Attachment_4_-_AFRRI_Design_Volume_1.pdf

PDF 46 MB Posted

Attached to
Defense Health Agency Armed Forces Radiobiology Research Institute Initial Outfitting
Solicitation number
W9127S18R6031
Issued by

About this file

AFRRI Design Volume 1

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

E S T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I N

T E

R I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

5 6 7 8 9

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

A R C H I T E C T U R E

E N G I N E E R I N G

I N T E R I O R S

P L A N N I N G

7/27/2017 2:11:17 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI001A

T en th

S tr ee t N

.E

S u it e

A tl an ta

G A

U

SA

T el

-8

-8

F ax

-8

-8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs ity S q

H u n ts v ill e A

L

C O

V E

R S

H E

E T

V

O L U

M E o f

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

V .P

A T

E L

L .W

R

IG

H T

L .W

R

IG

H T

J U

L Y

L .W

R

IG

H T

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

8901 WISCONSIN AVE, BETHESDA, MD 20889

ARCHITECTURAL AND ENGINEERING SERVICES

ARMED FORCES RADIOBIOLOGY RESEARCH

INSTITUTE (AFRRI) BLDG. 43/47 DESIGN

XXXXXX-XX-X-XXXX

W912DY-13-D-0121

JULY 2017

HUNTSVILLE CENTER

VOLUME 1 of 3

D

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

E S T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I N

T E

R I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

5 6 7 8 9

STAMP

7/27/2017 2:12:51 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI002

T en th

S tr ee t N

.E

S u it e

A tl an ta

G A

U

SA

T el

-8

-8

F ax

-8

-8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs ity S q

H u n ts v ill e A

L

S H

E E

T I N

D E

X

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

V .P

A T

E L

L .W

R

IG

H T

L .W

R

IG

H T

J U

L Y

L .W

R

IG

H T

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

ED101 ELECTRICAL DEMOLITION PLAN - BASEMENT AND FIRST FLOOR

ED102 ELECTRICAL DEMOLITION PLAN - SECOND FLOOR

ED103 ELECTRICAL DEMOLITION PLAN - THIRD FLOOR

ED104 ELECTRICAL DEMOLITION PLAN - PENTHOUSES AND ROOF

EP101 BLDG 43 - LIGHTNING PROTECTION PLAN

EP102 BLDG 47 - LIGHTNING PROTECTION PLAN

EP111 BLDG 43 - POWER PLAN - FIRST FLOOR

EP112 BLDG 43 - POWER PLAN - SECOND FLOOR

EP113 BLDG 43 - POWER PLAN - THIRD FLOOR

EP114 BLDG 43 - POWER PLAN - PENTHOUSE

EP120 BLDG 47 - POWER PLAN - BASEMENT

EP121 BLDG 47 - POWER PLAN - FIRST FLOOR

EP122 BLDG 47 - POWER PLAN - SECOND FLOOR

EP123 BLDG 47 - POWER PLAN - THIRD FLOOR

EP124 BLDG 47 - POWER PLAN - PENTHOUSE

EP125 BLDG 43/47 - POWER PLAN - ROOF

EP201 OVERALL MECHANICAL POWER PLAN - FIRST FLOOR

EP202 OVERALL MECHANICAL POWER PLAN - SECOND FLOOR

EP203 OVERALL MECHANICAL POWER PLAN - THIRD FLOOR

EP401 ELECTRICAL LARGE SCALE PLANS

EP402 ELECTRICAL LARGE SCALE PLANS

EP403 ELECTRICAL LARGE SCALE PLANS

EP404 ELECTRICAL LARGE SCALE PLANS - TYPICAL ANIMAL ROOM RACEWAYS

EP405 ELECTRICAL LARGE SCALE PLANS

EP501 ELECTRICAL DETAILS

EP502 ELECTRICAL DETAILS

EP503 ELECTRICAL DETAILS

EP504 ELECTRICAL DETAILS - MAIN ELECTRICAL FEEDERS ROUTING

EP505 ELECTRICAL DETAILS - PRIMARY FEEDERS ROUTING

EP506 ELECTRICAL DETAILS

EP601 ELECTRICAL ONE LINE DIAGRAM

EP602 ELECTRICAL RISER DIAGRAMS

EP603 ELECTRICAL RISER DIAGRAMS

EP604 ELECTRICAL SCHEDULES

EP605 ELECTRICAL SCHEDULES

EP606 ELECTRICAL SCHEDULES

EP607 ELECTRICAL SCHEDULES

EP608 ELECTRICAL SCHEDULES

EP609 ELECTRICAL SCHEDULES

EP610 ELECTRICAL SCHEDULES

EP611 ELECTRICAL SCHEDULES

EP612 ELECTRICAL SCHEDULES

EP613 ELECTRICAL SCHEDULES

EP614 ELECTRICAL SCHEDULES

EP615 ELECTRICAL SCHEDULES

EP616 ELECTRICAL SCHEDULES

EL111 BLDG 43 - LIGHTING PLAN - FIRST FLOOR

EL112 BLDG 43 - LIGHTING PLAN - SECOND FLOOR

EL113 BLDG 43 - LIGHTING PLAN - THIRD FLOOR

EL114 BLDG 43 - LIGHTING PLAN - PENTHOUSE

EL120 BLDG 47 - LIGHTING PLAN - BASEMENT

EL121 BLDG 47 - LIGHTING PLAN - FIRST FLOOR

EL122 BLDG 47 - LIGHTING PLAN - SECOND FLOOR

EL123 BLDG 47 - LIGHTING PLAN - THIRD FLOOR

EL124 BLDG 47 - LIGHTING PLAN - PENTHOUSE

EL501 LIGHTING DETAILS

EL601 LIGHTING FIXTURE SCHEDULE AND CONTROLS

ET111 BLDG 43 - TELECOMMUNICATIONS PLAN - FIRST FLOOR

ET112 BLDG 43 - TELECOMMUNICATIONS PLAN - SECOND FLOOR

ET113 BLDG 43 - TELECOMMUNICATIONS PLAN - THIRD FLOOR

ET114 BLDG 43 - TELECOMMUNICATIONS PLAN - PENTHOUSE

ET120 BLDG 47 - TELECOMMUNICATIONS PLAN - BASEMENT

ET121 BLDG 47 - TELECOMMUNICATIONS PLAN - FIRST FLOOR

ET122 BLDG 47 - TELECOMMUNICATIONS PLAN - SECOND FLOOR

ET123 BLDG 47 - TELECOMMUNICATIONS PLAN - THIRD FLOOR

ET124 BLDG 47 - TELECOMMUNICATIONS PLAN - PENTHOUSE

ET501 TELECOMMUNICATIONS DETAILS

ET511 LOW VOLTAGE SYSTEMS RACEWAY ROUTING - FIRST FLOOR

ET512 LOW VOLTAGE SYSTEMS RACEWAY ROUTING - SECOND FLOOR

ET513 LOW VOLTAGE SYSTEMS RACEWAY ROUTING - THIRD FLOOR

ET601 TELECOMMUNICATIONS DIAGRAMS AND DETAILS

ET602 TELECOMMUNICATIONS DIAGRAMS AND DETAILS

EY111 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - FIRST FLOOR

EY112 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - SECOND FLOOR

EY113 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - THIRD FLOOR

EY114 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - PENTHOUSE

EY120 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - BASEMENT

EY121 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - FIRST FLOOR

EY122 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - SECOND FLOOR

EY123 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - THIRD FLOOR

EY124 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - PENTHOUSE

EY601 ELECTRONIC SECURITY SYSTEM DIAGRAMS AND DETAILS

EY602 ELECTRONIC SECURITY SYSTEM DIAGRAMS AND DETAILS

EY603 ELECTRONIC SECURITY SYSTEM DIAGRAMS AND DETAILS

Grand total: 491

PP221 BLDG 47 - MEDICAL GAS PLAN - BASEMENT

PP222 BLDG 47 - MEDICAL GAS PLAN - FIRST FLOOR

PP223 BLDG 47 - MEDICAL GAS PLAN - SECOND FLOOR

PP224 BLDG 47 - MEDICAL GAS PLAN - THIRD FLOOR

PP225 BLDG 47 - MEDICAL GAS PLAN - PENTHOUSE

PP311 BLDG 43 - PLUMBING PLAN - FIRST FLOOR - ANIMAL WATERING PIPING

PP322 BLDG 47 - PLUMBING PLAN - FIRST FLOOR - ANIMAL WATERING PIPING

