W911SA22B2008 ATTACHMENT 4 - USAMC 160359_Well 24 and 29_PLAN SET.pdf

PDF 3 MB Posted

Attached to
W911SA22B2008 NEW CONTRACT - REPAIR/REPLACE PUMPS AT WELLS 24 & 29 (WO 2748)
Solicitation number
W911SA22B2008
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F O

R T

M c C

Y

S

U

H

A

V E

F O

C

C

O Y

W

I

D I R

E C

T O

R A

E

P

U B

L I

W

R

K S

SHEET

NUMBER:

D w n b y

D e s i g n e d b y

R e v i e w e d b y

D a t e

C k d b y

S u b m i t t e d b y

W o r k

O r d e r

N o

P r o j e c t

N u m b e r

M A

R K

M O

D

R

E Q

U E

D

E S

C R

I P

T I O

N M

A

T E

DPW

FORT MCCOY, WI

SHEET of

X X

X

R e v

F O

C

O Y

W

I S

C O

N S

I N

R E

P A

L

L

A

N

G1

J N

X X

X

J N

C O

V E

R

S

H E

E T

JB

1 5

REPAIR WELL 24

AND 29

Fort McCoy, Wisconsin

SHEET INDEX TABLE

GENERAL NOTES:

1. THE CONTRACTOR IS RESPONSIBLE TO OBTAIN ALL PERMITS, LICENSES AND

CERTIFICATIONS NEEDED TO PERFORM THE WORK AT THE CONTRACTOR'S

EXPENSE.

2. ALL EQUIPMENT INSTALLATIONS MUST BE IN ACCORDANCE WITH THE

MANUFACTURER'S PUBLISHED DATA AND RECOMMENDATIONS.

3. CONTRACTOR MUST PERFORM ALL WORK IN ACCORDANCE WITH THE MOST

RECENT EDITION OF EM 385-1-1 SAFETY AND HEALTH REQUIREMENTS MANUAL

(2014 EDITION)

4. CONTRACTOR SHALL OBTAIN SPECIFIC UTILITY REQUIREMENTS FOR EACH

UTILITY. EACH UTILITY MAY REQUIRE ADDITIONAL ADVANCE NOTIFICATION.

5. CONTRACTOR IS RESPONSIBLE TO OBTAIN UTILITY LOCATES PRIOR TO THE

START OF EXCAVATION OPERATIONS AND MAINTAIN UTILITY MARKINGS DURING

CONSTRUCTION.

6. CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING UTILITIES.

CONTRACTOR IS RESPONSIBLE TO VERIFY ALL EXISTING SITE CONDITIONS.

GOVERNMENT INFORMATION, DATA AND DRAWINGS ARE FOR REFERENCE ONLY,

NOT FOR CONSTRUCTION, AND DO NOT CONTAIN ALL EXISTING UTILITIES AND

SITE CONDITIONS. CONTRACTOR MUST NOT REPLY UPON GOVERNMENT

INFORMATION, DATA AND DRAWINGS AS SUBSTITUTE FOR CONTRACTOR

VERIFICATION.

7. SCALES SHOWN APPLY ONLY WHEN DRAWINGS ARE PRINTED ON 22" X 34"

PAPER. SCALES ARE HALF SIZED WHEN PRINTED ON 11" X 17" PAPER.

8. ALL MATERIALS, LABOR, EQUIPMENT AND WORK MUST BE IN ACCORDANCE WITH

SPECIFICATIONS, STANDARDIZED CONSTRUCTION METHODS AND PRACTICES,

MANUFACTURER'S PUBLISHED DATA AND RECOMMENDATIONS, AND ALL

FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS, STATUES, AND CODES.

9. THE CONTRACTOR MUST PROVIDE WRITTEN NOTIFICATION TO COR WITHIN

THREE DAYS OF DISCOVERING DISCREPANCIES BETWEEN EXISTING SITE

CONDITIONS, DRAWINGS, SPECIFICATIONS, AND CONTRACT DOCUMENTS. THE

CONTRACTOR MUST PROVIDE A WRITTEN REQUEST FOR CLARIFICATION TO

ADDRESS EACH DISCREPANCY.

10. THE GOVERNMENT IS NOT RESPONSIBLE FOR THE CONTRACTOR'S CONSTRUCTION

PRACTICES, MEANS AND METHODS. THE CONTRACTOR MUST PROVIDE A WRITTEN

REQUEST TO COR A MINIMUM OF SEVEN CALENDAR DAYS PRIOR TO THE START OF

CONSTRUCTION FOR APPROVAL OF ANY DEVIATIONS FROM STANDARDIZED

CONSTRUCTION PRACTICES, MEANS AND METHODS WHETHER STATED OR IMPLIED ON

DRAWINGS AND IN SPECIFICATIONS.

