W911SA-17-B-0021_Attachment_Two_Drawings.pdf
PDF 1 MB Posted
- Attached to
- Construct Leach Fields Federal contract opportunity
- Solicitation number
- W911SA-17-B-0021
About this file
W911SA-17-B-0021 Attachment Two Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W911SA-17-B-0021_Preliminary_Bid_Opening_Results.pdf | ||
| W911SA-17-B-0021_Attachment_Four_Wage_Determination_4.12.17.docx | DOCX document | |
| W911SA-17-B-0021_Solicitation_Amendment_Two.docx | DOCX document | |
| W911SA-17-B-0021_Solicitation_Amendment_One.docx | DOCX document | |
| W911SA-17-B-0021_Attachment_One_AT_OPSEC.pdf | ||
| W911SA-17-B-0021_Attachment_Five_SF_24.pdf | ||
| W911SA-17-B-0021_Attachment_Four_Wage_Determination.docx | DOCX document | |
| W911SA-17-B-0021_Attachment_Three_Specifications.pdf | ||
| W911SA-17-B-0021_Final_Solicitation.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fort McCoy, Wisconsin
CONSTRUCT LEACH FIELDS
AT EPW2 AT
FORT MCCOY
SHEET INDEX
Sheet Number Sheet Title
1 COVER SHEET
2 HOLDING TANKS
3 POWTS SITE PLAN
POWTS TANKAGE
PLAN VIEW
6 END VIEW
FINAL GRADE TO DIVERT ALL SURFACE
WATER AWAY FROM TANK OPENINGS
MANHOLE RISER & HATCH
{per SPS 384.25 (7) & (8)}
(w/approved locking device)
PLACARD TO READ:
"KITCHEN WASTE"
APPROVED ENCLOSURE FOR
HIGH WATER ALARM
CONNECTIONS AND VISUAL &
AUDIBLE SIGNAL
Panel to read:
EPW2 HOLDING TANK
HIGH LEVEL ALARM
IF ALARM OR RED LIGHT IS
ON CALL DPW HELP DESK
(608) 388-4357
MINIMUM OF 3" SUITABLE BEDDING
BENEATH BOTTOM OF TANK
HOLDING TANKS
KITCHEN WASTEWATER
4" ASTM 3034 BUILDING
SEWER @ 18" PER FOOT
6" CROSS-OVER PIPE
SCHEDULE 40 PVC
"FLOAT TREE"
1-1/2" SCH 40 PVC
ANCHORED TO
MANHOLE
Holding tank design based on -----------------------WIESER W8000** Alarm design based on --------------------------------SJE RHOMBUS ** Alarm design based on------------------------------- SignalMaster® SPDT ** Float switch type ------------------------------------- MECHANICAL
** BASIS OF DESIGN FOR INFORMATIONAL PURPOSES ONLY-
ALL APPROVED EQUALS ARE TO BE ACCEPTED
HOLDING TANK CAPACITIES
Reserve capacity above alarm float----- 12"------1446.64 gallons Alarm float above bottom of tank---------531
2"-----6538.77 gallons
HOLDING TANK DIMENSIONS
Length---------------------- 2381
8" O.D.
Width----------------------- 1421
8" O.D.
Liquid Level--------------- 651
2" Gallons per inch--------- 122.22 Actual capacity-----------8000.0 gallons
ANCHORING REQUIRED PER SPS 383.43 (8) (g)
4" BUILDING SEWER
per SPS 382.30(11)(c)
INVERT = 987.75'
Depth of invert may change depending on overlength of building sewer and required depth of bury
Tank manufacturer to provide identification label on MH cover of each holding tank to read:
"KITCHEN WASTE"
PROVIDE BOLLARDS AT OUTER
EXTENT OF HOLDING TANKS
BUILDING SEWER MUST COMPLY
WITH SPS 382.30 WAC (11)(C)
LOCATION OF WELLS MUST COMPLY
WITH WDNR CHS. NR 811 & 812
BENCHMARK ELEVATION = 997.84'
- GRADE AT BASE OF STAKE
LOCATION OF SOIL BORINGS
LOCATION OF SOIL TEST PITS
NO APPARENT SPS 393.43 SETBACKS
ELEVATION STAKE
(990.13' @ GRADE)
ELEVATION STAKE
(997.84' @ GRADE)
TWO-COMPARTMENT
SEPTIC/SEPTIC TANK
INVERT = 985.50'
18 NUMBER OF LEACHING CHAMBERS (per cell)
16 NUMBER OF CELLS
288 TOTAL NUMBER OF LEACHING CHAMBERS (all cells)
HOLDING TANKS CONNECTED AT BOTTOM
WITH 6"
SCH 40 PVC PIPE.
SIGNAGE TO READ:
EPW2 HOLDING TANK
HIGH WATER LEVEL ALARM
IF RED LIGHT IS ON
CALL DPW HELP DESK
(608) 388-4357
Depth of bury is estimated and may vary depending on length and depth of bury of building sewer
ALL BUILDING SEWER AND FORCEMAIN
SUPPLY SHALL BE INSTALL @ 1
8" PER FOOT
MINIMUM PITCH AND COMPLY WITH FROST
PROTECTION REQUIRED PER
SPS 382.30(11)(C)2.a.a.
BURIED 2" PVC
WASTEWATER PIPING
Placard to be posted at outlet of dose tank and not greater than 75' with last placard posting at location of distribution box.
