This is a pre-proposal conference presentation for the Plating Shop Renovation project at Hill Air Force Base, Utah. The project involves a comprehensive renovation of Buildings 505 and 507, with a total estimated construction value between $100-250 million. The solicitation (W9123825RA003) is an unrestricted, firm-fixed-price design-bid-build contract with a 1,825 calendar day performance period, phased into four distinct stages of demolition and new construction of plating process lines.
Key project details include replacing multiple plating process lines, updating electrical and ventilation systems, modifying roof equipment, and constructing a 2,800 sq ft pre-engineered metal building. The evaluation will use a Best Value Tradeoff methodology, with non-price factors weighted more heavily than cost. Small business participation goals include 30% total small business involvement, with specific targets for small disadvantaged businesses (14%), women-owned small businesses (7%), HUBZone businesses (5%), and service-disabled veteran-owned businesses (5%). Proposals are due 17 March 2025, with an estimated award date of 30 June 2025.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Please sign in.
PLATING SHOP RENOVATION
PRE-PROPOSAL CONFERENCE AND
SITE VISIT
W9123824R0032/
W9123825RA003
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
9:00 AM Welcome & Introductions
Safety Information
9:05 AM Administrative Announcements
Pre-Proposal Conference Objective
Project / Site Visit Objective
Major Project Milestones
How to obtain the Solicitation & Submit Proposals
9:25 AM Procurement Overview
9:35 AM Construction Contract Administration
9:45 AM Closing Remarks / Invitation to Site Visit
10:00 AM Site Visit (PPE)
AGENDA
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
3WELCOME AND INTRODUCTIONS
United States Army Corps of Engineers (USACE) Sacramento District (SPK) Mr. Lee Roach Project Manager Mr. Tom Stonehocker Technical Lead Ms. Amy Bryant Contracting Officer Ms. Aurielle Ruiz Contract Specialist Ms. Kirstin Hiortdahl Asst. Resident Engineer Mr. Dave Smeraldo Chief Construction Inspection
Hill AFB – 309th CMXG (Commodities Maintenance Group) Mr. Matthew Mikkelsen Metal Build Engineering, AFMC/CMXG Ms. Glenda Rhodes Metal Build Engineering, AFMC/CMXG
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
4SAFETY INFORMATION
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Presenter Notes Presentation Notes Provide logistics information (e.g.,the location of restrooms and emergency exits, any building regulations, etc.)
During the Conference:
• Please silence all cell phones
• Please submit all questions through ProjNet
During the Site Visit:
• No audio/video recordings
• No photos By request, Site Photos will be taken by a Gov’t representative and posted on ProjNet.
• Please remain with Government escorts
ADMINISTRATIVE ANNOUNCEMENTS
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Informal Presentation and Site Visit o Provide interested parties with a clear understanding of the solicitation requirement o Provide procurement timelines to facilitate value-added questions and answers (Q&A) from industry o Provide an opportunity for interaction between prime contractors and sub-contractors o Allow offerors with opportunity to familiarize themselves with the project site and formulate questions o All questions and correspondence shall be submitted via ProjNet
After today:
o Bidder inquiries can be made through 13 March 2025 o Todays briefing and Sign-In Sheet and presentation will be posted on the System for Award Management (SAM) – www.sam.gov.
PRE-PROPOSAL CONFERENCE / SITE VISIT
OBJECTIVE
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
7MAJOR PROJECT MILESTONES
Draft RFP , Plans & Spec 20 March 2024
Industry Day 17 April 2025
Pre-solicitation Notice 21 Sept 2025 (W9123824R0032)
RFP 13 Feb 2025 (W9123825RA003)
ProjNet Opened 13 Feb 2025
Site Visit 6 March 2025
ProjNet Closes 13 March 2025
Proposals Due 17 March 2025
Award 30 June 2025 (estimated)
Construction Period 1825 calendar days
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
We are Here
• Procurement Integrated Enterprise Environment (PIEE) – https://piee.eb.mil/
• Solicitation Number: W9123825RA003
• Requirements to download Technical Data Package:
1) Need to be registered in System for Award Management (SAM) – www.sam.gov
2) Need to be registered in PIEE
• Register to receive notifications and updates/amendments
• Request for Proposals (RFP) technical information will be posted on the PIEE website
HOW TO OBTAIN THE SOLICITATION
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Presenter Notes Presentation Notes The solicitation, solicitation attachments, and amendments are posted on the Procurement Integrated Enterprise Environment (PIEE) website https://wawf.eb.mil OR https://piee.eb.mil OR https://piee.eb.mil/xhtml/unauth/home/login.xhtml with notification posted on the Government-wide Point of Entry, the System for Award Management (SAM- www.sam.gov/SAM).
