W911N2-24-R-0001-0002.pdf

PDF 305 KB Posted

Attached to
Fire Equipment Maintenance Federal contract opportunity
Solicitation number
W911N2-24-R-0001
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This is an amendment to a solicitation for fire equipment maintenance services. The amendment provides answers to nine questions submitted by potential offerors, extending the response due date from March 8th to March 18th, 2024 at 4:00 PM. The services required include testing and inspection of six pumps with capacities ranging from 90 to 1,500 GPM, as well as 15,000 feet of hose, 180 feet of ground ladders, 30 nozzles, and 15 appliances. Spare equipment in storage may also require testing. Inspections are required for a 2003 medium duty fire truck equipped with a 320 gallon tank, 90GPM pump, and 20 gallon foam proportioning system. The incumbent contractor is listed as Glick Fire Equipment. The solicitation was issued by the Department of the Army Materiel Command Contracting Command located at Redstone Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to Fire Equipment Maintenance, newest first.
File Type Posted
W911N2-24-R-0001-0003.pdf PDF
conformed W911N2-24-R-0001 23 May 2024.pdf PDF
W911N2-24-R-0001-0001.pdf PDF
W911N2-24-R-0001.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LAURA BUEHLER

717-267-9617

LETTERKENNY CONTRACTING OFFICE - ACC

1 OVERCASH AVENUE CCAM- DSL BLDG 2S

CHAMBERSBURG PA 17201

W25G1Q3216R001

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provi ded herei n, all t erms and condit ions of t he document refere nced in Item 9A or 10A, as heretofore change d, remai ns unchanged and in ful l force and effect .

15A. NAME AND TIT LE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

ST ANDARD FORM 30 (Rev. 10-83) Prescr ibed by GSA

FAR (48 CFR) 53.243

Purpose of this amendment is to answ er questions submitted and extend the closing date to 18 March 2024, 4:00 PM. See Summary of Changes.

1. CO NTRACT ID CODE P AGE OF P AGES

Y 1 3

16A. NAME AND T ITLE OF CONTRACTING OFFICER (Type or print)

16C. DAT E SIGNED

BY 05-Mar-2024

16B. UNITED ST AT ES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contract ing Officer )(Signature of person authorized t o sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, Count y, Stat e and Zip Code) X W911N224R0001

X 9B. DAT ED (SEE IT EM 11)

30-Jan-2024

10B. DAT ED (SEE IT EM 13)

9A. AMENDMENT OF SOLICITAT ION NO.

11. THIS IT EM ONLY APPLIES T O AMENDMENT S OF SOLICITATIONS

X The above numbered soli cit ati on i s amended as set forth in It em 14. The hour and date specified for rece ipt of Offer X is ext ended, is not extended.

Offer must acknowl edge rece ipt of t his amendment pri or to the hour and date specified in the sol ici tat ion or as amended by one of t he fol lowing methods:

(a) By compl eti ng Items 8 and 15, and returning 1 copi es of the amendment ; (b) By acknowledgi ng recei pt of thi s a mendment on each copy of t he offer submit ted;

or (c) By s epara te let ter or t elegram whi ch i ncludes a refe rence t o t he s olic ita tion and amendment numbers . FA ILURE OF YOU R A CKNOWLEDGMENT TO BE RECEIVED AT TH E P LACE D ESIGNATED FOR TH E RECEIPT OF OFFERS P RIO R TO THE HOUR AN D DATE SP ECIFIED MA Y RESULT IN

REJECTIO N OF YOUR OFFER. If by vir tue of thi s amendment you desire t o change an offer already submit ted, s uch c hange ma y be made by t ele gram or let ter, provided each t elegram or l ett er makes reference to the sol ici tat ion and this amendment , and is re ceived prior to the openi ng hour and dat e speci fi ed.

12. ACCOUNTING AND APPROPRIATION DAT A (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORT H IN ITEM 14 ARE MADE IN THE

CONT RACT ORDER NO. IN ITEM 10A.

B. T HE ABOVE NUMBERED CONT RACT /ORDER IS MODIFIED T O REFLECT THE ADMINIST RATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORT H IN ITEM 14, PURSUANT TO T HE AUTHORITY OF FAR 43.103(B).

C. T HIS SUPPLEMENT AL AGREEMENT IS ENT ERED INTO PURSUANT TO AUTHORITY OF:

D. OT HER (Specify type of modification and authorit y)

E. IMPORTANT: Contract or is not, is required to sign this document and return copies t o the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/cont ract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/ MODIFICATION NO. 5. P ROJECT NO .(If appli cable)

6. ISSUED BY

3. EFFECTIVE DATE

05-Mar-2024

CODE

LETTERKENNY ARMY DEPOT

LETTERKENNY CONTRACTING OFFICE - ACC

1 OVERCASH AVENUE CCAM-DSL BLDG 2S

CHAM BERSBURG PA 17201- 4150

W911N2 7. AD MINISTERED BY (If other t han item 6)

4. REQUISITION/PU RCHASE REQ. NO.

CODE W911N2

FACILITY CODECODE

EMAIL:TEL:

W911N224R0001

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

QUESTIONS AND ANSWERS

Q1: Are there any aerial ladders and if so how many?

A1: No ladders. This statement is in accordance with NFPA 1911

Q2: Are there any foam trucks and if so how many?

A2: No foam trucks. This statement is in accordance with NFPA 1911

Q3: How many pumps are there to test and what is the GPM of each pump.

A3(a): 6 pumps A3(b): 1,500 GPM (3); 1,000 GPM (1); 150 GPM (1); 90 GPM (1)

Q4: Are there any crash trucks and if so how many?

A4: No crash trucks.

Q5: Is the expected schedule to be October and if not, when?

A5: Yes, or 12 months from the last inspection. All inspections were completed between October and December 2023.

Q6: Is there an incumbent, and if so, who?

A6: Glick Fire Equipment

Q7: Please provide anticipated total feet of hose, total feet of ground ladders, total number of Nozzles and Total number of appliances.

A7: Hose – 15,000’ Ladders – 180’ Nozzles – 30 Appliances – 15

Q8: Are there are any spares of the above in storage that will also need to be tested?

A8: Yes

W911N224R0001

Q9: Please provide more information on the apparatus Special Unit 13 2003 E-One 1FDAW57F83EA00454 FD-503. What is the apparatus and what inspections does it require.

A9: Medium duty on a F550 chassis, that is equipped with 320 Gal tank, 90GPM pump and 20 Gal foam proportioning system.

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 08-Mar-2024 01:00 PM to 18-Mar-2024 04:00 PM.

(End of Summary of Changes)

File details come from the government source that posted it. Updated .