This document provides the results of an asbestos survey and inventory for Building 2049 at Fort Drum, along with details of a related federal contract opportunity to perform asbestos abatement and heavy metal cleanup services. The survey found asbestos-containing materials including silver paint associated with roof insulation, ceiling insulation around the hangar perimeter, and the EPDM roof. It also identified other regulated materials throughout the building. The federal contract opportunity is solicitation number W911S2-22-U-CLEA from the Department of the Army to provide all resources necessary to perform cleaning of heavy metals including hexavalent chromium and asbestos abatement in Building 2049 at Wheeler-Sack Air Field in accordance with the attached performance work statement and contract terms.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 2049

Applies to Buildings: 2049 Only

CAT Code Description: 14112 AVN UNIT OPS

Summary of Findings

ACM Present: Yes ORMs Present: Yes Explosives Screening Done: No If Yes, was it present?

Describe:

NA

Construction Details:

Building Size: 32,540 SF as report by base personnel Date Constructed: Not Reported Number of Floors:

(not including Basement)

Basement Present: No Framing: Steel Foundation Type: Slab Foundation Material: Concrete Roof Style: Flat/Slightly Pitched Roof Material: EPDM Exterior Wall Composition: Sheet Metal

Building Observations:

Current Use: Helicopter Maintenance Hangar Building Condition: Intact Other:

Building 2049 – ACM & ORM Summary

Material Description Notes Quantity

Asbestos-Containing Materials (ACMs)

Silver Paint associated with Isocyanurate Insulation Roof 5000 SF

White Ceiling Insulation Hangar Perimeter 600 SF

EPDM Roof Roof 12,000 SF

Fire Doors 76 EA

Other Regulated Materials (ORMs)

Light Fixtures – Interior & Exterior

Standard 8

Metal Halide, Sodium, etc. 23

4 ft Fluorescent Light Fixtures 150

4 Tubes each Fixture 600

1 Non-PCB Ballasts each Fixture 150

1 PCB Ballasts each Fixture 150

4 ft Fluorescent Light Fixtures 13

1 Tubes each Fixture 13

1 Non-PCB Ballasts each Fixture 13

4 ft Fluorescent Light Fixtures 65

2 Tubes each Fixture 130

1 Non-PCB Ballasts each Fixture 65

Electrical Panels / Fuse Boxes 32 Emergency Lights with Battery(ies) 42 Exit Signs: Illuminated 36 Exit Signs: Reflective 3 Fire Extinguishers 18 Gas Meters 1 Hot Water Heaters 2 HVAC Units: Small Units 1 HVAC Units: Window Units 1 Smoke Detectors 3 Thermostats 7 Transformers: Pad-Mounted Mechanical Room 2 Transformers: Pole-Mounted 3 Water Coolers 2 Other: Acid Storage Cabinets 1 Other: Flammable Storage Cabinet 4 Other: Air Compressor 3 Other: Wall Mounted Heaters 51

Building 2049 – ACM Sample Inventory

Sample Number Material Description Sample

Location Laboratory Analysis

Material Extent Condition Friability

2049-01 Sealer (White) Hanger Thermal Insulation = ND Sealer = ND

2049-02 Sealer (White) Hanger Thermal Insulation = ND Sealer = ND

2049-03 Sealer (Red) Hanger Sealer = ND

2049-04 Sealer (Red) Hanger Sealer = ND

2049-05 Drywall / Joint Compound Room 8 Drywall Material = ND Joint Compound = ND

2049-06 Drywall / Joint Compound Room 17 Drywall Material = ND Joint Compound = ND

2049-07 Sealer (Grey) Hanger Sealer = ND

2049-08 Sealer (Grey) Hanger Sealer = ND

2049-09 Cove Base (Grey) / Mastic (Tan) 2nd Floor Corridor

Cove Base = ND Mastic = ND

2049-10 Cove Base (Grey) / Mastic (Tan) Hanger Cove Base = ND Mastic = ND

2049-11 Mastic (Black) on Paper Room 8 Paper / Tar Backing = ND Thermal Insulation = ND

2049-12 Mastic (Black) on Paper Room 17 Paper / Tar Backing = ND Thermal Insulation = ND