Install silt fence around tanks and leach fields if excavations left open longer than 7 days
DOSE TANK
Duplexing on-demand effluent pumps
10GPM @ 22.5' THD
BUFFER = Bottom of tank to pump off = 6" (296.76 gallons)
DOSE = pump off to pump on = 10" (494.60 gallons) LAG = pump on to lag on = 4" = (197.84 gallons)
HWA = lag on to HWA = 2" = (98.92 gallons) RESERVE = 28" = (1384.88 gallons)
SEPTIC TANK
effluent filter (rated @ 10,000 GPD)
SEPTIC TANK DOSE TANK
45.09 GPI 22.26 GPI
BAFFLES
4" BUILDING SEWER
per SPS 382.30(11)(c)
INVERT = 984.92'
Depth of invert may change depending on overlength of building sewer and required depth of bury
FINAL GRADE TO DIVERT ALL SURFACE
WATER AWAY FROM TANK OPENINGS
4" BUILDING SEWER
per SPS 382.30(11)(c)
INVERT = 984.92'
PERMANENT HANDLE TO
TERMINATE <1" FROM MANHOLE
COVER TO PREVENT FILTER
CARTRIDGE FROM FLOATING
MANHOLE RISER & COVER
{per SPS 384.25 (7) & (8)}
(w/approved locking device)
4" MIN. SCH 40 PVC TANK
VENT (w/approved cap)
LOCATED 12" ABOVE GRADE
BUILDING SEWER FROM LAUNDRY & SHOWER FACILITIES
INSTALL @ 18" PER FOOT MINIMUM PITCH
FROST PROTECTION REQUIRED PER
SPS 382.30(11)(C)2.a.a.
MANHOLE RISER & COVER
{per SPS 384.25 (7) & (8)}
(w/approved locking device)
24"
MH
Tank manufacturer to provide identification label on hatch cover
"DOSE TANK"
Tank manufacturer to provide identification label on hatch cover
"SEPTIC TANK OUTLET
FILTER ACCESS"
PLACARD ON MANHOLE
COVER TO READ:
EPW2 HOLDING TANK
HIGH LEVEL ALARM
IF RED LIGHT IS ON
CALL DPW HELP DESK
(608) 388-4357
BOTTOM OF TANK
ELEV = 976.53'
MANHOLE COVER
ELEV = 991.60'
BOTTOM OF TANK
ELEV = 979.50'
MANHOLE COVER
ELEV = 991.60'
49.46 GPI
Tank manufacturer to provide identification label on hatch cover
"SEPTIC TANK INLET"
PROVIDE BOLLARDS AT OUTER
EXTENT OF HOLDING TANKS
DIMENSIONED PLAN VIEW & CROSS SECTION
4" OBSERVATION PIPE
(typical installation in end cap of chamber)
A
B
C
D
E
F
G
H
150' - 2" SCH 40 pvc FORCEMAIN @ 18" per foot
(drains back to dose tank via weep hole after each dose) per SPS 382.30(11)(c)2.a.a.
DISTRIBUITON BOX (invert = 995.00')
150' - 4" SCH 3034 PVC
@ 18" per foot (drains from distribution box to chambers)
18 NUMBER OF LEACHING CHAMBERS (per cell)
16 NUMBER OF CELLS
288 TOTAL NUMBER OF LEACHING CHAMBERS (all cells)
SYSTEM ELEVATION (BOTTOM OF EACH CELL)
A 994.50' E 993.50' B 994.50' F 993.50' C 994.00' G 993.00' D 994.00' H 993.00'
BOLLARD (typical) to be installed atour outer extent of absorption cells
CR
OS
S
SE
CT
IO
N
OF
C
HA
MB
ER
S
A
S
YS
TE
M
EL
EV
AT
IO
N (B
OT
TO
M
OF
E
AC
H
CE
LL
A
4.5 0'
E
3.5 0'
B
4.5 0'
F
3.5 0'
C
4.0 0'
G
3.0 0'
D
4.0 0'
H
3.0 0'
DI
ST
RI
BU
IT
ON
B
OX
(o ut let in ve rts
5.0 0')
~1
4"
S
CH
P
VC
1 8" p er fo ot
(d ra in s f ro m di st rib ut io n bo x t o ch am be rs ) B
C D
E F
G H
0'
- 2 " S
CH
P
VC
F
OR
CE
MA
IN
1 8" p er fo ot (d ra in s b ac k t o do se ta nk af te r e ac h pu m pi ng cy cle
FI
NI
SH
G
RA
DE
(s oi l t o pr om ot e pl an t g ro wt h)
4" S
CH
p vc
O
BS
ER
VA
TI
ON
P
IP
E (w ith re m ov ab le wa te rti gh t c ap o r v en t c ap if
" a bo ve fi ni sh g ra de
(m us t h av e a n op en b ot to m th at te rm in at es
4" ab ov e sy st em el ev at io n an d be p ro pe rly an ch or ed
(s cr ew s o r c ol lar s a re ac ce pt ab le m et ho ds
IN
FI
LT
RA
TO
R
CH
AM
BE
R
- O
PE
N
BO
TT
OM
A
RE
A
.1
SQ
FT
IN
FI
LT
RA
TI
VE
S
UR
FA
CE
P
ER
C
HA
MB
ER
B
AS
ED
O
N
EI
SA
R
AT
IN
G
.0
SQ
FT
QU
IC
K 4 S
TA
ND
AR
D
EN
D
CA
PS
P
ER
P
AI
R
EI
SA
R
AT
IN
G
4.6 S
QF
T
FI
NI
SH
G
RA
DE
(s oi l t o pr om ot e pl an t g ro wt h)
UN
EX
CA
VA
TE
D
AR
EA
A
DJ
AC
EN
T
AN
D
BE
NE
AT
H
TR
EN
CH
ES
| 1 |
| 2 |
| 3 |
| 4 |
| 5 |
| 6 |