AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04 EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
See SF30 Continuation Sheet(s)
NOTE: Proposal Receipt date is 16 August 2021, at 10:00 a.m.,CT, as previously announced.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 2
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA 15C. DATE SIGNED 15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer) (Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X 9A. AMENDMENT OF SOLICITATION NO.
W9126G21B0002
X 9B. DATED (SEE ITEM 11)
09-Jul-2021
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
3-Aug-2021
CODE
US ARMY ENGINEER DISTRICT, FORT WORTH
ATTN: CESWF-CT
819 TAYLOR ST, ROOM 2A19
P.O. BOX 17300
FORT WORTH TX 76102-0300
W9126G 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODE CODE
EMAIL: TEL:
The Solicitation for the Construction of the Earthen Covered Magazine; White Sands Missile Range, New Mexico is amended as follows.
W9126G21B0002
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
CHANGES TO SOLICITATION W9126G21B0002
CHANGES TO THE SPECIFICATIONS
1. Replacement Sections - Replace the following sections with the accompanying new sections of the same number and title, bearing the notation W9126G21B0002-0003.
01 35 20.00 44 SPECIAL PROJECT PROCEDURES FOR WHITE SANDS MISSILE RANGE
01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
CHANGES TO THE DRAWINGS
2. Replacement Drawings: Replace the drawings listed below with the attached new drawings with the same number, bearing the notation W9126G21B0002-0003.
ES-001 EXTERIOR ELECTRICAL LEGENDS
End of Summary of Changes
Construct Earthen Covered Magazine WS20ECM
SECTION 01 35 20.00 44
SPECIAL PROJECT PROCEDURES FOR WHITE SANDS MISSILE RANGE
AMENDMENT 0003
PART 1 GENERAL
1.1 NOTICE OF RESTRICTED ACCESS TO WHITE SANDS MISSILE RANGE
White Sands Missile Range is a restricted area in its entirety. Access to the Range by foreign nationals is not authorized unless approved on a case-by-case basis by the commander. The Contractors shall present to the Contracting Officer or his representative acceptable evidence of United States citizenship or bona fide immigrant alien status for each Contractor or sub-contractor employee who will perform work at this installation.
Requests for foreign national access shall be presented to the Contracting Officer at least 14 days prior to the desired access date. The following information must be included in each visit request: Name in full, security clearance, official title or position, nationality, visa, passport, order number, or serial number, date(s) desired and purpose of visit.
1.2 CONTRACTOR ACCESS PROGRAM
The Contractor and all associated sub-contractor employees shall provide all information required for background checks to meet installation access requirements to be accomplished by installation Directorate of Emergency Services or Security Office. Contractor workforce shall comply with all personal identity verification requirements (FAR Clause 52.204-9, Personal Identity Verification of Contractor Personnel) as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in contractor security matters or processes.
Contractors shall comply with the requirements of WSMR Visitor Control Program. The Government is not responsible for work delays or additional costs associated with Contractor's failure to obtain clearances for their employees.
1.2.1 Background Checks
The Contractor will be requested to furnish information to conduct background checks for each employee to the Security Directorate and/or Pass & Badge Office prior to access to the installation.
1.2.2 Identification of Employees
The Contractor shall be responsible for furnishing to each employee, and for requiring each employee engaged on the work to display, identification as approved and directed by the Contracting Officer. Prescribed identification shall immediately be delivered to the Contracting Officer for cancellation upon release of any employee. When required, the Contractor shall obtain and provide fingerprints of persons employed on the project. Contractor and subcontractor personnel shall wear
SECTION 01 35 20.00 44 Page 1
W9126G21B0002-0003 identifying markings on hard hats clearly identifying the company for whom the employee works. Contractor personnel shall wear visible Contractor-furnished employee identification badges while physically on the Installation. Each badge shall include, as a minimum, the company name, employee name, photograph, Contract Title, Contract Number, and the expiration date of the badge.
1.2.3 Construction Site Restricted Area Requirements
The construction site is located in a restricted area. Contractor shall be required to submit daily notification of personnel to be on site. Arrival and departure of each employee will be verified by the Government escort.
1.2.4 Utility Requirements
The following guidelines are provided: Utility outage permits are required. The contractor is responsible for the coordination and submitting all forms and sketches required for any outage. Utility, road and railroad closures require a minimum twenty one (21) working days advance written notice and will be subject to WSRO approval. In the case of a road closure a Traffic Control Plan in accordance with the Manual on Uniform Traffic Control Devices shall be provided at no additional cost to the government.
1.2.5 General Requirements
The Contractor is responsible for daily clean-up and completes restoration of the area once the contract is complete. Work shall be accomplished in accordance with all applicable contract documents.
1.2.6 Environmental Concerns
See Section 01 57 20.20 10 ENVIRONMENTAL PROTECTION FOR WHITE SANDS MISSILE RANGE for more detail.
