Appendix A - DEVCOM SC Monti and Building 4 Visual Art Project Overview Specifications_03182025.pdf
PDF 5 MB Posted
- Solicitation number
- W911QY25QAP08
About this file
This document is a detailed Visual Arts Project Overview and Specifications for the U.S. Army Combat Capabilities Development Command (DEVCOM) Soldier Center, focusing on visual arts and wayfinding signage for the SFC Jared C. Monti Research Facility and Building 4. The project encompasses five specific locations: the research facility's second and third floors, and four areas within Building 4's first floor (Timeline Wall, Patent Wall, Innovation Wall, and North Entrance Directory).
The specifications provide comprehensive technical requirements for each visual art installation, including precise measurements, production methods, material types, and mounting techniques. Key specifications include digital printing on various materials like styrene and vinyl, with strict color accuracy standards (delta E value no greater than 3), minimum 100 dots per inch resolution, and requirements for durability, scuff resistance, and consistent finishing. The project utilizes a specific color palette following U.S. Army brand guidelines, with various mounting methods such as nondestructive adhesive and magnetic attachments, and is designed to be consistent with existing artwork in the facility.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Not Approved for Public Release Unclassified
Not Approved for Public Release Unclassified
U.S. ARMY COMBAT CAPABILITIES
DEVELOPMENT COMMAND
SOLDIER CENTER
CDO
DEVCOM SC
Unclassified C GuoQuan Liang
SFC Jared C. Monti Research Facility & Building 4 Visual Arts Project Overview & Specifications 16 APR 2025
Not Approved for Public Release
Not Approved For Public Release Unclassified
PROJECT OVERVIEW
• The goal of this project is to provide visual arts and wayfinding signage for the newly constructed SFC Jared C. Monti Research Facility and newly renovated Building 4 Director’s wing.
• The project consists of Five (5) locations:
1. SFC Monti Research Facility Phase 3 - Second & Third Floor
2. Building 4 1st Floor Timeline Wall
3. Building 4 1st Floor Patent Wall
4. Building 4 1st Floor Innovation Wall
5. Building 4 1st Floor North Entrance Directory
• All measurements provided are in inches
Not Approved for Public Release
Not Approved For Public Release Unclassified
OVERALL SPECIFICATIONS
• Each visual art product shall follow the overall specifications below unless otherwise defined on the product specifications.
• Color Accuracy
– All digital print shall be produced using color specification provided by the Government design file using hex and/or
RGB code.
– Color different shall be perceptible through close observation or better, delta E value no greater than 3.
• Resolution & Clarity
– Digital print shall be produced with minimum 100 dots per inch.
– Images and texts shall be clear and visible within 3-meter viewing distance.
• Durability & Stability
– Final product shall be free of visible defects including but not limited to delamination, bubbling, and cracking.
– The product shall be stable for any handling required for installation and durable for use in standard office environment.
– The product shall have minimum scuff resistance from human touch.
– The product shall be colorfast and does not rub off onto another material when touched.
Not Approved for Public Release
Not Approved For Public Release Unclassified
SFC Monti Research Facility Phase 3 - Second & Third Floor
Not Approved for Public Release
Not Approved For Public Release Unclassified
FLOOR 2 – WALL “G”
Quantity:
2 Small 4 Large
Measurements:
Small: 16W x 16H Large: 16W x 48H
Production:
Digital print on styrene
Design File Type:
.psd file
Material Type:
0.040 White Styrene with
1/8” non glare acrylic glazing
Finish:
Glossy with no or reduced glare
Wall Material:
Drywall
Mounting Method:
Nondestructive adhesive
Not Approved for Public Release
Not Approved For Public Release Unclassified
FLOOR 2 – WALL “J”
Quantity:
Measurements:
545W x 98H
Production:
Digital print on vinyl
Design File Type:
.ai file
Material Type:
≥5mil combined vinyl wallpaer
Finish:
Matte
Wall Material:
Drywall
Not Approved for Public Release
Not Approved For Public Release Unclassified
FLOOR 2 – WALL “N”
Quantity:
Measurements:
32W x 41H
Production:
Digital print on styrene
Design File Type:
.png file
Material Type:
0.040 White Styrene with
1/8” non glare acrylic glazing
Finish:
Glossy with no or reduced glare
Wall Material:
Drywall
Not Approved for Public Release
Not Approved For Public Release Unclassified
FLOOR 3 – WALL “C”
Quantity:
Measurements:
166W x 116H
Production:
Digital print on vinyl
Design File Type:
.psb file
Material Type:
≥4mil vinyl
Finish:
Matte
Wall Material:
Drywall
Not Approved for Public Release
Not Approved For Public Release
Building 4 1st Floor Timeline Wall
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 TIMELINE WALL
• Description
– Forty (40) Boards, each board is 20 W x 24 H
– Two rows of 20, overall installed dimension 400 W x 48 H
• Production
– Digital print on magnetic backed sheets
– Magnetize existing wall with magnetic paint and color match existing wall color
• Design file type
– .ai file
• Material type
– Digital print on 0.040 styrene with magnetic backing and non glare acrylic glazing
– Magnetic ferrous paint
– Standard paint with sheen and color match to existing painted surface
• Finish
– Glossy with no or reduced glare
• Mounting
– Magnetic
• Wall Material
– Drywall
Not Approved for Public Release
Not Approved For Public Release
Building 4 1st Floor Patent Wall
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 PATENT WALL
• Description
– One (1) silver colored magnetic board, 230 W x 46 H
– Forty-five (45) plaques, 6 W x 8 H
• Production
– Silver Board: Magnetize Sintra backing board with wrap edges
– Lettering: Digital print on Sintra
– Plaque: Digital print on Sintra
• Design file type
– .indd and.ai file
• Material type
– Silver Board: 6mm Sintra with front magnetic paper and brushed aluminum silver vinyl wrap
– Lettering: digital print on 6mm Sintra
– Plaque: digital print on 6mm Sintra
• Mounting
– Silver Board: Surface mount with standoffs, 1” Diameter x ¾” Aluminum standoff anchor to drywall.
