Safety Data Sheet - Propylene Glycol Ind.PDF
PDF 226 KB Posted
- Attached to
- Temperature and Humidity Environmental Chamber Amendment 0001 Federal contract opportunity
- Solicitation number
- W9124P-21-R-0011
About this file
This document contains a solicitation for a temperature and humidity environmental chamber. The Army Materiel Command Contracting Command Redstone Arsenal is seeking proposals for one new chamber to be used for conducting environmental testing and conditioning of packaging materials and packages at the ASC Packaging, Storage, and Containerization Center. Proposals are due no later than August 23, 2021 at 4 PM CST and shall be submitted by email only to the identified contracting officer and contract specialist. The solicitation is issued as a request for firm fixed price proposals under NAICS code 333415 with a size standard of 1250 employees. The chamber must be delivered within eight months of order receipt. Inspection, acceptance, and terms of delivery are specified as destination.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W9124P-21-R-0011_22Jul2021.pdf | ||
| PWS_Environmental Chamber June2021V2.docx.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Safety Data Sheet
Propylene glycol Industrial
Version 1.4 Revision Date: 04/03/2017
SDS Number: 100000003334 1 / 9 Propylene glycol Industrial
SECTION 1. PRODUCT AND COMPANY IDENTIFICATION
Product name : Propylene glycol Industrial
Recommended use of the chemical and restrictions on use
Recommended use : Industrial chemical
Manufacturer or supplier's details Company : Nexeo Solutions, LLC.
Address 3 Waterway Square Place Suite 1000
The Woodlands, TX. 77380 United States of America
Emergency telephone number:
Health North America: 1-855-NEXEO4U (1-855-639-3648) Health International: 1-855-NEXEO4U (1-855-639-3648) Transport North America: CHEMTREC (1-800-424-9300)
Additional Information:
: Responsible Party: Product Safety Group E-Mail: msds@nexeosolutions.com SDS Requests: 1-855-429-2661 SDS Requests Fax: 1-281-500-2370 Website: www.nexeosolutions.com
SECTION 2. HAZARDS IDENTIFICATION
GHS Classification
Not a hazardous substance or mixture.
GHS Label element
Not a hazardous substance or mixture.
Other hazards
None known.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Substance / Mixture
: Substance
Hazardous components
CAS-No. Chemical Name Weight %
57-55-6 Propylene glycol 90 - 100
Any Concentration shown as a range is due to batch variation.
SECTION 4. FIRST AID MEASURES
General advice
: Do not leave the victim unattended.
If inhaled
: If unconscious place in recovery position and seek medical advice.
If symptoms persist, call a physician.
SDS Number: 100000003334 2 / 9 Propylene glycol Industrial
In case of skin contact
: Wash off with soap and water.
Wash contaminated clothing before reuse.
Get medical attention if irritation develops and persists.
In case of eye contact
: Remove contact lenses.
Protect unharmed eye.
If eye irritation persists, consult a specialist.
If swallowed
: Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.
Do not induce vomiting without medical advice.
SECTION 5. FIREFIGHTING MEASURES
Suitable extinguishing media
: Carbon dioxide (CO2) Foam Dry chemical
Unsuitable extinguishing media
: High volume water jet
Specific hazards during fire-fighting
: Do not allow run-off from fire fighting to enter drains or water courses.
Hazardous combustion prod-ucts
: No hazardous combustion products are known
Further information : Standard procedure for chemical fires.
Use extinguishing measures that are appropriate to local cir-cumstances and the surrounding environment.
Special protective equipment for firefighters
: Wear self-contained breathing apparatus for firefighting if nec-essary.
Use personal protective equipment.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Methods and materials for containment and cleaning up
: Wipe up with absorbent material (e.g. cloth, fleece).
Keep in suitable, closed containers for disposal.
SECTION 7. HANDLING AND STORAGE
Advice on protection against fire and explosion
: Normal measures for preventive fire protection.
Advice on safe handling
: For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the ap-
SDS Number: 100000003334 3 / 9 Propylene glycol Industrial plication area.
Conditions for safe storage
: Electrical installations / working materials must comply with the technological safety standards.
Materials to avoid
: No materials to be especially mentioned.
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Components with workplace control parameters
CAS-No. Components Value type (Form of exposure)
Control parame-ters / Permissible concentration
Basis
57-55-6 Propylene glycol TWA 10 mg/m3 US WEEL
Personal protective equipment
Respiratory protection
: General and local exhaust ventilation is recommended to maintain vapor exposures below recommended limits. Where concentrations are above recommended limits or are un-known, appropriate respiratory protection should be worn.
Follow OSHA respirator regulations (29 CFR 1910.134) and use NIOSH/MSHA approved respirators. Protection provided by air purifying respirators against exposure to any hazardous chemical is limited. Use a positive pressure air supplied respi-rator if there is any potential for uncontrolled release, expo-sure levels are unknown, or any other circumstance where air purifying respirators may not provide adequate protection.
