Attachment_4_-_AFRRI_Design_Volume_1.pdf
PDF 46 MB Posted
- Solicitation number
- W9127S18R6031
About this file
AFRRI Design Volume 1
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
E S T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I N
T E
R I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
5 6 7 8 9
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
A R C H I T E C T U R E
E N G I N E E R I N G
I N T E R I O R S
P L A N N I N G
7/27/2017 2:11:17 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI001A
T en th
S tr ee t N
.E
S u it e
A tl an ta
G A
U
SA
T el
-8
-8
F ax
-8
-8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs ity S q
H u n ts v ill e A
L
C O
V E
R S
H E
E T
V
O L U
M E o f
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
V .P
A T
E L
L .W
R
IG
H T
L .W
R
IG
H T
J U
L Y
L .W
R
IG
H T
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
8901 WISCONSIN AVE, BETHESDA, MD 20889
ARCHITECTURAL AND ENGINEERING SERVICES
ARMED FORCES RADIOBIOLOGY RESEARCH
INSTITUTE (AFRRI) BLDG. 43/47 DESIGN
XXXXXX-XX-X-XXXX
W912DY-13-D-0121
JULY 2017
HUNTSVILLE CENTER
VOLUME 1 of 3
D
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
E S T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I N
T E
R I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
5 6 7 8 9
STAMP
7/27/2017 2:12:51 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI002
T en th
S tr ee t N
.E
S u it e
A tl an ta
G A
U
SA
T el
-8
-8
F ax
-8
-8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs ity S q
H u n ts v ill e A
L
S H
E E
T I N
D E
X
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
V .P
A T
E L
L .W
R
IG
H T
L .W
R
IG
H T
J U
L Y
L .W
R
IG
H T
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
ED101 ELECTRICAL DEMOLITION PLAN - BASEMENT AND FIRST FLOOR
ED102 ELECTRICAL DEMOLITION PLAN - SECOND FLOOR
ED103 ELECTRICAL DEMOLITION PLAN - THIRD FLOOR
ED104 ELECTRICAL DEMOLITION PLAN - PENTHOUSES AND ROOF
EP101 BLDG 43 - LIGHTNING PROTECTION PLAN
EP102 BLDG 47 - LIGHTNING PROTECTION PLAN
EP111 BLDG 43 - POWER PLAN - FIRST FLOOR
EP112 BLDG 43 - POWER PLAN - SECOND FLOOR
EP113 BLDG 43 - POWER PLAN - THIRD FLOOR
EP114 BLDG 43 - POWER PLAN - PENTHOUSE
EP120 BLDG 47 - POWER PLAN - BASEMENT
EP121 BLDG 47 - POWER PLAN - FIRST FLOOR
EP122 BLDG 47 - POWER PLAN - SECOND FLOOR
EP123 BLDG 47 - POWER PLAN - THIRD FLOOR
EP124 BLDG 47 - POWER PLAN - PENTHOUSE
EP125 BLDG 43/47 - POWER PLAN - ROOF
EP201 OVERALL MECHANICAL POWER PLAN - FIRST FLOOR
EP202 OVERALL MECHANICAL POWER PLAN - SECOND FLOOR
EP203 OVERALL MECHANICAL POWER PLAN - THIRD FLOOR
EP401 ELECTRICAL LARGE SCALE PLANS
EP402 ELECTRICAL LARGE SCALE PLANS
EP403 ELECTRICAL LARGE SCALE PLANS
EP404 ELECTRICAL LARGE SCALE PLANS - TYPICAL ANIMAL ROOM RACEWAYS
EP405 ELECTRICAL LARGE SCALE PLANS
EP501 ELECTRICAL DETAILS
EP502 ELECTRICAL DETAILS
EP503 ELECTRICAL DETAILS
EP504 ELECTRICAL DETAILS - MAIN ELECTRICAL FEEDERS ROUTING
EP505 ELECTRICAL DETAILS - PRIMARY FEEDERS ROUTING
EP506 ELECTRICAL DETAILS
EP601 ELECTRICAL ONE LINE DIAGRAM
EP602 ELECTRICAL RISER DIAGRAMS
EP603 ELECTRICAL RISER DIAGRAMS
EP604 ELECTRICAL SCHEDULES
EP605 ELECTRICAL SCHEDULES
EP606 ELECTRICAL SCHEDULES
EP607 ELECTRICAL SCHEDULES
EP608 ELECTRICAL SCHEDULES
EP609 ELECTRICAL SCHEDULES
EP610 ELECTRICAL SCHEDULES
EP611 ELECTRICAL SCHEDULES
EP612 ELECTRICAL SCHEDULES
EP613 ELECTRICAL SCHEDULES
EP614 ELECTRICAL SCHEDULES
EP615 ELECTRICAL SCHEDULES
EP616 ELECTRICAL SCHEDULES
EL111 BLDG 43 - LIGHTING PLAN - FIRST FLOOR
EL112 BLDG 43 - LIGHTING PLAN - SECOND FLOOR
EL113 BLDG 43 - LIGHTING PLAN - THIRD FLOOR
EL114 BLDG 43 - LIGHTING PLAN - PENTHOUSE
EL120 BLDG 47 - LIGHTING PLAN - BASEMENT
EL121 BLDG 47 - LIGHTING PLAN - FIRST FLOOR
EL122 BLDG 47 - LIGHTING PLAN - SECOND FLOOR
EL123 BLDG 47 - LIGHTING PLAN - THIRD FLOOR
EL124 BLDG 47 - LIGHTING PLAN - PENTHOUSE
EL501 LIGHTING DETAILS
EL601 LIGHTING FIXTURE SCHEDULE AND CONTROLS
ET111 BLDG 43 - TELECOMMUNICATIONS PLAN - FIRST FLOOR
ET112 BLDG 43 - TELECOMMUNICATIONS PLAN - SECOND FLOOR
ET113 BLDG 43 - TELECOMMUNICATIONS PLAN - THIRD FLOOR
ET114 BLDG 43 - TELECOMMUNICATIONS PLAN - PENTHOUSE
ET120 BLDG 47 - TELECOMMUNICATIONS PLAN - BASEMENT
ET121 BLDG 47 - TELECOMMUNICATIONS PLAN - FIRST FLOOR
ET122 BLDG 47 - TELECOMMUNICATIONS PLAN - SECOND FLOOR
ET123 BLDG 47 - TELECOMMUNICATIONS PLAN - THIRD FLOOR
ET124 BLDG 47 - TELECOMMUNICATIONS PLAN - PENTHOUSE
ET501 TELECOMMUNICATIONS DETAILS
ET511 LOW VOLTAGE SYSTEMS RACEWAY ROUTING - FIRST FLOOR
ET512 LOW VOLTAGE SYSTEMS RACEWAY ROUTING - SECOND FLOOR
ET513 LOW VOLTAGE SYSTEMS RACEWAY ROUTING - THIRD FLOOR
ET601 TELECOMMUNICATIONS DIAGRAMS AND DETAILS
ET602 TELECOMMUNICATIONS DIAGRAMS AND DETAILS
EY111 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - FIRST FLOOR
EY112 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - SECOND FLOOR
EY113 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - THIRD FLOOR
EY114 BLDG 43 - ELECTRONIC SECURITY SYSTEMS - PENTHOUSE
EY120 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - BASEMENT
EY121 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - FIRST FLOOR
EY122 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - SECOND FLOOR
EY123 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - THIRD FLOOR
EY124 BLDG 47 - ELECTRONIC SECURITY SYSTEMS - PENTHOUSE
EY601 ELECTRONIC SECURITY SYSTEM DIAGRAMS AND DETAILS
EY602 ELECTRONIC SECURITY SYSTEM DIAGRAMS AND DETAILS
EY603 ELECTRONIC SECURITY SYSTEM DIAGRAMS AND DETAILS
Grand total: 491
PP221 BLDG 47 - MEDICAL GAS PLAN - BASEMENT
PP222 BLDG 47 - MEDICAL GAS PLAN - FIRST FLOOR
PP223 BLDG 47 - MEDICAL GAS PLAN - SECOND FLOOR
PP224 BLDG 47 - MEDICAL GAS PLAN - THIRD FLOOR
PP225 BLDG 47 - MEDICAL GAS PLAN - PENTHOUSE
PP311 BLDG 43 - PLUMBING PLAN - FIRST FLOOR - ANIMAL WATERING PIPING
PP322 BLDG 47 - PLUMBING PLAN - FIRST FLOOR - ANIMAL WATERING PIPING
