The following pages are the preliminary architectural floor by floor plans.

This document is for information only and subject to change.

UP

G

A-201

C1

A-202

A1

A-202

C1

62 3 4 5 7 9 10 11 12

B

C

D

E

F

A

1' - 6" 33' - 8 1/2" 27' - 3" 18' - 8" 23' - 7" 33' - 2" 33' - 2" 3' - 6 1/2" 18' - 11 1/2" 27' - 3" 33' - 8 1/2" 27' - 8" 27' - 8" 27' - 8" 1' - 6"

106' - 6"

185181

175176

171 177

157154 164 167

153 156 159 163 166

155 158 162 165152

117118

122 123

126128

129 127

A.9

DEPARTMENT LEGEND

BREAK

CIRCULATION

CONFERENCE

LAB

MECHANICAL /

ELECTRICAL / COMM

OPEN OFFICE

PRINTING (P) /

STORAGE (S)

PRINTING / STORAGE

PRIVATE OFFICE

RESTROOM /

MOTHER'S ROOM

7.1

175A

183A

183B

183C

183D

148B

187A

194A

MECHANICAL

PLATFORM

148A ABOVE

MECHANICAL

PLATFORM

173A ABOVE

185A

144B

144A

SEE

A1/A-102

FOR

UPPER

LEVEL

SEATING

C1

A-301

C1

A-301

A1

A-302

A1

A-302

B1

A-301

B1

A-301

A1

A-301

A1

A-301

B1

A-302

B1

A-302

C1

A-302

C1

A-302

C1

A-303

C1

A-303

339' - 0"

11' - 0"

LOADING AREA

DIESEL GENERATOR

DIESEL GENERATOR

DIESEL GENERATOR

GENERAL FLOOR PLAN NOTES:

1.

2.

REFERENCE DRAWINGS A-161 THRU A-163 FOR

SECURITY LEGEND

REFERENCE DRAWING A-164 THRU A-176 FOR SECURITY

CONTROL DRAWINGS

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H G

R O

U N

D B

A S

E D

S T

R A

T E

G

IC

D E

F E

N S

E P

R O

J E

C T

N O

K

R S

M

S O

U T

H P

A C

IF

IC

D

IV

IS

IO

N S

A C

R A

M E

N T

O D

IS

T

R

IC

T

Sacramento District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S O

F

E N

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

C O

P Y

R

IG

H T

B

U R

N S

A N

D M

C D

O N

N E

L L E

N G

IN

E

E R

IN

G

C O

M P

A N

Y

IN

C

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E x

F

IL

E N

A M

E

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

D D

C O

D E

M A

Y

X X

W -0

-D

-0

-2

-0

PRELIMINARY - NOT FOR CONSTRUCTION

DRAWINGS ARE INTENDED AS A

SUPPLEMENT TO SECTION 01 10 10,

AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN FINAL LAYOUT AND

DESIGN SHALL BE THE SOLE

RESPONSIBILITY OF THE DESIGN-

BUILD TEAM. ANY CHANGES TO THE

SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE

CONTRACTING OFFICER.

5/14/2019 1:48:19 PM

D e s ig n e r

A u th o r

C h e c k e r

97952A-101

A -1

-0

A p p ro v e r

A-101

G R

O U

N D

F L O

O R

P L A

N

SCALE: 1/16" = 1'-0"A1

GROUND FLOOR PLAN

0 8' 16' 32'