PP323 BLDG 47 - PLUMBING PLAN - SECOND FLOOR - ANIMAL WATERING PIPING

PP324 BLDG 47 - PLUMBING PLAN - THIRD FLOOR - ANIMAL WATERING PIPING

PP501 PLUMBING DETAILS

PP502 PLUMBING DETAILS

PP503 PLUMBING DETAILS

PP601 BLDG 43 - DOMESTIC WATER RISER DIAGRAMS

PP602 BLDG 43 INDUSTRIAL WATER RISER DIAGRAM

PP603 BLDG 47 - INDUSTRIAL WATER RISER DIAGRAMS

PP604 BLDG 47 - DOMESTIC WATER RISER DIAGRAMS

PP605 BLDG 43 - SANITARY RISER DIAGRAMS

PP606 BLDG 47 - SANITARY RISER DIAGRAMS

PP607 BLDG 43 - MEDICAL GAS RISER DIAGRAM

PP608 BLDG 47 - MEDICAL GAS RISER DIAGRAM

PP609 ANIMAL WATERING RISER DIAGRAM

PP610 NATURAL GAS RISER DIAGRAM

PP611 BLDG 47 - STORM RISER DIAGRAM

PP701 PLUMBING SCHEDULES

PP702 PLUMBING SCHEDULES

MECHANICAL

M-001 MECHANICAL SYMBOLS, GENERAL NOTES

MD111 BLDG 43 - HVAC DEMO - FIRST FLOOR

MD112 BLDG 43 - HVAC PIPING - SECOND FLOOR

MD113 BLDG 43 - HVAC DEMO - THIRD FLOOR

MD114 BLDG 43 HVAC DEMO - PENTHOUSE

MD115 BLDG 43 - HVAC DEMO - PENTHOUSE ROOF

MD121 BLDG 47 - HVAC AND PIPING DEMOLITION PLAN - FIRST FLOOR

MD122 BLDG 47 - HVAC AND PIPING DEMOLITION PLAN - SECOND FLOOR

MD123 BLDG 47 - HVAC DEMO - THIRD FLOOR

MD124 BLDG 47 - HVAC DEMO - PENTHOUSE

MD125 BLDG 47 - HVAC DEMO - PENTHOUSE ROOF

MH111 BLDG 43 - HVAC PLAN - FIRST FLOOR

MH112 BLDG 43 - HVAC PLAN - SECOND FLOOR

MH113 BLDG 43 - HVAC PLAN - THIRD FLOOR

MH114 BLDG 43 - HVAC PLAN - PENTHOUSE

MH115 BLDG 43 - HVAC PLAN - PENTHOUSE ROOF

MH120 BLDG 47 - HVAC PLAN - BASEMENT

MH121 BLDG 47 - HVAC PLAN - FIRST FLOOR

MH122 BLDG 47 - HVAC PLAN - SECOND FLOOR

MH123 BLDG 47 - HVAC PLAN - THIRD FLOOR

MH124 BLDG 47 - HVAC PLAN - PENTHOUSE

MH125 BLDG 47 - HVAC PLAN - PENTHOUSE ROOF

MH130 BLDG 47 - ROOM PRESSURIZATION PLAN - FIRST FLOOR

MH131 BLDG 47 - ROOM PRESSURIZATION PLAN - SECOND FLOOR

MH132 BLDG 47 - ROOM PRESSURIZATION PLAN - THIRD FLOOR

MH133 BLDG 43 - ROOM PRESSURIZATION PLAN - FIRST FLOOR

MH134 BLDG 43 - ROOM PRESSURIZATION PLAN - SECOND FLOOR

MH135 BLDG 43 -ROOM PRESSURIZATION PLAN - THIRD FLOOR

MH301 BLDG 47 MECHANICAL SECTIONS

MH302 BLDG 47 MECHANICAL SECTIONS

MH303 BLDG 43 MECHANICAL SECTIONS

MH304 BLDG 47 MECHANICAL AIR HANDLING UNIT ELEVATIONS

MH305 BLDG 47 MECHANICAL AIR HANDLING UNIT ELEVATIONS

MH401 BLDG 47 - HVAC LARGE SCALE PLANS AND SECTIONS

MH402 BLDG 43 - HVAC LARGE SCALE PLAN - SECOND FLOOR MECHANCIAL ROOM

MH403 BLDG 43 - HVAC LARGE SCALE PLAN - PENTHOUSE MECHANICAL ROOM

MH501 MECHANICAL DETAILS

MH502 MECHANICAL DETAILS

MH503 MECHANICAL DETAILS

MH601 BLDG 43 MECHANICAL SCHEDULES

MH602 BLDG 43 MECHANICAL SCHEDULES

MH603 BLDG 47 - MECHANICAL SCHEDULES

MH604 BLDG 47 - MECHANICAL SCHEDULES

MH605 BLDG 47 - MECHANICAL SCHEDULES

MH606 BLDG 47 - MECHANICAL SCHEDULES

MH607 BLDG 47 - MECHANICAL SCHEDULES

MH701 HEATING WATER HVAC FLOW DIAGRAM

MH702 STEAM HVAC FLOW DIAGRAM B-47

MH703 HEATING HOT WATER AND CHILLED WATER FLOW DIAGRAM B-43

MH704 STEAM HVAC FLOW DIAGRAM B-43

MH705 HEATING HOT WATER AND CHILLED WATER FLOW DIAGRAM B-47

MH801 HVAC CONTROLS

MH802 HVAC CONTROLS

MH803 HVAC CONTROLS

MH804 HVAC CONTROLS

MH805 HVAC CONTROLS

MH806 HVAC CONTROLS

MH807 HVAC CONTROLS

MH808 HVAC CONTROLS

MH809 HVAC CONTROLS

MH810 HVAC CONTROLS

MH811 HVAC CONTROLS

MH812 HVAC CONTROLS

MP111 HVAC PIPING PLAN - BLDG 43 - FIRST FLOOR

MP112 HVAC PIPING PLAN - BLDG 43 - SECOND FLOOR

MP113 HVAC PIPING PLAN - BLDG 43 - THIRD FLOOR

MP114 HVAC PIPING PLAN - BLDG 43 - PENTHOUSE

MP121 HVAC PIPING PLAN - BLDG - 47 - FIRST FLOOR

MP122 HVAC PIPING PLAN - BLDG 47 - SECOND FLOOR

MP123 HVAC PIPING PLAN - BLDG 47 - THIRD FLOOR

MP124 HVAC PIPING PLAN - BLDG 47 - PENTHOUSE

ELECTRICAL

E-001 ELECTRICAL SYMBOL LEGEND

E-002 ELECTRICAL GENERAL NOTES AND ABBREVIATIONS

E-003 ELECTRICAL UTILITIES SEQUENCING

E-004 ELECTRICAL RISER DIAGRAMS & SCHEDULES - BLDG 48

ES101 ELECTRICAL SITE PLAN - UTILTIES

ES102 ELECTRICAL SITE LIGHTING PLAN

PLUMBING

P-001 PLUMBING ABBREVIATIONS, SYMBOLS, GENERAL NOTES

PD111 BLDG 43 - PLUMBING DEMO - FIRST FLOOR

PD112 BLDG 43 - PLUMBING DEMO - SECOND FLOOR

PD113 BLDG 43 - PLUMBING DEMO - THIRD FLOOR

PD114 BLDG 43 - PLUMBING DEMO - PENTHOUSE

PD120 BLDG 47 - PLUMBING DEMO - BASEMENT FLOOR

PD121 BLDG 47 - PLUMBING DEMO - FIRST FLOOR

PD122 BLDG 47 - PLUMBING DEMO - SECOND FLOOR

PD123 BLDG 47 - PLUMBING DEMO - THIRD FLOOR

PD124 BLDG 47 - PLUMBING DEMO - PENTHOUSE

PP111 BLDG 43 - PLUMBING PLAN - FIRST FLOOR - WATER PIPING

PP112 BLDG 43 - PLUMBING PLAN - SECOND FLOOR - WATER PIPING

PP113 BLDG 43 - PLUMBING PLAN - THIRD FLOOR - WATER PIPING

PP114 BLDG 43 - PLUMBING PLAN - PENTHOUSE - WATER PIPING

PP115 BLDG 43 - PLUMBING PLAN - FOUNDATION - SANITARY/STORM SEWER

PP116 BLDG 43 - PLUMBING PLAN - FIRST FLOOR - SANITARY/STORM SEWER

PP117 BLDG 43 - PLUMBING PLAN - SECOND FLOOR - SANITARY/STORM SEWER

PP118 BLDG 43 - PLUMBING PLAN - THIRD FLOOR - SANITARY/STORM SEWER

PP119 BLDG 43 - PLUMBING PLAN - PENTHOUSE - SANITARY/STORM SEWER

PP120 BLDG 47 - PLUMBING PLAN - FOUNDATION - SANITARY/STORM SEWER

PP121 BLDG 47 - PLUMBING PLAN - BASEMENT FLOOR - WATER PIPING

PP122 BLDG 47 - PLUMBING PLAN - FIRST FLOOR - WATER PIPING

PP123 BLDG 47 - PLUMBING PLAN - SECOND FLOOR - WATER PIPING

PP124 BLDG 47 - PLUMBING PLAN - THIRD FLOOR - WATER PIPING

PP125 BLDG 47 - PLUMBING PLAN - PENTHOUSE - WATER PIPING

PP126 BLDG 47 - PLUMBING PLAN - BASEMENT - SANITARY/STORM SEWER

PP127 BLDG 47 - PLUMBING PLAN - FIRST FLOOR - SANITARY/STORM SEWER

PP128 BLDG 47 - PLUMBING PLAN - SECOND FLOOR - SANITARY/STORM SEWER

PP129 BLDG 47 - PLUMBING PLAN - THIRD FLOOR - SANITARY/STORM SEWER

PP130 BLDG 47 - PLUMBING PLAN - SANITARY/STORM SEWER - PENTHOUSE

PP131 BLDG 47 - PLUMBING PLAN - SANITARY/STORM SEWER - PENTHOUSE ROOF

PP213 BLDG 43 - MEDICAL GAS PLAN - THIRD FLOOR

PP214 BLDG 43 - MEDICAL GAS PLAN - PENTHOUSE

AE521 ROOF DETAILS

AE522 ROOF DETAILS

AE531 DOOR DETAILS

AE532 DOOR DETAILS

AE533 DOOR DETAILS

AE534 DOOR DETAILS

AE541 EXPANSION JOINT DETAILS

AE542 EXPANSION JOINT DETAILS

AE543 EXPANSION JOINT DETAILS

AE551 PARTITION TYPES

AE560 CASEWORK DETAILS

AE561 CASEWORK DETAILS

AE562 MILLWORK DETAILS

AE571 MISCELLANEOUS DETAILS

AE601 ROOM SCHEDULE

AE602 ROOM FINISH SCHEDULE

AE603 DOOR SCHEDULE

AE604 WINDOW AND LOUVER TYPES AND DETAILS