1.3 Demolition Waste
All non-hazardous solid waste resulting from demolition operations (construction and demolition, C&D, debris) on WSMR shall be recycled and/or disposed of at an approved off-site solid waste or recycling facility. The contractor shall segregate and recycle, at a minimum, all scrap metal including, but not limited to, steel, aluminum, copper, copper wire, brass, and pipes. The contractor shall report to the WSMR Garrison Environmental Division Solid Waste Program Manager, the tons and type of material recycled and disposed, identify the recycling and disposal facility and provide the information to the government. The contractor shall be responsible for proper collection and disposal of all other non-hazardous solid waste (trash) generated at the job site. <AM#0003> Cardboard, paper, aluminum cans, soda and water bottles should be recycled in any available blue recycling trailer conveniently located on main post.
As an alternative to off-site disposal and recycling of C&D debris, the contractor is authorized to recycle scrap metal, asphalt, concrete and clean fill on-site. The contractor must coordinate with the WSMR Garrison Environmental Division Solid Waste Manager (678-2415) and complete and submit the WSMR Diverted/Stockpiled Materials Monthly Report Form. The contractor is authorized to dispose of other acceptable C&D debris at the on-site C&D landfill. The contractor shall report the tons and type of material recycled and disposed to the government. The contractor is
SECTION 01 35 20.00 44 Page 2 authorized to recycle all scrap metal including, but not limited to, steel, aluminum, copper, copper wire, brass, and pipes at the on-site scrap metal yard, Monday through Thursday, 7:30am to 11:30am and 12:30pm to 2:30pm.
Concrete shall be crushed in accordance with WSMR and New Mexico Air Quality regulations and government specifications. The contractor shall apply for a General Construction Permit (GCP) through New Mexico Environment Department. The contractor shall comply with the provisions (one of them is the use of water spray). Out of state contractors will need to provide a relocation notice from wherever they came from to New Mexico Environment Department as part of the GCP application. The contractor will coordinate with WSMR Garrison Environmental Division Air Quality Program Manager (678-2225) at the planning stage before crushing operation begins. </AM#0003>
"A satellite accumulation point (SAP) must be established by the contractor for accumulation of lead-based paint and asbestos waste generated during removal and abatement on WSMR. Contact the Hazardous Waste Management Center (HWMC), 678-4641, for further guidance. A SAP may also be required for proper management and disposal of paint related waste when other than latex or acrylic paint is used. An inventory of products to be used on WSMR, along with the manufacturer's SDS/MSDS, shall be provided to the HWMC prior to start of work.
1.4 DIGGING PERMIT AND UTILITY LOCATES
For all project activities requiring excavation, soil borings, or other subsurface work, the Contractor shall complete the attached WSMR Digging Permits in accordance with the Digging Permit Processes contain therein.
The Contractor is responsible for completing BOTH Digging Permits and obtain all required signatures/approvals to ensure all potential underground utilities and communication lines are identified. The Contractor shall allow a minimum of 45 calendar days for the WSMR Digging Permit Process from submission to Government Approval.
For the INFORMATION MANAGEMENT DIRECTORATE TRANSMISSION SECTION (WG-G6-DTE) EXCAVATION PERMIT, the form is to be filled out and e-mailed to Mr. Adam Carruth (adam.m.carruth.civ@mail.mil) and Mr. Danny Apodaca (daniel.d.apodaca2.civ@mail.mil). The WSMR Commo Group will mark/flag the commo lines in the area per the information provided, and when completed, e-mail the signed document back to the POC that submitted the locate request. The Commo group also signs the WSMR Digging Permit once the Commo Locate form and process has been completed.
For locates of utilities that do not belong to White Sands Missile Range, the Contractor shall submit a request through the website https://geocall.nm811.org/geocall/portal.
1.5 DRONE RESTRICTIONS
The use of drones, unmanned aircraft, or similar equipment is strictly prohibited at White Sands Missile Range. The Contractor may not utilize drones, unmanned aircraft, or similar equipment to perform any onsite work related to this contract.
SECTION 01 35 20.00 44 Page 3
PART 2 PRODUCTS (NOT APPLICABLE)
PART 3 EXECUTION (NOT APPLICABLE)
-- End of Section --
SECTION 01 35 20.00 44 Page 4
SECTION 01 50 00
TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS
AMENDMENT 0003
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2020; ERTA 20-1 2020; ERTA 20-2 2020; TIA
20-1; TIA 20-2; TIA 20-3; TIA 20-4)
National Electrical Code
NFPA 241 (2019) Standard for Safeguarding Construction, Alteration, and Demolition Operations
U.S. ARMY CORPS OF ENGINEERS (USACE)
EM 385-1-1 (2014) Safety and Health Requirements Manual
U.S. FEDERAL HIGHWAY ADMINISTRATION (FHWA)
MUTCD (2009; Rev 2012) Manual on Uniform Traffic Control Devices
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-01 Preconstruction Submittals
Construction Site Plan ; G
Traffic Control Plan ; G
Haul Road Plan ; G
Contractor Computer Cybersecurity Compliance Statements ; G
Contractor Temporary Network Cybersecurity Compliance Statements ; G
SECTION 01 50 00 Page 1
1.3 CONSTRUCTION SITE PLAN
Prior to the start of work, submit for Government approval a site plan showing the locations and dimensions of temporary facilities (including layouts and details, equipment and material storage area (onsite and offsite), and access and haul routes, avenues of ingress/egress to the fenced area and details of the fence installation. Identify any areas which may have to be graveled to prevent the tracking of mud. Indicate if the use of a supplemental or other staging area is desired. Show locations of safety and construction fences, site trailers, construction entrances, trash dumpsters, temporary sanitary facilities, and worker parking areas.
