNICIAN

WORKSTATION

PHA

TECHNICIAN

WORKSTATION

NURSE

WORKROOM

SOILED

UTILITY

NCOIC

OFFICE

SHPE OFFICE

INTERVIEW

PHA

INTERVIEW

ROOM

STAFF

TOILET

JANITOR'S

CLOSET

MOP

SINK

30 GAL

W/H

ELECTRICAL

ROOM

COMM

ROOM

PHA/DEPLOYMENT

MED/EXAM

ROOM

LPN

OFFICE

NCOIC

OFFICE

OIC

OFFICE

OPTOMETRIST

OFFICE

VISUAL

FIELD

OPTOMETRIST

OFFICE

SUB-WAITING

TOILET

COPY/FILE

DISTRORECEPTIONWAITING

VISUAL

SCREENING

MULTI-DIAGNOSTIC

ROOM

PUBLIC

HEATH

CENTER

AUDIO

TESTINGTECH

OFFICE /

INT OCC

HEALTH

EXAM

ROOM

EXAM

ROOM

IDMT

EXAM

ROOM

CLEAN

UTILITY

PROVIDER

OFFICE/OICY

PROVIDER

OFFICE

PROVIDER

OFFICE

TECHNOLOGY

OFFICE

STAFF

LOUNGE/TEAM

CONFERENCE

ROOM

TECH

TECH

IDMT

TECH

IDMT

TECH

36" OPENING

FOR REFRIG

ICE MAKER

CONNECTION

H.C. ACCESSIBLE

HI/LOW WATER

FOUNTAIN

(HI/LOW W.F.)

EXAM

ROOM

EXAM

ROOM

EXAM

ROOM

TREATMENT

ROOM

MULTI-DIAGNOSTIC

ROOM

TECH

RECORD

FIXED

SHELVING

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

COPY/FILE

DISTRO

DEPLOYMENT

MED OFFICE

COUNSELING

ROOM

TECHNICIAN

OFFICE/INTERVIEW

COMMUNITY

HEALTH

AUDIO

TESTING

FULL

EYE-LANE

FULL

EYE-LANE

FRAMES

CONTACTS

STORAGE

FOLDED

EYE-LANE

FOLDED

EYE-LANE

FITTING

DISPENSING

AREA

/0 x5 /0

V S

2/0x5/0VS

2/0x5/0VS

2/0x5/0VS

2/0x5/0VS

2/0x5/0VS

2/0x5/0VS

/0 x5 /0

V S

/0 x5 /0

V S

/0 x5 /0

V S

/0 x5 /0

V S

/0 x5 /0

V S

11'-8"

1'-7"

4"4"

10'-10" 11'-4"

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

6"

11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8" 11'-8"

186'-8"

1'-0" 8'-0"

9'-1"

B

B

B

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

B

B

B

B

B

B

B

B B

B

B

B

B B

B

B

B

B B

B

B

B

B

B

B B

B

B H H H A H H H H H H H H H

D

D

B

B

B

D

B

D

B

B B

B

A B B B B

B B B B B B B B B B B B

B

B B B

B G B

1'-7"

B B B B

D

B

B B B B

1'-0" 3'-4" 3'-0" 7" 4'-9"

3'-4"

6'-0"

7'-11"

5'-4" 4'-6"

9" 4'-9"2'-7"6'-0"

GB G G

B G G G

6'-0"

B B

B B

B

B B

B B B B B B B

B

C

B

B

B

B B B H B B B B

B

BBBB

C C

B B

3 3

D

D

B

B

B

B B

B B B

B B8

8 EE

E E

10'-0"

2'-6"2'-6" 2'-6" 2'-6" 2'-6" 2'-6"

B

B

18"

SITE INSTALLED STRUCT

HEADER; TYP. of (2)

F.D.

w/T.P.

F.D.

w/T.P.

2'-11" 11" 3'-9" 2'-7" 3'-3" 4'-0" 4'-5" 4'-11" 6'-9"

8"

1'-0"

1'-0" 5'-3" 6'-4"

3'-7" 5'-0" 6" 7" 6'-0"

3'-0" 5'-0"

4'-2" 6"7'-3" 5'-6" 4'-2" 4'-9"

AD

EXIT BEXIT B

EXIT B

5'-0"

EXIT B EXIT B

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

(4

LA

Y

E R

/4 x

P

LY

W

O O

D

1 1/2"A.V.

1 1/2"B.V.

