WTD052870P- PLANS AND DRAWINGS- 23 JULY 2021 - W911SG21B0004.pdf

PDF 912 KB Posted

Attached to
Bldg. 1550 Emergency Lights & Repairs
Solicitation number
W911SG21B0004
Issued by

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ANSI D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

CESAR LIMON

C.LIMON

RAFAEL H. ACOSTA

BUILDING 1550 ELECTRICAL REPAIRS AND EMERGENCY LIGHTING

WS-1550-2021-G-G1-01

COVER SHEET

BUILDING 1550

1 05

W H

I T E

S ANDS MIS S I LE

RA

N

G E

B I RTHPLACE

OF

AMERI CA' S MI SSI LE & SPACE

AC

TI

V

IT

Y

HOWARD GUION

CONCURRENCES

Note: Signatures affixed on this sheet indicate official recommendation and approval of all the drawings in this set as indexed on this sheet

Safety

Security

Department

Environmental

Force Protection

Management

Maintenance

Customer 1

Customer 2

DPW

Information

Anti-Terrorism

Fire

Physical

Garrison

Operations &

D

E

S

I

G

N

B

I

D

S

E

T

07/23/21

AutoCAD SHX Text

WHITE SANDS MISSILE RANGE, NEW MEXICO

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS

AutoCAD SHX Text

ENGINEERING DIVISION

S-246

AUGUSTA STREET

ABERDEEN AVENUE

NIKE AVENUE

WELL #10A

NIKE AVENUE

OW

EN

R

OA

D

TO HIGHWAY 70/

LAS CRUCES

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ANSI D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

CESAR LIMON

C.LIMON

RAFAEL H. ACOSTA

WS-1550-2021-G-G1-02

INDEX SHEET/LOCATION MAP

BUILDING 1550

2 05

PROJECT LOCATION BUILDING 1550

LAS CRUCES GATE

HOWARD GUION

D

E

S

I

G

N

B

I

D

S

E

T

SHEET INDEX

DRAWING NUMBER TITLE

WS-1550-2021-G-G1-01 BUILDING 1550 COVER SHEET

WS-1550-2021-G-G1-02 BUILDING 1550 INDEX SHEET/LOCATION MAP

WS-1550-2021-FP-03 BUILDING 1550 DIMENSIONS

WS-1550-2021-E-04

BUILDING 1550 ELECTRICAL LAYOUT FOR EMERGENCY

"EXIT" SIGN/LIGHTS COMBO, WALLPACK, 600 V

RECEPTACLE, 480 V-3 PHASE PANEL, AND 75 KVA

TRANSFORMER DRY TYPE

WS-1550-2021-G-05

BUILDING 1550 KEY NOTES FOR ELECTRICAL LAYOUT

FOR EMERGENCY "EXIT" SIGN/LIGHTS COMBO,

WALLPACK, 600 V RECEPTACLE, 480 V-3 PHASE PANEL,

AND 75 KVA TRANSFORMER DRY TYPE

07/23/21

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1460N

AutoCAD SHX Text S-1547

AutoCAD SHX Text S-1546

AutoCAD SHX Text

AutoCAD SHX Text S-1790

AutoCAD SHX Text S-1858

AutoCAD SHX Text

AutoCAD SHX Text 1438N

AutoCAD SHX Text S-1475N

AutoCAD SHX Text S-1472

AutoCAD SHX Text 456N

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S-1473N

AutoCAD SHX Text

AutoCAD SHX Text B.O.Q.

