This document contains questions and answers from potential bidders for federal contract number W911SA23B2002 to repair Building 2660 at Fort McCoy, Wisconsin. Key specifications require blast resistant glazing, windows, doors, and frames per UFC 4-010-01 standards. The sewer line exits the back of the building and ties into an existing main located off site. Furnace and HVAC equipment specifications allow flexibility. The enthalpy wheel must be utilized as scheduled. Suspended acoustical ceiling tiles and fiber reinforced plastic panel manufacturers are approved for the base bid. The substantial completion date was not provided to bidders.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions from potential bidders for W911SA23B2002 – Repair B2660 to Support MFGI
- Spec section 08 80 00 part 2, 2.01, B 7 states Blast resistant glazing at exterior windows and doors shall be as required by UFC 4-010-01, standard 10. Spec section 08 53 00 vinyl clad double-hung window spec does NOT require UFC blast resistant nor does 08 12 00 steel frames nor 08 13 13 steel doors.
Is blast resistant glazing required in non-blast frames, doors, and windows?
Specification 08 80 00 GLAZING states UFC 4-010-01 (Minimum Anti-terrorism Standards for Buildings) applies.
Specification 08 53 00 VINYL CLAD DOUBLE-HUNG WOOD WINDOWS (contrary to the Bidders comment) states at paragraph 2.01B.1.g. that UFC 4-010-01 applies.
Specification 08 13 13 STANDARD STEEL DOORS is mute on Glazing type, so Specification 08 80 00 dictates Glazing to be used.
The Drawings at Sheet A1.4, Details 4, 5, and 6 only state “Vinyl Double Hung Window” so the Specification 08 53 00 is not contradicted and applies.
Therefore, Glazing per UFC 2-010-01, Standard 10 and Appendix B is required. The same UFC states that Doors shall use Standard 10 if said door incorporates Glazing.
Per UFC 4-010-0 paragraph B-3.1.1 “Window frames constructed from materials other than aluminum or steel should be tested in accordance with paragraph B-3.1.2 or proven by analysis to demonstrate performance equivalent to or better than the hazard rating associated with the applicable level of protection as indicated in Table B-1.”, and any submitted Window Systems will be held to this requirement.
- On Plan Page P1.1, Sheet 15, Note P6 states Replace entire sewer from building through yard to existing sewer main. My question where is the main located, will we need to go into a street? How deep is the sewer we are tying into? Per drawing the sewer is exiting the back of the building.
Answer: Please find attached two maps. One is per request for sewer line, and an additional map for other utilities.
- #1 The furnace calls for a mystery unit with 60 input and 59 output and 3 stages downflow. The specs call for a two stage up flow.
Answer: Two stage furnace shall be acceptable.
- #2 The AC schedule calls for a 16 seer ac with cased N coil and has some remarks listed, but no codes entered in the table? The specs call for an up flow two stage AC with a Cased A coil?
Answer: Cased A coil is for evaporator on indoor unit. ACCU schedule applies to outdoor unit.
- #3 For the ERV, they schedule the Greenheck wheel, but the specs say plate HX.
Answer: Utilize enthalpy wheel as scheduled.
- Section 095110, Suspended Acoustical Ceilings, 2.02 lists the specifications needed for ACT-1 and ACT-2.
USG Radar #2210 and Sheetrock Gypsum Lay-In #3260 match these specifications.
Would these USG ceiling tiles be approved for base bid?
Answer: USG Tiles would be acceptable for bid.
- Section 097813, Fiber Reinforced Plastic, 2.01.A specifies the FRP needed as white and pebbled.
Are you needing the FRP to be Class C (standard) or Class A (fire rated)?
Answer: The FRP does not need to be Fire Rated.
- Would Glasteel and/or Nudo be approved manufacturers to bid?
Answer: Glasteel and/or Nudo would be acceptable for bid.
- Additionally, do you know the substantial completion date?
Response: I am unable to answer this question.