2"VTR

F.D.

w/T.P.

60"x12"(D) LAMINATED

COUNTER AT 34" A.F.F.

60"x12"(D) LAMINATED

COUNTER AT 34" A.F.F.

60"x12"(D) LAMINATED

COUNTER AT 34" A.F.F.

4'-10"

6"

C-116

175.44 SF

C-117

108.00 SF

C-118b

123.33 SF

C-122

123.33 SF

C-120

84.00 SF

V.R.G.

C-124

123.33 SF

C-125

116.00 SF

D-108

92.00

SF

V.C.T.

A-110

57.85 SF

V.R.G.

A-112

76.00 SF

V.C.T.

D-114

108.00 SF

V.C.T.

D-112

108.00 SF

V.C.T.

D-116

108.00 SF

V.C.T.

D-117

104.00 SF

D-118

108.00 SF

D-119

108.00 SF

E-110

108.00 SF

E-111

108.00 SF

V.C.T.

E-112

187.78 SF

V.C.T.

E-113

60.00 SF

V.C.T.

E-115

57.17 SF

CERAMIC TILE

E-102a

52.36 SF

V.C.T.

E-102

94.79 SF

V.C.T.

E-101

176.94 SF

V.C.T.

E-103

113.75 SF

V.C.T.

E-104

144.44 SF

V.C.T.

D-107

93.33 SF

D-106

93.33 SF

D-103

93.33 SF

C-104

110.84 SF

V.C.T.

C-106

110.84 SF

V.C.T.

110.84 SF

V.C.T.

C-110

93.33 SF

V.C.T.

C-111

105.63 SF

CARPET

C-112

105.63 SF

C-114

105.63 SF

C-115

105.63 SF

C-109

279.56 SF

V.C.T.

C-107

105.15 SF

V.C.T.

C-105

106.08 SF

V.C.T.

C-103

105.15 SF

V.C.T.

C-121

160.06 SF

V.C.T.

C-123

146.81 SF

V.C.T.

A-516

147.00 SF

V.C.T.

D-110

81.00 SF

CARPET

C-102a

195.56 SF

V.C.T.

D-115

137.72 SF

D-113

115.38 SF

D-105

89.33 SF

D-104

89.33 SF

E-108

200.43 SF

V.C.T.

E-109

200.43 SF

V.C.T.

E-114

108.33 SF

V.C.T.

E-107

156.33 SF

V.C.T.

E-105

156.33 SF

V.C.T.

E-116

108.33 SF

V.C.T.

C-113c

140.00 SF

V.C.T.

PANEL "A"

150 AMP

120/208v, 1Ø

PANEL "B"

150 AMP

120/208v, 1Ø

PANEL "C"

150 AMP

120/208v, 1Ø

PANEL "D"

150 AMP

120/208v, 1Ø

PANEL "E"

150 AMP

120/208v, 1Ø

PANEL "F"

150 AMP

120/208v, 1Ø

PANEL "G"

150 AMP

120/208v, 1Ø

PANEL "H"

150 AMP

120/208v, 1Ø

PANEL "i"

150 AMP

120/208v, 1Ø

PANEL "J"

150 AMP

120/208v, 1Ø PANEL "K"

150 AMP

120/208v, 1Ø

PANEL "L"

150 AMP

120/08v, 1Ø

PANEL "M"

150 AMP

120/208v, 1Ø

PANEL "N"

150 AMP

120/208v, 1Ø

PANEL "o"

150 AMP

120/208v, 1Ø

PANEL "P"

150 AMP

120/208v, 1Ø

FLOORS:

NOTE: FLOOR JOISTS IN

UNITS "G & H" FROM 20-0"

TO 40'-0" TO BE 12" O.C.

FLOORS:

NOTE: FLOOR JOISTS IN UNIT

"N" FROM 48'-0" TO 60'-0"

TO BE @ 12" O.C.

(2) 2" CONDUITS

UP THRU FLOOR

I/ D

U N

IT

O/D UNIT

3/4" x 48"x96" PLYWOOD

PAINTED WITH FIRE

RESISTANT PAINT, TYP.

1 1/2"VTR

1 1/2"VTR1 1/2"VTR1 1/2"VTR

1 1/2"VTR1 1/2"VTR 1 1/2"VTR

6/0x6/8

/0 x6 /8

B

MULTI-DIAGNOSTIC

ROOM

E-106

148.89 SF

V.C.T.