Eye protection
: Safety glasses
Skin and body protection
: Protective suit
Hygiene measures
: General industrial hygiene practice.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
: liquid
Colour
: Clear, Colorless
Odour
: odourless, mild
Odour Threshold
: No data available pH
: 7 @ 20 - 25 °C (68 - 77 °F)
Freezing Point (Melting point/freezing point)
: -60 - -20 °C (-76 - -4 °F)
Boiling Point (Boiling : 184 - 188 °C (363 - 370 °F)
SDS Number: 100000003334 4 / 9 Propylene glycol Industrial point/boiling range)
Flash point
: 103 °C (217 °F)
Evaporation rate
: < 0.02 (Butyl Acetate = 1)
Flammability (solid, gas)
Upper explosion limit
: 17.4 %(V)
Lower explosion limit
: 2.4 %(V)
Vapour pressure
: < 0.225 mmHg @ 25 °C (77 °F)
Relative vapour density
: < 2.62 @ 15 - 32 °C (59 - 90 °F) (Air = 1.0)
Relative density
: 1.03 - 1.04 @ 20 - 25 °C (68 - 77 °F) Reference substance: (water = 1)
Density
: 1.03 - 1.04 g/cm3 @ 20 - 25 °C (68 - 77 °F)
Solubility(ies) Water solubility
: soluble
Solubility in other solvents
Partition coefficient: n-octanol/water
: log Pow: -1.07 - -0.92
Auto-ignition temperature
: 371 - 400 °C
Thermal decomposition
Viscosity Viscosity, dynamic
: 43 - 56 mPa.s @ 20 - 25 °C (68 - 77 °F)
Viscosity, kinematic
: 42.1 mm2/s @ 25 °C (77 °F)
< 20 mm2/s @ 40 °C (104 °F)
Surface tension
: 71.6 mN/m, 21.5 °C
SECTION 10. STABILITY AND REACTIVITY
Reactivity
: No dangerous reaction known under conditions of normal use.
Chemical stability
: Stable under normal conditions.
Possibility of hazardous reac-tions
: No hazards to be specially mentioned.
SDS Number: 100000003334 5 / 9 Propylene glycol Industrial
Conditions to avoid
: Keep away from heat, flame, sparks and other ignition sources.
Exposure to light.
Incompatible materials
: Amines isocyanates mercaptans Reducing agents Strong oxidizing agents Acids Bases
Hazardous decomposition products
: Aldehydes Alcohols ethers Organic acids Carbon oxides toxic fumes
SECTION 11. TOXICOLOGICAL INFORMATION
Carcinogenicity
IARC
No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
OSHA
equal to 0.1% is identified as a carcinogen or potential carcino-gen by OSHA.
NTP
equal to 0.1% is identified as a known or anticipated carcinogen by NTP.
ACGIH
equal to 0.1% is identified as a carcinogen or potential carcino-gen by ACGIH.
Further information
Product:
Remarks: No data available
SDS Number: 100000003334 6 / 9 Propylene glycol Industrial
SECTION 12. ECOLOGICAL INFORMATION
Ecotoxicity
No data available
Persistence and degradability
No data available
Bioaccumulative potential
No data available
Mobility in soil
No data available
Other adverse effects
Product:
Ozone-Depletion Potential
: Regulation: 40 CFR Protection of Environment; Part 82 Pro-tection of Stratospheric Ozone - CAA Section 602 Class I Substances Remarks: This product neither contains, nor was manufac-tured with a Class I or Class II ODS as defined by the U.S.
Clean Air Act Section 602 (40 CFR 82, Subpt. A, App.A + B).
Additional ecological infor-mation
SECTION 13. DISPOSAL CONSIDERATIONS
Disposal methods
Waste from residues : Dispose of in accordance with all applicable local, state and federal regulations.
For assistance with your waste management needs - including disposal, recycling and waste stream reduction, contact NEXEO's Environmental Services Group at 800-637-7922.
Contaminated packaging : Empty containers should be taken to an approved waste han-dling site for recycling or disposal.
SECTION 14. TRANSPORT INFORMATION
DOT (Department of Transportation): Not regulated as a dangerous good
UNRTDG
Not regulated as a dangerous good
SDS Number: 100000003334 7 / 9 Propylene glycol Industrial
IATA (International Air Transport Association): Not regulated as a dangerous good
IMDG-Code: Not regulated as a dangerous good
SECTION 15. REGULATORY INFORMATION
WHMIS Classification
: : Not controlled.
EPCRA - Emergency Planning and Community Right-to-Know Act
CERCLA Reportable Quantity
This material does not contain any components with a CERCLA RQ.
SARA 304 Extremely Hazardous Substances Reportable Quantity
This material does not contain any components with a section 304 EHS RQ.
SARA 311/312 Hazards
: No SARA Hazards
SARA 302
: No chemicals in this material are subject to the reporting re-quirements of SARA Title III, Section 302.
SARA 313
: This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
Clean Air Act
This product does not contain any hazardous air pollutants (HAP), as defined by the U.S. Clean Air Act Sec-tion 12 (40 CFR 61).
