A01.13_Appendix_1_Drawings_Gate_House_106.pdf

PDF 4 MB Posted

Attached to
Building 106, New Gate House, Defense Logistics Agency (DLA), DDJC Tracy, CA
Solicitation number
W91238-17-R-0070
Issued by

About this file

Appendix 1 Drawings

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T16T16

T15T15

T58 Under Construction

T58 Under Construction

Construction Trailer

Construction Trailer

R A

M P

R A

M P

R A

M P

R A

M P

R A

M P

GATE 5 GATE 3

SCALE

TRUCK

PARKING

POV

GATE 9

AREA C

OPEN STORAGE

GATE 2

TANK

WATER STORAGE

HELIPAD

LAGOONS

SEWAGE

GATE 10

OPEN

OPEN STORAGE AREA B

AREA A

STORAGE

UNION PACIFIC RAILROAD

BATES ROAD

CHRISMAN ROAD

FLAME ST

D S

TR

EE

T

7TH STREET

6TH STREET

5TH STREET

C

ST

RE

ET

4TH STREET

3RD STREET

2ND STREET

POV PARKING

1ST STREET

AREA

A

R

OAD

PLANT STREET

D STREET

9TH STREET

B

ST

RE

ET

POV PARKING

PARKING

POV PARKING

PARKING

POV

HOLDING RESERVOIR

STORM DRAINAGE

4TH STREET

2ND STREET

1ST STREET

CHRISMAN ROAD

POV PARKING

A S

TR

EE

T

WEST STREET

5TH STREET

1ST STREET

2ND STREET

4TH STREET

5TH STREET

8TH STREET

7TH STREET

SO

U

TH

ER

N P

AC

IF

IC

R

AI

LR

O

AD

MEDICAL STREET

7TH STREET

POV PARKING

12TH STREET

B

ST

RE

ET

C

ST

RE

ET

11TH STREET

10TH STREET

9TH STREET

POV PARKING

ARE

A A

R

OAD

A

ST

RE

ET

9TH STREET

8TH STREET8TH STREET

7TH STREET

8TH STREET

9TH STREET

T29T29

T30T30

T13T13

T14T14

T17T17

T20T20 T19T19

T21T21

T22T22

T27T27

T56T56

T1T1

T18T18

T28T28

T6T6

T3T3

T255T255

T238T238

T247T247

T237T237

T234T234

T232T232

T231T231

T220T220

T201T201

T100T100

Police Station (Future)

Police Station (Future) T101T101

T250T250

T258T258

T246T246

T205T205

T006T006

T40T40 T241T241

T31T31

T220T220

T221T221

T57T57

E1E1

E2E2

E3E3 480’480’

550’550’

70’70’

615’615’

315’315’

35’35’

480’480’

E4E4

325’325’ 475’475’

450’450’375’375’

N24N24 N37N37

N39N39

N50N50 E53E53

200’200’ 110’110’ 100’100’

100’100’

CO

N

ST

RU

CTION PROJECT

CO

N

ST

RU

CTION PROJECT

2 2

400’400’ 555’555’

400’400’400’400’410’410’

300’300’

52’52’ 260’260’

321’321’

54’54’

130’130’

284’284’

Enlarge Existing VaultEnlarge Existing Vault E5E5

E6E6

E7E7

E8E8

N15N15 N17N17 N21N21 N23N23

266’266’

CO

N

ST

RU

CTION PROJECT

CO

N

ST

RU

CTION PROJECT

2 existing conduits stop2 existing conduits stop at 5’ - need to continue to T29at 5’ - need to continue to T29 approximately 295’approximately 295’

E9E9

E10E10

E11E11

E12E12 E13E13 E14E14 E16E16 E18E18 E19E19 E20E20 E22E22

4 4

2 2

300’300’

282’282’ 352’352’

398’398’

396’396’

102’102’

350’350’

192’192’ 80’80’

342’342’

135’135’

316’316’ 125’125’

28’28’ 160’160’ 251’251’ 814’814’

Enlarge Existing VaultEnlarge Existing Vault

CO

N

ST

RU

CTION PROJECT

CO

N

ST

RU

CTION PROJECT

E25E25

E26E26

E27E27

E28E28

116’116’

350’350’

300’300’

375’375’

280’280’

280’280’

CO

N

ST

RU

CTION PROJECT

CO

N

ST

RU

CTION PROJECT

E29E29

E30E30

E31E31

N32N32

N33N33

N34N34

N35N35

300’300’

240’240’

100’100’

35’35’100’100’

100’100’ 35’35’

467’467’

120’120’

169’169’

300’300’

660’660’

30’30’ need to verify

CO

NSTRUCTION PRO

JECT

CO

NSTRUCTION PRO

JECT

250’250’

