Questions_Answers June 11 2024_1.pdf
PDF 693 KB Posted
- Attached to
- BFVS A3 Slip Ring Tester
- Solicitation number
- W911RQ-24-R-0117
About this file
This document is a set of Questions and Answers related to a federal contract opportunity for a BFVS A3 Slip Ring Tester.
The key details are:
- The solicitation requires a capacitance test, but the performance document does not define this test. Additional details confirm the capacitance test refers to figures called out in drawing notes 12 and 13.
- Functional shock and vibration testing, as well as EMI/EMC testing in an anechoic chamber, are only required for first article inspection, which is not part of this procurement. The government clarifies they do not need first article testing capabilities.
- The associated NAICS code is 334515 A3 Slip Ring Tester with a 750 employee size standard. The contract will be for a period of 10 months or less from the award date.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A3 Slip Ring Tester COMBINED SYNOPSIS Solicitation_2.docx | DOCX document | |
| A3 Slip Ring Tester COMBINED SYNOPSIS Solicitation FINAL.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions & Answers 6/11/2024
1. QUESTION: The synopsis/solicitation document states capacitance as a required test whereas the performance document does not have a definition of a capacitance test. Please provide additional details regarding the capacitance test.
ANSWER, The capacitance test we are referring to must be the figures called out on the drawing in notes 12 and 13.
2. QUESTION : Please verify that functional shock and vibration are included in the scope of this proposal. According to Table III in the performance document these tests are only performed during first article inspection where as additional tests required for first article inspection were not specifically listed in the synopsis/solicitation document.
ANSWER, We do not need first article testing capabilities or control test capabilities.
3. QUESTION : Please verify that electromagnetic combability and EMI/EMC testing are included in the scope of this proposal. According to Table III in the performance document these tests are only performed during first article inspection and are performed in an anechoic chamber.
ANSWER, We do not need first article testing capabilities or control test capabilities.
NOTE: We are not designing and manufacturing the part, so we are not obligated to do any first article testing.
File details come from the government source that posted it. Updated .