PP323 BLDG 47 - PLUMBING PLAN - SECOND FLOOR - ANIMAL WATERING PIPING
PP324 BLDG 47 - PLUMBING PLAN - THIRD FLOOR - ANIMAL WATERING PIPING
PP501 PLUMBING DETAILS
PP502 PLUMBING DETAILS
PP503 PLUMBING DETAILS
PP601 BLDG 43 - DOMESTIC WATER RISER DIAGRAMS
PP602 BLDG 43 INDUSTRIAL WATER RISER DIAGRAM
PP603 BLDG 47 - INDUSTRIAL WATER RISER DIAGRAMS
PP604 BLDG 47 - DOMESTIC WATER RISER DIAGRAMS
PP605 BLDG 43 - SANITARY RISER DIAGRAMS
PP606 BLDG 47 - SANITARY RISER DIAGRAMS
PP607 BLDG 43 - MEDICAL GAS RISER DIAGRAM
PP608 BLDG 47 - MEDICAL GAS RISER DIAGRAM
PP609 ANIMAL WATERING RISER DIAGRAM
PP610 NATURAL GAS RISER DIAGRAM
PP611 BLDG 47 - STORM RISER DIAGRAM
PP701 PLUMBING SCHEDULES
PP702 PLUMBING SCHEDULES
MECHANICAL
M-001 MECHANICAL SYMBOLS, GENERAL NOTES
MD111 BLDG 43 - HVAC DEMO - FIRST FLOOR
MD112 BLDG 43 - HVAC PIPING - SECOND FLOOR
MD113 BLDG 43 - HVAC DEMO - THIRD FLOOR
MD114 BLDG 43 HVAC DEMO - PENTHOUSE
MD115 BLDG 43 - HVAC DEMO - PENTHOUSE ROOF
MD121 BLDG 47 - HVAC AND PIPING DEMOLITION PLAN - FIRST FLOOR
MD122 BLDG 47 - HVAC AND PIPING DEMOLITION PLAN - SECOND FLOOR
MD123 BLDG 47 - HVAC DEMO - THIRD FLOOR
MD124 BLDG 47 - HVAC DEMO - PENTHOUSE
MD125 BLDG 47 - HVAC DEMO - PENTHOUSE ROOF
MH111 BLDG 43 - HVAC PLAN - FIRST FLOOR
MH112 BLDG 43 - HVAC PLAN - SECOND FLOOR
MH113 BLDG 43 - HVAC PLAN - THIRD FLOOR
MH114 BLDG 43 - HVAC PLAN - PENTHOUSE
MH115 BLDG 43 - HVAC PLAN - PENTHOUSE ROOF
MH120 BLDG 47 - HVAC PLAN - BASEMENT
MH121 BLDG 47 - HVAC PLAN - FIRST FLOOR
MH122 BLDG 47 - HVAC PLAN - SECOND FLOOR
MH123 BLDG 47 - HVAC PLAN - THIRD FLOOR
MH124 BLDG 47 - HVAC PLAN - PENTHOUSE
MH125 BLDG 47 - HVAC PLAN - PENTHOUSE ROOF
MH130 BLDG 47 - ROOM PRESSURIZATION PLAN - FIRST FLOOR
MH131 BLDG 47 - ROOM PRESSURIZATION PLAN - SECOND FLOOR
MH132 BLDG 47 - ROOM PRESSURIZATION PLAN - THIRD FLOOR
MH133 BLDG 43 - ROOM PRESSURIZATION PLAN - FIRST FLOOR
MH134 BLDG 43 - ROOM PRESSURIZATION PLAN - SECOND FLOOR
MH135 BLDG 43 -ROOM PRESSURIZATION PLAN - THIRD FLOOR
MH301 BLDG 47 MECHANICAL SECTIONS
MH302 BLDG 47 MECHANICAL SECTIONS
MH303 BLDG 43 MECHANICAL SECTIONS
MH304 BLDG 47 MECHANICAL AIR HANDLING UNIT ELEVATIONS
MH305 BLDG 47 MECHANICAL AIR HANDLING UNIT ELEVATIONS
MH401 BLDG 47 - HVAC LARGE SCALE PLANS AND SECTIONS
MH402 BLDG 43 - HVAC LARGE SCALE PLAN - SECOND FLOOR MECHANCIAL ROOM
MH403 BLDG 43 - HVAC LARGE SCALE PLAN - PENTHOUSE MECHANICAL ROOM
MH501 MECHANICAL DETAILS
MH502 MECHANICAL DETAILS
MH503 MECHANICAL DETAILS
MH601 BLDG 43 MECHANICAL SCHEDULES
MH602 BLDG 43 MECHANICAL SCHEDULES
MH603 BLDG 47 - MECHANICAL SCHEDULES
MH604 BLDG 47 - MECHANICAL SCHEDULES
MH605 BLDG 47 - MECHANICAL SCHEDULES
MH606 BLDG 47 - MECHANICAL SCHEDULES
MH607 BLDG 47 - MECHANICAL SCHEDULES
MH701 HEATING WATER HVAC FLOW DIAGRAM
MH702 STEAM HVAC FLOW DIAGRAM B-47
MH703 HEATING HOT WATER AND CHILLED WATER FLOW DIAGRAM B-43
MH704 STEAM HVAC FLOW DIAGRAM B-43
MH705 HEATING HOT WATER AND CHILLED WATER FLOW DIAGRAM B-47
MH801 HVAC CONTROLS
MH802 HVAC CONTROLS
MH803 HVAC CONTROLS
MH804 HVAC CONTROLS
MH805 HVAC CONTROLS
MH806 HVAC CONTROLS
MH807 HVAC CONTROLS
MH808 HVAC CONTROLS
MH809 HVAC CONTROLS
MH810 HVAC CONTROLS
MH811 HVAC CONTROLS
MH812 HVAC CONTROLS
MP111 HVAC PIPING PLAN - BLDG 43 - FIRST FLOOR
MP112 HVAC PIPING PLAN - BLDG 43 - SECOND FLOOR
MP113 HVAC PIPING PLAN - BLDG 43 - THIRD FLOOR
MP114 HVAC PIPING PLAN - BLDG 43 - PENTHOUSE
MP121 HVAC PIPING PLAN - BLDG - 47 - FIRST FLOOR
MP122 HVAC PIPING PLAN - BLDG 47 - SECOND FLOOR
MP123 HVAC PIPING PLAN - BLDG 47 - THIRD FLOOR
MP124 HVAC PIPING PLAN - BLDG 47 - PENTHOUSE
ELECTRICAL
E-001 ELECTRICAL SYMBOL LEGEND
E-002 ELECTRICAL GENERAL NOTES AND ABBREVIATIONS
E-003 ELECTRICAL UTILITIES SEQUENCING
E-004 ELECTRICAL RISER DIAGRAMS & SCHEDULES - BLDG 48
ES101 ELECTRICAL SITE PLAN - UTILTIES
ES102 ELECTRICAL SITE LIGHTING PLAN
PLUMBING
P-001 PLUMBING ABBREVIATIONS, SYMBOLS, GENERAL NOTES
PD111 BLDG 43 - PLUMBING DEMO - FIRST FLOOR
PD112 BLDG 43 - PLUMBING DEMO - SECOND FLOOR
PD113 BLDG 43 - PLUMBING DEMO - THIRD FLOOR
PD114 BLDG 43 - PLUMBING DEMO - PENTHOUSE
PD120 BLDG 47 - PLUMBING DEMO - BASEMENT FLOOR
PD121 BLDG 47 - PLUMBING DEMO - FIRST FLOOR
PD122 BLDG 47 - PLUMBING DEMO - SECOND FLOOR
PD123 BLDG 47 - PLUMBING DEMO - THIRD FLOOR
PD124 BLDG 47 - PLUMBING DEMO - PENTHOUSE
PP111 BLDG 43 - PLUMBING PLAN - FIRST FLOOR - WATER PIPING
PP112 BLDG 43 - PLUMBING PLAN - SECOND FLOOR - WATER PIPING
PP113 BLDG 43 - PLUMBING PLAN - THIRD FLOOR - WATER PIPING
PP114 BLDG 43 - PLUMBING PLAN - PENTHOUSE - WATER PIPING
PP115 BLDG 43 - PLUMBING PLAN - FOUNDATION - SANITARY/STORM SEWER
PP116 BLDG 43 - PLUMBING PLAN - FIRST FLOOR - SANITARY/STORM SEWER
PP117 BLDG 43 - PLUMBING PLAN - SECOND FLOOR - SANITARY/STORM SEWER
PP118 BLDG 43 - PLUMBING PLAN - THIRD FLOOR - SANITARY/STORM SEWER
PP119 BLDG 43 - PLUMBING PLAN - PENTHOUSE - SANITARY/STORM SEWER
PP120 BLDG 47 - PLUMBING PLAN - FOUNDATION - SANITARY/STORM SEWER
PP121 BLDG 47 - PLUMBING PLAN - BASEMENT FLOOR - WATER PIPING
PP122 BLDG 47 - PLUMBING PLAN - FIRST FLOOR - WATER PIPING
PP123 BLDG 47 - PLUMBING PLAN - SECOND FLOOR - WATER PIPING
PP124 BLDG 47 - PLUMBING PLAN - THIRD FLOOR - WATER PIPING
PP125 BLDG 47 - PLUMBING PLAN - PENTHOUSE - WATER PIPING
PP126 BLDG 47 - PLUMBING PLAN - BASEMENT - SANITARY/STORM SEWER
PP127 BLDG 47 - PLUMBING PLAN - FIRST FLOOR - SANITARY/STORM SEWER
PP128 BLDG 47 - PLUMBING PLAN - SECOND FLOOR - SANITARY/STORM SEWER
PP129 BLDG 47 - PLUMBING PLAN - THIRD FLOOR - SANITARY/STORM SEWER
PP130 BLDG 47 - PLUMBING PLAN - SANITARY/STORM SEWER - PENTHOUSE
PP131 BLDG 47 - PLUMBING PLAN - SANITARY/STORM SEWER - PENTHOUSE ROOF
PP213 BLDG 43 - MEDICAL GAS PLAN - THIRD FLOOR
PP214 BLDG 43 - MEDICAL GAS PLAN - PENTHOUSE
AE521 ROOF DETAILS
AE522 ROOF DETAILS
AE531 DOOR DETAILS
AE532 DOOR DETAILS
AE533 DOOR DETAILS
AE534 DOOR DETAILS
AE541 EXPANSION JOINT DETAILS
AE542 EXPANSION JOINT DETAILS
AE543 EXPANSION JOINT DETAILS
AE551 PARTITION TYPES