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S
S S
S S
S S
S S
S
West G Street
W es t R eg im en ta l A ve
W es t T we lft h
Av e
PL26N
PL26I
PL26I
PL26K
PL26M
PL26L
PL26L
CUI
CUI
Controlled by: Fort McCoy, WI Controlled by: Directorate of Public Works/Master Planning Division
CUI Category: Critical infrastructure & OPSEC Distribution Statement/Limited Dissemination: FEDCON
POC: Scott Wenzlaff, 608-388-5478
Legend S Wastewater Main - 8 ft Depth
S S Wastewater Service - 8 ft Depth
W
W
W
W
W
W
W
W
W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W W
W
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S
S S
S S
S S
S S
S
E E
E E
E E
E E
E E
E E
E E
E
E E
E
E E
E E
E E
E E
E
E
E
E
E
E
E
E
G
G G
G
G
G
G
G G
G G
G G
G G
G G
G G
G G
G G
G G
G G
G
West G Street
W es t R eg im en ta l A ve
W es t T we lft h
Av e
PL26N
PL26I
PL26I
PL26K
PL26M
PL26L
PL26L
CUI
CUI
Controlled by: Fort McCoy, WI Controlled by: Directorate of Public Works/Master Planning Division
CUI Category: Critical infrastructure & OPSEC Distribution Statement/Limited Dissemination: FEDCON
POC: Scott Wenzlaff, 608-388-5478
Legend S Wastewater Main
S S Wastewater Service
Comm Line
G GMain Line
G G Service Line
# #E Secondary Overhead Line Segment, Electrical
S Wastewater Main
S S Wastewater Service
W W W Water Main W Water Service
USG RADAR™ ACOUSTICAL PANELS
CLIMAPLUS™ PERFORMANCE
USG Radar™ Acoustical Panels with ClimaPlus™ Performance/
USG Donn® Brand DX®/DXL™ Acoustical Suspension System
FEATURES AND BENEFITS
• Nondirectional pattern.
• High-durability panels are 55% more durable than standard panels.
• USDA Certifi ed Biobased Product.12
• ClimaPlus™ 30-year limited system warranty against visible sag, mold and mildew.
• Optional Firecode® product designed to meet life-safety codes.
APPLICATIONS
• Schools
• Corridors
• Lobby areas
• O� ces
• Retail stores
SUBSTRATE
• Wet-formed mineral fi ber
TO ORDER SAMPLES, GO TO USG.COM OR CGCINC.COM
STANDARD COLORS
Flat White
Parchment
Manila
Straw
Sandstone
Taupe
Charcoal
Flat Black
ADVANTAGE COLORS
Beige
Silvertone
Mist
Li gh tly T ex tu re d
Pa ne l
USG
Ceiling Solutions item # 2210
NathanYelle Highlight
SC2127/rev. 11-16 © 2016 USG Corporation and/or its a� liates. All rights reserved.
Printed in U.S.A.
Manufactured by USG Interiors, LLC 550 West Adams Street Chicago, IL 60661
YEAR LIMITED SYSTEM
WARRANTY
• No Visible Sag
• Mold/Mildew Protection
YEAR
AVAILABILITY
2210, 2215, 2220, 2225, 2230, 2410, HIGH RECYCLED
CONTENT
Notice The information in this document is subject to change without notice.
CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document.
ORDER SAMPLES/LITERATURE
USG: samplit@usg.com fax: 888 874-2348 | usg.com CGC: contact Sales Representative
TECHNICAL SERVICES
800 USG.4YOU (874-4968)
FOR MOST UP-TO-DATE
TECHNICAL INFORMATION
AND LEED REPORT TOOL
usgdesignstudio.com cgcdesignstudio.com
PRODUCT CERTIFIED
FOR LOW CHEMICAL
EMISSIONS:
UL.COM/GG
UL 2818
USG RADAR™ ACOUSTICAL PANELS
CLIMAPLUS™ PERFORMANCE
UL Classifi ed
Edge Panel Size Imperial Metric (mm)
Fire Rating2
Item No.
Imperial Metric (mm)
NRC CAC
Min.