This product does not contain any chemicals listed under the U.S. Clean Air Act Section 112(r) for Accidental Release Prevention (40 CFR 68.130, Subpart F).
The following chemical(s) are listed under the U.S. Clean Air Act Section 111 SOCMI Intermediate or Final VOC's (40 CFR 60.489):
57-55-6 Propylene glycol
Clean Water Act
This product does not contain any Hazardous Substances listed under the U.S. CleanWater Act, Section 311, Table 116.4A.
This product does not contain any Hazardous Chemicals listed under the U.S. CleanWater Act, Section 311, Table 117.3.
This product does not contain any toxic pollutants listed under the U.S. Clean Water Act Section 307
US State Regulations
Massachusetts Right To Know
No components are subject to the Massachusetts Right to Know Act.
Pennsylvania Right To Know
57-55-6 Propylene glycol 90 - 100 %
New Jersey Right To Know
57-55-6 Propylene glycol 90 - 100 %
SDS Number: 100000003334 8 / 9 Propylene glycol Industrial
California Prop 65 This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other re-productive harm.
The components of this product are reported in the following inventories:
TSCA
: On TSCA Inventory
DSL
: All components of this product are on the Canadian DSL
AICS
: On the inventory, or in compliance with the inventory
NZIoC
ENCS
KECI
PHIL
IECSC
SECTION16. OTHER INFORMATION
NFPA: HMIS III:
The information accumulated is based on the data of which we are aware and is believed to be correct as of the date hereof. Since this information may be applied under conditions beyond our control and with which we may be unfamiliar and since data made become available subsequently to the date hereof, we do not assume any responsibility for the results of its use. Recipients are advised to confirm in advance of need that the information is current, applicable, and suitable to their circumstances. This MSDS has been prepared by NEXEO™ Solutions EHS Product Safety Department (1-855-429-2661) MSDS@nexeosolutions.com.
Revision Date
: 04/03/2017
Legacy SDS:
: R0001099
Flammability
H e a lt h
In s ta b ility
FLAMMABILITY
PHYSICAL HAZARD
HEALTH
Special hazard.
0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 =Extreme, * = Chronic
SDS Number: 100000003334 9 / 9 Propylene glycol Industrial
Material number:
16117093, 16098634, 16056587, 16063761, 16056593, 16056591, 16056590, 16056589, 16056588, 16043949, 16022504, 16019678, 16007436, 16004870, 16004164, 16003701, 16002316, 732692, 708878, 707122, 706609, 686369, 684080, 670322, 652122, 643524, 643523, 643513, 587634, 541219, 508483, 103938, 54799, 54594, 87351, 56279, 103733, 89037, 58343, 104793, 54901, 105725, 72031, 87659, 89343, 89366, 55654, 87662, 105726, 105744, 89347, 56608, 72035, 87663, 158868, 173039, 504375, 500039, 500083, 29993, 29992, 20248, 20247, 20246
Key or legend to abbreviations and acronyms used in the safety data sheet
ACGIH American Conference of Gov-ernment Industrial Hygienists
LD50 Lethal Dose 50%
AICS Australia, Inventory of Chemical Substances
LOAEL Lowest Observed Adverse Effect Level
DSL Canada, Domestic Substances List
NFPA National Fire Protection Agency
NDSL Canada, Non-Domestic Sub-stances List
NIOSH National Institute for Occupational Safety & Health
CNS Central Nervous System NTP National Toxicology Program
CAS Chemical Abstract Service NZloC New Zealand Inventory of Chemicals
EC50 Effective Concentration NOAEL No Observable Adverse Effect Level
EC50 Effective Concentration 50% NOEC No Observed Effect Concentration
EGEST EOSCA Generic Exposure Sce-nario Tool
OSHA Occupational Safety & Health Administra-tion
EOSCA European Oilfield Specialty Chemicals Association
PEL Permissible Exposure Limit
EINECS European Inventory of Existing Chemical Substances
PICCS Philippines Inventory of Commercial Chemical Substances
MAK Germany Maximum Concentra-tion Values
PRNT Presumed Not Toxic
GHS Globally Harmonized System RCRA Resource Conservation Recovery Act
>= Greater Than or Equal To STEL Short-term Exposure Limit
IC50 Inhibition Concentration 50% SARA Superfund Amendments and Reauthori-zation Act.
IARC International Agency for Research on Cancer
TLV Threshold Limit Value
IECSC Inventory of Existing Chemical Substances in China
TWA Time Weighted Average
ENCS Japan, Inventory of Existing and New Chemical Substances
TSCA Toxic Substance Control Act
KECI Korea, Existing Chemical Invento-ry
UVCB Unknown or Variable Composition, Com-plex Reaction Products, and Biological Materials
<= Less Than or Equal To WHMIS Workplace Hazardous Materials Infor-mation System
LC50 Lethal Concentration 50%
File details come from the government source that posted it. Updated .