B 4/0x6/8

F

EXIT B

W.P.

w/P.C.

7"5'-4"

C-117a c-118a

WAITING

C-101

431.68 SF

V.C.T.

1'-1"

C-108

C-113a

C-113b

C-113d

A-511

RECEPTION RECEPTION

C-102 D-102

COPY/FILE

DISTRO

C-102a

SITE INSTALLED CORRIDOR SITE INSTALLED CORRIDOR SITE INSTALLED CORRIDORSITE INSTALLED CORRIDOR

A A1.0

C

TNA1.0

D A1.0

3/0x6/8

B

4'-11" 3'-9"

10'-10"

/0 x6 /8

B

3/0x6/8

E

EXIT B

6'-0"5'-0"

3/0x6/8

E

EXIT B

A

3/0x6/8

B

/0 x6 /8

B

STORAGE

C-117b

63.00 SF

V.C.T.

B

42"G.B.

"V .G

.B

"G .B

STAFF

TOILETF.D.

w/T.P. A-111

57.85 SF

V.R.G.

3"VTR

PHA

INTERVIEW

ROOM

D-109

94.00

SF

V.C.T.

PHA

INTERVIEW

ROOM

D-111

94.00

SF

V.C.T.

3/0x6/8

B 3/0x6/8

B

3'-9"

A

7" 3'-7" 10"

B A1.0

4'-0"

6"

EXIT B

1 1/2"VTR

1 1/2"VTR

1 1/2"VTR

/2 "V

T R

/2 "V

T R

/2 "V

T R

1 1/2"VTR

SB30B24

W2430W3615 18"

S B

2'-7"4'-0"

24"(D) LAMINATE

COUNTER-TOP @

30" A.F.F.

24"(D) LAMINATE

COUNTER-TOP @

30" A.F.F.

1 1/2"VTR

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

NOTE: DO NOT INSTALL

REMOTE HEADS IN CORRIDOR

INSTALL PLATES, TYP.

SEE TCCA2.0 FOR

ADDITIONAL DETAILS

SEE TCCA2.0 FOR

ADDITIONAL DETAILS

SEE TCCA2.0 FOR

ADDITIONAL DETAILS

B

STC 50

STC 50 STC 50 STC 50

STC 50STC 50STC 50

A

TNA2.1

B

TNA2.1

H

TNA2.1

C

TNA2.1

18'-4"

D

TNA2.1

G

TNA2.1

E

TNA2.1

F

TNA2.1

E

TNA2.1

F

TNP1.0

STC 50

CORRIDOR

D-101

WAITING

TECH

WORKSTATION

E-116a

CARPET

CARPET

CARPET

CARPET

CARPET

CARPET

CARPET CARPET CARPET

CARPET

CARPET

CARPET

CARPET

CARPET

CARPET

CARPET

CARPET CARPET CARPET CARPET

18"

MIN.

18"

MIN.

18"

MIN.

18"

MIN.

18"

MIN.

18"

MIN.

18"

MIN.

18"

MIN.

18"

MIN.

D E F G H

BCB36

B

3"VTR

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

3.0 TON WALL HUNG HVAC UNIT

(MD#:W36A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 1000 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT (MD#:W30A2-A10XP)

INSTALLED PER MFG'R SPEC'S w/7.5 kW HEAT STRIP;

1000 CFM @ .4 IWC ESP w/25% FRESH AIR INTAKE AND

DEHUMIDIFIER ; 208v 1Ø; w/2 INCH MERV-8 PLEATED

FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE AND

DEHUMIDIFIER ; 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE AND

DEHUMIDIFIER ; 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/25% FRESH AIR INTAKE; 208v 1Ø;

w/2 INCH MERV-8 PLEATED FILTER

2.5 TON WALL HUNG HVAC UNIT

(MD#:W30A2-A10XP) INSTALLED

PER MFG'R SPEC'S w/7.5 kW HEAT

STRIP; 850 CFM @ .4 IWC ESP

w/DEHUMIDIFIER AND C.R.V. (50%

FRESH AIR INTAKE); 208v 1Ø; w/2

INCH MERV-8 PLEATED FILTER

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

LINE PLENUM WALL WITH

MIN. 1/2" GYPSUM, TYP.

FASTENED w/(16) .131"x 3" GUN NAILS.

