Attachment 3 - Detroit_FloorPlan_Battery_Room.pdf

PDF 265 KB Posted

Attached to
Detroit Powerhouse Battery Bank Replacement
Solicitation number
W9127N24Q0091
Issued by

About this file

This document appears to be a floor plan for the Detroit Dam Powerhouse, which is relevant to the federal contract opportunity for the Detroit Powerhouse Battery Bank Replacement. The floor plan provides details on the layout and equipment within the powerhouse, including the battery room, switchgear, and other electrical systems.

The federal contract opportunity is solicitation W9127N24Q0091 issued by the Department of the Army Corps of Engineers Engineering District Portland. The requirement is for a stationary VRLA battery system, including certified seismic racks and spill control, as part of the 125VDC system at the Detroit Dam Powerhouse. No additional details on response dates, award dates, pricing, set asides, or incumbents are provided in the given information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPICAL LINE TYPES

(CO: 87, LT: HIDDEN, WT: 0)E-POWR-FEED - MECH. INTERLOCKS AND OTHER DASHED LINES

(CO: 4, LT: 0, WT: 1)E-ANNO-DIMS - DIMESIONING

(CO: 4, LT: 0, WT: 1)E-ANNO-TEXT - ALL OTHER TEXT

(CO: 7, LT: 0, WT: 2)E-POWR-CIRC - TYPICAL CIRCUIT LINES

(CO: 6, LT: 0, WT: 1)E-POWR-DEVC - ALL DEVICE OUTLINES

(CO: 1, LT: PHANTOM, WT: 2)E-POWR-PANEL - PANEL OUTLINES.

(CO: 87, LT: HIDDEN, WT: 2)E-POWR-URAC - CABLES

U P

A

SR

C O

N T

R A

C T

IO

N

J O

IN

T

DOWN

1 TIER

ROOM

HEAT PUMP

125 VOLT

BATTERY

UP

CQ6 PLC1 PLC0

P E

N S

T O

C K

R O

O M

B E

L O

W

EQUIP

COMMS

EQUIP

GDACS

DOWNDOWN

U P

DOWN

XJ2 XJ1

CLR1

XJ8XJ4XJ6XJ3XJ5XJ10XJ9

CLR2

VES

C Q

SB

CQ2

4 CABLE

TRAYS

4 CABLE

TRAYS

CPMPRESSOR

GOVERNOR AIR

SINK

TANK

PRESSURE

SUMP

OIL PUMPS

GOVERNOR

CE2

EL.1214.25

PLC2

JBAN

TANK

PRESSURE

SUMP

OIL PUMPS

GOVERNOR

BELOW CEALING

CABLE PULL BOX

EL.1213.0

PBD

CQ1

CE1

FM1

SX1

UNIT 1UNIT 2

U P

EQUIPMRNT

GROUNDING

NEUTRAL

CUBICAL

EXCITATION

PROTECTORS

P.T.'S & SURGE

CUBICAL

EXCITATION

PROTECTORS

P.T.'S & SURGE

SX2

C O

N T

R A

C T

IO

N

J O

IN

T

PED.

ROTOR

C O

T

A N

K S

C O

T

A N

K S

CO2 VALVES

CO2 CABINET "CY"

FM2

EL. 1225.0

ANN. HORN

CTC1

1 CABLE TRAY

DUCT BANK

C 13.8KV INSU. BUS

TELEPHONE CABINET EL.1224.0

CABLE VAULTS

CONTROL POWER

EL.1219.0 EL.1219.0

CABLE VAULTS

(TENTATIVE SIZE & LOCATION)

BREAKER TEST STATION XJT

JBT2

AT EL.1209

SOLENOID VALVE

EL.1205

CONTROL PANEL "DTA2"

DRAFT TUBE EVAC.

JBT1

EL.1205

CONTROL PANEL "DTA1"

DRAFT TUBE EVAC.

