Date of Evaluation: 05 April 2018 Location: DLA San Joaquin, Building 231 Subject: Suspect Asbestos Containing Material (SACM), Roofing, Laboratory Analytical Results
Background On 05 April 2018, one bulk sample was collected from the roofing materials associated with the DLASJ, Building 231. Robert Miller, a Division of Occupational Safety and Health Certified Asbestos Consultant for the State of California, CAC # 95-1821, collected the bulk sample. The bulk sample was submitted to Micro Analytical Laboratories, Inc., Emeryville, California for analysis. The AHERA-recommended analytical procedure polarized light microscopy (EPA Method/600/R-93/116) was used for the laboratory analysis of the bulk sample.
Bulk Sample 0504-231-01: The roof is composed of roofing shingles, cellulose felt, and fiberglass felt over a wood substrate. The laboratory did not detect asbestos in the bulk sample collected from these roofing materials. No further action is required.
Robert Miller, CIH, CAC Certified Industrial Hygienist Certified Asbestos Consultant
Location: DLA San Joaquin, Building 232 Subject: Suspect Asbestos Containing Material (SACM), Roofing, Laboratory Analytical Results
Background On 05 April 2018, one bulk sample was collected from the roofing materials associated with the DLASJ, Building 232. Robert Miller, a Division of Occupational Safety and Health Certified Asbestos Consultant for the State of California, CAC # 95-1821, collected the bulk sample. The bulk sample was submitted to Micro Analytical Laboratories, Inc., Emeryville, California for analysis. The AHERA-recommended analytical procedure polarized light microscopy (EPA Method/600/R-93/116) was used for the laboratory analysis of the bulk sample.
Bulk Sample 0504-232-01: The roof is composed of roofing shingles, cellulose felt, and fiberglass felt over a wood substrate. The laboratory did not detect asbestos in the bulk sample collected from these roofing materials. No further action is required.
Location: DLA San Joaquin, Building 246 Subject: Suspect Asbestos Containing Material (SACM), Roofing, Laboratory Analytical Results
Background On 05 April 2018, one bulk sample was collected from the roofing materials associated with the DLASJ, Building 246. Robert Miller, a Division of Occupational Safety and Health Certified Asbestos Consultant for the State of California, CAC # 95-1821, collected the bulk sample. The bulk sample was submitted to Micro Analytical Laboratories, Inc., Emeryville, California for analysis. The AHERA-recommended analytical procedure polarized light microscopy (EPA Method/600/R-93/116) was used for the laboratory analysis of the bulk sample.
Bulk Sample 0504-246-01: The roof is composed of foam, gray paint, and tar adhesive (mastic). The laboratory did not detect asbestos in the bulk sample collected from these roofing materials. No further action is required.