LR3 Color 5,6 Grid Options
VOC
Emissions
Anti-Mold & Mildew/Sag Resistance
Abuse Resistant
Recycled Content1
Panel Cost
USG RADAR™ PANELS SQ 2'x2'x5/8" Class A 2210 0.55 33 0.84 White, Standard Beige, Mist, Silvertone
A,B, J Low 25-34% $
2'x2'x5/8" 2215 0.55 35 0.84 White A Low 48-51% $
2'x4'x5/8" 600x1200x15
Class A 2410
ME2410
0.55 35 0.84 White, Standard Beige, Mist, Silvertone
A, J Low 25-34% $
2'x4'x5/8" 2415 0.55 35 0.84 White A Low 48-51% $
2'x4'x5/8" Class A 2410P7 0.55 35 0.85 White A, J Low 25-34% $
SLT 2'x2'x5/8" 600x600x15
Class A 2220
ME2220
0.55 33 0.84 White, Standard Beige, Mist, Silvertone (Flat Black or Charcoal Not Available)
C Low 25-34% $
2'x2'x5/8" 2225 0.55 35 0.84 White C Low 51-59%10 $
2'x4'x5/8" Class A 2420 0.55 35 0.84 White C Low 25-34% $
2'x4'x5/8" 2425 0.55 35 0.84 White C Low 51-59%10 $
FLB 2'x2'x5/8" Class A 2230 0.55 33 0.84 White D,F,G,I Low 26-34% $
2'x2'x5/8" 2235 0.55 35 0.84 White E,H Low 51-59%10 $
USG RADAR™
HIGH-DURABILITY
PANELS
SQ 2'x2'x5/8" Class A 2207 0.55 35 0.84 White A,B, J Low 42% $
2'x4'x5/8" Class A 2407 0.55 35 0.84 White A, J Low 42% $
SLT 2'x2'x5/8" Class A 2227 0.55 35 0.84 White C Low 42% $
USG RADAR™ TILE8,9 SF 12'x12'x5/8" Class A 2570 0.45 35 0.84 White Adhesive Staple
Low 34-44% $$$
Low Emissions (VOC) Third party (GREENGUARD Gold) certifi ed for low-emitting performance, meets California Department of Public Health’s (CDPH) Standard Method v1.1 - 2010 (CA Section 01350). ‘Certifi cates of Compliance’ for Low VOC Emissions are available on usg.com and at productguide.ulenvironment.com.
ClimaPlus™ Warranty Performance4
Contains a broad-spectrum antimicrobial additive on the face and back of the panel that provides resistance against the growth of mold and mildew. Includes sag-resistance performance.
High Recycled Content Classifi ed as containing greater than 50% total recycled content. Total recycled content is based on product composition of postconsumer and preconsumer (postindustrial) recycled content per FTC guidelines.
Firecode®
Abuse Resistant
GRID PROFILE OPTIONS A
USG
DX®/DXL™
B 11
USG
Centricitee™
DXT™
C
USG
DX®/DXL™
D
USG
Centricitee™
DXT™
E
USG
Centricitee™
DXLT™
F
USG
Fineline®
DXF™
G
USG
Fineline® 1/8
DXFF™
H
USG
Fineline®
DXLF™
I
USG
Identitee®
DXI™
J
USG
DXW™
PHYSICAL DATA/
FOOTNOTES
Product literature Data sheet: SC2127
ASTM E1264 classifi cation Type III, Form 2, Pattern C,E
ASTM E84 and CAN/ULC S102 surface-burning characteristics Class A Flame spread: 25 or less Smoke developed: 50 or less
UL Type
FR-83
Weight 0.61–1.15 lb./sq. ft.
Online tools usgdesignstudio.com or cgcdesignstudio.com
Thermal resistance R-1.4 (5/8" Class A panels and tile) R-1.6 (Firecode® panels)
Maximum backloading See USG 30-Year Limited System Warranty Commercial Applications (SC2102).
Maintenance Can be cleaned easily with a soft brush or vacuum.
High-durability panels ASTM D1037—falling-ball impact test.
Metric sizes available Contact sales for minimum quantities and lead times.
Notes
1. For details, see LEED report tool at usgdesignstudio.com or cgcdesignstudio.com.
2. Fire-rated items: see UL design details.
3. LR values are shown as averages.
4. For details, see USG 30-Year Limited System Warranty Commercial Applications
(SC2102) and ClimaPlus™ Ceilings Certifi cation of Performance (SC2451).