GROUND FLOOR ROOM SCHEDULE

NUMBER NAME AREA

111 MECHANICAL ROOM 492 SF

112 WOMEN'S RESTROOM 261 SF

113 MEN'S RESTROOM 242 SF

114 SECURE LOBBY 787 SF

115 COMMAND OPEN OFFICE 1,124 SF

116 PSM OFFICE 171 SF

117 EMD OFFICE 171 SF

118 DEPUTY MILITARY OFFICER OFFICE 171 SF

119 COMMMANDER OFFICE 366 SF

121 DEPUTY COMMANDER OFFICE 320 SF

122 VESTIBULE 54 SF

123 TOILET / SHOWER 65 SF

124 STORAGE 16 SF

125 STORAGE 16 SF

126 CHIEF ENGINEER OFFICE 180 SF

127 DAG OFFICE 80 SF

128 PRINT AREA 106 SF

129 SECURE CONFERENCE ROOM 190 SF

130 ELEVATOR CONTROLLER ROOM 21 SF

131 BREAK ROOM 90 SF

132 CONFERENCE ROOM 342 SF

133 HALL 97 SF

134 MEN'S RESTROOM 59 SF

135 WOMEN'S RESTROOM 59 SF

136 SINGLE USER TOILET 62 SF

137 UNSECURE LOBBY 262 SF

138 STAIR A 295 SF

139 JANITOR 42 SF

141 SINGLE USER TOILET 54 SF

142 MOTHER'S ROOM 56 SF

143 SECURE LOBBY 554 SF

144 COMPUTER LAB 1,355 SF

144A BREAK / PRINT 80 SF

144B VESTIBULE 44 SF

145 MAIN ELECTRICAL ROOM 964 SF

146 MAIN COMMUNICATIONS ROOM 77 SF

147 FIRE PUMP ROOM 117 SF

148 MAIN MECHANICAL ROOM 2,029 SF

148B ELEVATOR EQUIPMENT ROOM 67 SF

149 COMMUNICATIONS ROOM 223 SF

151 ELECTRICAL ROOM 115 SF

152 OPEN OFFICE 363 SF

153 COMMUNICATIONS ROOM 80 SF

154 SERVER ROOM 758 SF

155 OPEN OFFICE 363 SF

156 COMMUNICATIONS ROOM 82 SF

157 SERVER ROOM 755 SF

158 FUTURE OPEN OFFICE 363 SF

159 FUTURE COMMUNICATIONS ROOM 82 SF

161 FUTURE SERVER ROOM 756 SF

162 OPEN OFFICE 363 SF

163 COMMUNICATIONS ROOM 81 SF

164 SERVER ROOM 757 SF

165 OPEN OFFICE 363 SF

166 COMMUNICATIONS ROOM 80 SF

167 SERVER ROOM 757 SF

168 ELECTRICAL ROOM 1,307 SF

169 VESTIBULE 68 SF

170 STORAGE ROOM 545 SF

171 CORRIDOR 296 SF

172 HALL 140 SF

173 RECEIVING BAY 906 SF

174 SECURE VESTIBULE 321 SF

175 SUPPLY PROC. ROOM 601 SF

175A PMEL-SC 171 SF

176 PARTS STORAGE 726 SF

177 STAIR B 275 SF

178 CORRIDOR 1,549 SF

179 BATTERY LAB 316 SF

181 1,205 SF

LAB

70 SF

183 3,506 SF

183A OPERATIONAL KEY DISTRIBUTION 665 SF

183B VESTIBULE 36 SF

183C 490 SF

183D VESTIBULE 63 SF

184 ELECTRICAL ROOM 70 SF

185 SUPPORT LAB 1,086 SF

185A CABLE TESTING & MODIFICATION 251 SF

186 CORRIDOR 1,537 SF

187 1,730 SF

187A STORAGE 481 SF

188 4,044 SF

189 384 SF

191 2,882 SF

192 1,957 SF

193 3,281 SF

194 3,829 SF

194A STORAGE 195 SF

195 CORRIDOR 786 SF

196 STAIR C 254 SF

197 CORRIDOR 100 SFGROUND FLOOR ROOM SCHEDULE

NUMBER NAME AREA

101 VESTIBULE 134 SF

102 UNSECURE MAIN LOBBY 1,371 SF

103 AUDITORIUM LOBBY 521 SF

104 AUDITORIUM 2,919 SF

104 AUDITORIUM 180 SF

105 HALL 407 SF

106 WOMEN'S RESTROOM 222 SF

107 MEN'S RESTROOM 222 SF

108 SECURITY / BADGING 215 SF

109 COMMUNICATIONS ROOM 86 SF

N

GROSS AREA SCHEDULE

LEVEL AREA

GROUND FLOOR 64,196 SF

SECOND FLOOR 37,705 SF

THIRD FLOOR 37,725 SF

TOTAL CANOPY AREA @ 1/2SF 300 SF

TOTAL GROSS AREA 139,926 SF

KEYNOTE LEGEND

KEY VALUE KEYNOTE TEXT

01 TOOL / TEST EQUIPMENT

02 OPEN OFFICE

LAB

LAB

LAB

LAB

LAB

LAB

LAB

LAB

LAB

LAB

DN

UP

DN

UP

G

A-201

C1

A-202

A1

A-202

C1

62 3 4 5 7 9 10 11 12

B

C

D

E

F

A

216 215

202203

287 288

291 289

235 236

254 255

262 263

249242 241 251232

227 229

292 284

274273

264286217

218 245 258

1' - 6" 33' - 8 1/2" 27' - 3" 18' - 8" 23' - 7" 33' - 2" 33' - 2"