https://piee.eb.mil/ http://www.sam.gov/
Plating Shop Renovation, Hill AFB, Utah
North American Industry Classification (NAICS) Code: 236210, Industrial Building Construction
Small Business Administration (SBA) Size Standard: $45,000,000.00 Annual Revenue
Estimated Magnitude of Construction: $100,000,000 And $250,000,000.
Project is Design-Bid-Build (DBB) Design prepared by Burns & McDonnell
Unrestricted (full and open), Firm Fixed Price
Source Selection Methodology, Best Value Tradeoff (BVTO): All non-price evaluation factors, when combined, are MORE IMPORTANT than cost or price. The government will evaluate the total price for all options and the total price for the basic requirement
One (1) Firm Fixed Priced, C-Type Contract will be awarded under this solicitation
PROCUREMENT OVERVIEW
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
CLIN PHASE DESCRIPTION CALENDAR DAYS AFTER NOTICE TO
PROCEED
One
Demolition of existing 'A' tank line (BLDG 507); Removal of internal center ovens and exterior ovens (BLDG 505).
456 (estimated) for phase one both CLINS 0001 and 0002
0002 Installation of new Type II Anodize tank line (BLDG 507)
Two
Demolition of existing Chrome, Type II Anodize, Type III Anodize, and Phosphate/Passivate tank lines. (BLDG 505)
456 (estimated) for phase two both CLINS 0003 and
0004 Installation of new Type II Anodize tank line (BLDG 507); Install new Chrome, Type III Anodize, and Phosphate/Passivate tank lines (BLDG 505).
Three
Demolition of existing Cadmium Plating, Cadmium Iridate, Zinc Nickel, Temper, Etch, Nickel and Electroless Nickel tank lines (BLDG 505)
456 (estimated) for phase three both CLINS 0005 and
0006 Installation of new Chrome Strip, FPI, Future and Degrease tank lines. (BLDG 505)
Four
Demolition of existing Chrome and FPI tank lines (BLDG 505) 456 (estimated) for phase four both CLINS 0007 and
0008 Installation of new Chrome tank line. (BLDG 505)
Optional 1001 N/A Contaminated Soil Removal ( Estimated Qty) Exercised at award or within 365 calendar days of NTP for Phase One
Optional 1002 N/A Chemical Addition System (lump sum) will be correct by amendment Exercised at award or within 365 calendar days of NTP for Phase One
CONTRACT LINE ITEMS (CLINS)
• A Notice-to-Proceed (NTP) will be issued for each phase of construction.
• All phases of work shall be completed with 1,825 calendar days from issuance of the NTP for Phase One
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Federal Acquisition Regulation (FAR) Clause 52.211-10 Commencement, Prosecution, and Completion of Work. (Apr 1984)
Offeror will propose durations for each phase of construction that accommodate the unique construction activities of each phase, within the 1,825-day overall project period-of-performance. The successful proposal's schedule will be accepted as the contracted periods-of-performance for each Phase.
The Contractor shall be required to (a) commence work under this contract within ten (10) calendar days after the date the Contractor receives the notice to proceed, (b) prosecute the work diligently, and (c) complete the entire work ready for use no later than 1,825 calendar days.
FAR clause 52.211-12 Liquidated Damages-Construction. (Sep 2000)
If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of $2,490.00 for each calendar day of delay for each Phase until the work for that Phase is completed or accepted.
If the Government terminates the Contractor's right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.
PERIOD OF PERFORMANCE
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
FACTOR DESCRIPTION RELATIVE IMPORTANCE
1 Past Performance Most important factor
2 Technical Narrative Less important than Factor 1 but more important than Factor 3
3 Network Analysis Schedule (NAS) Less important than Factor 2 but more important than Factor 4
4 Organization, Management, and Quality Control Less important than Factor 3 but more important than Factor 5
5 Small Business Participation Commitment Document
Less important than Factor 4 but more important than Factor 3
EVALUATION FACTORS
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
All non-price evaluation factors, when combined, are MORE IMPORTANT than cost or price
FACTOR OVERVIEW
Past Performance: The Offeror should submit no more than five (5) projects similar in project size, scope, and complexity to this project to be performed.