1.4 DOD CONDITION OF READINESS (COR)
DOD will set the Condition of Readiness (COR) based on the weather forecast for sustained winds 50 knots ( 58 mph ) or greater. Contact the Contracting Officer for the current COR setting.
Monitor weather conditions a minimum of twice a day and take appropriate actions according to the approved Emergency Plan in the accepted Accident Prevention Plan, EM 385-1-1 Section 01 Emergency Planning and the instructions below.
Unless otherwise directed by the Contracting Officer, comply with:
a. Condition FOUR (Sustained winds of 58 mph or greater expected within 72 hours): Normal daily jobsite cleanup and good housekeeping practices. Collect and store in piles or containers scrap lumber, waste material, and rubbish for removal and disposal at the close of each work day. Maintain the construction site including storage areas, free of accumulation of debris. Stack form lumber in neat piles less than 3.3 feet high. Remove all debris, trash, or objects that could become missile hazards. Review requirements pertaining to "Condition THREE" and continue action as necessary to attain "Condition FOUR" readiness. Contact Contracting Officer for weather and COR updates and completion of required actions.
b. Condition THREE (Sustained winds of 58 mph or greater expected within 48 hours): Maintain "Condition FOUR" requirements and commence securing operations necessary for "Condition ONE" which cannot be completed within 18 hours. Cease all routine activities which might interfere with securing operations. Commence securing and stow all gear and portable equipment. Make preparations for securing buildings. Reinforce or remove formwork and scaffolding. Secure machinery, tools, equipment, materials, or remove from the jobsite.
Expend every effort to clear all missile hazards and loose equipment from general base areas. Contact Contracting Officer for weather and COR updates and completion of required actions. Review requirements pertaining to "Condition TWO" and continue action as necessary to attain "Condition THREE" readiness.
c. Condition TWO (Sustained winds of 58 mph or greater expected within 24 hours): Secure the jobsite, and leave Government premises.
d. Condition ONE. (Sustained winds of 58 mph or greater expected within 12 hours): Contractor access to the jobsite and Government premises is prohibited.
SECTION 01 50 00 Page 2
1.5 CYBERSECURITY DURING CONSTRUCTION
{For Reference Only: This subpart (and its subparts) relates to AC-18, SA-3, CCI-00258.} Meet the following requirements throughout the construction process.
1.5.1 Contractor Computer Equipment
Contractor owned computers may be used for construction. When used, contractor computers must meet the following requirements:
1.5.1.1 Operating System
The operating system must be an operating system currently supported by the manufacturer of the operating system. The operating system must be current on security patches and operating system manufacturer required updates.
1.5.1.2 Anti-Malware Software
The computer must run anti-malware software from a reputable software manufacturer. Anti-malware software must be a version currently supported by the software manufacturer, must be current on all patches and updates, and must use the latest definitions file. All computers used on this project must be scanned using the installed software at least once per day.
1.5.1.3 Passwords and Passphrases
The passwords and passphrases for all computers must be changed from their default values. Passwords must be a minimum of eight characters with a minimum of one uppercase letter, one lowercase letter, one number and one special character.
1.5.1.4 Contractor Computer Cybersecurity Compliance Statements
Provide a single submittal containing completed Contractor Computer Cybersecurity Compliance Statements for each company using contractor owned computers. Contractor Computer Cybersecurity Compliance Statements must use the template published at http://www.wbdg.org/ffc/dod/unified-facilities-guide-specifications-ufgs/forms-graphics-tables . Each Statement must be signed by a cybersecurity representative for the relevant company.
1.5.2 Temporary IP Networks
Temporary contractor-installed IP networks may be used during construction. When used, temporary contractor-installed IP networks must meet the following requirements:
1.5.2.1 Network Boundaries and Connections
The network must not extend outside the project site and must not connect to any IP network other than IP networks provided under this project or Government furnished IP networks provided for this purpose. Any and all network access from outside the project site is prohibited.
SECTION 01 50 00 Page 3
1.5.3 Government Access to Network
Government personnel must be allowed to have complete and immediate access to the network at any time in order to verify compliance with this specification.
1.5.4 Temporary Wireless IP Networks
In addition to the other requirements on temporary IP networks, temporary wireless IP (WiFi) networks must not interfere with existing wireless network and must use WPA2 security. Network names (SSID) for wireless networks must be changed from their default values.
1.5.5 Passwords and Passphrases
The passwords and passphrases for all network devices and network access must be changed from their default values. Passwords must be a minimum 8 characters with a minimum of one uppercase letter, one lowercase letter, one number and one special character.