3' - 6 1/2"

18' - 11 1/2" 27' - 3" 33' - 8 1/2" 27' - 8" 27' - 8" 27' - 8" 1' - 6"

A.9

DEPARTMENT LEGEND

BREAK

CIRCULATION

COLLABORATION

SPACE

CONFERENCE

LAB

MECHANICAL /

ELECTRICAL / COMM

OPEN OFFICE

PRINTING /

STORAGE

PRIVATE OFFICE

RESTROOM /

MOTHER'S

ROOM

7.1

227A

C1

A-301

C1

A-301

A1

A-302

A1

A-302

B1

A-301

B1

A-301

A1

A-301

A1

A-301

B1

A-302

B1

A-302

C1

A-302

C1

A-302

C1

A-303

C1

A-303

339' - 0"

106' - 6" 232' - 6"

GENERAL FLOOR PLAN NOTES:

1.

2.

REFERENCE DRAWINGS A-161 THRU A-163 FOR

SECURITY LEGEND

REFERENCE DRAWING A-164 THRU A-176 FOR SECURITY

CONTROL DRAWINGS

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H G

R O

U N

D B

A S

E D

S T

R A

T E

G

IC

D E

F E

N S

E P

R O

J E

C T

N O

K

R S

M

S O

U T

H P

A C

IF

IC

D

IV

IS

IO

N S

A C

R A

M E

N T

O D

IS

T

R

IC

T

Sacramento District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

C O

P Y

R

IG

B

U R

N S

A N

D M

C D

O N

N E

L L E

N G

IN

E

E R

IN

G

C O

M P

A N

Y

IN

C

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E x

F

IL

E N

A M

E

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

D D

C O

D E

M A

Y

X X

W -0

-D

-0

-2

-0

PRELIMINARY - NOT FOR CONSTRUCTION

DRAWINGS ARE INTENDED AS A

SUPPLEMENT TO SECTION 01 10 10,

AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN FINAL LAYOUT AND

DESIGN SHALL BE THE SOLE

RESPONSIBILITY OF THE DESIGN-

BUILD TEAM. ANY CHANGES TO THE

SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE

CONTRACTING OFFICER.