Recency: Substantially completed within the last ten (10) years of the original date of issuance of this RFP
Relevant Experience
• Scope – Demolition/Partial Demolition and New construction or renovation of ten thousand (10,000) square feet (SF) or larger building
• Magnitude – $25,000,000 or larger
• Complexity – New Construction and/or renovation of facilities with linear manufacturing lines and/or specialized parts fabrication and assembly; demolition and Hazardous, Toxic and Radioactive Waste (HTRW) abatement; working in an operational facility
FACTOR - 1 PAST PERFORMANCE
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
FACTOR 2 - TECHNICAL NARRATIVE
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
a. The Offeror provides a technical narrative in sufficient detail to clearly demonstrate the Offeror’s understanding of the principal components of work described in the project specifications and drawings and the Offeror’s understanding of the site and other conditions that could impact schedule. The narrative must contain sufficient information to allow the Government to perform a basic analysis of the proposed design and construction approach.
b. The technical narrative should describe how the Offeror will approach the construction of the project. The Government is interested in information such as: security requirements; phased demolition and construction of specific process line areas;
coordination with ongoing facility operations during construction; coordination with USACE and AF quality assurance and quality control assurance, safety management, demolition, hazardous materials abatement, and working in an operational facility and clean- up.
c. The Offeror’s technical narrative should also describe any significant challenges anticipated in performing or accomplishing the work of this project, lessons learned from similar projects that could be applied to the challenges of this project, and the Offeror’s plan for mitigating risks which could adversely impact project schedule.
• Assume an arbitrary estimated, non-binding NTP of 30 June 2025, and assume award of the base and all option
• This summary schedule will, after contract award, be replaced with a project schedule as required by Section 01 32 01.00 10:
Project Schedule.
• Offeror will provide durations for each Phase of construction that accommodate the unique construction activities of each phase, within the 1825-day overall project period-of-performance.
• The successful offerors proposal’s schedule will be accepted as the contracted periods-of-performance for each Phase.
• Each Phase will receive NTP based on successful completion of all previous Phase activities.
• Should the Offeror discover during proposal preparation that the project cannot be completed within the required contract performance period; the contractor shall notify the KO immediately
FACTOR 3 - NETWORK ANALYSIS SCHEDULE
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Element A - Project Organization Chart
Provide an organizational chart at minimum, graphically depicts the Offeror’s proposed project team, to include “key” major work elements etc.
Element B - Management Plan
Provide a comprehensive Management Plan specifically developed for implementation for this project. Discuss the management approach used to plan, organize, direct, control, and staff the construction and closeout.
Element C - Approach to Quality Control
Provide a comprehensive Quality Control procedure specifically developed for implementation of this project. Provide a detailed narrative discussion of the Offeror’s plan for ensuring quality control during the construction of this project.
FACTOR 4 - ORGANIZATION, MANAGEMENT, AND
QUALITY CONTROL
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
All Offerors (both large and small business) will be evaluated on the level of proposed participation of U.S. small businesses in the performance of acquisition (as small business prime Offerors or small business subcontractors) relative to the objectives and goals established herein. The Government will evaluate:
Small Business: 30% of the total contract value;
Small Disadvantaged Business (SBD) 14% of the total contract value, Woman-Owned Small Business (WOSB): 7% of the total contract value, Historically Underutilized Business Zone (HUBZone) Small Business: 5% of the total contract value of the total contract value, Service-Disabled Veteran Owned Small Business (SDVOSB): 5% of the total contract value.
FACTOR - 5 SMALL BUSINESS PARTICIPATION
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Presenter Notes
Ability to meet or exceed these goals
The Government will evaluate all aspects of the price proposal for fairness and reasonableness. Price will not be an adjectivally rated criterion, but will be evaluated as to reasonableness and realism, and for providing the best value to the Government.
