Amendment 0001 to W911PT-16-Q-0137.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_16-Q-0137-0002.pdf | ||
| SK-1_-_Revised_Layout.pdf | ||
| 5BL011_SOW_Install_OSHA_Railings_Rev2.docx | DOCX document | |
| Wage_Determination_NY160002_07-29-2016_NY2.txt | TXT text file | |
| Site_Visit_Announcement.doc | DOC document | |
| W911PT-16-Q-0137.pdf | ||
| Drawing_Attachments.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W16H1F605702EF
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
Additional Information from the August 9, 2016, site visit is added per attached.
1. CONTRACT ID CODE PAGE OF PAGES
1 3
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 12-Aug-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W911PT-16-Q-0137
X 9B. DATED (SEE ITEM 11)
02-Aug-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
12-Aug-2016
CODE
ARMY CONTRACTING COMMAND-WARREN (WVA)
ATTN: CCTA-HDW/BLDG 10
1 BUFFINGTON STREET
WATERVLIET NY 12189-4000
W911PT 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
ronald.a.ascher.civ@mail.milEMAIL:(518) 266-4643TEL:
RONALD ASCHER / CONTRACT SPECIALIST
W911PT-16-Q-0137
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been added by full text:
ADDENDUM TO SOW 5BL011
Clarifications based on the August 9th, 2016, site visit are as follows:
1) Coordination for moving items on/under mezzanine and in warehouse space will be handled by the Government.
2) The contractor shall furnish and install 1/2" plywood over the existing flooring surface on the east and west mezzanine. The plywood need only to be screwed down. Fasteners shall be sized appropriately and intended for such an application.
3) The breaker in the electrical panel is a General Electric TEY.
4) In order to comply with code, the new transformer will need to be placed under the northeast stairwell in lieu of the utility closet, Room 114 (see attached for new location). This is approximately 75 feet from the utility closet. An access hatch will also be required next to where the conduit passes through the wall.
5) The contractor shall submit shop drawings detailing all aspects of the lighting control system to include but not limited to fixture types, locations, control zones, wiring diagrams, etc. for review and approval prior to release for fabrication. Lighting control system drawings shall include electric riser diagrams and show circuiting to panels. Layout of fixtures shall take into account sprinklers and location of fire alarm components. To the best extent possible develop layouts that work around collisions.
6) The contractor shall NOT permanently affix luminaires to any part of the cast iron structure as it is considered historical. All fixtures shall be installed using mounting clamps or cable ties. Fixtures and Unistrut for upper mezzanine(s) may be clamped to the cast iron beam. Location and mounting method shall be marked on the shop drawings.
7) Wiring shall be installed in either MC or EMT conduit. Conduit shall be ¾" and strapped and supported per NEC code. Flexible wiring may be used for areas where conduit is not feasible.
8) The contractor shall install new 3 way switch circuits at the North and South double doors. Switches shall operate fixtures for the center bay, upper mezzanine, and lower mezzanine. Contractor shall also install switches at the fire door and office door on the upper mezzanine level. At least one fixture at each of the ingress/egress points shall operate via a motion or infrared detector for nighttime safety.
W911PT-16-Q-0137
9) It is acceptable to use handrail brackets instead of welded continuous handrails so long as the handrail design meets loads of OSHA.
10) The office on the west mezzanine shall remain, the walls on the east mezzanine shall be removed.
(End of Summary of Changes)