B.08_-_W9127N19B0024-0003_with_CLG-1.116_C-501_REVISION_17SEPT19.pdf
PDF 393 KB Posted
- Attached to
- Columbia River King Pile Navigation Aids
- Solicitation number
- W9127N19B0024
About this file
SF 30 with updated language and CLG-1.116_C-501_REVISION_17SEPT19
View the file
Other files
Show 40 more
Latest 50 of 65 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The purpose of this Amendment is:
To correct language in the 00 21 00 Submission Instructions.
To provide the updated draw ing: "CLG-1.116_C-501_REVISION_17SEPT19"
To provide a conformed copy of the Plans.
All other terms and conditions remain the same.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 17-Sep-2019
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9127N19B0024
X 9B. DATED (SEE ITEM 11)
22-Aug-2019
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
17-Sep-2019
CODE
USACE PORTLAND DISTRICT
333 SW 1ST AVE
PORTLAND OR 97204-3440
W9127N 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W9127N19B0024
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION 00 21 00 - INSTRUCTIONS
The following have been modified:
INSTRUCTIONS
SUBMISSION INSTRUCTIONS
INQUIRIES
(All inquiries regarding this solicitation are to be submitted via ProjNet-Bidsm. Telephone and email inquiries will not be accepted. ProjNet-Bidsm is a web-based program that allows bidders to post questions regarding the solicitation and to view all questions by other bidders and answers by USACE. ProjNet-Bidsm can be accessed through ProjNetsm at https://www.projnet.org/projnet/. To access the ProjNet-Bidsm website the first time:
1) Click the Bid tab
2) Click Bidder Inquiry. (The Agency is USACE.)
3) Enter the following information for access:
The Bidder Inquiry Key is: DADW68-FFQIZX
Valid business contact information (e.g. Company name, contact person, business address, phone number and email address). (required on first project only)
Establish secret question and answer which will be used as a password. (required on first project only)
4) For subsequent access use your email address, the Bid Inquiry Key and response to the secret question to access the ProjNet-Bidsm Module.
5) Submit questions or review questions and answers. (A bidder who submits a question will receive an automated email notification that their question has been received. When an answer is posted to a question, the question and answer is then available for all other bidders to review.
6) For a specific step-by-step for POSTING YOUR INQUIRIES, is available in the Reference link on the Contract Viewer.
7) For questions about the ProjNet-Bidsm, please contact the Call Center help desk toll free at 1-800-428- HELP, which operates from 8AM to 5PM (Central US time zone). ProjNet-Bidsm questions can also be emailed to the helpdesk at staff@rcesupport.com.
No response will be posted to inquiries after the Close of Business on the third business day preceding the solicitation due date. All bidders will be held to have reviewed the questions and responses in ProjNet-Bidsm prior to bid submission. Nothing in the solicitation is changed unless an amendment is sent out.
ELECTRONIC SUBMISSION INSTRUCTIONS
HARD COPY AND/OR EMAIL SUBMISSIONS WILL NOT BE CONSIDERED.
Bids are due no later than the time and date specified in Block 13 of Standard Form 1442, or SF 30 if applicable.
Bids received at the Government Point of Entry after the date and time in block 13.A of the solicitation will be considered a late bid, and will not be considered for award.
Offeror shall submit its Bid through the FedBizOpps (FBO.gov) system. The requirements and procedures for offer submission are found in the FBO Vendor User Guide located on the FBO webpage at:
https://www.fbo.gov/downloads/FBO_Vendor_Guide.pdf.
The electronic Bid shall be in Portable Document Format, filename extension: “.pdf” and suitable for viewing in Adobe Reader. Offerors shall bookmark and label each electronic PDF to afford easy identification from the Bid table of contents.
Offerors should enter a description for every file uploaded. For files over 10 megabytes (MB) the "Large Upload (JAVA)" button must be used. The combined file size limit for upload using "Large Upload (JAVA)" is 100MB. If needed, the offeror can break single files over 100MB into smaller files or use the upload utility multiple times if files exceed the 100MB size limit.