N36N36 N38N38

N48N48

N41N41

350’350’ 350’350’

350’350’

350’350’

40’40’ 500’500’ aerial backaerial back to manholeto manhole

200’200’ N49N49

240’240’

CONSTRUCTION PROJECT

CONSTRUCTION PROJECT

80’80’

N45N45

N46N46

N47N47

40’40’

75’75’

40’40’

55’55’

250’250’

260’260’

40’40’

60’60’

70’70’

350’350’ aerial backaerial back to manholeto manhole

1400’1400’ aerial backaerial back to manholeto manhole

2700’2700’ aerial backaerial back to manholeto manhole

40’40’

N52N52

300’300’

245’245’

CONSTRUC

TI

O N

PR

OJECT

CONSTRUC

TI

O N

PR

OJECT

N42N42

N43N43

E44E44

N51N51 N54N54

340’340’340’340’

260’260’

100’100’

285’285’

190’190’

CONSTRUCTION PROJECT

CONSTRUCTION PROJECT

E40E40 145’145’

145’145’

30’30’

22 22 22 2+4+4+4

6666666666

+4+4+4

4+2+2+2

22 22

22 22

444444

22 22

Building 100 (west) - 192 s/m + 500 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T100-T30 4891’ - 144 s/m + 400 pair copper T100-T101 625’ - 24 s/m + 50 pair copper T100-Future Police 535' - 24 s/m + 50 pair copper

Building 100 (west) - 192 s/m + 500 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T100-T30 4891’ - 144 s/m + 400 pair copper T100-T101 625’ - 24 s/m + 50 pair copper T100-Future Police 535' - 24 s/m + 50 pair copper

Building T30 - 552 s/m +1550 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T30-T100 4891’ - 144 s/m + 400 pair copper T30-T56 4696’ - 144 s/m + 400 pair copper T30-T13 1026' - 24 s/m + 100 pair copper T30-T14 1354’ - 24 s/m + 100 pair copper T30-T17 1409‘ - 24 s/m + 100 pair copper T30-T20 1916’ - 24 s/m + 100 pair copper T30-T40 1466‘ - 24 s/m + 50 pair copper T30-T29 1035' - 24 s/m + 100 pair copper T30-T3 787’ - 24 s/m + 100 pair copper T30-T6 468‘ - 24 s/m + 100 pair copper T30-T31 2108’ - 24 s/m T30-T220 2688’ - 24 s/m T30-T221 2968’ - 24 s/m

Building T30 - 552 s/m +1550 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T30-T100 4891’ - 144 s/m + 400 pair copper T30-T56 4696’ - 144 s/m + 400 pair copper T30-T13 1026' - 24 s/m + 100 pair copper T30-T14 1354’ - 24 s/m + 100 pair copper T30-T17 1409‘ - 24 s/m + 100 pair copper T30-T20 1916’ - 24 s/m + 100 pair copper T30-T40 1466‘ - 24 s/m + 50 pair copper T30-T29 1035' - 24 s/m + 100 pair copper T30-T3 787’ - 24 s/m + 100 pair copper T30-T6 468‘ - 24 s/m + 100 pair copper T30-T31 2108’ - 24 s/m T30-T220 2688’ - 24 s/m T30-T221 2968’ - 24 s/m

Building T56 - 576 s/m + 1800 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T56-T100 4532’ - 144 s/m + 400 pair copper T56-T30 4696’ - 144 s/m + 400 pair copper T56-T57 2361' - 24 s/m + 100 pair copper T56-T16 405’ - 24 s/m + 100 pair copper T56-T19 1152‘ - 24 s/m + 100 pair copper T56-T21 1452’ - 24 s/m + 100 pair copper T56-T22 1692‘ - 24 s/m + 100 pair copper T56-T28 1387' - 24 s/m + 100 pair copper T56-T18 1087’ - 24 s/m + 100 pair copper T56-T1 2176‘ - 24 s/m + 100 pair copper T56-T15 782’ - 24 s/m + 100 pair copper T56-T27 776‘ - 24 s/m + 50 pair copper T56-Future Building 6 466‘ - 24 s/m + 50 pair copper (left in E28) T56-Future Building 4 1842‘ - 24 s/m + 50 pair copper (left in N35)

Building T56 - 576 s/m + 1800 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T56-T100 4532’ - 144 s/m + 400 pair copper T56-T30 4696’ - 144 s/m + 400 pair copper T56-T57 2361' - 24 s/m + 100 pair copper T56-T16 405’ - 24 s/m + 100 pair copper T56-T19 1152‘ - 24 s/m + 100 pair copper T56-T21 1452’ - 24 s/m + 100 pair copper T56-T22 1692‘ - 24 s/m + 100 pair copper T56-T28 1387' - 24 s/m + 100 pair copper T56-T18 1087’ - 24 s/m + 100 pair copper T56-T1 2176‘ - 24 s/m + 100 pair copper T56-T15 782’ - 24 s/m + 100 pair copper T56-T27 776‘ - 24 s/m + 50 pair copper T56-Future Building 6 466‘ - 24 s/m + 50 pair copper (left in E28) T56-Future Building 4 1842‘ - 24 s/m + 50 pair copper (left in N35)