AE560 CASEWORK DETAILS
AE561 CASEWORK DETAILS
AE562 MILLWORK DETAILS
AE571 MISCELLANEOUS DETAILS
AE601 ROOM SCHEDULE
AE602 ROOM FINISH SCHEDULE
AE603 DOOR SCHEDULE
AE604 WINDOW AND LOUVER TYPES AND DETAILS
INTERIOR
IF111 BLDG 43 - INTERIOR FINISHES - FIRST FLOOR
IF112 BLDG 43 - INTERIOR FINISHES - SECOND FLOOR
IF113 BLDG 43 - INTERIOR FINISHES - THIRD FLOOR
IF120 BLDG 47 - INTERIOR FINISHES - BASEMENT
IF121 BLDG 47 - INTERIOR FINISHES - FIRST FLOOR
IF122 BLDG 47 - INTERIOR FINISHES - SECOND FLOOR
IF123 BLDG 47 - INTERIOR FINISHES - THIRD FLOOR
IN111 BLDG 43 - FURNITURE PLAN - FIRST FLOOR
IN112 BLDG 43 - FURNITURE PLAN - SECOND FLOOR
IN121 BLDG 47 - FURNITURE PLAN - FIRST FLOOR
IN122 BLDG 47 - FURNITURE PLAN - SECOND FLOOR
IN123 BLDG 47 - FURNITURE PLAN - THIRD FLOOR
IN125 FURNITURE SCHEDULE
IN126 SIGNAGE SCHEDULE
IN127 SIGNAGE DETAILS
IN427 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
IN428 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
IN429 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
IN430 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
FIRE PROTECTION
FA101 FIRE ALARM ZONING PLAN
FA102 FIRE ALARM DEMOLITION PLAN
FA103 SMOKE CONTROL ZONING PLAN
FA110 BLDG 43 - FIRE ALARM PLAN - BASEMENT
FA111 BLDG 43 - FIRE ALARM PLAN - FIRST FLOOR
FA112 BLDG 43 - FIRE ALARM PLAN - SECOND FLOOR
FA113 BLDG 43 - FIRE ALARM PLAN - THIRD FLOOR
FA114 BLDG 43 - FIRE ALARM PLAN - PENTHOUSE
FA120 BLDG 47 - FIRE ALARM PLAN - BASEMENT
FA121 BLDG 47 - FIRE ALARM PLAN - FIRST FLOOR
FA122 BLDG 47 - FIRE ALARM PLAN - SECOND FLOOR
FA123 BLDG 47 - FIRE ALARM PLAN - THIRD FLOOR
FA124 BLDG 47 - FIRE ALARM PLAN - PENTHOUSE
FA601 FIRE ALARM RISER DIAGRAM
FX101 FIRE SUPPRESSION ZONING PLAN
FX102 FIRE SUPPRESSION DEMOLITION PLAN
FX110 BLDG 43 - FIRE SUPPRESSION PLAN - BASEMENT
FX111 BLDG 43 - FIRE SUPPRESSION PLAN - FIRST FLOOR
FX112 BLDG 43 - FIRE SUPPRESSION PLAN - SECOND FLOOR
FX113 BLDG 43 - FIRE SUPPRESSION PLAN - THIRD FLOOR
FX114 BLDG 43 - FIRE SUPPRESSION PLAN - PENTHOUSE
FX120 BLDG 47 - FIRE SUPPRESSION PLAN - BASEMENT
FX121 BLDG 47 - FIRE SUPPRESSION PLAN - FIRST FLOOR
FX122 BLDG 47 - FIRE SUPPRESSION PLAN - SECOND FLOOR
FX123 BLDG 47 - FIRE SUPPRESSION PLAN - THIRD FLOOR
FX124 BLDG 47 - FIRE SUPPRESSION PLAN - PENTHOUSE
FX601 FIRE SUPPRESSION DETAILS
ARCHITECTURAL
AS101 AT/FP SITE PLAN
AD111 BLDG 43 - DEMOLITION PLAN - FIRST FLOOR
AD112 BLDG 43 - DEMOLITION PLAN - SECOND FLOOR
AD113 BLDG 43 - DEMOLITION PLAN - THIRD FLOOR
AD114 BLDG 43 - DEMOLITION PLAN - PENTHOUSE
AD115 BLDG 43 - DEMOLITION PLAN - PENTHOUSE ROOF
AD120 BLDG 47 - DEMOLITION PLAN - BASEMENT
AD121 BLDG 47 - DEMOLITION PLAN - FIRST FLOOR
AD122 BLDG 47 - DEMOLITION PLAN - SECOND FLOOR
AD123 BLDG 47 - DEMOLITION PLAN - THIRD FLOOR
AD124 BLDG 47 - DEMOLITION PLAN - PENTHOUSE
AD125 BLDG 47 - DEMOLITION PLAN - PENTHOUSE ROOF
AE100 COMPOSITE FLOOR PLAN - BASEMENT
AE101 COMPOSITE FLOOR PLAN - FIRST FLOOR
AE102 COMPOSITE FLOOR PLAN - SECOND FLOOR
AE103 COMPOSITE FLOOR PLAN - THIRD FLOOR
AE104 COMPOSITE FLOOR PLAN - PENTHOUSE
AE105 COMPOSITE FLOOR PLAN - ROOF
AE111 BLDG 43 - FLOOR PLAN - FIRST FLOOR
AE112 BLDG 43 - FLOOR PLAN - SECOND FLOOR
AE113 BLDG 43 - FLOOR PLAN - THIRD FLOOR
AE114 BLDG 43 - FLOOR PLAN - PENTHOUSE
AE115 BLDG 43 - FLOOR PLAN - ROOF
AE120 BLDG 47 - FLOOR PLAN - BASEMENT
AE121 BLDG 47 - FLOOR PLAN - FIRST FLOOR
AE122 BLDG 47 - FLOOR PLAN - SECOND FLOOR
AE123 BLDG 47 - FLOOR PLAN - THIRD FLOOR
AE124 BLDG 47 - FLOOR PLAN - PENTHOUSE
AE125 BLDG 47 - FLOOR PLAN - ROOF
AE131 BLDG 43 - REFLECTED CEILING PLAN - FIRST FLOOR
AE132 BLDG 43 - REFLECTED CEILING PLAN - SECOND FLOOR
AE133 BLDG 43 - REFLECTED CEILING PLAN - THIRD FLOOR
AE134 BLDG 43 - REFLECTED CEILING PLAN - PENTHOUSE
AE140 BLDG 47 - REFLECTED CEILING PLAN - BASEMENT
AE141 BLDG 47 - REFLECTED CEILING PLAN - FIRST FLOOR
AE142 BLDG 47 - REFLECTED CEILING PLAN - SECOND FLOOR
AE143 BLDG 47 - REFLECTED CEILING PLAN - THIRD FLOOR
AE144 BLDG 47 - REFLECTED CEILING PLAN - PENTHOUSE
AE151 COMPOSITE AIR BARRIER FLOOR PLAN - FIRST FLOOR
AE201 BLDG 43 - EXTERIOR ELEVATIONS
AE202 BLDG 43 - EXTERIOR ELEVATIONS
AE203 BLDG 43 - EXTERIOR ELEVATIONS
AE204 BLDG 47 - EXTERIOR ELEVATIONS
AE205 BLDG 47 - EXTERIOR ELEVATIONS
AE206 BLDG 47 - EXTERIOR ELEVATIONS
AE207 BLDG 47 - EXTERIOR ELEVATIONS
AE208 BLDG 47/43 - EXTERIOR ELEVATIONS
AE301 BLDG 43 - BUILDING SECTIONS
AE302 BLDG 43 - BUILDING SECTIONS
AE303 BLDG 47 - BUILDING SECTIONS
AE304 BLDG 47 - BUILDING SECTIONS
AE305 BLDG 47 - BUILDING SECTIONS
AE306 BLDG 47 - BUILDING SECTIONS
AE307 BLDG 47 - BUILDING SECTIONS
AE308 BLDG 47 - BUILDING SECTIONS
AE311 BLDG 43 - WALL SECTIONS
AE312 BLDG 43 - WALL SECTIONS
AE313 BLDG 43 - WALL SECTIONS
AE314 BLDG 43 - WALL SECTIONS
AE315 BLDG 43/47 - WALL SECTIONS
AE316 BLDG 47 - WALL SECTIONS
AE317 BLDG 47 - WALL SECTIONS
AE318 BLDG 47 - WALL SECTIONS
AE319 BLDG 47 - WALL SECTIONS
AE320 BLDG 47 - WALL SECTIONS
AE401 STANDARD MOUNTING HEIGHT
AE402 BLDG 43 - ENLARGED RESTROOM PLANS & INTERIOR ELEVATIONS
AE403 BLDG 47 - ENLARGED RESTROOM PLANS & INTERIOR ELEVATIONS
AE404 BLDG 43 - ENLARGED STAIR PLANS AND SECTIONS
AE406 BLDG 47 - ENLARGED STAIR AND ELEVATOR PLANS
AE407 BLDG 47 - ENLARGED STAIR AND ELEVATOR PLANS AND SECTIONS
AE408 BLDG 47 - ENLARGED STAIR PLANS AND SECTIONS
AE409 BLDG 47 - ENLARGED ELEVATOR/RAMP PLANS AND SECTION
AE410 BLDG 43/47 - STAIR DETAILS
AE421 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE422 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE423 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE424 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE425 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE426 BLDG 43 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE431 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE432 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE433 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE434 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE435 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE436 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE437 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE438 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE439 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE440 BLDG 47 - ENLARGED PLANS & INTERIOR ELEVATIONS