A price analysis will be performed on the total proposed price for the project. This includes all base CLINS and all option CLINS IAW FAR 52.217-5. The price will be evaluated for completeness and reasonableness as follows:
Completeness – To be complete, the Offeror must provide all data that is requested and necessary to evaluate the price. The Government will assess the extent to which the proposed prices comply with content and format requirements set forth in this solicitation.
Reasonableness – The Offeror’s proposal is evaluated through price analysis techniques as described in FAR 15.305(a)(1) and FAR 15.404-1(b). For price to be reasonable, it must represent a price that represent provides value to the Government when consideration is given to prices in the market, (market conditions may be evidenced by other competitive proposals), and technical and functional capabilities of the Offeror.
PRICE ANALYSIS
SUBMISSION REQUIREMENTS
Volume I – TECHNICAL PROPOSAL
VOLUME II – PRICE PROPOSAL
CONTENTS OF THE PRICE PROPOSAL
1 Proposal Covert Sheet
2 SF 1442; Acknowledgement of Amendments; JV Agreement
3 Pricing Schedule
4 Work Breakdown Structure
5 Representations, Certifications, and Other Statements of Offerors
6 Bid Guarantee
7 Pre-Award Survey Information
8 Subcontracting Plan (Other than Small)
CONTENTS OF THE TECHNICAL PROPOSAL
TAB FACTOR CONTENTS OF THE TECHNICAL PROPOSAL
N/A Preface
1 Factor 1 Past Performance
2 Factor 2 Technical Narrative
3 Factor 3 Network Analysis Schedule (NAS)
4 Factor 4 Organization, Management, and Quality Control
5 Factor 5 Small Business Participation Commitment
• The Government will NOT accept Offerors submitted in hard copy, by telegraph, or by facsimile.
• All prospective Offerors and their Subcontractors must be registered SAM – (www.SAM.gov) and the PIEE website to be able to view and download solicitation information, and to submit offers.
• Offers MUST BE submitted electronically through the PIEE website.
• Registration should be completed one (1) week prior to the anticipated solicitation release date.
• USACE will NOT notify Offerors of any changes to the solicitation; Offerors must monitor PIEE and SAM for the solicitation to be posted, and for any posted changes or amendments.
• Submissions shall be in Adobe PDF format.
• Only one (1) submission is allowed per Offeror.
SUBMITTING OFFERS
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Presenter Notes Presentation Notes The solicitation, solicitation attachments, and amendments are posted on the Procurement Integrated Enterprise Environment (PIEE) website https://wawf.eb.mil OR https://piee.eb.mil OR https://piee.eb.mil/xhtml/unauth/home/login.xhtml with notification posted on the Government-wide Point of Entry, the System for Award Management (SAM- www.sam.gov/SAM).
http://www.sam.gov/
• Safety first – following the USACE Safety Manual while developing a quality product for HAFB, UT
• Engineering Manual 385-1-1
• Dedicated USACE Resident Office in Utah
• Key staff co-located at HAFB, UT
• USACE Resident Management System (RMS) will be used
• Monthly schedule (Primavera) updates required
• Monthly progress payments
• Government is committed to partnering process at all levels
CONSTRUCTION CONTRACT ADMINISTRATION
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Renovation of the HAFB plating processes facility includes repair and renovation of existing structure (B505) and new construction:
• Plating tanks with columns, framing, grating and surrounding operating floor will be replaced.
• Roof structure will be modified to provide crane support; roof exhaust fans will be replaced.
• Floor will be repaired to provide support of new tanks.
• Chemical resistant coatings on the floor, walls, and ceilings will be refurbished.
• Ventilation will be updated for the chemical process.
• Tank plumbing will be connected to Industrial Waste Treatment Plant (IWTP) lines.
• Electrical system will be updated for busways, feeders, panelboards, circuits, receptacles, controls, etc.
• Lighting will be revised, and new lights added for adjusted plating process.
• Fire suppression system will be updated for plating processing changes.
• Eyewash stations and other required life safety systems will be provided.
A 2,800 SQ FT Pre-Engineered metal building (PEMB) will be constructed for existing ovens that protrude from the side of B505. The PEMB will include basement, operating floor, equipment platforms and steel stairs. The PEMB construction includes insulated steel metal panels, a standing seam metal roof, polyisocyanurate insulation, gutters, downspouts, and snow guards.
The PEMB will be located for access from B505, and an expansion joint will be placed between the PEMB and B505.