Building 100 (east) - 552 s/m +1300 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T100-T56 4532’ - 144 s/m + 400 pair copper T100-T201 1070’ - 24 s/m + 50 pair copper T100-T220 1555‘ - 24 s/m + 50 pair copper T100-T231 (Future Buildng 7) 1890’ - 24 s/m + 50 pair copper T100-T232 1855‘ - 24 s/m + 50 pair copper T100-T234 1870' - 24 s/m + 50 pair copper T100-T247 2100’ - 24 s/m + 50 pair copper T100-T241 2370’ - 24 s/m + 50 pair copper T100-T238 2380‘ - 24 s/m + 50 pair copper T100-T237 2570’ - 24 s/m + 50 pair copper T100-T246 2660‘ (350’ aerial) - 24 s/m + 50 pair copper T100-T205 3710’ (1400’ aerial) - 24 s/m + 50 pair copper T100-T258 5010‘ (2700’ aerial) - 24 s/m + 50 pair copper T100-T250 2800‘ (500’ aerial) - 24 s/m + 50 pair copper T100-T006 2580’ - 24 s/m + 50 pair copper T100-T255 2420‘ - 24 s/m + 50 pair copper T100-Future Building 5 2310’ - 24 s/m + 50 pair copper (left in N52) T58 (under construction) 1615’ - 24 s/m + 100 pair copper

Building 100 (east) - 552 s/m +1300 pair copper s/m fiber is home run copper is run in high quantity trunks, peeling off to each building

T100-T56 4532’ - 144 s/m + 400 pair copper T100-T201 1070’ - 24 s/m + 50 pair copper T100-T220 1555‘ - 24 s/m + 50 pair copper T100-T231 (Future Buildng 7) 1890’ - 24 s/m + 50 pair copper T100-T232 1855‘ - 24 s/m + 50 pair copper T100-T234 1870' - 24 s/m + 50 pair copper T100-T247 2100’ - 24 s/m + 50 pair copper T100-T241 2370’ - 24 s/m + 50 pair copper T100-T238 2380‘ - 24 s/m + 50 pair copper T100-T237 2570’ - 24 s/m + 50 pair copper T100-T246 2660‘ (350’ aerial) - 24 s/m + 50 pair copper T100-T205 3710’ (1400’ aerial) - 24 s/m + 50 pair copper T100-T258 5010‘ (2700’ aerial) - 24 s/m + 50 pair copper T100-T250 2800‘ (500’ aerial) - 24 s/m + 50 pair copper T100-T006 2580’ - 24 s/m + 50 pair copper T100-T255 2420‘ - 24 s/m + 50 pair copper T100-Future Building 5 2310’ - 24 s/m + 50 pair copper (left in N52) T58 (under construction) 1615’ - 24 s/m + 100 pair copper

Fiber and Copper Project

Fiber and Copper Project

Fiber and Copper Project

Fiber and Copper Project

Defense Distribution Depot - San Joaquin, CA - Tracy FacilityT30T30

T56T56 s

/m fi be r pa irs c op pe r s

/m fi be r pa irs c op pe r

4891’ - 144 s/m fiber 400 pairs copper

4891’ - 144 s/m fiber 400 pairs copper

Fiber & Copper Backbone

4696’ - 144 s/m fiber 400 pairs copper

4696’ - 144 s/m fiber 400 pairs copper

Legend

New Manhole ID # Approximate distances in feet90’90’

Number of existing conduits between manholes/vaults or buildings2

Existing number of conduits between manholes/ vaults and number of additional (+) conduits needed

Existing Vault/Manhole ID #

Number of new conduits between manholes/vaults or buildings

Existing Manhole

Existing VaultN o

Co lo r N o Co lo r

New 4.5’ x 8.5’ x 6’ Manhole

Fi lle d w ith C ol or

Fi lle d w ith C ol or

+4+4+4 all distances approximate

T100T100

1 Qxx-G-101 Q09-G-101 (1)
2 Qxx-C-101 Q09-C-101 (1)
3 Qxx-A-101 Q09-A-101 (1)
4 Qxx-S-101 Q09-S-101 (1)
5 Qxx-M-101 Q09-M-101 (1)
6 Qxx-P-101 Q09-P-101 (1)
7 Qxx-E-101 Q09-E-101 (1)
8 Qxx-E-102 Q09-E-102 (1)

File details come from the government source that posted it. Updated .