Once the offeror's Bid is submitted, it can be systematically revised prior to the solicitation response deadline. Refer to Paragraph 4.3.2 of the FBO Vendor Guide titled "Reviewing / Editing an Electric Response" for detailed guidance on completing a revision to an electronic Bid submission. Note: the FBO bid response system will send an email to the email address on file for the user confirming the electronic submission. Note: the offeror must be logged into the system to be able to submit / revise electronic responses.
For assistance and troubleshooting for the FBO electronic bid response system, contact the Federal Service Desk (FSD.gov). Phone: 866-606-8820 or Web Form (https://gsafsd.service-now.com/fsd-gov/login.do).
Do not assume submission will be instantaneous. File size and number of files to be uploaded will be factors to consider. Offeror/Teammate/Subcontractors should allow adequate time for submission completion because the entire Bid (i.e. offerors submission and all teammate/subcontractor(s) independent submissions) must be received by the time and date specified in Block 13 of Standard Form 1442, or SF 30 if applicable.
To avoid rejection of an offer, the offeror must make every effort to ensure its electronic submission is virus-free.
Bids, or portions thereof, submitted with the presence of a virus or which are otherwise unreadable will be treated as unreadable pursuant to FAR 15.207(c).
The requirement that an original and copy(ies) be submitted as found in block 13.A of the SF1442 is satisfied through the electronic submission. Additionally, electronic submission of the bid guarantee, when a bid guarantee is required, is due with the bid submission (mailing a bid guarantee is not allowed).
BID OPENING
No hard copy documents are allowed to be submitted at the bid opening. Due to the requirement that bids be submitted electronically only, bid opening is scheduled for one hour following the bid due date and time to allow the Contracting Office time to download all bid documents.
The bid opening will be held at 3:00 pm on the date bids are due in the bid room of the Block 300 Building, 333 SW First Avenue, Portland, Oregon.
NOTICE:
Due to increased security all individuals intending to attend the bid opening will need to clear security on the 10th floor prior to being allowed into the Block 300 bid room. Therefore, allow adequate time for arrival and security screening.
Individuals requesting access to Block 300 for the bid opening can expedite security processing by sending an email to the individual identified below. In the email subject line use title, “COLUMBIA KING PILE NAVIGATION
AIDS”.
It is required that the following information be included in the email.
FULL NAME
COMPANY
CITIZENSHIP
If more than one individual from one company is attending, then the above information is requested for each person attending.
Send your attendance email to: charles.m.boswell@usace.army.mil and/or ryan.s.shoemaker2@usace.army.mil.
If you do not receive an email confirmation that your information has been received then call 503-808-4609 and/or 503-808-4628.
NOTE: EMAIL SUBMISSIONS WILL NOT BE CONSIDERED.
(End of Summary of Changes)
G E
C D
J N
S F i l e
L a s t
S a v e d
B y
C-501
C O
L U
M B
I A
R
V
E R
K I N
G
P
I L
E
N A
V I G
A T
I O
N
A
I D
S
T Y
P I C
A L
D
E T
A I L S
M I C
H A
E L
S
C H
O C
H
P
E
J
S
E D
E Y
S T
O R
M Z
A N
D W
N
B
M A
T T
H E
W
D
H
A N
S O
N
P
E
A N
S I
D
C L
G
C d w g
R
E V
I S
I O
N
S E
P T
M P
S
PORTLAND DISTRICT
U S
A
R M
Y
C
O R
P S
F
E
N G
I N
E E
R S
P O
R T
L A
D
D
S
T R
I C
T S
O L I C
I T
A T
I O
N
N
O
F I L E
A M
E
D E
S I G
N E
D
B
Y
D E
S C
R I P
T I O
N M
A R
K
D A
T E
S I Z
E
S U
B M
I T
T E
D
B
Y
P L O
T
S
C A
L E
C O
N T
R A
C T
SHEET
IDENTIFICATION
D A
T E
A P
P R
D R
A W
I N
G
N
U M
B E
R
US Army Corps of Engineers
P L O
T
D
A T
E
54321
D
C
B
A
D R
A W
N
B
Y
C H
E C
K E
D
B
Y
DIKE
NOTES:
1. POSITION SIGN FRAME SO THAT SIGNS ARE ORIENTED PERPENDICULAR TO VESSEL TRAFFIC.
2. ATTACH SIGN FRAME TO PIPE PILE. DRILL
" Ø HOLES IN PIPE PILE AT 90°. DRILL AND TAP CORRESPONDING HOLE IN PILE CAP.