PROJECT OVERVIEW
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Presenter Notes
Renovation of the HAFB plating processes facility includes repair and renovation of existing structure (B505) and new construction. The existing B505 structure consists of reinforced concrete footings, reinforced concrete basement slabs, concrete masonry unit (CMU) walls supporting structural steel framing for tanks, operating floor, aisleways, bridge cranes, roof, and heating and ventilation air condition equipment on the roof. The plating tanks with columns, framing, and grating and most of the surrounding operating floor will be replaced. The roof structure will be modified to provide proper crane support. The floor will be repaired to provide support of new tanks. The chemical resistant coatings on the floor, walls, and ceilings will be refurbished. The ventilation will be updated for the chemical process. Government furnished equipment (GFE) tanks with necessary support equipment will be replaced. Tank plumbing will be connected to Industrial Waste Treatment Plant (IWTP) lines. The electrical system will be updated for busways, feeders, panelboards, circuits, receptacles, instrumentation and controls and other components that need updated. B505 lighting will be revised, and new lights added for adjusted plating process. The fire suppression system will be updated for plating processing changes. Eyewash stations and other required life safety systems will be provided. A Pre-Engineered metal building (PEMB) will be constructed for existing ovens that need to protrude from the side of B505. The PEMB will be approximately 2,800-square-feet with basement, operating floor, equipment platforms and steel stairs. The PEMB construction includes insulated steel metal panels, a standing seam metal roof, polyisocyanurate insulation, gutters, downspouts, and snow guards. The PEMB will be located for access from B505. An expansion joint will be placed between the new PEMB and B505.
Plating Shop Pre-Proposal Conference and Site Visit
PROJECT OVERVIEW
This presentation is for informational purposes only and is not and will not be contractually binding
N
Project Location and Vicinity
Plating Shop Renovation Building 505 Hill AFB, Utah
Presenter Notes
Orient to map; north and South Gate entrance to HAFB
This presentation is for informational purposes only and is not and will not be contractually binding
PROJECT OVERVIEW
N
25PROJECT OVERVIEW
This presentation is for informational purposes only and is not and will not be contractually binding
Building 505 (B505) Scope of Work Renovation Footprint
Pre-Engineered Metal Building (New Construction)
26PROJECT OVERVIEW
This presentation is for informational purposes only and is not and will not be contractually binding
Existing Plating Process Lines in B505
• PROJECT IS PHASED TO ENSURE CONTINUOUS, ONGOING PLATING SHOP
OPERATIONS.
• ALL ACTIVE PHASE WORK MUST BE COMPLETED, TESTED, AND APPROVED BEFORE
MOVING ON TO SUBSEQUENT PHASES.
• ACTIVE WORK MUST NOT CONTAMINATE ANY PREVIOUS OR SUBSEQUENT PHASES.
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Operating Floor – Phase 1 (B507)
Phase 1 - Demolition:
1. 507: Existing “A” tank line removed
2. 505: Existing internal center ovens removed
3. 505: Existing exterior ovens and metal buildings housing them removed
Phase 1 - New Work:
1. 507: Install new Type II Anodize line in previous “A” tank line area with tank-mounted scrubbers where needed (13 tanks)
2. 505: Install new Chrome line in previous center oven line area (6 tanks + 1 Anode pit)
3. 505: Install new Type III Anodize and Phosphate/passivate lines in altered exterior metal building
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Presenter Notes Presentation Notes Phase 1 Area of Work is highlighted
Phase 1 includes demolition and installation of PEMB at northwest corner of B505 (Drawings Vol 1, Elevations – Sheet A0207, Sections – A0307)
This presentation is for informational purposes only and is not and will not be contractually binding
PROJECT OVERVIEW
Operating Floor – Phase 1 (B505)
Phase 1 - Demolition:
1. 507: Existing “A” tank line removed
2. 505: Existing internal center ovens removed
3. 505: Existing exterior ovens and metal buildings housing them removed
Phase 1 - New Work:
1. 507: Install new Type II Anodize line in previous “A” tank line area with tank-mounted scrubbers where needed (13 tanks)
