Text version
Building R-2261 Fort Bragg, NC
Asbestos Survey for Renovation of
Fort Bragg, North Carolina
Prepared by Solomon Locklear of Carolina Environmental Design, LLC, Inspector
License Number 12601 for
The Directorate of Public Works, Ft. Bragg, North Carolina
Asbestos Survey Report
Introduction
Scope of the Investigation
This report documents the asbestos inspection and survey of the Building R-2261 located at Fort Bragg, North Carolina conducted on November 17th, 2015, and returned on March 1st, 2016 to take additional samples on the exterior of the building. The inspection was conducted by Solomon Locklear, NC asbestos inspector license number: NC12601.
Background
The building is constructed out of corrugated metal and transite panels on the exterior, with the windows of the building constructed out of metal. The window panes are held in place with window glazing and window caulk present on the outer edges of the windows. The roof system of the building is a flat roof system that has the rubber roof membrane, and there are pipes and miscellaneous equipment that are sealed with both white and black roof caulk. The interior of the building is constructed out of CMU block and drywall/joint compound and ceiling tile present in the ceiling. The flooring system is a concrete floor system covered with a layer of light orange 12”x12”floor tile with black mastic. In some areas, there is an additional layer of 12”x12” floor tile with mastic. The HVAC pipes running throughout the building were covered with fiberglass insulation.
Conclusions
Asbestos was detected in the following materials:
12”x12” Floor Tile With Black Mastic Window Caulking Transite Siding Material
Asbestos was not detected in the following materials:
Floor Tile With Yellow Glue Drywall/Joint Compound Acoustical Ceiling Tile Black Roof Caulk White Roof Caulk Window Glazing
Limitations
As is the case with any asbestos inspection, materials that were not readily apparent or were located in concealed locations may not have been identified. If any material that is suspected to contain asbestos, and was not included in this report as a material identified and tested, is discovered, it should be evaluated for asbestos content before it is disturbed.
This report is not intended for use as an asbestos removal specification. It is not within the scope of this work to describe all appropriate precautions, safeguards and regulations relating to asbestos.
Sole Use Statement
This report is provided for the sole use of the Directorate of Public Works at Ft. Bragg. Reliance on this report by any third parties will be at such party’s sole risk, and Carolina Environmental Designs the survey disclaims liability for any use of or reliance on this report by third parties. All portions of this report, including attachments and figures, are interrelated and integral to this report and should not be transmitted independent of each other.
Asbestos Containing Materials
MATERIAL CHARACTERISTICS ASSESSMENT
Sample Type Homogenous Area Description/Location
% Asbestos Yes/No/Presumed
Quantity/Type (If ACM)
Friable / Non-Friable Condition Disturbance
Potential
MISC
12”x12” Floor Tile With Black Mastic, Located in the Parachute Storage and Maintenance Area of the Hangar
5% Chrysotile
7,500 SF Non-Friable Good Low
MISC
Window Caulking Located on the
Exterior/Interior of Building Around the Edges of the Window
10% Chrysotile
Unable to Quantify Non-Friable Good Low
MISC
Transite Siding Material, Located on the Exterior Walls of Building and interior Bay Walls
15% Chrysotile 7,150 SF Non-Friable Good Low
Laboratory Reports and Chain of Custody Forms
Sample Locations
Pictures of Asbestos Containing Materials
Window Caulking Present on Exterior and Interior of Building
Red 12”x12” Floor Tile with Black Mastic
Exterior Transite Siding
Interior Transite Siding on Bay Upper Walls
Certifications and Accreditations
FB Form 4283
| Asbestos Survey for Renovation of |
| Building R-2261 |
| Fort Bragg, North Carolina |
| Introduction |
| Scope of the Investigation |
| Background |
| Conclusions |
| Limitations |
| Sole Use Statement |
| Asbestos Containing Materials |
| Laboratory Reports and Chain of Custody Forms |
| Sample Locations |
File details come from the government source that posted it. Updated .