INTERIOR

IF111 BLDG 43 - INTERIOR FINISHES - FIRST FLOOR

IF112 BLDG 43 - INTERIOR FINISHES - SECOND FLOOR

IF113 BLDG 43 - INTERIOR FINISHES - THIRD FLOOR

IF120 BLDG 47 - INTERIOR FINISHES - BASEMENT

IF121 BLDG 47 - INTERIOR FINISHES - FIRST FLOOR

IF122 BLDG 47 - INTERIOR FINISHES - SECOND FLOOR

IF123 BLDG 47 - INTERIOR FINISHES - THIRD FLOOR

IN111 BLDG 43 - FURNITURE PLAN - FIRST FLOOR

IN112 BLDG 43 - FURNITURE PLAN - SECOND FLOOR

IN121 BLDG 47 - FURNITURE PLAN - FIRST FLOOR

IN122 BLDG 47 - FURNITURE PLAN - SECOND FLOOR

IN123 BLDG 47 - FURNITURE PLAN - THIRD FLOOR

IN125 FURNITURE SCHEDULE

IN126 SIGNAGE SCHEDULE

IN127 SIGNAGE DETAILS

IN427 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

IN428 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

IN429 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

IN430 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

FIRE PROTECTION

FA101 FIRE ALARM ZONING PLAN

FA102 FIRE ALARM DEMOLITION PLAN

FA103 SMOKE CONTROL ZONING PLAN

FA110 BLDG 43 - FIRE ALARM PLAN - BASEMENT

FA111 BLDG 43 - FIRE ALARM PLAN - FIRST FLOOR

FA112 BLDG 43 - FIRE ALARM PLAN - SECOND FLOOR

FA113 BLDG 43 - FIRE ALARM PLAN - THIRD FLOOR

FA114 BLDG 43 - FIRE ALARM PLAN - PENTHOUSE

FA120 BLDG 47 - FIRE ALARM PLAN - BASEMENT

FA121 BLDG 47 - FIRE ALARM PLAN - FIRST FLOOR

FA122 BLDG 47 - FIRE ALARM PLAN - SECOND FLOOR

FA123 BLDG 47 - FIRE ALARM PLAN - THIRD FLOOR

FA124 BLDG 47 - FIRE ALARM PLAN - PENTHOUSE

FA601 FIRE ALARM RISER DIAGRAM

FX101 FIRE SUPPRESSION ZONING PLAN

FX102 FIRE SUPPRESSION DEMOLITION PLAN

FX110 BLDG 43 - FIRE SUPPRESSION PLAN - BASEMENT

FX111 BLDG 43 - FIRE SUPPRESSION PLAN - FIRST FLOOR

FX112 BLDG 43 - FIRE SUPPRESSION PLAN - SECOND FLOOR

FX113 BLDG 43 - FIRE SUPPRESSION PLAN - THIRD FLOOR

FX114 BLDG 43 - FIRE SUPPRESSION PLAN - PENTHOUSE

FX120 BLDG 47 - FIRE SUPPRESSION PLAN - BASEMENT

FX121 BLDG 47 - FIRE SUPPRESSION PLAN - FIRST FLOOR

FX122 BLDG 47 - FIRE SUPPRESSION PLAN - SECOND FLOOR

FX123 BLDG 47 - FIRE SUPPRESSION PLAN - THIRD FLOOR

FX124 BLDG 47 - FIRE SUPPRESSION PLAN - PENTHOUSE

FX601 FIRE SUPPRESSION DETAILS

ARCHITECTURAL

AS101 AT/FP SITE PLAN

AD111 BLDG 43 - DEMOLITION PLAN - FIRST FLOOR

AD112 BLDG 43 - DEMOLITION PLAN - SECOND FLOOR

AD113 BLDG 43 - DEMOLITION PLAN - THIRD FLOOR

AD114 BLDG 43 - DEMOLITION PLAN - PENTHOUSE

AD115 BLDG 43 - DEMOLITION PLAN - PENTHOUSE ROOF

AD120 BLDG 47 - DEMOLITION PLAN - BASEMENT

AD121 BLDG 47 - DEMOLITION PLAN - FIRST FLOOR

AD122 BLDG 47 - DEMOLITION PLAN - SECOND FLOOR

AD123 BLDG 47 - DEMOLITION PLAN - THIRD FLOOR

AD124 BLDG 47 - DEMOLITION PLAN - PENTHOUSE

AD125 BLDG 47 - DEMOLITION PLAN - PENTHOUSE ROOF

AE100 COMPOSITE FLOOR PLAN - BASEMENT

AE101 COMPOSITE FLOOR PLAN - FIRST FLOOR

AE102 COMPOSITE FLOOR PLAN - SECOND FLOOR

AE103 COMPOSITE FLOOR PLAN - THIRD FLOOR

AE104 COMPOSITE FLOOR PLAN - PENTHOUSE

AE105 COMPOSITE FLOOR PLAN - ROOF

AE111 BLDG 43 - FLOOR PLAN - FIRST FLOOR

AE112 BLDG 43 - FLOOR PLAN - SECOND FLOOR

AE113 BLDG 43 - FLOOR PLAN - THIRD FLOOR

AE114 BLDG 43 - FLOOR PLAN - PENTHOUSE

AE115 BLDG 43 - FLOOR PLAN - ROOF

AE120 BLDG 47 - FLOOR PLAN - BASEMENT

AE121 BLDG 47 - FLOOR PLAN - FIRST FLOOR

AE122 BLDG 47 - FLOOR PLAN - SECOND FLOOR

AE123 BLDG 47 - FLOOR PLAN - THIRD FLOOR

AE124 BLDG 47 - FLOOR PLAN - PENTHOUSE

AE125 BLDG 47 - FLOOR PLAN - ROOF

AE131 BLDG 43 - REFLECTED CEILING PLAN - FIRST FLOOR

AE132 BLDG 43 - REFLECTED CEILING PLAN - SECOND FLOOR

AE133 BLDG 43 - REFLECTED CEILING PLAN - THIRD FLOOR

AE134 BLDG 43 - REFLECTED CEILING PLAN - PENTHOUSE

AE140 BLDG 47 - REFLECTED CEILING PLAN - BASEMENT

AE141 BLDG 47 - REFLECTED CEILING PLAN - FIRST FLOOR

AE142 BLDG 47 - REFLECTED CEILING PLAN - SECOND FLOOR

AE143 BLDG 47 - REFLECTED CEILING PLAN - THIRD FLOOR

AE144 BLDG 47 - REFLECTED CEILING PLAN - PENTHOUSE

AE151 COMPOSITE AIR BARRIER FLOOR PLAN - FIRST FLOOR

AE201 BLDG 43 - EXTERIOR ELEVATIONS

AE202 BLDG 43 - EXTERIOR ELEVATIONS

AE203 BLDG 43 - EXTERIOR ELEVATIONS

AE204 BLDG 47 - EXTERIOR ELEVATIONS

AE205 BLDG 47 - EXTERIOR ELEVATIONS

AE206 BLDG 47 - EXTERIOR ELEVATIONS

AE207 BLDG 47 - EXTERIOR ELEVATIONS

AE208 BLDG 47/43 - EXTERIOR ELEVATIONS

AE301 BLDG 43 - BUILDING SECTIONS

AE302 BLDG 43 - BUILDING SECTIONS

AE303 BLDG 47 - BUILDING SECTIONS

AE304 BLDG 47 - BUILDING SECTIONS

AE305 BLDG 47 - BUILDING SECTIONS

AE306 BLDG 47 - BUILDING SECTIONS

AE307 BLDG 47 - BUILDING SECTIONS

AE308 BLDG 47 - BUILDING SECTIONS

AE311 BLDG 43 - WALL SECTIONS

AE312 BLDG 43 - WALL SECTIONS

AE313 BLDG 43 - WALL SECTIONS

AE314 BLDG 43 - WALL SECTIONS

AE315 BLDG 43/47 - WALL SECTIONS

AE316 BLDG 47 - WALL SECTIONS

AE317 BLDG 47 - WALL SECTIONS

AE318 BLDG 47 - WALL SECTIONS

AE319 BLDG 47 - WALL SECTIONS

AE320 BLDG 47 - WALL SECTIONS

AE401 STANDARD MOUNTING HEIGHT

AE402 BLDG 43 - ENLARGED RESTROOM PLANS & INTERIOR ELEVATIONS

AE403 BLDG 47 - ENLARGED RESTROOM PLANS & INTERIOR ELEVATIONS

AE404 BLDG 43 - ENLARGED STAIR PLANS AND SECTIONS

AE406 BLDG 47 - ENLARGED STAIR AND ELEVATOR PLANS

AE407 BLDG 47 - ENLARGED STAIR AND ELEVATOR PLANS AND SECTIONS

AE408 BLDG 47 - ENLARGED STAIR PLANS AND SECTIONS

AE409 BLDG 47 - ENLARGED ELEVATOR/RAMP PLANS AND SECTION

AE410 BLDG 43/47 - STAIR DETAILS

AE421 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE422 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE423 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE424 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE425 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE426 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE431 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE432 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE433 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE434 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE435 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE436 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE437 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE438 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE439 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE440 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS

AE441 BLDG 43 - ENLARGED REFLECTED CEILING PLANS

AE442 BLDG 47 - ENLARGED REFLECTED CEILING PLANS

AE501 PLAN DETAILS

AE502 PLAN DETAILS

AE503 PLAN DETAILS

AE504 PLAN DETAILS

AE505 PLAN DETAILS

AE506 PLAN DETAILS

AE507 PLAN DETAILS

AE508 PLAN DETAILS

AE509 PLAN DETAILS

AE511 SECTION DETAILS

AE512 SECTION DETAILS

AE513 SECTION DETAILS

AE514 SECTION DETAILS

AE515 SECTION DETAILS

AE516 SECTION DETAILS

GENERAL

GI001A COVER SHEET - VOLUME 1 of 3

GI001B COVER SHEET - VOLUME 2 of 3

GI001C COVER SHEET - VOLUME 3 of 3

GI002 SHEET INDEX

GI003 LEGEND AND ABBREVIATIONS

GI004 LOCATION MAP

GI005 FIRE PROTECTION LIFE SAFETY SITE PLAN

GI006 BUILDING CODE ANALAYSIS AND GENERAL NOTES

GI007 PHASING PLANS

GI100 COMPOSITE LIFE SAFETY PLAN - BASEMENT

GI101 COMPOSITE LIFE SAFETY PLAN - FIRST FLOOR

GI102 COMPOSITE LIFE SAFETY PLAN - SECOND FLOOR

GI103 COMPOSITE LIFE SAFETY PLAN - THIRD FLOOR

GI104 COMPOSITE LIFE SAFETY PLAN - PENTHOUSE

GI110 BLDG 43 - LIFE SAFETY PLAN - BASEMENT

GI111 BLDG 43 - LIFE SAFETY PLAN - FIRST FLOOR

GI112 BLDG 43 - LIFE SAFETY PLAN - SECOND FLOOR

GI113 BLDG 43 - LIFE SAFETY PLAN - THIRD FLOOR

GI114 BLDG 43 - LIFE SAFETY PLAN - PENTHOUSE

GI120 BLDG 47 - LIFE SAFETY PLAN - BASEMENT

GI121 BLDG 47 - LIFE SAFETY PLAN - FIRST FLOOR

GI122 BLDG 47 - LIFE SAFETY PLAN - SECOND FLOOR

GI123 BLDG 47 - LIFE SAFETY PLAN - THIRD FLOOR

GI124 BLDG 47 - LIFE SAFETY PLAN - PENTHOUSE

CIVIL

CA001 CIVIL NOTES

CD101 DEMOLITION PLAN

CS101 SITE PLAN

CG101 GRADING PLAN

CG201 EROSION CONTROL PLAN

CU101 UTILITY PLAN

CK501 DETAILS

CK502 CIVIL DETAILS

STRUCTURAL

S-001 STRUCTURAL GENERAL NOTES

S-002 STRUCTURAL GENERAL NOTES

S-003 STRUCTURAL GENERAL NOTES

S-004 STRUCTURAL GENERAL NOTES

SD101 BLDG 43 - FIRST FLOOR DEMOLITION PLAN

SD102 BLDG 43 - SECOND FLOOR FRAMING DEMOLITION PLAN

SD103 BLDG 43 - THIRD FLOOR FRAMING DEMOLITION PLAN

SD104 BLDG 43 - THIRD FLOOR ROOF FRAMING DEMOLITION PLAN

SD105 BLDG 43 - PENTHOUSE FLOOR FRAMING DEMOLITION PLAN

SD106 BLDG 43 - PENTHOUSE ROOF FRAMING DEMOLITION PLAN

SD110 BLDG 47 - BASEMENT/ FOUNDATION DEMOLITION PLAN

SD111 BLDG 47 - FIRST FLOOR DEMOLITION PLAN

SD112 BLDG 47 - SECOND FLOOR PARTIAL FRAMING DEMOLITION PLAN

SD113 BLDG 47 - THIRD FLOOR PARTIAL FRAMING DEMOLITION PLAN

SD114 BLDG 47 - ROOF / PENTHOUSE FLOOR PARTIAL FRAMING DEMOLITION PLAN

SD115 BLDG 47 - PENTHOUSE MEZZANINE PARTIAL FRAMING DEMOLITION PLAN

SD116 BLDG 47 - PENTHOUSE ROOF FRAMING DEMOLITION PLAN

SD301 BLDG 43 - DEMOLITION BUILDING SECTIONS

SB100 BLDG 43 - FOUNDATION PLAN

SB110 BLDG 47 - FOUNDATION PLAN

SB501 FOUNDATION DETAILS

SB502 FOUNDATION DETAILS

SB503 FOUNDATION DETAILS

SB504 FOUNDATION DETAILS

SB505 FOUNDATION DETAILS

SF101 BLDG 43 - FIRST FLOOR / FOUNDATION PLAN

SF102 BLDG 43 - SECOND FLOOR FRAMING PLAN

SF103 BLDG 43 - THIRD FLOOR FRAMING PLAN

SF104 BLDG 43 - THIRD FLOOR ROOF FRAMING PLAN

SF105 BLDG 43 - PENTHOUSE FLOOR FRAMING PLAN

SF106 BLDG 43 - PENTHOUSE ROOF FRAMING PLAN

SF111 BLDG 47 - FIRST FLOOR FRAMING PLAN

SF112 BLDG 47 - SECOND FLOOR FRAMING PLAN

SF113 BLDG 47 - THIRD FLOOR FRAMING PLAN

SF114 BLDG 47 - ROOF / PENTHOUSE FLOOR FRAMING PLAN

SF115 BLDG 47 - PENTHOUSE ROOF FRAMING PLAN

SF116 ELEVATOR / STAIR TOWER TYPICAL REINFORCING AND MACHINE ROOM AND ROOF

FRAMING PLAN

SF122 BLDG 43 - SECOND FLOOR FRP STRENGTHENING PLAN

SF123 BLDG 43 - THIRD FLOOR FRP STRENGTHENING PLAN

SF132 BLDG 47 - SECOND FLOOR FRP STRENGTHENING PLAN

SF133 BLDG 47 - THIRD FLOOR FRP STRENGTHENING PLAN

SF134 BLDG 47 - ROOF / PENTHOUSE FLOOR FRP STRENGTHENING PLAN

SF135 BLDG 47 - PARTIAL FRP STRENGTHENING PLAN FOR ENLARGING SECOND FLOOR EXISTING

OPENING

SF136 BLDG 47 - PARTIAL FRP STRENGTHENING PLAN FOR ENLARGING THIRD FLOOR EXISTING

OPENING

SF137 PARTIAL FRP STRENGTHENING PLANS

SF501 COLUMN ENCASEMENT DETAILS

SF502 NEW COLUMN DETAILS

SF511 CMU WALL DETAILS

SF512 CMU AND CONCRETE WALL DETAILS

SF513 ELEVATOR / STAIR TOWER SECTIONS

SF514 ELEVATOR / STAIR TOWER SECTIONS

SF515 CMU AND CONCRETE WALL DETAILS

SF521 BEAM DETAILS

SF522 BEAM DETAILS

SF523 BEAM AND PLATFORM DETAILS

SF531 FRP STRENGTHENING DETAILS

SF541 AT / FP DETAILS

SF542 AT / FP DETAILS

SF543 AT / FP DETAILS

SF551 STAIR AND ELEVATOR DETAILS

SF561 MISCELLANEOUS DETAILS

SF571 EQUIPMENT HANGER DETAILS

SF581 STRUCTURAL REPAIR DETAILS

SF601 COLUMN SCHEDULES

SF611 BEAM SCHEDULES

SF641 BLDG 43 - LIVE LOAD DIAGRAM PLANS

SF642 BLDG 43 - LIVE LOAD DIAGRAM PLANS

SF643 BLDG 47 - LIVE LOAD DIAGRAM PLANS

SF644 BLDG 47 - LIVE LOAD DIAGRAM PLANS

VOLUME 1 of 3 VOLUME 2 of 3

VOLUME 3 of 3

GENERAL SYMBOLSSECTION SYMBOLS

MATERIAL INDICATIONS

STANDARD ABBREVIATIONS

GENERAL NOTES

EARTH

CONCRETE

GRAVEL

BRICK

METAL

PLYWOOD

WOOD (FINISH)

WOOD (ROUGH)

CRUSHED ROCK

PLASTER

GLASS (ELEVATION)

BLANKET INSULATION

RIGID INSULATION

GYPSUM WALLBOARD

CONCRETE MASONRY UNITS

MARBLE

STONE (ELEVATION)

STONE (SECTION)

WOOD (SURFACE)

WALL SECTION SYMBOL

FULL BUILDING SECTION SYMBOL

EXTERIOR ELEVATION SYMBOL

INTERIOR ELEVATION SYMBOL

A-XXX

X

SHEET NUMBER WHERE ELEVATION IS

SHOWN *

SHEET NUMBER WHERE ELEVATION IS

SHOWN *

DIRECTION OF SIGHT OF ELEVATION ON

PLAN

SHEET NUMBER WHERE ELEVATION IS

SHOWN

DIRECTION OF SIGHT OF ELEVATION ON

PLAN

DIRECTION OF SIGHT OF ELEVATION ON PLAN

A-XXX

X

A-XXX

X

A-XXX

X

DETAIL SECTION SYMBOL

SHEET NUMBER WHERE ELEVATION IS

SHOWN *

DIRECTION OF SIGHT OF ELEVATION ON

PLAN

A-XXX

X

A-XXX

DIRECTION OF SIGHT OF ELEVATION ON

PLAN

SHEET NUMBER WHERE ELEVATION IS

SHOWN

ROOM NAME AND NUMBER

DOOR NUMBERS

COLUMN LINES NUMBER-LETTER

(OPPOSITE DIR.)

MATCH LINE INDICATOR

WINDOW TYPES

CENTER LINE

DIRECTION OF PHOTOGRAPH

VIEW

WALL AND PARTITION TYPES

KEYNOTE INDICATOR

REVISION SYMBOL

DETAIL INDICATOR

CENTERLINE INDICATOR

LOUVER TYPES

ELEVATION INDICATOR

SLOPE ARROW

SCALE BAR

STANDARD NORTH ARROW

DRAWING TITLE BAR

150 SF

ROOM NAME

CODE1

150 SF

A1

101 A

1t

1i

SEE XX-XXX

MACTH LINE

X

X

X-XXX

SIM

1t

NTRUE

NORTH

DRAWING TITLE

X

1/8" = 1'-0"

ROOM CODE

ACTUAL AREA

REQUIRED AREA

4'

SCALE : 1/8" = 1'-0"

0 8' 16'

1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS

ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.