5/14/2019 1:48:30 PM

D e s ig n e r

A u th o r

C h e c k e r

97952A-102

A -1

-0

A p p ro v e r

A-102

S E

C O

N D

F L O

O R

P L A

N

SCALE: 1/16" = 1'-0"A1

SECOND FLOOR PLAN

SECOND FLOOR ROOM SCHEDULE

NUMBER NAME AREA

201 LOBBY 476 SF

202 COMMUNICATIONS ROOM 223 SF

203 ELECTRICAL ROOM 112 SF

204 MECHANICAL ROOM 836 SF

205 MOTHER'S ROOM 56 SF

206 JANITOR 42 SF

207 SINGLE USER TOILET 54 SF

208 WOMEN'S RESTROOM 319 SF

209 MEN'S RESTROOM 288 SF

211 HALL 231 SF

212 TRASH 80 SF

213 STAIR A 295 SF

214 BREAK ROOM 275 SF

215 OFFICE 120 SF

216 OFFICE 120 SF

217 SOFTWARE TEAM 4,878 SF

218 COLLABORATION 81 SF

219 PRINTING 81 SF

220 COLLABORATION 111 SF

221 COMMUNICATIONS ROOM 136 SF

222 CONFERENCE ROOM 443 SF

223 HALL 94 SF

224 VESTIBULE 48 SF

225 COMMUNICATIONS ROOM 96 SF

226 CONFERENCE ROOM 230 SF

227 PROGRAM SECURITY OPEN

OFFICE

642 SF

227A COLLABORATION 94 SF

228 OFFICE 132 SF

229 OFFICE 128 SF

231 PRINTING 68 SF

232 VESTIBULE 48 SF

233 CORRIDOR 259 SF

234 COLLABORATION 58 SF

235 COLLABORATION 42 SF

236 COLLABORATION 42 SF

237 COLLABORATION 58 SF

238 VESTIBULE 53 SF

239 PRINTING 75 SF

241 COMMUNICATIONS ROOM 96 SF

242 SECURITY LAB OPEN OFFICE 434 SF

243 COMPUTER LAB 377 SF

244 CONFERENCE ROOM 230 SF

245 COLLABORATION 106 SF

246 VESTIBULE 56 SF

247 STAIR C 254 SF

248 CORRIDOR 190 SF

249 COMMUNICATIONS ROOM 136 SF

251 PRINT ROOM 72 SF

252 CONFERENCE ROOM 614 SF

253 SECURITY / IA OPEN OFFICE 1,588 SF

254 OFFICE 135 SF

255 OFFICE 135 SF

256 CONFERENCE ROOM 358 SF

257 PRINTING 41 SF

258 COLLABORATION 41 SF

259 1,006 SF

261 BREAK ROOM 89 SF

262 COMMUNICATIONS ROOM 87 SF

263 ELECTRICAL ROOM 89 SF

264 CORRIDOR 403 SF

265 COMPUTER LAB 481 SF

266 COMPUTER LAB 481 SF

267 COMPUTER LAB 481 SF

268 1,006 SF

269 COLLABORATION 41 SF

271 PRINT AREA 41 SF

272 CONFERENCE ROOM 358 SF

273 BREAK ROOM 89 SF

274 COMMUNICATIONS ROOM 87 SF

275 COMMUNICATIONS ROOM 89 SF

276 CORRIDOR 379 SF

277 STAIR B 275 SF

278 CORRIDOR 33 SF

279 SECURE PC BUILD 541 SF

280 PRINT ROOM 82 SF

281 STORAGE 168 SF

282 IT DEPARTMENT / PC BUILD 541 SF

283 STORAGE 168 SF

284 COLLABORATION 81 SF

285 OPEN OFFICE 10,129 SF

286 CORRIDOR 189 SF

287 CONFERENCE ROOM 399 SF

288 CONFERENCE ROOM 201 SF

289 CONFERENCE ROOM 300 SF

291 CONFERENCE ROOM 300 SF

292 COLLABORATION 81 SF

0 8' 16' 32' N

GROSS AREA SCHEDULE

LEVEL AREA

GROUND FLOOR 64,196 SF

SECOND FLOOR 37,705 SF

THIRD FLOOR 37,725 SF

TOTAL CANOPY AREA @ 1/2SF 300 SF

TOTAL GROSS AREA 139,926 SF

COLLABORATION

DN

G

A-201

C1

A-202

A1

A-202

C1

62 3 4 5 7 9 10 11 12

B

C

D

E

F

A

33' - 8 1/2" 27' - 3" 18' - 8" 23' - 7" 33' - 2" 33' - 2"

3' - 6 1/2"

18' - 11 1/2" 27' - 3" 33' - 8 1/2" 27' - 8" 27' - 8" 27' - 8"

317 323

316 315 314

318 319 321 322

327 328331

334 335 336

342 343 344

355 347

302303

351 352

354 353

A.9

DEPARTMENT LEGEND

BREAK

CIRCULATION

COLLABORATION

SPACE

CONFERENCE

MECHANICAL /

ELECTRICAL / COMM

OPEN OFFICE

PRINTING / STORAGE

PRIVATE OFFICE

RESTROOM /

MOTHER'S ROOM

7.1

ROOF

C1

A-301

C1

A-301

A1

A-302

A1

A-302

B1

A-301

B1

A-301

A1

A-301

A1

A-301

B1

A-302

B1

A-302

C1

A-302

C1

A-302

C1

A-303

C1

A-303

ROOF

256' - 0"

173' - 3" 82' - 9"

10' - 1" 1' - 4"

GENERAL FLOOR PLAN NOTES:

1.

2.

