FXDP_SS501_AMD0001.pdf
PDF 229 KB Posted
- Attached to
- FY19 De Pere Dam Walkway Replacement Federal contract opportunity
- Solicitation number
- W911XK19B0009
About this file
Amended Plans Document SS501
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FXDP_SS502_AMD0001.pdf | ||
| W911XK19B0009_0001.pdf | ||
| FXDP_SS301_AMD0001.pdf | ||
| DePere_Hydrogragh_2015.pdf | ||
| Depere_Walkway_As-Builts.pdf | ||
| Plans_Depere_Dam_Walkway_Cert_Final_RTA_24_Apr2019.pdf | ||
| W911XK19B0009_FY19_DePere_Walkway_Replacement.pdf | ||
| Specs_Cert_FINAL_RTA_23apr2019_Depere_Spillway_Walkway_&_Pier_Repairs.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"2 11 4" "2
11 "16
"2
"2
"2
1 3
7"
"16
L 3" X 3" X 3/8"
REQUIRED GALV
BRACING
REQUIRED CROSS
"2 11 4" "2
11 "4
7"
"4
"2
"16
L 3" X 3" X 3/8"
REQUIRED GALV
8 3/4" X 7" X 3/8" PLATE
REQUIRED DS GLAV
8 5/16" X 7" X 3/8" PLATE
REQUIRED DS GLAV
BRACING
REQUIRED CROSS
"2
3"
"2
"2
"4
"2
"2
"2
L 3" X 3" X 3/8"
REQUIRED GALV
9 1/4" X 7" X 3/8" PLATE
REQUIRED GLAV
"16
R 1 1/2"
6"
GALV BOLTS
HOLES FOR 3/8" DIA
REQUIRED 7/16" DIA
REQUIRED GIRDER
REQUIRED GIRDER
7"X4"X3/8"X9"
REQ'D GALV L
GALV PIPE HANDRAIL
REQUIRED 2" DIA STD
RECOMMENDATION
PER MANUFACTURER'S
EQUAL AT EACH HANDRAIL POST BOLTS
REQ'D GALV PIPE STRAP B-LINE 3180 OR
GALV STIFFENER PLATE
REQUIRED 3 15/16" X 1'-7 3/4" X 3/8"
PLATE 1/4" X 6"
REQUIRED GALV TOE
GALV GRATING 19-W-4
REQUIRED 1" X 1/8"
BAR: 3/16" X 2" X 2'-1"
REQUIRED GALV BENT
PLATE 1/4" X 6"
REQUIRED GALV TOE
GRATING 19-W-4
REQUIRED GALV 1" X 1/8"
GIRDER (TYP, FCM)
REQUIRED W21X55
GIRDER (TYP, FCM)
REQUIRED W21X55
GIRDER (TYP, FCM)
REQUIRED W21X55
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
S
A AF
E
Y
Y
T
P S
C O
R P
S
O F
E N
G I
N E
E R
S
D E
T R
O I
T
D I
S T
R I
C T
I n c r e a s e r o f i t
S u b m i t
V
C P
S
V a l u e n g i n e e r i n g
DS: LRE_Screen.dscript.dscriptPD: LRE_pdf.pltcfg9:26:11 AM 6/12/2019
...\Active Projects\OM-Fox River, WI (476278) - Depere Dam Walkway & Pier Repair\3 - CADD\CAD_BIM\_Sheets\
R O J E
C T N
U M
B E
R
F
IL
E N
A M
E
A N
S I
SS501
T R
O
IT
M I
M
IC
H
IG
A N A
V E
D E
T R
O
IT
D
IS
T R
IC
T
W
X K
B
F X
D P S
S .d g n
CERTIFIED FINAL - READY TO ADVERTISE
W A
L K
W A
Y P
IE
R R
E P
A
IR
F O
X R
IV
E R D
E P
E R
E D
A M
D E
P E
R E
W I
B R
O W
N C
O U
N T
Y
A P
R
IL
B
M E
L B
Y
A
W A
D Y
S Z
P
R O
S S
F X
D P
R E
Q U
IR
E D W
A L
K W
A Y S
P A
N
C O
N N
E C
T
IO
N D
E T
A
IL
S
A1
SCALE: 6" = 1' 3"0 6"1-1/2"SS101
F4
A5
SCALE: 6" = 1' 3"0 6"1-1/2"SS101
G6
1/4
FCW
1/4
FCW
E1
CROSS BRACING CONNECTION
SCALE: 6" = 1' 3"0 6"1-1/2"SS301
B6
3/16
E5
SCALE: 3" = 1' 6"0 3" 1'SS301
A1
E8
SCALE: 3" = 1' 6"0 3" 1'SS301
A1HANDRAIL CONNECTION
WRAP ALL FILLET WELDS2.
ALL HOLES 13/16" DIA FOR 3/4" DIA F3125 BOLTS W/ NUT AND WASHER1.
GENERAL SHEET NOTES
D.S. LACING CONNECTION U.S. LACING CONNECTION
FLASH HOOK DETAIL (REMOVED FROM CONTRACT)
J
U N
E
F L
A S
H H
O O
K R
E M
O V
E D A
M D
File details come from the government source that posted it.