1.5.6 Contractor Temporary Network Cybersecurity Compliance Statements
Provide a single submittal containing completed Contractor Temporary Network Cybersecurity Compliance Statements for each company implementing a temporary IP network. Contractor Temporary Network Cybersecurity Compliance Statements must use the template published at http://www.wbdg.org/ffc/dod/unified-facilities-guide-specifications-ufgs/ forms-graphics-tables . Each Statement must be signed by a cybersecurity representative for the relevant company. If no temporary IP networks will be used, provide a single copy of the Statement indicating this.
PART 2 PRODUCTS
2.1 TEMPORARY SIGNAGE
2.1.1 Bulletin Board
Prior to the commencement of work activities, provide a clear weatherproof covered bulletin board not less than 36 by 48 inches in size for displaying the Equal Employment Opportunity poster, a copy of the wage decision contained in the Contract, Wage Rate Information poster, Safety and Health Information as required by EM 385-1-1 Section 01 and other information approved by the Contracting Officer. Coordinate requirements herein with 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS. Locate the bulletin board at the project site in a conspicuous place easily accessible to all employees, and in location as approved by the Contracting Officer.
2.1.2 Project Identification Signs
The requirements for the signs, their content, and location are as specified in Section 01 58 00 PROJECT IDENTIFICATION. Erect signs within 15 days after receipt of the notice to proceed. Correct the data required by the safety sign daily, with light colored metallic or non-metallic numerals.
2.1.3 Warning Signs
Post temporary signs, tags, and labels to give workers and the public
SECTION 01 50 00 Page 4 adequate warning and caution of construction hazards according to the EM 385-1-1 Section 04. Attach signs to the perimeter fencing every 150 feet warning the public of the presence of construction hazards. Signs must require unauthorized persons to keep out of the construction site.
Correct the data required by safety signs daily. Post signs at all points of entry designating the construction site as a hard hat area.
2.2 TEMPORARY TRAFFIC CONTROL
2.2.1 Haul Roads
Construct access and haul roads necessary for proper prosecution of the work under this Contract in accordance with EM 385-1-1 Section 04.
Construct with suitable grades and widths; avoid sharp curves, blind corners, and dangerous cross traffic. Submit haul road plan for approval. Provide necessary lighting, signs, barricades, and distinctive markings for the safe movement of traffic. The method of dust control, although optional, must be adequate to ensure safe operation at all times. Location, grade, width, and alignment of construction and haul roads are subject to approval by the Contracting Officer. Lighting must be adequate to assure full and clear visibility for full width of haul road and work areas during any night work operations.
2.2.2 Barricades
Erect and maintain temporary barricades to limit public access to hazardous areas. Barricades are required whenever safe public access to paved areas such as roads, parking areas or sidewalks is prevented by construction activities or as otherwise necessary to ensure the safety of both pedestrian and vehicular traffic. Securely place barricades clearly visible with adequate illumination to provide sufficient visual warning of the hazard during both day and night.
2.3 FENCING
Provide fencing along the construction site and at all open excavations and tunnels to control access by unauthorized personnel. Safety fencing must be highly visible to be seen by pedestrians and vehicular traffic.
All fencing must meet the requirements of EM 385-1-1 . Remove the fence upon completion and acceptance of the work.
2.3.1 Polyethylene Mesh Safety Fencing
Temporary safety fencing must be a high visibility orange colored, high density polyethylene grid, a minimum of 48 inches high and maximum mesh size of 2 inches . Fencing must extend from the grade to a minimum of 48 inches above the grade and be tightly secured to T-posts spaced as necessary to maintain a rigid and taut fence. Fencing must remain rigid and taut with a minimum of 200 pounds of force exerted on it from any direction with less than 4 inches of deflection.
2.3.2 Chain Link Panel Fencing
Temporary panel fencing must be galvanized steel chain link panels 6 feet high. Multiple fencing panels may be linked together at the bases to form long spans as needed. Each panel base must be weighted down using sand bags or other suitable materials in order for the fencing to withstand anticipated winds while remaining upright. Fencing must remain rigid and taut with a minimum of 200 pounds of force exerted on it from any
SECTION 01 50 00 Page 5 direction with less than 4 inches of deflection.
2.3.3 Post-Driven Chain Link Fencing
Temporary post-driven fencing must be galvanized chain link fencing 6 feet high supported by an tightly secured to galvanized steel posts driven below grade. Fence posts must be located on minimum 10 foot centers.
Posts may be set in various surfaces such as sand, soil, asphalt or concrete as necessary. Chain link fencing must remain rigid and taut with a minimum of 200 pounds of force exerted on it from any direction with less than 4 inches of deflection. Completely remove fencing and posts at the completion of construction and restore surfaces disturbed or damaged to its original condition. Locate and identify underground utilities prior to setting fence posts. Equip fence with a lockable gate. Gate must remain locked when construction personnel are not present.
2.4 TEMPORARY WIRING
Provide temporary wiring in accordance with EM 385-1-1 Section 11, NFPA 241 and NFPA 70 . Include monthly inspection and testing of all equipment and apparatus.
PART 3 EXECUTION
3.1 EMPLOYEE PARKING
Construction Contract employees must park privately owned vehicles in an area designated by the Contracting Officer. Employee parking must not interfere with existing and established parking requirements of the Government installation.