5. Metric available in White only.
6. See Colors selector for more information.
7. Includes plastic coating. Gardner Scrubbability tested to 3,000 cycles (ASTM D246).
8. SF = staple fl ange.
9. Not UL Classifi ed for acoustics.
10. High recycled content not available at all plants.
11. Maximum 2'x2' with SQ edge panels.
12. This product has achieved both BioPreferred initiatives: Federal Procurement
Preference and Certifi ed Product Labeling. See the complete listing of all USG ceiling panels on biopreferred.gov website.
The trademarks USG, CGC, CENTRICITEE, CLIMAPLUS, DONN, DX, DXF, DXFF, DXI, DXL, DXLF, DXLT, DXT, DXW, FINELINE, FIRECODE, IDENTITEE, RADAR, IT’S YOUR WORLD. BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its a� liates.
Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specifi cation and installation.
kylelarson
USG SHEETROCK® BRAND LAY-IN
GYPSUM CEILING PANELS
CLIMAPLUS™ PERFORMANCE
USG Sheetrock® Brand Lay-In Gypsum Ceiling Panel with ClimaPlus™ Performance/ USG Donn® Brand ZXLA™ Acoustical
Suspension System
FEATURES AND BENEFITS
• USG Clean Room™ panels have a vinyl-laminated face with sealed back and edges for use in cleanroom environments up to Class 100/ISO 5.
• Washable and scrubbable finish–impact and scratch resistant.
• USDA Certified Biobased Product.7
• Panels meet USDA/FSIS requirements for food processing areas.
• ClimaPlus™ 30 year limited system warranty against visible sag.
APPLICATIONS
• Kitchens and food preparation areas
• Restrooms and utility areas
• Locker rooms
• Parking garages
• Exterior protected soffits
SUBSTRATE
• Gypsum panel
TO ORDER SAMPLES, GO TO USG.COM OR CGCINC.COM
Flat White
Sm oo th -T ex tu re d
Pa ne l – V in yl
USG
Ceiling Solutions
#3260
WesleySmith Highlight
WesleySmith
SC1820/rev. 8-21 © 2021 USG Corporation and/or its affiliates. All rights reserved.
Printed in USA
Manufactured by United States Gypsum Company 550 West Adams Street Chicago, IL 60661
YEAR LIMITED SYSTEM
WARRANTY
• No Visible Sag
• Mold/Mildew Protection
YEAR
AVAILABILITY
Notice The information in this document is subject to change without notice.
CGC Inc. or USG Corp. assumes no responsibility for any errors that may inadvertently appear in this document.
PRODUCT CERTIFIED
FOR LOW CHEMICAL
EMISSIONS:
UL.COM/GG
UL 2818
ORDER SAMPLES/LITERATURE
USG: samplit@usg.com phone: 866 528-7089 | usg.com CGC: contact Sales Representative
TECHNICAL SERVICES
800 USG.4YOU (874-4968)
FOR MOST UP-TO-DATE
TECHNICAL INFORMATION
AND LEED REPORT TOOL
usgdesignstudio.com cgcdesignstudio.com
Edge Panel Size Fire Rating2 Item No. NRC4 CAC Min.
LR3 Color Abuse Resistant
Grid Options VOC Emissions
Recycled Content1
Panel Cost
USG SHEETROCK® BRAND
LAY-IN CEILING PANEL
SQ 2'x2'x1/2" 3260 – 35 0.77 White A,B,C,D Low 17.8% $
2'x4'x1/2" 3270 – 40 0.77 White A,B,C,D Low 17.8% $
USG SHEETROCK® BRAND
LAY-IN CEILING
PANEL CLEAN ROOM™ 5
SQ 2'x4'x1/2" 3200 – 40 0.77 White A,B,C,D Low 17.8% $$
Low Emissions (VOC) Third party (GREENGUARD Gold) certified for low-emitting performance, meets California
Department of Public Health’s (CDPH) Standard Method v1.2 - 2017 (CA Section 01350). ‘Certificates of Compliance’ for Low VOC Emissions are available on usg.com and at spot.ul.com.
