This document provides details for a federal contract solicitation for miter gate repair work at The Dalles Lock & Dam. The U.S. Army Corps of Engineers seeks bids for repairs between $1 million to $5 million. Bids are due September 20, 2021 and the primary points of contact are Charles Boswell and Kristina Morrow of the USACE-NWP Contracting Office. The solicitation is for repairing the miter gates at The Dalles Lock & Dam to restore functionality and water control. Interested vendors should direct inquiries to the points of contact by email, which is the preferred method for response, by the specified due date for consideration.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| C.04 - Abstract - 7N21B0024_s.pdf | ||
| B.08 - W9127N21B0024 0001.pdf | ||
| B.08 - W9127N21B0024.pdf | ||
| B.08 - Drawing Package ADVERTISE Portfolio.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
C
B
A
2.000" +0.000" -0.005"
I
I
I
I
1--------- 1 I I
I
I I r---------7 I I
I I
I I
DRILL AND TAP 3/8"-16 UNC-28
3/8" MIN. THREAD DEPTH
PLAN: ADJUSTMENT BOLT CLIP
MATERIAL: STAINLESS STEEL
PER: ASTM A 276. UNS S31600
NO. REQUIRED: 30
SCALE:NTS
Cl)
I I I I I I
" ., .,J 'i
I
I I
I I
I ---- I ___ _
I
Cl)
0.625" +0.005" -0.000"
CHAMFER 1/8" x 45°
<r.
I I
ED ELEVATION: ADJUSTMENT BOLT CLIP
- SCALE:NTS
CD SECTION: ADJUSTMENT BOLT CLIP
- SCALE:NTS
I _., I " \
I / I
I ---1---- 1 I l ' /
I ' I / /\ '- ,,, I ' ----- / ' / ' -
1" HEX BOLT
DIMENSIONS
PER ANSI 818.2.1
MATERIAL: STAINLESS STEEL
PER: ASTM F 593 ALLOY GROUP 5 UNS S41600
NO. REQUIRED: 30
8"
5¾5" THREADED LENGTH
THREAD 1" - 8 UNC-2A
t- -�- -�--�--
-i-- -1- -t- r-t- r-�- --�--t--
WEDGE ADJUSTMENT BOLT
SCALE: NTS
i31>
-t- i----- ------
1%2'' ½" w
• ro
0 Oaa .
·aa, +
Cl) a
CHAMFER 1/8" X 45°
GENERAL NOTES:
1. DIMENSIONAL TOLERANCES SHALL BE ±1/32" LINEAR AND 0.5'
ANGULAR, UNLESS OTHERWISE SHOWN.
2. BREAK ALL CORNERS AND EDGES.
3. 125 MICRON SURFACE TEXTURE ON ALL MACHINED
SURFACES,
EXCEPT AS NOTED. SURFACE TEXTURE PER ANSI 846.1.
4. SEE REFERENCE DRAWINGS DDN-1.104-3/29
AND DDN-1.104-3/24.
5. PROVIDE WEDGE BOLTS FOR REPLACEMENT OF EXISTING
BOLT ASSEMBLIES AT THE QUION DURING OPTIONAL QUOIN
ADJUSTMENT. SEE SHEET M-501 FOR GENERAL LAYOUT OF
WEDGE BOLTS. M-501 SHOWS THE MITER BLOCK ASSEMBLY BUT
THE QUOIN BLOCKS HAVE SIMILAR CONSTRUCTION.
US Army Corps of Engineers®
PORTLAND DISTRICT
0 0 0 0 0 w w w w w
Cl Cl Cl Cl
L
�G
LI
ci z ... ci z 81 QO z -al I-
� !;;:N �1-Z --"' �� Wo I-
,__ _,_ z
�� g?;
0 u
� uj uj c,Z a:
WUJ z a: ,, VJ uZ 0 i
WUJ VJ
:i:: z OD ►� .. :i: f-->-w al
ID f- .. 0 o □
□ - �"' w:;:w :i:
z:;: zi
1-wt: :i:
!:2� !@ ::, I= [fl<( gi <(
0::, 0--; VJ::,
(J) 0::
w w z f- z a u 0z il: (!) w f- w
u. !!l 0::
0 □ 0
(J) □ ci 0.. z z 0 :5 :5 u
Ii'.
f-
>- 0::
:i: 0 0 0:: 0.. 0..
N w
Cl al :::, z z
Cl
,ij
(L -w
VJ
9� "- -en ....I w Cl ::c en
....I
ID
0::
w I-
(L (L
0 w
UJ
Cl z ii:
u VJ w
C u.i � I
::, ,-.. <CS!
z.-, wz -'O ii: □ � w - N
VJ _z
VJ<(
SHEET
IDENTIFICATION
M-502