A01 Civil Demo Drawings Haul Route.pdf

PDF 3 MB Posted

Attached to
Hill Air Force Base, UT Storage Igloos Demolition
Solicitation number
W9123825QA030
Issued by

About this file

These are civil demolition drawings for the U.S. Army Corps of Engineers project at Hill Air Force Base, Utah, specifically targeting Buildings 1411 and 1432 (igloos). The documents include detailed demolition plans for two buildings, showing the precise locations of structures to be demolished, including existing pavement, underground electric utilities, and transformer locations. Key notes specify that the contractor must:

  1. Use designated access gates
  2. Determine exact staging area locations with the Contracting Officer
  3. Protect existing pavements and trees
  4. Manage temporary drainage, grading, erosion control, and utility connections
  5. Restore sites to original conditions upon completion

The demolition plans are dated 14 April 2023, prepared by the Sacramento District of the U.S. Army Corps of Engineers, and cover approximately 1 acre of staging area with specific instructions for utility protection and site restoration.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 1: Civil Demolition Drawings/ Construction Haul Route

ENGINE

C O

TT

O

N W

O O

D S

T.

ROY GATE

SO

U

TH

G

ATE R

D

SOUTH GATE

PROJECT SITE HAUL ROUTE

GEORGIA ST

APPROXIMATE STAGING AREA (1 AC)

ALABAMA ST

SE

R

VI

C

E

M

AP

LE

BEECHNUT

NOTES:

1. CONTRACTOR ACCESS WILL BE THROUGH DESIGNATED GATE AS SHOWN

ON PLANS.

2. LOCATION OF THE CONTRACTOR STAGING AREAS SHOWN is

APPROXIMATE. THE EXACT LOCATIONS WILL BE DETERMINED IN THE

FIELD BY THE CONTRACTING OFFICER.

3. NO BLADES OR BUCKETS SHALL BE ALLOWED TO CONTACT EXISTING

PAVEMENTS THAT ARE TO REMAIN. ONLY POWER SWEEPERS SHALL BE

ALLOWED TO REMOVE DEBRIS FORM THE SURFACE OF PAVEMENTS TO

REMAIN.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY DRAINAGE,

GRADING, EROSION CONTROL, STABILIZATION, AND UTILITY

CONNECTIONS IN STAGING AREAS AND SHALL RESTORE SITE TO

ORIGINAL CONDITIONS UPON COMPLETION.

5. ALL CONSTRUCTION AREAS SHALL BE CONSIDERED LAND DISTURBANCE

AREAS.

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

D R

AF

T

SU

BM

IT

TA

L

H

IL

L

AI

R F

O R

C E

BA

SE

, U

TA

H B1

AN

D

IG

LO

O

D

EM

O

LI

TI

O

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

A

PR

AN

SI

D

S.

M

IT

C

H

EL

L

S.

M

IT

C

H

EL

L

L.

N

EM

ET

Z

S.

M

IT

C

H

EL

L

G-001

H

AU

L R

O U

TE

A

N D

S

TA

G

IN

G A

R

EA

DEMOLISH BUILDING 1411

DEMOLISH

EXISTING

PAVEMENT

PROTECT TREES

IN-PLACE

W W W W W W W W W W W W

W W W W W W W W W W W W W W W W W W W W W W W

WWWWWWWWWWWWWWWWWWWWWWWW

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W

E E E E E E E E

E E E E E E E E E E E E E E E E E E

E E

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

DEMOLISH EXISTING UNDERGROUND

ELECTRIC FROM IGLOO TO TRANSFORMER

PROTECT IN PLACE

NOTES:

1. SEE PERFORMANCE WORK STATEMENT (PWS) FOR

DEMOLITION DETAILS..

2. SEE BUILDING DESCRIPTION(S), PWS 3.0 DETAILED

DESCRIPTION OF SERVICES.

3. UTILITY LOCATIONS ARE APPROXIMATE.

CONTRACTOR WILL FIELD VERIFY LOCATIONS PRIOR

TO DEMOLITION.

4. PROTECT IN PLACE ALL EXISTING UTILITIES UNLESS

OTHERWISE NOTED.

BUILDING 1411 DEMOLITION PLAN

1"=30'

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

D R

AF

T

SU

BM

IT

TA

L

H

IL

L

AI

R F

O R

C E

BA

SE

, U

TA

H B1

AN

D

IG

LO

O

D

EM

O

LI

TI

O

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

A

PR

AN

SI

D

S.

M

IT

C

H

EL

L

S.

M

IT

C

H

EL

L

L.

N

EM

ET

Z

S.

M

IT

C

H

EL

L

CD101

BU

IL

D

IN

G

D

EM

O

LI

TI

O

N P

LA

N

W W

E E

LEGEND

EXISTING WATER MAIN

EXISTING PRIMARY UNDERGROUND ELECTRIC

EXISTING SECONDARY UNDERGROUND ELECTRIC

EXISTING PAD MOUNTED TRANSFORMER

ES ES

DEMOLISH BUILDING 1411

DEMOLISH EXISTING

PAVEMENT

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

W W

E E

E E

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

ES

DEMOLISH EXISTING UNDERGROUND

ELECTRIC FROM IGLOO TO TRANSFORMER

NOTES:

1. SEE PERFORMANCE WORK STATEMENT (PWS) FOR

DEMOLITION DETAILS.

2. SEE BUILDING DESCRIPTION(S), PWS 3.0 DETAILED

DESCRIPTION OF SERVICES.

3. UTILITY LOCATIONS ARE APPROXIMATE.

CONTRACTOR WILL FIELD VERIFY LOCATIONS PRIOR

TO DEMOLITION.

4. PROTECT IN PLACE ALL EXISTING UTILITIES UNLESS

OTHERWISE NOTED.

BUILDING 1432 DEMOLITION PLAN

1"=30'

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

SHEET ID

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

SP

EC

N O

D

ES

IG

N

F

IL

E N

O

D R

AF

T

SU

BM

IT

TA

L

H

IL

L

AI

R F

O R

C E

BA

SE

, U

TA

H B1

AN

D

IG

LO

O

D

EM

O

LI

TI

O

N

J

S

TR

EE

T

SA

C

R

AM

EN

TO

, C A

SA

C

R

AM

EN

TO

D

IS

TR

IC

T

A

PR

AN

SI

D

S.

M

IT

C

H

EL

L

S.

M

IT

C

H

EL

L

L.

N

EM

ET

Z

S.

M

IT

C

H

EL

L

CD102

BU

IL

D

IN

G

D

EM

O

LI

TI

O

N P

LA

N

W W

E E

LEGEND

EXISTING WATER MAIN

EXISTING PRIMARY UNDERGROUND ELECTRIC

EXISTING SECONDARY UNDERGROUND ELECTRIC

EXISTING PAD MOUNTED TRANSFORMER

ES ES

File details come from the government source that posted it. Updated .