AutoCAD SHX Text

AutoCAD SHX Text S-1552

AutoCAD SHX Text

AutoCAD SHX Text

FIRE STATION

AutoCAD SHX Text T-145

AutoCAD SHX Text

AutoCAD SHX Text S-1558

AutoCAD SHX Text S-1550

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TELEPHONE

AutoCAD SHX Text

EXCHANGE

AutoCAD SHX Text

AutoCAD SHX Text S-421

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S-1538

AutoCAD SHX Text S-1524

AutoCAD SHX Text

AutoCAD SHX Text V-2

AutoCAD SHX Text S-122

AutoCAD SHX Text

AutoCAD SHX Text 1867-N

AutoCAD SHX Text 1870-N

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S-1781

AutoCAD SHX Text

TANKS

AutoCAD SHX Text S-1799

AutoCAD SHX Text

AutoCAD SHX Text 1866-N

AutoCAD SHX Text 1864-N

AutoCAD SHX Text S-1871

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S-1780

AutoCAD SHX Text S-1774

AutoCAD SHX Text

TANKS

AutoCAD SHX Text S-1862

AutoCAD SHX Text S-1860

AutoCAD SHX Text S-1814

AutoCAD SHX Text S-1856

AutoCAD SHX Text S-1810

AutoCAD SHX Text S-1811

AutoCAD SHX Text S-1813

AutoCAD SHX Text S-1854

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

WTC

AutoCAD SHX Text

AutoCAD SHX Text

POST DENTAL

AutoCAD SHX Text

AutoCAD SHX Text

POST THEATER

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

POST OFFICE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T-149

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S-305

AutoCAD SHX Text S-302

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text T-383

AutoCAD SHX Text S-375A

AutoCAD SHX Text S-375B

AutoCAD SHX Text S-368

AutoCAD SHX Text S-234

AutoCAD SHX Text

AutoCAD SHX Text S-364

AutoCAD SHX Text

AutoCAD SHX Text S-370

AutoCAD SHX Text T-357

AutoCAD SHX Text S-371

AutoCAD SHX Text S-365

AutoCAD SHX Text S-360

AutoCAD SHX Text S-362

AutoCAD SHX Text S-375D

AutoCAD SHX Text S-375C

AutoCAD SHX Text

AutoCAD SHX Text S-374

AutoCAD SHX Text S-391

AutoCAD SHX Text

WELL #16

AutoCAD SHX Text S-322

AutoCAD SHX Text

PARSONS STREET

AutoCAD SHX Text

CROZIER STREET

AutoCAD SHX Text

HEADQUARTERS AVENUE

AutoCAD SHX Text

RAMSEY STREET

AutoCAD SHX Text

CRAIG STREET

AutoCAD SHX Text

HALSEY STREET

AutoCAD SHX Text

BLANDY STREET

AutoCAD SHX Text

NOBLE STREET

AutoCAD SHX Text

HOF STREET

AutoCAD SHX Text

RADFORD STREET

AutoCAD SHX Text

ABERDEEN AVENUE

AutoCAD SHX Text

DYER STREET

AutoCAD SHX Text

BENET STREET

AutoCAD SHX Text

CROZIER STREET

AutoCAD SHX Text

DYER STREET

AutoCAD SHX Text

FLAGLER STREET

AutoCAD SHX Text

BENET STREET

AutoCAD SHX Text

WESSON STREET

AutoCAD SHX Text S-1795

AutoCAD SHX Text

RAMSEY STREET

AutoCAD SHX Text

WESSON STREET

AutoCAD SHX Text

JOLIET STREET

AutoCAD SHX Text

HOF STREET

AutoCAD SHX Text

MILAN STREET

AutoCAD SHX Text

HOF STREET

AutoCAD SHX Text

FRANKFORD STREET

AutoCAD SHX Text

DETROIT STREET

AutoCAD SHX Text

SPRINGFIELD STREET

AutoCAD SHX Text

BENET STREET

AutoCAD SHX Text

ROCK ISLAND AVENUE

AutoCAD SHX Text

WSMR RD. 115

AutoCAD SHX Text

PICATINNY AVENUE

AutoCAD SHX Text

CROZIER STREET

AutoCAD SHX Text

HEADQUARTERS AVENUE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DYER STREET

AutoCAD SHX Text

GATE

AutoCAD SHX Text

CHAPEL

AutoCAD SHX Text S-1812

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ROCK ISLAND AVENUE

AutoCAD SHX Text

AutoCAD SHX Text 1538A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MOUNTAINVIEW

