TE__1_Range_Hoods.xlsx

XLSX spreadsheet 26 KB Posted

Attached to
Range Hood Cleaning and Inspection for Fort Stewart
Solicitation number
W9124M-17-T-0101
Issued by

About this file

Technical Exhibit 1

View the file

Other files

File Type Posted
Amendment_001.pdf PDF
TE__1_Range_Hoods_V3.xlsx XLSX spreadsheet
TE_2B_Range_Hood_Inspection_Report.xls XLS spreadsheet
W9124M-17-T-0101.pdf PDF
TE_4_Deliverables_V2.docx DOCX document
TE_2A_Fire_Suppression_Report.pdf PDF
TE_3_PRS.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Technical Exhibit #1

TECHNICAL EXHIBIT # 1
FORT STEWART
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression System TypeMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
207Dining Facility133 mos6 mos
8.5 X 4.5wet 3 galPuro chemPCL 30028358520162027
16.5 X 4.5wet 4.6 galPuro chemPCL 46028001220162027
26.0 X 4.5wet 3 galPuro chemPCL 30028360820082019
wet 3 galPuro chemPCL 30021531020152026
11.5 X 4.5wet 3 galPuro chemPCL 30027652320162027
512Dining Facility546 mos6 mos
5 X 7wet 3 galAnsulR102S06032120152026
5 X 7wet 3 galAnsulR102S10413720152026
5 X 7wet 3 galAnsulR102S06942820152026
5 X 7wet 3 galAnsulR102S10413120152026
5 X 7wet 3 galAnsulR102S10436320152026
4 X 15.5wet 3 galAnsulR102S10412720152026
4 X 15.5wet 3 galAnsulR102S07435220152026
4 X 15.5wet 3 galAnsulR102R37139720152026
4 X 15.5NONE
642Dining Facility446 mos6 mos
4 X 10wet 3 galAnsulR102S22318420082019
4 X 11
4 X 10wet 3 galAnsulR102S22318320082019
4 X 11
4 X 15.5wet 3 galAnsulR102S22317720082019
4 X 15.5
4 X 15.5wet 3 galAnsulR102S22317420082019
4 X 15.5
TECHNICAL EXHIBIT # 1
FORT STEWART
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression System TypeMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
726Dining Facility443 MOS6 MOS
16 X 4wet 3 galPuro chemPCL 30035295120072018
16 X 4wet 3 galPuro chemPCL 30025300920072018
wet 6 galPuro chemPCL 60034345520072018
16 X 4wet 3 galPuro chemPCL 30034346020072018
wet 6 galPuro chemPCL 60035688720152026
16 X 4
4 X 8wet 3 galPuro chemPCL 30035298120072018
4 X 8wet 3 galPuro chemPCL 30035301320072018
4 X 8wet 3 galPuro chemPCL 30035299220072018
4 X 8wet 3 galPuro chemPCL 30035298520072018
3003Dining Facility553 mos6 mos
5 X 7wet 1.5 galAnsulR10210183820062017
5 X 10NONE
5 X 10NONE
5 X 7wet 1.5 galAnsulR10210315720062017
5 X 4.5NONE
5 X 12wet 3 galAnsulR10210313220062017
5 X 12wet 3 galAnsulR10220082019
5 X 12wet 3 galAnsulR10210307520082019
5 X 12wet 3 galAnsulR10210071120062017
13 X 5NONE
8439Dining Facility653 mos6 mos
5 X 7NONE
5 X 7NONE
5 X 7NONE
TECHNICAL EXHIBIT # 1
FORT STEWART
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression System TypeMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
84395 X 5wet 3 galAnsulR10215403920112022
5 X 5wet 3 galAnsulR10215404220112022
5 X 5wet 3 galAnsulR10215403520112022
10 X 5NONE
11 X 5NONE
11 X 5NONE
28 X 5wet 3 galAnsulR10215404420112022
28 X 5wet 3 galAnsulR10215404320112022
19225Dining Facility223 mos6 mos
4 X 4.5wet 3 galAnsulR102R50394020072018
4.5 X 5.5
17.5 X 4.75wet 3 galAnsulR102R50394320072018
17.5 X 4.75
19104Dining Facility46 mos6 mos
4.5 X 10wet 3 galAnsulR10220102021
4.5 X 10wet 3 galAnsulR10220102021
4.5 X 10wet 3 galAnsulR10220102021
4.5 X 10NONE