2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY APPEAR IN THIS SET OF DRAWINGS TO

INDICATE SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

E S T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I N

T E

R I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

5 6 7 8 9

STAMP

7/27/2017 2:12:53 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI003

T en th

S tr ee t N

.E

S u it e

A tl an ta

G A

U

SA

T el

-8

-8

F ax

-8

-8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs ity S q

H u n ts v ill e A

L

L E

G E

N D

A N

D A

B B

R E

V

IA

T

IO

N S

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

V .P

A T

E L

L .W

R

IG

H T

L .W

R

IG

H T

J U

L Y

L .W

R

IG

H T

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

T TREAD

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

TC TOP OF CURB

TEL TELEPHONE

TEMP TEMPERATURE

TERR TERRAZZO

TOC TOP OF CONCRETE

TOIL TOILET

TOPO TOPOGRAPHY

TOS TOP OF STEEL

TOW TOP OF WALL

TP TOP OF PAVEMENT

TRANS TRANSVERSE

TYP TYPICAL

UC UNDERCUT

UG UNDERGROUND

UH UNIT HEATER

UR URINAL

UV UNIT VENTILATOR

V VOLT

VB VINYL BASE

VC VERTICAL CURVE

VCP VITRIFIED CLAY PIPE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VFD VARIABLE FREQUENCY DRIVE

VIF VERIFY IN FIELD

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W WATT

W/ WITH

W/O WITHOUT

WC WATER CLOSET OR WALL COVERING

WD WOOD

WDW WINDOW

WH WATER HEATER

WP WEATHERPROOF

WPFG WATERPROOFING

WS WATER STOP

WT WEIGHT

WWF WELDED WIRE FABRIC

XFMR TRANSFORMER

YD YARD

YH YARD HYDRANT

MET METAL

MFR MANUFACTURE

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MLO MAIN LUGS ONLY

MM MILLIMETER

MO MASONRY OPENING

MTG MOUNTING OR MOUNTED

MULL MULLION

NEC NATIONAL ELECTRICAL CODE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

O/S OFFSET

OA OUTSIDE AIR

OC ON CENTER

OD OUTSIDE DIAMETER

OF OUTSIDE FACE

OPNG OPENING

OPP OPPOSITE

OSS OVERFLOW STORM SEWER

OZ OUNCE

P PAINT OR PUMP OR PENDANT

PA PASCAL

PART PARTITION

PAVT PAVEMENT

PC POINT OF CURVATURE

PCF POUNDS PER CUBIC FOOT

PED PEDESTAL

PERP PERPENDICULAR

PHC PREHEAT COIL

PHVAC PLUMBING, HEATING, VENTILATING AND AIR

CONDITIONING

PI POINT OF INTERSECTION

PIV POST INDICATOR VALVE

PKG PARKING

PL PROPERTY LINE OR PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLF POUINDS PER LINEAR FOOT

PLYWD PLYWOOD

PNL PANEL

PNT PAINT

PR PAIR

PROJ PROJECTION

PRV PRESSURE REGULATING VALVE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED

PTVC POINT OF VERTICAL CURVATURE

PVC POLYVINYL CHLORIDE

PVI POINT OF VERTICAL INTERSECTION

PVT POINT OF VERTICAL TANGENCY

QT QUARRY TILE

R RADIUS

RA RETURN AIR

RB RESILIENT BASE

RCP REINFORCED CONCRETE PIPE

RD ROOF DRAIN

REF REFERENCE

REFL REFLECTED

REG REGISTER

REINF REINFORCING

REQD REQUIRED

REV REVERSE

RF RETURN FAN

RGS RIGID GALVANIZED STEEL

RH ROOF HOOD

RHC REHEAT COIL

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

S STAIR OR STAIN OR SURFACE

SA SUPPLY AIR OR SOUND ATTENUATOR

SAN SANITARY

SCH SCHEDULE

SECT SECTION

SF SQUARE FOOT

SHT SHEET

SIM SIMILAR

SK SINK

SOG SLAB-ON-GRADE

SP SUMP PUMP

SPEC SPECIFICATIONS

SQ SQUARE

SS SERVICE SINK

SSTL STAINLESS STEEL

STA STATION

STD STANDARD

STE STANDARD TAPERED END

STIFF STIFFENER

STIR STIRRUP

STL STEEL

STN STAIN

STOR STORAGE

STR STRUCTURAL

SUSP SUSPENDED

SVF SHEET VINYL FLOORING

SW SWITCH

SWGR SWITCHGEAR

SYM SYMMETRICAL

EXH EXHAUST

EXIST EXISTING

EXP EXPOSED

EXPN EXPANSION

EXT EXTERIOR

FA FIRE ALARM

FARX FIRE ALARM RADIO TRANSCEIVER

FCU FAN COIL UNIT

FD FLOOR DRAIN OR FIRE DAMPER

FDN FOUNDATION

FDR FEEDER

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF&E FURNITURE, FIXTURE, AND EQUIPMENT

FH FIRE HYDRANT

FHC FIRE HOSE CABINET

FIN FINISH

FIX FIXTURE

FL FLOOR

FLCO FLOOR CLEANOUT

FM FORCE MAIN

FP FIREPROOFING

FR FIRE RATED

FRP FIBERGLASS REINFORCED PLASTIC

FT FEET

FTG FOOTING

FVC FIRE VALE CABINET

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GEN GENERATOR

GFRC GLASS FIBER REINFORCED CONCRETE

GI GALVANIZED IRON

GL GLASS

GLB GLASS BLOCK

GP GLAZED PAINT

GPM GALLONS PER MINUTE

GR GRADE

GWB GYPSUM WALLBOARD

GYP GYPSUM

HB HOSE BIBB

HC HEATING COIL

HDCP HANDICAP (PED)

HDNR HARDENER

HDW HARDWARE

HDWD HARDWOOD

HK1E HOOK ONE END

HK2E HOOK TWO ENDS

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HORSEPOWER

HPT HIGH POINT

HR HOUR

HS HIGH STRENGTH

HT HEIGHT

HTG HEATING

HTR HEATER

HVAC HEATING/VENTILATING/AIR CONDITIONING

HZ HERTZ

IC INTERCOM

ID INSIDE DIAMETER

IE INVERT ELEVATION

IF INSIDE FACE

IN IN

INSUL INSULATION

INT INTERIOR

JAN JANITOR

JB JUNCTION BOX

JST JOIST

JT JOINT

KCJ KEYED CONSTRUCTION JOINT

KCMIL THOUSAND CIRCULAR MILS

KIT KITCHEN

KS KITCHEN SINK

KV KILOVOLT

KVA KILOVOLT AMPERE

KW KILOWATTS

LAB LABORATORY

LAM LAMINATE

LAV LAVATORY

LBS POUNDS

LF LINEAR FEET

LGC LIQUID GLAZED EPOXY COATING

LIN LINEAR

LL LIVE LOAD

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMU LIGHTWEIGHT MASONRY UNITS

LONG LONGITUDINAL

LT LIGHT

LT WT LIGHT WEIGHT

LTG LIGHTING

LVL LEVEL

M METER

M2 SQUARE METER

M3 CUBIC METER

MAINT MAINTENANCE

MAR MARBLE

MAS MASONRY

MAT MATERIAL

MAX MAXIMUM

MDO MEDIUM DENSITY OVERLAY

MECH MECHANICAL

A/C AIR CONDITIONING

AB ANCHOR BOLT

ABS ACRYLONITRILE-BUTADIENE-STYRENE

AC ALTERNATING CURRENT

ACP ASBESTOS CEMENT PIPE

AD AREA DRAIN

ADJ ADJACENT OR ADJUSTABLE

ADR ACCESS DOOR

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

AL ALTERNATE

ALUM ALUMINUM

ANZ ANODIZED

APPROX APPROXIMATELY

APT APARTMENT

ARCH ARCHITECT(URAL)

ASPH ASPHALT

ATB AIR TERMINAL BOX

ATC ACOUSTICAL TILE CEILING

AUX AUXILIARY

AVG AVERAGE

AZ AZIMUTH

BB BALLED AND BURLAPPED

BD BOARD

BL BUILDING LINE

BLDG BUILDING

BLKG BLOCKING

BM BENCH MARK OR BEAM

BR BARE ROOT

BRG BEARING

BTU BRITISH THERMAL UNIT

C CONDUIT

C/C CENTER TO CENTER

CAB CABINET

CB CIRCUIT BREAKER OR CATCH BASIN

CC COOLING COIL

CDU COVER ELEVATION

CEM CEMENT

CFM CUBIC FEET PER MINUTE

CFS CORNER GUARD

CH CHILLER

CI CURB INLET OR CAST IRON

CIP CAST IRON PIPE

CJ CONTROL JOINT

CKT CIRCUIT

CL CENTER LINE

CLG CEILING

CLO CLOSET

CLR CLEAR

CM CENTIMETER

CMH CUBIC METER PER HOUR

CMP CORRUGATED METAL PIPE

CMT CERAMIC MOSAIC TILE

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COMB COMBINATION OR COMBINE

COMP COMPRESSIBLE

CONC CONCRETE

CONN CONNECTION

CONST CONSTRUCTION

CONT CONTINUOUS OR CONTINUATION

CONTR CONTRACTOR

CORR CORRIDOR

CP CEMENT PIPE

CPT CARPET

CT CERAMIC TILE

CTR CENTER

CUH CABINET UNIT HEATER

CUYD CUBIC YARD

DBL DOUBLE

DCA DENTAL COMPRESSED AIR

DEPR DEPRESSED

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIFF DIFFUSER

DIP DUCTILE IRON PIPE

DISC DISCONNECT

DISP DISPENSER

DIST DISTRIBUTION

DK DECK

DL DEAD LOAD

DLV DENTAL VACUUM

DN DOWN

DO DITTO

DR DOOR

DS DOWNSPOUT

DWG DRAWING

DWL DOWEL

DWP DOMESTIC WATER PUMP

EA EACH

EF EACH FACE OR EXHUAST FAN

EIFS EXTERIOR INSULATION FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC (AL)