11. EQUIPMENT, MATERIALS AND MANUFACTURERS LISTED IN THESE DRAWINGS MAY BE

SUBSTITUTED FOR EQUAL PRODUCTS IN COMPLIANCE WITH SPECIFICATIONS AND

FEDERAL PURCHASING REQUIREMENTS.

NTS

LOCATION MAP

C

U

E

F O

C

O Y

W

I

D I R

E C

T O

R A

P

U B

L

R

K S

SHEET

NUMBER:

D w n b y

D e s i g n e d b y

R e v i e w e d b y

D a t e

C

S u b m i t t e d b y

W o r k

O r d e r

N o

P r o j e c t

N u m b e r

M A

R K

M O

D

R

E Q

U E

E S

C R

I P

T I O

N M

A

T E

DPW

FORT MCCOY, WI

SHEET of

X X

X

R e v

F O

C

O Y

W

I S

C O

N S

I N

R E

P A

L

L

A

G2

J N

X X

X

J N

L O

C A

T I O

N

M

A P

JB

2 5

NTS

LOCATION MAP WELL 24

NTS

LOCATION MAP WELL 29

WELL DATA:

UNIQUE WELL NO: YG656

DRILLER: SAM'S WELL DRILLING INC

DRILLING DATE: DECEMBER 20, 2011

STATIC WATER LEVEL: 12.0'

PUMPING LEVEL: 87.00' @ 300 GPM

PUMP DATA:

CAPACITY: 300 GPM

POWER: 460 VOLTS, 3 PHASE, 60 HZ

SUBMERSIBLE O.D.: 6.0"

DISCHARGE: 4.0"

SERIAL #: 300S300-9-B

STAGES: 9

F O

C

U

E

F O

C

O Y

W

I

D I R

E C

T O

R A

P

U B

L

R

K S

SHEET

NUMBER:

D w n b y

D e s i g n e d b y

R e v i e w e d b y

D a t e

C

S u b m i t t e d b y

W o r k

O r d e r

N o

P r o j e c t

N u m b e r

M A

R K

M O

D

R

E Q

U E

E S

C R

I P

T I O

N M

A

T E

DPW

FORT MCCOY, WI

SHEET of

X X

X

R e v

F O

C

O Y

W

I S

C O

N S

I N

R E

P A

L

L

A

P1

J N

X X

X

J N

W E

L

E

X I S

T I N

G

A

P

O

P O

S E

D

C O

N D

I T

I O

N S

JB

3 5

SUBMERSIBLE CABLE:

SIZE: #8 STANDARD COPPER

GROUND WIRE SIZE: #10

WIRE TYPE: FLAT JACKET

INSULATION TYPE: PVC

NOTES:

1. REMOVE EXISTING PITLESS UNIT AND ADAPTOR.

2. REMOVE EXISTING COULUM PIPE, CHECK VALVE, PUMP & MOTOR FROM

THE WELL.

3. TELEVISE WELL. (PRE-CLEANING)

4. BRUSH CASING AND CLEAN.

5. FOLLOW STEPS IN SPECIFICATION SECTION 33 21 11 WELL

REHABILITATION FOR MECHANICAL AND CHEMICAL REHABILITATION OF

THE WELL

6. TELEVISE WELL. (POST-CLEANING)

7. PERFORM TEST PUMPING.

8. INSTALL NEW DOWNHOLE EQUIPMENT (PUMP, MOTOR, COLUMN

PIPE,CHECK VALVE) ALONG WITH A NEW PITLESS ADAPTOR O-RING.

9. CONDUCT BACTERIOLOGICAL SAMPLING AND CLEAN UP.

NTS

WELL 24 EXISTING CONDITIONS

1/P1

EXISTING: WELL 24

NTS

PROPOSED IMPROVEMENTS TO WELL 24, SEE SPECIFICATIONS

2/P1

PITLESS ADAPTER:

TYPE: DROP-IN

SPOOL PIECE SIZE 17.5" X 17"

DROP PIPE DIAMTER:: 6.0"

MOTOR DATA:

SEE SPECIFICATION 33 28 30

WELL DATA:

UNIQUE WELL NO: YO929

DRILLER: MUNICIPAL WELL AND PUMP

DRILLING DATE: DECEMBER 12, 2015

STATIC WATER LEVEL: 21.0'

PUMPING LEVEL: 69.00' @ 502 GPM

PUMP DATA:

CAPACITY: 400 GPM

POWER: 460 VOLTS, 3 PHASE, 60 HZ

SUBMERSIBLE O.D.: 6.125"

DISCHARGE: 6"

MODEL #: 385S500-6

STAGES: 6

NOTES:

1. DATA IS BASED ON INFORMATION PROVIDED DURING THE LAST PUMP

REMOVAL AND T.V. REPORT, JUNE 18, 2020.

