A07.02_-_IFB_-_Atch_12_Appendix_04__Lab_Test_Results_B231,_B232,_B246.pdf

PDF 168 KB Posted

Attached to
Repair Roofs B231, 232, 241, and 246 at DDJC Tracy, CA
Solicitation number
W91238-19-B-0008
Issued by

About this file

Atch 12 Lab Test Results

View the file

Other files

File Type Posted
B01.01_-_Abstract_of_Offers_at_Bid_Opening_W91238-19-B-0008_14_May_19.pdf PDF
B01.01_-_Abstract_Continuation_Sheet_1.pdf PDF
A07.02_-_IFB_-_Atch_13_Appendix_05__As-Built_Building_231.pdf PDF
A07.02_-_Amendment_W91238-19-B-0008-0003.pdf PDF
A07.02_-_IFB_-_20190426_REV_-_Atch_10_Appendix_03_-_Specifications_for_R....pdf PDF
A07.02_-_IFB_-_20190426_REV_-_Atch_01_SOW_Repair_Replace_Roofs,_Bldgs.__....pdf PDF
A07.02_-_W91238-19-B-0008_Amendment_0002.pdf PDF
A07.02_-_IFB_-_Atch_11_Site_Visit_Badge_Request.xlsx XLSX spreadsheet
A07.02_-_Amendment_W91239-19-B-0008-0001.pdf PDF
A07.01_-_IFB_-_Atch_10_Appendix_03_-_Specifications_for_Repair_Replace_Roofs,_Bldgs.__231,_232,....pdf PDF
A07.01_-_IFB_-_Atch_09_Appendix_02_-_Environmental_Checklist.pdf PDF
A07.01_-_IFB_-_Atch_08_Appendix_1d_-_Drawings_Roof_Buildings_246.pdf PDF
A07.01_-_IFB_-_Atch_04_Contract_Acknowlegement_21_Dec_18.pdf PDF
A07.01_-_IFB_-_Atch_07_Appendix_1c_-_Drawings_Roof_Buildings_241.pdf PDF
A07.01_-_IFB_-_Atch_02_Supplemental_Contract_Requirements_21_Dec_18.pdf PDF
A07.01_-_IFB_-_Atch_06_Appendix_1b_-_Drawings_Roof_Buildings_232.pdf PDF
A07.01_-_IFB_-_Atch_03_Davis_Bacon_Wage_Determination_7_Dec_18.pdf PDF
A07.01_-_Solicitation_W91238-19-B-0008.pdf PDF
A07.01_-_IFB_-_Atch_05_Appendix_1a_-_Drawings_Roof_Buildings_231.pdf PDF
A07.01_-_IFB_-_Atch_01_SOW_Repair_Replace_Roofs,_Bldgs.__231,_232,_241,_246_-_27_Mar_19.pdf PDF
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date of Evaluation: 05 April 2018 Location: DLA San Joaquin, Building 231 Subject: Suspect Asbestos Containing Material (SACM), Roofing, Laboratory Analytical Results

Background On 05 April 2018, one bulk sample was collected from the roofing materials associated with the DLASJ, Building 231. Robert Miller, a Division of Occupational Safety and Health Certified Asbestos Consultant for the State of California, CAC # 95-1821, collected the bulk sample. The bulk sample was submitted to Micro Analytical Laboratories, Inc., Emeryville, California for analysis. The AHERA-recommended analytical procedure polarized light microscopy (EPA Method/600/R-93/116) was used for the laboratory analysis of the bulk sample.

Bulk Sample 0504-231-01: The roof is composed of roofing shingles, cellulose felt, and fiberglass felt over a wood substrate. The laboratory did not detect asbestos in the bulk sample collected from these roofing materials. No further action is required.

Robert Miller, CIH, CAC Certified Industrial Hygienist Certified Asbestos Consultant

Location: DLA San Joaquin, Building 232 Subject: Suspect Asbestos Containing Material (SACM), Roofing, Laboratory Analytical Results

Background On 05 April 2018, one bulk sample was collected from the roofing materials associated with the DLASJ, Building 232. Robert Miller, a Division of Occupational Safety and Health Certified Asbestos Consultant for the State of California, CAC # 95-1821, collected the bulk sample. The bulk sample was submitted to Micro Analytical Laboratories, Inc., Emeryville, California for analysis. The AHERA-recommended analytical procedure polarized light microscopy (EPA Method/600/R-93/116) was used for the laboratory analysis of the bulk sample.

Bulk Sample 0504-232-01: The roof is composed of roofing shingles, cellulose felt, and fiberglass felt over a wood substrate. The laboratory did not detect asbestos in the bulk sample collected from these roofing materials. No further action is required.

Location: DLA San Joaquin, Building 246 Subject: Suspect Asbestos Containing Material (SACM), Roofing, Laboratory Analytical Results

Background On 05 April 2018, one bulk sample was collected from the roofing materials associated with the DLASJ, Building 246. Robert Miller, a Division of Occupational Safety and Health Certified Asbestos Consultant for the State of California, CAC # 95-1821, collected the bulk sample. The bulk sample was submitted to Micro Analytical Laboratories, Inc., Emeryville, California for analysis. The AHERA-recommended analytical procedure polarized light microscopy (EPA Method/600/R-93/116) was used for the laboratory analysis of the bulk sample.

Bulk Sample 0504-246-01: The roof is composed of foam, gray paint, and tar adhesive (mastic). The laboratory did not detect asbestos in the bulk sample collected from these roofing materials. No further action is required.