3.2 AVAILABILITY AND USE OF UTILITY SERVICES
3.2.1 Temporary Utilities
Provide temporary utilities required for construction. Materials may be new or used, must be adequate for the required usage, not create unsafe conditions, and not violate applicable codes and standards.
3.2.2 Payment for Utility Services
a. <AM#0003>The Government will make all reasonably required utilities available from existing outlets and supplies, as specified in the contract. Unless otherwise provided in the contract, the amount of each utility service consumed will be charged to or paid at prevailing rates charged to the Government or, where the utility is produced by the Government, at reasonable rates determined by the Contracting Officer. Carefully conserve any utilities furnished without charge.
Water is available from a fire hydrant located at the corner of Nike Road and Route 220, approximately one mile from the N79 Magazine project site. Water is provided at no cost. Contractor is responsible for providing a back-flow preventer and coordination of the connection to hydrant with the WSMR Water Shop and COR.
3.2.3 Meters and Temporary Connections
Provide and maintain necessary temporary connections, distribution lines, and meter bases (Government will provide meters) required to measure the amount of each utility used for the purpose of determining charges.
SECTION 01 50 00 Page 6
Notify the Contracting Officer, in writing, 5 working days before final electrical connection is desired so that a utilities contract can be established. The Government will provide a meter and make the final hot connection after inspection and approval of the Contractor's temporary wiring installation. Do not make the final electrical connection.
3.2.4 Advance Deposit
An advance deposit for utilities consisting of an estimated month's usage or a minimum of $50.00 will be required. The last monthly bills for the fiscal year will normally be offset by the deposit and adjustments will be billed or returned as appropriate. Services to be rendered for the next fiscal year, beginning 1 October, will require a new deposit.
Notification of the due date for this deposit will be mailed prior to the end of the current fiscal year.
3.2.5 Final Meter Reading
Before completion of the work and final acceptance of the work by the Government, notify the Contracting Officer, in writing, 5 working days before termination is desired. The Government will take a final meter reading, disconnect service, and remove the meters. Then remove all the temporary distribution lines, meter bases, and associated paraphernalia.
Pay all outstanding utility bills before final acceptance of the work by the Government.
</AM#0003> 3.2.3 Sanitation
Provide and maintain within the construction area minimum field-type sanitary facilities in accordance with EM 385-1-1 Section 02. Locate the facilities behind the construction fence or out of the public view. Clean units and empty wastes at least once a week or more frequently into a municipal, district, or station sanitary sewage system, or remove waste to a commercial facility. Obtain approval from the system owner prior to discharge into a municipal, district, or commercial sanitary sewer system. Penalties or fines associated with improper discharge will be the responsibility of the Contractor. Coordinate with the Contracting Officer and follow station regulations and procedures when discharging into the station sanitary sewer system. Maintain these conveniences at all times.
Include provisions for pest control and elimination of odors. Government toilet facilities will not be available to Contractor's personnel.
3.2.4 Telephone
Make arrangements and pay all costs for telephone facilities desired.
3.2.5 Fire Protection
Provide temporary fire protection equipment for the protection of personnel and property during construction. Remove debris and flammable materials daily to minimize potential hazards.
3.3 STATION OPERATION AFFECT ON CONTRACTOR OPERATIONS
3.3.1 Restricted Access Areas
The Government will monitor work in areas indicated. Notify Contracting Officer at least 14 calendar days prior to starting work in these areas.
SECTION 01 50 00 Page 7
3.4 TRAFFIC PROVISIONS
3.4.1 Maintenance of Traffic
a. Conduct operations in a manner that will not close a thoroughfare or interfere with traffic on railways or highways except with written permission of the Contracting Officer at least 15 calendar days prior to the proposed modification date, and provide a Traffic Control Plan for Government approval detailing the proposed controls to traffic movement for approval. The plan must be in accordance with State and local regulations and the MUTCD, Part VI. Make all notifications and obtain all permits required for modification to traffic movements outside Station's jurisdiction.. Contractor may move oversized and slow-moving vehicles to the worksite provided requirements of the highway authority have been met.
b. Conduct work so as to minimize obstruction of traffic, and maintain traffic on at least half of the roadway width at all times. Obtain approval from the Contracting Officer prior to starting any activity that will obstruct traffic.
c. Provide, erect, and maintain, at Contractor's expense, lights, barriers, signals, passageways, detours, and other items, that may be required by the Life Safety Signage, overhead protection authority having jurisdiction.
d. Provide cones, signs, barricades, lights, or other traffic control devices and personnel required to control traffic. Do not use foil-backed material for temporary pavement marking because of its potential to conduct electricity during accidents involving downed power lines.
3.4.2 Protection of Traffic
Maintain and protect traffic on all affected roads during the construction period except as otherwise specifically directed by the Contracting Officer. Measures for the protection and diversion of traffic, including the provision of watchmen and flagmen, erection of barricades, placing of lights around and in front of equipment the work, and the erection and maintenance of adequate warning, danger, and direction signs, will be as required by the State and local authorities having jurisdiction. Provide self-illuminated (lighted) barricades during hours of darkness.