ELEV ELEVATOR

EMBED EMBEDMENT

EMD ESTIMATED MAXIMUM DEMAND

EMT ELECTRTICAL METAL TUBING

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

PROJECT

SITE

STREET VIEW

CITY VIEW8901 WISCONSIN AVE., BETHESDA, MD 20889

N

N

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

E S T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I N

T E

R I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

5 6 7 8 9

STAMP

7/27/2017 2:12:54 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI004

T en th

S tr ee t N

.E

S u it e

A tl an ta

G A

U

SA

T el

-8

-8

F ax

-8

-8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs ity S q

H u n ts v ill e A

L

L O

C A

T

IO

N M

A P

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

V .P

A T

E L

L .W

R

IG

H T

L .W

R

IG

H T

J U

L Y

L .W

R

IG

H T

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

DN

W B

A A S H T O

(U S c

T ra n s o f t

S o l ut i o n s

I n c A l l r i g h t s r e s e r v e d

E E

E E

GRAVEL PAD

CONCRETE

CO

CO

CO

CB

A

BLDG 43/47

BLDG 42A

BLDG 42B

BLDG

42C

BLDG 46

BLDG 45

BLDG 42

30' - 0"

30' - 0"

IMAGINARY LOT LINE - SHOWN WITH

30 FT. FIRE SEPARATION DISTANCE

EXISTING AFRRI FIRE

ALARM CONTROL PANEL

NEW BLDG 43/47

COMBINATION FIRE ALARM

MASS NOTIFICATION SYSTEM

CONTROL PANEL

FIRE DEPARTMENT

CONNECTION

LOCAL OPERATING CONSOLE,

ANNUNCIATOR, AND FIRE

FIGHTERS' SMOKE CONTROL

STATION LOCATION

(BASEMENT LEVEL ELEVATOR

LOBBY)

BLDG 47 STAIR 1 CLASS I

COMBINATION

SPRINKLER STANDPIPE

BLDG 47 STAIR 2 CLASS I

STANDPIPE

BLDG 43 STAIR 1 CLASS I

STANDPIPE

FIRE HYDRANT

FIRE HYDRANT

8" NORTH WATER

LINE LEAD-IN POST

INDICATOR VALVE

8" SOUTH WATER

LINE LEAD-IN POST

INDICATOR VALVE

FIRE HYDRANT

FIRE HYDRANT

FIRE HYDRANT

FIRE HYDRANT

2-HOUR FIRE WALL

(BUILDING SEPARATION)

FIRE DEPARTMENT

ACCESS ROUTE

FIRE DEPARTMENT

ACCESS ROUTE

8"

6"

12"

6"

8"

8"

8"

6"

8"

DOMESTIC WATER LINE (FOR

REFERENCE) - SEE SITE

UTILITY PLANS FOR DETAILED

INFO

20' M

IN

20' M

IN

20' MIN.

20' MIN.

APPLICABLE CODES AND STANDARDS

UNITED FACILITIES CRITERIA, GENERAL BUILDING REQUIREMENTS (CHANGE 3, 1 AUGUST 2015)UFC 1-200-01

UNITED FACILITIES CRITERIA, FIRE PROTECTION ENGINEERING FOR FACILITIES (8 AUGUST 2016)UFC 3-600-01

UNITED FACILITIES CRITERIA, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS (CHANGE 1, JANUARY 2010)UFC 4-021-01

INTERNATIONAL BUILDING CODE (2015 EDITION)IBC

NATIONAL FIRE PROTECTION ASSOCIATION, FIRE CODE (2015 EDITION)NFPA 1

NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS (2013 EDITION)NFPA 10

NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS & THEIR APPURTENANCES (2016 EDITION)NFPA 24

NATIONAL FIRE PROTECTION ASSOCIATION, NATIONAL ELECTRICAL CODE (2014 EDITION)UFC 70

NATIONAL FIRE PROTECTION ASSOCIATION, NATIONAL FIRE ALARM & SIGNALING CODE (2016 EDITION)UFC 72

NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING & VENTILATING SYSTEMS (2015 EDITION)NFPA 90A

NATIONAL FIRE PROTECTION ASSOCIATION, LIFE SAFETY CODE (2015 EDITION)NFPA 101

UNITED FACILITIES CRITERIA, DESIGN: MILITARY MEDICAL FACILITIES (CHANGE 1, MAY 2016)UFC 4-510-01

STANDARD ON FIRE AND LIFE SAFETY IN ANIMAL HOUSING FACILITIES (2016 EDITION)NFPA 150

NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (2016 EDITION)NFPA 13

NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS (2016 EDITION)NFPA 14

1. SITE FIRE PROTECTION FEATURES SHALL BE IN ACCORDANCE WITH UFC 3-600-01.

2. REFERENCE GI-SERIES SHEETS FOR BUILDING AND LIFE SAFETY CODE COMPLIANCE

PLANS.

3. REFERENCE FA-SERIES SHEETS FOR FIRE ALARM AND SMOKE CONTROL SYSTEM PLANS.

4. REFERENCE FX-SERIES SHEETS FOR FIRE SUPPRESSION SYSTEM PLANS.

SITE FIRE PROTECTION PLAN - GENERAL NOTES

NTRUE

NORTH

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

KEY PLAN

E S

T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

43E

5 6 7 8 9

43W

42A

42B42C

7/12/2017 11:43:26 AM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI005

T e n th

S tr e e t N

.E S u it e

A tl a n ta G

A

U S

A T e l

-8

-8

F a x

-8 -8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs it y S q

H u n ts v ill e A

L

F

IR

E P

R O

T E

C T

IO

N

L

IF

E S

A F

E T

Y S

IT

E

P L A

N

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

A .S

C H

IE

B

E R

A .S

C H

IE

B

E R

D .G

O L D

B E

R G

J U

L Y

A .S

C H

IE

B

E R

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

1" = 40'-0" A2

SITE FIRE PROTECTION PLAN

SCALE : 1" = 40'-0"

0 40' 80'20'

FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING

ELEMENTS: TYPE II-B

RATING (HOURS)BUILDING ELEMENT

0PRIMARY STRUCTURAL FRAME

NOTE

#2

0 / 2BEARING WALLS: EXTERIOR #3

0BEARING WALLS: INTERIOR -

0 / 2NONBEARING WALLS: EXTERIOR

0NONBEARING WALLS: INTERIOR -

0 / 1FLOOR CONSTRUCTION #4 & #5

0ROOF CONSTRUCTION #4

NOTES:

1. FIRE-RESISTANCE RATINGS ARE BASED OFF OF IBC TABLES 601

AND 602. SEE LIFE SAFETY PLANS FOR LOCATIONS OF RATED

PARTITIONS FOR ACCOMMODATION OF LIFE SAFETY CODE

REQUIREMENTS.

2. PRIMARY STRUCTURAL FRAME CONSISTS OF MEMBERS HAVING

DIRECT CONNECTION TO OTHERS DESIGNED TO CARRY GRAVITY

LOADS. SEE ARCHITECTURAL AND STRUCTURAL SHEETS FOR

SPECIFIC APPLICATION OF EACH ASSEMBLY.

3. EXTERIOR WALL RATING REQUIREMENTS ARE BASED OFF OF FIRE

SEPARATION DISTANCE AND THE REQUIREMENTS OF IBC TABLE 602.

THE EXISTING FACILITY ABUTS BUILDINGS 42 AND 45 AND ARE

PROVIDED WITH 2-HOUR FIRE WALLS AS A MEANS OF BUILDING

SEPARATION IN ACCORDANCE WITH IBC §706.

4. RATING REQUIREMENT FOR FLOOR AND ROOF CONSTRUCTION

INCLUDES SUPPORTING BEAMS AND JOISTS.

5. 1-HOUR FIRE-RESISTANT RATED FLOOR ASSEMBLIES ARE

PROVIDED IN CERTAIN AREAS TO PROVIDE THREE DIMENSIONAL

SEPARATION BETWEEN ANIMAL HOUSING AREAS AND HAZARDOUS

AREAS LOCATED ON ADJACENT STORIES.

#3

OCCUPANCY CLASSIFICATION (IBC)

Group B

Group S-2

BUILDING SEPARATION LEGEND

2-HOUR FIRE WALL

NTRUE

NORTH

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

KEY PLAN

E S

T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

43E

5 6 7 8 9

43W

42A

42B42C

7/12/2017 12:34:08 PM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI006

T e n th

S tr e e t N

.E S u it e

A tl a n ta G

A

U S

A T e l

-8

-8

F a x

-8 -8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs it y S q

H u n ts v ill e A

L

B U

IL

D

IN

G

C O

D E

A N

A L A

Y S

IS

A

N D

G E

N E

R A

L N

O T

E S

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

A .S

C H

IE

B

E R

A .S

C H

IE

B

E R

D .G

O L D

B E

R G

J U

L Y

A .S

C H

IE

B

E R

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

1" = 40'-0" F1

IBC OCCUPANCY CLASSIFICATION - BASEMENT

1" = 40'-0" C1

IBC OCCUPANCY CLASSIFICATION - FIRST FLOOR

OCCUPANCY CLASSIFICATION SCHEDULE

Occupancy Classification (IBC) Area

BASEMENT

MIXED, NONSEPARATED (GROUPS B & S-2)

Group B 1,064 SF

Group S-2 1,984 SF

3,049 SF

FIRST FLOOR

MIXED, NONSEPARATED (GROUPS B & S-2)

Group B 6,808 SF

Group S-2 11,392 SF

18,200 SF

SECOND FLOOR

MIXED, NONSEPARATED (GROUPS B & S-2)

Group B 3,445 SF

Group S-2 12,103 SF

15,548 SF

THIRD FLOOR

MIXED, NONSEPARATED (GROUPS B & S-2)

Group B 3,492 SF

Group S-2 9,401 SF

12,892 SF

PENTHOUSE

SINGLE OCCUPANCY (GROUP S-2)

Group S-2 9,128 SF

9,128 SF

58,817 SF

ALLOWABLE AREA ANALYSIS

Occupancy Classification Most

Restrictive

Building Construction

Type Full Sprinkler Protection?