Firecode®
Abuse Resistant
GRID PROFILE OPTIONS A
USG DXL™
B
USG DXLA™
C
USG ZXLA™
D6
USG CE™
PHYSICAL DATA/
FOOTNOTES
Product literature Data sheet: SC1820
ASTM E1264 classification Type XX, Pattern G
ASTM E84 and CAN/ULC S102 surface-burning characteristics Class A Flame spread: 25 or less Smoke developed: 50 or less
UL Type
FC-CB
Weight 1/2" = 2.00 lb./sq. ft.
Online tools usgdesignstudio.com or cgcdesignstudio.com
Thermal resistance 1/2" = R-0.45
Maximum backloading See USG 30-Year Limited System Warranty Commercial Applications (SC2102).
Maintenance Can be cleaned easily with a damp sponge. Use mild deter gent and water—do not use acetate, ammonia or high concentration of chlorine, bromide or other harsh chemicals.
Application considerations Product is directional. Install with all manufactured edges parallel and in the same direction.
Notes
1. For details, see USG Sustainability tool at usgdesignstudio.com or cgcdesignstudio.com.
2. Fire-rated items: see UL design details.
3. LR values are shown as averages.
4. NRC rating is 0.10. USG does not consider a ceiling panel to be acoustically rated if NRC is less than 0.50.
5. Field-cut edges of USG Clean Room™ panels must be sealed with white latex paint.
6. Clean Room-rated applications require a suspension system with gasketed tee flanges such as USG Donn® Brand CE™.
7. This product has achieved both BioPreferred initiatives: Federal Procurement Preference and Certified Product Labeling. See the complete listing of all USG ceiling panels on biopreferred.gov website.
USG SHEETROCK® BRAND LAY-IN
GYPSUM CEILING PANELS
CLIMAPLUS™ PERFORMANCE
The trademarks USG, CGC, CE, CLEAN ROOM, CLIMAPLUS, DONN, DXL, DXLA, FIRECODE, SHEETROCK, ZXLA, IT'S YOUR WORLD.
BUILD IT., the USG/CGC logo, the design elements and colors, and related marks are trademarks of USG Corporation or its affiliates.
Safety First! Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read SDS and literature before specification and installation.
dougscieszinski Highlight dougscieszinski Highlight dougscieszinski Highlight dougscieszinski Highlight
WesleySmith
A
LL
C
EI
LI
N
G L
IN
ER
P A
N
EL
S
800-238-5546 www.glasteel.com
WALL & CEILING LINER PANELS
Quality, commitment and innovation Glasteel, with more than 50 years of experience, is one of the largest manufacturers of Fiberglass Reinforced Panels in the North American Market supported by three state-of-the-art manufacturing plants (all ISO 9001:2008 Certified) and three strategically located distribution centers. Our mission is to offer added value products with the highest quality standards, competitive pricing and best customer service of the industry.
Glasliner FRP meets many of today’s demanding applications that require high sanitation needs.
These applications range from restaurants and supermarkets to restrooms and storage areas.
Glasteel’s process uses a special type of high strength polyester resin combined with fiberglass reinforcement to produce liner panels offering superior quality and durability. The result is a panel with a resin rich surface that is tough, strong and easy to clean.
Wall & Ceiling Liner Panels
The Best Products, Service, Price & Selection All Under One Brand
Resin rich surfaces that are tough, strong and easy to clean.
