inspection results

STEWS-NRS-ER

MEMORANDUM FOR RECORD

SUBJECT: Inspection Results

8 Sept 98

1. Reference work order DP P032 8 P 01, 02 to inspect building 1316 for asbestos and lead-based paint prior to removal of the carpet, tile and mastic , renovation of the rest rooms and removal/replacement of the dropped ceiling .

2. An inspection of the work area and scope of work was performed by Mr. Trujillo of the Regulatory/Codes Enforcement Branch, NRS-ER .

3. Samples of the floor tile and mastic were sent to an accredited laboratory for asbestos analysis. The sample results show the floor tile does not contain asbestos , the mastic does contain asbestos .

4. Due to the floor tile mastic containing asbestos , the carpet, floor tile and mastic must be removed by a certified asbestos abatement team.

5. The ceiling tile does not contain asbestos .

6. Asbestos and lead-based clearances are granted for replacement of the ceiling, resurfacing of the gym floor and renovation of the rest rooms .

7. The white mastic on the duct work above the ceiling contains asbestos , do not remove the duct work or white mastic during the removal of the face diffusers.

8. Asbestos and lead-based paint clearances are granted for demolition of the CMU walls, ceiling plaster , wall cabinets and counter tops, accordion partitions and cut out an opening for a window in the gym interior wall .

9. Contact this office at 678-7049 if there are any changes in the scope of work.

JOE TALAMANTES

Inspector , NRS-ER