AE441 BLDG 43 - ENLARGED REFLECTED CEILING PLANS
AE442 BLDG 47 - ENLARGED REFLECTED CEILING PLANS
AE501 PLAN DETAILS
AE502 PLAN DETAILS
AE503 PLAN DETAILS
AE504 PLAN DETAILS
AE505 PLAN DETAILS
AE506 PLAN DETAILS
AE507 PLAN DETAILS
AE508 PLAN DETAILS
AE509 PLAN DETAILS
AE511 SECTION DETAILS
AE512 SECTION DETAILS
AE513 SECTION DETAILS
AE514 SECTION DETAILS
AE515 SECTION DETAILS
AE516 SECTION DETAILS
GENERAL
GI001A COVER SHEET - VOLUME 1 of 3
GI001B COVER SHEET - VOLUME 2 of 3
GI001C COVER SHEET - VOLUME 3 of 3
GI002 SHEET INDEX
GI003 LEGEND AND ABBREVIATIONS
GI004 LOCATION MAP
GI005 FIRE PROTECTION LIFE SAFETY SITE PLAN
GI006 BUILDING CODE ANALAYSIS AND GENERAL NOTES
GI007 PHASING PLANS
GI100 COMPOSITE LIFE SAFETY PLAN - BASEMENT
GI101 COMPOSITE LIFE SAFETY PLAN - FIRST FLOOR
GI102 COMPOSITE LIFE SAFETY PLAN - SECOND FLOOR
GI103 COMPOSITE LIFE SAFETY PLAN - THIRD FLOOR
GI104 COMPOSITE LIFE SAFETY PLAN - PENTHOUSE
GI110 BLDG 43 - LIFE SAFETY PLAN - BASEMENT
GI111 BLDG 43 - LIFE SAFETY PLAN - FIRST FLOOR
GI112 BLDG 43 - LIFE SAFETY PLAN - SECOND FLOOR
GI113 BLDG 43 - LIFE SAFETY PLAN - THIRD FLOOR
GI114 BLDG 43 - LIFE SAFETY PLAN - PENTHOUSE
GI120 BLDG 47 - LIFE SAFETY PLAN - BASEMENT
GI121 BLDG 47 - LIFE SAFETY PLAN - FIRST FLOOR
GI122 BLDG 47 - LIFE SAFETY PLAN - SECOND FLOOR
GI123 BLDG 47 - LIFE SAFETY PLAN - THIRD FLOOR
GI124 BLDG 47 - LIFE SAFETY PLAN - PENTHOUSE
CIVIL
CA001 CIVIL NOTES
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CG101 GRADING PLAN
CG201 EROSION CONTROL PLAN
CU101 UTILITY PLAN
CK501 DETAILS
CK502 CIVIL DETAILS
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-002 STRUCTURAL GENERAL NOTES
S-003 STRUCTURAL GENERAL NOTES
S-004 STRUCTURAL GENERAL NOTES
SD101 BLDG 43 - FIRST FLOOR DEMOLITION PLAN
SD102 BLDG 43 - SECOND FLOOR FRAMING DEMOLITION PLAN
SD103 BLDG 43 - THIRD FLOOR FRAMING DEMOLITION PLAN
SD104 BLDG 43 - THIRD FLOOR ROOF FRAMING DEMOLITION PLAN
SD105 BLDG 43 - PENTHOUSE FLOOR FRAMING DEMOLITION PLAN
SD106 BLDG 43 - PENTHOUSE ROOF FRAMING DEMOLITION PLAN
SD110 BLDG 47 - BASEMENT/ FOUNDATION DEMOLITION PLAN
SD111 BLDG 47 - FIRST FLOOR DEMOLITION PLAN
SD112 BLDG 47 - SECOND FLOOR PARTIAL FRAMING DEMOLITION PLAN
SD113 BLDG 47 - THIRD FLOOR PARTIAL FRAMING DEMOLITION PLAN
SD114 BLDG 47 - ROOF / PENTHOUSE FLOOR PARTIAL FRAMING DEMOLITION PLAN
SD115 BLDG 47 - PENTHOUSE MEZZANINE PARTIAL FRAMING DEMOLITION PLAN
SD116 BLDG 47 - PENTHOUSE ROOF FRAMING DEMOLITION PLAN
SD301 BLDG 43 - DEMOLITION BUILDING SECTIONS
SB100 BLDG 43 - FOUNDATION PLAN
SB110 BLDG 47 - FOUNDATION PLAN
SB501 FOUNDATION DETAILS
SB502 FOUNDATION DETAILS
SB503 FOUNDATION DETAILS
SB504 FOUNDATION DETAILS
SB505 FOUNDATION DETAILS
SF101 BLDG 43 - FIRST FLOOR / FOUNDATION PLAN
SF102 BLDG 43 - SECOND FLOOR FRAMING PLAN
SF103 BLDG 43 - THIRD FLOOR FRAMING PLAN
SF104 BLDG 43 - THIRD FLOOR ROOF FRAMING PLAN
SF105 BLDG 43 - PENTHOUSE FLOOR FRAMING PLAN
SF106 BLDG 43 - PENTHOUSE ROOF FRAMING PLAN
SF111 BLDG 47 - FIRST FLOOR FRAMING PLAN
SF112 BLDG 47 - SECOND FLOOR FRAMING PLAN
SF113 BLDG 47 - THIRD FLOOR FRAMING PLAN
SF114 BLDG 47 - ROOF / PENTHOUSE FLOOR FRAMING PLAN
SF115 BLDG 47 - PENTHOUSE ROOF FRAMING PLAN
SF116 ELEVATOR / STAIR TOWER TYPICAL REINFORCING AND MACHINE ROOM AND ROOF
FRAMING PLAN
SF122 BLDG 43 - SECOND FLOOR FRP STRENGTHENING PLAN
SF123 BLDG 43 - THIRD FLOOR FRP STRENGTHENING PLAN
SF132 BLDG 47 - SECOND FLOOR FRP STRENGTHENING PLAN
SF133 BLDG 47 - THIRD FLOOR FRP STRENGTHENING PLAN
SF134 BLDG 47 - ROOF / PENTHOUSE FLOOR FRP STRENGTHENING PLAN
SF135 BLDG 47 - PARTIAL FRP STRENGTHENING PLAN FOR ENLARGING SECOND FLOOR EXISTING
OPENING
SF136 BLDG 47 - PARTIAL FRP STRENGTHENING PLAN FOR ENLARGING THIRD FLOOR EXISTING
OPENING
SF137 PARTIAL FRP STRENGTHENING PLANS
SF501 COLUMN ENCASEMENT DETAILS
SF502 NEW COLUMN DETAILS
SF511 CMU WALL DETAILS
SF512 CMU AND CONCRETE WALL DETAILS
SF513 ELEVATOR / STAIR TOWER SECTIONS
SF514 ELEVATOR / STAIR TOWER SECTIONS
SF515 CMU AND CONCRETE WALL DETAILS
SF521 BEAM DETAILS
SF522 BEAM DETAILS
SF523 BEAM AND PLATFORM DETAILS
SF531 FRP STRENGTHENING DETAILS
SF541 AT / FP DETAILS
SF542 AT / FP DETAILS
SF543 AT / FP DETAILS
SF551 STAIR AND ELEVATOR DETAILS
SF561 MISCELLANEOUS DETAILS
SF571 EQUIPMENT HANGER DETAILS
SF581 STRUCTURAL REPAIR DETAILS
SF601 COLUMN SCHEDULES
SF611 BEAM SCHEDULES
SF641 BLDG 43 - LIVE LOAD DIAGRAM PLANS
SF642 BLDG 43 - LIVE LOAD DIAGRAM PLANS
SF643 BLDG 47 - LIVE LOAD DIAGRAM PLANS
SF644 BLDG 47 - LIVE LOAD DIAGRAM PLANS
VOLUME 1 of 3 VOLUME 2 of 3
VOLUME 3 of 3
GENERAL SYMBOLSSECTION SYMBOLS
MATERIAL INDICATIONS
STANDARD ABBREVIATIONS
GENERAL NOTES
EARTH
CONCRETE
GRAVEL
BRICK
METAL
PLYWOOD
WOOD (FINISH)
WOOD (ROUGH)
CRUSHED ROCK
PLASTER
GLASS (ELEVATION)
BLANKET INSULATION
RIGID INSULATION
GYPSUM WALLBOARD
CONCRETE MASONRY UNITS
MARBLE
STONE (ELEVATION)
STONE (SECTION)
WOOD (SURFACE)
WALL SECTION SYMBOL
FULL BUILDING SECTION SYMBOL
EXTERIOR ELEVATION SYMBOL
INTERIOR ELEVATION SYMBOL
A-XXX
X
SHEET NUMBER WHERE ELEVATION IS
SHOWN *
SHEET NUMBER WHERE ELEVATION IS
SHOWN *
DIRECTION OF SIGHT OF ELEVATION ON
PLAN
SHEET NUMBER WHERE ELEVATION IS
SHOWN
DIRECTION OF SIGHT OF ELEVATION ON
PLAN
DIRECTION OF SIGHT OF ELEVATION ON PLAN
A-XXX
X
A-XXX
X
A-XXX
X
DETAIL SECTION SYMBOL
SHEET NUMBER WHERE ELEVATION IS
SHOWN *
DIRECTION OF SIGHT OF ELEVATION ON
PLAN
A-XXX
X
A-XXX
DIRECTION OF SIGHT OF ELEVATION ON
PLAN
SHEET NUMBER WHERE ELEVATION IS
SHOWN
ROOM NAME AND NUMBER
DOOR NUMBERS
COLUMN LINES NUMBER-LETTER
(OPPOSITE DIR.)