Maximum Sanitation Protection
• Meets USDA Standards
• Maximum sanitation protection
• Significant cost savings over other materials
Excellent Quality
• Years of dependable performance
• Resin rich surface that is tough & easy to clean
• Meets today’s high sanitation standards
Highly Impact Resistant
• Extremely high strength to weight ratio
• Tough surface that resists shattering, scratches and abrasions
Outstanding Cleanability
• Cleans with regular detergents and water
Wall Panels
Moisture Resistant
• Does not support mold or mildew
• Will not rust or corrode
800-238-5546 www.glasteel.com
Series Nominal Thickness 1600 .120” 1200 .090” 180 .060” 160 .045” 150 .035”
Width Standard 4 Feet Length 8, 9, 10 and 12 Feet
Glasliner FRP is available in the following sizes:
Wall Panel Specifications
Low Cost Installation
• Easy to handle and install in any type of construction, and over any type of existing wall surface
• No special tools needed
• More economical than stainless steel or ceramic tile
Superior Flexibility
• Panels are flexible enough to lay flat, allowing a better fit into areas with close tolerance seams
Custom Designed Liner Panels
• Available in 5 different standard panel thicknesses
• Shipped in standard 4 foot width and in
8, 9, 10 and 12 foot lengths
Improved Chemical Resistance
• Resists stains
• Rust proof - will not corrode
• Minimum maintenance and never needs painting
Wall Panels
Approvals & Certifications
• ISO 9001:2008: All Glasteel plants are ISO 9001:2008 Certified
• Meets USDA/FSIS requirements
• Canadian Food Inspection Agency
(CFIA) accepted
• ASTM: All Glasliner FRP liner panels are manufactured according to industry standard
ASTM D-5319-2008
Storage Recommendations
• Store panels indoors in a cool, dry, well-ventilated area
• Panels should be stacked on skids not more than 5 skids high
• Do not allow moisture to collect on or in-between panels
Typical Physical Properties for .090” Contractor Grade
Property Test
Method Unit
Flexural Strength ASTM D-790
Glasteel Class C General Purpose
Result
Glasteel Class A Fire Retardant
Result
PSI 17,000 10,000
Flexural Modulus
ASTM
D-790 PSI 6.0 x 105 3.1 x 105
Tensile Strength
ASTM
D-638 PSI 8,000 7,000
Tensile Modulus ASTM D-638 PSI 9.43 x 105 3.1 x 105
% Elongation ASTM D-638 % 1.20 1.80
Water Absorption 21˚C @ 72 hrs.
ASTM
D-570 % 0.17 0.72
Izod Impact Strength
ASTM
D-256 ft.-lbs.
/in. 7.0 7.16
Coef. of Linear Thermal Expansion
ASTM
D-696 in./in.
/˚F 2.22 x 10-5 2.39 x 10-5
Barcol Hardness
ASTM
D-2583 Avg. 30 35
Specific Gravity ASTM D-792 N/A 1.6138 1.5743
Abrasion Resistance TABER 0.293 0.391% WT Loss
Flash Ignition Temp. ASTM 1929 430 400˚C
Self Ignition Temp. ASTM 1929 450 430˚C
Flame Spread ASTM E-84 ≤200 ≤25N/A
Smoke Generation ASTM E-84 <450 <450N/A
800-238-5546 www.glasteel.com
• Fire Ratings: Glasliner products are available on multiple fire ratings, such as Class C (general purpose) and Class A (fire retardant).
Please contact your Glasteel representative for test results.
Safety:
• Use eye protection.
• Wear filter mask to cover nose and mouth, especially when cutting.
• Refer to our web site for recommended sealants and adhesives.
Tools Needed:
• Power or hand saw (fine tooth or carbide blade)
• Power or hand drill (carbide tip recommended)
• Carpenter’s square
• Hammer, tape measure and level
• Adhesive and notched trowel
• Silicone sealant and caulking gun
• Vinyl moldings and 3/4” nylon fasteners
• Eye and Nose/Mouth Protection
Preparation:
• It is important to store Glasliner FRP flat, on a clean, dry surface for 24 hours before installation. It is preferable to store them inside the actual area of installation or, at least, under similar climate conditions.
• Walls must be clean and free of all substances.
• Level any high or low spots on walls. Concrete block walls may require a leveling coat of plaster or other similar material.
800-238-5546 www.glasteel.com
Color Selections
Bright White Almond
Installation of FRP Panels, in any application, should be approved by local building code officials before panels are ordered. Glasteel cannot ensure local code compliance in any or all situations. NOTICE: Panels and components made of fiberglass (FRP), wood, vinyl or foam may be combustible. DISCLAIMER and LIMITATION of Liability: The information contained in this literature is presented in good faith, and is believed to be accurate and reliable at time of publication. No representation, guarantee or warranty is made as to the completeness, reliability or accuracy of this information. This also includes NO IMPLIED WARRANTY OR
MERCHANTABILITY OR FUNCTIONAL USE FOR SPECIFIC APPLICATION.