3. ATTACH PILE CAP TO PILE WITH (4)
" Ø X 4" LONG BOLTS w/ STANDARD SIZE WASHERS SPACED EQUAL DISTANCE AROUND
PERIMETER OF PILE. FIELD COAT BOLTS AFTER CAP IS INSTALLED.
4. COAT SIGN FRAME WITH SAME COATING AS PIPE PILES.
5. COAT ENTIRE LENGTH OF PILE.
6. POSITION HSS POST IN CENTER OF PILE CAP.
7. KTR TO ARRANGE SPIKES SO THAT NO MORE THAN 6" GAP BETWEEN SPIKES IS PRESENT.
8. GOVERNMENT WILL PERFORM QUALITY ASSURANCE SURVEY TO VERIFY THE SCOUR PROTECTION PLACEMENT AT ITS
DISCRETION.
3'-0"
3'-0"
" THICK STEEL PLATE,
DIAMETER PER TABLE
" THK. STEEL PLATE
(TYP. 3 LOCATIONS)
3NW REGULATORY SIGN,
BOTH SIDES, BOLTED TO FRAME
STD PIPE, PER TABLE
2" ORANGE
RETROREFLECTIVE
BORDER (R)
6" BLACK LETTERS
WHITE DAYBOARD FILM
PILE CAP TABLE
PILE
TYPE
PLATE
DIAMETER
(IN)
STD PIPE
SIZE (IN)
QTY
A 11 8 9
B 13 10 20
C 15 12 19
D 17 14 4
E 19 16 5
F 21 18 8
" Ø S.S. THROUGH BOLT,
w/ STANDARD SIZE WASHERS &
NUTS BOTH SIDES (4 TYP.)
S.S. BIRD SPIKES
ATTACH w/ S.S. SCREWS
BACKING RING
PIPE WALL TYP.
" Ø DRAIN HOLE, 4" FROM BASE
HSS 4x4x
" POST & ARMS
TYP. 2 LOCATIONS
TYP. 3 LOCATIONS
1'-6"
SCALE: NTS
TYPICAL KING PILE - PLAN VIEW
SCALE: NTS
TYPICAL KING PILE - SECTION
DEPTH OF PENETRATION
VAR. ≈ 22 to 35 FT
TOTAL STEEL PILE LENGTH
VAR. ≈ 50 to 80 FT
2'
8'
PILE CAP & REGULATORY SIGN
SEE DETAIL
C-501
SIGN FRAME
SCALE: 1-1/2" = 1'-0"
C-501
TOP OF PILE ELEVATION
VAR. ≈ 16 to 28 FT CRD
WATER SURFACE
ELEVATION
(VARIES)
SCOUR PROTECTION APRON
20 - 25 CY
EXISTING ENROCKMENT
(THICKNESS VARIES)
CONICAL SHOE
STEEL KING PILE
10" to 20" DIA.
MUDLINE/EXISTING
ENROCKMENT
ELEVATION
VAR. 0 to -34 FT CRD
1 (TYP)
STEEL KING PILE
10" to 20" DIA.
(LOCATION PER PLANS)
EXISTING TIMBER PILES
SIZE AND CONDITION VARIES
SCOUR PROTECTION APRON
20 - 25 CY
8'4' TYP
4"
5'
2'-6"
9"
2" - 3"
" Ø BOLT
S.S. BIRD SPIKES
ATTACH w/ S.S. SCREWS
S.S. BIRD SPIKES
ATTACH w/ S.S. SCREWS
4"
PIPE PILE
4"
SCALE: NTS
3NW REGULATORY SIGN
SCALE: NTS
PILE SPLICE DETAIL, TYP
" Ø DRAIN HOLE
(BOTTOM OF ARM)
FIELD SPLICE
MAY BE REQ'D,
TYP
STEEL KING PILE
10" to 20" DIA.
POINTED
CONICAL SHOE
TYPICAL CONICAL SHOE - DETAIL
SCALE: NTS
C-501
C-501
File details come from the government source that posted it.