FXDP_SS301_AMD0001.pdf
PDF 305 KB Posted
- Attached to
- FY19 De Pere Dam Walkway Replacement Federal contract opportunity
- Solicitation number
- W911XK19B0009
About this file
Amended Plans Document SS301
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FXDP_SS502_AMD0001.pdf | ||
| FXDP_SS501_AMD0001.pdf | ||
| W911XK19B0009_0001.pdf | ||
| DePere_Hydrogragh_2015.pdf | ||
| Depere_Walkway_As-Builts.pdf | ||
| W911XK19B0009_FY19_DePere_Walkway_Replacement.pdf | ||
| Specs_Cert_FINAL_RTA_23apr2019_Depere_Spillway_Walkway_&_Pier_Repairs.pdf | ||
| Plans_Depere_Dam_Walkway_Cert_Final_RTA_24_Apr2019.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"4 32'-3
"8 71'-1"8
71'-1
"16
"8 73'-2
"8 71'-1"8
71'-1
"4 32'-3
REQ'D HAND RAIL POSTS
"8 71'-1"8
71'-1
"4 32'-3
REQ'D STIFFENER PLATE
REQ'D BEARING PLATE
END OF GIRDER END OF GIRDER
C A
M B
E R
REQ'D HAND RAIL
"8 73'-2 "8
73'-2
REQ'D HAND RAIL (TYP)
REQ'D HAND RAIL END
REQ'D CONC PIER
ON ALL CORNERS OF
REQ'D 3/4" CHAMFER
"8 71'-11
APPROX 2'-0"
WALKWAY
GATE RE-INSTALLED ON REQ'D
EXISTING SECURITY FENCE AND
WALKWAY SPAN
REQ'D GALV STEEL 50'
EXISTING CONC ABUTMENT
WALKWAY SPAN
REQ'D GALV STEEL 50'
EXISTING SLUICEWAY PIER #6
PLATE, 1/4" X 6"
REQ'D GALV STEEL TOE
PLATE, 1/4" X 6"
REQ'D GALV STEEL TOE
REQ'D GALV L 3" X 3" X 3/8" LACING
REQ'D GALV L 7" X 4" X 3/8" X 9"
GALV CROSS BRACING
REQ'D L 3" X 3" X 3/8"
REQ'D GALV GUSSET PLATE
PLATE W/ 3/4" F3125 BOLT (TYP)
REQ'D GALV 3" X 3" X 3/8" SPACER
REQ'D GALV STIFFENER PLATE
REQ'D PTFE SLIDE BEARING
REQ'D GROUT
GALV CROSS BRACING
REQ'D L 3" X 3" X 3/8"
REQ'D GALV SPACER PLATE
REQ'D GALV GUSSET PLATE
GRATING, 19-W-4
REQ'D 1" X 1/8" GALV
GRATING, 19-W-4
REQ'D 1" X 1/8" GALV
GRATING, 19-W-4
REQ'D 1" X 1/8" GALV
EQUAL EQUAL
4'-0"
3'-6"
WALKWAY SPAN
REQ'D GALV STEEL 50'
2'-1"
REQ'D C7X14.75 (2) PLACES
ANCHORING EACH C7
EMBEDMENT. (2) REQ'D FOR
CONCRETE ANCHOR, 3" MIN
REQ'D 1/2" DIA MECHANICAL
GIRDERS
ANCHOR WALKWAY
EXISTING CONCRETE TO
SAWCUT NOTCH INTO
GRATING TREAD W/ RISER BAR
REQ'D 1" X 1/8" GALV STEEL
REQ'D U.S. GALV GUSSET PLATE
GUSSET PLATE
REQ'D D.S. GALV
(TYP, FCM)
REQ'D W21X55 GIRDER
(TYP, FCM)
REQ'D W21X55 GIRDER
(TYP, FCM)
REQ'D W21X55 GIRDER
GIRDERS
ANCHOR WALKWAY
EXISTING CONCRETE TO
SAWCUT NOTCH INTO
CONTRACT)
(REMOVED FROM
U.S. SIDE ONLY
REQ'D FLASH BOARD HOOK
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
S
A AF
E
Y
Y
T
P S
C O
R P
S
O F
E N
G I
N E
E R
S
D E
T R
O I
T
D I
S T
R I
C T
I n c r e a s e r o f i t
S u b m i t
V
C P
S
V a l u e n g i n e e r i n g
DS: LRE_Screen.dscript.dscriptPD: LRE_pdf.pltcfg9:26:53 AM 6/12/2019
...\Active Projects\OM-Fox River, WI (476278) - Depere Dam Walkway & Pier Repair\3 - CADD\CAD_BIM\_Sheets\
R O J E
C T N
U M
B E
R
F
IL
E N
A M
E
A N
S I
SS301
T R
O
IT
M I
M
IC
H
IG
A N A
V E
D E
T R
O
IT
D
IS
T R
IC
T
W
X K
B
S E
C T
IO
N S
F X
D P S
S .d g n
W A
L K
W A
Y P
IE
R R
E P
A
IR
F O
X R
IV
E R D
E P
E R
E D
A M
D E
P E
R E
W I
B R
O W
N C
O U
N T
Y
A P
R
IL
B
M E
L B
Y
A
W A
D Y
S Z
P
R O
S S
F X
D P
R E
Q U
IR
E D W
A L
K W
A Y S
P A
N
G1
SCALE: NTS
CAMBER ALL SPANS - TYPICAL
M
ID
S P
A N
C L
C L R
A
IL
IN
G
C L R
A
IL
IN
G
C L W
A L
K W
A Y
C L W
A L
K W
A Y
C L W
A L
K W
A Y
CERTIFIED FINAL - READY TO ADVERTISE
A1
SCALE: 1 1/2" = 1' 1' 2'0 6"SS101
A7
SCALE: 1 1/2" = 1' 1' 2'0 6"SS101
A4
SCALE: 1 1/2" = 1' 1' 2'0 6"SS101
E6
RIGHT ABUTMENT
SCALE: 1/2" = 1' 0 2' 4'1'S-101
E1
CREST EL 587.4'
CONCRETE SPILLWAY
E1
SLUICEWAY PIER #6
SCALE: 1/2" = 1' 0 2' 4'1'S-101
E7
TYPICAL CROSS BRACE SECTIONTYPICAL LACING SECTION CROSS BRACING SECTION @ PIER
EL. 593.79'
TOP OF GRATING
EL. 592.54'
TOP OF ABUTMENT
E3
SCALE: 1/2" = 1'S-101
E7
0 2' 4'1'
RIGHT ABUTMENT NOTCH
RISER BARS SHALL BE MIN 1/4" THICK AND SHALL BE OF A HEIGHT SUCH THAT NO GAPS EXISTS BETWEEN TREADS2.
STEP RISE SHOWN IS APPROXIMATE AND SHALL BE FIELD VERIFIED AND COORDINATED WITH ON SITE GOVERNMENT REPRESENTATIVE.1.
NOTE:
EL. 593.79'
TOP OF GRATING
U.S. SIDE D.S. SIDE
U.S. SIDE D.S. SIDE U.S. SIDE D.S. SIDE
J
U N
E
F L
A S
H H
O O
K R
E M
O V
E D A
M D
NOTCH
SS502
F6
SS501
E1
SS501
E8
SS503
E6
SS503
E6
SS501
E5
SS301
E3
SS301
E3
File details come from the government source that posted it.