Allowable Area - IBC

Allowable Area - NFPA

150 Actual Area

BASEMENT

Group B II-B Yes 69,000 SF NA 3,049 SF

FIRST FLOOR

Group B II-B Yes 69,000 SF 46,000 SF 18,200 SF

SECOND FLOOR

Group B II-B Yes 69,000 SF 46,000 SF 15,548 SF

THIRD FLOOR

Group B II-B Yes 69,000 SF 46,000 SF 12,892 SF

PENTHOUSE

Group S-2 II-B Yes 69,000 SF NA 9,128 SF

58,817 SF

1" = 40'-0" A1

IBC OCCUPANCY CLASSIFICATION - SECOND FLOOR

1" = 40'-0" F4

IBC OCCUPANCY CLASSIFICATION - THIRD FLOOR

1" = 40'-0" C4

IBC OCCUPANCY CLASSIFICATION - PENTHOUSE

1" = 40'-0" B4

IBC OCCUPANCY CLASSIFICATION - PENTHOUSE ROOF

SCALE : 1" = 40'-0"

0 40' 80'20'

UP

UP

DN

DN UP

UP

UPUP

BLDG 43 BLDG 47

EXISTING BAS OFFICE TO BE

RELOCATED TO NEWLY

RENOVATED SECOND FLOOR

BLDG 48

APPROXIMATE LOCATION OF

OVERHEAD WARM DRAIN TO

BE MAINTAINED DURING

CONSTRUCTION, VIF.

BLDG 45

TEMPORARY PARTITION

AND OR DOORS, 1 HR

RATED CONSTRUCTION

TEMPORARY PARTITION

TEMP PARTITION, 1HR

RATED CONSTRUCTION

MAINTAIN DELIVERY

ACCESS TO BLDG 48

BLDG 43 BLDG 47

BLDG 43 BLDG 47

43P04

BAS OFFICE

43P05

ELECTRICAL

ROOM

43P03

COMM

43P02

SECURITY

EQUIP

43P01

MECHANICAL

ROOM

MECH1

ROOMS SHOWN HATCHED TO BE

COMPLETED FIRST ALONG WITH ALL

RELATED ITEMS - COORDINATE WITH ALL

DICIPLINES.

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

KEY PLAN

E S T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I N

T E

R I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

43E

5 6 7 8 9

STAMP

43W

42A

42B42C

7/27/2017 2:12:59 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI007

T en th

S tr ee t N

.E

S u it e

A tl an ta

G A

U

SA

T el

-8

-8

F ax

-8

-8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs ity S q

H u n ts v ill e A

L

P H

A S

IN

G

P L A

N S

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

V .P

A T

E L

L .W

R

IG

H T

L .W

R

IG

H T

J U

L Y

L .W

R

IG

H T

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

3/64" = 1'-0"

PHASING PLAN - EXISTING FIRST FLOOR

D1

3/64" = 1'-0" D6

PHASING FLOOR PLAN - NEW SECOND FLOOR

1. EXISTING BUILDING 48 TO REMAIN OPERATIONAL DURING CONSTRUCTION,

REFER TO SHEET E-003 & E-004 FOR ELECTRICAL SEPARATION.

2. ALL WORK SHOWN ON SHEET E-003 & E-004 TO BE COMPLETED PRIOR TO

COMMENCEMENT OF WORK.

3. EXISTING BAS OFFICE TO BE RELOCATED TO SECOND FLOOR OF BUILDING 43

WEST.

4. EXISTING WARM DRAIN FROM BUILDING 45 TO REMAIN IN USE DURING

CONSTRUCTION, MARK AND PROTECT. CONTACT ON SITE RADIATION SAFETY FOR

PROCEDURE TO CONTAIN AND OR REPAIR ANY DAMAGED SECTIONS OF DRAIN.

5. PROVIDE TEMPORARY PARTITIONS TO SEPARATE BUILDINGS 48 AND 45.

NOTE:

CP-B.01 CP-B.01CP-B.01

C P

-B .0

C

P -B

.0

C P

-B .0

T D

-B .0

T

D -B

.0

T D

-B .0

T

D -B

.0

DOOR

2' - 8"

STAIR

3' - 0"

120 4

48BS1

DOOR

7' - 4"

47BS1

OCCUPANCY CLASSIFICATION (NFPA)

BUSINESS

INDUSTRIAL, SPECIAL-PURPOSE

COMPOSITE LIFE SAFETY NOTES:

SYMBOL

TRAVEL DISTANCE ROUTE

EGRESS PATH TYPES

TD-X.YY

COMMON PATH OF TRAVEL ROUTECP-X.YY

DEAD-END ROUTEDE-X.YY

NOTE: X = LEVEL

Y = SEQUENTIAL IDENTIFIER

A: EXIT COMPONENT TYPE (DOOR / STAIR)

EXIT COMPONENT TAGS

B: EXIT COMPONENT CLEAR WIDTH [FT-IN]

C: OCCUPANT LOAD CAPACITY [# OF PERSONS]

B

C D

A

E

D: EXPECTED OCCUPANT LOAD [# OF PERSONS]

E: EXIT COMPONENT ID

THE INTENT OF THESE PLANS IS TO SHOW OVERALL EGRESS CONFIGURATION FOR THE BUILDING AND

DEMONSTRATE COMPLIANCE WITH NFPA 101.

HATCHING ON THESE PLANS INDICATES OCCUPANCY CLASSIFICATION IN ACCORDANCE WITH NFPA 101.

GENERIC LINE TYPES FOR BUILDING SEPARATIONS AND OCCUPANCY SEPARATIONS ARE SHOWN ON THIS PLAN FOR AN OVERALL INDICATION OF OCCUPANCY CLASSIFICATION AND SEPARATION. REFER TO DETAILED LIFE

SAFETY PLANS FOR HOURLY RATING OF THESE BARRIERS.

REFER TO SUBSEQUENT ENLARGED LIFE SAFETY SHEETS SHOWING ENLARGED PLANS OF THE AREAS WITHIN THIS SCOPE OF WORK FOR LOCATIONS AND HOURLY RATINGS OF ALL BARRIERS TO BE PROVIDED AND APPLICATION OF

USE CATEGORIES FOR OCCUPANT LOAD CALCULATIONS.

A ZONED SMOKE CONTROL SYSTEM IS PROVIDED FOR THE FACILITY AS REQUIRED BY NFPA 150 SECTION 9.8.2. THE SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 92 AND SHALL MAINTAIN A MINIMUM PRESSURE DIFFERENCE OF 12.5 PA AND A MAXIMUM PRESSURE DIFFERENCE OF 75 PA ACROSS SMOKE CONTROL ZONE BOUNDARIES WHEN THE SYSTEM IS IN OPERATION. REFER TO FIRE ALARM AND HVAC SYSTEM PLANS FOR

ADDITIONAL INFORMATION.

LIFE SAFETY SYMBOLS:

DESCRIPTION

BUILDING SEPARATION

EXIT DISCHARGE

INTERIOR FINISH REQUIREMENTS BY OCCUPANCY

CLASSIFICATION

BUSINESS

FINISH OR INSULATION

MATERIAL

WALL AND CEILING FINISHES

A / BEXIT ENCLOSURES

A / BEXIT ACCESS CORRIDORS

A / B / CALL OTHER AREAS

FLOOR FINISHES

0 / 1

NOTES:

1. REFER TO ARCHITECTURAL SHEETS AND SPECIFICATIONS FOR FINISH MATERIALS AND RATINGS TO

BE USED.

2. IN ACCORDANCE WITH FOOTNOTE 6 TO NFPA TABLE A.10.2.2, DUE TO THE PRESENCE OF A

COMPLETE SPRINKLER SYSTEM, INTERIOR WALL AND CEILING FINISH WITH A FLAME SPREAD

RATING NOT EXCEEDING CLASS C IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS B IS REQUIRED, AND CLASS B INTERIOR WALL AND CEILING FINISH MATERIAL IS PERMITTED TO BE USED

IN ANY LOCATION WHERE CLASS A IS REQUIRED.

3. SIMILARLY, CLASS II INTERIOR FLOOR FINISH IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS I IS REQUIRED, AND NO INTERIOR FLOOR FINISH CLASSIFICATION IS REQUIRED WHERE CLASS

II IS REQUIRED.

