List of Salient Characteristics - Vacuum Systems - FINAL.docx

DOCX document 31 KB Posted

Attached to
Vacuum Pump Systems
Solicitation number
W911QY24R0012
Issued by

About this file

This document is a Request for Quotation (RFQ) for a firm-fixed-price contract for four (4) positive displacement vacuum pump systems to support the United States Army Combat Capabilities Development Command - Soldier Center (DEVCOM-SC) Joint Biological Agent Decontamination System (JBADS) Program. The vacuum pump systems are required to have specific technical specifications, including a minimum 100 ACFM pumping speed, 6 HP motor, and 1.25" inlet/1" outlet size. This is a 100% small business set-aside acquisition with a NAICS code of 333914 - Measuring, Dispensing, and Other Pumping Equipment Manufacturing. Proposals are due by July 10, 2024 and will be evaluated based on technical capability and price. The Department of the Army, Army Contracting Command-Aberdeen Proving Ground (ACC-APG) Natick Division is the contracting organization. Delivery is required as soon as possible to the DEVCOM Soldier Center in Natick, MA.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

List of Salient Characteristics

1. Background: The United States Army Combat Capabilities Development Command - Soldier Center (DEVCOM-SC) Protection Systems Engineering Team/Joint Biological Agent Decontamination System (JBADS) Program needs to purchase four (4) positive displacement vacuum pump systems. These large-scale vacuum pumps are for system tear down and packaging. Their purpose is to remove air from multiple insulation sections of the JBADS liner system simultaneously to ensure proper storage.

2. Requirements:

a. General Specifications: This requirement is for large scale vacuum pump systems for system tear down and packaging.

b. Specific Specifications: Purchase of four (4) positive displacement vacuum pump systems in accordance with the following specifications:

· Non-return valve incorporated into the inlet flange is required to prevent air from back flowing into the vacuum chamber when the pump is turned off.

· Air-cooled, requiring no water.

· Dry-running, no sealing or lubricating oil is needed in the pumping chamber.

· Nominal pumping speed: minimum 100 Actual Cubic Feet per Minute (ACFM)

· Motor size: minimum 6 horsepower

· Nominal motor speed: minimum 3600 Revolutions Per Minute (RPM)

· Approximate weight: as light as possible

· Inlet/ outlet size: Ideally 1.25” inlet and 1” outlet

3. Other Direct Costs (ODCs): N/A

4. Deliverables: The contractor shall deliver four (4) vacuum systems in accordance with section 2 above.

5. Invoicing: The contractor shall bill in WAWF after DEVCOM-SC confirms receipt of the deliverables.

6. Delivery Date: The contractor shall provide delivery within 2-3 months from receipt of order.

7. Ship to DODAAC and Shipping Address: W56YHX - U.S. Army DEVCOM Soldier Center, 10 General Greene Ave, BLDG 5 S-145, Natick MA, 01760-5000.