MATCH LINE INDICATOR
WINDOW TYPES
CENTER LINE
DIRECTION OF PHOTOGRAPH
VIEW
WALL AND PARTITION TYPES
KEYNOTE INDICATOR
REVISION SYMBOL
DETAIL INDICATOR
CENTERLINE INDICATOR
LOUVER TYPES
ELEVATION INDICATOR
SLOPE ARROW
SCALE BAR
STANDARD NORTH ARROW
DRAWING TITLE BAR
150 SF
ROOM NAME
CODE1
150 SF
A1
101 A
1t
1i
SEE XX-XXX
MACTH LINE
X
X
X-XXX
SIM
1t
NTRUE
NORTH
DRAWING TITLE
X
1/8" = 1'-0"
ROOM CODE
ACTUAL AREA
REQUIRED AREA
4'
SCALE : 1/8" = 1'-0"
0 8' 16'
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND ARE PERTINENT TO THE CONDITIONS
ON THIS SET OF DRAWINGS TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY APPEAR IN THIS SET OF DRAWINGS TO
INDICATE SPECIFIC CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
E S T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I N
T E
R I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
5 6 7 8 9
STAMP
7/27/2017 2:12:53 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI003
T en th
S tr ee t N
.E
S u it e
A tl an ta
G A
U
SA
T el
-8
-8
F ax
-8
-8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs ity S q
H u n ts v ill e A
L
L E
G E
N D
A N
D A
B B
R E
V
IA
T
IO
N S
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
V .P
A T
E L
L .W
R
IG
H T
L .W
R
IG
H T
J U
L Y
L .W
R
IG
H T
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TC TOP OF CURB
TEL TELEPHONE
TEMP TEMPERATURE
TERR TERRAZZO
TOC TOP OF CONCRETE
TOIL TOILET
TOPO TOPOGRAPHY
TOS TOP OF STEEL
TOW TOP OF WALL
TP TOP OF PAVEMENT
TRANS TRANSVERSE
TYP TYPICAL
UC UNDERCUT
UG UNDERGROUND
UH UNIT HEATER
UR URINAL
UV UNIT VENTILATOR
V VOLT
VB VINYL BASE
VC VERTICAL CURVE
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VFD VARIABLE FREQUENCY DRIVE
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W WATT
W/ WITH
W/O WITHOUT
WC WATER CLOSET OR WALL COVERING
WD WOOD
WDW WINDOW
WH WATER HEATER
WP WEATHERPROOF
WPFG WATERPROOFING
WS WATER STOP
WT WEIGHT
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
YD YARD
YH YARD HYDRANT
MET METAL
MFR MANUFACTURE
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MLO MAIN LUGS ONLY
MM MILLIMETER
MO MASONRY OPENING
MTG MOUNTING OR MOUNTED
MULL MULLION
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O/S OFFSET
OA OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE
OSS OVERFLOW STORM SEWER
OZ OUNCE
P PAINT OR PUMP OR PENDANT
PA PASCAL
PART PARTITION
PAVT PAVEMENT
PC POINT OF CURVATURE
PCF POUNDS PER CUBIC FOOT
PED PEDESTAL
PERP PERPENDICULAR
PHC PREHEAT COIL
PHVAC PLUMBING, HEATING, VENTILATING AND AIR
CONDITIONING
PI POINT OF INTERSECTION
PIV POST INDICATOR VALVE
PKG PARKING
PL PROPERTY LINE OR PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLF POUINDS PER LINEAR FOOT
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PR PAIR
PROJ PROJECTION
PRV PRESSURE REGULATING VALVE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTVC POINT OF VERTICAL CURVATURE
PVC POLYVINYL CHLORIDE
PVI POINT OF VERTICAL INTERSECTION
PVT POINT OF VERTICAL TANGENCY
QT QUARRY TILE
R RADIUS
RA RETURN AIR
RB RESILIENT BASE
RCP REINFORCED CONCRETE PIPE
RD ROOF DRAIN
REF REFERENCE
REFL REFLECTED
REG REGISTER
REINF REINFORCING
REQD REQUIRED
REV REVERSE
RF RETURN FAN
RGS RIGID GALVANIZED STEEL
RH ROOF HOOD
RHC REHEAT COIL
RM ROOM
RO ROUGH OPENING
ROW RIGHT OF WAY
S STAIR OR STAIN OR SURFACE
SA SUPPLY AIR OR SOUND ATTENUATOR
SAN SANITARY
SCH SCHEDULE
SECT SECTION
SF SQUARE FOOT
SHT SHEET
SIM SIMILAR
SK SINK
SOG SLAB-ON-GRADE
SP SUMP PUMP
SPEC SPECIFICATIONS
SQ SQUARE
SS SERVICE SINK
SSTL STAINLESS STEEL
STA STATION
STD STANDARD
STE STANDARD TAPERED END
STIFF STIFFENER
STIR STIRRUP
STL STEEL
STN STAIN
STOR STORAGE
STR STRUCTURAL
SUSP SUSPENDED
SVF SHEET VINYL FLOORING
SW SWITCH
SWGR SWITCHGEAR
SYM SYMMETRICAL
EXH EXHAUST
EXIST EXISTING
EXP EXPOSED
EXPN EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FARX FIRE ALARM RADIO TRANSCEIVER
FCU FAN COIL UNIT
FD FLOOR DRAIN OR FIRE DAMPER
FDN FOUNDATION
FDR FEEDER
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH
FIX FIXTURE
FL FLOOR
FLCO FLOOR CLEANOUT
FM FORCE MAIN
FP FIREPROOFING
FR FIRE RATED
FRP FIBERGLASS REINFORCED PLASTIC
FT FEET
FTG FOOTING
FVC FIRE VALE CABINET
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GEN GENERATOR
GFRC GLASS FIBER REINFORCED CONCRETE
GI GALVANIZED IRON
GL GLASS
GLB GLASS BLOCK
GP GLAZED PAINT
GPM GALLONS PER MINUTE
GR GRADE
GWB GYPSUM WALLBOARD
GYP GYPSUM
HB HOSE BIBB
HC HEATING COIL
HDCP HANDICAP (PED)
HDNR HARDENER
HDW HARDWARE
HDWD HARDWOOD
HK1E HOOK ONE END
HK2E HOOK TWO ENDS
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HORSEPOWER
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING/VENTILATING/AIR CONDITIONING
HZ HERTZ
IC INTERCOM
ID INSIDE DIAMETER
IE INVERT ELEVATION
IF INSIDE FACE
IN IN
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
KCJ KEYED CONSTRUCTION JOINT
KCMIL THOUSAND CIRCULAR MILS
KIT KITCHEN
KS KITCHEN SINK
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATTS
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
LGC LIQUID GLAZED EPOXY COATING
LIN LINEAR
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMU LIGHTWEIGHT MASONRY UNITS
LONG LONGITUDINAL
LT LIGHT
LT WT LIGHT WEIGHT
LTG LIGHTING
LVL LEVEL
M METER
M2 SQUARE METER
M3 CUBIC METER
MAINT MAINTENANCE
MAR MARBLE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MDO MEDIUM DENSITY OVERLAY
MECH MECHANICAL
A/C AIR CONDITIONING
AB ANCHOR BOLT
ABS ACRYLONITRILE-BUTADIENE-STYRENE
AC ALTERNATING CURRENT
ACP ASBESTOS CEMENT PIPE
AD AREA DRAIN
ADJ ADJACENT OR ADJUSTABLE
ADR ACCESS DOOR
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AL ALTERNATE
ALUM ALUMINUM
ANZ ANODIZED
APPROX APPROXIMATELY
APT APARTMENT
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ATB AIR TERMINAL BOX
ATC ACOUSTICAL TILE CEILING
AUX AUXILIARY
AVG AVERAGE
AZ AZIMUTH
BB BALLED AND BURLAPPED
BD BOARD
BL BUILDING LINE
BLDG BUILDING
BLKG BLOCKING
BM BENCH MARK OR BEAM
BR BARE ROOT
BRG BEARING
BTU BRITISH THERMAL UNIT
C CONDUIT
C/C CENTER TO CENTER
CAB CABINET
CB CIRCUIT BREAKER OR CATCH BASIN
CC COOLING COIL
CDU COVER ELEVATION
CEM CEMENT
CFM CUBIC FEET PER MINUTE
CFS CORNER GUARD
CH CHILLER
CI CURB INLET OR CAST IRON
CIP CAST IRON PIPE
CJ CONTROL JOINT
CKT CIRCUIT
CL CENTER LINE
CLG CEILING
CLO CLOSET
CLR CLEAR
CM CENTIMETER
CMH CUBIC METER PER HOUR
CMP CORRUGATED METAL PIPE
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEANOUT
COL COLUMN
COMB COMBINATION OR COMBINE
COMP COMPRESSIBLE
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS OR CONTINUATION
CONTR CONTRACTOR
CORR CORRIDOR
CP CEMENT PIPE
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CUH CABINET UNIT HEATER
CUYD CUBIC YARD
DBL DOUBLE
DCA DENTAL COMPRESSED AIR
DEPR DEPRESSED
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIP DUCTILE IRON PIPE
DISC DISCONNECT
DISP DISPENSER
DIST DISTRIBUTION
DK DECK
DL DEAD LOAD
DLV DENTAL VACUUM
DN DOWN
DO DITTO
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWL DOWEL
DWP DOMESTIC WATER PUMP
EA EACH
EF EACH FACE OR EXHUAST FAN
EIFS EXTERIOR INSULATION FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC (AL)
ELEV ELEVATOR
EMBED EMBEDMENT
EMD ESTIMATED MAXIMUM DEMAND
EMT ELECTRTICAL METAL TUBING
EQ EQUAL
EQUIP EQUIPMENT
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
PROJECT
SITE
STREET VIEW
CITY VIEW8901 WISCONSIN AVE., BETHESDA, MD 20889
N
N
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
E S T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I N
T E
R I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
5 6 7 8 9
STAMP
7/27/2017 2:12:54 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI004
T en th
S tr ee t N
.E
S u it e
A tl an ta
G A
U
SA
T el
-8
-8
F ax
-8
-8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs ity S q
H u n ts v ill e A
L
L O
C A
T
IO
N M
A P
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
V .P
A T
E L
L .W
R
IG
H T
L .W
R
IG
H T
J U
L Y
L .W
R
IG
H T
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
DN
W B
A A S H T O
(U S c
T ra n s o f t
S o l ut i o n s
I n c A l l r i g h t s r e s e r v e d
E E
E E
GRAVEL PAD
CONCRETE
CO
CO
CO
CB
A
BLDG 43/47
BLDG 42A
BLDG 42B
BLDG
42C
BLDG 46
BLDG 45
BLDG 42
30' - 0"
30' - 0"
IMAGINARY LOT LINE - SHOWN WITH
30 FT. FIRE SEPARATION DISTANCE
EXISTING AFRRI FIRE
ALARM CONTROL PANEL
NEW BLDG 43/47
COMBINATION FIRE ALARM
MASS NOTIFICATION SYSTEM
CONTROL PANEL
FIRE DEPARTMENT
CONNECTION
LOCAL OPERATING CONSOLE,
ANNUNCIATOR, AND FIRE
FIGHTERS' SMOKE CONTROL
STATION LOCATION
(BASEMENT LEVEL ELEVATOR
LOBBY)
BLDG 47 STAIR 1 CLASS I
COMBINATION
SPRINKLER STANDPIPE
BLDG 47 STAIR 2 CLASS I
STANDPIPE
BLDG 43 STAIR 1 CLASS I
STANDPIPE
FIRE HYDRANT
FIRE HYDRANT
8" NORTH WATER
LINE LEAD-IN POST
INDICATOR VALVE
8" SOUTH WATER
LINE LEAD-IN POST
INDICATOR VALVE
FIRE HYDRANT
FIRE HYDRANT
FIRE HYDRANT
FIRE HYDRANT
2-HOUR FIRE WALL
(BUILDING SEPARATION)
FIRE DEPARTMENT
ACCESS ROUTE
FIRE DEPARTMENT
ACCESS ROUTE
8"
6"
12"
6"
8"
8"
8"
6"
8"
DOMESTIC WATER LINE (FOR
REFERENCE) - SEE SITE
UTILITY PLANS FOR DETAILED
INFO
20' M
IN
20' M
IN
20' MIN.
