WASHER/DRYER SPECIFICATIONS
1.1. WASHERS
1.1.1. All washers shall be electric, 110 volts, coinless, heavy duty, commercial grade, and vertical axis that meet Department of Energy (DOE) Energy Star compliance, with a MINIMUM of 2.8 cubic foot capacity, Underwriters Laboratory (U.L.) listed and approved or equivalent.
1.1.2. Washers shall have a cycle selector has, as a minimum, a “Wash” and “Spin.”
1.1.3. Washers shall have all new hot and cold water and drainage hoses.
1.1.4. Water temperature selector has, as a minimum, “Hot”, “Warm”, and “Cold.”
1.1.5. Spin cycle shall be a minimum Revolutions Per Minute (RPM) of 710.
1.2. Washers for building 240, Warrior Transition Unit (WTU) shall be Americans with Disabilities Act (ADA) Compliant, shall have controls on the front and shall meet all requirements as listed in Para 1.1.1 through 1.1.5.
2.1 DRYERS, 220 volts
2.1.1. All dryers shall be coinless, heavy duty, commercial dryer, with an 18-pound minimum capacity, to include providing appropriate manufacturer suggested pronged cord to fit existing outlets, or appropriate gas fittings. Adapters shall not be used.
2.1.2. All Dryer vent hoses shall be made of flexible aluminum or resilient foil type material and clamps from machine to existing wall vent that fits in accordance with manufacturer standards and are not altered to fit.
2.1.3. Timing device selector on dryer shall be so that the user may preset dryer time as required, with automatic shut-off.
2.1.4. Selector shall have heat settings for durable press, normal and delicate fabrics, at a minimum.
2.1.5. Removable lint screen.
2.2. Buildings requiring stacked gas dryers are included in Technical Exhibit 3. Manual Control Double-stacked gas dryers shall meet the following dimensions in addition to the requirements at 2.1.1. through 2.1.5.: Width x Depth x Height of 26 7/8”W x 28” D x 75 ¼” H; electrical requirements of 120/60/1-15 amp and heating element – 25,000 BTU.
2.3. Dryers for building 240, WTU, shall be ADA compliant in addition to meeting all requirements listed in Para. 2.1.1. through 2.1.5.
2.3.1. ADA Dryers located in Building 240 (Rooms 201 and 302) are in a recessed location in the wall and must meet specific dimensions of Width x Depth x Height - 27” W x 30 5/16” D x 36”H.