AT EL.1209

VALVE

SOLENOID

DOWN

G R H

G R H

480V. SWITCHGEAR "SQ" 480V. SWITCHGEAR "SQ"

C UNITS

TR2

ATS

TR1

FAR. VAL

EL.1209.0

SEPTIC TANK TOP

STORAGE

TR4JBB

TS

ROOM

ELECTRICAL EQUIPMENT

S B

S

B

INV BCE2 BCE1

EL.1218.5

FLOWMETER

WATER

GEN. COOL.

STA. 10+78.00

STA.11+42.00

STA.11+96.00

STA.12+54.00

26'-11 1/4 "58'-0" 27'- 3/4 " 26'-11 1/4 " 37'- 3/4 "

176'-0"

LIP-71P

LIT-71S

XMTRS

OIL LEVEL

LIP-71P

LIT-71S

XMTRS

OIL LEVEL

UP

A

LUB. OIL

LUB. OIL

TRANSIL OIL

TRANSIL OIL

D O

W N

STA. 11+96100

CQ4

TANK

SEPTIC

TANK

SEPTIC

COMPRESSORS

STATION AIR

CONTROL BOX

STATION AIR COMP.

PUMPS

UNWATERING

CO2 BOX

OIL PURIFIER

OIL PUMPS

AIR TANKS

LUB. OIL

CONTROL BOX

PUMP

OIL TRANSFER

MOISTURE DETECTOR

LAG SUMP PUMP

INS. OIL

CLEAN6

58'-0"

BORDER VERSION UPDATE [09-2012]

$SHEETN$SHEET NAME:$USER$BY USERNAME:DRAWING PLOT SIZE: $BORDER$ DATE AND TIME PLOTTED: $$$DATE$$$$ $TIME

DEP-10-6-9A40/2B

U .S

A

R M

Y E

N G

IN

E

E R

D

IS

T R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S

P O

R T

L A

N D

O

R E

G O

N

W

IL

L A

M E

T T

E R

IV

E

R B

A S

IN

,O

R E

G O

N

IDENTIFICATION

SHEET

SHEET OF

D A

T E

D

E S

IG

N

E D

B Y

D W

N B

Y

C K

D B

Y

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

S

U B

M

IT

T E

D B

Y

P L

O T

S C

A L

E P

L O

T D

A T

E

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

S I Z

E

A P

P R

D

A T

E D

E S

C R

IP

T

IO

N

M A

R K of Engineers

US Army Corps

654321

E

D

C

B

A

PORTLAND DISTRICT

N

5' 0 5' 10'

"= 1'-0"8

1SCALE:

NOTE:

5' 0 5' 10'

"= 1'-0"8

1SCALE:

PLAN - ASSEMBLY BAY - EL.1199.5

N O

R T

H S

A N

T

IA

M R

IV

E

R D

E T

R O

IT

D

A M

A N

D R

E S

E R

V O

IR

P O

W E

R H

O U

S E

E

L E

C T

R

IC

A L

/1

/2

S U

P E

R S

E D

E S

D E

P -9

-6 -9

A

/2

R

E V

IS

E

D P

E R

D G

U P

R O

J E

C T

C L

O S

E -O

U T

C O

N T

R D

W G

D E

P

.1

G -1

T V

T

P O

W E

R H

O U

S E

A R

R A

N G

E M

E N

TPLAN - EL.1213 & E.1214.25

SUPERSEDES DEP-9-6-9A40/2 REV 4

L A

K

W A

A

/1

/5

L A

K

REFERENCE DRAWINGS:

1. SEE DEP-10-6-9A40/2C FOR POWERHOUSE SECTION VIEW A-A.

P L

A N

E L

.1

E

L .1

.2

A

N D

P L

A N

A

S S

E M

B L

Y B

A Y

E L

.1 .5

POWERHOUSE ARRANGEMENT, SECTION VIEWS2. DEP-10-6-9A40/2C

PLAN E.1230 AND PLAN - GALLERY EL.1189.5

POWERHOUSE ARRANGEMENT1. DEP-10-6-9A40/2A

g2odvcpc Rectangle

File details come from the government source that posted it. Updated .