20' MIN.
APPLICABLE CODES AND STANDARDS
UNITED FACILITIES CRITERIA, GENERAL BUILDING REQUIREMENTS (CHANGE 3, 1 AUGUST 2015)UFC 1-200-01
UNITED FACILITIES CRITERIA, FIRE PROTECTION ENGINEERING FOR FACILITIES (8 AUGUST 2016)UFC 3-600-01
UNITED FACILITIES CRITERIA, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS (CHANGE 1, JANUARY 2010)UFC 4-021-01
INTERNATIONAL BUILDING CODE (2015 EDITION)IBC
NATIONAL FIRE PROTECTION ASSOCIATION, FIRE CODE (2015 EDITION)NFPA 1
NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR PORTABLE FIRE EXTINGUISHERS (2013 EDITION)NFPA 10
NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS & THEIR APPURTENANCES (2016 EDITION)NFPA 24
NATIONAL FIRE PROTECTION ASSOCIATION, NATIONAL ELECTRICAL CODE (2014 EDITION)UFC 70
NATIONAL FIRE PROTECTION ASSOCIATION, NATIONAL FIRE ALARM & SIGNALING CODE (2016 EDITION)UFC 72
NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING & VENTILATING SYSTEMS (2015 EDITION)NFPA 90A
NATIONAL FIRE PROTECTION ASSOCIATION, LIFE SAFETY CODE (2015 EDITION)NFPA 101
UNITED FACILITIES CRITERIA, DESIGN: MILITARY MEDICAL FACILITIES (CHANGE 1, MAY 2016)UFC 4-510-01
STANDARD ON FIRE AND LIFE SAFETY IN ANIMAL HOUSING FACILITIES (2016 EDITION)NFPA 150
NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (2016 EDITION)NFPA 13
NATIONAL FIRE PROTECTION ASSOCIATION, STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS (2016 EDITION)NFPA 14
1. SITE FIRE PROTECTION FEATURES SHALL BE IN ACCORDANCE WITH UFC 3-600-01.
2. REFERENCE GI-SERIES SHEETS FOR BUILDING AND LIFE SAFETY CODE COMPLIANCE
PLANS.
3. REFERENCE FA-SERIES SHEETS FOR FIRE ALARM AND SMOKE CONTROL SYSTEM PLANS.
4. REFERENCE FX-SERIES SHEETS FOR FIRE SUPPRESSION SYSTEM PLANS.
SITE FIRE PROTECTION PLAN - GENERAL NOTES
NTRUE
NORTH
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
KEY PLAN
E S
T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I
N T
E R
I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
43E
5 6 7 8 9
43W
42A
42B42C
7/12/2017 11:43:26 AM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI005
T e n th
S tr e e t N
.E S u it e
A tl a n ta G
A
U S
A T e l
-8
-8
F a x
-8 -8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs it y S q
H u n ts v ill e A
L
F
IR
E P
R O
T E
C T
IO
N
L
IF
E S
A F
E T
Y S
IT
E
P L A
N
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
A .S
C H
IE
B
E R
A .S
C H
IE
B
E R
D .G
O L D
B E
R G
J U
L Y
A .S
C H
IE
B
E R
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
1" = 40'-0" A2
SITE FIRE PROTECTION PLAN
SCALE : 1" = 40'-0"
0 40' 80'20'
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING
ELEMENTS: TYPE II-B
RATING (HOURS)BUILDING ELEMENT
0PRIMARY STRUCTURAL FRAME
NOTE
#2
0 / 2BEARING WALLS: EXTERIOR #3
0BEARING WALLS: INTERIOR -
0 / 2NONBEARING WALLS: EXTERIOR
0NONBEARING WALLS: INTERIOR -
0 / 1FLOOR CONSTRUCTION #4 & #5
0ROOF CONSTRUCTION #4
NOTES:
1. FIRE-RESISTANCE RATINGS ARE BASED OFF OF IBC TABLES 601
AND 602. SEE LIFE SAFETY PLANS FOR LOCATIONS OF RATED
PARTITIONS FOR ACCOMMODATION OF LIFE SAFETY CODE
REQUIREMENTS.
2. PRIMARY STRUCTURAL FRAME CONSISTS OF MEMBERS HAVING
DIRECT CONNECTION TO OTHERS DESIGNED TO CARRY GRAVITY
LOADS. SEE ARCHITECTURAL AND STRUCTURAL SHEETS FOR
SPECIFIC APPLICATION OF EACH ASSEMBLY.
3. EXTERIOR WALL RATING REQUIREMENTS ARE BASED OFF OF FIRE
SEPARATION DISTANCE AND THE REQUIREMENTS OF IBC TABLE 602.
THE EXISTING FACILITY ABUTS BUILDINGS 42 AND 45 AND ARE
PROVIDED WITH 2-HOUR FIRE WALLS AS A MEANS OF BUILDING
SEPARATION IN ACCORDANCE WITH IBC §706.
4. RATING REQUIREMENT FOR FLOOR AND ROOF CONSTRUCTION
INCLUDES SUPPORTING BEAMS AND JOISTS.
5. 1-HOUR FIRE-RESISTANT RATED FLOOR ASSEMBLIES ARE
PROVIDED IN CERTAIN AREAS TO PROVIDE THREE DIMENSIONAL
SEPARATION BETWEEN ANIMAL HOUSING AREAS AND HAZARDOUS
AREAS LOCATED ON ADJACENT STORIES.
#3
OCCUPANCY CLASSIFICATION (IBC)
Group B
Group S-2
BUILDING SEPARATION LEGEND
2-HOUR FIRE WALL
NTRUE
NORTH
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
KEY PLAN
E S
T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I
N T
E R
I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
43E
5 6 7 8 9
43W
42A
42B42C
7/12/2017 12:34:08 PM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI006
T e n th
S tr e e t N
.E S u it e
A tl a n ta G
A
U S
A T e l
-8
-8
F a x
-8 -8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs it y S q
H u n ts v ill e A
L
B U
IL
D
IN
G
C O
D E
A N
A L A
Y S
IS
A
N D
G E
N E
R A
L N
O T
E S
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
A .S
C H
IE
B
E R
A .S
C H
IE
B
E R
D .G
O L D
B E
R G
J U
L Y
A .S
C H
IE
B
E R
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
1" = 40'-0" F1
IBC OCCUPANCY CLASSIFICATION - BASEMENT
1" = 40'-0" C1
IBC OCCUPANCY CLASSIFICATION - FIRST FLOOR
OCCUPANCY CLASSIFICATION SCHEDULE
Occupancy Classification (IBC) Area
BASEMENT
MIXED, NONSEPARATED (GROUPS B & S-2)
Group B 1,064 SF
Group S-2 1,984 SF
3,049 SF
FIRST FLOOR
MIXED, NONSEPARATED (GROUPS B & S-2)
Group B 6,808 SF
Group S-2 11,392 SF
18,200 SF
SECOND FLOOR
MIXED, NONSEPARATED (GROUPS B & S-2)
Group B 3,445 SF
Group S-2 12,103 SF
15,548 SF
THIRD FLOOR
MIXED, NONSEPARATED (GROUPS B & S-2)
Group B 3,492 SF
Group S-2 9,401 SF
12,892 SF
PENTHOUSE
SINGLE OCCUPANCY (GROUP S-2)
Group S-2 9,128 SF
9,128 SF
58,817 SF
ALLOWABLE AREA ANALYSIS
Occupancy Classification Most
Restrictive
Building Construction
Type Full Sprinkler Protection?