AutoCAD SHX Text

CAFE

AutoCAD SHX Text

POST

AutoCAD SHX Text

HEADQUARTERS

AutoCAD SHX Text

MILITARY PERSONNEL

AutoCAD SHX Text

& ID CARDS

AutoCAD SHX Text

ENGINEERING

AutoCAD SHX Text

ATM

AutoCAD SHX Text

COMMISSARY

AutoCAD SHX Text

BOWLING ALLEY

AutoCAD SHX Text

GYM

AutoCAD SHX Text

GODDARD FIELD

AutoCAD SHX Text

BASEBALL

AutoCAD SHX Text

TENNIS

AutoCAD SHX Text

COURTS

AutoCAD SHX Text

MISSILE PARK

AutoCAD SHX Text

MUSEUM

AutoCAD SHX Text

RANGE CONTROL

AutoCAD SHX Text

J.W. COX

AutoCAD SHX Text

CENTER

AutoCAD SHX Text

WELL #22

AutoCAD SHX Text S-313

AutoCAD SHX Text

HELIPAD

AutoCAD SHX Text

JFK

AutoCAD SHX Text

RECEPTION

AutoCAD SHX Text

CENTER

AutoCAD SHX Text

AutoCAD SHX Text

SITE

AutoCAD SHX Text

QUEEN

AutoCAD SHX Text

AutoCAD SHX Text S-1554

AutoCAD SHX Text

AutoCAD SHX Text

NR

AutoCAD SHX Text

AutoCAD SHX Text

CLINIC

AutoCAD SHX Text

RECREATION

AutoCAD SHX Text

EQUIPMENT

AutoCAD SHX Text

ISSUE

AutoCAD SHX Text

AutoCAD SHX Text

EXCHANGE

AutoCAD SHX Text T-385

AutoCAD SHX Text

FIELDS

AutoCAD SHX Text

SIERRA

AutoCAD SHX Text

CHAPEL

AutoCAD SHX Text

WSFCU

AutoCAD SHX Text

PROFESSIONAL

AutoCAD SHX Text

DEVELOPMENT

AutoCAD SHX Text

CENTER AND LIBRARY

AutoCAD SHX Text

ARTS

AutoCAD SHX Text

AND

AutoCAD SHX Text

CRAFTS

AutoCAD SHX Text

TEMPORARY

AutoCAD SHX Text

LODGING

AutoCAD SHX Text

POOL AND

AutoCAD SHX Text

COMM CTR

AutoCAD SHX Text

(PX)

AutoCAD SHX Text

ACS

AutoCAD SHX Text

POLICE

AutoCAD SHX Text

ITALIAN

AutoCAD SHX Text

CAFE

AutoCAD SHX Text

THRIFT

AutoCAD SHX Text

SHOP

AutoCAD SHX Text

CABLE COMPANY

AutoCAD SHX Text

LAS CRUCES GATE

AutoCAD SHX Text N

N

Approx. 182'

Approx. 114'-3"

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ANSI D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

CESAR LIMON

C.LIMON

RAFAEL H. ACOSTA

WS-1550-2021-E-03

BUILDING 1550

3 05

FLOOR PLAN

DIMENSIONS

HOWARD GUION

1' =16'