2. 505: Install new Chrome line in previous center oven line area (6 tanks + 1 Anode pit)
3. 505: Install new Type III Anodize and Phosphate/passivate lines in altered exterior metal building
Presenter Notes Presentation Notes Phase 1 Area of Work is highlighted
Phase 1 includes demolition and installation of PEMB at northwest corner of B505 (Drawings Vol 1, Elevations – Sheet A0207, Sections – A0307)
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
Operating Floor – Phase 2
Phase 2 - Demolition:
1. Existing Chrome lines removed (22 tanks + 1 Anode pit)
2. Existing Anodize Type II line removed (16 tanks)
3. Existing Anodize Type III line removed (23 tanks)
4. Existing Phosphate/Passivate line removed (10 tanks)
Phase 2 - New Work:
1. Install new Cadmium line located in previous Chrome line (6 tanks)
2. Install two new Zinc Nickel lines located where Chrome lines were previously (12 tanks)
3. Install new Temper Etch line located where Phosphate/Passivate lines were previously (6 tanks)
4. Install new Nickel and Electroless Nickel lines where Anodize lines were previously (26 tanks)
Presenter Notes
Phase 2 Area of Work is highlighted
This presentation is for informational purposes only and is not and will not be contractually binding
PROJECT OVERVIEW
Operating Floor – Phase 3
Phase 3 - Demolition:
1. Existing Zinc Nickel line removed (7 tanks)
2. Existing Cadmium Plating line removed (7 tanks)
3. Existing Cadmium Iridite line removed (4 tanks)
4. Existing Nickel and Electroless Nickel lines removed (30 tanks)
5. Existing Temper Etch line removed (7 tanks)
Phase 3 - New Work:
1. Install Chrome Strip line located where Cadmium Iridite line was previously installed (9 tanks)
2. Install FPI line located where Cadmium Plating line was previously installed (8 tanks)
3. Install Future line located where Electroless Nickel line was previously located (6 tanks)
4. Install Degrease line located where Nickel line was previously located (6 tanks)
Presenter Notes
Phase 3 Area of Work is highlighted
This presentation is for informational purposes only and is not and will not be contractually binding
PROJECT OVERVIEW
Operating Floor – Phase 4
Phase 4 - Demolition:
1. Existing Chrome Strip line removed (8 tanks)
2. Existing FPI line removed (8 tanks)
Phase 4 - New Work:
1. Install Chrome line installed where Chrome Strip was previously installed (5 tanks + work area)
Presenter Notes
Phase 4 Area of Work is highlighted
Roof
Roof construction activities will follow the phasing activities listed under the Operating Floor.
Roof equipment to be removed:
(2) Abandoned cooling towers
(2) Existing chrome exhaust fans Existing wax exhaust fan and ductwork
Roof Equipment to be added:
(2) New chrome exhaust fans New wax exhaust fan and ductwork
Basement construction activities NOT related to process line component replacement will follow the phasing activities listed under the Operating Floor.
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
34QUESTION AND ANSWERS
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
SITE WALK LOCATION
Parking is located adjacent to the Utah Resident Office (B367)
Attendees will be escorted across S Gate Dr via crosswalk to B505.
Gov’t Personnel will NOT answer questions during the Site Walk;
post all questions to ProjNet.
South Gate
URO
N
Plating Shop Pre-Proposal Conference and Site Visit This presentation is for informational purposes only and is not and will not be contractually binding
| Plating shop renovation �pre-proposal conference and�site visit��W9123824R0032/�W9123825RA003 |
| AGENDA |
| Welcome and introductions |
| Safety information |
| Administrative announcements |
| Pre-proposal Conference / Site Visit �objective |
| MAJOR PROJECT MILESTONES |
| HOW TO OBTAIN THE SOLICITATION� |
| procurement Overview |
| CONTRACT LINE ITEMS (CLINS) |
| PERIOD OF PERFORMANCE |
| Evaluation Factors� |
| Factor - 1 Past Performance |
| Factor 2 - TECHNIcAL Narrative |
| Factor 3 - Network Analysis Schedule� |
| �Factor 4 - Organization, Management, and Quality Control�� � |
| �Factor - 5 small business participation� |
| Price Analysis |
| SUBMISSION REQUIREMENTS |
| SUBMITTING OFFERS� |
| CONSTRUCTION CONTRACT ADMINISTRATION� |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| PROJECT OVERVIEW |
| Question and Answers |
| Site Walk Location |
File details come from the government source that posted it. Updated .