4.5 X 5.5 wet 3 gal Ansul R102 2010 2021

4.5 X 5.5 wet 3 gal Ansul R102 2010 2021

455Burger King24 wks6 mos
4 X 4wet 3 galAnsulR102S10857920142025
3 X 7wet 3 galAnsulR102S21953320142025
TECHNICAL EXHIBIT # 1
FORT STEWART
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression System TypeMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
703Popeye's24 wks6 mos
5 X 3wet 3 galAnsulR102S13551920162027
5 X 3wet 3 galAnsulR102S13551020162027
71PX64 wks6 mos
Arbys5 X 4wet 3 galAnsulR10215024320142025
Charleys5 X 4wet 3 galPyro chemPCL 30018016320142025
5 X 2NONE
Taco johns5 X 4wet 3 galPyro chemPCL 30018018420142025
4 X10NONE

Anthony's 2 X 3

419Marco's16 mos6 mos
8 x 8wet 3 galAnsulR10214300020142025
402Marne Lanes13 mos6 mos
14 x 5.5wet 4.6 galPuro ChemPCL 46023879720152026
450Stewart Lanes13 mos6 mos
15 x 5.5wet 3 galAnsulR10212853820092020
405Club Stewart23 mos6 mos
12 x 4.5wet 3 galAnsulR10220112022
12 x 4.5wet 3 galAnsulR10220112022
12 x 4.5wet 3 galAnsulR10220112022
12 x 4.5wet 3 galAnsulR10220112022
TECHNICAL EXHIBIT # 1
FORT STEWART
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression System TypeMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
40512 x 4.5wet 3 galAnsulR10220112022
12 x 4.5wet 3 galAnsulR10220112022
403CDC16 mos6 mos
6 x 4wet 3 galPuro chemPCL 30027651520162027
475CDC16 mos6 mos
10 x 4wet 3 galAnsulR10222277620082019
5500CDC16 mos6 mos
4.5 x 7wet 1.5 galAnsulR102S26975420132024
5655Youth center16 mos6 mos
8.5 x 4.5wet 3 galAnsulR10220112022
7100CDC16 mos6 mos
4 x 7wet 1.5 galAnsulR102S26869120132024
7160Youth Center16 mos6 mos
5.5 x 7wet 3 galAnsulR1022010102834720102021
TECHNICAL EXHIBIT # 1
HAAF
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression SystemMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
110Dining Facility323 mos6 mos
9.5 x 4.5wet 3 galPyro chemPCL 30016683220142025
4.5 x 5.5wet 3 galPyro chemPCL 30019326320142025
4 x 7wet 3 galPuro chemPCL 300
30.5 x 4.5wet 4.6 galPuro chemPCL 46015784020132024
30.5 x 4.5wet 4.6 galPyro chemPCL 46016587820142025
931Popeye's14 wks6 mos
12 x 3wet 3 galAnsulR102S11772320162027
6020Burger King24 wks6 mos
7 x 3wet 3 galAnsulR1025196620142025
4 x 4wet 3 galAnsulR1026982620142025
6020Noble Romans16 mos0 mos
4 x 5NONE
148CDC16 mos6 mos
4.5 x 7wet 1.5 galAnsulR 10228457720092020
1284CDC16 mos6 mos
4 x 8wet 3 galAnsulR 10234690520102021
3.5 x 6NONE
8805CDC16 mos6 mos
4.5 x 8wet 3 galAnsulR10220558720082019
TECHNICAL EXHIBIT # 1
HAAF
BuildingDescriptionSmallMediumDue Date Next CleaningDue Date Next InspectionFrequency Interval for CleaningFrequency Interval for InspectionFire Suppression SystemMFGModelSer. No.Last hydro testNo. of NozzlesDue hydro test
8807CDC16 mos6 mos
4.5 x 8wet 3 galAnsulR102s26451920102021
6054Youth Center26 mos6 mos
2 x 4wet 1.5 galAnsulR102s30596620102021
5 x 7wet 3 galAnsulR1022010123360520102021
HAAFCURRENTLY CLOSED ,OPTION TO REOPEN
1280Bowling Alley13 MOS6 MOS
5 x 16wet 3 galAnsulR 10212672220092020
This is a list of the buildings with range hoods and their approximate sizes.
Small hood should be anything with an opening between 1 and 50 square feet.
Medium should be anything with an opening between 51 and 250 square feet
Bldg 405 has 2 hood systems; each system contains 3 hood sections and each set of 3 sharing 1duct.
Bldg 19104 has 4 hood systems; 2 systems contains 2 hood sections and each set of 2 sharing 1duct. In addition to 2 single section hoods

Technical Exhibit 1 Page &P

File details come from the government source that posted it. Updated .