D

E

S

I

G

N

B

I

D

S

E

T

07/23/21

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PANEL

2 2 2

3 3

ELECTRICAL LEGEND

DRY TYPE 3 PHASE TRANSFORMER

DISTRIBUTION PANEL

SAFETY FUSE DISCONNECT SWITCH

DISCONNECT SAFETY SWITCH AND

WELDING RECEPTACLE, MECHANICAL

INTERLOCK DEVICE, PIN AND SLEEVE

RM

RM

RM

RM

RM

109 RM

RM

RM

RM

RM

RM

RM

114A

RM

RM

RM

136A

RM

RM

RM

RM

133 RM

RM

RM

RM

RM

R M

2A

RM

RM

RM

RM

RM

120A

RM

RM

RM

R M

2 22 2

R M

1 1

2 2

2" C, 2-#12 AWG,

1-#12 GRD

2" C, 2-#12 AWG,

1-#12 GRD

2" C, 2-#12 AWG,

1-#12 GRD

2" C, 2-#12 AWG,

1-#12 GRD

2" C, 2-#12 AWG,

1-#12 GRD

2" C, 2-#12 AWG,

1-#12 GRD

2" C, 2-#12 AWG,

1-#12 GRD

GRD SIZE OF GROUND WIRE

C CONDUIT

AWG AMERICAN WIRE GAUGE

1 1/2" C, 3-#6 AWG,

1-#10 GRD

93/4" C, 3-#10 AWG,

1-#10 GRD

7a

7c 1 1/2" C, 3-#2 AWG, 1-#8 GRD

EMERGENCY LIGHTS WALLPACK

EMERGENCY EXIT SIGN/LIGHTS COMBO

7b 7d

1 1/2" C, 3-#6 AWG,

1-#10 GRD

1" C, 3-#6 AWG,

1-#10 GRD

3/4" C, 3-#10 AWG,

1-#10 GRD

1 1/2" C, 3-#6 AWG,

1-#10 GRD

1 1/2" C, 3-#6 AWG,

1-#10 GRD

2 1/2" C, 3-#4

0 AWG,

1-#4 GRD

3/4" C, 3-#10 AWG,

1-#10 GRD

3/4" C, 3-#10 AWG,

1-#10 GRD

APPLETON RECEPTACLE

8a

1 1/2" C, 3-#6 AWG,

1-#10 GRD

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ANSI D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

CESAR LIMON

C.LIMON

HOWARD GUION

RAFAEL H. ACOSTA

WS-1550-2021-E-04

ELECTRI CAL LAYOUT

BUILDING 1550

4 05

FOR EMERGENCY LIGHTING,

600 V RECEPTACLES,

AND 75 KVA DRY TYPE

TRANSFORMER

D

E

S

I

G

N

B

I

D

S

E

T

GENERAL NOTES

KEYED NOTES

NOTES:

ALL GROUNDS FOR EQUIPMENT, BONDING,

AND NEUTRALS SHALL BE SIZED ACCORDING TO

NEC 2017 ARTICLE 250 AND CONTRACTOR SHALL

CHECK THE ROTATION OF THE PHASES TO BE CLOCKWISE.

EMERGENCY LIGHTING SHALL ALSO BE ACCOMPLISHED IN

ACCORDANCE WITH THE REQUIREMENTS UNDER NFPA 101

CHAPTER 40 PARAGRAPH 40.2.9 FOR THE EMERGENCY

LIGHTING AND THE EXIT SIGNS FALL UNDER PARAGRAPH

7.10.1.2.1 AND OF THE TECHNICAL REQUIREMENTS OF THE

SCOPE OF WORK. INSTALLATION SHALL COMPLY

WITH UFC 3-530-01 SECTION 2-7.1 EMERGENCY

LIGHTING, SECTION 2-7.2 EXIT SIGNS, SECTION 2-7.2

EXIT SIGNS, AND SECTION B-7 EMERGENCY AND

EXIT LIGHTING AND NEC 2020 ARTICLES 210.19 (A),

250, 300.5, 300.10 (E & H), 700.12 (A), 700.15, 700.16, 700.17, AND 700.12. CONDUIT INSTALLATION SHALL

COMPLY WITH UFC 3-520-01 SECTIONS 3-6.2 AND

PANELBOARD SECTIONS 3-2.5.1 AND 3-2.5.2.

SEE SHEET 5 (WS-1550-2021-G-05).

1. THIS PROJECT IS TO BE DONE IN BUILDING 1550. IT IS THE

CONTRACTORS RESPONSIBILITY TO PERFORM

ABATEMENT AS SPECIFIED IN THE STATEMENT OF WORK.

2. THE CONTRACTOR SHALL KEEP THE WORK AREA CLEAR

OF ANY CONSTRUCTION DEBRIS AT ALL ALL DEBRIS

GENERATED BY THIS PROJECT SHALL BE PROPERLY

DISPOSED OF OFF POST. CONTRACTOR SHALL

COORDINATE WITH THE COR TO INFORM THE BUILDING

TENANT TO MOVE ANY OF THEIR PROPERTY WITHIN 5

DAYS IN ADVANCE FOR WORK WILL BEGIN.