F O

C

U

E

F O

C

O Y

W

I

D I R

E C

T O

R A

P

U B

L

R

K S

SHEET

NUMBER:

D w n b y

D e s i g n e d b y

R e v i e w e d b y

D a t e

C

S u b m i t t e d b y

W o r k

O r d e r

N o

P r o j e c t

N u m b e r

M A

R K

M O

D

R

E Q

U E

E S

C R

I P

T I O

N M

A

T E

DPW

FORT MCCOY, WI

SHEET of

X X

X

R e v

F O

C

O Y

W

I S

C O

N S

I N

R E

P A

L

L

A

P2

J N

X X

X

J N

W E

E

X I S

T I N

G

A

P

O

P O

S E

D

C O

N D

I T

I O

N S

JB

4 5

NOTES:

1. REMOVE EXISTING PITLESS UNIT AND ADAPTER.

2. REMOVE EXISTING COLUMN PIPE, CHECK VALVE, PUMP & MOTOR FROM

THE WELL.

3. TELEVISE WELL. (PRE-CLEANING)

4. BRUSH CASING AND CLEAN.

5. FOLLOW STEPS IN SPECIFICATION 33 21 11 WELL REHABILITATION, FOR

THE STEPS FOR REHABILITATION AND TESTING ON THE WELL.

6. NOTE: DEPENDING ON THE RESULTS OF #5; REVIEW ALTERNATE STEPS

WITH COR FOR INSTALLATION OF A LINER SCREEN & SCREEN/PACK

DEVELOPMENT AS OUTLINED IN SECTION "33 21 11 WELL REHABILITATION,

WELL 29".

7. TELEVISE WELL. (POST-CLEANING & DEVELOPMENT)

8. INSTALL NEW DOWNHOLE EQUIPMENT (PUMP, MOTOR, COLUMN PIPE,

CHECK VALVE) ALONG WITH A NEW PITLESS ADAPTOR O-RING.

9. CONDUCT BACTERIOLOGICAL SAMPLING AND CLEAN UP.

EXISTING: WELL 29 SUBMERSIBLE CABLE:

SIZE: #4 STANDARD COPPER

GROUND WIRE SIZE: #10

WIRE TYPE: FLAT JACKET

INSULATION TYPE: PVC

PITLESS ADAPTER: NO INFORMATION

MOTOR DATA:

SEE SPECIFICATION 33 28 30

SETTING: 168'

NTS

WELL 29 EXISTING CONDITIONS

1/P2

NTS

PROPOSED IMPROVEMENTS TO WELL 29, SEE SPECIFICATIONS

2/P2

0'

202'

SANDSTONE

16" PERMANENT

INNER CASING

83' BOTTOM OF CASING

15" NOMINAL OPEN

BOREHOLE

BLASTING WIRE

WELL CAP

BLAST BOTTOM 20' WITH

FOUR SHOTS AT A MAX OF

10LBS PER SHOT

0'

SAND

12'

F O

C

U

E

F O

C

O Y

W

I

D I R

E C

T O

R A

P

U B

L

R

K S

SHEET

NUMBER:

D w n b y

D e s i g n e d b y

R e v i e w e d b y

D a t e

C

S u b m i t t e d b y

W o r k

O r d e r

N o

P r o j e c t

N u m b e r

M A

R K

M O

D

R

E Q

U E

E S

C R

I P

T I O

N M

A

T E

DPW

FORT MCCOY, WI

SHEET of

X X

X

R e v

F O

C

O Y

W

I S

C O

N S

I N

R E

P A

L

L

A

P3

J N

X X

X

J N

L I N

R

E E

N B

L A

S T

I N

G

D

E T

A I L

JB

5 5

PROTECT EXISTING CASING PER

DNR CODE, DURING BLASTING,

WITH 100' MINIMUM PROTECTIVE

ZONE

20'

NTS

WELL 29 LINER SCREEN

1/P3

NTS

WELL 29 BLASTING DETAIL

2/P3

NOTES:

1. SEE SPECIFICATION 33 21 11 WELL REHABILITATION

NOTES:

1. SEE SPECIFICATION 33 21 11 WELL REHABILITATION

2. ALTERNATE BID ITEM FOR WELL 29