CLASS I / IIEXIT ENCLOSURES

CLASS I / IIEXIT ACCESS CORRIDORS

NO CRITERIAALL OTHER AREAS

INSULATION MATERIALS

INDUSTRIAL,

SPECIAL-

PURPOSE

THERMAL/ACOUSTIC

INSULATION

A / B

A / B / C

A / B / C

0 / 1

CLASS I / II

CLASS I / II

NO CRITERIA

0 / 1

CLASS I / II

NO CRITERIA

A / B

A / B / C

A / B / C

ORDINARY

HAZARD

STORAGE

FLAME SPREAD RATING < 75

SMOKE DEVELOPED INDEX ≤ 150

NTRUE

NORTH

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

KEY PLAN

E S

T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

43E

5 6 7 8 9

43W

42A

42B42C

7/12/2017 11:43:44 AM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI100

T e n th

S tr e e t N

.E S u it e

A tl a n ta G

A

U S

A T e l

-8

-8

F a x

-8 -8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs it y S q

H u n ts v ill e A

L

C O

M P

O S

IT

E

L

IF

E S

A F

E T

Y P

L A

N

B A

S E

M E

N T

W

IS

C

O N

S

IN

A V

E B

E T

H E

S D

A M

D

A R

C H

IT

E

C T

U R

A L A

N D

E N

G

IN

E E

R

IN

G S

E R

V

IC

E S

A R

M E

D F

O R

C E

S R

A D

IO

B

IO

L O

G Y

R E

S E

A R

C H

IN

S

T

IT

U T

E

A F

R R

I) B

L D

G /4

D

E S

IG

N

A .S

C H

IE

B

E R

A .S

C H

IE

B

E R

D .G

O L D

B E

R G

J U

L Y

A .S

C H

IE

B

E R

X X

X X

X X

-X X

-X -X

X X

X

W D

Y -1

-D

-0

BLDG 43/47

1/16" = 1'-0" D1

COMPOSITE LIFE SAFETY PLAN - BASEMENT

MEANS OF EGRESS ARRANGEMENT - BASEMENT

Egress Path Name Occupancy Classification

Egress Path Length

Egress Path Maximum Permitted

CP-B.01 INDUSTRIAL, SPECIAL-PURPOSE 65' - 0" 100' - 0"

TD-B.01 BUSINESS 50' - 1" 300' - 0"

OCCUPANT LOAD CALCULATION - BASEMENT

Occupant Load Factor Use Category Area Occupant Load

Factor [SF/Person] Occupant

Load

MIXED, NONSEPARATED (GROUPS B & S-2)

Business Use - General 1,000 SF 100 10

Mechanical, Electrical, Other Building Equipment Spaces 2,049 SF 500 4

3,049 SF 14

EXIT CAPACITY COMPARISON - BASEMENT

Most Restrictive Egress Component Expected Occupant

LoadID Type Clear Width

Capacity Factor (in/Person)

Occupant Capacity

48BS1 Stair 3' - 0" 0.3 120 4

47BS1 Door 7' - 4" 0.2 440 10

560 14

8'

SCALE : 1/16" = 1'-0"

0 16' 32'

DN

CP-1.02CP-1.02

C P

-1 .0

C

P -1

.0

DOOR

5' - 4"

47413

DOOR

2' - 8"

E608

DOOR

2' - 8"

E609

DOOR

2' - 8"

47445

STAIR

4' - 0"

160 35

47S1

T D

-1 .0

T

D -1

.0

TD-1.01 TD-1.01TD-1.01

TD-1.01 TD-1.01TD-1.01 TD-1.01 TD-1.01

T D

-1 .0

T

D -1

.0

T D

-1 .0

T

D -1

.0

T D

-1 .0

T

D -1

.0

T D

-1 .0

TD-1.03TD-1.03

T D

-1 .0

T

D -1

.0

T D

-1 .0

TD-1.03 TD-1.03TD-1.03

TD-1.04TD-1.04

T D

-1 .0

T

D -1

.0

TD-1.04TD-1.04 TD-1.04TD-1.04TD-1.04

C P

-1 .0

1C P

-1 .0

TD-1.05TD-1.05

T D

-1 .0

T

D -1

.0

DOOR

2' - 8"

47453

DOOR

2' - 8"

431S1A

DOOR

2' - 8"

47454

OCCUPANCY CLASSIFICATION (NFPA)

BUSINESS

INDUSTRIAL, SPECIAL-PURPOSE

STORAGE, LOW & ORDINARY HAZARD

TO BUILDING 45

COMPOSITE LIFE SAFETY NOTES:

SYMBOL

TRAVEL DISTANCE ROUTE

EGRESS PATH TYPES

TD-X.YY

COMMON PATH OF TRAVEL ROUTECP-X.YY

DEAD-END ROUTEDE-X.YY

NOTE: X = LEVEL

Y = SEQUENTIAL IDENTIFIER

A: EXIT COMPONENT TYPE (DOOR / STAIR)

EXIT COMPONENT TAGS

B: EXIT COMPONENT CLEAR WIDTH [FT-IN]

C: OCCUPANT LOAD CAPACITY [# OF PERSONS]

B

C D

A

E

D: EXPECTED OCCUPANT LOAD [# OF PERSONS]

E: EXIT COMPONENT ID

THE INTENT OF THESE PLANS IS TO SHOW OVERALL EGRESS CONFIGURATION FOR THE BUILDING AND

DEMONSTRATE COMPLIANCE WITH NFPA 101.

HATCHING ON THESE PLANS INDICATES OCCUPANCY CLASSIFICATION IN ACCORDANCE WITH NFPA 101.

GENERIC LINE TYPES FOR BUILDING SEPARATIONS AND OCCUPANCY SEPARATIONS ARE SHOWN ON THIS PLAN FOR AN OVERALL INDICATION OF OCCUPANCY CLASSIFICATION AND SEPARATION. REFER TO DETAILED LIFE

SAFETY PLANS FOR HOURLY RATING OF THESE BARRIERS.

REFER TO SUBSEQUENT ENLARGED LIFE SAFETY SHEETS SHOWING ENLARGED PLANS OF THE AREAS WITHIN THIS SCOPE OF WORK FOR LOCATIONS AND HOURLY RATINGS OF ALL BARRIERS TO BE PROVIDED AND APPLICATION OF

USE CATEGORIES FOR OCCUPANT LOAD CALCULATIONS.

A ZONED SMOKE CONTROL SYSTEM IS PROVIDED FOR THE FACILITY AS REQUIRED BY NFPA 150 SECTION 9.8.2. THE SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 92 AND SHALL MAINTAIN A MINIMUM PRESSURE DIFFERENCE OF 12.5 PA AND A MAXIMUM PRESSURE DIFFERENCE OF 75 PA ACROSS SMOKE CONTROL ZONE BOUNDARIES WHEN THE SYSTEM IS IN OPERATION. REFER TO FIRE ALARM AND HVAC SYSTEM PLANS FOR

ADDITIONAL INFORMATION.

LIFE SAFETY SYMBOLS:

DESCRIPTION

BUILDING SEPARATION

EXIT DISCHARGE

INTERIOR FINISH REQUIREMENTS BY OCCUPANCY

CLASSIFICATION

BUSINESS

FINISH OR INSULATION

MATERIAL

WALL AND CEILING FINISHES

A / BEXIT ENCLOSURES

A / BEXIT ACCESS CORRIDORS

A / B / CALL OTHER AREAS

FLOOR FINISHES

0 / 1

NOTES:

1. REFER TO ARCHITECTURAL SHEETS AND SPECIFICATIONS FOR FINISH MATERIALS AND RATINGS TO

BE USED.

2. IN ACCORDANCE WITH FOOTNOTE 6 TO NFPA TABLE A.10.2.2, DUE TO THE PRESENCE OF A

COMPLETE SPRINKLER SYSTEM, INTERIOR WALL AND CEILING FINISH WITH A FLAME SPREAD

RATING NOT EXCEEDING CLASS C IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS B IS REQUIRED, AND CLASS B INTERIOR WALL AND CEILING FINISH MATERIAL IS PERMITTED TO BE USED

IN ANY LOCATION WHERE CLASS A IS REQUIRED.

3. SIMILARLY, CLASS II INTERIOR FLOOR FINISH IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS I IS REQUIRED, AND NO INTERIOR FLOOR FINISH CLASSIFICATION IS REQUIRED WHERE CLASS

II IS REQUIRED.

CLASS I / IIEXIT ENCLOSURES

CLASS I / IIEXIT ACCESS CORRIDORS

NO CRITERIAALL OTHER AREAS

INSULATION MATERIALS

INDUSTRIAL,

SPECIAL-

PURPOSE

THERMAL/ACOUSTIC

INSULATION

A / B

A / B / C

A / B / C

0 / 1

CLASS I / II

CLASS I / II

NO CRITERIA

0 / 1

CLASS I / II

NO CRITERIA

A / B

A / B / C

A / B / C

ORDINARY

HAZARD

STORAGE

FLAME SPREAD RATING < 75

SMOKE DEVELOPED INDEX ≤ 150

NTRUE

NORTH

D A

T E

SHEET ID

IF SHEET MEASURES LESS THAN 22" X 34" IT IS A

REDUCED PRINT. REDUCE SCALE ACCORDINGLY

KEY PLAN

E S

T

P L

A N

N I N

G A

R C

H I T

E C

T U

R E

E N

G I N

E E

R I N

G I

N T

E R

I O

R S

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

IS

S

U E

D A

T E

C H

E C

K E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

X

M A

R K

D E

S C

R

IP

T

IO

N

A

B

C

D

E

F

G

1 2 3 4 10

US Army Corps of Engineers ®

43E

5 6 7 8 9

43W

42A

42B42C

7/12/2017 12:34:12 PM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt

LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION

GI101

T e n th

S tr e e t N

.E S u it e

A tl a n ta G

A

U S

A T e l

-8

-8

F a x

-8 -8

U .S

A rm y E n g in e e ri n g a n d

S u p p o rt

C e n te r H u n ts v ill e U n iv e rs it y S q

H u n ts v ill e A

L

C O

M P

O S

IT

E

L

IF

E S

A F

E T

Y P

L A

N

F

IR

S T

F L O

O R

W

IS

C

O…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.