Text version
REVISION
SHEET
SHEET REVISION RECORD
NEXT ASSY USED ON
APPLICATION
B
DWG NO.CAGE CODESIZE
SHEETSCALEDATE
APPROVED
REVIEWED
CHECKED
DRAWN
MATERIAL:
FRACTIONS DECIMALS ANGLES
TOLERANCES ON:
DIMENSIONS ARE IN INCHES
UNLESS OTHERWISE SPECIFIED:
PARTS LIST
NOTEDESCRIPTION
NOMENCLATURE OR
IDENTIFYING NO.
PART NO. OR
REQD
QTY
NO.
FIND
APPROVEDDATEDESCRIPTIONLTR
0NDM7
LETTERKENNY ARMY DEPOT
CHAMBERSBURG, PA. 17201
REV
REVISIONS
VIP
PANEL, VACUUM INSULATED, 14X28,
MOBILE INTEGRATED REMAINS
COLLECTION SYSTEM
891-11002
LEAD-FP-5127 -SAFETY
CATHY MARTIN
10 SEP 2018 1 : 8 1 OF 1
MIRCS-
C. MARTIN10 SEP 18RELEASED FOR PRODUCTION-
X.X 0.06
± X.XX 0.03
X.XXX 0.015
± 2°± 1/32
NOTES:
VACUUM INSULATED PANEL (VIP) THICKNESS SHALL BE 0.650"
+/-0.0625"
THERMAL CONDUCTIVITY SHALL NOT EXCEED 0.020
BTU-INCH/FT2-HR-F PER ASTM C518
PANEL PERFORMANCE DEGRADATION SHALL NOT EXCEED 2.8%
PER YEAR
VIP SHALL BE RATED FOR TEMPERATURE EXPOSURE OF 200
DEGREES F MINIMUM.
1.
2.
3.
4.
14.000 +/-0.125
28.000 +/-0.125
DISTRIBUTION STATEMENT A
THIS DOCUMENT IS APPROVED FOR PUBLIC RELEASE: DISTRIBUTION IS UNLIMITED
File details come from the government source that posted it. Updated .