Ivory Beige
Light Gray Silver
Black
Two Surface Finishes
Traditional pebbled finish
Premium Gel Coat White Only.
Colors are Special Order.
Installation Instructions
Drilling Fastener Holes:
• Pre-drill fastener holes before applying adhesive.
• Fastener holes should be slightly oversize to allow for normal expansion and contraction.
• Drill holes no further than 8” apart and 1” from outside edge, 16” apart on intermediate and on 16” centers.
Installation reminders:
1. Follow safety and fire guidelines during installation and use of panels.
2. First panel installed should be set true with plumb line.
3. Wall must be clean and flat.
4. Use moldings, silicone, nylon rivets and adhesive for best installation.
5. Apply adhesive per manufacturer’s instructions .
6. Install panels and moldings.
7. Seal edges and moldings.
8. Remove excess silicone.
9. Clean panels after installation with light detergent.
Accessories
Inside Corner End Cap Divider Bar
Outside Corner
Outside Corner Angle
Nylon Rivets
FRP Adhesive
Applying Adhesive
• For best installation, combine adhesive and nylon fasteners.
• Glasliner FRP should never be installed on uneven walls using only adhesive.
Actual requirements may vary. Call Glasteel for complete installation instructions.
800-238-5546 www.glasteel.com
Cutting Glasliner FRP for Floor to Ceiling Heights of 8 Feet or Less:
• Subtract 1/2” from height measurement to allow for expansion.
• Allow for 1/8” expansion gap around pipes and other projections.
Allows new FRP panels to be applied over existing FRP panels
Ceiling Panel Specifications
Applications
• Food processing areas
• Restaurants
• Bathrooms
• Storage rooms
• Schools
• Hospitals
• Many other applications where sanitation is required
Characteristics
• Moisture resistant - does not support mold or mildew
• Rust proof - will not corrode
• Stain resistant
• High strength-to-weight ratio
• Easily removable for cleaning
Easy to Install
• Cut to size for easy installation
• Lightweight and easy to handle
Minimal Deflection
• Panel formulation makes for a strong, rigid ceiling panel
Sizes 23 3/4” x 23 3/4” 23 3/4” x 47 3/4”
Thickness 0.100” Finishes Textured or Smooth Color Standard Colors Sag Tolerance < .25”
Fire Rating
• Class C: General Purpose
• Class A: Fire Retardant
Ceiling Panels
Glasliner can be installed directly to solid walls or over insulation. As an extra barrier of protection against moisture and insects, Glasliner also traps in the energy used to heat and cool your home.
Division Bar
Inside Corner Angle
1 1/4” x 1 1/4”
Nylon Rivets 1/4” Plastic
Pins Available up to 2”
Outside Corner Angle
1 1/4” x 1 1/4”
*Savings from insulated foundations vary with fuel prices, heating equipment, performance, and climate.
Recommended Accessories esuoH dnuorG noitadnuoF esuoH dnuorG noitadnuoF
Glasliner Foundation Liner
Without Glasliner Foundation Liner
With Glasliner Foundation Liner
Sizes
• Standard 50’ lengths
• 1’, 2’ and 4’ widths.
Foundation Liner
Features
• UV Resistant
• .060” thickness
• Stain, odor and moisture resistant
• Insect and pest resistant
• Shatter resistant
• Energy efficient
• Attractive gray pebbled finish adds value to your property
• Protects basements and crawlspaces from flooding
• Easy to install on both existing buildings and new construction
• Can be installed directly to solid walls or over insulation
• Stays strong and sturdy in any season
• 10 year Limited Warranty
The Best Products, Service, Price & Selection All Under One Brand
Independent Laboratory Test Results
Before Stain Cleaning Test After Stain Cleaning Test
REASON FOR ANALYSIS: Evaluation of the White Glasteel FRP Panel from the viewpoint of overall stain resistance properties as well as resistance to chemical cleaners and high intensity UV light.