Allowable Area - IBC
Allowable Area - NFPA
150 Actual Area
BASEMENT
Group B II-B Yes 69,000 SF NA 3,049 SF
FIRST FLOOR
Group B II-B Yes 69,000 SF 46,000 SF 18,200 SF
SECOND FLOOR
Group B II-B Yes 69,000 SF 46,000 SF 15,548 SF
THIRD FLOOR
Group B II-B Yes 69,000 SF 46,000 SF 12,892 SF
PENTHOUSE
Group S-2 II-B Yes 69,000 SF NA 9,128 SF
58,817 SF
1" = 40'-0" A1
IBC OCCUPANCY CLASSIFICATION - SECOND FLOOR
1" = 40'-0" F4
IBC OCCUPANCY CLASSIFICATION - THIRD FLOOR
1" = 40'-0" C4
IBC OCCUPANCY CLASSIFICATION - PENTHOUSE
1" = 40'-0" B4
IBC OCCUPANCY CLASSIFICATION - PENTHOUSE ROOF
SCALE : 1" = 40'-0"
0 40' 80'20'
UP
UP
DN
DN UP
UP
UPUP
BLDG 43 BLDG 47
EXISTING BAS OFFICE TO BE
RELOCATED TO NEWLY
RENOVATED SECOND FLOOR
BLDG 48
APPROXIMATE LOCATION OF
OVERHEAD WARM DRAIN TO
BE MAINTAINED DURING
CONSTRUCTION, VIF.
BLDG 45
TEMPORARY PARTITION
AND OR DOORS, 1 HR
RATED CONSTRUCTION
TEMPORARY PARTITION
TEMP PARTITION, 1HR
RATED CONSTRUCTION
MAINTAIN DELIVERY
ACCESS TO BLDG 48
BLDG 43 BLDG 47
BLDG 43 BLDG 47
43P04
BAS OFFICE
43P05
ELECTRICAL
ROOM
43P03
COMM
43P02
SECURITY
EQUIP
43P01
MECHANICAL
ROOM
MECH1
ROOMS SHOWN HATCHED TO BE
COMPLETED FIRST ALONG WITH ALL
RELATED ITEMS - COORDINATE WITH ALL
DICIPLINES.
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
KEY PLAN
E S T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I N
T E
R I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
43E
5 6 7 8 9
STAMP
43W
42A
42B42C
7/27/2017 2:12:59 PM C:\Users\ylu\Documents\Autodesk\Revit 2016 Projects\AFR-43-47_ARCH_ylu.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI007
T en th
S tr ee t N
.E
S u it e
A tl an ta
G A
U
SA
T el
-8
-8
F ax
-8
-8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs ity S q
H u n ts v ill e A
L
P H
A S
IN
G
P L A
N S
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
V .P
A T
E L
L .W
R
IG
H T
L .W
R
IG
H T
J U
L Y
L .W
R
IG
H T
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
3/64" = 1'-0"
PHASING PLAN - EXISTING FIRST FLOOR
D1
3/64" = 1'-0" D6
PHASING FLOOR PLAN - NEW SECOND FLOOR
1. EXISTING BUILDING 48 TO REMAIN OPERATIONAL DURING CONSTRUCTION,
REFER TO SHEET E-003 & E-004 FOR ELECTRICAL SEPARATION.
2. ALL WORK SHOWN ON SHEET E-003 & E-004 TO BE COMPLETED PRIOR TO
COMMENCEMENT OF WORK.
3. EXISTING BAS OFFICE TO BE RELOCATED TO SECOND FLOOR OF BUILDING 43
WEST.
4. EXISTING WARM DRAIN FROM BUILDING 45 TO REMAIN IN USE DURING
CONSTRUCTION, MARK AND PROTECT. CONTACT ON SITE RADIATION SAFETY FOR
PROCEDURE TO CONTAIN AND OR REPAIR ANY DAMAGED SECTIONS OF DRAIN.
5. PROVIDE TEMPORARY PARTITIONS TO SEPARATE BUILDINGS 48 AND 45.
NOTE:
CP-B.01 CP-B.01CP-B.01
C P
-B .0
C
P -B
.0
C P
-B .0
T D
-B .0
T
D -B
.0
T D
-B .0
T
D -B
.0
DOOR
2' - 8"
STAIR
3' - 0"
120 4
48BS1
DOOR
7' - 4"
47BS1
OCCUPANCY CLASSIFICATION (NFPA)
BUSINESS
INDUSTRIAL, SPECIAL-PURPOSE
COMPOSITE LIFE SAFETY NOTES:
SYMBOL
TRAVEL DISTANCE ROUTE
EGRESS PATH TYPES
TD-X.YY
COMMON PATH OF TRAVEL ROUTECP-X.YY
DEAD-END ROUTEDE-X.YY
NOTE: X = LEVEL
Y = SEQUENTIAL IDENTIFIER
A: EXIT COMPONENT TYPE (DOOR / STAIR)
EXIT COMPONENT TAGS
B: EXIT COMPONENT CLEAR WIDTH [FT-IN]
C: OCCUPANT LOAD CAPACITY [# OF PERSONS]
B
C D
A
E
D: EXPECTED OCCUPANT LOAD [# OF PERSONS]
E: EXIT COMPONENT ID
THE INTENT OF THESE PLANS IS TO SHOW OVERALL EGRESS CONFIGURATION FOR THE BUILDING AND
DEMONSTRATE COMPLIANCE WITH NFPA 101.
HATCHING ON THESE PLANS INDICATES OCCUPANCY CLASSIFICATION IN ACCORDANCE WITH NFPA 101.
GENERIC LINE TYPES FOR BUILDING SEPARATIONS AND OCCUPANCY SEPARATIONS ARE SHOWN ON THIS PLAN FOR AN OVERALL INDICATION OF OCCUPANCY CLASSIFICATION AND SEPARATION. REFER TO DETAILED LIFE
SAFETY PLANS FOR HOURLY RATING OF THESE BARRIERS.
REFER TO SUBSEQUENT ENLARGED LIFE SAFETY SHEETS SHOWING ENLARGED PLANS OF THE AREAS WITHIN THIS SCOPE OF WORK FOR LOCATIONS AND HOURLY RATINGS OF ALL BARRIERS TO BE PROVIDED AND APPLICATION OF
USE CATEGORIES FOR OCCUPANT LOAD CALCULATIONS.
A ZONED SMOKE CONTROL SYSTEM IS PROVIDED FOR THE FACILITY AS REQUIRED BY NFPA 150 SECTION 9.8.2. THE SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 92 AND SHALL MAINTAIN A MINIMUM PRESSURE DIFFERENCE OF 12.5 PA AND A MAXIMUM PRESSURE DIFFERENCE OF 75 PA ACROSS SMOKE CONTROL ZONE BOUNDARIES WHEN THE SYSTEM IS IN OPERATION. REFER TO FIRE ALARM AND HVAC SYSTEM PLANS FOR
ADDITIONAL INFORMATION.
LIFE SAFETY SYMBOLS:
DESCRIPTION
BUILDING SEPARATION
EXIT DISCHARGE
INTERIOR FINISH REQUIREMENTS BY OCCUPANCY
CLASSIFICATION
BUSINESS
FINISH OR INSULATION
MATERIAL
WALL AND CEILING FINISHES
A / BEXIT ENCLOSURES
A / BEXIT ACCESS CORRIDORS
A / B / CALL OTHER AREAS
FLOOR FINISHES
0 / 1
NOTES:
1. REFER TO ARCHITECTURAL SHEETS AND SPECIFICATIONS FOR FINISH MATERIALS AND RATINGS TO
BE USED.
2. IN ACCORDANCE WITH FOOTNOTE 6 TO NFPA TABLE A.10.2.2, DUE TO THE PRESENCE OF A
COMPLETE SPRINKLER SYSTEM, INTERIOR WALL AND CEILING FINISH WITH A FLAME SPREAD
RATING NOT EXCEEDING CLASS C IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS B IS REQUIRED, AND CLASS B INTERIOR WALL AND CEILING FINISH MATERIAL IS PERMITTED TO BE USED
IN ANY LOCATION WHERE CLASS A IS REQUIRED.
3. SIMILARLY, CLASS II INTERIOR FLOOR FINISH IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS I IS REQUIRED, AND NO INTERIOR FLOOR FINISH CLASSIFICATION IS REQUIRED WHERE CLASS
II IS REQUIRED.