STRAP w/MIN. 36" ABOVE FLOOR DECK;

INSTALL (1) 20 GA. x 1 1/2" x 80" STEEL

FLOOR TO GROUND ANCHOR BELOW

REMAINDER OF STRAP SHALL BE FED THROUGH

T Y

P

NOTE: ADJUST #LTS20 STRAPS UPWARD

SO THAT BOTTOM STRAP IS FLUSH AT THE

BOTTOM w/THE BOTTOM EDGE OF THE HEADER

STRUCT HEADER DETAIL

SITE INSTALLED

DETAIL "A"

SCALE: N.T.S.

HEADER

(PLAN VIEW)

SITE INSTALLED

EQUAL; FASTENED w/(8) 10d NAILS

OF STRAP THROUGH TO BELOW

NOTE: CUT SLIT IN FLOOR

DECKING TO ALLOW FEEDING

LOCATED UNDER SITE

INSTALLED HEADER

TRIPLE FLOOR JOISTS

NOTE: TYPICAL AT OTHER SIDE

OF MATELINE ALSO

PER END

MATELINE

STRUCT HEADER AND RIDGEBEAM

w/(12) 10d NAILS PER STRAP END

(ONE STRAP EACH SIDE OF MATELINE)

HEADER TO JACK STUDS w/(1) SIMPSON

#LSTA24 STRAP OR AN APPROVED

SECURE EACH SIDE OF SITE INSTALLED

w/(12) 10d NAILS PER STRAP END

STRUCT HEADER AND RIDGEBEAM

FASTENED TO SITE INSTALLED

SIMPSON #LTS20 STRAP

RIDGE

BEAM

SIMPSON #LTS20 STRAP

FASTENED TO SITE INSTALLED

MATELINE

1. FOR EACH 1.5" THICKNESS OF EACH HEADER A 2x4 SPF #2 JACK STUD

SPAN. EACH SIDE OF HEADER SPAN SHALL ALSO HAVE 2-2x4 SPF

SHALL BE INSTALLED FOR HEADER SUPPORT ON EACH SIDE OF THE

5. - # OF LAYERS OF 3/4" x 11-1/4" RATED SHEATHING, PLYWOOD

A 30° ANGLE FROM JACK STUD AND STARTING APPROXIMATELY

JACK STUD INTO FLOOR JOIST BELOW. INSTALL LAG SCREW

B. INSTALL 1-3/8" x 6" LAG SCREW FROM EACH SIDE OF EACH

2" ABOVE THE END OF THE STUD. PRE-DRILL ALL HOLES WITH

4. HEADERS CONSISTING OF PLYWOOD SHALL BE CONSTRUCTED IN ACCORDANCE

WITH THE "RIDGE BEAM CONSTRUCTION" NOTES SPECIFIED HERE IN OR IN

THE SYSTEM PACKAGE EXCEPT THAT THERE SHALL BE NO BUTT JOINT IN

STRAP TO RIDGE BEAM ON THE RAFTER SIDE OF THE RIDGE BEAM.

A. INSTALL (2) SIMPSON HTS 16 FROM RIDGE BEAM TO HEADER. ATTACH

#2 FULL LENGTH STUDS WITH EACH STUD FASTENED TO JACK

2. A FLOOR JOIST SHALL BE INSTALLED DIRECTLY UNDER EACH

WITH 3-16d COMMON NAILS. NOTE: STUDS MAY BE SITE INSTALLED.

STUDS WITH 16d COMMON NAILS 12" O.C., AND FASTENED TO HEADER

3. UPLIFT WIND ANCHORAGE

ANY OF THE PLYWOOD LAYERS.

STRUCT. 1, EXP. 1 48/24, 5 PLY/ 5 LAYER.

SEE DETAIL ON SHEET 6 of 6.

REQUIRED JACK STUD, EACH SIDE OF HEADER.

SITE INSTALLED HEADER NOTES:

BY JACK STUDS UNDERNEATH

NOTE: HEADER SHALL BE SUPPORTED

FULL STUD SUPPORT COLUMN; ALL

JACK AND FULL STUDS SHOULD BE

SITE INSTALLED HEADER JACK AND

OF MATELINE ALSO

TYPICAL AT OTHER SIDE

GLUED/NAILED TOGETHER

1/4" DIAMETER BIT.

SEE DETAIL "A"

tracbr Text Box Amendment 1 tracbr Rectangle tracbr Text Box 3/15/2017 tim.kitchens Snapshot tim.kitchens Rectangle tim.kitchens Rectangle

File details come from the government source that posted it.