3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH

ALL APPLICABLE FEDERAL, STATE, AND LOCAL

REQUIREMENTS. IN ADDITION ALL WORK MUST COMPLY

WITH THE REGULATORY STANDARDS OF THE NATIONAL

FIRE PROTECTION AGENCY, NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION AND THE AMERICAN

SOCIETY OF TESTING AND MATERIALS. IT SHALL ALSO BE

ACCOMPLISHED IN ACCORDANCE WITH THE

REQUIREMENTS UNDER NFPA 101 CHAPTER 40 PARAGRAPH

40.2.9 FOR THE EMERGENCY LIGHTING AND THE EXIT

SIGNS FALL UNDER PARAGRAPH 7.10.1.2.1 AND OF THE

TECHNICAL REQUIREMENTS OF THE SCOPE OF WORK.

INSTALLATION SHALL COMPLY WITH UFC 3-530-01 SECTION

2-7.1 EMERGENCY LIGHTING, SECTION 2-7.2 EXIT SIGNS,

SECTION 2-7.2 EXIT SIGNS, AND SECTION B-7 EMERGENCY

AND EXIT LIGHTING AND NEC 2020 ARTICLES 250, 300.5,

300.10 (E & H), 700.12 (A), 700.15, 700.16, 700.17, AND 700.12.

CONTRACTOR SHALL VERIFY ALL THREE PHASE

EQUIPMENT INSTALLED THAT THEY ARE IN CLOCK WISE

ROTATION.

4. THE LIGHT SWITCH TO EMERGENCY BATTERY BACKUP

FIXTURE AND WALL PACK IS A SEPARATE

CIRCUIT. ALL EMERGENCY "EXIT" SIGNS/LIGHTS AND

WALL PACKS SHALL BE HARDWIRED. ALL NEW CONDUIT

SHALL BE RIGID AND NEW CONDUCTORS SHALL BE WIRE

TYPE THHN, 600 V RATED, AND COPPER STRANDED FOR

ALL EMERGENCY "EXIT" SIGNS/ LIGHTS AND WALL PACKS

TO INCLUDE NEUTRALS, AND GROUNDS. CONDUIT SHALL .

BE SURFACE MOUNTED OR INSIDE WALLS, ABOVE

CEILING. CONCEAL MOST OF THE CONDUIT ABOVE AND

BELOW CEILINGS WHEREVER POSSIBLE AND

TIGHTEN ALL CONDUIT SECURE. EXPOSURE OF CONDUIT

IS ALLOWED IN AREAS WHERE IS OPEN CEILING OR CMU

WALLS. SEAL ALL PENETRATIONS AND IF NECESSARY

APPLY PAINT AS NEEDED WHERE AREAS ARE SCRATCHED

ON THE WALL RESULTING FROM THE WORK THAT IS

BEING PERFORMED.

1 7/23/2021

CLARIFYING FOR THE CONTRACTOR WHO IS RESPONSIBLE TO MOVE THE CML

2 7/23/2021 ANSWERS RFI QUESTION #2. CML

3 7/23/2021 ANSWERS RFI QUESTION #3. CML

GOVERNMENTS PROPERTY.