REFERENCE DRAWINGS A-161 THRU A-163 FOR

SECURITY LEGEND

REFERENCE DRAWING A-164 THRU A-176 FOR SECURITY

CONTROL DRAWINGS

H

IL

L A

IR

F

O R

C E

B A

S E

U

T A

H G

R O

U N

D B

A S

E D

S T

R A

T E

G

IC

D E

F E

N S

E P

R O

J E

C T

N O

K

R S

M

S O

U T

H P

A C

IF

IC

D

IV

IS

IO

N S

A C

R A

M E

N T

O D

IS

T

R

IC

T

Sacramento District

US Army Corps of

Engineers ®

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R N

O

U S

A R

M Y

C O

R P

S

G

IN

E E

R S

SHEET

IDENTIFICATION

1 2 3 4 5

D

C

B

A

C O

P Y

R

IG

B

U R

N S

A N

D M

C D

O N

N E

L L E

N G

IN

E

E R

IN

G

C O

M P

A N

Y

IN

C

FILE:

DATE:

W

A R

D P

A R

K W

A Y

K A

N S

A S

C

IT

Y

M O

B U

R N

S

M c D

O N

N E

L L

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E x

F

IL

E N

A M

E

C H

E C

K E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

C A

D D

C O

D E

M A

Y

X X

W -0

-D

-0

-2

-0

PRELIMINARY - NOT FOR CONSTRUCTION

DRAWINGS ARE INTENDED AS A

SUPPLEMENT TO SECTION 01 10 10,

AND PROVIDED AS A CONCEPTUAL

BASIS OF DESIGN FINAL LAYOUT AND

DESIGN SHALL BE THE SOLE

RESPONSIBILITY OF THE DESIGN-

BUILD TEAM. ANY CHANGES TO THE

SITE LAYOUT OR FLOOR PLAN WILL

REQUIRE APPROVAL OF THE

CONTRACTING OFFICER.

5/14/2019 1:48:42 PM

D e s ig n e r

A u th o r

C h e c k e r

97952A-103

A -1

-0

A p p ro v e r

A-103

T H

IR

D

F L O

O R

P L A

N

THIRD FLOOR ROOM SCHEDULE

NUMBER NAME AREA

301 LOBBY 476 SF

302 COMMUNICATIONS ROOM 223 SF

303 ELECTRICAL ROOM 112 SF

304 MECHANICAL ROOM 813 SF

305 MOTHER'S ROOM 56 SF

306 JANITOR 42 SF

307 SINGLE USER TOILET 54 SF

308 WOMEN'S RESTROOM 319 SF

309 MEN'S RESTROOM 288 SF

311 HALL 231 SF

312 TRASH 80 SF

313 STAIR A 295 SF

314 BREAK ROOM 275 SF

315 OFFICE 120 SF

316 OFFICE 120 SF

317 COLLABORATION 81 SF

318 COLLABORATION 58 SF

319 COLLABORATION 42 SF

321 COLLABORATION 42 SF

322 COLLABORATION 59 SF

323 COLLABORATION 81 SF

324 VESTIBULE 56 SF

325 STAIR C 257 SF

326 COLLABORATION 81 SF

327 OFFICE 135 SF

328 OFFICE 135 SF

329 CONFERENCE ROOM 358 SF

331 PRINT AREA 41 SF

332 1,006 SF

333 COLLABORATION 41 SF

334 BREAK ROOM 89 SF

335 COMMUNICATIONS ROOM 87 SF

336 ELECTRICAL ROOM 89 SF

337 CORRIDOR 358 SF

338 1,012 SF

339 COLLABORATION 41 SF

341 PRINT AREA 35 SF

342 BREAK ROOM 89 SF

343 COMMUNICATIONS ROOM 87 SF

344 PRINT ROOM 89 SF

345 CONFERENCE ROOM 358 SF

346 STAIR B 275 SF

347 COLLABORATION 81 SF

348 OPEN OFFICE 25,233 SF

349 CORRIDOR 189 SF

351 CONFERENCE ROOM 399 SF

352 CONFERENCE ROOM 201 SF

353 CONFERENCE ROOM 300 SF

354 CONFERENCE ROOM 300 SF

355 COLLABORATION 81 SF

356 COLLABORATION 81 SF

SCALE: 1/16" = 1'-0"A1

THIRD FLOOR PLAN

GROSS AREA SCHEDULE

LEVEL AREA

GROUND FLOOR 64,196 SF

SECOND FLOOR 37,705 SF

THIRD FLOOR 37,725 SF

TOTAL CANOPY AREA @ 1/2SF 300 SF

TOTAL GROSS AREA 139,926 SF

0 8' 16' 32' N