Technical Specifications

• Purchase and install so that CCTV, Access Control and Duress Alarm equipment are tied into existing systems that are monitored and recorded within the MEPS.

• All systems must be stand-alone and separate of USMEPCOMs computer network and do not require internet access.

Access Control

- Three 6125 HID iCLASS RP40 multi CLASS card readers (brand name of equal) (tie into existing access control system)

- One set of magnetic locks or similar locking device (rated 600 lbs) used in conjunction with multi CLASS card reader

- One strobe light indicator (tie into existing stairwell door audible alarms)

- Remove existing request to exit sensor on main entry door

- Two door closers (to be installed on doors to rooms 302 and 307)

- One Aiphone J F-Series Master Station (brand name or equal)

- Two Aiphone JF-Series Sub-Master Stations (brand name or equal)

- One Aiphone JF-Series Door Station(brand name or equal)

CCTV

- Three interior low light, high resolution, color cameras, mini-domed, ceiling mounted (IR LEDs :=100', Color, 700TVL, 12VDC/24VAC, 4-9mm, IP65, White Housing) (tie into existing CCTV system)

- One 9 channel digital video recorder (DVR) w/CD-RW, 500GB -1TB hard drive (tie into existing CCTV system)

- One 40" color CCTV flat panel monitor with wall mounting hardware (tie into existing CCTV system)

- Two 32" color CCTV flat panel monitor (tie into existing CCTV system)

Duress Alarms

- One hard wired duress alarm switch (tie into existing duress alarm system)

• Install above equipment so it is powered through the UPS

• Provide all associated materials, tools and labor to complete work (cable, connectors, conduit, etc.) except what is listed under Government Supplied Materials o Government Supplied Materials: Blueprints and diagrams

• All exposed wiring must be incased in conduit, minimize use of conduit by installing wire in walls whenever possible.

Attachment 1, San Antonio MEPS SOW

A

B

C

D

E

F

G

H

Install the following at reference point A:

• One 6125 HID iCLASS RP40 multi CLASS card reader (similar to existing card readers) on outside of double doors for authorized personnel use (tie into existing access control system)

• One set of magnetic locks or similar locking device (rated 600 lbs) used in conjunction with multi CLASS card reader

Install the following at reference point B:

• One 6125 HID iCLASS RP40 multi CLASS card reader (similar to existing card readers) on outside of elevator doors for authorized personnel use (tie into existing access control system)

Install the following at reference point C:

• Remove existing request to exit sensor above main entry door ( existing sensor above door allows unauthorized entry when sensor is inadvertently triggered from inside of security vestibule) (use existing push bars for egress)

Install the following at reference point D:

• Install one fixed position duress alarm switch in a location within the security screener's immediate reach (tie into existing duress alarm system). Install the switch in a manner/location where it can be activated without others detecting the action

• One 32" color flat panel monitor for CCTV viewing (tie into existing CCTV system) on security screener's desk

• One Aiphone JF-Series Master Station on security screener's desk (tie into Aiphone JF-Series Door Station at main entry door (with release)

Install the following at reference point E:

• One interior low light, high resolution, color camera, mini-domed, ceiling mounted aiming South covering stairwell ( exact location TBD by MEPS personnel) tie into existing CCTV system

Install the following at reference point F:

• One interior low light, high resolution, color camera, mini-domed, ceiling mounted aiming West covering hallway (exact location TBD by MEPS personnel) (IR LEDs ::::::100', Color, 700TVL, 12VDC/24V AC, 4-9mm, IP65, White Housin!!:) (tie into existing CCTV system)

Install the following at reference point G:

• One 6125 HID iCLASS RP40 multi CLASS card reader (similar to existing card readers) on outside of elevator doors for authorized personnel use (tie into existing access control system)

Install the following at reference point H:

One light indicator tied into local audible alarm at stairwell #2 doors on 2nd and 3rd floor (light must flash for unauthorized egress at stairwell doors)

One 9 channel digital video recorder (DVR) w/CD-RW, 500GB-1 TB hard drive (tie into existing CCTV system) One Aiphone JF-Series Sub-Master Station (tie into Aiphone JF-Series Door Station at main entry door (with release) (replacement for existin� intercom)