07/23/21

MECHANICAL ROOM

DESIGNED

CHIEF, ENGINEERING DIVISION

DATE

APPROVED

RECOMMENDED

BRANCH CHIEF

SUBMITTED

PROJECT MANAGER

CHECKED

DRAWN BY

NO. DATE

DRAWING NUMBER

SCALE

SHEET OF

SHEET

DESCRIPTION

REVISIONS

APPROVEDBY

SHEET SIZE

ANSI D

DRAWING TITLE

WHITE SANDS MISSILE RANGE, NEW MEXICO

DIRECTORATE OF PUBLIC WORKS

ENGINEERING SERVICES DIVISION

CESAR LIMON

C.LIMON

HOWARD GUION

RAFAEL H. ACOSTA

WS-1550-2021-G-04

5 05

D

E

S

I

G

N

B

I

D

S

E

T

BUILDING 1550

FOR EMERGENCY LIGHTING,

AND 75 KVA DRY TYPE

TRANSFORMER

600 V RECEPTACLES

KEY NOTES ELECTRICAL LAYOUT

CONTRACTOR SHALL INSTALL (1 PER ROOM INDICATED-102, 113, 116, 136, 130, 131, 122, 120A, AND 120) THE

EMERGENCY "EXIT" SIGN/LIGHTS. THIS BUILDING REQUIRES TO INSTALL TEN (10) EXIT SIGN/LIGHTS TO BE

MOUNTED ON THE WALL WITH THE ARROW POINTING TO THE DOOR, SINGLE FACE, MOUNTED ON THE WALL

GRID AND MONOCHROMATIC LED AND WHITE LED TWIN REMOTE HEADS ALONG WITH 90 MINUTES OF

BATTERY. WHITE HOUSING AND HIGH OUTPUT OF NI CAD BATTERY.

CONTRACTOR SHALL INSTALL (1 PER ROOM INDICATED-103, 104, 105, 106, 114, 114A, 115, 117, 118, 119, 136A, 129, 127, 126, 125, 123, 124, AND 121) AND THE BAY AS WELL WITH WALL PACK EMERGENCY LIGHTS THIS

BUILDING REQUIRES TO INSTALL TWENTY FIVE WALL PACK LIGHTS MOUNTED ON THE WALL AS SHOWN IN

BUILDING LAYOUT. BASIS FOR THE DESIGN IS A INTEGRATED 2 WHITE LEDS RATED AT 3-WATT AND FOR

EACH TO HAVE A LIFE OF 10 YEARS. A SINGLE FIXTURE TO ILLUMINATE 42 FEET LONG 6 FEET WIDE PATH OF

EGRESS AT ABOUT 12 FOOT MOUNTING HEIGHT ALONG WITH 90 MINUTES OF BATTERY LIFE. HIGH OUTPUT

OF NI CAD BATTERY.

INSTALL THE FOLLOWING:

· BY WALL MOUNTING FIVE NEW 600 V, 100 AMP, NEMA 1, 3 PHASE FUSE HEAVY DUTY FUSE SAFETY

DISCONNECT SWITCHES TO INCLUDE 15-50 AMP DUAL ELEMENT TIME DELAY FUSES

· INSTALL BY WALL MOUNTING 5 APPLETON RECEPTACLES TO INCLUDE FOR EACH AJA MOUNTING BOX

AND CLAMPING RING PLUG (MANUFACTURES #: ADJA1044-150 AND ACP1044CD) OR APPROVED

EQUIVALENT.

· INSTALL 5-60 AMP 3 POLE, 240 V CIRCUIT BREAKERS AT EXISTING PANELS #2, #10, AND #11. RUN 120 FT

OF 1 1/2" EMT CONDUIT TO INCLUDE #6 AWG (#10 GROUND), THHN, COPPER STRANDED.

EXISTING PANEL "2"-3 PHASE, 100 AMP, 208 / 120 V -THERE ARE 7-20 AMP SINGLE POLE SPARE BREAKER AT

#41 THRU 54 FOR CONTRACTOR SHALL RUN

" EMT CONDUIT 150 FEET TO INCLUDE #12 WIRE (NEUTRAL AND

GROUND SHALL BE THE SAME SIZE) THHN, COPPER STRANDED TO PROVIDE POWER FOR EMERGENCY

LIGHTING .

EXISTING PANEL "1"-3 PHASE, 225 AMP, 208 / 120 V -THERE ARE 5-20 AMP SINGLE POLE SPARE BREAKERS AT

#28 THRU 42 FOR CONTRACTOR SHALL RUN

" EMT CONDUIT150 FEET TO INCLUDE #12 WIRE (NEUTRAL AND

GROUND SHALL BE THE SAME SIZE) THHN, COPPER STRANDED TO PROVIDE POWER FOR EMERGENCY

LIGHTING .