EXECUTIVE SUMMARY: The White Glasteel FRP Panel demonstrates good overall stain resistance properties both before and after surface abrasion tests. In addition the White Glasteel FRP Panel demonstrates good resistance to high intensity UV light and general household cleaning chemicals such as bleach, ammonia, alcohol and acetone with no material degradation noted after exposure tests..
UV Resistance: The White Glasteel FRP Panel exhibits no discoloration or other surface degradation after 60-hours of exposure to high intensity UV light.
Chemical Resistance: The White Glasteel FRP Panel surface showed no evidence of material degradation after exposure to household cleaner, ammonia cleaner, bleach (1% solution), alcohol (70% isopropyl) and acetone.
EVALUATION OF FINDINGS:
Stain Resistance Properties: The White Glasteel FRP Panel demonstrates good overall stain resistance properties on the original surface with all stains being removed after cleaning tests. The abraded surface demonstrates generally good stain resistance with only the ink stain remaining visible after cleaning tests. The stain resistance test consists of applying generous amounts of a variety of stains, including red fruit drink, ketchup, mustard and barbecue sauce as well as some very aggressive stains such as blue ink and permanent marker. These stains were applied to the original as received surface and to a surface which was abraded with sandpaper to remove any surface coatings.
The stains were then allowed to set for a period of 48 hours. The stained areas were then cleaned with a variety of cleaning chemicals to determine overall cleanability. The ketchup, fruit drink and barbecue sauce were all easily removed with a typical household cleaner on both the abraded and original surfaces. The mustard and permanent marker did require use of a stronger chemical such as alcohol and acetone to fully remove the stains. It should be noted the blue ink stain was not completely removed on the abraded test surface when using all the listed cleaning chemicals.
All Glasliner FRP Products are Greenguard Certified
Why is Indoor Air Quality Important?
Whether inside a home, school, business or hospital, people expect their indoor environments to be healthy and safe.
Unfortunately, indoor spaces are often filled with potentially harmful pollutants.
Volatile organic compounds (VOCs) are chemicals that are released into the air from everyday furnishings, building materials and products – items like furniture, flooring and cleaners. Once airborne, VOCs can be easily inhaled by building occupants and trigger a number of health problems.
What is GREENGUARD Certification?
Simply put, GREENGUARD Certification ensures that a product is low-emitting. Products carrying the GREENGUARD mark have been independently tested and re-tested to demonstrate that they meet GREENGUARD’s rigorous third-party chemical emissions standards.
GREENGUARD’s standards are based on established emissions criteria used by the U.S.
Environmental Protection Agency (EPA), the State of California, Germany’s Blue Angel Program and reputable public health agencies.
Improving Indoor Air Quality
Benefits of GREENGUARD Certified Products
• Furnishing your building with GREENGUARD
Certified low-emitting products allows you to create a healthier indoor environment by improving the indoor air quality.
• GREENGUARD Certified products meet some of the most stringent chemical emissions requirements in the world. Products have been independetly, scientifically screened for more than 10,000 chemicals, and they are regularly monitored and retested to ensure they comply with GREENGUARD’s standards.
• Selecting third-party certified, independently tested products helps ensure you are choosing healthier products for your building (and the air you breathe).
For more information on creating a healthier indoor environment, go to www.greenguard.org and take the interactive tour on the Consumer page.
285 Industrial Drive Moscow, TN 38057 800-238-5546 Fax: 901-877-1388 www.glasteel.com
U.S. Headquarters & Distribution Centers 2495 N.E. 36th St.
Ft. Worth, TX 76111 817-831-0505 Fax: 817-831-2001
1279 Corporate Center Dr.
Eagan, MN 55121 651-452-0150 Fax: 651-452-0376
Graham / Stabilit Canada, Inc.
104 Maple Ave Inglewood, ON L0N1L0 905-838-2944 Fax: 905-838-3386 www.grahamfrp.com
03/12 D-SA-01 Rev.:00 M0511
WALL & CEILING LINER PANELS
Additional Product Lines Offered by Glasteel
Canada
Scan the QR Code to Access our Website: www.glasteel.com
File details come from the government source that posted it. Updated .