Brightly-colored (orange) vests are required for all personnel working in roadways. Protect the traveling public from damage to person and property. Minimize the interference with public traffic on roads selected for hauling material to and from the site. Investigate the adequacy of existing roads and their allowable load limit. Contractor is responsible for the repair of damage to roads caused by construction operations.
3.4.3 Rush Hour Restrictions
Do not interfere with the peak traffic flows preceding and during normal operations without notification to and approval by the Contracting Officer.
3.4.4 Dust Control
Dust control methods and procedures must be approved by the Contracting Officer. Coordinate dust control methods with 01 56 00.00 44 DUST CONTROL.
SECTION 01 50 00 Page 8
3.5 CONTRACTOR'S TEMPORARY FACILITIES
Contractor-owned or -leased trailers must be identified by Government assigned numbers. Apply the number to the trailer within 14 calendar days of notification, or sooner, if directed by the Government. Temporary facilities must meet requirements as identified in EM 385-1-1 Section 04.
Contractor field office facilities shall be located at the designated "Contractors' Row" site on the main campus of White Sands Missile Range.
The coordinates for Contractors' Row are 32°22'22.6"N 106°28'32.1"W. The use of Contractors' Row is at no cost to the Contractor. Specific details for coordinating the utilization of space at Contractors' Row will be provided by the Contracting Officer's Representative during the Pre-Construction Conference.
Contractor is responsible for security of their property. Provide adequate outside security lighting at the temporary facilities. Trailers must be anchored to resist high winds and meet applicable state or local standards for anchoring mobile trailers. Coordinate anchoring with EM 385-1-1 Section 04. The Contract Clause entitled "FAR 52.236-10, Operations and Storage Areas" and the following apply:
3.5.1 Administrative Field Offices
Government office and warehouse facilities will not be available to the Contractor's personnel.
3.5.2 Storage Area
Construct a temporary 6 foot high chain link fence around trailers and materials. Include plastic strip inserts, colored brown, so that visibility through the fence is obstructed. Fence posts may be driven, in lieu of concrete bases, where soil conditions permit. Do not place or store trailers, materials, or equipment outside the fenced area unless such trailers, materials, or equipment are assigned a separate and distinct storage area by the Contracting Officer away from the vicinity of the construction site but within the installation boundaries. Trailers, equipment, or materials must not be open to public view with the exception of those items which are in support of ongoing work on the current day.
Do not stockpile materials outside the fence in preparation for the next day's work. Park mobile equipment, such as tractors, wheeled lifting equipment, cranes, trucks, and like equipment within the fenced area at the end of each work day.
Keep fencing in a state of good repair and proper alignment. Grassed or unpaved areas, which are not established roadways, and will be traversed with construction equipment or other vehicles, must be covered with a layer of gravel as necessary to prevent rutting and the tracking of mud onto paved or established roadways, should the Contractor elect to traverse them with construction equipment or other vehicles. Mow and maintain grass located within the boundaries of the construction site for the duration of the project. Grass and vegetation along fences, buildings, under trailers, and in areas not accessible to mowers must be edged or trimmed neatly.
3.5.3 Appearance of Trailers
a. Trailers must be roadworthy and comply with all appropriate state and local vehicle requirements. Trailers which are rusted, have peeling paint or are otherwise in need of repair will not be allowed on
SECTION 01 50 00 Page 9
Installation property. Trailers must present a clean and neat exterior appearance and be in a state of good repair.
b. Maintain the temporary facilities. Failure to do so will be sufficient reason to require their removal at the Contractor's expense.
3.5.4 Safety Systems
Protect the integrity of all installed safety systems or personnel safety devices. Obtain prior approval from the Contracting Officer if entrance into systems serving safety devices is required. If it is temporarily necessary to remove or disable personnel safety devices in order to accomplish Contract requirements, provide alternative means of protection prior to removing or disabling any permanently installed safety devices or equipment and obtain approval from the Contracting Officer.
3.5.5 Weather Protection of Temporary Facilities and Stored Materials
Take necessary precautions to ensure that roof openings and other critical openings in the building are monitored carefully. Take immediate actions required to seal off such openings when rain or other detrimental weather is imminent, and at the end of each workday. Ensure that the openings are completely sealed off to protect materials and equipment in the building from damage.
3.5.5.1 Building and Site Storm Protection
When a warning of gale force winds is issued, take precautions to minimize danger to persons, and protect the work and nearby Government property.
Precautions must include, but are not limited to, closing openings;
removing loose materials, tools and equipment from exposed locations; and removing or securing scaffolding and other temporary work. Close openings in the work when storms of lesser intensity pose a threat to the work or any nearby Government property.
3.6 PLANT COMMUNICATIONS
Whenever the individual elements of the plant are located so that operation by normal voice between these elements is not satisfactory, install a satisfactory means of communication, such as telephone or other suitable devices and make available for use by Government personnel.
3.7 TEMPORARY PROJECT SAFETY FENCING
As soon as practicable, but not later than 15 days after the date established for commencement of work, furnish and erect temporary project safety fencing at the work site. Maintain the safety fencing during the life of the Contract and, upon completion and acceptance of the work, remove from the work site.