– Lettering: Nondestructive adhesive or magnetic attachment to board
– Plaque: Magnetic on silver board
• Finish
– Silver Board: metallic wash
– Lettering & Plaque: Matte
– Cinder block
Not Approved for Public Release
Not Approved For Public Release
BUILDING 4 PATENT WALL - SILVER
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 PATENT PLAQUE
• magnetic backing, just like with the Memoriam so they can be rearranged as more are added
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 PATENT WALL
• Product style, color, and finish shall be consistent with existing artworks in the same area
Not Approved for Public Release
Not Approved For Public Release
Building 4 1st Floor Innovation Wall
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 INNOVATION WALL
• Description
– One (1) black colored board, 147 W x 46 H
– Lettering and logos
• Production
– Black Board: Digital print on Sintra
– Lettering: Digital print on Sintra
• Design file type
– .indd and .ai file
• Material type
– Black Board: digital print on 6mm Sintra with wrap edges
– Lettering: digital print 6mm Sintra
• Finish
– Matte
• Mounting
– Black Board: Surface mount with standoffs, 1” Diameter x ¾” Aluminum standoff anchor to drywall.
– Lettering: Nondestructive adhesive directly on board
– Cinder block
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 PATENT WALL - BLACK
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 PATENT WALL
• Product style, color, and finish shall be consistent with existing artworks in the same area
Not Approved for Public Release
Not Approved For Public Release
Building 4 1st Floor North Entrance
Not Approved for Public Release
Not Approved For Public Release Unclassified
BUILDING 4 NORTH ENTRANCE
• Description
– One (1) directory signage at building 4 north entrance, facing the building entrance.
– Overall dimension 35.5 W x 40 H
• Production
– Digital print on PVC for floor number sign 18W x 20H
– Directory lettering and arrows by cut vinyl
• Design file type
– .ai file
• Material type
– 6 mm Sintra
– ≥4mil vinyl
• Finish
– Matte
• Mounting
– Hidden mounting / Non-destructive adhesive
– Cinder Block
Not Approved for Public Release
Not Approved For Public Release
Additional Information
Not Approved for Public Release
Not Approved For Public Release
US ARMY COLOR PALETTE SPECIFICATIONS
Not Approved for Public Release
Not Approved For Public Release
MONTI COLOR SWATCHES
| U.S. ARMY COMBAT CAPABILITIES�DEVELOPMENT COMMAND�SOLDIER CENTER |
| Project overview |
| Overall specifications |
| SFC Monti Research Facility Phase 3 - Second & Third Floor |
| Floor 2 – Wall “G” |
| Floor 2 – Wall “J” |
| Floor 2 – Wall “N” |
| Floor 3 – Wall “C” |
| Building 4 1st Floor Timeline Wall |
| Building 4 Timeline Wall |
| Building 4 1st Floor Patent Wall |
| Building 4 Patent Wall |
| Building 4 Patent Wall - Silver |
| Building 4 Patent Plaque |
| Building 4 Patent Wall |
| Building 4 1st Floor Innovation Wall |
| Building 4 Innovation Wall |
| Building 4 Patent Wall - Black |
| Building 4 Patent Wall |
| Building 4 1st Floor North Entrance |
| Building 4 North Entrance |
| Additional Information |
| US Army color palette specifications |
| Monti color swatches |
File details come from the government source that posted it. Updated .