CLASS I / IIEXIT ENCLOSURES
CLASS I / IIEXIT ACCESS CORRIDORS
NO CRITERIAALL OTHER AREAS
INSULATION MATERIALS
INDUSTRIAL,
SPECIAL-
PURPOSE
THERMAL/ACOUSTIC
INSULATION
A / B
A / B / C
A / B / C
0 / 1
CLASS I / II
CLASS I / II
NO CRITERIA
0 / 1
CLASS I / II
NO CRITERIA
A / B
A / B / C
A / B / C
ORDINARY
HAZARD
STORAGE
FLAME SPREAD RATING < 75
SMOKE DEVELOPED INDEX ≤ 150
NTRUE
NORTH
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
KEY PLAN
E S
T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I
N T
E R
I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
43E
5 6 7 8 9
43W
42A
42B42C
7/12/2017 11:43:44 AM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI100
T e n th
S tr e e t N
.E S u it e
A tl a n ta G
A
U S
A T e l
-8
-8
F a x
-8 -8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs it y S q
H u n ts v ill e A
L
C O
M P
O S
IT
E
L
IF
E S
A F
E T
Y P
L A
N
B A
S E
M E
N T
W
IS
C
O N
S
IN
A V
E B
E T
H E
S D
A M
D
A R
C H
IT
E
C T
U R
A L A
N D
E N
G
IN
E E
R
IN
G S
E R
V
IC
E S
A R
M E
D F
O R
C E
S R
A D
IO
B
IO
L O
G Y
R E
S E
A R
C H
IN
S
T
IT
U T
E
A F
R R
I) B
L D
G /4
D
E S
IG
N
A .S
C H
IE
B
E R
A .S
C H
IE
B
E R
D .G
O L D
B E
R G
J U
L Y
A .S
C H
IE
B
E R
X X
X X
X X
-X X
-X -X
X X
X
W D
Y -1
-D
-0
BLDG 43/47
1/16" = 1'-0" D1
COMPOSITE LIFE SAFETY PLAN - BASEMENT
MEANS OF EGRESS ARRANGEMENT - BASEMENT
Egress Path Name Occupancy Classification
Egress Path Length
Egress Path Maximum Permitted
CP-B.01 INDUSTRIAL, SPECIAL-PURPOSE 65' - 0" 100' - 0"
TD-B.01 BUSINESS 50' - 1" 300' - 0"
OCCUPANT LOAD CALCULATION - BASEMENT
Occupant Load Factor Use Category Area Occupant Load
Factor [SF/Person] Occupant
Load
MIXED, NONSEPARATED (GROUPS B & S-2)
Business Use - General 1,000 SF 100 10
Mechanical, Electrical, Other Building Equipment Spaces 2,049 SF 500 4
3,049 SF 14
EXIT CAPACITY COMPARISON - BASEMENT
Most Restrictive Egress Component Expected Occupant
LoadID Type Clear Width
Capacity Factor (in/Person)
Occupant Capacity
48BS1 Stair 3' - 0" 0.3 120 4
47BS1 Door 7' - 4" 0.2 440 10
560 14
8'
SCALE : 1/16" = 1'-0"
0 16' 32'
DN
CP-1.02CP-1.02
C P
-1 .0
C
P -1
.0
DOOR
5' - 4"
47413
DOOR
2' - 8"
E608
DOOR
2' - 8"
E609
DOOR
2' - 8"
47445
STAIR
4' - 0"
160 35
47S1
T D
-1 .0
T
D -1
.0
TD-1.01 TD-1.01TD-1.01
TD-1.01 TD-1.01TD-1.01 TD-1.01 TD-1.01
T D
-1 .0
T
D -1
.0
T D
-1 .0
T
D -1
.0
T D
-1 .0
T
D -1
.0
T D
-1 .0
TD-1.03TD-1.03
T D
-1 .0
T
D -1
.0
T D
-1 .0
TD-1.03 TD-1.03TD-1.03
TD-1.04TD-1.04
T D
-1 .0
T
D -1
.0
TD-1.04TD-1.04 TD-1.04TD-1.04TD-1.04
C P
-1 .0
1C P
-1 .0
TD-1.05TD-1.05
T D
-1 .0
T
D -1
.0
DOOR
2' - 8"
47453
DOOR
2' - 8"
431S1A
DOOR
2' - 8"
47454
OCCUPANCY CLASSIFICATION (NFPA)
BUSINESS
INDUSTRIAL, SPECIAL-PURPOSE
STORAGE, LOW & ORDINARY HAZARD
TO BUILDING 45
COMPOSITE LIFE SAFETY NOTES:
SYMBOL
TRAVEL DISTANCE ROUTE
EGRESS PATH TYPES
TD-X.YY
COMMON PATH OF TRAVEL ROUTECP-X.YY
DEAD-END ROUTEDE-X.YY
NOTE: X = LEVEL
Y = SEQUENTIAL IDENTIFIER
A: EXIT COMPONENT TYPE (DOOR / STAIR)
EXIT COMPONENT TAGS
B: EXIT COMPONENT CLEAR WIDTH [FT-IN]
C: OCCUPANT LOAD CAPACITY [# OF PERSONS]
B
C D
A
E
D: EXPECTED OCCUPANT LOAD [# OF PERSONS]
E: EXIT COMPONENT ID
THE INTENT OF THESE PLANS IS TO SHOW OVERALL EGRESS CONFIGURATION FOR THE BUILDING AND
DEMONSTRATE COMPLIANCE WITH NFPA 101.
HATCHING ON THESE PLANS INDICATES OCCUPANCY CLASSIFICATION IN ACCORDANCE WITH NFPA 101.
GENERIC LINE TYPES FOR BUILDING SEPARATIONS AND OCCUPANCY SEPARATIONS ARE SHOWN ON THIS PLAN FOR AN OVERALL INDICATION OF OCCUPANCY CLASSIFICATION AND SEPARATION. REFER TO DETAILED LIFE
SAFETY PLANS FOR HOURLY RATING OF THESE BARRIERS.
REFER TO SUBSEQUENT ENLARGED LIFE SAFETY SHEETS SHOWING ENLARGED PLANS OF THE AREAS WITHIN THIS SCOPE OF WORK FOR LOCATIONS AND HOURLY RATINGS OF ALL BARRIERS TO BE PROVIDED AND APPLICATION OF
USE CATEGORIES FOR OCCUPANT LOAD CALCULATIONS.
A ZONED SMOKE CONTROL SYSTEM IS PROVIDED FOR THE FACILITY AS REQUIRED BY NFPA 150 SECTION 9.8.2. THE SYSTEM SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 92 AND SHALL MAINTAIN A MINIMUM PRESSURE DIFFERENCE OF 12.5 PA AND A MAXIMUM PRESSURE DIFFERENCE OF 75 PA ACROSS SMOKE CONTROL ZONE BOUNDARIES WHEN THE SYSTEM IS IN OPERATION. REFER TO FIRE ALARM AND HVAC SYSTEM PLANS FOR
ADDITIONAL INFORMATION.
LIFE SAFETY SYMBOLS:
DESCRIPTION
BUILDING SEPARATION
EXIT DISCHARGE
INTERIOR FINISH REQUIREMENTS BY OCCUPANCY
CLASSIFICATION
BUSINESS
FINISH OR INSULATION
MATERIAL
WALL AND CEILING FINISHES
A / BEXIT ENCLOSURES
A / BEXIT ACCESS CORRIDORS
A / B / CALL OTHER AREAS
FLOOR FINISHES
0 / 1
NOTES:
1. REFER TO ARCHITECTURAL SHEETS AND SPECIFICATIONS FOR FINISH MATERIALS AND RATINGS TO
BE USED.
2. IN ACCORDANCE WITH FOOTNOTE 6 TO NFPA TABLE A.10.2.2, DUE TO THE PRESENCE OF A
COMPLETE SPRINKLER SYSTEM, INTERIOR WALL AND CEILING FINISH WITH A FLAME SPREAD
RATING NOT EXCEEDING CLASS C IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS B IS REQUIRED, AND CLASS B INTERIOR WALL AND CEILING FINISH MATERIAL IS PERMITTED TO BE USED
IN ANY LOCATION WHERE CLASS A IS REQUIRED.
3. SIMILARLY, CLASS II INTERIOR FLOOR FINISH IS PERMITTED TO BE USED IN ANY LOCATION WHERE CLASS I IS REQUIRED, AND NO INTERIOR FLOOR FINISH CLASSIFICATION IS REQUIRED WHERE CLASS
II IS REQUIRED.
CLASS I / IIEXIT ENCLOSURES
CLASS I / IIEXIT ACCESS CORRIDORS
NO CRITERIAALL OTHER AREAS
INSULATION MATERIALS
INDUSTRIAL,
SPECIAL-
PURPOSE
THERMAL/ACOUSTIC
INSULATION
A / B
A / B / C
A / B / C
0 / 1
CLASS I / II
CLASS I / II
NO CRITERIA
0 / 1
CLASS I / II
NO CRITERIA
A / B
A / B / C
A / B / C
ORDINARY
HAZARD
STORAGE
FLAME SPREAD RATING < 75
SMOKE DEVELOPED INDEX ≤ 150
NTRUE
NORTH
D A
T E
SHEET ID
IF SHEET MEASURES LESS THAN 22" X 34" IT IS A
REDUCED PRINT. REDUCE SCALE ACCORDINGLY
KEY PLAN
E S
T
P L
A N
N I N
G A
R C
H I T
E C
T U
R E
E N
G I N
E E
R I N
G I
N T
E R
I O
R S
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
IS
S
U E
D A
T E
C H
E C
K E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
X
M A
R K
D E
S C
R
IP
T
IO
N
A
B
C
D
E
F
G
1 2 3 4 10
US Army Corps of Engineers ®
43E
5 6 7 8 9
43W
42A
42B42C
7/12/2017 12:34:12 PM BIM 360://0005-013 AFRRI Bldg 43 & 47/AFR-43-47_FPLS.rvt
LAD Project No: 092-10061-009 ISSUED FOR CONSTRUCTION
GI101
T e n th
S tr e e t N
.E S u it e
A tl a n ta G
A
U S
A T e l
-8
-8
F a x
-8 -8
U .S
A rm y E n g in e e ri n g a n d
S u p p o rt
C e n te r H u n ts v ill e U n iv e rs it y S q
H u n ts v ill e A
L
C O
M P
O S
IT
E
L
IF
E S
A F
E T
Y P
L A
N
F
IR
S T
F L O
O R
W
IS
C
O…
This is the start of the file's text. The full file is on GovTribe.