3.8 CLEANUP
Remove construction debris, waste materials, packaging material and the like from the work site daily. Any dirt or mud which is tracked onto paved or surfaced roadways must be cleaned away. Store all salvageable materials resulting from demolition activities within the fenced area described above or at the supplemental storage area. Neatly stack stored materials not in trailers, whether new or salvaged.
SECTION 01 50 00 Page 10
3.9 RESTORATION OF STORAGE AREA
Upon completion of the project remove the bulletin board, signs, barricades, haul roads, and all other temporary products from the site.
After removal of trailers, materials, and equipment from within the fenced area, remove the fence. Restore areas used during the performance of the Contract to the original or better condition. Remove gravel used to traverse grassed areas and restore the area to its original condition, including top soil and seeding as necessary.
-- End of Section --
SECTION 01 50 00 Page 11
ES-001
E X
T E
R I O
R
E
L E
C T
R I C
A L
L
G
E N
D S
T
N G
U Y
E N
T
N G
U Y
E N
US Army Corps of
Engineers ®
SHEET
NUMBER
D r a w n b y
D e s i g n e d b y
S u b m i t t e d b y
S h e e t
S i z e
A N
S I
D
D a t e
C o n t r a c t
N o
S o l i c i t a t i o n
N o
U S
A
R M
Y
C
O R
P S
O
F
E
N G
I N
E E
R S
F O
R T
W
R
H
D
I S
T R
I C
T
T
A Y
L O
R
S
T R
E E
T
F O
R
R
T H
T
E X
A S
C h e c k e d b y
A
R e v
M a r k
D e s c r i p t i o n
T r a c k i n g
N o
A c t i o n
D a t e
E N
G I N
E E
R I N
G
C O
N S
T R
U C
T I O
N
D
I V
I S
I O
N
E N
G I N
E E
R I N
G
B
R A
N C
H
PLOT DATE:
2 3 4 5 6
7 8 9 10
B
C
D
E
F
G
FILE PATH:
W G
B
W H
I T
E
S
A N
S
M
I S
S I L
E
R
A N
G E
W H
I T
E
S
A N
D S
N
X
I C
O
C O
N S
T R
U C
T
E
A R
T H
N
C
V
E R
G
A Z
I N
E
N
F Y
P
N
M A
Y
Fort Worth District
T
A V
E R
Y
P
E
D A
R E
N
A
B
R O
W N
P
E
C H
I E
F
E
L E
C T
R I C
A L
S
E C
T I O
N
GENERAL SHEET NOTES :
1. WSMR PRIMARY SYSTEM VOLTAGE IS 7200/12470V.
2. ALL NEW OR MODIFIED UTILITY POLES REQUIRED
UNDER THIS CONTRACT SHALL INCLUDE RAPTOR
PROTECTION. THE PRIMARY OBJECTIVE IS TO
ACHIEVE THE REQUIRED SEPARATION DISTANCE
(RELATED TO RAPTOR HEIGHT AND WING-SPAN)
BETWEEN GROUNDED AND ENERGIZED
COMPONENTS, AND BETWEEN ENERGIZED
COMPONENTS. RAPTOR PROTECTION MEASURES
SHALL INCLUDE, BUT ARE NOT LIMITED TO, COVERED
GROUND WIRES, INSULATED GUY LINKS,
CONDUCTOR COVERS, DEAD-END COVERS,
INSULATED JUMPER WIRES, TRANSFORMER BUSHING
COVERS, CUT-OUT AND LOAD-BREAK COVERS, AND
ARRESTOR COVERS. RAPTOR PROTECTION SHALL BE
COMPLIANT WITH THE 2014 WSMR AVIAN
PROTECTION PLAN (SPECIFICATION APPENDIX B).
3. THE MODULAR STORAGE MAGAZINE DRAWINGS, E-101
TO E-313 ARE NAVY STANDARD DRAWINGS AND
CANNOT BE CHANGED. THERE ARE THREE ERRORS
IN THE DRAWINGS. ON SHEET E-312, DETAIL 4
REFERS TO SHEET E-102 FOR THE SECONDARY
GROUNDING RING. THE GROUNDING RING IS SHOWN
ON SHEET E-310. ON SHEET E-312, DETAIL 3
REFERENCES SHEET E-103 FOR LOCATION OF AIR
TERMINALS. THE LOCATION OF AIR TERMINALS IS
SHOWN ON SHEET E-310. IN DETAIL 2 ON SHEET E-312
IT SAYS SEE ORDINANCE GROUND INSERT DETAIL ON
SHEET E-106. THE ORDINANCE GROUND INSERT
DETAIL IS ACTUALLY ON SHEET E-313.
ADVANCED ELECTRIC METER
M
NEW BUNKER
KEYED NOTE REFERENCE.
DESCRIPTION
EXISTING TO
3/4IN COPPER CLAD 10FT GROUND ROD
EXTERIOR ELECTRICAL LEGEND
TRANSFORMER; POLE MOUNTED
UTILITY POLE; 40FT; CLASS 2; RAPTOR PROTECTION;
NEW SYMBOL
COMMUNICATION PULLBOX
GUY POLE WIRE
DOWNGUY. NUMBER INDICATES STRENGTH.