EXISTING PANEL "10"-3 PHASE, 100 AMP, 208 / 120 V -THERE ARE BLANK CIRCUITS FOR ADDING A 1-20 AMP

SINGLE POLE BREAKER AT SPACE #29 FOR CONTRACTOR SHALL RUN

" EMT CONDUIT 150 FEET TO

INLCLUDE #12 WIRE (NEUTRAL AND GROUND SHALL BE THE SAME SIZE)THHN, COPPER STRANDED TO

PROVIDE POWER FOR EMERGENCY LIGHTING (SPACES #31 THRU #35) .

EXISTING PANEL "MECH ROOM"-3 PHASE, 225 AMP, 208 / 120 V -THERE ARE 5-20 AMP SINGLE POLE SPARE

BREAKER AT #33 THRU 39 FOR CONTRACTOR SHALL RUN

" EMT CONDUIT 100 FEET TO INCLUDE #12 WIRE

(NEUTRAL AND GROUND SHALL BE THE SAME TO PROVIDE POWER FOR EMERGENCY LIGHTING.

INSTALL NEW 480 V IN MECHANICAL ROOM , 3 PHASE PANEL, SURFACE MOUNTED 225 AMP MAIN BREAKER, 3

PHASE , COPPER BUSS, WITH 40 SPACES, AND NEMA 1. ALL BREAKERS SHALL BE BOLT ONTO THE COPPER

BUS. LABEL THE 3 FEEDS AND WIRES TO ALL THE CIRCUIT DESIGNATIONS.

INSTALL 1 WALL MOUNTED HEAVY DUTY FUSE DISCONNECT SWITCH, NEMA 3R, 400AMP,

240 VAC, 3 POLE, INCLUDE 3-300 AMP DUAL ELEMENT TIME DELAY FUSES.

INSTALL 1-75 KVA DRY TYPE STEP UP 3 PHASE TRANSFORMER IN MECHANICAL ROOM, MANUFACTURE

POWER SMITH OR APPROVED EQUIVALENT, 208 / 480 V, COPPER WINDINGS, TO COMPLY WITH ENERGY HIGH

EFFICIENCY STANDARDS 2016 DEPARTMENT OF ENERGY FOR DISTRIBUTION TRANSFORMERS, AND NEMA 2.

TRANSFORMER MUST BE LEVELED AND ANCHORED TO CONCRETE.

· FOR THE PRIMARY RUN 30 FEET OF 2

" RIGID CONDUIT INCLUDE 3-#4/0 AWG, THHN, COPPER (INCLUDE

A #4 AWG EQUIPMENT GROUND) TO TIE INTO EXISTING OUTSIDE 300 KVA PADMOUNT TRANSFORMER.

FOR

· THE SECONDARY RUN 10 FEET OF 1 1/2" LIQUID TIGHT METALLIC FLEXIBLE CONDUIT TO INCLUDE 3-#1

AWG CONDUCTORS (INCLUDE A #4 AWG EQUIPMENT GROUND) TO THE NEW 480 V, 3 PHASE PANEL).

EXISTING 300 KVA, PADMOUNT 3 PHASE TRANSFORMER, PRIMARY: 12.47 KV, SECONDARY: 208V.

PANEL "1"-3 PHASE, 100 AMP, 208 / 120 V -THERE ARE 5-20 AMP BREAKER AT SPARES #34 THRU #42 FOR

CONTRACTOR SHALL RUN

" EMT CONDUIT 150 FEET TO INCLUDE #12 WIRE (NEUTRAL AND GROUND SHALL

BE THE SAME SIZE) TO PROVIDE POWER FOR EMERGENCY LIGHTING. INSTALL 2-20 AMP SINGLE POLE

BREAKERS.

PANEL "11"-3 PHASE, 100 AMP, 208 / 120 V -THERE ARE SPACES #29 THRU #41 FOR CONTRACTOR SHALL RUN

200 FEET

" EMT CONDUIT TO INCLUDE #12 WIRE (NEUTRAL AND GROUND SHALL BE THE SAME SIZE) AND

TO PROVIDE POWER FOR EMERGENCY LIGHTING. INSTALL 2-20 AMP SINGLE POLE BREAKERS.

