MASTER BAA No. W911W6-16-R-0004 CALL No. W911W6-16-R-0005 Next Generation Rotorcraft Transmission (NGRT)

NO.
Question Reference
QUESTION
RESPONSE
01
Call W911W6-16-R-0005, Section 2.0 Technical Description, para., a)
Does 3,500HP – 7,000HP rating range stated in the BAA refer to an OEI power, or an AEO power?
AEO Power
02
Call W911W6-16-R-0005, Section 2.0 Technical Description, para., a)
Is the statement “7 speed shifts per hour is desired” mean that 7 speed changes per hour is desired or 7 shift cycles per hour is desired (shift down to 50% and shift back up to 100%)?
7 speed changes per hour (100% to 50% counts as 1 speed change, and 50% to 100% counts as 1 speed change)
03
Call W911W6-16-R-0005, Section 1.0 Introduction
How much detail is required in the proposal about what the optimal speed ratio for my proposed platform should be if it isn’t 50%?

As part of the proposal, offerors should state what they currently believe is the optimal speed reduction ratio and why they believe that. A more detailed analysis on this optimal reduction ratio should be performed during the proposed effort.