OVERHEAD PRIMARY LINE
UNDERGROUND SECONDARY LINE
DISCONNECT SWITCH
x
UGC
C
UNDERGROUND COMMUNICATION LINE.
CMH
CMH
REMAIN
EXISTING TO
BE REMOVED
x
UGC
GROUND ROD, 10FT 3/4IN. COPPER CLAD.
POLE MOUNTED TRANSFORMER.
NUMBER INDICATES KVA RATING.
c c c c
G
N
E R
A L
N
O T
E
W9126G21B0002-0003
AutoCAD SHX Text
AutoCAD SHX Text _kVA
AutoCAD SHX Text
ES
AutoCAD SHX Text
OHE
AutoCAD SHX Text
OHE
AutoCAD SHX Text x
AutoCAD SHX Text
OHE
AutoCAD SHX Text x
AutoCAD SHX Text
ES
AutoCAD SHX Text x
AutoCAD SHX Text
ES
AutoCAD SHX Text x
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| AMENDMENT 0003 |
| SUMMARY OF CHANGES |
| CHANGES TO THE SPECIFICATIONS |
| 01 35 20.00 44 - SPECIAL PROJECT PROCEDURES FOR WHITE SANDS MISSILE RANGE |
| PART 1 GENERAL |
| 1.1 NOTICE OF RESTRICTED ACCESS TO WHITE SANDS MISSILE RANGE |
| 1.2 CONTRACTOR ACCESS PROGRAM |
| 1.2.1 Background Checks |
| 1.2.2 Identification of Employees |
| 1.2.3 Construction Site Restricted Area Requirements |
| 1.2.4 Utility Requirements |
| 1.2.5 General Requirements |
| 1.2.6 Environmental Concerns |
| 1.3 Demolition Waste |
| 1.4 DIGGING PERMIT AND UTILITY LOCATES |
| 1.5 DRONE RESTRICTIONS |
| PART 2 PRODUCTS NOT APPLICABLE |
| PART 3 EXECUTION NOT APPLICABLE |
| 01 50 00 - TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 CONSTRUCTION SITE PLAN |
| 1.4 DOD CONDITION OF READINESS COR |
| 1.5 CYBERSECURITY DURING CONSTRUCTION |
| 1.5.1 Contractor Computer Equipment |
| 1.5.1.1 Operating System |
| 1.5.1.2 Anti-Malware Software |
| 1.5.1.3 Passwords and Passphrases |
| 1.5.1.4 Contractor Computer Cybersecurity Compliance Statements |
| 1.5.2 Temporary IP Networks |
| 1.5.2.1 Network Boundaries and Connections |
| 1.5.3 Government Access to Network |
| 1.5.4 Temporary Wireless IP Networks |
| 1.5.5 Passwords and Passphrases |
| 1.5.6 Contractor Temporary Network Cybersecurity Compliance Statements |
| PART 2 PRODUCTS |
| 2.1 TEMPORARY SIGNAGE |
| 2.1.1 Bulletin Board |
| 2.1.2 Project Identification Signs |
| 2.1.3 Warning Signs |
| 2.2 TEMPORARY TRAFFIC CONTROL |
| 2.2.1 Haul Roads |
| 2.2.2 Barricades |
| 2.3 FENCING |
| 2.3.1 Polyethylene Mesh Safety Fencing |
| 2.3.2 Chain Link Panel Fencing |
| 2.3.3 Post-Driven Chain Link Fencing |
2.4 TEMPORARY WIRING
| PART 3 EXECUTION |
| 3.1 EMPLOYEE PARKING |
| 3.2 AVAILABILITY AND USE OF UTILITY SERVICES |
| 3.2.1 Temporary Utilities |
| 3.2.2 Payment for Utility Services |
| 3.2.3 Sanitation |
| 3.2.4 Telephone |
| 3.2.5 Fire Protection |
| 3.3 STATION OPERATION AFFECT ON CONTRACTOR OPERATIONS |
| 3.3.1 Restricted Access Areas |
| 3.4 TRAFFIC PROVISIONS |
| 3.4.1 Maintenance of Traffic |
| 3.4.2 Protection of Traffic |
| 3.4.3 Rush Hour Restrictions |
| 3.4.4 Dust Control |
| 3.5 CONTRACTOR'S TEMPORARY FACILITIES |
| 3.5.1 Administrative Field Offices |
| 3.5.2 Storage Area |
| 3.5.3 Appearance of Trailers |
| 3.5.4 Safety Systems |
| 3.5.5 Weather Protection of Temporary Facilities and Stored Materials |
| 3.5.5.1 Building and Site Storm Protection |
| 3.6 PLANT COMMUNICATIONS |
| 3.7 TEMPORARY PROJECT SAFETY FENCING |
| 3.8 CLEANUP |
| 3.9 RESTORATION OF STORAGE AREA |
| CHANGES TO THE DRAWINGS |
| ES001 |
File details come from the government source that posted it. Updated .