RUN 20 FEET OF 3/4" EMT CONDUIT WITH 3-#12 AWG THHN CONDUCTORS, 1-#12 AWG FOR EQUIPMENT

GROUND, COPPER STRANDED TO THE EXISTING 480V, 3 PHASE COMPRESSOR IN MECHANICAL ROOM AND

INSTALL 1-20 AMP, 3 POLE BREAKER TO NEW 480 V PANEL LISTED IN KEY NOTE 7a. CONTRACTOR SHALL

TERMINATE CONDUCTORS TO EXISTING FUSE DISCONNECT BUT ARE NOT RESPONSIBLE TO TURN ON

COMPRESSOR OR REPAIR.

COMPRESSOR NAMEPLATE:

BALDOR RELIANCED SUPER E MOTOR

CAT NO: EM3218T

SPEC: 35G548S270G1 HZ: 60 PH: 3 PF: 80 V: 230 / 460 V 13.2 / 6.6 AMPS

INSTALL BY WALL MOUNTING 2-30 AMP HUBBELL WELDING RECEPTACLES MANUFACTURE #HBL2731 OR

APPROVED EQUIVALENT TO INCLUDE THE FOLLOWING:

· 2-MECHANICAL INTERLOCK (TWIST LOCK) DEVICE, WITH PIN AND SLEEVE, INSULGRIP, FUSED

(INCLUDE-6-30 AMP DUAL ELEMENT TIME DELAY FUSES), 600 V AC/ 250 VDC VOLTAGE FOR EACH

RECEPTACLE.

· RUN 100 FEET OF 3/4" EMT CONDUIT TO INCLUDE 3-#10 AWG (INCLUDE 1-#10 AWG EQUIPMENT GROUND

CONDUCTOR), THHN, COPPER STRANDED AND INSTALL 2-30 AMP, 3 POLE, BREAKERS IN NEW 480V 3

PHASE PANEL LISTED IN KEY NOTE 7a.

KEYED NOTES

7a

7b

7c

7d

8a

7/23/2021 THE APPLETON CONNECTORS SHALL BE WIRED TO THE EXISTING 3 PHASE. CML

208 V PANELS.

7/23/2021

ANSWERING RFI QUESTION #3.

CML2

7/23/2021 CML3

THE DRY TYPE TRANSFORMER SHALL BE RATED AT 75 KVA.

ANSWERING RFI QUESTION #1.7/23/2021 CML4

07/23/21

Sheets and Views
WTD052870P- PLANS AND DRAWINGS- ECEMBER 2020 -BID SET 100% Design Building 1550 Emergency Lights Installation, KVA DRY TYPE TRANSFORMER, 480 V THREE DISTRIBUTION PANEL, AND 600 V RATED RECEPTACLES-COVER SHEET
WTD052870P- PLANS AND DRAWINGS- ECEMBER 2020 -BID SET 100% Design Building 1550 Emergency Lights Installation, KVA DRY TYPE TRANSFORMER, 480 V THREE DISTRIBUTION PANEL, AND 600 V RATED RECEPTACLES-COVER SHEET (2)
WTD052870P- PLANS AND DRAWINGS- ECEMBER 2020 -BID SET 100% Design Building 1550 Emergency Lights Installation, KVA DRY TYPE TRANSFORMER, 480 V THREE DISTRIBUTION PANEL, AND 600 V RATED RECEPTACLES-Sheet 2
WTD052870P- PLANS AND DRAWINGS- ECEMBER 2020 -BID SET 100% Design Building 1550 Emergency Lights Installation, KVA DRY TYPE TRANSFORMER, 480 V THREE DISTRIBUTION PANEL, AND 600 V RATED RECEPTACLES-Sheet 2 (2)
WTD052870P- PLANS AND DRAWINGS- ECEMBER 2020 -BID SET 100% Design Building 1550 Emergency Lights Installation, KVA DRY TYPE TRANSFORMER, 480 V THREE DISTRIBUTION PANEL, AND 600 V RATED RECEPTACLES-Sheet 2 (3)