2049-13 Floor Tile (Oatmeal) / Mastic (Yellow)

2nd Floor Corridor

Floor Tile = ND Yellow Mastic = ND

2049-14 Floor Tile (Oatmeal) / Mastic (Yellow) Room 9 Floor Tile = ND

Yellow Mastic = ND

2049-15 Cove Base (Black) / Mastic (Tan) 2nd Floor Corridor

Cove Base = ND Mastic = ND

2049-16 Cove Base (Black) / Mastic (Tan) Room 9 Cove Base = ND Mastic = ND

2049-17 Floor Tile (Grey) / Mastic (Yellow)

2nd Floor Corridor

Floor Tile = ND Yellow Mastic = ND

2049-18 Floor Tile (Grey) / Mastic (Yellow) Room 9A Floor Tile = ND

Yellow Mastic = ND

2049-19 Sink Coating (White) Room 21 Sink Undercoating = ND

2049-20 Sink Coating (White) Room 21 Sink Undercoating = ND

2049-21 Formica Wallboard / Mastic (Tan) Room 21 Bath Fiberglass Panel = ND Mastic = ND

2049-22 Formica Wallboard / Mastic (Tan) Room 21 Bath Fiberglass Panel = ND Mastic = ND

2049-23 Ceramic Wall Tile / Mastic (Tan) / Grout (White) Room 29

Ceramic Tile = ND Grout = ND Mastic = ND

2049-24 Ceramic Wall Tile / Mastic (Tan) / Grout (White) Room 31

Ceramic Tile = ND Grout = ND Mastic = ND

Sample Number Material Description Sample

Location Laboratory Analysis

Material Extent Condition Friability

2049-101 Isocyanurate Insulation (Black and Yellow) / Drywall / Pitch (Black)

Roof

Tars = ND Membrane = ND

Felts = ND Foam Insulation = ND

Wood = ND Drywall Material = ND

5,000 SF G NF1

2049-102 Isocyanurate Insulation (Black and Yellow) / Drywall / Pitch (Black)

Roof

Silver Paint = 2% Ch Tars = ND Felts = ND

Foam Insulation = ND Wood = ND

Drywall Material = ND

5,000 SF G NF1

2049-103 Black Sealer Roof Vents Sealer = ND

2049-104 Black Sealer Roof Vents Sealer = ND

-- Fire Doors Assumed Positive 76 EA G F

-- White Ceiling Insulation Hangar Perimeter Assumed Positive 600 SF G F

-- EPDM Roof Roof Assumed Positive 12,000 SF G NF2 SF = Square Feet Am = Amosite G = Good F = Friable ACM LF = Linear Feet Ch = Chrysotile D = Damaged NF1 = Category I Non-Friable ACM EA = Each Cr = Crocidolite SD = Significantly Damaged NF2 = Category II Non-Friable ACM ND = None Detected PS = Positive Stop

Building 2049 – Photographs

Building Exterior Building Interior

Building Interior Roof

S. MCCUTCHEON

10-18-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 2049

Sample Location Map

J. SMITH

1st Floor

32A

11 05

10-18-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 2049

Sample Location Map

J. SMITH

12 17

19 20 21 22

2nd Floor

10-18-2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 2049

Sample Location Map

J. SMITH

Roof

12/12/2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 2049

ACM Location Map

J. SMITH

Assumed ACM FIRE DOORS Not Shown

Assumed Asbestos-Containing FIRE DOORS

1st Floor

12/12/2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 2049

ACM Location Map

J. SMITH

2nd Floor

Assumed ACM White Ceiling Insulation

Assumed Asbestos-Containing WHITE CEILING INSULATION Assumed Asbestos-Containing FIRE DOORS

Assumed ACM FIRE DOORS Not Shown

12/12/2011

FORT DRUM

Pre-Demolition Survey

Figure Drawn

Title:

Checked

Project:

Not To Scale

BUILDING 2049

ACM Location Map

J. SMITH

Roof

ACM Silver Paint on Isocyanurate Insulation

Assumed EPDM Roof

Asbestos-Containing SILVER PAINT ON ISOCYANURATE INSULATION Assumed Asbestos-Containing EPDM ROOF

File details come from the government source that posted it. Updated .